TempStar GPX Approval

• Delime/manual wash switch • Hi-limit thermostat and low water protection • Vent fan control • Top mounted controls for ease of operation • Adjustable bullet feet • Front dress panel • External gas booster heater - Capable of minimum 70˚F (38.9˚C) degree temperature rise - Recirculates water through stainless steel coils in ...

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 2 Pages, 211.77KB

Document DEVICE REPORTTempstar gpx
TempStar® GPX

TempStar® GPX

Project Item Quantity CSI Section 11400 Approval Date

Models
TempStar® GPX

Standard Features

Mandatory Specs

· Multi-cycle timer (Extra Heavy, Heavy, Medium, Normal)
· Specially designed stainless steel nozzles provide superior cleaning action
· 17-1/4" (438 mm) door opening accepts 18" (457 mm) trays
· Interchangeable wash/rinse arms screw out for simple cleanup
· Auto ll/auto-start
· Door switch
· Delime/manual wash switch
· Hi-limit thermostat and low water protection
· Vent fan control
· Top mounted controls for ease of operation
· Adjustable bullet feet
· Front dress panel
· External gas booster heater - Capable of minimum 70°F (38.9°C) degree temperature rise - Recirculates water through stainless steel coils in wash tank to maintain 150°F (66°C) degree minimum temperature
· Self-draining stainless steel pump
· Uses standard 20" X 20" (508 mm X 508 mm) racks

Specify incoming water temperature Specify how far booster will be placed from unit Specify altitude for proper booster size
Options
1/2" Pressure Regulator Drain Quench System Scaltrol Water Hammer Arrestor Flanged Feet False Panel Door Interlock
Accessories
36-Compartment Rack 4-1/8" tall (105 mm) 5-5/8" tall (143 mm) 7" tall (178 mm)
Combination Rack Peg Rack

· Detergent/rinse additive signal connection fuse box

Specifications
Uses 1.0 gallon (4 liters) of 180°F (82°C) water per rack Total automatic cycle - 58 seconds 57 racks per hour 3/4 hp wash pump motor Single point connections for all utilities

Field convertible from straight through to corner and vice versa Durable stainless steel construction
www.jacksonwws.com

TempStar® GPX

4 [102mm] C

434 [122mm]

4 [102mm]
20-3/8" (517.5mm)

2541 [642mm] 32 [813mm]
24-1/2" (622.3mm)

17 [434mm]

6541 [1657mm]

C

76 [1930mm]

17 [434mm]

6034 [1540mm]

Alternate Flue Location

4" (102 mm) Vent Adapter

TPRV

Water Outlet

24 -5/8" (625.5mm)

Water Water Gas Inlet Outlet Inlet

Water Inlet Gas Inlet

34 [863mm]

A

D

LEGEND A - DRAIN 1 1/2" NPT B - WATER INLET 1/2" NPT C - ELECTRICAL CONNECTION D - OUTLET TO BOOSTER
HEATER 3/4" NPT E - INLET FROM BOOSTER
HEATER 3/4" NPT
All vertical dimensions are +/- 1/2" due to adjustable bullet feet.

E 1 [25mm]

1441 [361mm]
321 [92mm] 1034 [274mm]

1841 [466mm] 5 [127mm]

B
1921 [497mm] E
441 [110mm] 13 [328mm]

MODEL NO. TempStar® GPX

MACHINE DIMENSIONS

HEIGHT

WIDTH

64-1/2" (1638 mm)

25-1/4" (641 mm)

DEPTH
25-1/4" (641 mm)

DRAIN HEIGHT
14-1/4" (362 mm)

SHIPPING INFORMATION

WEIGHT CLASS

CUBE

400 lbs (181 kg)

92.5

65 cu. ft.

HEIGHT WIDTH DEPTH

79"

33"

43"

(2007 mm) (838 mm) (1092 mm)

DIMENSION REQUIREMENTS Wall Clearance (Minimum) Standard Table Height Inside Clearance

4" (102 mm) 34" (864 mm) 17-1/4" (438 mm)

OPERATING CAPACITY
Racks per Hour
OPERATING CYCLE (seconds) Normal Medium Heavy Extra Heavy

Normal Medium Heavy Extra Heavy

57

29

19

11

Wash 45 103 163 283

Rinse 11 11 11 11

Dwell 2 2 2 2

Total Cycle 58 116 176 294

OPERATING TEMPERATURES Wash (Minimum) Rinse (Minimum)

150°F (66°C) 180°F (82°C)

WASH PUMP Wash Pump Motor Recirculation Motor Wash Pump Capacity (GPM)
HOW TO SPECIFY: TempStar® GPX

3/4 hp 1-1/2 hp 150 gal (1022 L)

GAS REQUIREMENTS
Natural Gas (inches-water column) LP Propane Gas (inches-water column) Gas Connection (NPT) Flue Adapter (Diameter) Gas Booster Capacity (BTU) Input Output

Maximum 10.5 (267 mm) 13.0 (330 mm)

WATER REQUIREMENTS Incoming Water Temperature Wash Tank Capacity Flow Pressure (PSI) Gallons per Hour Gallons per Rack Waterline Size (IPS Min.) Drainline Size (IPS Min. Inches)

APPROXIMATE TOTAL LOAD AMPS

115V/60HZ/1PH 208V/60HZ/1PH 230V/60HZ/1PH

Minimum 5.0 (127 mm) 11.0 (292 mm)
1/2" 4" (102 mm)
55,000 46,000
110°F (43°C) 8 gal (30 L)
15-25 57.0 1.0 1/2" 1-1/2"
AMPS 13.2 6.6 6.6

Jackson WWS, Inc.
Shipping Address: 6209 North U.S. Highway 25E, Gray, KY 40734 Mailing Address: P.O.Box 1060, Barbourville, KY 40906 Telephone: 888-800-5672 · Fax: 606-523-1799 Email: [email protected] 07610-002-66-61C [11/03/15]

www.jacksonwws.com

We reserve the right to change speci cations in this bulletin without incurring any obligation for equipment previously or subsequently sold.

