72834RRF.005

pmvc

72834RRF.005s

Salto Systems S.L E10M XS4 Mini Electronic Lock UKCE10M UKCE10M e10m

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 23 Pages, 2.11MB

Document DEVICE REPORTGetApplicationAttachment.html?id=6340185
DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

ISED CABid: ES1909
Lab. Company Number: 4621A
Test Report
USA FCC Part 15.225, 15.209 CANADA RSS-210, RSS-Gen

Test Report No: NIE: 72834RRF.005

(*) Identification of item tested (*) Trademark

XS4 Mini+ electronic lock series including all mechanical variants
SALTO

(*) Model and/or type reference

E10M (Type reference: E1517)

Other identification of the product (*) Features Applicant Test method requested, standard
Summary Approved by (name / position & signature)
Date of issue

FCC ID: UKCE10M IC: 10088A-E10M
Features: Bluetooth LE HW version: 1.0 SW version: 0196 (Control FW), 0000 (Motor FW)
0187 (BLE Stack FW), 0186 (FUS FW)
SALTO SYSTEMS, S.L. Arkotz 9, Polígono Lanbarren 20180, Oiartzun, Gipuzkoa, SPAIN
USA FCC Part 15.225 (10-1-21 Edition): Operation within the band 13.110 -14.010. USA FCC Part 15.209 (10-1-21 Edition): Radiated emission limits, general requirements. CANADA RSS-210 Issue 10 (December 2019). CANADA RSS-Gen Issue 5 (March 2019). ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.
IN COMPLIANCE

Rafael López EMC Consumer & RF Lab. Manager
2022-12-21

2022.12. 21 12:07:15 +01'00'

Report template No

FDT08_24 (*) "Data provided by the client"

Report No: (NIE) 72834RRF.005

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Index
Competences and guarantees ......................................................................................................................3 General conditions.........................................................................................................................................3 Uncertainty.....................................................................................................................................................3 Data provided by the client ............................................................................................................................4 Usage of samples ..........................................................................................................................................4 Test sample description.................................................................................................................................5 Identification of the client ...............................................................................................................................6 Testing period and place ...............................................................................................................................6 Document history...........................................................................................................................................6 Environmental conditions ..............................................................................................................................6 Remarks and comments................................................................................................................................7 Testing verdicts..............................................................................................................................................8 Summary .......................................................................................................................................................8 Appendix A: Test results................................................................................................................................9

Report No: (NIE) 72834RRF.005

Page 2 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Competences and guarantees
DEKRA Testing and Certification S.A.U. is a testing laboratory accredited by the National Accreditation Body (ENAC -Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
DEKRA Testing and Certification S.A.U. is an FCC-recognized accredited testing laboratory with appropriate scope of accreditation that covers the performed tests in this report.
DEKRA Testing and Certification S.A.U. is an ISED-recognized accredited testing laboratory, CABid: ES1909, Company Number: 4621A, with the appropriate scope of accreditation that covers the performed tests in this report.
In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.A.U. has a calibration and maintenance program for its measurement equipment.
DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification S.A.U. at the time of performance of the test.
DEKRA Testing and Certification S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test.
The results presented in this Test Report apply only to the particular item under test established in this document.
IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification S.A.U.
General conditions
1. This report is only referred to the item that has undergone the test.
2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities.
3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification S.A.U.
4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification S.A.U. and the Accreditation Bodies.
Uncertainty
Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification internal document PODT000. The total uncertainty of the measurement system for the radiated emissions of EUT from 9 kHz to 30 MHz is: Measurement uncertainty  ±3.08 dB (with factor k = 2).
The total uncertainty of the measurement system for the radiated emissions of EUT from 30 MHz to 200 MHz is: Measurement uncertainty  ±5.35 dB (with factor k = 2).
The total uncertainty of the measurement system for the conducted testing of EUT is: Frequency Tolerance of the Carrier Signal: Measurement uncertainty  ± 12.3 kHz Occupied Bandwidth  ± 1.70 kHz Field strength of emissions within the band  ± 3.44 dB

Report No: (NIE) 72834RRF.005

Page 3 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Data provided by the client
The following data has been provided by the client:
1. Information relating to the description of the sample ("Identification of the item tested", "Trademark", "Model and/or type reference tested").
2. The sample consists of a XS4 Mini+ electronic lock series with RFID Mifare (ISO 14443A standard based) and Bluetooth LE technology. Plastic enclosure.
DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by the client and that may affect the validity of results.
Usage of samples
Samples undergoing test have been selected by: The client.

Id S/01 S/02
S/02

Control Number 72834_6.1 72834_7.1
72834_10.1

Description
XS4 Mini+ electronic lock
XS4 Mini+ electronic lock, conducted sample
Battery holder

Model E10M E10M
--

Notes referenced to samples during the project: Id S/01 S/02

Serial Nº --
--

Date of Reception 2022-07-07
2022-07-07

--

2022-07-07

Type Sample used for radiated test Sample used for conducted test

Application Element Under Test Element Under Test
Element Under Test

Report No: (NIE) 72834RRF.005

Page 4 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Test sample description

Ports..................................... :
Supplementary information to the ports..................................... : Rated power supply .................... :
Rated Power ............................... : Clock frequencies ....................... : Other parameters........................: Software version ......................... : Hardware version........................: Dimensions in cm (W x H x D)....: Mounting position........................:
Modules/parts ............................. :
Accessories (not part of the test item) ............................................: Documents as provided by the applicant...................................... :

Port name and description
--

Cable

Specified Attached max during test
length [m]

Shielded

[ ]

[ ]

Coupled to
patient(3)
[ ]

--

Voltage and Frequency

Reference poles

L1 L2 L3

N

PE

[ ] AC:

[] [] [] [] []

[X] DC: 4.5 Vdc (3 x LR03 batteries). Max: 5V, Min: 3.2 V (perform opening) / 3V (operate)

--

32.768kHz, 27.12MHz, 32MHz

N/A

0196 (Control FW) + 0000 (Motor FW) + 0187 (BLE Stack FW) + 0186 (FUS FW)

1.0

5.85 x 12.7 x 2.25 cm

[ ] Table top equipment

[ ] Wall/Ceiling mounted equipment

[ ] Floor standing equipment

[ ] Hand-held equipment

[X] Other: Door mounting

Module/parts of test item SoC + Antenna

Type BLE

Manufacturer ST + JOHANSON

--

Description --

Type

Manufacturer

Description

File name Issue date

User manual FW Explanation

--

(3) Only for Medical Equipment

Report No: (NIE) 72834RRF.005

Page 5 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Identification of the client
SALTO SYSTEMS, S.L. Arkotz 9, Polígono Lanbarren 20180, Oiartzun, Gipuzkoa, SPAIN

Testing period and place

Test Location Date (start) Date (finish)

DEKRA Testing and Certification S.A.U. 2022-07-07 2022-11-28

Document history

Report number 72834RRF.005

Date 2022-12-21

First release.

Description

Environmental conditions

In the control chamber, the following limits were not exceeded during the test:

Temperature Relative humidity

Min. = 15 ºC Max. = 35 ºC
Min. = 20 % Max. = 75 %

In the semianechoic chamber, the following limits were not exceeded during the test.

Temperature Relative humidity

Min. = 15 ºC Max. = 35 ºC
Min. = 20 % Max. = 75 %

In the chamber for conducted measurements, the following limits were not exceeded during the test:

Temperature Relative humidity

Min. = 15 ºC Max. = 35 ºC
Min. = 20 % Max. = 75 %

Report No: (NIE) 72834RRF.005

Page 6 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Remarks and comments
The tests have been performed by the technical personnel: Alfonso Gutierrez and Francisco Javier Fernandez. Used instrumentation:

Control No. 4825
4826

Equipment

Model

Manufacturer

SEMIANECHOIC ABSORBER FACT 3 200 STP LINED CHAMBER

SHIELDED ROOM

S101

ETS LINDGREN ETS LINDGREN

Next Calibration N/A
N/A

0242 6143 6144 6165 6092 7758

ACTIVE LOOP ANTENNA 9 KHZ-30 MHz

HYBRID BILOG ANTENNA 30MHz-6GHz

PRE-AMPLIFIER 10MHz-6GHz

G>40dB

EMI TEST RECEIVER 9kHz7GHz

DC POWER SUPPLY 30 V / 5 A

11966A 3142E BLNA 0160-01N ESR7 U8002A

DIGITAL MULTIMETER

175

HEWLETT PACKARD
ETS LINDGREN

2024-08-18 2023-10-29

BONN ELEKTRONIK
ROHDE AND SCHWARZ
KEYSIGHT TECHNOLOGIES
FLUKE

2023-03-17 2023-11-08 N/A 2023-11-14

8002

TEMPERATURE CHAMBER

MK 56

BINDER

2023-03-22

6157

SIGNAL AND SPECTRUM FSV40 ANALYZER 10Hz-40GHz

ROHDE AND 2023-10-11 SCHWARZ

Report No: (NIE) 72834RRF.005

Page 7 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Testing verdicts

Fail

F

Inconclusive

I

Not applicable

N/A

Not measured

N/M

Pass

P

Summary

FCC PART 15 PARAGRAPH / RSS-247 Requirement ­ Test case FCC 15.225 (a) / RSS-210 B.6 (a)(i) Field strength of emissions within the band
13.553 MHz -13.567 MHz
FCC 15.225 (b) / RSS-210 B.6 (a)(ii) Field strength of emissions within the band 13.410 - 13.553 MHz and 13.567 ­ 13.710 MHz
FCC 15.225 (c) / RSS-210 B.6 (a)(iii) Field strength of emissions within the band 13.110 - 13.410 MHz and 13.710 ­ 14.010 MHz
FCC 15.225 (d) / RSS-210 B.6 (a)(iv) Field strength of emissions outside of the band 13.110 MHz -14.010 MHz
FCC 15.225 (e) / RSS-210 B.6 (b) Frequency tolerance of the carrier signal
Supplementary information and remarks: None.

Verdict P P P P P

Remark ------

Report No: (NIE) 72834RRF.005

Page 8 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Appendix A: Test results

Report No: (NIE) 72834RRF.005

Page 9 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
INDEX
TEST CONDITIONS ...............................................................................................................................................11 Occupied Bandwidth ...............................................................................................................................................14 FCC 15.225 (a) / RSS-210 B.6 (a). Field strength of emissions within the band 13.553 -13.567 MHz .................15 FCC 15.225 (b) / RSS-210 B.6 (b). Field strength of emissions within the band 13.410 - 13.553 MHz and 13.567 - 13.710 MHz ..........................................................................................................................................................16 FCC 15.225 (c) / RSS-210 B.6 (c). Field strength of emissions within the band 13.110 - 13.410 MHz and 13.710 14.010 MHz.............................................................................................................................................................18 FCC 15.225 (d) / RSS-210 B.6 (a)(iv) Field Strength of Emissions outside of the band 13.110 MHz - 14.010 MHz ................................................................................................................................................................................ 20 FCC 15.225 (e) / RSS-210 B.6 (b) Frequency Tolerance of the Carrier Signal ....................................................23

Report No: (NIE) 72834RRF.005

Page 10 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

(*) Data provided by the Applicant.

TEST CONDITIONS

POWER SUPPLY (*): Vnominal: Vminimum: Vmaximum: Type of Power Supply:

4.5 Vdc 3.825 Vdc 5.175 Vdc 3 x LR03 batteries

ANTENNA (*): Type of Antenna: Maximum Declared Antenna Gain:

Integral, PCB. N/A

TEST FREQUENCY (*): Nominal Operating Frequency: 13.56 MHz

CONDUCTED MEASUREMENTS:
The equipment under test was set up in a shielded room and it is directly connected to the spectrum analyzer.
For frequency stability test the EUT was placed inside a climatic chamber and connected to a frequency meter using a low loss cable. An external DC power supply was connected to the EUT for voltage variation test.

Report No: (NIE) 72834RRF.005

Page 11 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
RADIATED MEASUREMENTS:
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna (Loop antenna for the range between 9 kHz to 30 MHz and Bilog antenna for the range between 30 MHz to 200 MHz) is situated at a distance of 3 m.
For radiated emissions in the range 9 kHz to 30 MHz that is performed at a distance closer than the specified distance, an inverse proportionality factor of 40 dB per decade is used to normalize the measured data for determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation and orientation was varied to find the maximum radiated emission. It was also rotated 360º and in the range between 30 MHz and 200 MHz the antenna height was varied from 1 to 4 meters to find the maximum radiated emission. In the range between 9 kHz and 30 MHz the measurements were made in the three different orientation planes of the loop antenna to determine the maximum received field. In the range between 30 MHz and 200 MHz the measurements were made in both horizontal and vertical planes of polarization.
Radiated measurements setup 9 kHz to 30 MHz:

Report No: (NIE) 72834RRF.005

Page 12 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Radiated measurements setup 30 MHz to 200 MHz:

Report No: (NIE) 72834RRF.005

Page 13 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Occupied Bandwidth
RESULTS:
99 % Occupied Bandwidth and 20 dB Bandwidth.

 NFC mode ISO 14443A:

Operation mode

99% Occupied Bandwidth (kHz)

NFC 13.56 MHz mode ISO 14443A

843.75

20 dB Bandwidth (kHz) 223.73

Verdict: PASS

Report No: (NIE) 72834RRF.005

Page 14 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
FCC 15.225 (a) / RSS-210 B.6 (a). Field strength of emissions within the band 13.553 -13.567 MHz
SPECIFICATION:
The field strength of any emissions within the band 13.553 ­ 13.567 MHz shall not exceed 15,848 microvolts/meter (84 dBµV/m) at 30 meters.

RESULTS: Measurement distance: 3 meters.

 NFC mode ISO 14443A:

The maximum field strength of fundamental emission:

Frequency (MHz) 13.561

Maximum field strength (dBµV/m) measured at 3 m (quasi-peak detector) 62.93

Maximum field strength (dBµV/m) extrapolated to 30 m (40 dB/decade) 22.93

Verdict: PASS

The limit shown in the above plot is extrapolated to 3 meters

Report No: (NIE) 72834RRF.005

Page 15 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
FCC 15.225 (b) / RSS-210 B.6 (b). Field strength of emissions within the band 13.410 - 13.553 MHz and 13.567 - 13.710 MHz

SPECIFICATION:
Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not exceed 334 microvolts/meter (50.47 dBµV/m) at 30 meters.

RESULTS: Measurement distance: 3 meters.
 NFC mode ISO 14443A:

- Band 13.410 - 13.553 MHz

Frequency (MHz) 13.553

Maximum field strength (dBµV/m) measured at 3 m (quasi-peak detector) 48.07

Maximum field strength (dBµV/m) extrapolated to 30 m (40 dB/decade) 8.07

Verdict: PASS

The limit shown in the above plot is extrapolated to 3 meters

Report No: (NIE) 72834RRF.005

Page 16 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
- Band 13.567-13.710 MHz

Frequency (MHz) 13.567

Maximum field strength (dBµV/m) measured at 3 m (quasi-peak detector) 48.98

Maximum field strength (dBµV/m) extrapolated to 30 m (40 dB/decade)
8.98

Verdict: PASS

The limit shown in the above plot is extrapolated to 3 meters

Report No: (NIE) 72834RRF.005

Page 17 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
FCC 15.225 (c) / RSS-210 B.6 (c). Field strength of emissions within the band 13.110 - 13.410 MHz and 13.710 - 14.010 MHz

SPECIFICATION: Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz, the field strength of any emissions shall not exceed 106 microvolts/meter (40.51 dBµV/m) at 30 meters. RESULTS: Measurement distance: 3 meters.
 NFC mode ISO 14443A: - Band 13.110-13.410 MHz

Frequency (MHz) 13.350

Maximum field strength (dBµV/m) measured at 3 m (quasi-peak detector) 40.51

Maximum field strength (dBµV/m) extrapolated to 30 m (40 dB/decade)
0.51

Verdict: PASS

The limit shown in the above plot is extrapolated to 3 meters

Report No: (NIE) 72834RRF.005

Page 18 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
- Band 13.710-14.010 MHz

Frequency (MHz) 13.770

Maximum field strength (dBµV/m) measured at 3 m (quasi-peak detector) 40.54

Maximum field strength (dBµV/m) extrapolated to 30 m (40 dB/decade)
0.54

Verdict: PASS

The limit shown in the above plot is extrapolated to 3 meters

Report No: (NIE) 72834RRF.005

Page 19 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

FCC 15.225 (d) / RSS-210 B.6 (a)(iv) Field Strength of Emissions outside of the band 13.110 MHz - 14.010 MHz

SPECIFICATION:
Field strength of any emissions appearing outside of the band 13.110 MHz - 14.010 MHz band shall not exceed the general radiated emission limits in 15.209/RSS-Gen:

Frequency Range (MHz)
0.009-0.490 0.490-1.705 1.705 - 30.0
30 - 88 88 - 216 216 - 960 Above 960

Field strength (µV/m)
2400/F(kHz) 24000/F(kHz)
30 100 150 200 500

Field strength (dBµV/m) 29.54 40 43.5 46 54

Measurement distance (m)
300 30 30 3 3 3 3

RESULTS:
All tests were performed in a semi-anechoic chamber at a distance of 3 m.
The spectrum was inspected from 9 kHz to 200 MHz searching for spurious signals.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyser. This correction factor includes antenna factor, cable loss and pre-amplifier gain.

Report No: (NIE) 72834RRF.005

Page 20 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
 NFC mode ISO 14443A:
- Frequency range 9 kHz - 30 MHz:
No spurious frequencies were found at less than 20 dB of the limit.

The limits shown in the above plot are extrapolated to 3 meters. The highest peak corresponds to the carrier level.
Resolution bandwidth: 200 Hz for 9 kHz  f  150 kHz 9 kHz for 150 kHz  f  30 MHz

Report No: (NIE) 72834RRF.005

Page 21 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
- Frequency range 30 - 200 MHz:
No spurious frequencies were found at less than 20 dB of the limit.

Verdict: PASS

The above plot shows the results of the scan using peak detector.

Report No: (NIE) 72834RRF.005

Page 22 of 23

2022-12-21

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
FCC 15.225 (e) / RSS-210 B.6 (b) Frequency Tolerance of the Carrier Signal
SPECIFICATION:
The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating frequency over a temperature variation of ­20 degrees to +50 degrees C at normal supply voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For hand carried, battery powered equipment, reduce primary supply voltage to the battery operating end point which shall be specified by the manufacturer.

RESULTS:

Nominal Operating Frequency: 13.56 MHz.

 NFC mode ISO 14443A:

Frequency Stability over Temperature Variations:

Temperature (ºC)
+50 +40 +30 +20 +10
0 -10 -20

Frequency Error (kHz)
0.004500 -0.003000 -0.022500 -0.055500 -0.081000 -0.091500 -0.106500 -0.090000

Frequency Error (%) 0.000033
-0.000022 -0.000166 -0.000409 -0.000597 -0.000675 -0.000785 -0.000664

Frequency Stability over Voltage Variations:

DC Voltage Vmax Vmin

Voltage (V) 5.175 3.825

Temperature (ºC) 20 20

Frequency Error (kHz)
-0.061500 -0.061500

Frequency Error (%) -0.000454 -0.000454

Verdict: PASS

Report No: (NIE) 72834RRF.005

Page 23 of 23

2022-12-21



Related FCC IDs: