Shenzhen Sunspring Electronics Co., Ltd.
Keyboard
OJWCG107C
Violet Wang
Test Report WPT
ACOUSTMAX INTERNATIONAL CO., LTD MNRR360 2AAIN-MNRR360 2AAINMNRR360 mnrr360
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 23 Pages, 1.88MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6241405Page 1 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC FCC TEST REPORT For ACOUSTMAX INTERNATIONAL CO., LTD ROCKIN ROLLER 360 Test Model: MNRR360 Additional Model No.: Please Refer to Page 6 Prepared for Address : ACOUSTMAX INTERNATIONAL CO., LTD : Unit D16/F Cheuk Nang Plaza 250 Hennessy Road WanchaiHongKong. China Prepared by Address Tel Fax Web Mail : Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park : Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China : (+86)755-82591330 : (+86)755-82591332 : www.LCS-cert.com : [email protected] Date of receipt of test sample Number of tested samples Serial number Date of Test Date of Report : October 13, 2022 :2 : A092622177-1, A092622177-2 : October 13, 2022 ~ October 26, 2022 : October 27, 2022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 2 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC FCC TEST REPORT FCC CFR 47 PART 15C Report Reference No. .....................: LCSA092622177EC Date Of Issue...................................... : October 27, 2022 Testing Laboratory Name.............. : Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Address................................................ : Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China : Full application of Harmonised standards Testing Location/ Procedure............ Partial application of Harmonised standards Other standard testing method Applicant's Name............................. : ACOUSTMAX INTERNATIONAL CO., LTD Address................................................ : Unit D16/F Cheuk Nang Plaza 250 Hennessy Road WanchaiHongKong. China Test Specification Standard.............................................. : FCC CFR 47 PART 15C Test Report Form No......................... : LCSEMC-1.0 TRF Originator.................................... : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF......................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description..................... : ROCKIN ROLLER 360 Trade Mark.......................................... : Test Model........................................... : MNRR360 Power Supply...................................... : Input: AC 100-240V, 50/60Hz, 100W USB Output: DC 5V, 2.1A Battery: DC 12V, 9Ah Result ..................................................: Positive Compiled by: Supervised by: Approved by: Kevin Huang/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC FCC TEST REPORT Test Report No. : LCSA092622177EC October 27, 2022 Date of issue Test Model.............................. : MNRR360 EUT......................................... : ROCKIN ROLLER 360 Applicant............................... Address.................................. Telephone............................... Fax.......................................... : ACOUSTMAX INTERNATIONAL CO., LTD : Unit D16/F Cheuk Nang Plaza 250 Hennessy Road WanchaiHongKong. China :/ :/ Manufacturer........................ Address................................... Telephone............................... Fax.......................................... : NINGBO POLINATA ELECTRONICS CO., LTD. : Xinrui Road #9, Longxing CITY, Zhejiang 315111 Village, Yinzhou District, NINGBO :/ :/ Factory................................... Address................................... Telephone............................... Fax.......................................... : NINGBO POLINATA ELECTRONICS CO., LTD. : Xinrui Road #9, Longxing CITY, Zhejiang 315111 Village, Yinzhou District, NINGBO :/ :/ Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC Revision History Report Version 000 Issue Date October 27, 2022 Revision Content Initial Issue Revised By --- Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................ 6 1.1 Description of Device (EUT) ........................................................................................................................6 1.2 Support equipment List ................................................................................................................................ 6 1.3 External I/O Cable .........................................................................................................................................6 1.4 Description of Test Facility .......................................................................................................................... 7 1.5 Statement of the Measurement Uncertainty ............................................................................................. 8 1.6 Measurement Uncertainty ........................................................................................................................... 8 1.7 Description of Test Modes ...........................................................................................................................8 2. TEST METHODOLOGY ...................................................................................................................... 9 2.1 EUT Configuration ........................................................................................................................................ 9 2.2 EUT Exercise .................................................................................................................................................9 2.3 General Test Procedures .............................................................................................................................9 2.3.1 Conducted Emissions ............................................................................................................................... 9 2.3.2 Radiated Emissions ...................................................................................................................................9 3. SYSTEM TEST CONFIGURATION .................................................................................................10 3.1 Justification .................................................................................................................................................. 10 3.2 EUT Exercise Software .............................................................................................................................. 10 3.3 Special Accessories ................................................................................................................................... 10 3.4 Block Diagram/Schematics ....................................................................................................................... 10 3.5 Equipment Modifications ............................................................................................................................10 3.6 Test Setup .................................................................................................................................................... 10 4. SUMMARY OF TEST EQUIPMENT ................................................................................................11 5. SUMMARY OF TEST RESULT ....................................................................................................... 12 6. POWER LINE CONDUCTED MEASUREMENT ...........................................................................13 7. RADIATED EMISSION MEASUREMENT ..................................................................................... 16 7.1. Block Diagram of Test Setup ................................................................................................................... 16 7.2. Radiated Emission Limit ........................................................................................................................... 17 7.3. EUT Configuration on Measurement ...................................................................................................... 17 7.4. Operating Condition of EUT ..................................................................................................................... 17 7.5. Measuring Setting ......................................................................................................................................18 7.6. Test Procedure ...........................................................................................................................................18 7.7. Test Results ................................................................................................................................................19 9. PHOTOGRAPHS OF TEST SETUP ............................................................................................... 23 10. EXTERNAL PHOTOGRAPHS OF THE EUT .............................................................................. 23 11. INTERNAL PHOTOGRAPHS OF THE EUT ............................................................................... 23 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 1. GENERAL INFORMATION 1.1 Description of Device (EUT) EUT : ROCKIN ROLLER 360 Test Model : MNRR360 Additional Model No. Model Declaration Power Supply Hardware Version Software Version Bluetooth : MNRR360-X, MNRR360-C, MNRR360-EU, MNRR360 Plus, MNRR360C, MNRR360X, MNRR360XC, MNRR360EU, MNRR360-X Plus, MNRR300, MNRR300-C, MNRR300-X, MNRR360PRO, MNRR360MAX : PCB board, structure and internal of these model(s) are the same, So no additional models were tested : Input: AC 100-240V, 50/60Hz, 100W USB Output: DC 5V, 2.1A Battery: DC 12V, 9Ah :/ :/ : Frequency Range : 2402MHz ~ 2480MHz Channel Number Channel Spacing Modulation Type Bluetooth Version : 79 channels for Bluetooth V5.0(DSS) 40 channels for Bluetooth V5.0(DTS) : 1MHz for Bluetooth V5.0(DSS) 2MHz for Bluetooth V5.0(DTS) : GFSK, /4-DQPSK for Bluetooth V5.0(DSS) GFSK for Bluetooth V5.0(DTS) : V5.0 Antenna Description Wireless Charging : BT Antenna: PCB Antenna, -0.58dBi(Max.) BLE Antenna: PCB Antenna, 3.64dBi(Max.) : Operating Frequency : 111~205KHz Modulation Type : ASK Antenna Type : Coil Antenna, 0dBi(Max.) Maximum Rated Power of WPT : 10W 1.2 Support equipment List Manufacturer Description Model HONOR Mobile phone V30Pro Note: Auxiliary equipment is provided by the laboratory. Serial Number Certificate 66B0219C25014679 FCC 1.3 External I/O Cable I/O Port Description Power Port AUX Input Port USB Port Quantity 1 1 1 Cable N/A N/A N/A Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 1.4 Description of Test Facility NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024 CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912 The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 1.5 Statement of the Measurement Uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 4 "Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements" and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 1.6 Measurement Uncertainty Test Item Radiation Uncertainty : Conduction Uncertainty : Power disturbance : Frequency Range 9KHz~30MHz 30MHz~200MHz 200MHz~1000MHz 1GHz~26.5GHz 26.5GHz~40GHz 150kHz~30MHz 30MHz~300MHz Uncertainty 3.10dB 2.96dB 3.10dB 3.80dB 3.90dB 1.63dB 1.60dB Note (1) (1) (1) (1) (1) (1) (1) (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. 1.7 Description of Test Modes Equipment under test was operated during the measurement under the following conditions: Charging and communication mode Modulation Type: ASK Test Modes Mode 1 EUT+ Mobile Phone (Battery Status: <1%) Mode 2 EUT+ Mobile Phone (Battery Status: <50%) Mode 3 EUT + Mobile Phone (Battery Status: 100%) Record Pre-tested Pre-tested Note: All test modes were pre-tested, but we only recorded the worst case in this report. For AC conducted emission, pre-test at both AC 120V/60Hz and AC 240V/50Hz, recorded worst case; For AC conducted emission, pre-test at AC charge from power adapter modes, recorded worst case. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with ANSI C63.10-2013, FCC CFR PART 15C 15.207 and DA 00-705. 2.1 EUT Configuration The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 2.2 EUT Exercise The EUT was operated in the normal operating mode for Hopping Numbers and Dwell Time test and a continuous transmits mode for other tests. According to its specifications, the EUT must comply with the requirements of the Section 15.207 under the FCC Rules Part 15 Subpart C. 2.3 General Test Procedures 2.3.1 Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes. 2.3.2 Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane below 1GHz and 1.5 m above ground plane above 1GHz. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10-2013 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 23 FCC ID: 2AAIN-MNRR360 3. SYSTEM TEST CONFIGURATION Report No.: LCSA092622177EC 3.1 Justification The system was configured for testing in a normal condition. 3.2 EUT Exercise Software N/A. 3.3 Special Accessories N/A. 3.4 Block Diagram/Schematics Please refer to the related document. 3.5 Equipment Modifications Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT. 3.6 Test Setup Please refer to the test setup photo. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 4. SUMMARY OF TEST EQUIPMENT Item Equipment Manufacturer 1 MXA Signal Analyzer 2 RS SPECTRUM ANALYZER 3 3m Semi Anechoic Chamber 4 Positioning Controller Agilent R&S SIDT FRANKONIA Max-Full 5 EMI Test Software AUDIX 6 EMI Test Receiver R&S 7 Active Loop Antenna SCHWARZBECK 8 By-log Antenna SCHWARZBECK 9 EMI Test Receiver R&S 10 Artificial Mains R&S 11 10dB Attenuator SCHWARZBECK 12 EMI Test Software Farad 13 Exposure Level Tester Narda 14 B-Field Probe Narda Model No. N9020A FSP40 SAC-3M MF7802BS E3 ESR 7 FMZB 1519B VULB9163 ESPI ENV216 MTS-IMP-136 EZ ELT-400 ELT-400 Serial No. MY49100040 100503 Cal Date Due Date 2022-06-16 2023-06-15 2021-11-16 2022-11-15 03CH03-HY 2022-06-16 2023-06-15 MF780208586 / 101181 00005 9163-470 101940 101288 261115-001-0032 / N-0713 M-1154 N/A N/A 2022-06-16 2021-08-29 2021-09-12 2022-08-17 2022-06-16 2022-06-16 N/A 2021-11-18 2021-11-18 N/A N/A 2023-06-15 2024-08-28 2024-09-11 2023-08-16 2023-06-15 2023-06-15 N/A 2022-11-17 2022-11-17 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 23 FCC ID: 2AAIN-MNRR360 5. SUMMARY OF TEST RESULT Report No.: LCSA092622177EC FCC Rules §15.207(a) §15.209 Description of Test AC Conducted Emissions Radiated Spurious Emissions Test Sample Sample 1 Sample 1 Remark: The measurement uncertainty is not included in the test result. N/A Not Applicable!!! Result Compliant Compliant Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 6. POWER LINE CONDUCTED MEASUREMENT 6.1. Block Diagram of Test Setup 6.2. Standard Applicable According to §15.207: For all the consumer devices which is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range are listed as follows: Frequency Range (MHz) 0.15 to 0.50 0.50 to 5 5 to 30 Quasi-peak 66 to 56 56 60 Limits (dBV) Average 56 to 46 46 50 * Decreasing linearly with the logarithm of the frequency 6.3 Test Results PASS The test data please refer to following page. Temperature 23.5 Test Engineer Taylor Hu Humidity Configurations 53.2% Transmit Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Line Page 14 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Neutral Page 15 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC ***Note: Pre-scan all modes and recorded the worst case results in this report. Measurement = Reading + Correct, Margin = Measurement Limit. Correct Factor=Lisn Factor+Cable Factor Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 16 of 23 FCC ID: 2AAIN-MNRR360 7. RADIATED EMISSION MEASUREMENT 7.1. Block Diagram of Test Setup Report No.: LCSA092622177EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 17 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 7.2. Radiated Emission Limit 15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the frequency bands listed below: MHz MHz MHz 0.090-0.110 \1\ 0.495-0.505 2.1735-2.1905 4.125-4.128 4.17725-4.17775 4.20725-4.20775 6.215-6.218 6.26775-6.26825 6.31175-6.31225 8.291-8.294 8.362-8.366 8.37625-8.38675 8.41425-8.41475 12.29-12.293. 12.51975-12.52025 12.57675-12.57725 13.36-13.41 16.42-16.423 16.69475-16.69525 16.80425-16.80475 25.5-25.67 37.5-38.25 73-74.6 74.8-75.2 108-121.94 123-138 149.9-150.05 156.52475-156.52525 156.7-156.9 162.0125-167.17 167.72-173.2 240-285 322-335.4 399.9-410 608-614 960-1240 1300-1427 1435-1626 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2690-2900 3260-3267 3332-3339 3345.8-3358 3600-4400 \1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz. \2\ Above 38.6 GHz 4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5 9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5 (\2\) According to §15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequencies (MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength (microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance (meters) 300 30 30 3 3 3 3 7.3. EUT Configuration on Measurement The following equipment are installed on Radiated Emission Measurement to meet the commission requirements and operating regulations in a manner which tends to maximize its emission characteristics in normal application. 7.4. Operating Condition of EUT (1) Setup the EUT as shown in Section 7.1. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 18 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 7.5. Measuring Setting The following table is the setting of spectrum analyzer and receiver. Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9kHz~150kHz / RB 200Hz for QP/Average 150kHz~30MHz / RB 9kHz for QP/Average 30MHz~1000MHz / RB 100kHz for QP 7.6. Test Procedure 1) Sequence of testing 9 kHz to 30 MHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used. --- If the EUT is a floor standing device, it is placed on the ground. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions. --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0° to 315° using 45° steps. --- The antenna height is 1 meter. --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions Final measurement: --- Identified emissions during the premeasurement the software maximizes by rotating the turntable position (0° to 360°) and by rotating the elevation axes (0° to 360°). --- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector. --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 19 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 2) Sequence of testing 30 MHz to 1 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation. Premeasurement: --- The turntable rotates from 0° to 315° using 45° steps. --- The antenna is polarized vertical and horizontal. --- The antenna height changes from 1 to 3 meter. --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions. Final measurement: --- The final measurement will be performed with minimum the six highest peaks. --- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. --- The final measurement will be done with QP detector with an EMI receiver. --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. 7.7. Test Results PASS. Only report the worst test data mode 1 in test report; The test data please refer to following page: Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 20 of 23 0.009 MHz 30 MHz Temperature Test Engineer 0 degree FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 23.8 Taylor Hu Humidity Configurations 52.5% Transmit Remark: 1). Measured at antenna position 0 degree and 90 degree, recorded worst case at 0 degree. 2). Level = Reading + Factor, Margin = LevelLimit, Factor = Antenna Factor + Cable Loss - Preamp Factor. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 21 of 23 Below 1GHz Temperature Test Engineer Horizontal FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 23.8 Taylor Hu Humidity Configurations 52.1% Transmit Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Vertical Page 22 of 23 FCC ID: 2AAIN-MNRR360 Report No.: LCSA092622177EC 1). Emission level (dBuV/m) = 20 log Emission level (uV/m). 2). Level = Reading + Factor, Margin = LevelLimit, Factor = Antenna Factor + Cable Loss - Preamp Factor. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 23 of 23 FCC ID: 2AAIN-MNRR360 9. PHOTOGRAPHS OF TEST SETUP Report No.: LCSA092622177EC Please refer to separated files for Test Setup Photos of the EUT. 10. EXTERNAL PHOTOGRAPHS OF THE EUT Please refer to separated files for External Photos of the EUT. 11. INTERNAL PHOTOGRAPHS OF THE EUT Please refer to separated files for Internal Photos of the EUT. -------------THE END OF REPORT------------- Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity
Related FCC IDs:
- 2AAIN-MNRR360 - ACOUSTMAX INTERNATIONAL CO., LTD ROCKIN ROLLER 360 [-MNRR360] WPS 文字 PDFsharp 1.50.5147 (www sharp.com)