Shenzhen Sunspring Electronics Co., Ltd.

Keyboard

OJWCG107C

Violet Wang

Test Report 2G4SRD

Kezhi(HuiZhou) Electronic Technology Co., Ltd. Z98 2BBA6-Z98 2BBA6Z98 z98

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 35 Pages, 1.75MB

Document DEVICE REPORTGetApplicationAttachment.html?id=6779353
Page 1 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

FCC TEST REPORT
FOR
KeZhi(HuiZhou) Electronic Technology Co., Ltd. Mechanical keyboard Test Model: Z98
Additional Model No.: Z98Pro, Z98Plus, 752

Prepared for
Address
Prepared by
Address
Tel Fax Web Mail
Date of receipt of test sample Number of tested samples Sample No. Sample number Date of Test Date of Report

: KeZhi(HuiZhou) Electronic Technology Co., Ltd.

:

Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou City, Guangdong Province, China

: Shenzhen LCS Compliance Testing Laboratory Ltd

:

101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China

: (+86)755-82591330

: (+86)755-82591332

: www.LCS-cert.com

: [email protected]

: August 08, 2023 :2 : A08083023-1, A08083023-2 : Prototype : August 08, 2023 ~ August 28, 2023 : August 28, 2023

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 2 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

FCC TEST REPORT FCC CFR 47 PART 15 C (15.249)

Report Reference No. .....................: LCSA08083023EB

Date of Issue....................................... : August 28, 2023

Testing Laboratory Name.............. : Shenzhen LCS Compliance Testing Laboratory Ltd.

Address................................................

:

101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China

: Full application of Harmonised standards  Testing Location/ Procedure............ Partial application of Harmonised standards 
Other standard testing method 

Applicant's Name............................. : KeZhi(HuiZhou) Electronic Technology Co., Ltd.
Address................................................ : Main building No.8, Minying 1st road, Yuanzhou Town, Boluo County, Huizhou City, Guangdong Province, China
Test Specification

Standard.............................................. : FCC CFR 47 PART 15 C(15.249) / ANSI C63.10: 2013

Test Report Form No......................... : LCSEMC-1.0 TRF Originator.................................... : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF......................................... : Dated 2011-03

Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

Test Item Description..................... : Mechanical keyboard

Trade Mark.......................................... : ,
Test Model........................................... : Z98 Ratings................................................. : Input: 5V 200mA(MAX)
DC 3.7V by Rechargeable Li-ion Battery, 3750mAh
Result ..................................................: Positive

Compiled by:

Supervised by:

Approved by:

Li Huan/Administrator

Cary Luo/ Technique principal

Gavin Liang/ Manager

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 3 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Test Report No. :

FCC -- TEST REPORT
LCSA08083023EB

August 28, 2023 Date of issue

Test Model.............................. : Z98

EUT......................................... : Mechanical keyboard

Applicant............................... Address.................................. Telephone...............................

: KeZhi(HuiZhou) Electronic Technology Co., Ltd.

:

Main building No.8, Minying 1st road, Yuanzhou Town, County, Huizhou City, Guangdong Province, China

Boluo

:/

Fax.......................................... : /

Manufacturer........................ Address...................................

: KeZhi(HuiZhou) Electronic Technology Co., Ltd. Main building No.8, Minying 1st road, Yuanzhou Town, Boluo
: County, Huizhou City, Guangdong Province, China

Telephone............................... : /

Fax.......................................... : /

Factory................................... Address...................................

: KeZhi(HuiZhou) Electronic Technology Co., Ltd. Main building No.8, Minying 1st road, Yuanzhou Town, Boluo
: County, Huizhou City, Guangdong Province, China

Telephone............................... : /

Fax.......................................... : /

Test Result

Positive

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 4 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Report Version
000

Revision History

Issue Date
August 28, 2023

Revision Content
Initial Issue

Revised By
---

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 5 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

TABLE OF CONTENTS

1. GENERAL INFORMATION.............................................................................................6 1.1 Description of Device (EUT).................................................................................................. 6 1.2. Support Equipment List......................................................................................................... 7 1.3. External I/O..............................................................................................................................7 1.4. Description of Test Facility....................................................................................................7 1.5. Statement of the measurement uncertainty....................................................................... 7 1.6. Measurement Uncertainty..................................................................................................... 7 1.7. Description of Test Modes.................................................................................................... 8
2. TEST METHODOLOGY...................................................................................................9 2.1. EUT Configuration..................................................................................................................9 2.2. EUT Exercise.......................................................................................................................... 9 2.3. General Test Procedures...................................................................................................... 9
3. CONNECTION DIAGRAM OF TEST SYSTEM.........................................................10 3.1. Justification............................................................................................................................10 3.2. EUT Exercise Software....................................................................................................... 10 3.3. Special Accessories.............................................................................................................10 3.4. Block Diagram/Schematics.................................................................................................10 3.5. Equipment Modifications..................................................................................................... 10 3.6. Test Setup............................................................................................................................. 10
4. SUMMARY OF TEST RESULTS................................................................................. 11
5. ANTENNA REQUIREMENT......................................................................................... 12
6. POWER LINE CONDUCTED EMISSIONS................................................................ 13
7. RADIATED EMISSION MEASUREMENT..................................................................16
8. RESULTS FOR BAND EDGE TESTING....................................................................26
9. 20 DB BANDWIDTH MEASUREMENT......................................................................32
10. LIST OF MEASURING EQUIPMENT....................................................................... 34
11. TEST SETUP PHOTOGRAPHS OF THE EUT....................................................... 35
12. EXTERIOR PHOTOGRAPHS OF THE EUT........................................................... 35
13. INTERIOR PHOTOGRAPHS OF THE EUT.............................................................35

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 6 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

1. GENERAL INFORMATION

1.1 Description of Device (EUT)

EUT

: Mechanical keyboard

Test Model

: Z98

Additional Model No. Model Declaration Power Supply

: Z98Pro, Z98Plus, 752

:

PCB board, structure and internal additional models were tested

of

these

model(s)

are

the

same,

So

no

: Input: 5V 200mA(MAX)

DC 3.7V by Rechargeable Li-ion Battery, 3750mAh

Hardware Version

: V1.1

Software Version

: 0103

Bluetooth

:

Frequency Range

: 2402MHz~2480MHz

Channel Number

: 40 channels for Bluetooth V5.0 (DTS)

Channel Spacing

: 2MHz for Bluetooth V5.0 (DTS)

Modulation Type

: GFSK for Bluetooth V5.0 (DTS)

Bluetooth Version

: V5.0

Antenna Description : PCB Antenna, 1.22dBi(Max.)

2.4G

:

Frequency Range

: 2402MHz~2480MHz

Channel Number Channel Spacing

: 40 channels : 2MHz

Modulation Type Antenna Description

: GFSK : PCB Antenna, 1.23dB(max.)

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 7 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

1.2. Support Equipment List

Manufacturer

Description

Model

SHENZHEN TIANYIN ELECTRONICS CO., LTD

Power Adapter

TPA-46050200 UU

Note: Auxiliary equipment is provided by the laboratory.

Serial Number --

Certificate FCC

1.3. External I/O
I/O Port Description Type-C Port USB Port

Quantity 2 1

Cable N/A N/A

1.4. Description of Test Facility
NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912

The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

1.5. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 ­ 4 "Specification for radio disturbance and immunity measuring apparatus and methods ­ Part 4: Uncertainty in EMC Measurements" and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

1.6. Measurement Uncertainty

Test Item
Radiation Uncertainty :
Conduction Uncertainty : Power disturbance : Occupied Channel : Bandwidth

Frequency Range 9KHz~30MHz
30MHz~200MHz 200MHz~1000MHz
1GHz~26.5GHz 26.5GHz~40GHz 150kHz~30MHz 30MHz~300MHz
1GHz-40GHz

Uncertainty ±3.10dB ±2.96dB ±3.10dB ±3.80dB ±3.90dB ±1.63dB ±1.60dB ±5%

Note (1) (1) (1) (1) (1) (1) (1) (1)

(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 8 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

1.7. Description of Test Modes
Operates in the unlicensed ISM Band at 2.4GHz. With basic data rate feature, the data rates can be up to 1 Mb/s by modulating the RF carrier using GFSK techniques. The EUT works in the X-axis, Y-axis, Z-axis. The following operating modes were applied for the related test items. All test modes were tested, only the result of the worst case was recorded in the report.

Mode of Operations

Frequency Range (MHz)

2402

GFSK

2440

2480

For Conducted Emission

Test Mode

For Radiated Emission

Test Mode

Data Rate (Mbps) / / /
TX Mode
TX Mode

Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel with the highest output power, that was determined to be TX.

Channel List:

Frequency Band 2402~2480MHz

Channel No. 0 1 2 --19

Frequency(MHz) 2402 2404 2406 --2440

Channel No. 20 --37 38 39

Frequency(MHz) 2442 --2476 2478 2480

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 9 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

2. TEST METHODOLOGY
All measurements contained in this report were conducted with ANSI C63.10: 2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd.
2.1. EUT Configuration
The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application.
2.2. EUT Exercise
The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205, 15.207, 15.209 and 15.249 under the FCC Rules Part 15 Subpart C.
2.3. General Test Procedures

2.3.1 Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane.According to the requirements in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.
2.3.2 Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane below 1GHz and 1.5 m above ground plane above 1GHz.The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10-2013

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 10 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

3. CONNECTION DIAGRAM OF TEST SYSTEM

3.1. Justification
The system was configured for testing in a continuous transmit condition. Continuous transmitting was pre-programmed. It'll keep transmitting with modulated signal at the lowest channel by installing the batter. When press the "up" button, it'll move to the next channel. Repeat press "up" button, it'll transmitting at each of the channel used.
3.2. EUT Exercise Software
Press the corresponding button, and change the channel.Power setting Default.
3.3. Special Accessories
N/A
3.4. Block Diagram/Schematics
Please refer to the related document
3.5. Equipment Modifications
Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.
3.6. Test Setup
Please refer to the test setup photo.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 11 of 35

FCC ID: 2BBA6-Z98

4. SUMMARY OF TEST RESULTS

Report No.: LCSA08083023EB

Applied Standard: FCC Part 15 Subpart C §15.249

FCC Rules §15.203
§15.207(a)

Description Of Test Antenna Requirement Power Line Conducted Emissions

§15.205(a), §15.209(a), §15.249(a), §15.249(c) Radiated Emissions Measurement

§15.249 (d) §15.215(c)

Band Edges Measurement 20 dB Bandwidth

Result Compliant Compliant
Compliant Compliant Compliant

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 12 of 35

FCC ID: 2BBA6-Z98

5. ANTENNA REQUIREMENT

Report No.: LCSA08083023EB

5.1. Standard Applicable
According to § 15.203 and RSS-Gen, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
5.2. Antenna Connected Construction
The EUT use Internal Antenna and maximum antenna gain is 1.23 dBi, antenna cannot replacement, meets FCC Part §15.203 antenna requirement. Please see EUT photo for details.
5.3. Results
Compliance

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 13 of 35

FCC ID: 2BBA6-Z98

6. POWER LINE CONDUCTED EMISSIONS

Report No.: LCSA08083023EB

6.1. Standard Applicable
According to §15.207 (a) & RSS-Gen § 8.8: For an intentional radiator which is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range are listed as follows:

Frequency Range (MHz)
0.15 to 0.50 0.50 to 5 5 to 30

Limits (dBV)

Quasi-peak

Average

66 to 56

56 to 46

56

46

60

50

* Decreasing linearly with the logarithm of the frequency

6.2. Block Diagram of Test Setup

Vert. reference plane

EMI receiver

EUT

LISN

6.3. Test Results
PASS. The test data please refer to following page.

Temperature Test Engineer

23.5 Nick Peng

Reference ground plane

Humidity

53.6%

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 14 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

AC Conducted Emission of Adapter @ AC 120V/60Hz @ GFSK (High Channel) (worst case)

Line

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 15 of 35 Neutral

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

***Note: Pre-scan all modes and recorded the worst case results in this report GFSK (High Channel). Measurement= Reading + Correct Factor, Margin = Measurement ­ Limit. Correct Factor=Lisn Factor+Cable Factor
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 16 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

7. RADIATED EMISSION MEASUREMENT
7.1. Standard Applicable
According to FCC § 15.249: Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209, whichever is the lesser attenuation.
20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) and 15.249 limit in the table below has to be followed.

Fundamental Frequency 902-928MHz
2400-2483.5MHz 5725-5875MHz 24.0-24.25GHz

Field Strength of fundamental (millivolts/meter) 50 50 50 250

Field Strength of harmonics (microvolts/meter) 500 500 500 2500

Frequencies (MHz)
0.009~0.490 0.490~1.705 1.705~30.0
30~88 88~216 216~960 Above 960

Field Strength (microvolts/meter)
2400/F(KHz) 24000/F(KHz)
30 100 150 200 500

Measurement Distance (meters) 300 30 30 3 3 3 3

According to RSS-210 B.10:
The field strength of fundamental and harmonic emissions, measured at 3 m, shall not exceed 50 mV/m and 0.5 mV/m respectively.
The field strength limits shall be measured using an average detector, except for the fundamental emission in the frequency band 902-928 MHz, which is based on measurements using an International Special Committee on Radio Interference (CISPR) quasi-peak detector.
Emissions radiated outside of the specified frequency bands, except for harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental emissions or to the general field strength limits listed in RSS-Gen, whichever is less stringent.

7.2. Instruments Setting
Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and receiver.

Spectrum Parameter Attenuation Start Frequency Stop Frequency RB / VB (Emission in restricted band) RB / VB (Emission in non-restricted band)

Setting Auto 1000 MHz 10th carrier harmonic 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 17 of 35
Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency
7.3. Test Procedure

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Setting Auto 9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG 150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG 30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

1) Sequence of testing 9 kHz to 30 MHz
Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used. --- If the EUT is a floor standing device, it is placed on the ground. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions. --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation.
Premeasurement: --- The turntable rotates from 0° to 315° using 45° steps. --- The antenna height is 1.0 meter. --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions
Final measurement: --- Identified emissions during the premeasurement the software maximizes by rotating the turntable position (0° to 360°) and by rotating the elevation axes (0° to 360°). --- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector. --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.

2) Sequence of testing 30 MHz to 1 GHz
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 18 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation.
Premeasurement: --- The turntable rotates from 0° to 315° using 45° steps. --- The antenna is polarized vertical and horizontal. --- The antenna height changes from 1 to 3 meter. --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions.
Final measurement: --- The final measurement will be performed with minimum the six highest peaks. --- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. --- The final measurement will be done with QP detector with an EMI receiver. --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored.

3) Sequence of testing 1 GHz to 18 GHz
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 19 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation.

Premeasurement: --- The turntable rotates from 0° to 315° using 45° steps. --- The antenna is polarized vertical and horizontal. --- The antenna height scan range is 1 meter to 2.5 meter. --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions.

Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 20 of 35

FCC ID: 2BBA6-Z98

4) Sequence of testing above 18 GHz

Report No.: LCSA08083023EB

Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 1 meter. --- The EUT was set into operation.

Premeasurement: --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

Final measurement:
--- The final measurement will be performed at the position and antenna orientation for all detected emissions that were found during the premeasurements with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 21 of 35

FCC ID: 2BBA6-Z98

7.4. Block Diagram of Test Setup

Report No.: LCSA08083023EB

Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade form 3m to 1m.
7.5 EUT Operation during Test
The EUT was programmed to be in continuously transmitting mode.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 22 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

7.6. Test Results of Radiated Emissions (9 KHz~30 MHz)

Temperature Test Engineer

23.8 Nick Peng

Humidity

52.1%

Freq. (MHz)
-

Level (dBuV)
-

Over Limit (dB)
-

Over Limit (dBuV)
-

Remark See Note

Note: The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value has no need to be reported.

7.7. Test Results of Radiated Emissions (30 MHz ­ 1000 MHz)

Temperature Test Engineer
Vertical

23.8 Nick Peng

Humidity

52.1%

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Horizontal

Page 23 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Note: 1). Pre-scan all modes and recorded the worst case results in this report GFSK (High Channel). 2). Emission level (dBuV/m) = 20 log Emission level (uV/m). 3). Level = Reading + Factor, Margin = Level ­ Limit,
Factor = Antenna Factor + Cable Loss - Preamp Factor
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 24 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

7.8. Results for Radiated Emissions (1 ­ 26 GHz)

2402 MHz

Frequency Pol.

(MHz)

2402

H

2402

V

Field Strength of Fundamental (TX-2402 MHz)

Measure Result

Measure Result

Peak Limit

(PK, dBuV/m)

(AVG, dBuV/m)

(dBuV/m)

74.04

68.66

114

71.39

68.19

114

AVG Limit (dBuV/m)
94 94

Result
Pass Pass

Freq. MHz
4804.00 4804.00 4804.00 4804.00

Reading Level dBuV 54.73 44.28 58.07 43.86

Ant. Fac. dB/m 33.06 33.06 33.06 33.06

Pre. Fac. dB 35.04 35.04 35.04 35.04

Cab. Loss dB 3.94 3.94 3.94 3.94

Measured dBuV/m
56.69 46.24 60.03 45.82

Limit dBuV/m
74.00 54.00 74.00 54.00

Margin dB
-17.31 -7.76 -13.97 -8.18

Remark

Pol.

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

2440 MHz

Frequency Pol.

(MHz)

2440

H

2440

V

Field Strength of Fundamental (TX-2402 MHz)

Measure Result

Measure Result

Peak Limit

(PK, dBuV/m)

(AVG, dBuV/m)

(dBuV/m)

73.98

68.64

114

71.29

68.19

114

AVG Limit (dBuV/m)
94 94

Result
Pass Pass

Freq. MHz
4880.00 4880.00 4880.00 4880.00

Reading Level dBuV 55.07 44.44 60.85 45.23

Ant. Fac. dB/m 33.16 33.16 33.16 33.16

Pre. Fac. dB 35.15 35.15 35.15 35.15

Cab. Loss dB 3.96 3.96 3.96 3.96

Measured dBuV/m
57.04 46.41 62.82 47.20

Limit dBuV/m
74.00 54.00 74.00 54.00

Margin dB
-16.96 -7.59 -11.18 -6.80

Remark

Pol.

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

2480 MHz

Frequency Pol.

(MHz)

2480

H

2480

V

Field Strength of Fundamental (TX-2402 MHz)

Measure Result

Measure Result

Peak Limit

(PK, dBuV/m)

(AVG, dBuV/m)

(dBuV/m)

76.41

69.75

114

74.50

69.29

114

AVG Limit (dBuV/m)
94 94

Result
Pass Pass

Freq. MHz
4960.00 4960.00 4960.00 4960.00

Reading Level dBuV 60.88 43.66 53.87 44.06

Ant. Fac. dB/m 33.26 33.26 33.26 33.26

Pre. Fac. dB 35.14 35.14 35.14 35.14

Cab. Loss dB 3.98 3.98 3.98 3.98

Measured dBuV/m
62.98 45.76 55.97 46.16

Limit dBuV/m
74.00 54.00 74.00 54.00

Margin dB
-11.02 -8.24 -18.03 -7.84

Remark

Pol.

Peak Average
Peak Average

Horizontal Horizontal
Vertical Vertical

Notes:
1). Measuring frequencies from 9 KHz - 10th harmonic (ex. 26GHz), No emission found between lowest internal used/generated frequency to 30 MHz.
2). Radiated emissions measured in frequency range from 9 KHz - 10th harmonic (ex. 26GHz) were made with an instrument using Peak detector mode.

3). 18~25 GHz at least have 20dB margin. No recording in the test report.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 25 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

4). Measured Level = Reading Level + Factor, Margin = Level ­ Limit, Factor = Antenna Factor + Cable Loss - Preamp Factor

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 26 of 35

FCC ID: 2BBA6-Z98

8. RESULTS FOR BAND EDGE TESTING

Report No.: LCSA08083023EB

8.1. Standard Applicable
According to FCC §15.249 (d): Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209, whichever is the lesser attenuation.
According to RSS-210 B.10 (b): Emissions radiated outside of the specified frequency bands, except for harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental emissions or to the general field strength limits listed in RSS-Gen, whichever is less stringent.
8.2. Test Setup Layout

8.3. Measuring Instruments and Setting
Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.
8.4. Test Procedures
3) Sequence of testing 1 GHz to 18 GHz
Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used. --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both. --- Auxiliary equipment and cables were positioned to simulate normal operation conditions --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable. --- The measurement distance is 3 meter. --- The EUT was set into operation.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 27 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Premeasurement: --- The turntable rotates from 0° to 315° using 45° steps. --- The antenna is polarized vertical and horizontal. --- The antenna height scan range is 1 meter to 2.5 meter. --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions.

Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored.

8.5. Measuring Instruments and Setting

Temperature Test Engineer

23.5 Nick Peng

Humidity

52.1%

PASS

Remark: 1. The other emission levels were very low against the limit. 2. The average measurement was not performed when the peak measured data under the limit of average
detection. 3. Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=330Hz/Sweep time=Auto/Detector=Peak; 4. Please refer to following test plots;

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 28 of 35 Channel 1/ 2402 MHz Horizontal

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 29 of 35 Channel 1 / 2402 MHz Vertical

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 30 of 35 Channel 39 / 2480 MHz Horizontal

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 31 of 35 Channel 39 / 2480 MHz Vertical

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 32 of 35

FCC ID: 2BBA6-Z98

9. 20 DB BANDWIDTH MEASUREMENT

Report No.: LCSA08083023EB

9.1. Standard Applicable
§15.215 (c) Intentional radiators operating under the alternative provisions to the general emission
limits, as contained in §§15.217 through 15.257 and in subpart E of this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated. In the case of intentional radiators operating under the provisions of subpart E, the emission bandwidth may span across multiple contiguous frequency bands identified in that subpart. The requirement to contain the designated bandwidth of the emission within the specified frequency band includes the effects from frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a frequency stability is not specified in the regulations, it is recommended that the fundamental emission be kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of-band operation.
9.2. Block Diagram of Test Setup

9.3. Test Procedure
Use the following spectrum analyzer settings: Span = 3MHz RBW = 51 kHz VBW = 150 KHz Sweep = auto Detector function = peak Trace = max hold The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function to measure 20 dB down one side of the emission. Reset the marker-delta function, and move the marker to the other side of the emission, until it is (as close as possible to) even with the reference marker level. The marker-delta reading at this point is the 20 dB bandwidth of the emission. If this value varies with different modes of operation (e.g., data rate, modulation format, etc.), repeat this test for each variation. The limit is specified in one of the subparagraphs of this Section. Submit this plot(s).
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 33 of 35
9.4. Test Results
Temperature Test Engineer

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

23.5 Nick Peng

Humidity

52.1%

Test Result of 20dB Bandwidth Measurement

Test Frequency

20dB Bandwidth

Limit

(MHz)

(MHz)

(MHz)

2402

1.116

Non-Specified

2440

1.115

Non-Specified

2480

1.117

Non-Specified

Remark:

1. Test results including cable loss;

2. Please refer following test plots;

GFSK

20dB Bandwidth

GFSK

2402 MHz

2440 MHz

2480 MHz
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 34 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

10. LIST OF MEASURING EQUIPMENT

Item

Equipment

1

MXA Signal Analyzer

2

DC Power Supply

3

Temperature & Humidity Chamber

4

EMI Test Software

5

3m Semi Anechoic Chamber

6

Positioning Controller

7

Active Loop Antenna

8

By-log Antenna

9

Horn Antenna

10

EMI Test Receiver

11

RS SPECTRUM ANALYZER

12

Broadband Preamplifier

13

EMI Test Receiver

14

Artificial Mains

15

10dB Attenuator

16

EMI Test Software

Manufacturer Agilent Agilent
GUANGZHOU GOGNWEN AUDIX
SIDT FRANKONIA Max-Full
SCHWARZBECK SCHWARZBECK SCHWARZBECK
R&S R&S
/
R&S
R&S SCHWARZBECK
Farad

Model No. N9020A E3642A
GDS-100
E3 SAC-3M MF7802BS FMZB 1519B VULB9163 BBHA 9120D ESR 7 FSP40 BP-01M18G
ESPI
ENV216 MTS-IMP-136
EZ

Serial No. MY49100060
N/A
70932
/ 03CH03-HY MF780208586
00005 9163-470 9120D-1925 101181 100503 P190501
101940
101288 261115-001-0032
/

Cal Date 2022-10-29 2022-10-29
2022-10-06
N/A 2023-06-09
N/A 2021-08-29 2021-09-12 2021-09-05 2023-06-09 2022-10-29 2023-06-09 2022-08-16 2023-08-15 2023-06-09 2023-06-09
N/A

Due Date 2023-10-28 2023-10-28
2023-10-05
N/A 2024-06-08
N/A 2024-08-28 2024-09-11 2024-09-04 2024-06-08 2023-10-28 2024-06-08 2023-08-15 2024-08-14 2024-06-08 2024-06-08
N/A

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 35 of 35

FCC ID: 2BBA6-Z98

Report No.: LCSA08083023EB

11. TEST SETUP PHOTOGRAPHS OF THE EUT
Please refer to separated files for Test Setup Photos of the EUT.
12. EXTERIOR PHOTOGRAPHS OF THE EUT
Please refer to separated files for External Photos of the EUT.
13. INTERIOR PHOTOGRAPHS OF THE EUT
Please refer to separated files for Internal Photos of the EUT.

------------THE END OF REPORT----------
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity



Related FCC IDs:

Search Any Device: