8,300 BTU 115-Volt Quiet/ECO/Smart Window Air Conditioner with Wi-Fi/App, Remote and Easy Install/No Pre-Assembly SDS
Windmill W1W31 860003069509 0860003069509 1006107722
6,000 BTU 115-Volt Quiet/ECO/Smart Window Air Conditioner with Wi-Fi/App Remote and Easy Install No Pre-Assembly SDS
Windmill W1W12 860003069516 0860003069516 1007461086
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 17 Pages, 266.34KB
Document DEVICE REPORT095e88a6-11e3-454d-962e-767b28c7f48bSAFETY DATA SHEET HCS-2012 APPENDIX D TO §1910.1200 Version 1 Issue date 06-Jun-2017 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING Product identifier Product name Li-MnO2 Button Cell (3V CR2032) Other means of identification Product Code CR2032 3.0V 210mAh Recommended use of the chemical and restrictions on use Recommended use Power supply Uses advised against No information available. Details of the supplier of the safety data sheet Supplier Dongguan Guante Electronics Technology Co., Ltd. Address Hengtai Building, Middle Road Of Dongcheng, Guancheng District, Dongguan City Postal code 523119 Phone +86-769-23102849 FAX +86-769-23061577 E-mail [email protected] Emergency telephone number +86-769-23102849 2. HAZARDS IDENTIFICATION GHS classification Not classified. Label elements Symbols/Pictograms Signal word Hazard statements Precautionary statements Prevention Response Storage Disposal None None Not classified None. None. None. None. Hazards not otherwise classified (HNOC) These chemicals are contained in a sealed can. Risk of exposure occurs only if the battery is mechanically or electrically abused. The most likely risk is acute exposure when a battery vents. Leaking material exposure to skin, eyes may cause irritation. Inhalation of fumes my cause respiratory irritation. Unknown acute toxicity No information available. 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical nature Chemical name Stainless steel Article CAS No 12597-68-1 Weight-% 50.5 _____________________________________________________________________________________________ Page 1 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ Manganese dioxide Perchloric acid, lithium salt Polypropylene Propylene carbonate Polytetrafluoroethylene Graphite Lithium Ethylene glycol dimethyl ether 1313-13-9 7791-03-9 9003-07-0 108-32-7 9002-84-0 7782-42-5 7439-93-2 110-71-4 30.99 4 3.76 3 2.17 2.17 1.91 1.5 4. FIRST AID MEASURES Description of first aid measures General advice In case of accident or unwellness, seek medical advice immediately (show directions for use or safety data sheet if possible). Inhalation If contents of an opened battery are inhaled, remove source of contamination or move victim to fresh air. Obtain medical advice. Skin contact If skin contact with contents of an open battery occurs, as quickly as possible remove contaminated clothing, shoes and leather goods. Immediately flush with lukewarm, gently flowing water for at least 15 minutes. If irritation or pain persists, seek medical attention. Completely decontaminate clothing, shoes and leather goods before reuse or discard. Eye contact If eye contact with contents of an open battery occurs, immediately flush the contaminated eye(s) with lukewarm, gently flowing water for at least 15 minutes while holding the eyelids open. Neutral saline solution may be used as soon as it is available. If necessary, continue flushing during transport to emergency care facility. Take care not to rinse contaminated water into the unaffected eye or onto face. Quickly transport victim to an emergency care facility. Ingestion If ingestion of contents of an open battery occurs, never give anything by mouth if victim is rapidly losing consciousness, or is unconscious or convulsing. Have victim rinse mouth thoroughly with water. DO NOT INDUCE VOMITING. Have victim drink 60 to 240 mL (2-8 oz.) of water. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Have victim rinse mouth with water again. Quickly transport victim to an emergency care facility. Most important symptoms and effects, both acute and delayed These chemicals are contained in a sealed can. Risk of exposure occurs only if the battery is mechanically or electrically abused. The most likely risk is acute exposure when a battery vents. Leaking material exposure to skin, eyes may cause irritation. Inhalation of fumes my cause respiratory irritation. See Section 11 for more information. Indication of any immediate medical attention and special treatment needed Treat symptomatically. 5. FIRE-FIGHTING MEASURES Extinguishing media Suitable extinguishing media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Unsuitable extinguishing media No information available. Specific hazards arising from the chemical Thermal decomposition can lead to release of irritating and toxic gases and vapors. Protective equipment and precautions for firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. Cool containers with flooding quantities of water until well after fire is out. Evacuate personnel to safe areas. _____________________________________________________________________________________________ Page 2 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ 6. ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures Evacuate personnel to safe areas. Remove all sources of ignition. Avoid contact with skin, eyes or clothing. Do not breathe dust/fume/gas/mist/vapors/spray. Do not touch or walk through spilled material. Ensure adequate ventilation, especially in confined areas. Use personal protection recommended in Section 8. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Methods and material for containment and cleaning up Prevent material from contaminating soil and from entering sewers or waterways. Stop the leak if safe to do so. Pick up and transfer to properly labeled containers. 7. HANDLING AND STORAGE Precautions for safe handling Handle in accordance with good industrial hygiene and safety practice. Ensure adequate ventilation, especially in confined areas. Do not breathe dust/fume/gas/mist/vapors/spray. Avoid contact with skin, eyes or clothing. Wash thoroughly after handling. Use personal protection recommended in Section 8. Take precautionary measures against static discharges. Do not eat, drink or smoke when using this product. Conditions for safe storage, including any incompatibilities Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat. Store in accordance with local regulations. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Control parameters Chemical name ACGIH TLV Manganese dioxide (CAS #: TWA: 0.02 mg/m3 Mn 1313-13-9) TWA: 0.1 mg/m3 Mn Graphite (CAS #: 7782-42-5) TWA: 2 mg/m3 respirable fraction all forms except graphite fibers OSHA PEL (vacated) Ceiling: 5 mg/m3 Ceiling: 5 mg/m3 Mn - NIOSH IDLH IDLH: 500 mg/m3 Mn TWA: 1 mg/m3 Mn STEL: 3 mg/m3 Mn IDLH: 1250 mg/m3 TWA: 2.5 mg/m3 natural respirable dust Denmark TWA: 0.2 mg/m3 TWA: 2.5 mg/m3 European Union - - Chemical name Manganese dioxide (CAS #: 1313-13-9) Latvia TWA: 0.3 mg/m3 Polypropylene (CAS #: 9003-07-0) Propylene carbonate (CAS #: 108-32-7) Graphite (CAS #: 7782-42-5) Ethylene glycol dimethyl ether (CAS #: 110-71-4) TWA: 5 mg/m3 TWA: 2 mg/m3 TWA: 2 mg/m3 TWA: 10 mg/m3 France - TWA: 2 mg/m3 - Finland TWA: 0.2 mg/m3 TWA: 0.1 mg/m3 TWA: 2 mg/m3 - Germany TWA: 0.2 mg/m3 TWA: 0.02 mg/m3 Ceiling / Peak: 1.6 mg/m3 Ceiling / Peak: 0.16 mg/m3 TWA: 0.5 mg/m3 - - TWA: 1.5 mg/m3 TWA: 4 mg/m3 - Italy - - Chemical name Manganese dioxide (CAS #: 1313-13-9) Poland TWA: 0.3 mg/m3 Portugal TWA: 0.2 mg/m3 Spain TWA: 0.2 mg/m3 Switzerland TWA: 0.5 mg/m3 Netherlands - Chemical name Manganese dioxide (CAS #: 1313-13-9) Norway TWA: 1 mg/m3 TWA: 0.1 mg/m3 STEL: 1 ppm STEL: 0.1 mg/m3 United Kingdom TWA: 0.5 mg/m3 Australia 1 mg/m3 Austria STEL 2 mg/m3 TWA: 0.5 mg/m3 Belgium - _____________________________________________________________________________________________ Page 3 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ Graphite (CAS #: 7782-42-5) TWA: 5 mg/m3 - TWA: 2 mg/m3 TWA: 10 mg/m3 TWA: 4 mg/m3 STEL: 5 mg/m3 STEL: 2 mg/m3 STEL: 10 mg/m3 STEL: 4 mg/m3 3 mg/m3 STEL 10 mg/m3 - TWA: 5 mg/m3 Appropriate engineering controls Use local exhaust ventilation or other engineering controls to control sources of dust, mist, fumes and vapor. Individual protection measures, such as personal protective equipment Respiratory protection Not necessary under normal conditions. If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved respiratory protection should be worn. Positive-pressure supplied air respirators may be required for high airborne contaminant concentrations. Respiratory protection must be provided in accordance with current local regulations. Hand protection Not necessary under normal conditions. Wear neoprene or natural rubber material gloves if handling an open or leaking battery. Eye/face protection Not necessary under normal conditions, Wear safety glasses if handling an open or leaking battery. Skin and body protection Not necessary under normal conditions, Wear neoprene or nitride rubber gloves if handling an open or leaking battery. 9. PHYSICAL AND CHEMICAL PROPERTIES Information on basic physical and chemical properties Appearance Solid Color No information available Odor No information available Odor threshold Not determined pH Not determined Melting point/freezing point Not determined Boiling point / boiling range Not determined Flash point Not determined Evaporation rate Not determined Flammability (solid, gas) Not flammable Flammability limit in air Not determined Vapor pressure Not determined Vapor density Not determined Density Not determined Relative density Not determined Water solubility Not determined Partition coefficient (LogPow) Not determined Autoignition temperature Not determined Decomposition temperature Not determined Kinematic viscosity Not determined Dynamic viscosity Not determined Explosive properties Not an explosive Oxidizing properties Not determined Other information No information available 10. STABILITY AND REACTIVITY Reactivity Stable under recommended storage and handling conditions (see SECTION 7, handling and storage). _____________________________________________________________________________________________ Page 4 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ Chemical stability Stable under normal conditions. Possibility of hazardous reactions None under normal processing. Conditions to avoid Extremes of temperature and direct sunlight. Incompatible materials None known based on information supplied. Hazardous decomposition products None under normal use conditions 11. TOXICOLOGICAL INFORMATION Information on likely routes of exposure Inhalation No known effect based on information supplied. Eye contact No known effect based on information supplied. Skin contact No known effect based on information supplied. Ingestion No known effect based on information supplied. Information on toxicological effects Acute toxicity Chemical name Oral LD50 Manganese dioxide (CAS #: >3480 mg/kg ( Rat ) male 1313-13-9) Polypropylene (CAS #: >5 g/kg 9003-07-0) Propylene carbonate (CAS #: 108-32-7) 29000 mg/kg ( Rat ) > 5000 mg/kg bw (Rat) Graphite (CAS #: 7782-42-5) > 2000 mg/kg (rat) Ethylene glycol dimethyl ether = 5370 mg/kg ( Rat ) (CAS #: 110-71-4) Dermal LD50 - - > 20 mL/kg ( Rabbit ) 2000 mg/kg bw (Rabbit) - Inhalation LC50 - - - > 2000 mg/m³/4h (rat) - Skin corrosion/irritation Non-irritating to the skin. Serious eye damage/eye irritation No eye irritation. Sensitization No information available. Germ cell mutagenicity No information available. Carcinogenicity Chemical name Polypropylene (CAS #: 9003-07-0) Polytetrafluoroethylene (CAS #: 9002-84-0) ACGIH - - IARC Group 3 Group 3 NTP - - OSHA - - Reproductive toxicity No information available. _____________________________________________________________________________________________ Page 5 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ STOT - single exposure No information available. STOT - repeated exposure No information available. Aspiration hazard No information available. 12. ECOLOGICAL INFORMATION Ecotoxicity Chemical name Manganese dioxide (CAS #: 1313-13-9) Propylene carbonate (CAS #: 108-32-7) Graphite (CAS #: 7782-42-5) Algae/Aquatic plants EC50 Fish LC50 > 100 other: v/v saturated > 100 other: % v/v saturated solution 72h Desmodesmus solution 96h Oncorhynchus subspicatus mykiss 500mg/L72 h Desmodesmus 1000mg/L 96 h Cyprinus carpio subspicatus semi-static > 900 mg/L 72h Desmodesmus 5300mg/L 96 h Leuciscus idus subspicatus static > 1000 mg/L 96h Cyprinus carpio > 100 mg/l/72h > 100 mg/l/96h (Danio rerio) (Pseudokirchneriella subcapitata) Crustacea EC50 > 100 other: % v/v saturated solution 48h Daphnia magna 500mg/L 48 h Daphnia magna > 1000 mg/L 24h 48h Daphnia magna > 100 mg/l/48h (Daphnia magna) Persistence and degradability No information available. Bioaccumulative potential Chemical name Manganese dioxide (CAS #: 1313-13-9) Propylene carbonate (CAS #: 108-32-7) Ethylene glycol dimethyl ether (CAS #: 110-71-4) Partition coefficient (LogPow) <0 0.48 -0.21 Mobility in soil No information available. Other adverse effects No information available. 13. DISPOSAL CONSIDERATIONS Waste treatment methods Disposal of wastes Contaminated packaging Disposal should be in accordance with applicable regional, national and local laws and regulations. Disposal should be in accordance with applicable regional, national and local laws and regulations. 14. TRANSPORT INFORMATION DOT / IMDG / IATA UN/ID No. UN proper shipping name Hazard class Packing group Special precautions Marine pollutant 3090 LITHIUM METAL BATTERIES(includinglithium alloy batteries) 9 No information available Non-marine pollutant _____________________________________________________________________________________________ Page 6 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ 15. REGULATORY INFORMATION International inventories Component AICS Stainless steel - 12597-68-1 ( 50.5 ) Manganese dioxide X 1313-13-9 ( 30.99 ) Perchloric acid, X lithium salt 7791-03-9 ( 4 ) Polypropylene X 9003-07-0 ( 3.76 ) Propylene X carbonate 108-32-7 ( 3 ) Polytetrafluoroethyle X ne 9002-84-0 ( 2.17 ) Graphite X 7782-42-5 ( 2.17 ) Lithium X 7439-93-2 ( 1.91 ) Ethylene glycol X dimethyl ether 110-71-4 ( 1.5 ) "-" Not Listed "X" Listed DSL/NDSL EINECS/ELI NCS - - X X X X ENCS X X X - X X X X X - X X X Exempt X X X X X X IECSC X X X X X X X X X KECL X X X X X X X X PICCS X - X X X X X X TSCA X X X X X X X X US Federal Regulations SARA 313 Chemical name Manganese dioxide - 1313-13-9 Ethylene glycol dimethyl ether - 110-71-4 SARA 313 - Threshold Values % 1.0 1.0 SARA 311/312 Hazard Categories Not applicable CWA (Clean Water Act) Not applicable CERCLA Not applicable US State Regulations California Proposition 65 This product does not contain any Proposition 65 chemicals U.S. State Right-to-Know Regulations Chemical name New Jersey Manganese dioxide X 1313-13-9 Graphite X 7782-42-5 Lithium X 7439-93-2 Ethylene glycol dimethyl ether X 110-71-4 Massachusetts - X X X Pennsylvania X - X X _____________________________________________________________________________________________ Page 7 / 8 Product name Li-MnO2 Button Cell (3V CR2032) Revision date 06-Jun-2017 _____________________________________________________________________________________________ 16. OTHER INFORMATION Revision note Issue date Revision date Revision note 06-Jun-2017 06-Jun-2017 Not applicable Key or legend to abbreviations and acronyms used in the safety data sheet TWA - TWA (Time Weighted Average) STEL - STEL (Short Term Exposure Limit) Ceiling - Maximum limit value TSCA - Toxic Substances Control Act Section 8(b) Inventory DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List EINECS/ELINCS - European INventory of Existing Commercial chemical Substances/European LIst of Notified Chemical Substances ENCS - Japanese Existing and New Chemical Substances IECSC - Chinese Inventory of Existing Chemical Substances KECL - Korea Existing Chemicals List PICCS - The Philippine Inventory of Chemicals and Chemical Substances AICS - The Australian Inventory of Chemical Substances Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. -------- End of Safety Data Sheet -------- _____________________________________________________________________________________________ Page 8 / 8 SAFETY DATA SHEET Issuing Date 09-Feb-2021 Revision Date 09-Feb-2021 Revision Number 2 NGHS / English _____________________________________________________________________________________________ The supplier identified below generated this SDS using the UL SDS template. UL did not test, certify, or approve the substanc e described in this SDS, and all information in this SDS was provided by the supplier or was reproduced from publically available regulatory data sources. UL makes no representations or warranties regarding the completeness or accuracy of the information in this SDS and disclaims all liability in connection with the use of this information or the substance described in this SDS. The layout, appearance and format of this SDS is © 2014 UL LLC. All rights reserved. _____________________________________________________________________________________________ 1. IDENTIFICATION Product identifier Product Name Windmill AC Unit With Refrigerant Other means of identification Product Code(s) 1620126 Recommended use of the chemical and restrictions on use Recommended Use Restrictions on use Appliance containing Compressed Gas (not Freon) No information available Details of the supplier of the safety data sheet Supplier Identification The Air Lab, Inc. (DBA Windmill) Address 108 Leonard Street Apt 2B New York NY 10013 US Telephone Phone:4073100607 E-mail Emergency telephone number Company Emergency Phone Number [email protected] 4073100607 2. HAZARDS IDENTIFICATION Classification Flammable gases Category 1 _____________________________________________________________________________________________ Page 1 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ Gases under pressure Compressed Gas Appearance No data available Physical state Compressed gas Gas GHS Label elements, including precautionary statements Danger Hazard statements Extremely flammable gas Contains gas under pressure; may explode if heated Odor No data available Precautionary Statements - Prevention Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking Precautionary Statements - Response Skin Eliminate all ignition sources if safe to do so Fire Leaking gas fire: Do not extinguish, unless leak can be stopped safely Precautionary Statements - Storage Store in well-ventilated place Protect from sunlight. Store in a well-ventilated place Other information Unknown acute toxicity 100 % of the mixture consists of ingredient(s) of unknown toxicity 100 % of the mixture consists of ingredient(s) of unknown acute oral toxicity 100 % of the mixture consists of ingredient(s) of unknown acute dermal toxicity 100 % of the mixture consists of ingredient(s) of unknown acute inhalation toxicity (gas) 100 % of the mixture consists of ingredient(s) of unknown acute inhalation toxicity (vapor) 100 % of the mixture consists of ingredient(s) of unknown acute inhalation toxicity (dust/mist) Substance 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical name CAS No Weight-% Hazardous Material Date HMIRA filed and Information Review Act date exemption granted registry number (HMIRA (if applicable) _____________________________________________________________________________________________ Page 2 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ registry #) Methylene fluoride 75-10-5 100 - - Description of first aid measures Inhalation Eye contact Skin contact Ingestion 4. FIRST AID MEASURES Remove to fresh air. Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a physician. In case of contact with liquefied gas, thaw frosted parts with lukewarm water. Clean mouth with water and drink afterwards plenty of water. Most important symptoms and effects, both acute and delayed Symptoms No information available. Indication of any immediate medical attention and special treatment needed Note to physicians Treat symptomatically. 5. FIRE-FIGHTING MEASURES Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Large Fire CAUTION: Use of water spray when fighting fire may be inefficient. Unsuitable extinguishing media DO NOT EXTINGUISH A LEAKING GAS FIRE UNLESS LEAK CAN BE STOPPED. Specific hazards arising from the Cylinders may rupture under extreme heat. Damaged cylinders should be handled only by chemical specialists. Containers may explode when heated. Ruptured cylinders may rocket. Hazardous Combustion Products Carbon oxides. Explosion Data Sensitivity to Mechanical Impact Yes. Sensitivity to Static Discharge Yes. Special protective equipment for Firefighters should wear self-contained breathing apparatus and full firefighting turnout fire-fighters gear. Use personal protection equipment. 6. ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures Personal precautions ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Take precautionary measures against static discharges. Contents under pressure. Empty containers pose a potential fire and explosion hazard. Do not cut, puncture of weld _____________________________________________________________________________________________ Page 3 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ containers. Methods and material for containment and cleaning up Methods for containment Prevent further leakage or spillage if safe to do so. Methods for cleaning up Pick up and transfer to properly labeled containers. 7. HANDLING AND STORAGE Precautions for safe handling Advice on safe handling Contents under pressure. Empty containers pose a potential fire and explosion hazard. Do not cut, puncture of weld containers. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Take precautionary measures against static discharges. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Conditions for safe storage, including any incompatibilities Storage Conditions Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from sunlight. Control parameters Exposure Limits 8. EXPOSURE CONTROLS/PERSONAL PROTECTION This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region specific regulatory bodies. Appropriate engineering controls Engineering controls Showers Eyewash stations Ventilation systems. Individual protection measures, such as personal protective equipment Eye/face protection No special protective equipment required. Skin and body protection No special protective equipment required. Respiratory protection No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required. General hygiene considerations Handle in accordance with good industrial hygiene and safety practice. 9. PHYSICAL AND CHEMICAL PROPERTIES Information on basic physical and chemical properties _____________________________________________________________________________________________ Page 4 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ Physical state Appearance Odor Color Odor Threshold Compressed gas; Gas No data available No data available No information available No data available Property Values pH No data available Melting / freezing point No data available Boiling point / boiling range No data available Flash Point No data available Evaporation Rate No data available Flammability (solid, gas) No data available Flammability Limit in Air Upper flammability limit No data available Lower flammability limit No data available Vapor pressure No data available Vapor density No data available Relative density No data available Water Solubility Moderately soluble Solubility(ies) No data available Partition coefficient: n-octanol/water NA Autoignition temperature No data available Decomposition temperature No data available Kinematic viscosity No data available Dynamic viscosity No data available Other Information Explosive properties Oxidizing properties Softening Point Molecular Weight VOC Content (%) Liquid Density Bulk Density Particle Size Particle Size Distribution No information available No information available No information available No information available No information available No information available No information available No information available No information available Remarks Method None known None known None known None known None known None known None known None known None known None known None known None known None known None known None known 10. STABILITY AND REACTIVITY Reactivity No information available. Chemical stability Stable under normal conditions. Possibility of Hazardous Reactions None under normal processing. Hazardous Polymerization Hazardous polymerization does not occur. Conditions to avoid Excessive heat. Incompatible materials None known based on information supplied. Hazardous Decomposition Products Carbon oxides. 11. TOXICOLOGICAL INFORMATION _____________________________________________________________________________________________ Page 5 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ Information on likely routes of exposure Product Information Inhalation Specific test data for the substance or mixture is not available. Eye contact Specific test data for the substance or mixture is not available. Skin contact Specific test data for the substance or mixture is not available. Ingestion Specific test data for the substance or mixture is not available. Symptoms related to the physical, chemical and toxicological characteristics Symptoms No information available. Numerical measures of toxicity Acute toxicity Unknown acute toxicity 100 % of the mixture consists of ingredient(s) of unknown toxicity 100 % of the mixture consists of ingredient(s) of unknown acute oral toxicity 100 % of the mixture consists of ingredient(s) of unknown acute dermal toxicity 100 % of the mixture consists of ingredient(s) of unknown acute inhalation toxicity (gas) 100 % of the mixture consists of ingredient(s) of unknown acute inhalation toxicity (vapor) 100 % of the mixture consists of ingredient(s) of unknown acute inhalation toxicity (dust/mist) Component Information Chemical name Methylene fluoride Oral LD50 - Dermal LD50 - Inhalation LC50 > 520000 ppm ( Rat ) 4 h Delayed and immediate effects as well as chronic effects from short and long-term exposure Skin corrosion/irritation No information available. Serious eye damage/eye irritation No information available. Respiratory or skin sensitization No information available. Germ cell mutagenicity No information available. Carcinogenicity No information available. Reproductive toxicity STOT - single exposure STOT - repeated exposure Aspiration hazard No information available. No information available. No information available. No information available. 12. ECOLOGICAL INFORMATION _____________________________________________________________________________________________ Page 6 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ Ecotoxicity The environmental impact of this product has not been fully investigated. Persistence and Degradability Bioaccumulation No information available. No information available. Mobility Other adverse effects Waste treatment methods Waste from residues/unused products Contaminated packaging US EPA Waste Number No information available. No information available. 13. DISPOSAL CONSIDERATIONS Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation. Do not reuse empty containers. D001 California Waste Codes 331 14. TRANSPORT INFORMATION DOT Proper Shipping Name Hazard Class NOT REGULATED NON-REGULATED N/A TDG Not applicable MEX Not applicable ICAO Not applicable IATA Not applicable IMDG/IMO Hazard Class Not applicable N/A RID Not applicable ADR Not applicable ADN Not applicable 15. REGULATORY INFORMATION Safety, health and environmental regulations/legislation specific for the substance or mixture _____________________________________________________________________________________________ Page 7 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ International Regulations The Montreal Protocol on Substances that Deplete the Ozone Layer Not applicable The Stockholm Convention on Persistent Organic Pollutants Not applicable The Rotterdam Convention Not applicable International Inventories TSCA DSL/NDSL EINECS/ELINCS ENCS KECL PICCS AICS Contact supplier for inventory compliance status. Contact supplier for inventory compliance status. Contact supplier for inventory compliance status. Contact supplier for inventory compliance status. Contact supplier for inventory compliance status. Contact supplier for inventory compliance status. Contact supplier for inventory compliance status. Legend TSCA - United States Toxic Substances Control Act Section 8(b) Inventory DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List EINECS/ELINCS - European Inventory of Existing Chemical Substances/European List of Notified Chemical Substances ENCS - Japan Existing and New Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances PICCS - Philippines Inventory of Chemicals and Chemical Substances AICS - Australian Inventory of Chemical Substances US Federal Regulations SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 SARA 311/312 Hazard Categories Should this product meet EPCRA 311/312 Tier reporting criteria at 40 CFR 370, refer to Section 2 of this SDS for appropriate classifications. Under the amended regulations at 40 CFR 370, EPCRA 311/312 Tier II reporting for the 2017 calendar year will need to be consistent with updated hazard classifications. CWA (Clean Water Act) This product contains the following substances which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42) Chemical name Methylene fluoride 75-10-5 CWA - Reportable Quantities CWA - Toxic Pollutants X CWA - Priority Pollutants CWA - Hazardous Substances CERCLA This material, as supplied, does not contain any substances regulated as hazardous substances under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) (40 CFR 302) or the Superfund Amendments and Reauthorization Act (SARA) (40 CFR 355). There may be specific reporting requirements at the local, regional, or state level pertaining to releases of this material US State Regulations California Proposition 65 _____________________________________________________________________________________________ Page 8 / 9 1620126 - Windmill Refrigerant Revision Date 09-Feb-2021 _____________________________________________________________________________________________ This product does not contain any Proposition 65 chemicals. U.S. State Right-to-Know Regulations This product may contain substances regulated by state right-to-know regulations. Chemical name Methylene fluoride 75-10-5 New Jersey Massachusetts Pennsylvania X Rhode Island Illinois 16. OTHER INFORMATION NFPA HMIS Health hazards 1 Health hazards 1 Flammability 4 Flammability 4 Instability 0 Physical hazards 0 Physical and Chemical Properties Personal Protection X Prepared By Product Stewardship 23 British American Blvd. Latham, NY 12110 1-800-572-6501 Issuing Date 09-Feb-2021 Revision Date 09-Feb-2021 Revision Note No information available Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text End of Safety Data Sheet _____________________________________________________________________________________________ Page 9 / 9iTextSharp 5.0.6 (c) 1T3XT BVBA