75940792 Report 01 Issue 01 Draft 3
baile-na
RF Exposure info
Nokia Solutions and Networks AHFIB-01 Remote Radio Head VBNAHFIB-01 VBNAHFIB01 ahfib 01
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 34 Pages, 259.99KB
Document DEVICE REPORTGetApplicationAttachment.html?id=4176798Report On RF Exposure Assessment of the Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) Document 75940792 Report 01 Issue 1 December 2017 TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk REPORT ON PREPARED FOR PREPARED BY APPROVED BY DATED RF Exposure Assessment of the Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) Document 75940792 Report 01 Issue 1 December 2017 Nokia Solutions and Networks Oy Kaapelitie 4 Oulu Finland Maggie Whiting Project Manager Matthew Russell Authorised Signatory 12 December 2017 Document 75940792 Report 01 Issue 1 Page 1 of 30 Section CONTENTS Page No 1 1.1 1.2 1.3 1.3.1 1.3.2 1.3.3 1.3.4 1.4 1.4.1 1.4.2 1.4.3 1.4.4 1.4.5 1.4.6 1.4.7 1.4.8 1.4.9 1.4.10 1.4.11 1.4.12 2 2.1 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.2.7 2.2.8 2.2.9 2.2.10 2.2.11 2.2.12 3 3.1 REPORT SUMMARY ................................................................................................................... 3 Introduction .................................................................................................................................... 4 Regional Requirements ................................................................................................................. 5 Product Information ....................................................................................................................... 6 Technical Description .................................................................................................................... 6 Supported Features ....................................................................................................................... 6 Antennas........................................................................................................................................ 6 EUT Configurations ....................................................................................................................... 7 Brief Summary of Results .............................................................................................................. 8 Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) ............................................ 9 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3)..................................................... 10 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25) ................................................ 11 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25) .............................................. 12 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 13 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3)..................................................... 14 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14) ................................................ 15 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71) ................................................ 16 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 17 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a) .............................................. 18 Configuration 11 - 1 band, 4 TX antenna connectors (B28)........................................................ 19 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70) ................................................ 20 TEST DETAILS .......................................................................................................................... 21 Rationale for Assessment of the RF Exposure ........................................................................... 22 Test Result Details....................................................................................................................... 23 Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) .......................................... 23 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3)..................................................... 23 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25) ................................................ 24 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25) .............................................. 24 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 25 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3)..................................................... 25 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14) ................................................ 26 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71) ................................................ 26 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 27 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a) .............................................. 27 Configuration 11 - 1 band, 4 TX antenna connectors (B28)........................................................ 28 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70) ................................................ 28 DISCLAIMERS AND COPYRIGHT............................................................................................ 29 Disclaimers and Copyright........................................................................................................... 30 Document 75940792 Report 01 Issue 1 Page 2 of 30 SECTION 1 REPORT SUMMARY RF Exposure Assessment of the Nokia Solutions and Networks AirScale Base Station Products and Flexi Multiradio Station Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) Document 75940792 Report 01 Issue 1 Page 3 of 30 1.1 INTRODUCTION The information contained in this report is intended to show verification of the RF Exposure Assessment of the Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) to the requirements of the applied test specifications. Objective Applicant Manufacturer Manufacturing Description Model Number(s) Test Specification/Issue/Date Related Documents To perform RF Exposure Assessment to determine the Equipment Under Test's (EUT's) compliance of the applied rules. Nokia Solutions and Networks Nokia Solutions and Networks Oy AirScale Base Station Products and Flexi Multiradio Base Station Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) AirScale and Flexi Multiradio Base Station Multiband Products EN 62311:2008 CFR 47 Pt1.1310 (2016) Health Canada Safety Code 6 ARPANSA Radiation Protection Series No.3 EN 50385: 2017 Document 75940792 Report 01 Issue 1 Page 4 of 30 1.2 REGIONAL REQUIREMENTS The table below shows the regional requirements that are referenced in this test report. A full list of the requirements is shown in Annex A. Report Reference EU FCC IC AUS Regional Requirement EN 62311:2008 CFR 47 Pt1.1310 (2016) Health Canada Safety Code 6 ARPANSA Radiation Protection Series No.3 Document 75940792 Report 01 Issue 1 Page 5 of 30 1.3 PRODUCT INFORMATION 1.3.1 Technical Description The Equipment under test was a Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71). A full technical description can be found in the manufacturer's documentation. All reported calculations were carried out on the relevant information supplied for the AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) to demonstrate compliance with the applied test specification(s). The sample assessed was found to comply with the requirements of the applied rules. 1.3.2 Supported Features The following radio access technologies and frequency bands are supported by the equipment under test. Radio Access Technology LTE (120W) LTE (160W) LTE (200W) LTE (240W) LTE (320W) Frequency Band Band 8 + Band 20 + Band 28 (758-960) Band 1 + Band 3 (1805-2170) Band 66 + Band 25 (1930-2200) Band 66a + Band 25 (1930-2180) Band 5 + Band 13 (746-894) Band 12 + Band 14 (729-768) Band 12 + Band 71 (617-746) Band 2 + Band 66a (1930-2180) Band 28 (758-803) Band 66a (2110-2180) Band 1+ Band 3 (1805-2170) Band 28+Band 20 (758-821) Band 29 + Band 70 (717-2020) 1.3.3 Antennas The following antennas are supported by the equipment under test. No. Model Gain(dB) 1 Not Supplied 16.4 Document 75940792 Report 01 Issue 1 Page 6 of 30 1.3.4 EUT Configurations In order to make the overall calculaton for each Configuration we have used the declared maximum power that will be produced by each combination of Bands and TX Antennas as supplied by Nokia and described in the following table. Configuration Number Configuration Name 1 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) 2 2 bands, 2 TX antenna connectors (B1/B3) 3 2 bands, 4 TX antenna connectors (B66/B25) 4 2 bands, 4 TX antenna connectors (B66a/B25) 5 2 bands, 4 TX antenna connectors (B5/B13) 6 2 bands, 4 TX antenna connectors (B1/B3) 7 2 bands, 4 TX antenna connectors (B12/B14) 8 2 bands, 4 TX antenna connectors (B12/B71) 9 2 bands, 4 TX antenna connectors (B5/B13) 10 2 bands, 8 TX antenna connectors (four connectors per band) (B2/B66a) 11 1 band, 4 TX antenna connectors (B28) 12 2 bands, 4TX antenna connectors (two dedicated connectors per band) (B29/B70) Detailed Description B28/B20/B8; Power Output: 2x2x60W (240W max); up to 2x120W if only one band in use; 2TX B20/B28+2TX B8 B3/B1; Power Output: 2x2x80W (240W max); 2TX B3+2TX B1 B66/B25: Power Output: 2x4x40W (320W max); 4TX B66+4TX B25 B66a/B25: Power Output: 2x4x40W (160W max); 4TX B66a+4TX B25 B5/B13: Power Output: 2x4x40W (320W max); 4TX B5+4TX B13 B3/B1: Power Output: 2x4x40W (320W max); 4TX B3+4TX B1 B12/B14: Power Output: 2x4x40W (320W max); 4TX B12+4TX B14 B71/B12: Power Output: 2x4x30W (240W max); 4TX B71+4TX B12 B5/B13: Power Output: 2x4x20W (160W max); 4TX B5+4TX B13 B66a/B2: Power Output: 4x60W B66a + 4x40W B2 (320W max) (SW limit 80W per B66a/B2 antenna pair); 4TX B66a+4TX B2 B28, Single Band: Power Output: 4x80W (320W max); 4TX B28 B29/B70: Power Output: 2x40W B29 + 2x60W B70 (RRH 200W max); 2TX B29+2TX B70 Document 75940792 Report 01 Issue 1 Page 7 of 30 1.4 BRIEF SUMMARY OF RESULTS The wireless device described within this report has been shown to be capable of compliance with the basic restrictions related to human exposure to electromagnetic fields for both General Public and Occupational. The calculations shown in this report were made in accordance with the procedures specified in the applied test specification(s). Configuration 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) 2 bands, 2 TX antenna connectors (B1/B3) 2 bands, 4 TX antenna connectors (B66/B25) 2 bands, 4 TX antenna connectors (B66a/B25) 2 bands, 4 TX antenna connectors (B5/B13) 2 bands, 4 TX antenna connectors (B1/B3) 2 bands, 4 TX antenna connectors (B12/B14) 2 bands, 4 TX antenna connectors (B12/B71) 2 bands, 4 TX antenna connectors (B5/B13) 2 bands, 8 TX antenna connectors (B2/B66a) 1 band, 4 TX antenna connectors (B28) 2 band, 4 TX antenna connectors (B29/B70) Required Compliance Boundary (m) Occupational General Population 6.85 18.51 5.52 13.76 6.26 15.54 4.43 10.99 7.94 21.49 6.37 15.89 7.99 21.66 7.52 19.85 5.62 15.20 6.26 15.53 7.91 21.37 6.37 17.22 Table 1 Compliance Boundary Results Document 75940792 Report 01 Issue 1 Page 8 of 30 1.4.1 Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) Regional Requirement Calculated RF exposure level at compliance boundary of 6.85 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 17.7586 18.9675 81.8220 82.6335 FCC* 1.7759 2.5290 N/A N/A IC 17.7586 17.7800 81.8220 81.8733 AUS 17.7586 18.9675 * Requirement and Result in mW/cm2 81.8220 84.5616 H Field (A/m) Result 0.2170 N/A 0.2170 0.2170 Limit 0.2204 N/A 0.2172 0.2242 Table 2 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.85 m. Regional Requirement Calculated RF exposure level at compliance boundary of 18.51 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.4321 3.7935 30.2799 37.8737 FCC* 0.2432 0.5058 N/A N/A IC 2.4321 2.4343 30.2799 30.2919 AUS 2.4321 3.7935 * Requirement and Result in mW/cm2 30.2799 37.7360 H Field (A/m) Result 0.0803 N/A 0.0803 0.0803 Limit 0.1019 N/A 0.0804 0.1003 Table 3 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 18.51 m. Document 75940792 Report 01 Issue 1 Page 9 of 30 1.4.2 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3) Regional Requirement Calculated RF exposure level at compliance boundary of 5.52 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 27.3471 45.1425 101.5363 127.4806 FCC* 2.7347 5.0000 N/A N/A IC 27.3471 27.4296 101.5363 101.6918 AUS 27.3471 45.1425 * Requirement and Result in mW/cm2 101.5363 130.4551 H Field (A/m) Result 0.2693 N/A 0.2693 0.2693 Limit 0.3399 N/A 0.2697 0.3459 Table 4 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 5.52 m. Regional Requirement Calculated RF exposure level at compliance boundary of 13.76 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 4.4010 9.0285 40.7326 58.4286 FCC* 0.4401 1.0000 N/A N/A IC 4.4010 4.4028 40.7326 40.7382 AUS 4.4010 9.0285 * Requirement and Result in mW/cm2 40.7326 58.2161 H Field (A/m) Result 0.1080 N/A 0.1080 0.1080 Limit 0.1572 N/A 0.1081 0.1547 Table 5 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 13.76 m. Document 75940792 Report 01 Issue 1 Page 10 of 30 1.4.3 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25) Regional Requirement Calculated RF exposure level at compliance boundary of 6.26 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 28.3558 48.2500 103.3918 131.7953 FCC* 2.8356 5.0000 N/A N/A IC 28.3558 28.3580 103.3918 103.3984 AUS 28.3558 48.2500 * Requirement and Result in mW/cm2 103.3918 134.8705 H Field (A/m) Result 0.2742 N/A 0.2742 0.2742 Limit 0.3515 N/A 0.2743 0.3576 Table 6 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.26 m. Regional Requirement Calculated RF exposure level at compliance boundary of 15.54 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 4.6014 9.6500 41.6495 60.4062 FCC* 0.4601 1.0000 N/A N/A IC 4.6014 4.6077 41.6495 41.6755 AUS 4.6014 9.6500 * Requirement and Result in mW/cm2 41.6495 60.1865 H Field (A/m) Result 0.1105 N/A 0.1105 0.1105 Limit 0.1625 N/A 0.1106 0.1599 Table 7 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.54 m. Document 75940792 Report 01 Issue 1 Page 11 of 30 1.4.4 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25) Regional Requirement Calculated RF exposure level at compliance boundary of 4.43 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 28.3128 48.2675 103.3135 131.8192 FCC* 2.8313 5.0000 N/A N/A IC 28.3128 28.3631 103.3135 103.4078 AUS 28.3128 48.2675 * Requirement and Result in mW/cm2 103.3135 134.8950 H Field (A/m) Result 0.2740 N/A 0.2740 0.2740 Limit 0.3515 N/A 0.2743 0.3577 Table 8 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 4.43 m. Regional Requirement Calculated RF exposure level at compliance boundary of 10.99 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 4.6004 9.6535 41.6450 60.4171 FCC* 0.4600 1.0000 N/A N/A IC 4.6004 4.6089 41.6450 41.6807 AUS 4.6004 9.6535 * Requirement and Result in mW/cm2 41.6450 60.1974 H Field (A/m) Result 0.1105 N/A 0.1105 0.1105 Limit 0.1626 N/A 0.1106 0.1599 Table 9 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 10.99 m. Document 75940792 Report 01 Issue 1 Page 12 of 30 1.4.5 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13) Regional Requirement Calculated RF exposure level at compliance boundary of 7.94 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 17.6258 18.6675 81.5155 81.9774 FCC* 1.7626 2.4890 N/A N/A IC 17.6258 17.6388 81.5155 81.5476 AUS 17.6258 18.6675 * Requirement and Result in mW/cm2 81.5155 83.8902 H Field (A/m) Result 0.2162 N/A 0.2162 0.2162 Limit 0.2186 N/A 0.2163 0.2224 Table 10 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.94 m. Regional Requirement Calculated RF exposure level at compliance boundary of 21.49 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.4061 3.7335 30.1179 37.5730 FCC* 0.2406 0.4978 N/A N/A IC 2.4061 2.4079 30.1179 30.1273 AUS 2.4061 3.7335 * Requirement and Result in mW/cm2 30.1179 37.4364 H Field (A/m) Result 0.0799 N/A 0.0799 0.0799 Limit 0.1011 N/A 0.0799 0.0995 Table 11 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 21.49 m. Document 75940792 Report 01 Issue 1 Page 13 of 30 1.4.6 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3) Regional Requirement Calculated RF exposure level at compliance boundary of 6.37 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 27.3849 45.1425 101.6064 127.4806 FCC* 2.7385 5.0000 N/A N/A IC 27.3849 27.4296 101.6064 101.6918 AUS 27.3849 45.1425 * Requirement and Result in mW/cm2 101.6064 130.4551 H Field (A/m) Result 0.2695 N/A 0.2695 0.2695 Limit 0.3399 N/A 0.2697 0.3459 Table 12 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.37 m. Regional Requirement Calculated RF exposure level at compliance boundary of 15.89 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 4.4009 9.0285 40.7321 58.4286 FCC* 0.4401 1.0000 N/A N/A IC 4.4009 4.4028 40.7321 40.7382 AUS 4.4009 9.0285 * Requirement and Result in mW/cm2 40.7321 58.2161 H Field (A/m) Result 0.1080 N/A 0.1080 0.1080 Limit 0.1572 N/A 0.1081 0.1547 Table 13 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.89 m. Document 75940792 Report 01 Issue 1 Page 14 of 30 1.4.7 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14) Regional Requirement Calculated RF exposure level at compliance boundary of 7.99 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 17.4059 18.2425 81.0053 81.0389 FCC* 1.7406 2.4323 N/A N/A IC 17.4059 17.4369 81.0053 81.0794 AUS 17.4059 18.2425 * Requirement and Result in mW/cm2 81.0053 82.9298 H Field (A/m) Result 0.2149 N/A 0.2149 0.2149 Limit 0.2161 N/A 0.2151 0.2199 Table 14 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.99 m. Regional Requirement Calculated RF exposure level at compliance boundary of 21.66 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.3685 3.6485 29.8815 37.1428 FCC* 0.2368 0.4865 N/A N/A IC 2.3685 2.3703 29.8815 29.8911 AUS 2.3685 3.6485 * Requirement and Result in mW/cm2 29.8815 37.0078 H Field (A/m) Result 0.0793 N/A 0.0793 0.0793 Limit 0.0999 N/A 0.0793 0.0983 Table 15 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 21.66 m. Document 75940792 Report 01 Issue 1 Page 15 of 30 1.4.8 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71) Regional Requirement Calculated RF exposure level at compliance boundary of 7.52 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 14.7351 15.4425 74.5320 74.5607 FCC* 1.4735 2.0590 N/A N/A IC 14.7351 16.0430 74.5320 77.7712 AUS 14.7351 15.4425 * Requirement and Result in mW/cm2 74.5320 76.3005 H Field (A/m) Result 0.1977 N/A 0.1977 0.1977 Limit 0.1988 N/A 0.2063 0.2023 Table 16 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.52 m. Regional Requirement Calculated RF exposure level at compliance boundary of 19.85 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.1148 3.0885 28.2358 34.1737 FCC* 0.2115 0.4118 N/A N/A IC 2.1148 2.1152 28.2358 28.2368 AUS 2.1148 3.0885 * Requirement and Result in mW/cm2 28.2358 34.0494 H Field (A/m) Result 0.0749 N/A 0.0749 0.0749 Limit 0.0920 N/A 0.0749 0.0905 Table 17 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 19.85 m. Document 75940792 Report 01 Issue 1 Page 16 of 30 1.4.9 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13) Regional Requirement Calculated RF exposure level at compliance boundary of 5.62 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 17.5921 18.6675 81.4375 81.9774 FCC* 1.7592 2.4890 N/A N/A IC 17.5921 17.6388 81.4375 81.5476 AUS 17.5921 18.6675 * Requirement and Result in mW/cm2 81.4375 83.8902 H Field (A/m) Result 0.2160 N/A 0.2160 0.2160 Limit 0.2186 N/A 0.2163 0.2224 Table 18 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 5.62 m. Regional Requirement Calculated RF exposure level at compliance boundary of 15.20 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.4049 3.7335 30.1104 37.5730 FCC* 0.2405 0.4978 N/A N/A IC 2.4049 2.4079 30.1104 30.1273 AUS 2.4049 3.7335 * Requirement and Result in mW/cm2 30.1104 37.4364 H Field (A/m) Result 0.0799 N/A 0.0799 0.0799 Limit 0.1011 N/A 0.0799 0.0995 Table 19 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.20 m. Document 75940792 Report 01 Issue 1 Page 17 of 30 1.4.10 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a) Regional Requirement Calculated RF exposure level at compliance boundary of 6.26 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 28.3558 48.2675 103.3918 131.8192 FCC* 2.8356 5.0000 N/A N/A IC 28.3558 28.3631 103.3918 103.4078 AUS 28.3558 48.2675 * Requirement and Result in mW/cm2 103.3918 134.8950 H Field (A/m) Result 0.2742 N/A 0.2742 0.2742 Limit 0.3515 N/A 0.2743 0.3577 Table 20 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.26 m. Regional Requirement Calculated RF exposure level at compliance boundary of 15.53 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 4.6073 9.6535 41.6763 60.4171 FCC* 0.4607 1.0000 N/A N/A IC 4.6073 4.6089 41.6763 41.6807 AUS 4.6073 9.6535 * Requirement and Result in mW/cm2 41.6763 60.1974 H Field (A/m) Result 0.1105 N/A 0.1105 0.1105 Limit 0.1626 N/A 0.1106 0.1599 Table 21 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.53 m. Document 75940792 Report 01 Issue 1 Page 18 of 30 1.4.11 Configuration 11 - 1 band, 4 TX antenna connectors (B28) Regional Requirement Calculated RF exposure level at compliance boundary of 7.91 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 17.7598 18.9675 81.8246 82.6335 FCC* 1.7760 2.5290 N/A N/A IC 17.7598 17.7800 81.8246 81.8733 AUS 17.7598 18.9675 * Requirement and Result in mW/cm2 81.8246 84.5616 H Field (A/m) Result 0.2170 N/A 0.2170 0.2170 Limit 0.2204 N/A 0.2172 0.2242 Table 22 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.91 m. Regional Requirement Calculated RF exposure level at compliance boundary of 21.37 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.4332 3.7935 30.2870 37.8737 FCC* 0.2433 0.5058 N/A N/A IC 2.4332 2.4343 30.2870 30.2919 AUS 2.4332 3.7935 * Requirement and Result in mW/cm2 30.2870 37.7360 H Field (A/m) Result 0.0803 N/A 0.0803 0.0803 Limit 0.1019 N/A 0.0804 0.1003 Table 23 General Population Results The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 21.37 m. Document 75940792 Report 01 Issue 1 Page 19 of 30 1.4.12 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70) Regional Requirement Calculated RF exposure level at compliance boundary of 6.37 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 17.1203 17.9425 80.3380 80.3698 FCC* 1.7120 2.3923 N/A N/A IC 17.1203 17.2929 80.3380 80.7440 AUS 17.1203 17.9425 * Requirement and Result in mW/cm2 80.3380 82.2451 H Field (A/m) Result 0.2131 N/A 0.2131 0.2131 Limit 0.2143 N/A 0.2142 0.2181 Table 24 Occupational Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.37 m. Regional Requirement Calculated RF exposure level at compliance boundary of 17.22 m S Field (W/m2) E Field (V/m) Result Limit Result Limit EU 2.3427 3.5885 29.7185 36.8361 FCC* 0.2343 0.4785 N/A N/A IC 2.3427 2.3436 29.7185 29.7223 AUS 2.3427 3.5885 * Requirement and Result in mW/cm2 29.7185 36.7022 H Field (A/m) Result 0.0788 N/A 0.0788 0.0788 Limit 0.0991 N/A 0.0788 0.0975 Table 25 General Population Results The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 17.22 m. Document 75940792 Report 01 Issue 1 Page 20 of 30 SECTION 2 TEST DETAILS Document 75940792 Report 01 Issue 1 Page 21 of 30 2.1 RATIONALE FOR ASSESSMENT OF THE RF EXPOSURE The aim of the assessment report is to evaluate the compliance boundary for a set of given input power(s) according to the basic restrictions (directly or indirectly via compliance with reference levels) related to human exposure to radio frequency electromagnetic fields. The chosen assessment method to establish the compliance boundary in the far-field region is the reference method as defined in the relevant specifications. The RF exposure assessment is based upon the following criteria: The AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) operates with the following transmitters active on the antenna ports shown in Section 1.3.3. For each transmitter, the Radio Access Technology (RAT), EIRP inclusive of antenna gain and duty cycle, gain of the antenna and lowest frequency of operation are shown as they contribute to the calculation of S Field, E field and H field values according to the following formulas. The power flux (S Field): S PG( , ) 4r 2 The electric field strength (E Field): E 30PG ( , ) r The magnetic field strength (H Field): HE o Where: P = Average Power (W) G = Antenna Gain (dBi) r = Distance (cm) or (m) o = 377 Document 75940792 Report 01 Issue 1 Page 22 of 30 2.2 2.2.1 TEST RESULT DETAILS The frequencies shown in the tables below have been chosen based on the lowest possible frequency that the EUT can transmit. Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (240W) EIRP (W) Duty Cycle (%) 10471.280 100 Gain (dBi) 16.4 Frequency (MHz) 758.7 RF Exposure Level at compliance boundary of 6.85 m S Field (W/m2) E Field (V/m) H Field (A/m) 17.7586 81.8220 0.2170 Table 26 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (240W) EIRP (W) Duty Cycle (%) 10471.280 100 Gain (dBi) 16.4 Frequency (MHz) 758.7 RF Exposure Level at compliance boundary of 18.51 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.4321 30.2799 0.0803 Table 27 General Population Transmitter Summary 2.2.2 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (240W) EIRP (W) Duty Cycle (%) 10471.280 100 Gain (dBi) 16.4 Frequency (MHz) 1805.7 RF Exposure Level at compliance boundary of 5.52 m S Field (W/m2) E Field (V/m) H Field (A/m) 27.3471 101.5363 0.2693 Table 28 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (240W) EIRP (W) Duty Cycle (%) 10471.280 100 Gain (dBi) 16.4 Frequency (MHz) 1805.7 RF Exposure Level at compliance boundary of 13.76 m S Field (W/m2) E Field (V/m) H Field (A/m) 4.4010 40.7326 0.1080 Table 29 General Population Transmitter Summary Document 75940792 Report 01 Issue 1 Page 23 of 30 2.2.3 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 1930.7 RF Exposure Level at compliance boundary of 6.26 m S Field (W/m2) E Field (V/m) H Field (A/m) 28.3558 103.3918 0.2742 Table 30 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 1930.7 RF Exposure Level at compliance boundary of 15.54 m S Field (W/m2) E Field (V/m) H Field (A/m) 4.6014 41.6495 0.1105 Table 31 General Population Transmitter Summary 2.2.4 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (160W) EIRP (W) Duty Cycle (%) 6982.328 100 Gain (dBi) 16.4 Frequency (MHz) 1930.7 RF Exposure Level at compliance boundary of 4.43 m S Field (W/m2) E Field (V/m) H Field (A/m) 28.3128 103.3135 0.2740 Table 32 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (160W) EIRP (W) Duty Cycle (%) 6982.328 100 Gain (dBi) 16.4 Frequency (MHz) 1930.7 RF Exposure Level at compliance boundary of 10.99 m S Field (W/m2) E Field (V/m) H Field (A/m) 4.6004 41.6450 0.1105 Table 33 General Population Transmitter Summary Document 75940792 Report 01 Issue 1 Page 24 of 30 2.2.5 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 746.7 RF Exposure Level at compliance boundary of 7.94 m S Field (W/m2) E Field (V/m) H Field (A/m) 17.6258 81.5155 0.2162 Table 34 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 746.7 RF Exposure Level at compliance boundary of 21.49 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.4061 30.1179 0.0799 Table 35 General Population Transmitter Summary 2.2.6 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 1805.7 RF Exposure Level at compliance boundary of 6.37 m S Field (W/m2) E Field (V/m) H Field (A/m) 27.3849 101.6064 0.2695 Table 36 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 1805.7 RF Exposure Level at compliance boundary of 15.89 m S Field (W/m2) E Field (V/m) H Field (A/m) 4.4009 40.7321 0.1080 Table 37 General Population Transmitter Summary Document 75940792 Report 01 Issue 1 Page 25 of 30 2.2.7 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 729.7 RF Exposure Level at compliance boundary of 7.99 m S Field (W/m2) E Field (V/m) H Field (A/m) 17.4059 81.0053 0.2149 Table 38 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 729.7 RF Exposure Level at compliance boundary of 21.66 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.3685 29.8815 0.0793 Table 39 General Population Transmitter Summary 2.2.8 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (240W) EIRP (W) Duty Cycle (%) 10471.280 100 Gain (dBi) 16.4 Frequency (MHz) 617.7 RF Exposure Level at compliance boundary of 7.52 m S Field (W/m2) E Field (V/m) H Field (A/m) 14.7351 74.5320 0.1977 Table 40 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (240W) EIRP (W) Duty Cycle (%) 10471.280 100 Gain (dBi) 16.4 Frequency (MHz) 617.7 RF Exposure Level at compliance boundary of 19.85 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.1148 28.2358 0.0749 Table 41 General Population Transmitter Summary Document 75940792 Report 01 Issue 1 Page 26 of 30 2.2.9 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (160W) EIRP (W) Duty Cycle (%) 6982.328 100 Gain (dBi) 16.4 Frequency (MHz) 746.7 RF Exposure Level at compliance boundary of 5.62 m S Field (W/m2) E Field (V/m) H Field (A/m) 17.5921 81.4375 0.2160 Table 42 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (160W) EIRP (W) Duty Cycle (%) 6982.328 100 Gain (dBi) 16.4 Frequency (MHz) 746.7 RF Exposure Level at compliance boundary of 15.20 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.4049 30.1104 0.0799 Table 43 General Population Transmitter Summary 2.2.10 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 1930.7 RF Exposure Level at compliance boundary of 6.26 m S Field (W/m2) E Field (V/m) H Field (A/m) 28.3558 103.3918 0.2742 Table 44 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 1930.7 RF Exposure Level at compliance boundary of 15.53 m S Field (W/m2) E Field (V/m) H Field (A/m) 4.6073 41.6763 0.1105 Table 45 General Population Transmitter Summary Document 75940792 Report 01 Issue 1 Page 27 of 30 2.2.11 Configuration 11 - 1 band, 4 TX antenna connectors (B28) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 758.7 RF Exposure Level at compliance boundary of 7.91 m S Field (W/m2) E Field (V/m) H Field (A/m) 17.7598 81.8246 0.2170 Table 46 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (320W) EIRP (W) Duty Cycle (%) 13963.670 100 Gain (dBi) 16.4 Frequency (MHz) 758.7 RF Exposure Level at compliance boundary of 21.37 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.4332 30.2870 0.0803 Table 47 General Population Transmitter Summary 2.2.12 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70) Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (200W) EIRP (W) Duty Cycle (%) 8729.706 100 Gain (dBi) 16.4 Frequency (MHz) 717.7 RF Exposure Level at compliance boundary of 6.37 m S Field (W/m2) E Field (V/m) H Field (A/m) 17.1203 80.3380 0.2131 Table 48 Occupational Transmitter Summary Antenna Port Tx No. Ant No. RAT 1 1 1 LTE (200W) EIRP (W) Duty Cycle (%) 8729.706 100 Gain (dBi) 16.4 Frequency (MHz) 717.7 RF Exposure Level at compliance boundary of 17.22 m S Field (W/m2) E Field (V/m) H Field (A/m) 2.3427 29.7185 0.0788 Table 49 General Population Transmitter Summary Document 75940792 Report 01 Issue 1 Page 28 of 30 SECTION 3 DISCLAIMERS AND COPYRIGHT Document 75940792 Report 01 Issue 1 Page 29 of 30 3.1 DISCLAIMERS AND COPYRIGHT This report relates only to the actual item/items tested. This report must not be reproduced, except in its entirety, without the written permission of TÜV SÜD Product Service © 2017 TÜV SÜD Product Service Document 75940792 Report 01 Issue 1 Page 30 of 30 ANNEX A REGIONAL REQUIREMENTS Document 75940792 Report 01 Issue 1 Page A.1 of A.3 Frequency Range (MHz) 0.065 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000 Frequency Range (MHz) 0.003 - 0.15 0.15 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000 Frequency Range (MHz) 0 - 0.3 0.3 - 3 3 - 30 30 - 300 300 - 1500 1500 - 100000 Frequency Range (MHz) 0 - 0.3 0.3 - 3 3 - 30 30 - 300 300 - 1500 1500 - 100000 Power Density (W/m2) 10 f/40 50 Electric Field Strength (V/m) 610 610/f 61 3*f^0.5 137 Magnetic Field Strength (A/m) 1.6/f 1.6/f 0.162 0.008*f^0.5 0.36 Table A.1 EN 62311:2008 Occupational Limits Power Density (W/m2) 2 f/200 10 Electric Field Strength (V/m) 87 87 87/f^0.5 28 1.375*f^0.5 61 Magnetic Field Strength (A/m) 5 0.73/f 0.73/f 0.073 0.0037*f^0.5 0.16 Table A.2 EN 62311:2008 General Population Limits Power Density (mW/cm2) 100 900/f^2 1 f/300 5 Electric Field Strength (V/m) 614 1842/f 61.4 - Magnetic Field Strength (A/m) 1.63 4.89/f 0.163 - Table A.3 CFR 47 Pt1.1310 (2016) Occupational Limits Power Density (mW/cm2) 100 180/f^2 0.2 f/1500 1 Electric Field Strength (V/m) 614 824/f 27.5 - Magnetic Field Strength (A/m) 1.63 2.19/f 0.073 - Table A.4 CFR 47 Pt1.1310 (2016) General Population Limits Document 75940792 Report 01 Issue 1 Page A.2 of A.3 Frequency Range (MHz) 10 - 20 20 - 48 48 - 100 100 - 6000 6000 - 150000 Power Density (W/m2) 10 44.72/f^0.5 6.455 0.6455*f^0.5 50 Electric Field Strength (V/m) 61.4 129.8/f^0.25 49.33 15.60*f^0.25 137 Magnetic Field Strength (A/m) 0.163 0.3444/f^0.25 0.1309 0.04138*f^0.25 0.364 Table A.5 Health Canada Safety Code 6 Occupational Limits Frequency Range (MHz) 10 - 20 20 - 48 48 - 300 300 - 6000 6000 - 15000 Power Density (W/m2) 2 8.944/f^0.5 1.291 0.02619*f^0.6834 10 Electric Field Strength (V/m) 27.46 58.07/f^0.25 22.06 3.142*f^0.3417 61.4 Magnetic Field Strength (A/m) 0.0728 0.1540/f^0.25 0.05852 0.008335*f^0.3417 0.163 Table A.6 Health Canada Safety Code 6 General Population Limits Frequency Range (MHz) 0.1 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000 Power Density (W/m2) 1000/f^2 10 f/40 50 Electric Field Strength (V/m) 614 614 61.4 3.07*f^0.5 137 Magnetic Field Strength (A/m) 1.63/f 1.63/f 0.163 0.00814*f^0.5 0.364 Table A.7 ARPANSA Radiation Protection Series No.3 Occupational Limits Frequency Range (MHz) 0.1 - 0.15 0.15 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000 Power Density (W/m2) 2 f/200 10 Electric Field Strength (V/m) 86.8 86.8 86.8/f^0.5 27.4 1.37*f^0.5 61.4 Magnetic Field Strength (A/m) 4.86 0.729/f 0.729/f 0.0729 0.00364*f^0.5 0.163 Table A.8 ARPANSA Radiation Protection Series No.3 General Population Limits Document 75940792 Report 01 Issue 1 Page A.3 of A.3
Related FCC IDs:
- VBNAHFIB-01 - Nokia Solutions and Networks Remote Radio Head [AHFIB-01] Acrobat Distiller 18.0 (Windows)