File Info : application/pdf, 18 Pages, 1.08MB
Document DEVICE REPORTSD1220AUUCV - Geothermal Condo Unit Geothermal/Water Source Heat Pump Commercial 1.5 - 3.5 Tons Submittal Data English Language/IP Units SD1220AU 09/10 Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Model Nomenclature 1-2 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21-22 23 UC V 023 T L 0 0 0 C A N N 2 1 N 1 0 SS A Model Type UC = Versatec Ultra Condo Cabinet Configuration V = Vertical Unit Capacity 018 023 031 041 1 Vintage A = Current Non-Standard Option Details SS = Standard Option Drain Pan Options 0 = Composite Drain Pan Cabinet 0 = Unpainted, 1 in. MERV 4, Filter Rail 1 = Painted, 1 in. MERV 4, Filter Rail Discharge Configuration T = Top Future Use N = None Air Configuration L = Left R = Right Air Coil/Insulation Options 1 = FormiShield/Extended Range 4 = No Coating/Standard Range Voltage 0 = 208-230/60/1 2 = 265/60/1 Hot Water Generation Option 0 = No Hot Water Generation 2 = Hot Water Generation w/o pump Blower Option 0 = PSC Blower Coax C = Copper N = Cupronickel Controls Option 2 = Versatec Microprocessor Water Control N = None Future Use N = None Sound Kit A = None B = Sound Kit NOTE: 1 UCV041 not available in 265/60/1 All Versatec Ultra Series UCV product is safety listed under UL1995 thru ETL and performance listed with AHRI in accordance with standard 13256-1. The Versatec Ultra Series UCV is also Energy Star rated. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 2 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz AHRI/ISO 13256-1 Performance Ratings PSC Motor AHRI/ASHRAE/ISO 13256-1 English (IP) Units Flow Rate Model Water Loop Heat Pump Cooling EWT 86°F Heating EWT 68°F Ground Water Heat Pump Cooling EWT 59°F Heating EWT 50°F gpm cfm Capacity EER Capacity Btuh Btuh/W Btuh COP Capacity EER Capacity Btuh Btuh/W Btuh COP 018 5.0 600 17,600 14.6 21,000 4.7 20,600 23.5 17,500 4.0 023 6.0 800 22,000 13.8 27,000 4.5 26,400 21.0 22,300 3.9 031 8.0 1000 29,000 14.0 34,600 4.5 32,900 20.5 28,300 3.9 041 11.0 1300 39,000 13.0 45,000 4.0 44,500 19.0 36,000 3.5 Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature Heating capacities based upon 68°F DB, 59°F WB entering air temperature All ratings based upon 208V operation Ground Loop Heat Pump Cooling EWT 77°F Heating EWT 32°F Capacity EER Capacity Btuh Btuh/W Btuh COP 18,500 17.0 13,700 3.5 24,000 15.6 17,500 3.2 29,500 15.6 22,800 3.2 41,000 14.9 29,000 2.9 Energy Star Rated yes no no no 9/2/10 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 3 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Dimensional Data Legend AP = Alternate Service Panel BP = Blower Service Panel CP = Control Access Panel CMP = Compressor Service Panel A N R Q STANDARD FILTER RAIL FOR OPEN RETURN APPLICATIONS (ATTACHED BY HOOK METHOD) A S N AIR COIL Q BP PB Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz FIELD INSTALLED DUCT FLANGES AP AIR COIL SIDE AIR COIL SIDE M FRONT TOP VIEW - RIGHT RETURN M FRONT TOP VIEW - LEFT RETURN F G 4 3 1.00 1.00 F 4 G 3 2' (61 cm) Service Access ISOMETRIC VIEW - LEFT RETURN U T W AIR COIL SIDE AIR COIL SIDE AIR COIL AP AP V C H E 1.6in (4.1 cm) CONDENSATE 3/4 in PVC GLUE SOCKET 5 1.6 in (4.1 cm) 6 2 8 1 POWER SUPPLY 3/4" KNOCKOUT LOW VOLTAGE 1/2" KNOCKOUT LJ LK 1.6 in (4.1 cm) CONDENSATE 1.6 in 5 (4.1 cm) 8 2 7 CMP 1 C H E 6 8 JL AP 8 7 L K D FRONT VIEW - RIGHT RETURN D FRONT VIEW - LEFT RETURN 1.0 in (2.5 cm) 1.0 in RIGHT VIEW - RIGHT RETURN (2.5 cm) LEFT VIEW - LEFT RETURN WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 4 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Dimensional Data cont. Overall Cabinet 1 Vertical Models A B C D Width Depth Height** In in. 21.5 21.5 36.2 2.6 018-031 cm. 54.6 54.6 91.9 6.6 in. 21.5 21.5 40.2 2.6 041 cm. 54.6 54.6 102.1 6.6 Water Connections Electrical Knockouts 2 3 4 5 6 7 8 E F G H Loop Knockout J K L Out HWG In HWG Out Cond- Water HWG 1/2 in. ensate FPT Provisions cond 1/2 in. cond 1 in. cond 7.6 3.1 6.1 10.8 3/4" 0.875 9.4 5.4 7.4 19.3 7.9 15.5 27.4 19.1 mm 22.2 mm 23.9 13.7 18.8 7.6 3.1 6.1 10.8 3/4" 0.875 9.4 5.4 7.4 19.3 7.9 15.5 27.4 19.1 mm 22.2 mm 23.9 13.7 18.8 Discharge Connection Return Connection* Vertical Models M duct flange installed (±0.10 in) N P Q R S Filter Rack Supply Supply using deluxe filter rack (±0.10 in) T U V W Return Return Width Width Depth Depth Height in. 1.2 14.0 14.0 3.8 3.5 6.7 0.6 20.2 24.0 0.6 018-031 cm. 3.0 35.6 35.6 9.7 8.9 17.0 1.5 51.3 61.0 1.5 041 in. cm. 1.2 3.0 14.0 35.6 14.0 35.6 3.8 9.7 3.5 8.9 6.7 17.0 0.6 20.2 28.0 0.6 1.5 51.3 71.1 1.5 Condensate is 3/4 in. PVC female glue socket and is switchable from side to front. 9/2/10 *Dimensions for return connections are for a standard rail design with open return application only. The open filter rail, used in non-ducted returns, extends 1.2 in. [3.11 cm] from the unit. **Discharge flange is field installed and extends 1 in. (25.4 mm) from top of cabinet. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 5 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Physical Data Model Compressor (1 each) Factory Charge R-410A, oz [kg] Blower Motor & Blower Blower Motor Type/Speeds PSC Blower Motor- hp [W] PSC Blower Wheel Size (Dia x W), in [mm] PSC Coax and Water Piping Water Connection Size - FPT - in [mm] HWG Connection Size - FPT - in [mm] Coax & Piping Water Volume - gal [l] Vertical Air Coil Dimensions (H x W), in. [mm] Air Coil Total Face Area, ft2 [m2] Air Coil Tube Size, in [mm] Air Coil Number of rows Filter Standard - 1 in [25mm] MERV 4 Throwaway, in [mm] Shipping Weight- lb [kg] 018 Rotary 52 [1.47] 1/6 [134] 9 x 7 [229 x 178] 3/4 [19.1] 1/2 [12.7] 0.4 [1.49] 22 x 16 [559 x 406] 2.4 [0.220] 3/8 [9.5] 3 24 x 20 [610 x 508] 170 [77] Single Speed 023 031 Scroll 44 [1.25] 50 [1.42] 3 speeds 1/5 [149] 1/3 [249] 9 x 7 [229 x 178] 9 x 7 [229 x 178] 3/4 [19.1] 1/2 [12.7] 0.4 [1.49] 3/4 [19.1] 1/2 [12.7] 0.75 [2.83] 22 x 16 [559 x 406] 2.4 [0.220] 3/8 [9.5] 3 24 x 20 [610 x 508] 220 [100] 22 x 16 [559 x 406] 2.4 [0.220] 3/8 [9.5] 3 24 x 20 [610 x 508] 240 [109] 041 68 [1.93] 1/3 [249] 9 x 7 [229 x 178] 3/4 [19.1] 1/2 [12.7] 0.9 [3.41] 26 x 16 [660 x 406] 2.9 [0.269] 3/8 [9.5] 3 28 x 24 [711 x 610] 275 [125] 9/2/10 Electrical Data PSC Motor Model Rated Voltage 208-230/60/1 018 265/60/1 208-230/60/1 023 265/60/1 208-230/60/1 031 265/60/1 041 208-230/60/1 HACR circuit breaker in USA only Voltage Min/Max 187/253 238/292 187/253 238/292 187/253 238/292 187/253 MCC 10.4 8.7 21.0 14.0 22.0 17.5 31.0 Compressor RLA 6.7 5.6 13.5 9.0 14.1 11.2 20.0 LRA 33.5 28.0 58.3 54.0 73.0 60.0 115.0 Blower Motor FLA 1.1 1.0 1.2 1.1 1.5 1.5 3.5 Total Unit FLA 7.8 6.6 14.7 10.1 15.6 12.7 23.5 Min Circ Amp 9.5 8.0 18.1 12.4 19.1 15.5 28.5 Max Fuse/ HACR 15 10 30 20 30 25 45 9/2/10 Blower Performance Data Standard PSC Motor Model Blower Blower Spd Size Motor HP 0 0.05 0.10 0.15 Airflow (cfm) at External Static Pressure (in. wg) 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.60 0.70 0.80 0.90 1.00 H 875 860 845 830 820 805 790 770 750 725 700 - - - - - 018 M 9 x 7 1/6 760 750 740 730 720 710 700 680 660 640 620 - - - - - L 630 620 610 600 590 580 570 560 550 520 490 - - - - - H 995 975 950 925 895 865 835 795 750 715 680 595 - - - - 023 M 9 x 7 1/5 860 840 820 805 785 755 725 690 655 620 580 - - - - - L 790 775 760 745 725 690 655 635 610 575 535 - - - - - H 1160 1135 1110 1085 1055 1025 995 965 930 890 850 765 650 - - - 031 M 9 x 7 1/3 1035 1015 1000 975 955 930 905 875 845 810 780 685 - - - - L 855 845 840 830 820 800 785 760 740 710 685 610 - - - - H 1200 1170 1145 1115 1080 1035 995 955 915 875 835 765 640 - - - 041 M 9 x 7 1/2 1110 1085 1065 1035 1010 975 940 900 860 825 795 715 585 - - - L 1040 1020 1000 975 950 920 890 860 830 795 765 683 560 - - - Factory settings are in Bold 9/2/10 Air flow values are with dry coil and standard filter For wet coil performance first calculate the face velocity of the air coil (Face Velocity [fpm] = Airflow [cfm] / Face Area [sq ft]). Then for velocities of 200 fpm reduce the static capability by 0.03 in. wg, 300 fpm by 0.08 in. wg, 400 fpm by 0.12in. wg. and 500 fpm by 0.16 in. wg. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 6 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Operating Limits Operating Limits Air Limits Min. Ambient Air Rated Ambient Air Max. Ambient Air Min. Entering Air Rated Entering Air db/wb Max. Entering Air db/wb Water Limits Min. Entering Water Normal Entering Water Max. Entering Water Cooling (°F) (°C) 45 80 100 50 80.6/66.2 110/83 7.2 26.7 37.8 10.0 27/19 43/28.3 30 50-110 120 -1.1 10-43.3 48.9 Heating (°F) (°C) 45 7.2 70 21.1 85 29.4 40 4.4 68 20.0 80 26.7 20 30-70 90 -6.7 -1.1 32.2 NOTE: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. The operating limits are dependant upon three primary factors: 1) water temperature, 2) return air temperature, and 3) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation. Definitions ABBREVIATIONS AND DEFINITIONS: CFM = airflow, cubic feet/minute EWT = entering water temperature, Fahrenheit GPM = water flow in gallons/minute WPD = water pressure drop, PSI and feet of water EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) HC = air heating capacity, MBTUH TC = total cooling capacity, MBTUH SC = sensible cooling capacity, MBTUH KW = total power unit input, kilowatts HR = total heat of rejection, MBTUH HE = total heat of extraction, MBTUH HWC = hot water generator capacity, MBTUH EER = Energy Efficient Ratio = BTU output/Watt input COP = Coefficient of Performance = BTU output/BTU input LWT = leaving water temperature, °F LAT = leaving air temperature, °F TH = total heating capacity, MBTUH LC = latent cooling capacity, MBTUH S/T = sensible to total cooling ratio WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 7 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Correction Factor Tables Cooling Capacity Corrections Entering Air WB ºF 55 60 65 66.2 67 70 75 Total Clg Cap 0.898 0.912 0.967 0.983 1.000 1.053 1.168 60 0.723 65 0.866 0.632 Sensible Cooling Capacity Multipliers - Entering DB ºF 70 75 80 80.6 85 90 1.048 1.185 * * * * 0.880 1.078 1.244 1.260 * * 0.694 0.881 1.079 1.085 1.270 * 0.655 0.842 1.040 1.060 1.232 * 0.616 0.806 1.000 1.023 1.193 1.330 0.693 0.879 0.900 1.075 1.250 0.687 0.715 0.875 1.040 NOTE: * Sensible capacity equals total capacity at conditions shown. 95 * * * * * 1.404 1.261 100 * * * * * * 1.476 Power Input 0.985 0.994 0.997 0.999 1.000 1.003 1.007 Heat of Rejection 0.913 0.927 0.972 0.986 1.000 1.044 1.141 11/10/09 Heating Corrections Ent Air DB °F 45 50 55 60 65 68 70 75 80 Htg Cap 1.062 1.050 1.037 1.025 1.012 1.005 1.000 0.987 0.975 Power 0.739 0.790 0.842 0.893 0.945 0.976 1.000 1.048 1.099 Heat of Ext 1.158 1.130 1.096 1.064 1.030 1.012 1.000 0.970 0.930 11/10/09 Air Flow Corrections Airflow CFM Per Ton of Clg % of Nominal 240 60 275 69 300 75 325 81 350 88 375 94 400 100 425 106 450 113 475 119 500 125 520 130 Total Cap 0.922 0.944 0.959 0.971 0.982 0.992 1.000 1.007 1.012 1.017 1.019 1.020 Cooling Sens Cap Power 0.786 0.827 0.860 0.894 0.929 0.965 1.000 1.034 1.065 1.093 1.117 1.132 0.910 0.924 0.937 0.950 0.964 0.982 1.000 1.020 1.042 1.066 1.092 1.113 Heat of Rej 0.920 0.940 0.955 0.967 0.978 0.990 1.000 1.010 1.018 1.026 1.033 1.038 Htg Cap 0.943 0.958 0.968 0.977 0.985 0.993 1.000 1.007 1.013 1.018 1.023 1.026 Heating Power 1.150 1.105 1.078 1.053 1.031 1.014 1.000 0.990 0.983 0.980 0.978 0.975 Heat of Ext 0.893 0.922 0.942 0.959 0.973 0.988 1.000 1.011 1.020 1.028 1.034 1.038 11/10/09 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 8 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Antifreeze Corrections Catalog performance can be corrected for antifreeze use. Please use the following table and note the example given. Antifreeze Type Antifreeze % by wt Cooling Capacity Heating Capacity Pressure Drop EWT - degF [DegC] 90 [32.2] 30 [-1.1] 30 [-1.1] Water 0 1.000 1.000 1.000 Ethylene Glycol Propylene Glycol Ethanol Methanol 10 0.991 20 0.979 30 0.965 40 0.955 50 0.943 10 0.981 20 0.969 30 0.950 40 0.937 50 0.922 10 0.991 20 0.972 30 0.947 40 0.930 50 0.911 10 0.986 20 0.970 30 0.951 40 0.936 50 0.920 0.973 0.943 0.917 0.890 0.865 0.958 0.913 0.854 0.813 0.770 0.927 0.887 0.856 0.815 0.779 0.957 0.924 0.895 0.863 0.833 1.075 1.163 1.225 1.324 1.419 1.130 1.270 1.433 1.614 1.816 1.242 1.343 1.383 1.523 1.639 1.127 1.197 1.235 1.323 1.399 Warning: Gray area represents antifreeze concentrations greater than 35% by weight and should be avoided due to the extreme performance penalty they represent. Antifreeze Correction Example Antifreeze solution is Propylene Glycol 20% by weight. Determine the corrected heating and cooling performance at 30°F and 90°F respectively as well as pressure drop at 30°F for a Versatec Ultra Series UCV023 PSC. The corrected cooling capacity at 90°F would be: 23,500 MBtuh x 0.969 = 22,772 MBtuh The corrected heating capacity at 30°F would be: 16,000 MBtuh x 0.913 = 14,608 MBtuh The corrected pressure drop at 30°F and 6 GPM would be: 10.5 feet of head x 1.270 = 13.34 feet of head WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 9 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Pressure Drop Model 018 023 031 041 GPM 3.0 4.0 5.0 6.0 3.0 4.5 6.0 8.0 4.0 6.0 8.0 10.0 5.0 8.0 11.0 14.0 30°F 1.1 1.9 3.3 4.5 1.1 2.4 4.5 6.7 0.9 1.9 3.7 4.8 1.5 3.4 7.9 9.1 Pressure Drop (psi) 50°F 70°F 90°F 1.0 0.8 0.7 1.8 1.6 1.5 3.2 3.0 2.9 4.4 4.3 4.1 1.0 0.9 0.8 2.2 2.1 2.0 4.4 4.3 4.1 6.6 6.5 6.3 0.8 0.7 0.6 1.8 1.7 1.6 3.6 3.5 3.4 4.7 4.6 4.5 1.2 0.9 0.5 3.1 2.8 2.5 7.5 7.2 6.9 8.8 8.5 8.2 110°F 0.5 1.3 2.7 4.0 0.6 1.9 4.0 6.2 0.5 1.5 3.3 4.4 0.4 2.1 6.6 7.9 9/2/10 Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 10 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz UCV018 - Performance Data Single Speed PSC (600 CFM) EWT Flow °F gpm 3.0 20 4.0 5.0 3.0 30 4.0 5.0 3.0 40 4.0 5.0 3.0 50 4.0 5.0 3.0 60 4.0 5.0 3.0 70 4.0 5.0 3.0 80 4.0 5.0 3.0 90 4.0 5.0 3.0 100 4.0 5.0 3.0 110 4.0 5.0 3.0 120 4.0 5.0 WPD PSI FT 1.2 2.8 2.0 4.6 3.4 7.8 1.1 2.6 1.9 4.4 3.3 7.6 1.1 2.5 1.8 4.3 3.2 7.5 1.0 2.3 1.8 4.1 3.2 7.3 0.9 2.1 1.7 3.9 3.1 7.1 0.8 1.9 1.6 3.7 3.0 6.9 0.8 1.8 1.5 3.6 2.9 6.8 0.7 1.6 1.5 3.4 2.9 6.6 0.6 1.4 1.4 3.2 2.8 6.4 0.5 1.2 1.3 3.0 2.7 6.2 0.5 1.1 1.2 2.9 2.6 6.1 HEATING - EAT 70°F HC Power HE LAT kBtuh kW kBtuh °F COP Operation not recommended 13.0 14.5 14.9 15.7 16.5 16.0 17.0 18.0 17.5 18.5 19.5 19.0 20.0 21.0 21.9 22.6 23.3 24.7 25.1 25.5 1.21 8.9 88.1 3.15 Operation not recommended 1.29 10.1 90.3 3.29 1.31 10.4 91.0 3.33 Operation not recommended 1.34 11.1 92.2 3.43 1.37 11.8 93.4 3.52 1.36 11.4 92.7 3.45 1.40 12.2 94.2 3.57 1.43 13.1 95.8 3.69 1.43 12.6 95.0 3.60 1.45 13.5 96.5 3.73 1.48 14.5 98.1 3.86 1.49 13.9 97.3 3.74 1.51 14.8 98.9 3.88 1.53 15.8 100.4 4.02 1.56 16.5 101.7 4.10 1.58 17.2 102.8 4.17 1.61 17.8 103.9 4.25 1.64 19.1 106.2 4.43 1.66 19.5 106.8 4.44 1.68 19.8 107.4 4.45 Operation not recommended HWC kBtuh TC kBtuh COOLING - EAT 80/67°F SC S/T Power HR kBtuh Ratio kW kBtuh EER Operation not recommended 1.4 Operation not recommended 1.5 18.2 11.8 0.65 0.86 21.1 21.0 1.5 18.4 12.0 0.65 0.81 21.2 22.7 Operation not recommended 1.6 19.1 12.4 0.65 0.92 22.2 20.8 1.6 19.4 12.6 0.65 0.89 22.4 21.9 1.7 19.7 12.8 0.65 0.98 23.0 20.1 1.7 20.0 13.0 0.65 0.97 23.3 20.6 1.8 20.3 13.1 0.65 0.96 23.6 21.1 1.9 18.7 12.4 0.66 1.07 22.3 17.6 1.9 18.9 12.6 0.67 1.06 22.5 17.9 2.0 19.2 12.8 0.67 1.05 22.7 18.3 2.1 17.7 12.0 0.68 1.15 21.6 15.4 2.1 17.9 12.3 0.69 1.14 21.7 15.7 2.2 18.0 12.5 0.69 1.13 21.9 15.9 2.4 16.6 11.4 0.69 1.36 21.2 12.2 2.4 16.8 11.7 0.70 1.30 21.2 12.9 2.5 17.0 12.0 0.70 1.26 21.3 13.5 2.8 15.4 10.8 0.70 1.49 20.5 10.3 2.8 15.7 11.1 0.71 1.43 20.5 11.0 2.8 16.0 11.4 0.71 1.38 20.7 11.6 Operation not recommended 14.9 11.0 0.74 1.52 20.1 9.8 15.1 11.1 0.73 1.47 20.1 10.3 Operation not recommended 13.9 10.5 0.76 1.60 19.4 8.7 14.2 10.7 0.75 1.56 19.5 9.1 Operation not recommended 13.2 10.1 0.76 1.76 19.2 7.5 13.5 10.2 0.76 1.71 19.3 7.9 HWC kBtuh ----- ----0.9 0.9 0.9 1.1 1.1 1.0 1.3 1.3 1.2 1.7 1.6 1.5 2.2 2.0 1.9 2.5 2.3 3.2 3.0 4.0 3.6 9/2/10 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 11 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz UCV023 - Performance Data Single Speed PSC (700 CFM) EWT °F 20 30 40 50 60 70 80 90 100 110 120 Flow gpm 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 3.0 4.5 6.0 WPD PSI FT 1.2 2.8 2.4 5.6 4.6 10.6 1.1 2.6 2.4 5.5 4.5 10.5 1.1 2.5 2.3 5.3 4.5 10.3 1.0 2.3 2.2 5.2 4.4 10.2 1.0 2.2 2.2 5.0 4.3 10.0 0.9 2.0 2.1 4.9 4.3 9.9 0.8 1.9 2.1 4.7 4.2 9.7 0.8 1.7 2.0 4.6 4.1 9.6 0.7 1.6 1.9 4.4 4.1 9.4 0.6 1.4 1.9 4.3 4.0 9.3 0.6 1.3 1.8 4.1 3.9 9.1 HC kBtuh HEATING - EAT 70°F Power HE LAT kW kBtuh °F COP Operation not recommended 15.0 17.9 18.2 19.6 20.3 20.8 21.6 22.3 23.0 23.8 24.6 25.2 26.0 26.9 27.9 28.5 29.2 30.6 31.0 31.5 1.68 9.2 85.3 Operation not recommended 1.74 11.9 88.7 1.76 12.2 89.1 Operation not recommended 1.78 13.6 90.7 1.80 14.1 91.4 1.79 14.7 92.1 1.82 15.4 92.9 1.84 16.0 93.8 1.83 16.7 94.6 1.85 17.5 95.5 1.88 18.2 96.4 1.87 18.8 97.1 1.89 19.6 98.1 1.91 20.4 99.1 1.88 21.5 100.2 1.90 22.0 101.0 1.92 22.6 101.8 1.88 24.1 103.4 1.91 24.5 103.9 1.93 24.9 104.5 2.61 3.01 3.04 3.24 3.30 3.41 3.48 3.55 3.68 3.76 3.84 3.94 4.03 4.12 4.35 4.40 4.46 4.76 4.77 4.78 Operation not recommended TC kBtuh COOLING - EAT 80/67°F SC kBtuh S/T Ratio Power HR kW kBtuh EER Operation not recommended 26.3 26.7 26.5 26.8 26.4 26.6 26.9 25.7 25.9 26.2 25.0 25.3 25.5 23.8 24.1 24.5 22.7 23.0 23.5 21.7 22.1 20.2 20.6 18.4 18.8 Operation not recommended 16.7 0.63 1.11 30.1 17.0 0.64 1.04 30.2 Operation not recommended 17.0 0.64 1.20 30.6 17.3 0.64 1.14 30.7 17.3 0.66 1.37 31.1 17.4 0.65 1.30 31.1 17.5 0.65 1.23 31.1 17.0 0.66 1.52 30.9 17.1 0.66 1.44 30.9 17.2 0.66 1.36 30.8 16.7 0.67 1.67 30.7 16.8 0.67 1.58 30.6 16.9 0.66 1.49 30.6 16.1 0.68 1.81 30.0 16.3 0.68 1.73 30.0 16.5 0.67 1.68 30.2 15.6 0.69 2.01 29.6 15.8 0.69 1.92 29.6 16.0 0.68 1.86 29.8 Operation not recommended 15.1 0.69 2.20 29.2 15.2 0.69 2.13 29.3 Operation not recommended 14.2 0.70 2.46 28.6 14.4 0.70 2.39 28.8 Operation not recommended 14.2 0.77 2.85 28.2 14.4 0.77 2.77 28.3 23.8 25.7 22.0 23.6 19.3 20.5 21.9 16.9 18.0 19.3 15.0 16.0 17.1 13.1 13.9 14.6 11.3 12.0 12.6 9.9 10.4 8.2 8.6 6.5 6.8 9/2/10 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 12 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz UCV031 - Performance Data Single Speed PSC (1000 CFM) EWT Flow °F gpm 4.0 20 6.0 8.0 4.0 30 6.0 8.0 4.0 40 6.0 8.0 4.0 50 6.0 8.0 4.0 60 6.0 8.0 4.0 70 6.0 8.0 4.0 80 6.0 8.0 4.0 90 6.0 8.0 4.0 100 6.0 8.0 4.0 110 6.0 8.0 4.0 120 6.0 8.0 WPD PSI FT 1.0 2.2 1.9 4.5 3.8 8.7 0.9 2.1 1.9 4.4 3.7 8.5 0.9 2.0 1.8 4.3 3.7 8.4 0.8 1.9 1.8 4.1 3.6 8.3 0.8 1.8 1.7 4.0 3.6 8.2 0.7 1.6 1.7 3.9 3.5 8.1 0.7 1.5 1.6 3.8 3.5 8.0 0.6 1.4 1.6 3.7 3.4 7.9 0.6 1.3 1.6 3.6 3.4 7.8 0.5 1.2 1.5 3.5 3.3 7.6 0.5 1.1 1.5 3.3 3.3 7.5 HEATING - EAT 70°F HC Power HE LAT kBtuh kW kBtuh °F COP HWC kBtuh TC kBtuh COOLING - EAT 80/67°F SC S/T Power HR kBtuh Ratio kW kBtuh EER HWC kBtuh Operation not recommended Operation not recommended 20.7 2.10 13.5 87.2 2.89 1.9 Operation not recommended Operation not recommended 24.6 2.10 17.4 90.8 3.43 2.1 30.4 20.8 0.68 1.24 34.6 24.6 --- 24.0 2.12 16.8 90.2 3.32 2.1 30.8 21.2 0.69 1.16 34.8 26.6 --- Operation not recommended Operation not recommended 27.2 2.17 19.8 93.2 3.68 2.3 32.0 22.5 0.70 1.35 36.6 23.7 --- 27.6 2.19 20.1 93.5 3.69 2.4 32.5 23.1 0.71 1.28 36.8 25.4 --- 29.0 2.21 21.5 94.9 3.85 2.5 33.1 23.5 0.71 1.54 38.4 21.5 1.4 30.1 2.24 22.4 95.8 3.94 2.6 33.6 24.3 0.72 1.47 38.6 22.9 1.3 31.1 2.26 23.4 96.8 4.03 2.7 34.1 25.0 0.73 1.40 38.9 24.4 1.3 32.3 2.28 24.5 97.9 4.15 2.9 31.9 23.1 0.72 1.70 37.7 18.8 1.6 33.4 2.31 25.6 98.9 4.25 2.9 32.5 23.5 0.72 1.63 38.0 19.9 1.5 34.6 2.34 26.6 100.0 4.34 3.0 33.1 24.0 0.72 1.56 38.4 21.2 1.4 35.6 2.35 27.6 101.0 4.44 3.2 30.7 22.6 0.74 1.86 37.0 16.5 2.0 36.8 2.38 28.7 102.1 4.53 3.3 31.4 22.8 0.73 1.79 37.5 17.5 1.9 38.0 2.41 29.8 103.2 4.62 3.4 32.0 22.9 0.72 1.72 37.9 18.6 1.8 39.3 2.46 30.9 104.4 4.68 3.6 28.8 20.8 0.72 2.07 35.9 13.9 2.5 40.2 2.49 31.7 105.2 4.73 3.7 29.6 21.4 0.72 1.97 36.3 15.0 2.4 41.2 2.53 32.5 106.1 4.78 3.8 30.2 22.3 0.74 1.91 36.7 15.8 2.3 43.0 2.57 34.2 107.8 4.89 4.1 27.0 19.0 0.70 2.27 34.7 11.9 3.3 43.6 2.61 34.7 108.4 4.90 4.2 27.8 20.0 0.72 2.17 35.2 12.8 3.1 44.3 2.64 35.3 109.0 4.92 4.3 28.4 21.6 0.76 2.10 35.6 13.5 3.0 Operation not recommended 26.3 20.7 0.78 2.43 34.7 10.8 3.9 26.8 20.9 0.78 2.36 34.8 11.4 3.7 Operation not recommended Operation not recommended 24.6 19.8 0.81 2.68 33.8 9.2 4.9 25.1 20.1 0.80 2.61 34.0 9.6 4.5 Operation not recommended 22.5 19.1 0.85 3.03 32.8 7.4 5.7 23.0 19.4 0.84 2.94 33.0 7.8 5.4 9/2/10 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 13 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz UCV041 - Performance Data Single Speed PSC (1200 CFM) EWT Flow °F gpm 5.0 20 8.0 11.0 5.0 30 8.0 11.0 5.0 40 8.0 11.0 5.0 50 8.0 11.0 5.0 60 8.0 11.0 5.0 70 8.0 11.0 5.0 80 8.0 11.0 5.0 90 8.0 11.0 5.0 100 8.0 11.0 5.0 110 8.0 11.0 5.0 120 8.0 11.0 WPD PSI FT 1.6 3.8 3.6 8.2 8.0 18.5 1.5 3.4 3.4 7.8 7.9 18.1 1.3 3.0 3.2 7.5 7.7 17.8 1.2 2.7 3.1 7.1 7.5 17.4 1.0 2.3 2.9 6.7 7.4 17.0 0.9 2.0 2.8 6.4 7.2 16.7 0.7 1.6 2.6 6.0 7.1 16.3 0.5 1.2 2.5 5.7 6.9 16.0 0.4 0.9 2.3 5.3 6.8 15.6 0.4 0.9 2.1 4.9 6.6 15.2 0.4 0.9 2.0 4.6 6.5 14.9 HEATING - EAT 70°F HC Power HE LAT kBtuh kW kBtuh °F COP Operation not recommended 26.3 31.9 32.0 35.3 36.2 37.5 39.0 40.4 41.6 43.3 45.0 45.7 47.7 49.6 51.5 52.9 54.3 57.2 58.1 59.0 2.40 18.1 88.3 3.21 Operation not recommended 2.86 22.1 92.6 3.27 2.90 22.1 92.7 3.23 Operation not recommended 2.96 25.2 95.2 3.50 3.00 26.0 95.9 3.54 3.00 27.3 96.9 3.66 3.05 28.5 98.1 3.74 3.10 29.8 99.2 3.82 3.10 31.0 100.1 3.93 3.15 32.6 101.4 4.03 3.20 34.1 102.7 4.12 3.20 34.8 103.3 4.19 3.25 36.6 104.8 4.30 3.30 38.3 106.3 4.41 3.31 40.2 107.7 4.56 3.35 41.4 108.8 4.62 3.40 42.7 109.9 4.68 3.41 45.6 112.2 4.92 3.46 46.3 112.8 4.93 3.50 47.1 113.5 4.94 Operation not recommended HWC kBtuh TC kBtuh COOLING - EAT 80/67°F SC S/T Power HR kBtuh Ratio kW kBtuh EER HWC kBtuh Operation not recommended 1.9 Operation not recommended 2.1 43.3 25.6 0.59 1.81 49.5 23.9 --- 2.1 43.9 26.1 0.59 1.70 49.7 25.8 --- Operation not recommended 2.3 44.7 27.7 0.62 1.96 51.4 22.9 --- 2.4 45.3 27.9 0.62 1.85 51.6 24.5 --- 2.5 45.7 30.0 0.66 2.20 53.2 20.8 1.4 2.6 46.2 29.8 0.65 2.10 53.3 22.0 1.3 2.7 46.6 29.6 0.64 2.00 53.4 23.3 1.3 2.9 44.3 29.1 0.66 2.45 52.7 18.1 1.6 2.9 44.6 29.1 0.65 2.33 52.5 19.2 1.5 3.0 44.9 29.1 0.65 2.20 52.4 20.4 1.4 3.2 42.9 28.1 0.66 2.70 52.1 15.9 2.0 3.3 43.1 28.3 0.66 2.55 51.8 16.9 1.9 3.4 43.2 28.5 0.66 2.40 51.4 18.0 1.8 3.6 40.1 26.5 0.66 2.92 50.1 13.7 2.5 3.7 40.8 24.2 0.59 2.79 50.3 14.6 2.4 3.8 41.3 26.8 0.65 2.70 50.5 15.3 2.3 4.1 37.3 24.9 0.67 3.25 48.4 11.5 3.3 4.2 38.5 20.0 0.52 3.10 49.1 12.4 3.1 4.3 39.3 25.1 0.64 3.00 49.5 13.1 3.0 Operation not recommended 36.8 24.1 0.66 3.46 48.6 10.6 3.9 37.4 24.4 0.65 3.35 48.8 11.2 3.7 Operation not recommended 34.8 23.3 0.67 3.80 47.8 9.1 4.9 35.5 23.6 0.66 3.70 48.1 9.6 4.5 Operation not recommended 32.4 22.3 0.69 4.22 46.8 7.7 5.7 33.1 22.6 0.68 4.10 47.1 8.1 5.4 9/2/10 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 14 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Wiring Schematic Versatec Microprocessor 208-230/60/1 PSC PSC Blower Motor Grn Brn Wht Cap 3 Airflow Settings HM L White Compressor S Blue Cap Tan C R Red Black T2 T1 CC L2 L1 Note 2 Green (93) Ground Neutral Disconnect Black (95) L1 L1 Black RB 3 1 Black Red (97) L2 L2 L3 L3 Unit Power Supply 208-230-265/60/1 G P3 P3 P1 R C Y O G/Y2 LO ES NS LS Note 2 Red 208V Blue 230V Black 265V Transformer RB Violet Black/White Yellow Legend Factory Low Voltage Wiring Factory Line Voltage Wiring T Field Low Voltage Wiring Field Line Voltage Wiring Optional Block DC Voltage PCB Traces Field Zone Sensor Wiring Internal Junction Quick Connect Terminal L1 Field Wiring Lug Ground Relay Contacts N.O., N.C. CC Compressor Contactor CO Condensate Overflow Sensor ES Emergency Shutdown HP High Pressure Switch LP Low Pressure Switch FD Freeze Detection Sensor RB Blower Relay RV Reversing Valve Coil 1 2 3 Thermistor Relay Coil Switch - Condensate Overflow Switch - High pressure Switch - Low pressure Polarized connector Capacitor LED Display Mode Table Status Display Mode LED SW1-4 On , SW2 Off Drain Drain Pan Overflow Lockout Water Flow Freeze Detection Lockout(Loop <= 15°F, Well <= 30°F) High Press. High Pressure Lockout Low Press. Low Pressure Lockout Air Flow Not Used Status Microprocessor Malfunction* DHW Limit Not Used DHW SW2 Status(Off =Down Position, On=Up Position) Diagnostic Display Modes Current Fault Display Mode Inputs Display Mode LED SW1-4 On, SW2 On SW1-4 Off, SW2 Off Drain Drain Pan Overflow Lockout Y Water Flow Freeze Detection Lockout G High Press. High Pressure Lockout O Low Press. Low Pressure Lockout ES Air Flow Not Used NS Status Not Used LS DHW Limit Not Used Not Used HWD SW2 = On SW2 = Off * Flashing Status Light Indicates the Board is Functioning Prope.rly A Solid "On" Indicates a Board Malfunctio. n Outputs Display Mode SW1-4 Off, SW2 On Compressor Blower Reversing Valve ES NS LS Not Used SW2 = On Black/White CC Violet Violet Green (000) Fan Fan COM CC CCG C C R R SW1 On Test Loop Comm. T-Stat Inputs/Outputs Split Mode Normal Well Normal Status Normal P2 1-HP 6-HP 2-LP 7-LP 3 8-CO 4-RV 9-RV 5-FP 10-FP HP Black Black LP Blue Blue CO Brown Orange RV Orange Yellow T FD Yellow Black Black Black Drain R Water Flow R High Press. R Low Press. R Air Flow R Status G DHW Limit Y HWD R OFF SW2 ON Mode Htg Clg Blower Only Operational Logic Table Single-Speed Inputs Blower Comp Y Auto ON Y,O Auto ON G ON OFF Notes: 1 Optional, factory installed unit mounted disconnect. 2 Swap blue and red leads for 208V operation Control Timing Table Event Normal Mode Test Mode Power On Delay 5 minutes 15 seconds Compressor On Delay 10 seconds 2 seconds Compressor Minimum On Time 2 minutes 5 seconds Compressor Short Cycle Delay 5 minutes 15 seconds Blower Off Delay 30 seconds 5 seconds Fault Recognition Delay High Pressure Less than 1 second Less than 1 second Start-Up Bypass Low Pressure 2 minutes 0 seconds RV Fault Recognition Delay Low Pressure 30 seconds 30 seconds OFF Start-Up Bypass Freeze Detection 2 minutes 0 seconds ON Fault Recognition Delay Freeze Detection 30 seconds 30 seconds OFF Fault Recognition Delay Condensate Overflow 30 seconds 30 seconds Factory Setup DIP Switches(SW1) DIP Switch Number Description SW1- 1 Service Test Mode On the contro,l allows field selection of"NORMAL" or "TEST" operational modes, Test mode accelerates most timing function1s6 times to allow faster troubleshootin.gTest mode also allows viewing the"CURRENT" status of the fault inputs on the LED display. "OFF" Position "ON" Position Test Mode Normal Speed Operation SW1- 2 SW1- 3 SW1- 4 Freeze Detection Setting This DIP switch allows field selection of low source water thermistor fault sensing for "WELL" water (30°F) or "LOOP" (15°F)for anti-freeze protected earth loop.s Not Available I/O Display Mode This DIP switch enables Input/Output Display or Status/Current Fault on LED Boar.d Refer to SW2 for operation and positioning. "LOOP" (15°F) N/A "WELL" (30°F) Normal Operation Input/Output Status/Current Display Mode Fault Display Mode SW1- 5 SW2 Not Available N/A Normal Operation Page 1 LED Display(On LED Board) This DIP switch enables Normal Status or Input display mode in the "OFF" position and Status or Inputs Current Fault or Output display mode in the "ON" position. Display Mode Current Fault or Output Display Mode 97P800-02 09/02/10 WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 15 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Engineering Guide Specifications General Furnish and install WaterFurnace Water Source Heat Pumps, as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in the schedule and the specifications that follow. The reverse cycle heating/ cooling units shall be vertical upflow air discharge. Units shall be AHRI/ISO 13256-1 certified and listed by a nationally recognized safety-testing laboratory or agency, such as ETL Testing Laboratory. Each unit shall be computer runtested at the factory with conditioned water and operation verified to catalog data. Each unit shall be mounted on a pallet and shipped in a corrugated box or stretch-wrapped. The units shall be designed to operate with entering liquid temperature between 20°F and 120°F [-6.7°C and 48.9°C]. Casing and Cabinet The cabinet shall be fabricated from heavy-gauge galvanized steel and finished with optional corrosionresistant powder coating. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. The interior shall be insulated with 1/2 in. thick, multi-density, cleanable aluminum foil coated glass fiber with edges sealed or tucked under flanges to prevent the introduction of glass fibers into the discharge air. Standard cabinet panel insulation must meet NFPA 90A requirements, air erosion and mold growth limits of UL-181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements or unit(s) will not be accepted. One (horizontal) to two (vertical) blower and two compressor compartment access panels shall be `lift-out' removable with supply and return ductwork in place. A duct collar shall be provided on the supply air opening. Standard size 1 in. [2.54 cm] MERV 4 filters shall be provided with each unit. Units shall have a return air filter rack that is field convertible from 1 in. [2.54 cm] to 2 in. [5.1 cm]. The upflow vertical units shall have a removable insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise and to permit operational service testing without air bypass. Vertical units shall be supplied with left or right horizontal air inlet and top vertical air discharge. The compressor shall be mounted using selected durometer grommets to provide vibration free compressor mounting. Refrigerant Circuit All units shall utilize the non-ozone depleting and low global warming potential refrigerant R-410A. All units shall contain a sealed refrigerant circuit including a hermetic motorcompressor, bidirectional thermostatic expansion valve, finned tube air-to-refrigerant heat exchanger, reversing valve, coaxial tube water-to-refrigerant heat exchanger, optional hot water generator coil, and service ports. Compressors shall be high-efficiency single speed rotary or scroll type designed for heat pump duty and mounted on vibration isolators. Compressor motors shall be single-phase PSC with overload protection. The air coil shall be sized for low-face velocity and constructed of lanced aluminum fins bonded to rifled copper tubes in a staggered pattern not less than three rows deep for enhanced performance. Option: FormiShield electro-coated air coil for maximum protection against formicary corrosion. The coaxial water-to-refrigerant heat exchanger shall be designed for low water pressure drop and constructed of a convoluted copper (cupronickel option) inner tube and a steel outer tube. Refrigerant to air heat exchangers shall utilize enhanced corrugated lanced aluminum fins and rifled copper tube construction rated to withstand 600 PSIG (4135 kPa) refrigerant working pressure. Refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 600 PSIG (4135 kPa) working refrigerant pressure and 450 PSIG (3101 kPa) working water pressure. The thermostatic expansion valve shall provide proper superheat over the entire liquid temperature range with minimal "hunting." The valve shall operate bidirectionally without the use of check valves. Option: Cupronickel refrigerant to water heat exchanger shall be of copper-nickel inner water tube and steel refrigerant outer tube design, rated to withstand 600 PSIG (4135 kPa) working refrigerant pressure and 450 PSIG (3101 kPa) working water pressure. Water lines shall also be of cupronickel construction. Option: Hot water generator - Internal double wall vented hot water generator coil refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 600 PSIG (4135 kPa) working refrigerant pressure and 450 PSIG (3101 kPa) working water pressure. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 16 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz Engineering Guide Specifications cont. Option: ThermaShield coated water-to-refrigerant heat exchanger, water lines and refrigerant suction lines shall be insulated to prevent condensation at low liquid temperatures below 50°F. Blower motor and Assembly The blower shall be a direct drive centrifugal type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low outlet velocity operation. The blower housing shall be removable from the unit without disconnecting the supply air ductwork for servicing of the blower motor. The blower motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated and have thermostatic overload protection. Option: PSC blower motor shall be a three-speed PSC type. Electrical A control box shall be located within the unit compressor compartment and shall contain a 75VA transformer, 24 volt activated, 2 pole compressor contactor, terminal block for thermostat wiring and solid-state controller for complete unit operation. Electromechanical operation WILL NOT be accepted. Units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 volt and provide heating or cooling as required by the remote thermostat/sensor. A Versatec microprocessor-based controller that interfaces with a multi-stage electronic thermostat to monitor and control unit operation shall be provided. The control shall provide operational sequencing, blower speed control, high and low pressure switch monitoring, freeze detection, condensate overflow sensing, lockout mode control, LED status and fault indicators, fault memory, field selectable options and accessory output. The control shall provide fault retry three times before locking out to limit nuisance trips. A detachable terminal block with screw terminals will be provided for field control wiring. All units shall have knockouts for entrance of low and line voltage wiring. The blower motor and control box shall be harness plug wired for easy removal. Piping Supply and return water connections shall be FPT copper fittings fixed to the corner post, which eliminate the need for backup pipe wrenches. With vertical units, the condensate connection shall be a 3/4 in. [19.1 mm] PVC socket with internally-trapped hose that can be routed to front or side corner post locations. Accessories Thermostat (field-installed) A multi-stage auto-changeover electronic digital thermostat shall be provided. The thermostat shall offer two heating stages and one cooling stage with precise temperature control. An OFF-HEAT-AUTO-COOL-EMERG system switch, OFF-AUTO blower switch, and indicating LEDs shall be provided. The thermostat shall display in °F or °C. Hose Kits Ball Valves (field-installed) A flexible steel braid hose featuring Kevlar® reinforced EPDM core with ANSI 302/304 stainless steel outer braid and fire rated materials per ASTM E 84-00 (NFPA 255, ANSI/UL 723 & UBC 8-1). Ball valve at one end; swivel connector with adapter at the other end (swivel to adapter connection via fiber or EPDM gasket). Swivel connection provides union between heat pump and piping system. The hoses feature brass fittings, stainless steel ferrules. A full port ball valve shall be provided with integral P/T (pressure/temperature) port on supply hose. Specifications: · Temperature range of 35°F [2°C] to 180°F [82°C]. · Max. working pressure of 400 psi [2757 kPa] for 1/2 in. and 3/4 in. hose kits; max. working pressure of 350 psi [kPa] for 1 in. and 1-1/4 in. hose kits. Hose Kits Automatic Balancing and Ball Valves (field-installed) A flexible steel braid hose featuring Kevlar® reinforced EPDM core with ANSI 302/304 stainless steel outer braid and fire rated materials per ASTM E 84-00 (NFPA 255, ANSI/UL 723 & UBC 8-1). Ball valve at one end; swivel connector with adapter at the other end (swivel to adapter connection via fiber or EPDM gasket). Swivel connection provides union between heat pump and piping system. The hoses feature brass fittings, stainless steel ferrules. A full port ball valve shall be provided with integral P/T (pressure/temperature) port on supply hose and automatic balancing valve with integral P/T ports and full port ball valve on return hose. WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 17 Page _____ of _____ Contractor: Engineer: Project Name: P.O.: Unit Tag: Engineering Guide Specifications cont. Specifications: · Temperature range of 35°F [2°C] to 180°F [82°C] · Max. working pressure of 400 psi [2757 kPa] for 1/2 in. and 3/4 in. hose kits; max. working pressure of 350 psi [2413 kPa] for 1 in. and 1-1/4 in. hose kits · Minimum burst pressure of four times working pressure Hose Kits Automatic Balancing and Ball Valves with `Y' strainer (field-installed) A flexible steel braid hose featuring Kevlar® reinforced EPDM core with ANSI 302/304 stainless steel outer braid and fire rated materials per ASTM E 84-00 (NFPA 255, ANSI/UL 723 & UBC 8-1). Ball valve at one end; swivel connector with adapter at the other end (swivel to adapter connection via fiber or EPDM gasket). Swivel connection provides union between heat pump and piping system. The hoses feature brass fittings, stainless steel ferrules. A "y" strainer is provided on one end for fluid straining and integral "blowdown" valve. A full port ball valve shall be provided with integral P/T (pressure/temperature) port on supply hose and automatic balancing valve with integral P/T ports and full port ball valve on return hose. Specifications: · Temperature range of 35°F [2°C] to 180°F [82°C] · Max. working pressure of 400 psi [2756 kPa] for 1/2 in. and 3/4 in. hose kits; max. working pressure of 350 psi [2413 kPa] for 1 in. and 1-1/4 in. hose kits · Minimum burst pressure of four times working pressure Versatec Ultra Series UCV Commercial 1.5 - 3.5 Tons 60Hz WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser's approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace's opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com. SD1220AU 09/10 18 Page _____ of _____Adobe PDF Library 8.0 Adobe InDesign CS3 (5.0.4)