Gree Electric Appliances, Inc. of Zhuhai

34

E97068

AUDIX Smart Tsai

Test Report

Huawei Technologies Co.,Ltd Y560-U23 UMTS Mobile Phone QISY560-U23 QISY560U23 y560 u23

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 19 Pages, 325.56KB

Document DEVICE REPORTGetApplicationAttachment.html?id=2668852
FCC TEST REPORT
For
UMTS Mobile Phone Model Number: HUAWEI Y560-U23, Y560-U23
FCC ID: QISY560-U23

Report Number : WT158002028

Test Laboratory
Site Location
Tel Fax Web Email

: Shenzhen Academy of Metrology and Quality Inspection National Digital Electronic Product Testing Center
: No.4 Tongfa Road, Xili Town, Nanshan District, Shenzhen, Guangdong, China
: 0086-755-86928965 : 0086-755-86009898-31396 : www.smq.com.cn : [email protected]

TEST REPORT DECLARATION

Applicant

: Huawei Technologies Co.,Ltd

Address Manufacturer

Administration Building, Headquarters of Huawei : Technologies Co., Ltd., Bantian, Longgang District Shenzhen
China
: Huawei Technologies Co.,Ltd

Address EUT Description

Administration Building, Headquarters of Huawei : Technologies Co., Ltd., Bantian, Longgang District Shenzhen
China
: UMTS Mobile Phone

Model No

: HUAWEI Y560-U23, Y560-U23

Trade mark

: HUAWEI

Serial Number

: 73UBBBB532600464

FCC ID

: QISY560-U23

Test Standards:
FCC Part 15 Subpart B 15.107, 15.109 2014

The EUT described above is tested by Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory to determine the maximum emissions from the EUT. Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory is assumed full responsibility for the accuracy of the test results.

The test report is valid for above tested sample only and shall not be reproduced in part without written approval of the laboratory.

Project Engineer:
Checked by:
Approved by:

(Wan Xiaojing) (Yang Dong Ping)
(Lin Bin)

Date: June.01.2015 Date: June.01.2015 Date: June.01.2015

Report No.: WT158002028

Page 2/19

TABLE OF CONTENTS
TEST REPORT DECLARATION............................................................................................. 2
1. TEST RESULTS SUMMARY ........................................................................................ 4
2. GENERAL INFORMATION .......................................................................................... 5 2.1. Report information.............................................................................................. 5 2.2. Laboratory Accreditation and Relationship to Customer .................................... 5 2.3. Measurement Uncertainty .................................................................................. 5
3. PRODUCT DESCRIPTION ........................................................................................... 6 3.1. EUT Description ................................................................................................. 6 3.2. Block Diagram of EUT Configuration.................................................................. 6 3.3. Operating Condition of EUT ............................................................................... 6 3.4. Support Equipment List ...................................................................................... 7 3.5. Test Conditions .................................................................................................. 8 3.6. Modifications ...................................................................................................... 8
4. TEST EQUIPMENT USED............................................................................................ 9 4.1. Test Equipment Used to Measure Conducted Disturbance................................ 9 4.2. Test Equipment Used to Measure Radiated Disturbance................................... 9
5. CONDUCTED DISTURBANCE TEST ........................................................................ 10 5.1. Test Standard and Limit ................................................................................... 10 5.2. Test Procedure................................................................................................. 10 5.3. Test Arrangement............................................................................................. 10 5.4. Test Data.......................................................................................................... 10
6. RADIATION DISTURBANCE TEST ........................................................................... 14 6.1. Test Standard and Limit ................................................................................... 14 6.2. Test Procedure................................................................................................. 14 6.3. Test Arrangement............................................................................................. 14 6.4. Test Data.......................................................................................................... 14

Report No.: WT158002028

Page 3/19

1. TEST RESULTS SUMMARY

Test Items

Table 1 Test Results Summary FCC Rules

Conducted Disturbance

15.107

Radiation Emission

15.109

Remark: "N/A" means "Not applicable."

Test Results Pass Pass

Report No.: WT158002028

Page 4/19

2. GENERAL INFORMATION

2.1. Report information

2.1.1.This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that SMQ approves recommends or endorses the manufacture, supplier or use of such product/equipment, or that SMQ in any way guarantees the later performance of the product/equipment.

2.1.2.The sample/s mentioned in this report is/are supplied by Applicant, SMQ

therefore

assumes no responsibility for the accuracy of information on the

brand name, model number, origin of manufacture or any information supplied.

2.1.3.Additional copies of the report are available to the Applicant at an additional fee. No third part can obtain a copy of this report through SMQ, unless the applicant has authorized SMQ in writing to do so.

2.2. Laboratory Accreditation and Relationship to Customer
The testing report were performed by the Shenzhen Academy of Metrology and quality Inspection EMC Laboratory (Guangdong EMC compliance testing center), in their facilities located at Bldg. of Metrology & Quality Inspection, Longzhu Road, Nanshan District, Shenzhen, Guangdong, China. At the time of testing, Laboratory is accredited by the following organizations: China National Accreditation Committee for Laboratories (CNAS) accredits the Laboratory for conformance to FCC standards, EMC international standards and EN standards. The Registration Number is L0579.

The Laboratory is listed in the United States of American Federal Communications Commission (FCC), and the registration number are 446246 806614 994606(semi anechoic chamber). The Laboratory is registered to perform emission tests with Industry Canada (IC), and the registration number is IC4174.

TUV Rhineland accredits the Laboratory for conformance to IEC and EN standards, the registration number is E2024086Z02. Measurement Uncertainty
2.3. Measurement Uncertainty
Conducted Emission 9kHz~30MHz 3.5dB

Radiated Emission 30MHz~1000MHz 4.5dB 1GHz~18GHz 4.6dB

Report No.: WT158002028

Page 5/19

3. PRODUCT DESCRIPTION

3.1. EUT Description

Product Type: Hardware Version: Software Version : FCC-ID:

Table 2 Specification of the Equipment under Test HUAWEI Y560-U23, Y560-U23 Ver.A
Y560-U23V100R001C464B005 QISY560-U23

Frequency:

GSM 850: 824-849MHz; PCS 1900: 1850-1910MHz WCDMA Band II: 1850MHz To 1910MHz WCDMA Band V: 824MHz To 849MHz

Type(s) of Modulation: Operating voltage:

GSM/WCDMA: GMSK; 8-PSK; QPSK DC3.8V

Remark: 1. HUAWEI Y560-U23 compared with Y560-U23, only have different model number. All of
the models' circuit theory, electrical design and the key pieces are the same. The differences do not affect the EMC and safety performance. Unless otherwise specified, the model HUAWEI Y560-U23 was chosen as representative model to perform all the tests. 2. Adapters have four kinds of configuration, USA, European, British and Australian respectively. Each configuration just has different plug. The circuit board of European is different with the other three's. And also adapters have four manufacturers. Each manufacturer's adapter has different circuit board.
3.2. Block Diagram of EUT Configuration
Power Supply

PC

EUT

Test mode 1
3.3. Operating Condition of EUT
Test Mode 1: Data transmitter with PC USB port Test Mode 2: Adapter + Earphone + Camera On + Idle Test Mode 3: Adapter + Earphone + Playing + Idle Test Mode 4: Adapter + Earphone + Traffic

Report No.: WT158002028

Page 6/19

The Radiated emission measurements were carried out in semi-anechoic chamber with 3-meter test range, and EUT is rotated on three test planes to find out the worst emission (X plane).
Remark: If there is one kind of accessories with different models, each one should be applied throughout the compliance test respectively, however, only the worst case mode will be recorded in this report. If EUT has more than one typical operation, only the worst test mode will be recorded in this report.

Report No.: WT158002028

Page 7/19

3.4. Support Equipment List

Name Computer Keyboard (USB) Mouse (USB)
Monitor

Model No 9439
SK-8825 (L) MO28UOL 9227-AE1

Adaptor for EUT HW-050100U01

Adaptor for EUT HW-050100E01

Adaptor for EUT HW-050100B01

Adaptor for EUT HW-050100A01

Rechargeable Li-ion for EUT Rechargeable Li-ion for EUT
Data cable
Data cable Earphone Earphone
Earphone Earphone Earphone

HB494590EBC
HB494590EBC
130-41040
H09-000473 HA1-3
1293#+3283# 3.5MM-150
MEMD1532B52 8000
EMC323-011-01 HG-04A

S/N L3BDF2K 02553778 4418011108 V1TDB38 H666LGF4G06262 Y66601F3L00042 P66606F4905716 B66660F3G00256 H667LGF4723178 Y66801F3J00049 P66707F3200350 B66799F4200069
----------
--
--
----
----

3.5. Test Conditions
Date of test May.21, 2015 - May.22, 2015 Date of EUT ReceiveMay.15, 2015 Temperature: 23-26  Relative Humidity: 46-51%
3.6. Modifications
No modification was made.
Report No.: WT158002028

Manufacturer Lenovo Lenovo Lenovo Lenovo
Shen Zhen Huntkey Electronic Co., Ltd. Dongguan City Yingju Electronics Co.,Ltd.
Dongguan Phitek Electronics Co., Ltd. Huizhou BYD Electronic Co., Ltd.
Shen Zhen Huntkey Electronic Co., Ltd. Dongguan City Yingju Electronics Co.,Ltd.
Dongguan Phitek Electronics Co., Ltd. Huizhou BYD Electronic Co., Ltd.
Shen Zhen Huntkey Electronic Co., Ltd. Dongguan City Yingju Electronics Co.,Ltd.
Dongguan Phitek Electronics Co., Ltd. Huizhou BYD Electronic Co., Ltd.
Shen Zhen Huntkey Electronic Co., Ltd. Dongguan City Yingju Electronics Co.,Ltd.
Dongguan Phitek Electronics Co., Ltd. Huizhou BYD Electronic Co., Ltd.
BYD Lithium Battery Company Limited
SCUD (FUJIAN) Electronics Co., Ltd. CHANGSHU HONGLIN TECHNOLOGY CO.,LTD.
SHEN ZHEN PANG NGAI INDUSTRIAL CO., LTD.
GoerTek Inc. BOLUO COUNTY QUANCHENG
ELECTRONIC CO., LTD. Jiangxi Lianchuang Hongsheng
Electronic Co., LTD. MERRY ELECTRONICS CO., LTD.
GoerTek Inc.
Page 8/19

4. TEST EQUIPMENT USED

4.1. Test Equipment Used to Measure Conducted Disturbance

No. SB3319 SB4357
SB3441
SB9054/0 2

Table 2 Conducted Disturbance Test Equipment

Equipment

Manufacturer

Model No.

LAST CALIB

EMI Test Receiver

R&S

ESCS30

Dec.29,2014

AMN

R&S

ENV216

Oct.14,2014

Universal

Communication

R&S

CMU200

Mar.10, 2015

Tester

Wideband Radio

Communication

R&S

CMW500

Oct.27, 2014

Tester

Period 1 Year 1 Year 1 Year
1 Year

4.2. Test Equipment Used to Measure Radiated Disturbance

No. SB3436 SB8501/09 SB5472/02
SB3435
SB3441
SB9054/02

Table 3 Radiated Disturbance Test Equipment

Equipment

Manufacturer

Model No. LAST CALIB

EMI Test Receiver

R&S

ESI26

Dec.29,2014

EMI Test Receiver

R&S

ESU40 Mar.19,2015

Trilog Broadband Antenna(30M-3GHz)

SCHWARZBECK

VULB9163

Jan.19,2015

Double-Ridged

Waveguide Horn

R&S

HF906

Jan.19,2015

Antenna(1G~18GHz)

Universal

Communication

R&S

CMU200 Mar.10, 2015

Tester

Wideband Radio

Communication

R&S

CMW500 Oct.27, 2014

Tester

Period 1 Year 1 Year 1 Year 1 Year
1 Year
1 Year

Report No.: WT158002028

Page 9/19

5. CONDUCTED DISTURBANCE TEST

5.1. Test Standard and Limit

5.1.1.Test Standard

FCC Part 15: Section 15.107

5.1.2.Test Limit

Table 4 Conducted Disturbance Test Limit (Class B)

Frequency

Power Port limits (dBV) Quasi-peak

Average

0.15MHz ~ 0.5MHz

6656*

56~46*

0.5MHz ~ 5 MHz

56

46

5 MHz ~ 30MHz

60

50

* Decreasing linearly with logarithm of the frequency

5.2. Test Procedure

The EUT is put on a table of non-conducting material that is 80cm high. The vertical conducting wall of shielding is located 40cm to the rear of the EUT. The power line of the EUT is connected to the AC mains through a Artificial Mains Network (A.M.N.). A EMI test receiver (R&S Test Receiver ESCS30) is used to test the emissions form both sides of AC line. The bandwidth of EMI test receiver is set at 9kHz.

5.3. Test Arrangement

The arrangement of the equipment is installed to meet the standards and operating in a manner, which tends to maximize its emission characteristics in a normal application. The detailed information refers to test picture.

5.4. Test Data

The emissions don't show in following result tables are more than 20dB below the limits, the test curves are shown in the next page.

Only the worst test result was shown in this report.

Report No.: WT158002028

Page 10/19

Table 5 Conducted Disturbance Test Data at mains Port
Model No.: HUAWEI Y560-U23

Test mode: Data transmitter with PC USB port

Frequency Correction

Quasi-Peak

Average

(MHz)

Factor (dB)

Reading (dBV)

Emission Level (dBV)

Limits (dBV)

Reading (dBV)

Emission Level (dBV)

0.150

9.7

38.2

47.9

66

28.4

38.1

0.198

9.7

38.0

47.7

63.7

32.7

42.4

0.258

9.7

34.0

43.7

61.5

28.2

37.9

Line

0.774

9.8

27.5

37.3

56

25.9

35.7

1.126

9.8

28.9

38.7

56

28.3

38.1

1.306

9.8

27.7

37.5

56

26.3

36.1

0.154

9.7

36.6

46.3

65.8

27.2

36.9

0.198

9.7

38.2

47.9

63.7

32.8

42.5

0.258

9.7

34.0

43.7

61.5

28.2

37.9

Neutral

0.622

9.8

27.2

37.0

56

23.5

33.3

1.126

9.8

29.9

39.7

56

29.1

38.9

1.306

9.8

29.9

39.7

56

28.7

38.5

REMARKS: 1. Emission level(dBuV)=Read Value(dBuV) + Correction Factor(dB)

2. Correction Factor(dB) =LISN Factor (dB) + Cable Factor (dB)+Limiter Factor(dB)

3. The other emission levels were are more than 20dB below the limits.

Limits (dBV)
56 53.7 51.5 46 46 46 55.8 53.7 51.5 46 46 46

Report No.: WT158002028

Page 11/19

Conducted Disturbance

EUT: Op Cond: Test Spec: Comment:

HUAWEI Y560-U23 Data trasmiting with PC USB port L AC 120V/60Hz

dBuV 70

Mkr : 150.00 kHz 58.1 dBuV

60

50

40

30

20

10

0

0.15

1

CONAPA ConAVB

10

30

MHz

Report No.: WT158002028

Page 12/19

Conducted Disturbance

EUT: Op Cond: Test Spec: Comment:

HUAWEI Y560-U23 Data trasmiting with PC USB port N AC 120V/60Hz

dBuV 70

Mkr : 154.00 kHz 53.1 dBuV

60

50

40

30

20

10

0

0.15

1

CONAPA ConAVB

10

30

MHz

Report No.: WT158002028

Page 13/19

6. RADIATION DISTURBANCE TEST
6.1. Test Standard and Limit
6.1.1.Test Standard FCC Part 15: Section 15.109
6.1.2.Test Limit Table 7 Radiation Disturbance Test Limit for FCC (Class B)

* The lower limit shall apply at the transition frequency. * The test distance is 3m.
6.2. Test Procedure
The EUT is placed on a turntable, which is 0.8 meter above ground. The turntable can rotate 360 degrees to determine the position of the maximum emission level. EUT is set 3 meters away from the receiving antenna, which is mounted on an antenna tower. The antenna can move up and down between 1 to 4 meters to find out the maximum emission level. Broadband antenna is used as a receiving antenna. Both horizontal and vertical polarization of the antenna is set on test. Set RBW=100 kHz for f < 1 GHz; VBW >= RBW; Detector function = peak; Set RBW = 1 MHz, VBW= 3MHz for f > 1 GHz for peak measurement.
6.3. Test Arrangement
The arrangement of the equipment is installed to meet the standards and operating in a manner, which tends to maximize its emission characteristics in a normal application. The detailed information refers to test picture.
6.4. Test Data
The emissions don't show in following result tables are more than 20dB below the limits, the test curves are shown in the next page. The low frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit line per 15.31(o) was not reported.
Only the worst test result was shown in this report.

Report No.: WT158002028

Page 14/19

Table 8 Radiated Disturbance Test Data

Frequency Cable Loss Antenna

MHz +pre amp Factor

(dB)

(dB)

Readings (dBV/m)

Level (dBV/m)

Polarity (H/V)

Turntable Angle (deg)

Antenna Height (cm)

51.240

0.8

55.886

0.9

13.3

12.6

26.7

H

13.0

6.8

20.7

H

70

100

0

100

59.390

0.9

13.0

7.1

21.0

H

20

100

90.756

1.2

11.9

3.6

16.7

H

0

100

387.260

2.4

14.6

5.6

22.6

H

120 100

900.120

3.9

21.1

2.6

27.6

H

80

100

43.260

0.7

13.6

6.6

20.9

V

60

100

51.360

0.8

13.3

13.5

27.6

V

50

100

51.920

0.8

13.3

16.5

30.6

V

40

100

53.183

0.7

13.3

13.6

27.6

V

20

100

54.340

0.8

13.3

7.9

22.0

V

0

100

580.986

3.0

16.6

5.3

24.9

V

0

100

PK

1198.960 -41.0

24.4

66.4

49.8

H

0

100

1398.960 -40.8

24.3

66.6

50.1

H

20

100

2391.260 -40.2

28.3

61.7

49.8

H

0

100

2661.026 -39.6

29.6

57.8

47.8

H

0

100

3193.286 -39.0

30.4

55.5

46.9

H

0

100

4456.201 -39.2

33.7

54.2

48.7

H

20

100

1197.490 -41.0

24.4

65.5

48.9

V

0

100

1398.260 -40.8

24.3

63.4

46.9

V

10

100

1713.496 -40.5

26.7

57.4

43.6

V

0

100

3192.280 -39.0

30.4

54.3

45.7

V

70

100

4439.782 5994.926

-39.3 -38.2

33.7

52.4

46.8

V

34.2

51.8

47.8

V

60

100

50

100

AV

1198.960 -41.0

24.4

49.2

32.6

H

0

100

1398.960 -40.8

24.3

50.1

33.6

H

20

100

2391.260 -40.2

28.3

44.7

32.8

H

0

100

2661.026 -39.6

29.6

39.7

29.7

H

0

100

3193.286 -39.0

30.4

37.5

28.9

H

0

100

4456.201 -39.2

33.7

36.1

30.6

H

20

100

1197.490 -41.0

24.4

46.3

29.7

V

0

100

1398.260 -40.8

24.3

45.0

28.5

V

10

100

1713.496 3192.280 4439.782

-40.5 -39.0 -39.3

26.7

40.3

26.5

V

30.4

39.3

30.7

V

33.7

35.8

30.2

V

0

100

70

100

60

100

5994.926 -38.2

34.2

35.2

31.2

V

50

100

Limits Margin (dBV/m) (dB)

40.0 13.3

40.0 19.3

40.0 19.0

43.5 26.8

46.0 23.4

46.0 18.4

40.0 19.1

40.0 12.4

40.0

9.4

40.0 12.4

40.0 18.0

46.0 21.1

74

24.2

74

23.9

74

24.2

74

26.2

74

27.1

74

25.3

74

25.1

74

27.1

74

30.4

74

28.3

74

27.2

74

26.2

54

21.4

54

20.4

54

21.2

54

24.3

54

25.1

54

23.4

54

24.3

54

25.5

54

27.5

54

23.3

54

23.8

54

22.8

Report No.: WT158002028

Page 15/19

Radiated Emission

EUT Information
EUT Model name: Operater Mode: Comment:

HUAWEI Y560-U23 Data transmitter with PC USB port

Common Information
Test Description: Customer Antenna Position: Operator Name: Comment1: Comment2:

SMQ NETC EMC Lab.3m Chamber Horizontal AC 120V/60Hz

Field strength 30M-1GHz 1F 3m chamber

Level in dBV/

70 65 60 55 50 45 40 35 30 25 20 15 10
5 0 30M

FCC Part 15 B F QP

50 60

80 100M

200

300 400 500

Frequency in Hz

800 1G

Report No.: WT158002028

Page 16/19

Radiated Emission

EUT Information
EUT Model name: Operater Mode: Comment:

HUAWEI Y560-U23 Data transmitter with PC USB port

Common Information
Test Description: Customer Antenna Position: Operator Name: Comment1: Comment2:

SMQ NETC EMC Lab.3m Chamber Vertical AC 120V/60Hz

Field strength 30M-1GHz 1F 3m chamber

Level in dBV/

70 65 60 55 50 45 40 35 30 25 20 15 10
5 0 30M

FCC Part 15 B F QP

50 60

80 100M

200

300 400 500

Frequency in Hz

800 1G

Report No.: WT158002028

Page 17/19

Radiated Emission

EUT Information
EUT Model name: Operater Mode: Comment:

HUAWEI Y560-U23 Data transmitter with PC USB port

Common Information
Test Description: Customer Antenna Position: Operator Name: Comment1: Comment2:

SMQ NETC EMC Lab.3m Chamber Horizontal AC 120V/60Hz

Field strength 1-6GHz 1F 3m chamber

Level in dBV/

80 75 70 65 60 55 50 45 40 35 30 25 20
1G

FCC Part 15 B F PK FCC Part 15 B F AV

2G

3G

Frequency in Hz

4G

5G

6G

Report No.: WT158002028

Page 18/19

Radiated Emission

EUT Information
EUT Model name: Operater Mode: Comment:

HUAWEI Y560-U23 Data transmitter with PC USB port

Common Information
Test Description: Customer Antenna Position: Operator Name: Comment1: Comment2:

SMQ NETC EMC Lab.3m Chamber Vertical AC 120V/60Hz

Field strength 1-6GHz 1F 3m chamber

Level in dBV/

80 75 70 65 60 55 50 45 40 35 30 25 20
1G

FCC Part 15 B F PK FCC Part 15 B F AV

2G

3G

Frequency in Hz

4G

5G

6G

Report No.: WT158002028

Page 19/19



Related FCC IDs:

Search Any Device: