220500032HZH-001 LM79

judy.hu

Download

Technical Files Download | Artika | Artika

Descargar

| Artika | Artika

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 11 Pages, 1.42MB

Document DEVICE REPORT220500032hzh-001-lm79-898be4
ARTIKA FOR LIVING
TEST REPORT
SCOPE OF WORK PERFORMANCE TEST ACCORDING TO LM79 - LED SOURCE PRODUCTS MODEL NO.: 36BOL-DS-followed by six characters

REPORT NUMBER 220500032HZH-001

ISSUE DATE 9-May-2022

[REVISED DATE] [None]

PAGES 10

DOCUMENT CONTROL NUMBER Test Template _ HZH_ LM79 ED2.0 © 2022 INTERTEK

TEST REPORT

Address: 4th floor,Building 4#,No.22,22nd Street, Qiantang District, Hangzhou, 310018 China Telephone: +86 571 28997803 Facsimile: +86 571 28997888 www.intertek.com

REPORT NO. 220500032HZH-001
TEST OF LM-79 For <LED Luminaire>
MODEL NO. 36BOL-DS-followed by six characters
RENDERED TO
ARTIKA FOR LIVING 1756 50th avenue, Qc, CanadaH8T 2V5
STATEMENT OF ACCREDITATION AND LIMITATION This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

STANDARDS USED

The following standards or test guides were used in part or totally to test each specimen:

ORGANIZATION IDENTIFIER

TITLE

IESNA

LM-79-2008

Approved Method for Electrical and Photometric Measurements

of Solid-State Lighting Products

ANSI / ANSLG C78.377-2015 Specifications of the Chromaticity of Solid State Lighting Products

DESCRIPTION OF SAMPLE The client submitted LED produced on May of 2022, total 1 sample of model number 20365. The sample was received by Intertek Hangzhou on May 5, 2022 in normal condition, and the sample was tested as received.
DATES OF TESTS May 5, 2022 to May 9, 2022

Issued by Intertek Testing Services Zhejiang ltd Hangzhou branch Test Location: 4th floor,Building 4#,No.22,22nd Street,Qiantang District, Hangzhou, 310018 China

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Version: 01-August-2018

Page 2 of 11

Test Template _ HZH_ LM79 ED2.0

TEST REPORT

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

SUMMARY

TEST MODEL: 36BOL-DS-followed by six characters

DFAMILY MODEL: NA

DESIGN CATEGORY: Lighting Technology

RATED VALUE 220-240VAC, 50/60Hz, 13W

COLOR-TUNABLE: N/A

REMARK

According to applicant's requirement, all measured regulated to 120V AC,60Hz.

Criteria Input Voltage(Vac)
Frequency(Hz) Total Power (W)
Power Factor Total Lumen Output (Lumens)
Luminaire Efficacy (LPW) Correlated Color Temperature (CCT - K)
Color Rendering Index (CRI) ­ Ra Color Rendering Index (CRI) - R9
Duv Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v')

Result 120 60 12.52 0.977 433.2 34.60 3110 91.7 56 -0.0011 0.4279 0.3981 0.2473 0.5177

******************************************* End of Page ******************************************

Version: 01-August-2018

Page 3 of 11

Test Template _ HZH_LM79 ED2.0

TEST REPORT

Ningbo Promise Electronics Co., Ltd. Intertek Report: No: 220300135HZH-002

EQUIPMENT LIST

Equipment Used
Fluke Temperature Meter

Control Number
EH1513

Power Supply for integrating sphere

EH2324-2

Digital Power Meter for integrating sphere

EH2106

Integrating sphere

EH2108-2

Spectroradiometer

EH2385

Power source for Goniophotometer System

EH2453-1

Digital Power Meter for goniophotometer

EH2453-3

Goniophotometer System

EH2453

Model Number
52II APW-105N
2053AH
2m MCS-2000 DPS1060_V200
WT-310E
GO-R5000

Manufacturer
Fluke Allpower
XITRON
Sensing Sensing Everfine
Everfine
Everfine

******************************************* End of Page ******************************************

Version: 01-August-2018

Page 4 of 11

Test Template _ HZH_ CEC PRLU ED2.0

TEST REPORT
TEST METHODS

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

SEASONING IN SAMPLE ORIENTATION ­ LED PRODUCTS No seasoning was performed in accordance with IESNA LM-79
TEST CONDITION
The voltage of power supply (RMS value) applied for all EUTs was regulated to 120VAC or other rated voltage within ±0.2 percent at 60Hz. Each EUT was pre-conditioned to stabilization status according to IESNA LM-79 before testing. Temperature of 25ºC±1 was maintained for initial photometric testing.

PHOTOMETRIC AND ELECTRICAL MEASUREMENTS ­ DISTRIBUTION METHOD
Total light output (luminous flux) and light distribution were measured using a Go-R5000 Type-C Rotating Mirror Goniophotometer measurement system, Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Electrical measurements including voltage, current, and power were measured using the power analyzer. Some graphics were created with Photometrics Plus software.

PHOTOMETRIC AND ELECTRICAL MEASUREMENTS ­ INTEGRATING SPHERE METHOD
A spectroradiometer and two meters sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Electrical measurements including voltage, current, and power were measured using the power analyzer.

******************************************* End of Page ******************************************

Version: 01-August-2018

Page 5 of 11

Test Template _ HZH_LM79 ED2.0

TEST REPORT

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

RESULTS OF TESTS PHOTOMETRIC AND ELECTRICAL MEASUREMENTS AT 25°C

MODEL NO .
36BOL-DSfollowed by six
characters

INPUT VOLTAGE
(Vac)
120.0

INPUT CURRENT
(A)
0.107

INPUT POWER (WATTS)
12.52

INPUT POWER FACTOR
0.977

CURRENT ATHD (%)
--

ABSOLUTE LUMINOUS
FLUX (LUMENS)
433.2

EFFICACY STABILIZED (LUMENS TIME PER WATT) (MIN.)

34.60

30

COLOR MEASUREMENTS AT 25°C (SPHERE METHOD)

CCT (K)
3110

CRI CRI -RA -R9

CIE 31'

CIE 31'

CIE 76'

CIE 76'

CHROMATICITY CHROMATICITY CHROMATICITY CHROMATICITY

COORDINATE COORDINATE COORDINATE COORDINATE

DUV

(X)

(Y)

(U')

(V')

91.7 56 -0.0011 0.4279

0.3981

0.2473

0.5177

SPECTRAL DATA OVER VISIBLE WAVELENGTHS

******************************************* End of Page ******************************************

Version: 01-August-2018

Page 6 of 11

Test Template _ HZH_LM79 ED2.0

TEST REPORT
RESULTS OF TESTS(CONT'D) ZONAL LUMEN SUMMARY AND PERCENTAGES AT 25°C(DISTRIBUTE METHOD)

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

Zone
0-30 0-60 0-90 0-120 0-180

Lumens (lm)
132.3 396.8 430.3 432.9 433.2

INTENSITY (CANDLEPOWER) SUMMARY AT 25°C ­ CANDELAS

% Luminaire %
30.5 91.6 99.3 99.9 100.0

HORIZONTAL

Angle

0

22.5

45

67.5 90

0

0.9

0.9

0.9

0.9 0.9

5 751.5 841.9 885.6 79.0 0.2

10 749.9 832.7 873.9 355.6 1.2

15 744.2 819.4 853.1 554.9 3.5

20 728.6 803.2 831.7 616.0 4.9

25 709.5 780.1 806.7 634.6 5.8

30 686.3 756.3 778.4 631.4 6.3

35 659.1 721.2 742.5 624.9 6.4

40 615.8 665.5 680.3 593.9 6.3

45 538.0 582.2 608.4 530.6 5.9

50 475.7 510.0 517.6 466.0 5.4

55 413.0 435.2 431.8 380.8 4.6

60 157.5 168.8 244.3 270.1 3.8

65 58.6 58.6

47.3 102.3 2.8

70 42.3 40.8

27.1 13.6 1.6

75 28.3 26.3

13.9

6.6

0.6

80 18.3 16.7

6.1

3.1 0.1

85 14.1 13.5

4.3

2.2 0.0

90 13.0 12.4

4.0

1.8 0.0

******************************************* End of Page ******************************************

VERTICAL

Version: 01-August-2018

Page 7 of 11

Test Template _ HZH_LM79 ED2.0

TEST REPORT
RESULTS OF TESTS(CONT'D)
ILLUMINANCE - CONE OF LIGHT

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

Version: 01-August-2018

Page 8 of 11

Test Template _ HZH_LM79 ED2.0

TEST REPORT
ISOILLUMINATION PLOT

Ningbo Promise Electronics Co., Ltd. Intertek Report: No: 220300135HZH-002

******************************************* End of Page *************************************

Version: 01-August-2018

Page 9 of 11

Test Template _ HZH_ CEC PRLU ED2.0

TEST REPORT
PICTURES:

Overview

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

******************************************* End of Page *************************************

Version: 01-August-2018

Page 10 of 11

Test Template _ HZH_LM79 ED2.0

TEST REPORT

ARTIKA FOR LIVING Intertek Report: No: 220500032HZH-001

CONCLUSION 1. The results tabulated in this report are representative of the actual test samples submitted for this
report only. Compliance to the referenced specification requirements was not determined in this report.
Attachment: None

In Charge of Tests: Judy Hu

Report Reviewed By: Meng Wang

Engineer Lighting Division

Reviewer Lighting Division

******************************************* End of Page ******************************************

Version: 01-August-2018

Page 11 of 11

Test Template _ HZH_LM79 ED2.0

