Sam Lin
CN22N92T 001 15B TI5000
Intelbras Industria de Telecomunicacao Eletronica Brasileira TI5000 TI5000 2A76R-TI5000 2A76RTI5000 ti5000
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 15 Pages, 981.37KB
Document DEVICE REPORTGetApplicationAttachment.html?id=6100615Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: Kunden-Referenz-Nr.: Client reference no.: Auftraggeber: Client: Prüfgegenstand: Test item: Bezeichnung / Typ-Nr.: Identification / Type no.: Auftrags-Inhalt: Order content: Prüfgrundlage: Test specification: CN22N92T 001 Auftrags-Nr.: Order no.: 168374470 N/A Auftragsdatum: 2022-05-26 Order date: Intelbras Industria de Telecomunicacao Eletronica Brasileira Rodovia BR 101 KM 210 Area Industrial Sao Jose Brazil Smart terminal TI5000 Test Report FCC CFR Title 47, Part 15, Subpart B Seite 1 von 15 Page 1 of 15 Wareneingangsdatum: 2022-06-27 Date of sample receipt: Prüfmuster-Nr.: Test sample no: A003285007-001 A003285010-001 A003285800-001~013 Prüfzeitraum: Testing period: 2022-07-26 2022-08-03 Please refer to Photo Document Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: Datum: Date: 2022-08-30 Stellung / Position: Sonstiges / Other: X Signed by: Bell Hu Project Manager FCC ID: 2A76R-TI5000 genehmigt von: authorized by: Ausstellungsdatum: Issue date: 2022-08-30 X Signed by: Lin Lin Stellung / Position: Reviewer Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: * Legend: 1 = sehr gut 2 = gut P(ass) = entspricht o.g. Prüfgrundlage(n) 1 = very good 2 = good P(ass) = passed a.m. test specification(s) 3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n) 3 = satisfactory F(ail) = failed a.m. test specification(s) 4 = ausreichend N/A = nicht anwendbar 4 = sufficient N/A = not applicable 5 = mangelhaft N/T = nicht getestet 5 = poor N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] ·Web: www.tuv.com jjj Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 5.1.1 RADIATED EMISSIONS RESULT: Pass Test Summary Seite 2 von 15 Page 2 of 15 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 Seite 3 von 15 Page 3 of 15 Table of Contents 1 GENERAL REMARKS ...........................................................................................................................4 1.1 COMPLEMENTARY MATERIALS ............................................................................................................4 2 TEST SITES ........................................................................................................................................5 2.1 TEST FACILITIES .................................................................................................................................5 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS.................................................................................5 2.3 TRACEABILITY ....................................................................................................................................5 2.4 CALIBRATION .....................................................................................................................................5 2.5 MEASUREMENT UNCERTAINTY.............................................................................................................5 2.6 LOCATION OF ORIGINAL DATA.............................................................................................................6 2.7 STATUS OF FACILITY USED FOR TESTING.............................................................................................6 3 GENERAL PRODUCT INFORMATION ......................................................................................................7 3.1 PRODUCT FUNCTION AND INTENDED USE.............................................................................................7 3.2 RATINGS AND SYSTEM DETAILS ..........................................................................................................7 3.3 INDEPENDENT OPERATION MODES ......................................................................................................7 3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .........................................................................7 3.5 SUBMITTED DOCUMENTS.....................................................................................................................7 4 TEST SET-UP AND OPERATION MODES ................................................................................................8 4.1 PRINCIPLE OF CONFIGURATION SELECTION .........................................................................................8 4.2 TEST OPERATION AND TEST SOFTWARE ..............................................................................................8 4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................................................8 4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ..........................................................................8 4.5 TEST SETUP DIAGRAM ........................................................................................................................9 5 TEST RESULTS .................................................................................................................................10 5.1.1 Radiated Emissions....................................................................................................................10 6 PHOTOGRAPHS OF THE TEST SET-UP ................................................................................................15 7 LIST OF TABLES................................................................................................................................15 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22N92T 001 Test Report No.: 1 General Remarks Seite 4 von 15 Page 4 of 15 1.1 Complementary Materials All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix A: Photographs of the Test Set-up Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: 2 Test Sites CN22N92T 001 Seite 5 von 15 Page 5 of 15 2.1 Test Facilities TÜV Rheinland (Shenzhen) Co., Ltd. 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China FCC Accreditation Designation No.: CN1260 2.2 List of Test and Measurement Instruments Table 1: List of Test and Measurement Equipment Radiated Emission (3m chamber) Equipment Manufacturer 3m SAC ETS-Lindgren EMI Test Receiver R&S Horn Antenna R&S Preamplifier (1-18GHz) Trilog-Broadband antenna FIT SCHWARZBECK EMC32 test software R&S Model No. SAC3 ESR7 HF907 SCU-18F VULB9168 EMC32(Ver.10.50.00) Serial No. CT001632-Q1362 102111 102706 180077 0945 N/A Cal. Until 2024-04-26 2022-12-01 2022-08-07 2022-08-13 2022-12-12 N/A 2.3 Traceability All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or where calibration is performed in other countries, to equivalent nationally recognized standards organizations. 2.4 Calibration Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. Additionally all equipment is verified for proper performance on a regular basics using in house standards or comparisons. 2.5 Measurement Uncertainty The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements as below table. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 Parameter Radiated Emission (3m SAC), 30MHz to 1000MHz Radiated Emission (3m SAC), above 1000MHz Seite 6 von 15 Page 6 of 15 Uncertainty ± 4.52 dB ± 4.37 dB 2.6 Location of Original Data The original copies of all test data taken during actual testing were attached at Appendix A of this report and delivered to the applicant. A copy has been retained in the TÜV Rheinland (Shenzhen) Co., Ltd. file for certification follow-up purposes. 2.7 Status of Facility Used for Testing The TÜV Rheinland (Shenzhen) Co., Ltd. Test facility located at 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China is listed on the US Federal Communications Commission list of facilities approved to perform measurements. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22N92T 001 Test Report No.: 3 General Product Information 3.1 Product Function and Intended Use The EUT is a Smart terminal. For details refer to the User Manual, Technical Description and Circuit Diagram. 3.2 Ratings and System Details Table 2: Technical Specification of EUT General Information of EUT Kind of Equipment: Type Designation: FCC ID: Operating Voltage: Operating Temperature Range: Euipment Class Value Smart terminal TI5000 2A76R-TI5000 -24 V DC to -36 V DC 0 °C ~ +37 °C Class B Digital device (JAB) Seite 7 von 15 Page 7 of 15 3.3 Independent Operation Modes The basic operation modes are: A. On, Normal working B. Off 3.4 Noise Generating and Noise Suppressing Parts Refer to Circuit Diagram for further details. 3.5 Submitted Documents - User Manual - ID Label and Location Info - Schematics - Operation Description - Block Diagram - PCB Layout Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22N92T 001 Test Report No.: 4 Test Set-up and Operation Modes Seite 8 von 15 Page 8 of 15 4.1 Principle of Configuration Selection Emission: The equipment under test (EUT) was configured to measure its highest possible radiation level. The test modes were adapted accordingly in reference to the instructions for use. 4.2 Test Operation and Test Software Test operation refers to test setup in chapter 5. All tests were performed according to the procedures in ANSI C63.4: 2014. According to clause 3.1, all tests were performed on model TI5000 in this report. 4.3 Special Accessories and Auxiliary Equipment Table 3: Auxiliary Equipment Used during Test Description Manufacturer Model S/N Remark Impacts exchanges Intelbras Impacta 220 N/A Buliding a call between exchange and Smart terminal TI5000 4.4 Countermeasures to Achieve EMC Compliance The test sample which has been tested contained the noise suppression parts as described in the Technical Construction File (TCF). No additional measures were employed to achieve compliance. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 4.5 Test Setup Diagram Diagram of Measurement Configuration for Radiation Test (Below 1GHz) Seite 9 von 15 Page 9 of 15 Diagram of Measurement Configuration for Radiation Test (Above 1GHz) Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22N92T 001 Test Report No.: 5 Test Results Seite 10 von 15 Page 10 of 15 5.1.1 Radiated Emissions RESULT: Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site : FCC Part 15.109(a) : ANSI C63.4:2014 : 30MHz to 5th harmonic of the highest frequency : Class B : FCC Part 15.109(a) : 3m Semi-anechoic Chamber Pass Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure : 2022-07-26 to 2022-08-03 : Powered by Impacts exchanges : A : Refer to test result : Refer to test result : 101 kPa For the measurement records, refer to the following plots. As for above 6GHz, only the noise-floors, thus no record for it. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Smart terminal 168374467 30 TI5000 ON, Normal working Powered by Impacts exchanges FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/50.8%/101kPa 3m chamber Seite 11 von 15 Page 11 of 15 Level in dB/m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Height Pol (dBµV/m) (dBµV/m) (dB) (cm) 47.557000 19.41 40.00 20.59 200.0 H 53.862000 19.52 40.00 20.48 100.0 H 169.389000 20.86 43.50 22.64 100.0 H 437.788000 22.55 46.00 23.45 100.0 H 605.113000 29.27 46.00 16.73 100.0 H 724.617000 30.61 46.00 15.39 200.0 H Azimuth (deg) 55.0 0.0 126.0 298.0 181.0 358.0 Corr. (dB/m) 21.3 21.0 21.7 23.8 27.9 29.5 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Smart terminal 168374467 30 TI5000 ON, Normal working Powered by Impacts exchanges FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/50.8%/101kPa 3m chamber Seite 12 von 15 Page 12 of 15 Level in dB/m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Height Pol (dBµV/m) (dBµV/m) (dB) (cm) 45.908000 20.24 40.00 19.76 100.0 V 56.384000 20.69 40.00 19.31 100.0 V 125.448000 23.08 43.50 20.42 100.0 V 137.767000 23.24 43.50 20.26 100.0 V 143.684000 26.14 43.50 17.36 100.0 V 300.921000 22.47 46.00 23.53 100.0 V Azimuth (deg) 154.0 232.0 244.0 240.0 234.0 354.0 Corr. (dB/m) 20.9 21.2 19.1 20.0 20.2 20.7 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Smart terminal 168374467 30 TI5000 ON, Normal working Powered by Impacts exchanges FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber Seite 13 von 15 Page 13 of 15 Level in dB/m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak Average Limit Margin Height Pol (dBµV/m) (dBµV/m) (dBµV/m) (dB) (cm) 1950.000000 36.32 --- 74.00 37.68 100.0 H 1950.000000 --- 35.38 54.00 18.62 100.0 H 2645.500000 40.32 --- 74.00 33.68 100.0 H 2645.500000 --- 38.50 54.00 15.50 100.0 H 3620.000000 42.07 --- 74.00 31.93 100.0 H 3620.000000 --- 41.37 54.00 12.63 100.0 H 4031.000000 43.17 --- 74.00 30.83 100.0 H 4031.000000 --- 41.51 54.00 12.49 100.0 H 4588.500000 45.15 --- 74.00 28.85 100.0 H 4588.500000 --- 43.80 54.00 10.20 100.0 H 4752.000000 45.06 --- 74.00 28.94 100.0 H 4752.000000 --- 41.74 54.00 12.26 100.0 H Azimuth (deg) 356.0 356.0 305.0 305.0 3.0 3.0 33.0 33.0 91.0 91.0 0.0 0.0 Corr. (dB/m) -7.6 -7.6 -3.3 -3.3 -0.4 -0.4 0.3 0.3 1.9 1.9 2.9 2.9 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Smart terminal 168374467 30 TI5000 ON, Normal working Powered by Impacts exchanges FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber Seite 14 von 15 Page 14 of 15 Level in dB/m Frequency in Hz Critical_Freqs Frequency (MHz) MaxPeak Average Limit Margin Height Pol (dBµV/m) (dBµV/m) (dBµV/m) (dB) (cm) 2072.000000 2072.000000 2281.500000 36.66 --- 37.92 --34.49 --- 74.00 54.00 74.00 37.34 19.51 36.08 100.0 V 100.0 V 100.0 V 2281.500000 2633.000000 2633.000000 3157.500000 --40.24 --40.44 36.44 --- 39.74 --- 54.00 74.00 54.00 74.00 17.56 33.76 14.26 33.56 100.0 V 100.0 V 100.0 V 100.0 V 3158.500000 3738.000000 3738.000000 --42.56 --- 38.32 --- 40.02 54.00 74.00 54.00 15.68 31.44 13.98 100.0 V 100.0 V 100.0 V 4319.500000 4319.500000 45.65 --- --44.13 74.00 54.00 28.35 9.87 100.0 V 100.0 V Azimuth (deg) 193.0 193.0 193.0 193.0 266.0 266.0 124.0 358.0 112.0 112.0 193.0 193.0 Corr. (dB/m) -7.2 -7.2 -6.7 -6.7 -3.5 -3.5 -2.6 -2.6 0.2 0.2 2.2 2.2 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22N92T 001 6 Photographs of the Test Set-Up For photographs of the test set-up, refer to the appendix A. Seite 15 von 15 Page 15 of 15 7 List of Tables Table 1: List of Test and Measurement Equipment..................................................................... 5 Table 2: Technical Specification of EUT ..................................................................................... 7 Table 3: Auxiliary Equipment Used during Test .......................................................................... 8
Related FCC IDs:
- 2A76R-TI5000 - Intelbras Industria de Telecomunicacao Eletronica Brasileira TI5000 [-TI5000] Microsoft Word 2016; modified using iText 4.2.2 by 1T3XT, AuthentiDate