Jackson Dishwasher Tempstar HH Spec Sheet

Jackson, Dishwasher, Jackson Tempstar HH, Jackson Spec Sheet, Tempstar HH Spec Sheet

Central Restaurant Products

https://assets.centralrestaurant.com/pdfs/specsheets/670-040

Jackson Tempstar Hh Manual

Spec Sheet

Jackson TempStar - HH VL - Ventless High Hood Door Type Dishwasher, 208V, 3 Phase

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 2 Pages, 277.19KB

Document DEVICE REPORT670-040
TempStar® HH


TempStar® HH

Project Item Quantity CSI Section 11400 Approval Date

Models
TempStar® HH
Specifications
Uses 1.36 gallons (5 liters) of 180°F (82°C) water per rack Total automatic (normal) cycle - 62 seconds 53 racks per hour (normal) cycle 2 HP Wash Pump Motor

Standard Features
· Sani-SureTM feature assures proper rinse water temperature
· Multi-cycle timer (Extra Heavy, Heavy, Medium, Normal)
· Extended 15sec. high-temperature rinse provides superior coverage and rapid drying
· 20-3/4" wide X 27" high (527mm X 686mm) opening accommodates 18" X 26" (457mm X 660mm) sheet pans and 60-quart mixing bowls
· Auto-fill / auto-start · Door switch · Delime/manual wash switch · Low watt density electric wash
tank heater · Hi-limit thermostat and low water
protection · Vent fan control shuts fan off when
machine is idle · Adjustable bullet feet · Uses standard 20" X 20" (508 mm X
508 mm) racks · Front dress panel · Detergent/rinse additive signal
connection fuse box · Built-in 70° F (38.9° C) rise booster
heater is standard; 40° F (22.2° C) rise booster heater is available but must be specified at time of order · Lower counter-rotating wash arms and upper wash arm provide optimum spray coverage and superior cleaning action · Self-draining stainless steel pump · Split-door design accommodates installations with low ceiling heights · Large scrap basket

Mandatory Specs
Specify: Electric Steam
Specify voltage ______________ Specify booster size __________
Options
Optional 40° F (22.2° C) rise booster heater is available at no additional cost (must be specified)
Drain Quench System Scaltrol 3/4" Pressure Regulator Flanged Feet Water Hammer Arrestor 480V Electrical Single Phase Security Package False Panel Door Interlock Steam Booster Heater
Accessories
36-Compartment Rack
4-1/8" tall (105 mm) 5-5/8" tall (143 mm) 7" tall (178 mm)
Combination Rack Peg Rack Sheet Pan Rack - for 18" X 26" (457mm X 660mm) baking pans

Single point connections for all utilities
Field convertible from straight through to corner and vice versa
Heavy duty stainless steel construction

www.jacksonwws.com

TempStar® HH


LEGEND A - DRAIN 1 1/2" IPS B - WATER INLET 3/4" IPS C - ELECTRICAL CONNECTION All vertical dimensions are +/- 1/2" due to adjustable bullet feet.
4 [101mm]

2541 [639mm] 3 [79mm]
C

1 [27mm]

25 [637mm] 17 [432mm]

B

8634 [2202mm]

C

B

73 [1856mm]

7341 [1863mm] 27 [687mm]

3 [76mm] A

B 4 [102mm]

1134 [298mm]

A

1541 [387mm]

34 [861mm]

MACHINE DIMENSIONS

MODEL NO.

HEIGHT

WIDTH

DEPTH

DRAIN
 SHIPPING INFORMATION HEIGHT
 WEIGHT CLASS CUBE

HEIGHT

WIDTH

DEPTH

TempStar® HH

76-3/4" (1949 mm)

25-1/4" (641 mm)

25-1/4" (641 mm)

11-3/4" 420 lbs (298 mm) (191 kg)

92.5

77.7 cu. ft.

83" (2108 mm)

33" (838 mm)

49"
 (1245 mm)


DIMENSION REQUIREMENTS

STEAM REQUIREMENTS

Minimum Ceiling Height (recommended)

88" (2 meters)

Steam Flow Pressure (PSIG)

Wall Clearance (minimum)

4" (102 mm)

Consumption @ 15 PSIG (Ibs/hr)

Standard Table Height Inside Clearance

34" (864 mm) 27" (686 mm)

WATER REQUIREMENTS Inlet Temperature 


OPERATING CAPACITY Racks per Hour
OPERATING CYCLE (seconds) Normal
 Medium
 Heavy
 Extra Heavy
 OPERATING TEMPERATURES
 Wash (minimum)
 Rinse (minimum)

WASH PUMP MOTOR Wash Pump Motor Horsepower

Normal
 Medium

53


28

Wash
 Rinse

45


15

103


15

163


15

283


15

Heavy 19
Dwell 2 2 2
2

Extra Heavy 11
Total Cycle 62 120 180
300

150° F (66° C) 180° F (82° C)

40°F (22.2°C) Rise
 70°F (38.9°C) Rise
 No Booster
 Gallons per Hour Gallons per Rack Waterline Size IPS (minimum) Drainline Size IPS (minimum) Flow Pressure (PSI) Tank Capacity Wash Tank Capacity Booster Tank Capacity

2 HP

APPROXIMATE LOAD AMPS

Volts

KW

No Booster

Electric Wash Tank Heater

208V

4.1

Power Supply


AMPS

230V

5.0

208V/60HZ/1PH


30.9

460V

5.0

208V/60HZ/3PH


22.6

Electric Rinse Tank Heater - 40°F (22.2°C) Rise Electric Rinse Tank Heater - 70°F (38.9°C) Rise

208V 230V 460V 208V 230V

9.0

230V/60HZ/1PH


33.0

11.0

230V/60HZ/3PH


23.8

11.0

460V/60HZ/3PH


9.6

10.5

HOW TO SPECIFY: TempStar® HH

12.9

460V

12.9

15-20 45

140°F (60°C)
 110°F (43°C)
 180°F (82°C)
 72.1 gal (273 L)
 1.36 gal (5 L)

3/4"
 1- 1/2"
 15-25
 3 gal (11 L) 8 gal (30 L) 3 gal (11 L)

40°F (22.2°C) Rise AMPS 74.2 47.6 80.9 51.4 23.4

70°F (38.9°C) Rise AMPS 81.4 51.8 89.0 56.2 25.8

Jackson WWS, Inc.
Shipping Address: 6209 North U.S. Highway 25E, Gray, KY 40734 Mailing Address: P.O.Box 1060, Barbourville, KY 40906 Telephone: 888-800-5672 · Fax: 606-523-1799 Email: [email protected] 07610-002-66-60B [02/26/15]

www.jacksonwws.com

We reserve the right to change specifications in this bulletin without incurring any obligation for equipment previously or subsequently sold.


Adobe PDF library 10.01

Search Any Device: