75940792 Report 01 Issue 01 Draft 3

baile-na

RF Exposure info

Nokia Solutions and Networks AHFIB-01 Remote Radio Head VBNAHFIB-01 VBNAHFIB01 ahfib 01

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 34 Pages, 259.99KB

Document DEVICE REPORTGetApplicationAttachment.html?id=4176798
Report On
RF Exposure Assessment of the Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71)

Document 75940792 Report 01 Issue 1

December 2017

TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North, Fareham, Hampshire, United Kingdom, PO15 5RL
Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk

REPORT ON
PREPARED FOR PREPARED BY APPROVED BY DATED

RF Exposure Assessment of the Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) Document 75940792 Report 01 Issue 1 December 2017
Nokia Solutions and Networks Oy Kaapelitie 4 Oulu Finland
Maggie Whiting Project Manager
Matthew Russell Authorised Signatory
12 December 2017

Document 75940792 Report 01 Issue 1

Page 1 of 30

Section

CONTENTS

Page No

1
1.1 1.2 1.3 1.3.1 1.3.2 1.3.3 1.3.4 1.4 1.4.1 1.4.2 1.4.3 1.4.4 1.4.5 1.4.6 1.4.7 1.4.8 1.4.9 1.4.10 1.4.11 1.4.12
2
2.1 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.2.7 2.2.8 2.2.9 2.2.10 2.2.11 2.2.12
3
3.1

REPORT SUMMARY ................................................................................................................... 3
Introduction .................................................................................................................................... 4 Regional Requirements ................................................................................................................. 5 Product Information ....................................................................................................................... 6 Technical Description .................................................................................................................... 6 Supported Features ....................................................................................................................... 6 Antennas........................................................................................................................................ 6 EUT Configurations ....................................................................................................................... 7 Brief Summary of Results .............................................................................................................. 8 Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) ............................................ 9 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3)..................................................... 10 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25) ................................................ 11 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25) .............................................. 12 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 13 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3)..................................................... 14 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14) ................................................ 15 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71) ................................................ 16 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 17 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a) .............................................. 18 Configuration 11 - 1 band, 4 TX antenna connectors (B28)........................................................ 19 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70) ................................................ 20
TEST DETAILS .......................................................................................................................... 21
Rationale for Assessment of the RF Exposure ........................................................................... 22 Test Result Details....................................................................................................................... 23 Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28) .......................................... 23 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3)..................................................... 23 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25) ................................................ 24 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25) .............................................. 24 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 25 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3)..................................................... 25 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14) ................................................ 26 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71) ................................................ 26 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13)................................................... 27 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a) .............................................. 27 Configuration 11 - 1 band, 4 TX antenna connectors (B28)........................................................ 28 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70) ................................................ 28
DISCLAIMERS AND COPYRIGHT............................................................................................ 29
Disclaimers and Copyright........................................................................................................... 30

Document 75940792 Report 01 Issue 1

Page 2 of 30

SECTION 1
REPORT SUMMARY
RF Exposure Assessment of the Nokia Solutions and Networks AirScale Base Station Products
and Flexi Multiradio Station Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71)

Document 75940792 Report 01 Issue 1

Page 3 of 30

1.1

INTRODUCTION

The information contained in this report is intended to show verification of the RF Exposure Assessment of the Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) to the requirements of the applied test specifications.

Objective
Applicant Manufacturer Manufacturing Description
Model Number(s) Test Specification/Issue/Date
Related Documents

To perform RF Exposure Assessment to determine the Equipment Under Test's (EUT's) compliance of the applied rules.
Nokia Solutions and Networks
Nokia Solutions and Networks Oy
AirScale Base Station Products and Flexi Multiradio Base Station Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71)
AirScale and Flexi Multiradio Base Station Multiband Products EN 62311:2008 CFR 47 Pt1.1310 (2016) Health Canada Safety Code 6 ARPANSA Radiation Protection Series No.3 EN 50385: 2017

Document 75940792 Report 01 Issue 1

Page 4 of 30

1.2

REGIONAL REQUIREMENTS

The table below shows the regional requirements that are referenced in this test report. A full list of the requirements is shown in Annex A.

Report Reference EU FCC IC AUS

Regional Requirement EN 62311:2008 CFR 47 Pt1.1310 (2016) Health Canada Safety Code 6 ARPANSA Radiation Protection Series No.3

Document 75940792 Report 01 Issue 1

Page 5 of 30

1.3

PRODUCT INFORMATION

1.3.1

Technical Description
The Equipment under test was a Nokia Solutions and Networks AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71). A full technical description can be found in the manufacturer's documentation.
All reported calculations were carried out on the relevant information supplied for the AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) to demonstrate compliance with the applied test specification(s). The sample assessed was found to comply with the requirements of the applied rules.

1.3.2

Supported Features
The following radio access technologies and frequency bands are supported by the equipment under test.

Radio Access Technology

LTE (120W) LTE (160W) LTE (200W) LTE (240W) LTE (320W)

Frequency Band

Band 8 + Band 20 + Band 28 (758-960) Band 1 + Band 3 (1805-2170) Band 66 + Band 25 (1930-2200) Band 66a + Band 25 (1930-2180) Band 5 + Band 13 (746-894) Band 12 + Band 14 (729-768) Band 12 + Band 71 (617-746) Band 2 + Band 66a (1930-2180) Band 28 (758-803) Band 66a (2110-2180) Band 1+ Band 3 (1805-2170) Band 28+Band 20 (758-821) Band 29 + Band 70 (717-2020)

1.3.3

Antennas The following antennas are supported by the equipment under test.

No.

Model

Gain(dB)

1

Not Supplied

16.4

Document 75940792 Report 01 Issue 1

Page 6 of 30

1.3.4

EUT Configurations
In order to make the overall calculaton for each Configuration we have used the declared maximum power that will be produced by each combination of Bands and TX Antennas as supplied by Nokia and described in the following table.

Configuration Number

Configuration Name

1

3 bands, 4 Tx Antenna Connectors (B8/B20/B28)

2

2 bands, 2 TX antenna connectors (B1/B3)

3

2 bands, 4 TX antenna connectors (B66/B25)

4

2 bands, 4 TX antenna connectors (B66a/B25)

5

2 bands, 4 TX antenna connectors (B5/B13)

6

2 bands, 4 TX antenna connectors (B1/B3)

7

2 bands, 4 TX antenna connectors (B12/B14)

8

2 bands, 4 TX antenna connectors (B12/B71)

9

2 bands, 4 TX antenna connectors (B5/B13)

10

2 bands, 8 TX antenna connectors (four connectors per band) (B2/B66a)

11

1 band, 4 TX antenna connectors (B28)

12

2 bands, 4TX antenna connectors (two dedicated connectors per band) (B29/B70)

Detailed Description
B28/B20/B8; Power Output: 2x2x60W (240W max); up to 2x120W if only one band in use; 2TX B20/B28+2TX B8 B3/B1; Power Output: 2x2x80W (240W max); 2TX B3+2TX B1 B66/B25: Power Output: 2x4x40W (320W max); 4TX B66+4TX B25 B66a/B25: Power Output: 2x4x40W (160W max); 4TX B66a+4TX B25 B5/B13: Power Output: 2x4x40W (320W max); 4TX B5+4TX B13 B3/B1: Power Output: 2x4x40W (320W max); 4TX B3+4TX B1 B12/B14: Power Output: 2x4x40W (320W max); 4TX B12+4TX B14 B71/B12: Power Output: 2x4x30W (240W max); 4TX B71+4TX B12 B5/B13: Power Output: 2x4x20W (160W max); 4TX B5+4TX B13 B66a/B2: Power Output: 4x60W B66a + 4x40W B2 (320W max) (SW limit 80W per B66a/B2 antenna pair); 4TX B66a+4TX B2 B28, Single Band: Power Output: 4x80W (320W max); 4TX B28
B29/B70: Power Output: 2x40W B29 + 2x60W B70 (RRH 200W max); 2TX B29+2TX B70

Document 75940792 Report 01 Issue 1

Page 7 of 30

1.4

BRIEF SUMMARY OF RESULTS

The wireless device described within this report has been shown to be capable of compliance with the basic restrictions related to human exposure to electromagnetic fields for both General Public and Occupational. The calculations shown in this report were made in accordance with the procedures specified in the applied test specification(s).

Configuration
3 bands, 4 Tx Antenna Connectors (B8/B20/B28) 2 bands, 2 TX antenna connectors (B1/B3) 2 bands, 4 TX antenna connectors (B66/B25) 2 bands, 4 TX antenna connectors (B66a/B25) 2 bands, 4 TX antenna connectors (B5/B13) 2 bands, 4 TX antenna connectors (B1/B3) 2 bands, 4 TX antenna connectors (B12/B14) 2 bands, 4 TX antenna connectors (B12/B71) 2 bands, 4 TX antenna connectors (B5/B13) 2 bands, 8 TX antenna connectors (B2/B66a) 1 band, 4 TX antenna connectors (B28) 2 band, 4 TX antenna connectors (B29/B70)

Required Compliance Boundary (m)

Occupational

General Population

6.85

18.51

5.52

13.76

6.26

15.54

4.43

10.99

7.94

21.49

6.37

15.89

7.99

21.66

7.52

19.85

5.62

15.20

6.26

15.53

7.91

21.37

6.37

17.22

Table 1 ­ Compliance Boundary Results

Document 75940792 Report 01 Issue 1

Page 8 of 30

1.4.1 Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28)

Regional Requirement

Calculated RF exposure level at compliance boundary of 6.85 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

17.7586

18.9675

81.8220

82.6335

FCC*

1.7759

2.5290

N/A

N/A

IC

17.7586

17.7800

81.8220

81.8733

AUS

17.7586

18.9675

* Requirement and Result in mW/cm2

81.8220

84.5616

H Field (A/m) Result 0.2170 N/A 0.2170 0.2170

Limit 0.2204 N/A 0.2172 0.2242

Table 2 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.85 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 18.51 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.4321

3.7935

30.2799

37.8737

FCC*

0.2432

0.5058

N/A

N/A

IC

2.4321

2.4343

30.2799

30.2919

AUS

2.4321

3.7935

* Requirement and Result in mW/cm2

30.2799

37.7360

H Field (A/m) Result 0.0803 N/A 0.0803 0.0803

Limit 0.1019 N/A 0.0804 0.1003

Table 3 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 18.51 m.

Document 75940792 Report 01 Issue 1

Page 9 of 30

1.4.2 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3)

Regional Requirement

Calculated RF exposure level at compliance boundary of 5.52 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

27.3471

45.1425

101.5363

127.4806

FCC*

2.7347

5.0000

N/A

N/A

IC

27.3471

27.4296

101.5363

101.6918

AUS

27.3471

45.1425

* Requirement and Result in mW/cm2

101.5363

130.4551

H Field (A/m) Result 0.2693 N/A 0.2693 0.2693

Limit 0.3399 N/A 0.2697 0.3459

Table 4 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 5.52 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 13.76 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

4.4010

9.0285

40.7326

58.4286

FCC*

0.4401

1.0000

N/A

N/A

IC

4.4010

4.4028

40.7326

40.7382

AUS

4.4010

9.0285

* Requirement and Result in mW/cm2

40.7326

58.2161

H Field (A/m) Result 0.1080 N/A 0.1080 0.1080

Limit 0.1572 N/A 0.1081 0.1547

Table 5 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 13.76 m.

Document 75940792 Report 01 Issue 1

Page 10 of 30

1.4.3 Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25)

Regional Requirement

Calculated RF exposure level at compliance boundary of 6.26 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

28.3558

48.2500

103.3918

131.7953

FCC*

2.8356

5.0000

N/A

N/A

IC

28.3558

28.3580

103.3918

103.3984

AUS

28.3558

48.2500

* Requirement and Result in mW/cm2

103.3918

134.8705

H Field (A/m) Result 0.2742 N/A 0.2742 0.2742

Limit 0.3515 N/A 0.2743 0.3576

Table 6 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.26 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 15.54 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

4.6014

9.6500

41.6495

60.4062

FCC*

0.4601

1.0000

N/A

N/A

IC

4.6014

4.6077

41.6495

41.6755

AUS

4.6014

9.6500

* Requirement and Result in mW/cm2

41.6495

60.1865

H Field (A/m) Result 0.1105 N/A 0.1105 0.1105

Limit 0.1625 N/A 0.1106 0.1599

Table 7 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.54 m.

Document 75940792 Report 01 Issue 1

Page 11 of 30

1.4.4 Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25)

Regional Requirement

Calculated RF exposure level at compliance boundary of 4.43 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

28.3128

48.2675

103.3135

131.8192

FCC*

2.8313

5.0000

N/A

N/A

IC

28.3128

28.3631

103.3135

103.4078

AUS

28.3128

48.2675

* Requirement and Result in mW/cm2

103.3135

134.8950

H Field (A/m) Result 0.2740 N/A 0.2740 0.2740

Limit 0.3515 N/A 0.2743 0.3577

Table 8 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 4.43 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 10.99 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

4.6004

9.6535

41.6450

60.4171

FCC*

0.4600

1.0000

N/A

N/A

IC

4.6004

4.6089

41.6450

41.6807

AUS

4.6004

9.6535

* Requirement and Result in mW/cm2

41.6450

60.1974

H Field (A/m) Result 0.1105 N/A 0.1105 0.1105

Limit 0.1626 N/A 0.1106 0.1599

Table 9 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 10.99 m.

Document 75940792 Report 01 Issue 1

Page 12 of 30

1.4.5 Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13)

Regional Requirement

Calculated RF exposure level at compliance boundary of 7.94 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

17.6258

18.6675

81.5155

81.9774

FCC*

1.7626

2.4890

N/A

N/A

IC

17.6258

17.6388

81.5155

81.5476

AUS

17.6258

18.6675

* Requirement and Result in mW/cm2

81.5155

83.8902

H Field (A/m) Result 0.2162 N/A 0.2162 0.2162

Limit 0.2186 N/A 0.2163 0.2224

Table 10 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.94 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 21.49 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.4061

3.7335

30.1179

37.5730

FCC*

0.2406

0.4978

N/A

N/A

IC

2.4061

2.4079

30.1179

30.1273

AUS

2.4061

3.7335

* Requirement and Result in mW/cm2

30.1179

37.4364

H Field (A/m) Result 0.0799 N/A 0.0799 0.0799

Limit 0.1011 N/A 0.0799 0.0995

Table 11 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 21.49 m.

Document 75940792 Report 01 Issue 1

Page 13 of 30

1.4.6 Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3)

Regional Requirement

Calculated RF exposure level at compliance boundary of 6.37 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

27.3849

45.1425

101.6064

127.4806

FCC*

2.7385

5.0000

N/A

N/A

IC

27.3849

27.4296

101.6064

101.6918

AUS

27.3849

45.1425

* Requirement and Result in mW/cm2

101.6064

130.4551

H Field (A/m) Result 0.2695 N/A 0.2695 0.2695

Limit 0.3399 N/A 0.2697 0.3459

Table 12 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.37 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 15.89 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

4.4009

9.0285

40.7321

58.4286

FCC*

0.4401

1.0000

N/A

N/A

IC

4.4009

4.4028

40.7321

40.7382

AUS

4.4009

9.0285

* Requirement and Result in mW/cm2

40.7321

58.2161

H Field (A/m) Result 0.1080 N/A 0.1080 0.1080

Limit 0.1572 N/A 0.1081 0.1547

Table 13 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.89 m.

Document 75940792 Report 01 Issue 1

Page 14 of 30

1.4.7 Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14)

Regional Requirement

Calculated RF exposure level at compliance boundary of 7.99 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

17.4059

18.2425

81.0053

81.0389

FCC*

1.7406

2.4323

N/A

N/A

IC

17.4059

17.4369

81.0053

81.0794

AUS

17.4059

18.2425

* Requirement and Result in mW/cm2

81.0053

82.9298

H Field (A/m) Result 0.2149 N/A 0.2149 0.2149

Limit 0.2161 N/A 0.2151 0.2199

Table 14 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.99 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 21.66 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.3685

3.6485

29.8815

37.1428

FCC*

0.2368

0.4865

N/A

N/A

IC

2.3685

2.3703

29.8815

29.8911

AUS

2.3685

3.6485

* Requirement and Result in mW/cm2

29.8815

37.0078

H Field (A/m) Result 0.0793 N/A 0.0793 0.0793

Limit 0.0999 N/A 0.0793 0.0983

Table 15 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 21.66 m.

Document 75940792 Report 01 Issue 1

Page 15 of 30

1.4.8 Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71)

Regional Requirement

Calculated RF exposure level at compliance boundary of 7.52 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

14.7351

15.4425

74.5320

74.5607

FCC*

1.4735

2.0590

N/A

N/A

IC

14.7351

16.0430

74.5320

77.7712

AUS

14.7351

15.4425

* Requirement and Result in mW/cm2

74.5320

76.3005

H Field (A/m) Result 0.1977 N/A 0.1977 0.1977

Limit 0.1988 N/A 0.2063 0.2023

Table 16 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.52 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 19.85 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.1148

3.0885

28.2358

34.1737

FCC*

0.2115

0.4118

N/A

N/A

IC

2.1148

2.1152

28.2358

28.2368

AUS

2.1148

3.0885

* Requirement and Result in mW/cm2

28.2358

34.0494

H Field (A/m) Result 0.0749 N/A 0.0749 0.0749

Limit 0.0920 N/A 0.0749 0.0905

Table 17 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 19.85 m.

Document 75940792 Report 01 Issue 1

Page 16 of 30

1.4.9 Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13)

Regional Requirement

Calculated RF exposure level at compliance boundary of 5.62 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

17.5921

18.6675

81.4375

81.9774

FCC*

1.7592

2.4890

N/A

N/A

IC

17.5921

17.6388

81.4375

81.5476

AUS

17.5921

18.6675

* Requirement and Result in mW/cm2

81.4375

83.8902

H Field (A/m) Result 0.2160 N/A 0.2160 0.2160

Limit 0.2186 N/A 0.2163 0.2224

Table 18 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 5.62 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 15.20 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.4049

3.7335

30.1104

37.5730

FCC*

0.2405

0.4978

N/A

N/A

IC

2.4049

2.4079

30.1104

30.1273

AUS

2.4049

3.7335

* Requirement and Result in mW/cm2

30.1104

37.4364

H Field (A/m) Result 0.0799 N/A 0.0799 0.0799

Limit 0.1011 N/A 0.0799 0.0995

Table 19 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.20 m.

Document 75940792 Report 01 Issue 1

Page 17 of 30

1.4.10 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a)

Regional Requirement

Calculated RF exposure level at compliance boundary of 6.26 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

28.3558

48.2675

103.3918

131.8192

FCC*

2.8356

5.0000

N/A

N/A

IC

28.3558

28.3631

103.3918

103.4078

AUS

28.3558

48.2675

* Requirement and Result in mW/cm2

103.3918

134.8950

H Field (A/m) Result 0.2742 N/A 0.2742 0.2742

Limit 0.3515 N/A 0.2743 0.3577

Table 20 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.26 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 15.53 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

4.6073

9.6535

41.6763

60.4171

FCC*

0.4607

1.0000

N/A

N/A

IC

4.6073

4.6089

41.6763

41.6807

AUS

4.6073

9.6535

* Requirement and Result in mW/cm2

41.6763

60.1974

H Field (A/m) Result 0.1105 N/A 0.1105 0.1105

Limit 0.1626 N/A 0.1106 0.1599

Table 21 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 15.53 m.

Document 75940792 Report 01 Issue 1

Page 18 of 30

1.4.11 Configuration 11 - 1 band, 4 TX antenna connectors (B28)

Regional Requirement

Calculated RF exposure level at compliance boundary of 7.91 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

17.7598

18.9675

81.8246

82.6335

FCC*

1.7760

2.5290

N/A

N/A

IC

17.7598

17.7800

81.8246

81.8733

AUS

17.7598

18.9675

* Requirement and Result in mW/cm2

81.8246

84.5616

H Field (A/m) Result 0.2170 N/A 0.2170 0.2170

Limit 0.2204 N/A 0.2172 0.2242

Table 22 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 7.91 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 21.37 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.4332

3.7935

30.2870

37.8737

FCC*

0.2433

0.5058

N/A

N/A

IC

2.4332

2.4343

30.2870

30.2919

AUS

2.4332

3.7935

* Requirement and Result in mW/cm2

30.2870

37.7360

H Field (A/m) Result 0.0803 N/A 0.0803 0.0803

Limit 0.1019 N/A 0.0804 0.1003

Table 23 ­ General Population Results

The calculations show that the EUT complies with the general population exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 21.37 m.

Document 75940792 Report 01 Issue 1

Page 19 of 30

1.4.12 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70)

Regional Requirement

Calculated RF exposure level at compliance boundary of 6.37 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

17.1203

17.9425

80.3380

80.3698

FCC*

1.7120

2.3923

N/A

N/A

IC

17.1203

17.2929

80.3380

80.7440

AUS

17.1203

17.9425

* Requirement and Result in mW/cm2

80.3380

82.2451

H Field (A/m) Result 0.2131 N/A 0.2131 0.2131

Limit 0.2143 N/A 0.2142 0.2181

Table 24 ­ Occupational Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 6.37 m.

Regional Requirement

Calculated RF exposure level at compliance boundary of 17.22 m

S Field (W/m2)

E Field (V/m)

Result

Limit

Result

Limit

EU

2.3427

3.5885

29.7185

36.8361

FCC*

0.2343

0.4785

N/A

N/A

IC

2.3427

2.3436

29.7185

29.7223

AUS

2.3427

3.5885

* Requirement and Result in mW/cm2

29.7185

36.7022

H Field (A/m) Result 0.0788 N/A 0.0788 0.0788

Limit 0.0991 N/A 0.0788 0.0975

Table 25 ­ General Population Results

The calculations show that the EUT complies with the occupational exposure levels described in the EN 62311:2008, CFR 47 Pt1.1310 (2016), Health Canada Safety Code 6 and ARPANSA Radiation Protection Series No.3 at the point of investigation, 17.22 m.

Document 75940792 Report 01 Issue 1

Page 20 of 30

SECTION 2 TEST DETAILS

Document 75940792 Report 01 Issue 1

Page 21 of 30

2.1

RATIONALE FOR ASSESSMENT OF THE RF EXPOSURE

The aim of the assessment report is to evaluate the compliance boundary for a set of given input power(s) according to the basic restrictions (directly or indirectly via compliance with reference levels) related to human exposure to radio frequency electromagnetic fields. The chosen assessment method to establish the compliance boundary in the far-field region is the reference method as defined in the relevant specifications.
The RF exposure assessment is based upon the following criteria:
The AirScale and Flexi Multiradio Base Station Multiband Products (Bands 1, 2, 3, 5, 8, 12, 13, 14, 20, 25, 28, 29, 66, 66a, 70 and 71) operates with the following transmitters active on the antenna ports shown in Section 1.3.3. For each transmitter, the Radio Access Technology (RAT), EIRP inclusive of antenna gain and duty cycle, gain of the antenna and lowest frequency of operation are shown as they contribute to the calculation of S Field, E field and H field values according to the following formulas.
The power flux (S Field):

S



PG( , ) 4r 2

The electric field strength (E Field):

E  30PG ( ,  ) r
The magnetic field strength (H Field):

HE o
Where:
P = Average Power (W) G = Antenna Gain (dBi) r = Distance (cm) or (m)
o = 377

Document 75940792 Report 01 Issue 1

Page 22 of 30

2.2 2.2.1

TEST RESULT DETAILS
The frequencies shown in the tables below have been chosen based on the lowest possible frequency that the EUT can transmit.
Configuration 1 - 3 bands, 4 Tx Antenna Connectors (B8/B20/B28)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (240W)

EIRP (W)

Duty Cycle (%)

10471.280 100

Gain (dBi)
16.4

Frequency (MHz)
758.7

RF Exposure Level at compliance boundary of 6.85 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

17.7586 81.8220 0.2170

Table 26 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (240W)

EIRP (W)

Duty Cycle (%)

10471.280 100

Gain (dBi)
16.4

Frequency (MHz)
758.7

RF Exposure Level at compliance boundary of 18.51 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.4321 30.2799 0.0803

Table 27 ­ General Population Transmitter Summary

2.2.2 Configuration 2 - 2 bands, 2 TX antenna connectors (B1/B3)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (240W)

EIRP (W)

Duty Cycle (%)

10471.280 100

Gain (dBi)
16.4

Frequency (MHz)
1805.7

RF Exposure Level at compliance boundary of 5.52 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

27.3471 101.5363 0.2693

Table 28 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (240W)

EIRP (W)

Duty Cycle (%)

10471.280 100

Gain (dBi)
16.4

Frequency (MHz)
1805.7

RF Exposure Level at compliance boundary of 13.76 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

4.4010 40.7326 0.1080

Table 29 ­ General Population Transmitter Summary

Document 75940792 Report 01 Issue 1

Page 23 of 30

2.2.3

Configuration 3 - 2 bands, 4 TX antenna connectors (B66/B25)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
1930.7

RF Exposure Level at compliance boundary of 6.26 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

28.3558 103.3918 0.2742

Table 30 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
1930.7

RF Exposure Level at compliance boundary of 15.54 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

4.6014 41.6495 0.1105

Table 31 ­ General Population Transmitter Summary

2.2.4

Configuration 4 - 2 bands, 4 TX antenna connectors (B66a/B25)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (160W)

EIRP (W)

Duty Cycle (%)

6982.328 100

Gain (dBi)
16.4

Frequency (MHz)
1930.7

RF Exposure Level at compliance boundary of 4.43 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

28.3128 103.3135 0.2740

Table 32 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (160W)

EIRP (W)

Duty Cycle (%)

6982.328 100

Gain (dBi)
16.4

Frequency (MHz)
1930.7

RF Exposure Level at compliance boundary of 10.99 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

4.6004 41.6450 0.1105

Table 33 ­ General Population Transmitter Summary

Document 75940792 Report 01 Issue 1

Page 24 of 30

2.2.5

Configuration 5 - 2 bands, 4 TX antenna connectors (B5/B13)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
746.7

RF Exposure Level at compliance boundary of 7.94 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

17.6258 81.5155 0.2162

Table 34 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
746.7

RF Exposure Level at compliance boundary of 21.49 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.4061 30.1179 0.0799

Table 35 ­ General Population Transmitter Summary

2.2.6

Configuration 6 - 2 bands, 4 TX antenna connectors (B1/B3)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
1805.7

RF Exposure Level at compliance boundary of 6.37 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

27.3849 101.6064 0.2695

Table 36 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
1805.7

RF Exposure Level at compliance boundary of 15.89 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

4.4009 40.7321 0.1080

Table 37 ­ General Population Transmitter Summary

Document 75940792 Report 01 Issue 1

Page 25 of 30

2.2.7

Configuration 7 - 2 bands, 4 TX antenna connectors (B12/B14)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
729.7

RF Exposure Level at compliance boundary of 7.99 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

17.4059 81.0053 0.2149

Table 38 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
729.7

RF Exposure Level at compliance boundary of 21.66 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.3685 29.8815 0.0793

Table 39 ­ General Population Transmitter Summary

2.2.8

Configuration 8 - 2 bands, 4 TX antenna connectors (B12/B71)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (240W)

EIRP (W)

Duty Cycle (%)

10471.280 100

Gain (dBi)
16.4

Frequency (MHz)
617.7

RF Exposure Level at compliance boundary of 7.52 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

14.7351 74.5320 0.1977

Table 40 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (240W)

EIRP (W)

Duty Cycle (%)

10471.280 100

Gain (dBi)
16.4

Frequency (MHz)
617.7

RF Exposure Level at compliance boundary of 19.85 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.1148 28.2358 0.0749

Table 41 ­ General Population Transmitter Summary

Document 75940792 Report 01 Issue 1

Page 26 of 30

2.2.9

Configuration 9 - 2 bands, 4 TX antenna connectors (B5/B13)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (160W)

EIRP (W)

Duty Cycle (%)

6982.328 100

Gain (dBi)
16.4

Frequency (MHz)
746.7

RF Exposure Level at compliance boundary of 5.62 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

17.5921 81.4375 0.2160

Table 42 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (160W)

EIRP (W)

Duty Cycle (%)

6982.328 100

Gain (dBi)
16.4

Frequency (MHz)
746.7

RF Exposure Level at compliance boundary of 15.20 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.4049 30.1104 0.0799

Table 43 ­ General Population Transmitter Summary

2.2.10 Configuration 10 - 2 bands, 8 TX antenna connectors (B2/B66a)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
1930.7

RF Exposure Level at compliance boundary of 6.26 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

28.3558 103.3918 0.2742

Table 44 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
1930.7

RF Exposure Level at compliance boundary of 15.53 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

4.6073 41.6763 0.1105

Table 45 ­ General Population Transmitter Summary

Document 75940792 Report 01 Issue 1

Page 27 of 30

2.2.11 Configuration 11 - 1 band, 4 TX antenna connectors (B28)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
758.7

RF Exposure Level at compliance boundary of 7.91 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

17.7598 81.8246 0.2170

Table 46 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (320W)

EIRP (W)

Duty Cycle (%)

13963.670 100

Gain (dBi)
16.4

Frequency (MHz)
758.7

RF Exposure Level at compliance boundary of 21.37 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.4332 30.2870 0.0803

Table 47 ­ General Population Transmitter Summary

2.2.12 Configuration 12 - 2 band, 4 TX antenna connectors (B29/B70)

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (200W)

EIRP (W)

Duty Cycle (%)

8729.706 100

Gain (dBi)
16.4

Frequency (MHz)
717.7

RF Exposure Level at compliance boundary of 6.37 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

17.1203 80.3380 0.2131

Table 48 ­ Occupational Transmitter Summary

Antenna Port

Tx No.

Ant No.

RAT

1

1 1 LTE (200W)

EIRP (W)

Duty Cycle (%)

8729.706 100

Gain (dBi)
16.4

Frequency (MHz)
717.7

RF Exposure Level at compliance boundary of 17.22 m

S Field (W/m2)

E Field (V/m)

H Field (A/m)

2.3427 29.7185 0.0788

Table 49 ­ General Population Transmitter Summary

Document 75940792 Report 01 Issue 1

Page 28 of 30

SECTION 3 DISCLAIMERS AND COPYRIGHT

Document 75940792 Report 01 Issue 1

Page 29 of 30

3.1

DISCLAIMERS AND COPYRIGHT

This report relates only to the actual item/items tested.
This report must not be reproduced, except in its entirety, without the written permission of TÜV SÜD Product Service
© 2017 TÜV SÜD Product Service

Document 75940792 Report 01 Issue 1

Page 30 of 30

ANNEX A REGIONAL REQUIREMENTS

Document 75940792 Report 01 Issue 1

Page A.1 of A.3

Frequency Range (MHz) 0.065 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000
Frequency Range (MHz) 0.003 - 0.15 0.15 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000
Frequency Range (MHz) 0 - 0.3 0.3 - 3 3 - 30 30 - 300 300 - 1500 1500 - 100000
Frequency Range (MHz) 0 - 0.3 0.3 - 3 3 - 30 30 - 300 300 - 1500 1500 - 100000

Power Density (W/m2)
10 f/40 50

Electric Field Strength (V/m) 610 610/f 61 3*f^0.5 137

Magnetic Field Strength (A/m) 1.6/f 1.6/f 0.162 0.008*f^0.5 0.36

Table A.1 ­ EN 62311:2008 Occupational Limits

Power Density (W/m2)
2 f/200 10

Electric Field Strength (V/m) 87 87 87/f^0.5 28 1.375*f^0.5 61

Magnetic Field Strength (A/m) 5 0.73/f 0.73/f 0.073 0.0037*f^0.5 0.16

Table A.2 ­ EN 62311:2008 General Population Limits

Power Density (mW/cm2)
100 900/f^2 1 f/300 5

Electric Field Strength (V/m) 614 1842/f 61.4 -

Magnetic Field Strength (A/m) 1.63 4.89/f 0.163 -

Table A.3 ­ CFR 47 Pt1.1310 (2016) Occupational Limits

Power Density (mW/cm2)
100 180/f^2 0.2 f/1500 1

Electric Field Strength (V/m) 614 824/f 27.5 -

Magnetic Field Strength (A/m) 1.63 2.19/f 0.073 -

Table A.4 ­ CFR 47 Pt1.1310 (2016) General Population Limits

Document 75940792 Report 01 Issue 1

Page A.2 of A.3

Frequency Range (MHz)
10 - 20 20 - 48 48 - 100 100 - 6000 6000 - 150000

Power Density (W/m2)
10 44.72/f^0.5 6.455 0.6455*f^0.5 50

Electric Field Strength (V/m) 61.4 129.8/f^0.25 49.33 15.60*f^0.25 137

Magnetic Field Strength (A/m) 0.163 0.3444/f^0.25 0.1309 0.04138*f^0.25 0.364

Table A.5 ­ Health Canada Safety Code 6 Occupational Limits

Frequency Range (MHz)
10 - 20 20 - 48 48 - 300 300 - 6000 6000 - 15000

Power Density (W/m2)
2 8.944/f^0.5 1.291 0.02619*f^0.6834 10

Electric Field Strength (V/m) 27.46 58.07/f^0.25 22.06 3.142*f^0.3417 61.4

Magnetic Field Strength (A/m) 0.0728 0.1540/f^0.25 0.05852 0.008335*f^0.3417 0.163

Table A.6 ­ Health Canada Safety Code 6 General Population Limits

Frequency Range (MHz)
0.1 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000

Power Density (W/m2)
1000/f^2 10 f/40 50

Electric Field Strength (V/m) 614 614 61.4 3.07*f^0.5 137

Magnetic Field Strength (A/m) 1.63/f 1.63/f 0.163 0.00814*f^0.5 0.364

Table A.7 ­ ARPANSA Radiation Protection Series No.3 Occupational Limits

Frequency Range (MHz)
0.1 - 0.15 0.15 - 1 1 - 10 10 - 400 400 - 2000 2000 - 300000

Power Density (W/m2)
2 f/200 10

Electric Field Strength (V/m) 86.8 86.8 86.8/f^0.5 27.4 1.37*f^0.5 61.4

Magnetic Field Strength (A/m) 4.86 0.729/f 0.729/f 0.0729 0.00364*f^0.5 0.163

Table A.8 ­ ARPANSA Radiation Protection Series No.3 General Population Limits

Document 75940792 Report 01 Issue 1

Page A.3 of A.3



Related FCC IDs: