CE

philo zhong

RF Exposure Info

Dongguan Huaxun Plastic Technology Co., Ltd. W007B RV door lock 2BPTI-W007B 2BPTIW007B w007b

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 7 Pages, 386.89KB

Document DEVICE REPORTGetApplicationAttachment.html?id=8362922
TEST REPORT

Reference No. .................... : WTD25D05124155W002 FCC ID ................................ : 2BPTI-W007B Applicant ............................ : Dongguan Huaxun Plastic Technology Co., Ltd. Address .............................. : Room 302, Building 1, No. 16 Fumin Road, Tangli, Fenggang Town,
Dongguan City, Guangdong Province, China Manufacturer .................... : Dongguan Huaxun Plastic Technology Co., Ltd. Address .............................. : Room 302, Building 1, No. 16 Fumin Road, Tangli, Fenggang Town,
Dongguan City, Guangdong Province, China Product............................... : RV door lock Model(s). ............................ : W007B Standards........................... : FCC 47CFR Part 2 Subpart J Section 2.1093 Date of Receipt sample .... : 2025-05-22 Date of Test........................ : 2025-05-23 to 2025-06-03 Date of Issue...................... : 2025-06-04 Test Result ......................... : Pass

Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver.
Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China
Tel: +86-769-2267 6998 Fax: +86-769-2267 6828

Compiled by:

Approved by:

Estel Qian / Project Engineer

Deval Qin / Designated Reviewer

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

Page 1 of 7

Reference No.: WTD25D05124155W002

Page 2 of 7

2. Contents
Page
1 COVER PAGE...........................................................................................................................................1
2. CONTENTS ...............................................................................................................................................2
3. REVISION HISTORY.................................................................................................................................3
4. GENERAL INFORMATION.......................................................................................................................4
4.1. GENERAL DESCRIPTION OF E.U.T. ..................................................................................................4 4.2. DETAILS OF E.U.T. .........................................................................................................................4 4.3. TEST FACILITY ................................................................................................................................4 4.4. SUBCONTRACTED ...........................................................................................................................4 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 4
5. TEST SUMMARY ......................................................................................................................................5
6. RF EXPOSURE .........................................................................................................................................6
6.1. PROCEDURES AND REQUIREMENTS .................................................................................................6 6.2. MPE CALCULATION METHOD...........................................................................................................6 6.3. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION...................................................................6

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

Reference No.: WTD25D05124155W002

Page 3 of 7

3. Revision History

Test Report No.

Date of Receipt Sample

Date of Test

Date of Issue

Purpose

2025-05-23

WTD25D05124155W002 2025-05-22

to

2025-06-04

2025-06-03

Original

Comment -

Approved Valid

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

Reference No.: WTD25D05124155W002

Page 4 of 7

4. General Information
4.1. General Description of E.U.T.

Product Name: Model No.: Model Description: Hardware Version: Software Version:

RV door lock W007B N/A MJ-W007B-M-V1.0 MJ-W007B-202503221548

4.2. Details of E.U.T.

Frequency Range:

315MHz

Type of Modulation:

ASK

Antenna installation:

PCB Antenna

Antenna Gain

-1.0dBi

Note:

#: The antenna gain is provided by the applicant, and the applicant should be responsible for its authenticity, WALTEK lab has not verified the authenticity of its information.

Battery:

DC 3V from CR2032 battery

4.3. Test Facility

The test facility has a test site registered with the following organizations: ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A. Waltek Testing Group Co., Ltd. Has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration number 7760A, October 15, 2016. FCC Designation No.: CN1201. Test Firm Registration No.: 523476. Waltek Testing Group Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration number 523476, September 10, 2019.

4.4. Subcontracted

Whether parts of tests for the product have been subcontracted to other labs:

Yes

No

If Yes, list the related test items and lab information:

Test Lab: N/A

Lab address: N/A

Test items: N/A

4.5. Abnormalities from Standard Conditions
None.

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

Reference No.: WTD25D05124155W002

Page 5 of 7

5. Test Summary
Test Items Maximum Permissible Exposure (Exposure of Humans to RF Fields)

Test Requirement FCC Part 2.1093

Result PASS

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

Reference No.: WTD25D05124155W002

Page 6 of 7

6. RF Exposure
Test Requirement: Evaluation Method:

FCC 47CFR Part 2 Subpart J Section 2.1093 FCC 47CFR Part 1 Subpart I Section 1.1307, KDB 447498 D01 General RF Exposure Guidance v06

6.1. Procedures and Requirements

According to §15.247 (i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission's guidelines.
For 100 MHz to 6 GHz and test separation distances  50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)]  3.0 for 1-g SAR, and  7.5 for 10-g extremity SAR, where  f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison
When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion.
Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to qualify for TCB approval.

6.2. MPE Calculation Method

Result =P F / D P= Maximum turn-up power in mW F= Channel frequency in GHz D= Minimum test separation distance in mm
6.3. Radio Frequency Radiation Exposure Evaluation
According to ANSI C63.10:2013 clause 9.5

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

Reference No.: WTD25D05124155W002

Page 7 of 7

Frequency(MHz) 315

E-Field Strength (dBuV/m)
81.03

Measurement Distance (m)
3

EIRP (dBm) -14.17

A distance of 5mm normally can be maintained between the user and the device.

Frequency (GHz)

Antenna Antenna

Gain

Gain

(dBi) (numeric)

Max Power (dBm)

Max Tune-up Power

Max Tune-up Power

Distance

(dBm)

(mW)

(mm)

Result

0.315

-1.0

0.79

-13.17

-12.17

0.060674

5

0.006811

Note: 1. EIRP = ERP + 2.15. 2. Chose the maximum power to do MPE analysis.

Limit 3

Conclusion: No SAR measurement is required.

======End of Report======

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn

