RDG180807019-00A WiFi Report
SONOFF TH10&TH16 FCC Part 15C Test Report
TH10/16-DOC Temp & Humi Monitoring Smart Switch - SONOFF Official
Visit
Sonoff.tech Download analytic data › Show:
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 46 Pages, 877.06KB
Document DEVICE REPORT
✖
FCC PART 15.247 TEST REPORT For Shenzhen Sonoff Technologies Co., Ltd. Building 8, Room 1001, Lianhua industrial park, Longyuan Road, Hualian community, Longhua St, Longhua dist, Shenzhen, Guangdong, China. FCC ID: 2APN5TH1016 Report Type: Original Report Product Name: WiFi Smart Switch Report Number: RDG180807019-00A Report Date: 2018-08-22 Jerry Zhang Reviewed By: Test Laboratory: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk "*". Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4 OBJECTIVE ...................................................................................................................................................................4 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................4 TEST METHODOLOGY ..................................................................................................................................................4 MEASUREMENT UNCERTAINTY....................................................................................................................................5 TEST FACILITY.............................................................................................................................................................5 SYSTEM TEST CONFIGURATION..........................................................................................................................6 DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6 EUT EXERCISE SOFTWARE ..........................................................................................................................................6 EQUIPMENT MODIFICATIONS .......................................................................................................................................8 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................8 SUPPORT CABLE LIST AND DETAILS ............................................................................................................................8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................9 SUMMARY OF TEST RESULTS .............................................................................................................................10 FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE).......................................11 APPLICABLE STANDARD ............................................................................................................................................11 FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................12 APPLICABLE STANDARD ............................................................................................................................................12 ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................................12 FCC §15.207 (a) AC LINE CONDUCTED EMISSIONS .....................................................................................13 APPLICABLE STANDARD ............................................................................................................................................13 EUT SETUP ................................................................................................................................................................13 EMI TEST RECEIVER SETUP.......................................................................................................................................13 TEST PROCEDURE ......................................................................................................................................................14 CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................14 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................14 TEST DATA ................................................................................................................................................................15 FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS.............................................................................17 APPLICABLE STANDARD ............................................................................................................................................17 EUT SETUP ................................................................................................................................................................17 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................18 TEST PROCEDURE ......................................................................................................................................................18 CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................19 TEST DATA ................................................................................................................................................................19 FCC §15.247(a) (2)6 dB EMISSION BANDWIDTH..............................................................................................27 APPLICABLE STANDARD ............................................................................................................................................27 TEST PROCEDURE ......................................................................................................................................................27 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................27 TEST DATA ................................................................................................................................................................28 FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER......................................................34 APPLICABLE STANDARD ............................................................................................................................................34 TEST PROCEDURE ......................................................................................................................................................34 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................34 Page 2 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A TEST DATA ................................................................................................................................................................35 FCC §15.247(d) 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE........................................................36 APPLICABLE STANDARD ............................................................................................................................................36 TEST PROCEDURE ......................................................................................................................................................36 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................36 TEST DATA ................................................................................................................................................................37 FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................41 APPLICABLE STANDARD ............................................................................................................................................41 TEST PROCEDURE ......................................................................................................................................................41 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................41 TEST DATA ................................................................................................................................................................41 Page 3 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A GENERAL INFORMATION Product Description for Equipment under Test (EUT) EUT Name: EUT Model: Multiple Model: FCC ID: Rated Input Voltage: External Dimension: Serial Number: EUT Received Date: WiFi Smart Switch TH16 TH10 2APN5TH1016 100~240Vac 144mm(L)*51 mm(W)*32 mm(H) 180807019 2018.08.10 Note: The series product, model TH16, TH10 are electrically identical. For marketing purpose, we selected TH16 for fully test. The differences between them are explained in the declaration letter. Objective This report is prepared on behalf of Shenzhen Sonoff Technologies Co., Ltd. in accordance with Part 2, Subpart J, Part 15, Subparts A and C of the Federal Communications Commission's rules. The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15Subpart C, section 15.203, 15.205, 15.207, 15.209 and 15.247 rules. Related Submittal(s)/Grant(s) N/A Test Methodology All measurements contained in this report were conducted with ANSI C63.10-2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. And KDB 558074 D01 DTS Meas Guidance v04. All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan). Page 4 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Measurement Uncertainty Parameter Occupied Channel Bandwidth RF output power, conducted Power Spectral Density, conducted Unwanted Emissions, radiated Unwanted Emissions, conducted Temperature Humidity DC and low frequency voltages Duty Cycle AC Power Lines Conducted Emission Measurement Uncertainty ±5 % ±0.61dB ±0.61 dB 30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB, 6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB ±1.5 dB ±1 ±5% ±0.4% 1% 3.12 dB (150 kHz to 30 MHz) Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China. The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220. The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D. Page 5 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A SYSTEM TEST CONFIGURATION Description of Test Configuration The system was configured for testing in Engineering Mode, which was provided by the manufacturer. For 2.4GHz band, total 11 channels are provided: Channel 1 2 3 4 5 6 Frequency (MHz) 2412 2417 2422 2427 2432 2437 Channel 7 8 9 10 11 / Frequency (MHz) 2442 2447 2452 2457 2462 / For 802.11b, 802.11g, and 802.11n ht20 modes were test with channel 1,6,11. The worst-case data rates are determined to be as follows for each mode based upon investigations by measuring the average power and PSD across all data rates bandwidths, and modulations. EUT Exercise Software The software "SecureCRT.exe" was used for testing, which was provided by manufacturer. The maximum power was configured as below table, that provided by the manufacturer: Mode 802.11b 802.11g 802.11n ht20 Channel Low Middle High Low Middle High Low Middle High Frequency (MHz) 2412 2437 2462 2412 2437 2462 2412 2437 2462 Data Rate 1 Mbps 1 Mbps 1 Mbps 6 Mbps 6 Mbps 6 Mbps MCS0 MCS0 MCS0 Power level Setting 8 11 14 11 14 16 11 14 16 The maximum duty cycle as following table: Test mode 802.11b 802.11g 802.11n ht20 Ton (ms) 4.287 0.713 0.673 Ton+off (ms) 4.736 0.793 0.769 Duty Cycle (%) 90.5 89.9 87.5 Page 6 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A DELTA MARKER 2 4.735641026 ms Ref 30 dBm 30 Offset 0.5 dB 20 1 PK * CLRWR 10 * Att 40 dB 802.11b RBW 10 MHz * VBW 10 MHz SWT 20 ms 0 1 12 -10 -20 -30 -40 -50 -60 -70 Center 2.437 GHz 2 ms/ Delta 2 [T1 ] 0.05 dB 4.735641 ms Marker 1 [T1 ] -6.25 dBm 5.480769 ms A Delta 1 [T1 ] SGL -0.05 dB 4.286923 ms LVL 3DB Date: 15.AUG.2018 13:29:15 DELTA MARKER 2 793.2692308 µs Ref 30 dBm 30 Offset 0.5 dB 20 1 PK * CLRWR 10 * Att 40 dB 802.11g RBW 10 MHz * VBW 10 MHz SWT 5 ms 0 1 12 -10 -20 -30 -40 -50 -60 -70 Center 2.437 GHz 500 µs/ Delta 2 [T1 ] 0.31 dB 793.269231 µs Marker 1 [T1 ] -8.12 dBm 2.304872 ms A Delta 1 [T1 ] SGL 0.13 dB 713.141026 µs LVL 3DB Date: 15.AUG.2018 13:37:18 Page 7 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A DELTA MARKER 2 769.2307692 µs Ref 30 dBm 30 Offset 0.5 dB 20 1 PK * CLRWR 10 802.11n ht20 * Att 40 dB RBW 10 MHz * VBW 10 MHz SWT 5 ms 0 1 12 -10 -20 -30 -40 -50 -60 -70 Center 2.437 GHz 500 µs/ Delta 2 [T1 ] 0.11 dB 769.230769 µs Marker 1 [T1 ] -7.61 dBm 1.984359 ms A Delta 1 [T1 ] SGL 0.08 dB 673.076923 µs LVL 3DB Date: 15.AUG.2018 13:37:54 Equipment Modifications No modification was made to the EUT. Local Support Equipment List and Details Manufacturer unknown Description Resistive load Model 25 Ou Support Cable List and Details Cable Description Power Cable Shielding Type no Ferrite Core no Length (m) 1.0 Serial Number / From EUT To Load Page 8 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Block Diagram of Test Setup Report No.: RDG180807019-00A Page 9 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) SUMMARY OF TEST RESULTS Report No.: RDG180807019-00A FCC Rules FCC §15.247 (i) & §1.1310 & §2.1091 §15.203 §15.207 (a) §15.205, §15.209, §15.247(d) §15.247 (a)(2) §15.247(b)(3) §15.247(d) §15.247(e) Description of Test Maximum Permissible Exposure (MPE) Antenna Requirement AC Line Conducted Emissions Spurious Emissions 6 dB Bandwidth Maximum Conducted Output Power 100 kHz Bandwidth of Frequency Band Edge Power Spectral Density Result Compliance Compliance Compliance Compliance Compliance Compliance Compliance Compliance Page 10 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) Applicable Standard According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission's guidelines. Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091) Frequency Range (MHz) 0.31.34 1.3430 30300 3001500 1500100,000 (B) Limits for General Population/Uncontrolled Exposure Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm2) 614 1.63 *(100) 824/f 2.19/f *(180/f²) 27.5 0.073 0.2 / / f/1500 / / 1.0 Averaging Time (minutes) 30 30 30 30 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to §1.1310 and §2.1091 RF exposure is calculated. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4R² = power density (in appropriate units, e.g. mW/cm2); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: Frequency (MHz) 2412-2462 Antenna Gain (dBi) (numeric) 1 1.26 Conducted output power including Tuneup Tolerance (dBm) (mW) 22 158.49 Evaluation Distance (cm) 20.00 Power Density (mW/cm2) MPE Limit (mW/cm2) 0.04 1.0 Result: The device meet FCC MPE at 20 cm distance Page 11 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.203 - ANTENNA REQUIREMENT Applicable Standard According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector is prohibited. The structure and application of the EUT were analyzed to determine compliance with section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria: a. Antenna must be permanently attached to the unit. b. Antenna must use a unique type of connector to attach to the EUT. c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct antenna is employed with the unit. Antenna Connector Construction The EUT has one internal antenna arrangement for WIFI, and the antenna gain is 1dBi, fulfill the requirement of this section. Please refer to the EUT photos. Result: Compliance. Page 12 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.207 (a) AC LINE CONDUCTED EMISSIONS Applicable Standard FCC§15.207(a) EUT Setup The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification used was with the FCC Part 15.207. The spacing between the peripherals was 10 cm. The EUT was connected to the main lisn with a 120 V/60 Hz AC power source. EMI Test Receiver Setup The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz. During the conducted emission test, the EMI test receiver was set with the following configurations: Frequency Range 150 kHz 30 MHz IF B/W 9 kHz Page 13 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Test Procedure During the conducted emission test, the adapter was connected to the first LISN. Maximizing procedure was performed on the six (6) highest emissions of the EUT. All data was recorded in the Quasi-peak and average detection mode. Corrected Amplitude & Margin Calculation The basic equation is as follows: VC = VR + AC + VDF Cf = AC + VDF Herein, VC (cord. Reading): corrected voltage amplitude VR: reading voltage amplitude Ac: attenuation caused by cable loss VDF: voltage division factor of AMN Cf: Correction Factor The "Margin" column of the following data tables indicates the degree of compliance within the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit Corrected Amplitude Test Equipment List and Details Manufacturer R&S R&S R&S Unknown R&S Description EMI Test Receiver L.I.S.N Two-line V-network Coaxial Cable Test Software Model ESCS 30 ESH2-Z5 ENV 216 C-NJNJ-50 EMC32 Serial Number 830245/006 892107/021 101614 C-0200-01 Version8.53.0 Calibration Date 2017-12-11 2017-09-25 2017-12-08 2017-09-05 N/A Calibration Due Date 2018-12-11 2018-09-25 2018-12-08 2018-09-05 N/A * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Page 14 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: 28.6 C 56 % 99.6 kPa The testing was performed by Alex You on 2018-08-13. Test Mode: Transmitting AC120 V, 60 Hz, Line: Report No.: RDG180807019-00A Level in dB 80 70 60 50 40 30 20 10 0 150k Quasi-Peak Limit Average Limit 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Frequency (MHz) 0.177322 0.307284 0.491712 1.239175 1.259081 3.049107 Frequency (MHz) 0.472507 0.491712 1.190776 1.259081 2.579298 3.049107 QuasiPeak (dBV) 41.5 31.2 35.9 34.3 34.1 32.8 Average (dBV) 27.4 34.2 26.9 28.2 23.9 28.1 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line Corr. (dB) Margin (dB) L1 10.8 23.1 L1 10.1 28.8 L1 9.9 20.2 L1 9.8 21.7 L1 9.8 21.9 L1 9.8 23.2 Limit (dBV) 64.6 60.0 56.1 56.0 56.0 56.0 Comment Compliance Compliance Compliance Compliance Compliance Compliance Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line Corr. (dB) Margin (dB) L1 9.9 19.1 L1 9.9 11.9 L1 9.8 19.1 L1 9.8 17.8 L1 9.8 22.1 L1 9.8 17.9 Limit (dBV) 46.5 46.1 46.0 46.0 46.0 46.0 Comment Compliance Compliance Compliance Compliance Compliance Compliance Page 15 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) AC120 V, 60 Hz, Neutral: Report No.: RDG180807019-00A Level in dB 80 70 60 50 40 30 20 10 0 150k Quasi-Peak Limit Average Limit 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Frequency (MHz) 0.161152 0.255827 0.390261 0.491712 1.209904 1.259081 Frequency (MHz) 0.167702 0.390261 0.491712 1.209904 1.259081 3.049107 QuasiPeak (dBV) 42.1 34.7 26.8 32.6 32.9 34.1 Average (dBV) 28.5 20.6 29.9 26.2 27.0 24.2 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line Corr. (dB) Margin (dB) N 11.0 23.3 N 10.3 26.9 N 10.0 31.2 N 9.9 23.5 N 9.8 23.1 N 9.8 21.9 Limit (dBV) 65.4 61.6 58.1 56.1 56.0 56.0 Comment Compliance Compliance Compliance Compliance Compliance Compliance Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line Corr. (dB) Margin (dB) N 10.9 26.5 N 10.0 27.5 N 9.9 16.2 N 9.8 19.8 N 9.8 19.0 N 9.8 21.8 Limit (dBV) 55.1 48.1 46.1 46.0 46.0 46.0 Comment Compliance Compliance Compliance Compliance Compliance Compliance Page 16 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS Applicable Standard FCC §15.247 (d); §15.209; §15.205; EUT Setup Below 1GHz: Above 1GHz: The radiated emission Below 1GHz tests were performed in the 3 meters chamber test site A, above 1GHz tests were performed in the 3 meters chamber test site B, using the setup accordance with the ANSI C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits. The spacing between the peripherals was 10 cm. Page 17 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A EMI Test Receiver & Spectrum Analyzer Setup The system was investigated from 30 MHz to 25 GHz. During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the following configurations: 30MHz-1000MHz: Measurement QP RBW 120 kHz Video B/W 300 kHz IF B/W 120kHz 1GHz- 25GHz: Measurement PK AV Note: T is minimum transmission duration Duty cycle Any >98% <98% RBW 1MHz 1MHz 1MHz Video B/W 3 MHz 10 Hz 1/T Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and Average detection modes for frequencies above 1 GHz. Corrected Amplitude & Margin Calculation The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the Amplifier Gain from the Meter Reading. The basic equation is as follows: Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain The "Margin" column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit Corrected Amplitude Page 18 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Test Equipment List and Details Manufacturer R&S Sunol Sciences HP Agilent ETS-Lindgren MITEQ Quinstar Ducommun Technolagies E-Microwave Micro-tronics Unknown Unknown Unknown Unknown Unknown Farad Description Model EMI Test Receiver Antenna Amplifier Spectrum Analyzer Horn Antenna Amplifier Amplifier ESCI JB3 8447D E4440A 3115 AFS42-0010180025-S-42 QLW-18405536-JO Horn Antenna Band-stop Filters High Pass Filter Coaxial Cable Coaxial Cable Coaxial Cable Coaxial Cable Coaxial Cable Test Software ARH-4223-02 OBSF-2400-2483.5S HPM50111 C-NJNJ-50 C-NJNJ-50 C-NJNJ-50 C-SJSJ-50 C-2.4J2.4J-50 EZ-EMC Serial Number 100224 A060611-1 2727A05902 SG43360054 000 527 35 2001271 15964001001 1007726-01 1304 OE01601525 S/N-G217 C-0400-01 C-0075-01 C-1000-01 C-0800-01 C-0700-02 V1.1.4.2 Calibration Date 2017-12-11 2017-11-10 2017-09-05 2018-01-04 2016-01-05 Calibration Due Date 2018-12-11 2020-11-10 2018-09-05 2019-01-04 2019-01-04 2017-09-05 2018-09-05 2018-06-27 2019-06-27 2016-11-18 2019-11-18 2018-06-16 2018-06-16 2017-09-05 2017-09-05 2017-09-05 2017-09-05 2018-06-27 N/A 2019-06-16 2019-06-16 2018-09-05 2018-09-05 2018-09-05 2018-09-05 2019-06-27 N/A * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: 26.9~27.6 C 38~59 % 99.4~99.9 kPa * The testing was performed by Blake Yang, Sunny Cen on 2018-08-16, 2018-08-17. Test Result: Compliance, please Refer to the following data Test Mode: Transmitting Page 19 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) 1) 30MHz-1GHz(802.11n ht20 Low channel was the worst) Horizontal: Report No.: RDG180807019-00A Frequency (MHz) 30.0000 124.0900 184.2300 239.5200 254.0700 320.0300 Receiver Reading (dBuV) 25.55 26.25 34.11 31.39 34.62 37.83 Detector QP QP QP QP QP QP Correction Factor (dB/m) 1.55 -4.75 -7.61 -6.09 -6.12 -3.63 Cord. Amp. (dBuV/m) 27.10 21.50 26.50 25.30 28.50 34.20 Limit (dBuV/m) 40.00 43.50 43.50 46.00 46.00 46.00 Margin (dB) 12.90 22.00 17.00 20.70 17.50 11.80 Page 20 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Vertical: Report No.: RDG180807019-00A Frequency (MHz) 30.0000 42.6100 52.3100 130.8800 229.8200 373.3800 Receiver Reading (dBuV) 28.65 37.10 39.02 32.48 30.17 30.20 Detector QP QP QP QP QP QP Correction Factor (dB/m) 1.55 -7.70 -11.92 -4.98 -6.57 -2.70 Cord. Amp. (dBuV/m) 30.20 29.40 27.10 27.50 23.60 27.50 Limit (dBuV/m) 40.00 40.00 40.00 43.50 46.00 46.00 Margin (dB) 9.80 10.60 12.90 16.00 22.40 18.50 Page 21 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 2) 1-25GHz: 802.11b Mode: Frequency (MHz) Receiver Reading (dBV) Detector 2412.00 64.31 PK 2412.00 61.26 AV 2412.00 65.85 PK 2412.00 62.44 AV 2390.00 25.42 PK 2390.00 13.85 AV 4824.00 57.48 PK 4824.00 54.18 AV 7236.00 45.39 PK 7236.00 32.99 AV 2437.00 63.54 PK 2437.00 60.18 AV 2437.00 65.03 PK 2437.00 61.98 AV 4874.00 57.18 PK 4874.00 53.93 AV 7311.00 45.41 PK 7311.00 32.84 AV 2462.00 62.87 PK 2462.00 59.71 AV 2462.00 64.62 PK 2462.00 61.67 AV 2483.50 26.06 PK 2483.50 14.31 AV 4924.00 56.56 PK 4924.00 52.77 AV 7386.00 45.29 PK 7386.00 32.17 AV Rx Antenna Polar Factor (H/V) (dB/m) Cable loss (dB) Amplifier Gain (dB) Low Channel: 2412 MHz H 28.12 1.81 0.00 H 28.12 1.81 0.00 V 28.12 1.81 0.00 V 28.12 1.81 0.00 V 28.08 1.80 0.00 V 28.08 1.80 0.00 V 32.95 3.19 37.20 V 32.95 3.19 37.20 V 35.81 4.77 37.27 V 35.81 4.77 37.27 Middle Channel: 2437 MHz H 28.17 1.82 0.00 H 28.17 1.82 0.00 V 28.17 1.82 0.00 V 28.17 1.82 0.00 V 33.05 3.26 37.21 V 33.05 3.26 37.21 V 36.01 4.64 37.36 V 36.01 4.64 37.36 High Channel: 2462 MHz H 28.22 1.83 0.00 H 28.22 1.83 0.00 V 28.22 1.83 0.00 V 28.22 1.83 0.00 V 28.27 1.84 0.00 V 28.27 1.84 0.00 V 33.15 3.27 37.22 V 33.15 3.27 37.22 V 36.20 4.51 37.46 V 36.20 4.51 37.46 Corrected Amplitude (dBV/m) 94.24 91.19 95.78 92.37 55.30 43.73 56.42 53.12 48.70 36.30 93.53 90.17 95.02 91.97 56.28 53.03 48.70 36.13 92.92 89.76 94.67 91.72 56.17 44.42 55.76 51.97 48.54 35.42 Limit (dBV/m) N/A N/A N/A N/A 74.00 54.00 74.00 54.00 74.00 54.00 N/A N/A N/A N/A 74.00 54.00 74.00 54.00 N/A N/A N/A N/A 74.00 54.00 74.00 54.00 74.00 54.00 Margin (dB) N/A N/A N/A N/A 18.70 10.27 17.58 0.88 25.30 17.70 N/A N/A N/A N/A 17.72 0.97 25.30 17.87 N/A N/A N/A N/A 17.83 9.58 18.24 2.03 25.46 18.58 Page 22 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11g Mode: Frequency (MHz) Receiver Reading (dBV) Detector 2412.00 65.70 PK 2412.00 57.21 AV 2412.00 65.83 PK 2412.00 57.35 AV 2390.00 25.83 PK 2390.00 14.97 AV 4824.00 57.15 PK 4824.00 42.84 AV 7236.00 45.19 PK 7236.00 32.18 AV 2437.00 65.07 PK 2437.00 56.66 AV 2437.00 65.20 PK 2437.00 56.70 AV 4874.00 56.44 PK 4874.00 42.19 AV 7311.00 45.22 PK 7311.00 32.19 AV 2462.00 64.77 PK 2462.00 55.98 AV 2462.00 66.03 PK 2462.00 56.79 AV 2483.50 27.13 PK 2483.50 15.01 AV 4924.00 57.63 PK 4924.00 43.28 AV 7386.00 46.82 PK 7386.00 34.16 AV Rx Antenna Polar Factor (H/V) (dB/m) Cable loss (dB) Amplifier Gain (dB) Low Channel: 2412 MHz H 28.12 1.81 0.00 H 28.12 1.81 0.00 V 28.12 1.81 0.00 V 28.12 1.81 0.00 V 28.08 1.80 0.00 V 28.08 1.80 0.00 V 32.95 3.19 37.20 V 32.95 3.19 37.20 V 35.81 4.77 37.27 V 35.81 4.77 37.27 Middle Channel: 2437 MHz H 28.17 1.82 0.00 H 28.17 1.82 0.00 V 28.17 1.82 0.00 V 28.17 1.82 0.00 V 33.05 3.26 37.21 V 33.05 3.26 37.21 V 36.01 4.64 37.36 V 36.01 4.64 37.36 High Channel: 2462 MHz H 28.22 1.83 0.00 H 28.22 1.83 0.00 V 28.22 1.83 0.00 V 28.22 1.83 0.00 V 28.27 1.84 0.00 V 28.27 1.84 0.00 V 33.15 3.27 37.22 V 33.15 3.27 37.22 V 36.20 4.51 37.46 V 36.20 4.51 37.46 Corrected Amplitude (dBV/m) 95.63 87.14 95.76 87.28 55.71 44.85 56.09 41.78 48.50 35.49 95.06 86.65 95.19 86.69 55.54 41.29 48.51 35.48 94.82 86.03 96.08 86.84 57.24 45.12 56.83 42.48 50.07 37.41 Limit (dBV/m) N/A N/A N/A N/A 74.00 54.00 74.00 54.00 74.00 54.00 N/A N/A N/A N/A 74.00 54.00 74.00 54.00 N/A N/A N/A N/A 74.00 54.00 74.00 54.00 74.00 54.00 Margin (dB) N/A N/A N/A N/A 18.29 9.15 17.91 12.22 25.50 18.51 N/A N/A N/A N/A 18.46 12.71 25.49 18.52 N/A N/A N/A N/A 16.76 8.88 17.17 11.52 23.93 16.59 Page 23 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11n ht20 Mode: Frequency (MHz) Receiver Reading (dBV) Detector 2412.00 66.34 PK 2412.00 56.04 AV 2412.00 67.52 PK 2412.00 57.51 AV 2390.00 24.56 PK 2390.00 13.92 AV 4824.00 55.34 PK 4824.00 41.28 AV 7236.00 46.82 PK 7236.00 34.25 AV 2437.00 66.38 PK 2437.00 56.17 AV 2437.00 67.82 PK 2437.00 57.74 AV 4874.00 56.31 PK 4874.00 42.25 AV 7311.00 46.85 PK 7311.00 35.04 AV 2462.00 66.45 PK 2462.00 56.57 AV 2462.00 68.06 PK 2462.00 57.94 AV 2483.50 25.63 PK 2483.50 14.31 AV 4924.00 56.85 PK 4924.00 42.68 AV 7386.00 46.73 PK 7386.00 35.12 AV Rx Antenna Polar Factor (H/V) (dB/m) Cable loss (dB) Amplifier Gain (dB) Low Channel: 2412 MHz H 28.12 1.81 0.00 H 28.12 1.81 0.00 V 28.12 1.81 0.00 V 28.12 1.81 0.00 V 28.08 1.80 0.00 V 28.08 1.80 0.00 V 32.95 3.19 37.20 V 32.95 3.19 37.20 V 35.81 4.77 37.27 V 35.81 4.77 37.27 Middle Channel: 2437 MHz H 28.17 1.82 0.00 H 28.17 1.82 0.00 V 28.17 1.82 0.00 V 28.17 1.82 0.00 V 33.05 3.26 37.21 V 33.05 3.26 37.21 V 36.01 4.64 37.36 V 36.01 4.64 37.36 High Channel: 2462 MHz H 28.22 1.83 0.00 H 28.22 1.83 0.00 V 28.22 1.83 0.00 V 28.22 1.83 0.00 V 28.27 1.84 0.00 V 28.27 1.84 0.00 V 33.15 3.27 37.22 V 33.15 3.27 37.22 V 36.20 4.51 37.46 V 36.20 4.51 37.46 Corrected Amplitude (dBV/m) 96.27 85.97 97.45 87.44 54.44 43.80 54.28 40.22 50.13 37.56 96.37 86.16 97.81 87.73 55.41 41.35 50.14 38.33 96.50 86.62 98.11 87.99 55.74 44.42 56.05 41.88 49.98 38.37 Limit (dBV/m) N/A N/A N/A N/A 74.00 54.00 74.00 54.00 74.00 54.00 N/A N/A N/A N/A 74.00 54.00 74.00 54.00 N/A N/A N/A N/A 74.00 54.00 74.00 54.00 74.00 54.00 Margin (dB) N/A N/A N/A N/A 19.56 10.20 19.72 13.78 23.87 16.44 N/A N/A N/A N/A 18.59 12.65 23.86 15.67 N/A N/A N/A N/A 18.26 9.58 17.95 12.12 24.02 15.63 Page 24 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Test plots(802.11 b mode Low channel was the worst) Horizontal: Fundamental Test with Band Rejection Filter Report No.: RDG180807019-00A Page 25 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Vertical: Fundamental Test with Band Rejection Filter Report No.: RDG180807019-00A Page 26 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.247(a) (2)6 dB EMISSION BANDWIDTH Applicable Standard According to FCC §15.247(a) (2) Systems using digital modulation techniques may operate in the 902928 MHz, 24002483.5 MHz, and 57255850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz. Test Procedure a) Set RBW = 100 kHz. b) Set the video bandwidth (VBW) 3×RBW. c) Detector = Peak. d) Trace mode = max hold. e) Sweep = auto couple. f) Allow the trace to stabilize. g) Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. EUT Spectrum Analyzer Test Equipment List and Details Manufacturer R&S Unknown Description Spectrum Analyzer Coaxial Cable Model FSU 26 C-SJ00-0010 Serial Number Calibration Date Calibration Due Date 200256 2018-01-04 2019-01-04 C0010/02 Each time N/A * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Page 27 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: 28.5 C 59 % 99.4 kPa Report No.: RDG180807019-00A * The testing was performed by Nami Quan on 2018-08-15. Test Mode: Transmitting Test Result: Compliant. Please refer to the following table and plots. Test mode 802.11b 802.11g 802.11n ht20 Channel Low Middle High Low Middle High Low Middle High Frequency (MHz) 2412 2437 2462 2412 2437 2462 2412 2437 2462 6 dB Bandwidth (MHz) 8.56 9.07 9.07 16.48 16.49 16.51 17.59 17.59 17.56 Limit (MHz) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Page 28 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 6dB bandwidth: 802.11b Low Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 D1 6.88 dBm 1 PK 1 MAXH 0 D2 0.88 dBm * RBW 100 kHz * VBW 300 kHz SWT 15 ms 1 Delta 1 [T1 ] 0.47 dB 8.558461538 MHz Marker 1 [T1 ] 0.65 dBm 2.407544103 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.412 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:34:56 802.11b Middle Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 D1 6.75 dBm 1 PK 1 MAXH 0 D2 0.75 dBm * RBW 100 kHz * VBW 300 kHz SWT 15 ms 1 Delta 1 [T1 ] -0.07 dB 9.068205128 MHz Marker 1 [T1 ] 0.51 dBm 2.432483077 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.437 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:32:02 Page 29 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11b High Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 D1 6.81 dBm 1 PK 1 MAXH 0 D2 0.81 dBm * RBW 100 kHz * VBW 300 kHz SWT 15 ms 1 Delta 1 [T1 ] -0.06 dB 9.067179487 MHz Marker 1 [T1 ] 0.41 dBm 2.457531282 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.462 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:31:13 802.11g Low Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 1 PK MAXH 0 -10 D1 1.45 dBm D2 -4.55 dBm1 * RBW 100 kHz * VBW 300 kHz SWT 15 ms Delta 1 [T1 ] 2.61 dB 16.476410256 MHz Marker 1 [T1 ] -6.69 dBm 2.403792821 GHz A 1 LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.412 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:36:58 Page 30 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11g Middle Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 1 PK MAXH 0 -10 D1 1.5 dBm D2 -4.5 dBm 1 * RBW 100 kHz * VBW 300 kHz SWT 15 ms Delta 1 [T1 ] 2.12 dB 16.494358974 MHz Marker 1 [T1 ] -6.84 dBm 2.428774872 GHz A 1 LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.437 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:37:34 802.11g High Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 1 PK MAXH 0 -10 D1 1.6 dBm D2 -4.4 dBm 1 * RBW 100 kHz * VBW 300 kHz SWT 15 ms Delta 1 [T1 ] 2.25 dB 16.514358974 MHz Marker 1 [T1 ] -6.45 dBm 2.453754872 GHz A 1 LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.462 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:38:18 Page 31 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11n ht20 Low Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 1 PK MAXH 0 -10 D1 1.7 dBm 1 D2 -4.3 dBm * RBW 100 kHz * VBW 300 kHz SWT 15 ms Delta 1 [T1 ] 0.92 dB 17.588205128 MHz Marker 1 [T1 ] -4.52 dBm 2.403193846 GHz A 1 LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.412 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:40:25 802.11n ht20 Middle Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 1 PK MAXH 0 -10 D1 1.65 dBm 1 D2 -4.35 dBm * RBW 100 kHz * VBW 300 kHz SWT 15 ms Delta 1 [T1 ] 1.10 dB 17.588205128 MHz Marker 1 [T1 ] -4.69 dBm 2.428193846 GHz A 1 LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.437 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:39:49 Page 32 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11n ht20 High Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB 10 1 PK MAXH 0 -10 D1 1.7 dBm 1 D2 -4.3 dBm * RBW 100 kHz * VBW 300 kHz SWT 15 ms Delta 1 [T1 ] 0.78 dB 17.562051282 MHz Marker 1 [T1 ] -4.24 dBm 2.453220000 GHz A 1 LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.462 GHz 4 MHz/ Span 40 MHz Date: 15.AUG.2018 11:38:56 Page 33 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER Applicable Standard According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at its maximum power control level. Power must be summed across all antennas and antenna elements. The average must not include any time intervals during which the transmitter is off or is transmitting at a reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods), the maximum conducted output power is the highest total transmit power occurring in any mode. Test Procedure 1. Place the EUT on a bench and set it in transmitting mode. 2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test equipment. 3. Add a correction factor to the display. 4. Set the power Meter to test Peak output power, record the result as peak power. 5. Set the power meter to test average output power, record the result as average power. EUT Power Meter Test Equipment List and Details Manufacturer Agilent Unknown Description Model USB Wideband Power Sensor U2022XA Coaxial Cable C-SJ00-0010 Serial Number MY5417006 C0010/02 Calibration Date 2017-12-11 Each time Calibration Due Date 2018-12-11 N/A * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Page 34 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: 28.5 C 59 % 99.4 kPa Report No.: RDG180807019-00A * The testing was performed by Nami Quan on 2018-08-15. Test Mode: Transmitting Test Result: Compliant. Please refer to the following table. Test mode 802.11b 802.11g 802.11n ht20 Channel Low Middle High Low Middle High Low Middle High Frequency (MHz) 2412 2437 2462 2412 2437 2462 2412 2437 2462 Max Peak Conducted Output Power (dBm) 19.44 19.23 19.44 21.46 21.72 21.83 21.38 21.88 21.51 Max Conducted Average Output Power (dBm) 15.90 15.95 15.98 13.10 13.22 13.39 13.13 13.48 13.40 Limit (dBm) 30 30 30 30 30 30 30 30 30 Page 35 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.247(d) 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE Applicable Standard According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). Test Procedure 1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. 2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. 3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span including 100 kHz bandwidth from band edge. 4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. 5. Repeat above procedures until all measured frequencies were complete. Test Equipment List and Details Manufacturer R&S Unknown Description Model Spectrum Analyzer Coaxial Cable FSU 26 C-SJ00-0010 Serial Number 200256 C0010/02 Calibration Calibration Date Due Date 2018-01-04 2019-01-04 Each time N/A * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Page 36 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: 28.5 C 59 % 99.4 kPa Report No.: RDG180807019-00A * The testing was performed by Nami Quan on 2018-08-15. Test mode: Transmitting Test Result: Compliant. Please refer to following plots. Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 802.11b: Band Edge, Left Side * Att 25 dB * RBW 100 kHz * VBW 300 kHz SWT 20 ms Marker 2 [T1 ] -38.19 dBm 2.397024000 GHz Marker 1 [T1 ] 6.29 dBm 2.411040000 GHz A 1 LVL -10 -13.71dBm -20 -30 2 3DB -40 -50 -60 -70 -80 Center 2.4 GHz 4.8 MHz/ Span 48 MHz Date: 15.AUG.2018 13:04:18 Page 37 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11b: Band Edge, Right Side Ref 20 dBm 20 Offset 0.5 dB 10 1 1 PK MAXH 0 * Att 25 dB * RBW 100 kHz * VBW 300 kHz SWT 10 ms -13.66dBm Marker 2 [T1 ] -51.26 dBm 2.515664000 GHz Marker 1 [T1 ] 6.34 dBm 2.462516000 GHz A LVL -10 -20 -30 3DB -40 2 -50 -60 -70 -80 Center 2.4835 GHz 8.6 MHz/ Span 86 MHz Date: 15.AUG.2018 13:08:48 Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 802.11g: Band Edge, Left Side * Att 25 dB * RBW 100 kHz * VBW 300 kHz SWT 20 ms Marker 2 [T1 ] -37.30 dBm 2.399712000 GHz Marker 1 [T1 ] 1.63 dBm 2.413344000 GHz A 1 LVL -10 -18.37dBm -20 -30 2 3DB -40 -50 -60 -70 -80 Center 2.4 GHz 4.8 MHz/ Span 48 MHz Date: 15.AUG.2018 11:59:16 Page 38 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11g: Band Edge, Right Side Ref 20 dBm 20 Offset 0.5 dB * Att 10 1 PK 1 MAXH 0 25 dB * RBW 100 kHz * VBW 300 kHz SWT 10 ms -17.97dBm Marker 2 [T1 ] -44.21 dBm 2.485220000 GHz Marker 1 [T1 ] 2.03 dBm 2.463204000 GHz A LVL -10 -20 -30 3DB -40 2 -50 -60 -70 -80 Center 2.4835 GHz 8.6 MHz/ Span 86 MHz Date: 15.AUG.2018 11:55:30 802.11n ht20 Band Edge, Left Side Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 * Att 25 dB * RBW 100 kHz * VBW 300 kHz SWT 20 ms Marker 2 [T1 ] -36.34 dBm 2.397984000 GHz Marker 1 [T1 ] 1.56 dBm 2.414592000 GHz A 1 LVL -10 -18.44dBm -20 -30 2 3DB -40 -50 -60 -70 -80 Center 2.4 GHz 4.8 MHz/ Span 48 MHz Date: 15.AUG.2018 11:49:42 Page 39 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A 802.11n ht20 Band Edge, Right Side Ref 20 dBm 20 Offset 0.5 dB * Att 10 1 PK 1 MAXH 0 25 dB * RBW 100 kHz * VBW 300 kHz SWT 10 ms -17.98dBm Marker 2 [T1 ] -43.40 dBm 2.484188000 GHz Marker 1 [T1 ] 2.02 dBm 2.463204000 GHz A LVL -10 -20 -30 3DB -40 2 -50 -60 -70 -80 Center 2.4835 GHz 8.6 MHz/ Span 86 MHz Date: 15.AUG.2018 11:53:24 Page 40 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A FCC §15.247(e) - POWER SPECTRAL DENSITY Applicable Standard For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density. Test Procedure 1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. 2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. 3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth. 4. Use the peak marker function to determine the maximum amplitude level. Test Equipment List and Details Manufacturer R&S Unknown Description Model Spectrum Analyzer Coaxial Cable FSU 26 C-SJ00-0010 Serial Number 200256 C0010/02 Calibration Calibration Date Due Date 2018-01-04 2019-01-04 Each time N/A * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Test Data Environmental Conditions Temperature: Relative Humidity: ATM Pressure: 28.5 C 59 % 99.4 kPa * The testing was performed by Nami Quan on 2018-08-15. Page 41 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Test Result: Compliance Test Mode: Transmitting Test Result: Compliant. Please refer to the following table and plots Report No.: RDG180807019-00A Test mode 802.11b 802.11g 802.11n ht20 Channel Low Middle High Low Middle High Low Middle High Frequency (MHz) 2412 2437 2462 2412 2437 2462 2412 2437 2462 PSD (dBm/3kHz) -6.82 -6.06 -5.67 -6.36 -5.55 -5.24 -6.36 -5.86 -5.30 Limit (dBm/3kHz) 8 8 8 8 8 8 8 8 8 Power Spectral Density, 802.11b Low Channel Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 -10 * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 1.45 s 1 Marker 1 [T1 ] -6.82 dBm 2.412000000 GHz A LVL -20 -30 3DB -40 -50 -60 -70 -80 Center 2.412 GHz 1.284 MHz/ Span 12.84 MHz Date: 15.AUG.2018 13:12:00 Page 42 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Power Spectral Density, 802.11b Middle Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 1.55 s Marker 1 [T1 ] -6.06 dBm 2.437000000 GHz 10 A 1 PK MAXH 0 LVL 1 -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.437 GHz 1.3605 MHz/ Span 13.605 MHz Date: 15.AUG.2018 13:05:52 Power Spectral Density, 802.11b High Channel Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 1.55 s 1 Marker 1 [T1 ] -5.67 dBm 2.462000000 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.462 GHz 1.3605 MHz/ Span 13.605 MHz Date: 15.AUG.2018 13:08:23 Page 43 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Power Spectral Density, 802.11g Low Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 2.8 s Marker 1 [T1 ] -6.36 dBm 2.412000000 GHz 10 A 1 PK MAXH 0 LVL 1 -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.412 GHz 2.472 MHz/ Span 24.72 MHz Date: 15.AUG.2018 11:58:54 Power Spectral Density, 802.11g Middle Channel Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 2.8 s 1 Marker 1 [T1 ] -5.55 dBm 2.437000000 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.437 GHz 2.4735 MHz/ Span 24.735 MHz Date: 15.AUG.2018 11:56:50 Page 44 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Power Spectral Density, 802.11g High Channel Ref 20 dBm 20 Offset 0.5 dB * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 2.8 s Marker 1 [T1 ] -5.24 dBm 2.462000000 GHz 10 A 1 PK MAXH 0 1 LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.462 GHz 2.4765 MHz/ Span 24.765 MHz Date: 15.AUG.2018 11:55:08 Power Spectral Density, 802.11n ht20 Low Channel Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 3 s 1 Marker 1 [T1 ] -6.36 dBm 2.412000000 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.412 GHz 2.6385 MHz/ Span 26.385 MHz Date: 15.AUG.2018 11:49:20 Page 45 of 46 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807019-00A Power Spectral Density, 802.11n ht20 Middle Channel Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 3 s 1 Marker 1 [T1 ] -5.86 dBm 2.437000000 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.437 GHz 2.6385 MHz/ Span 26.385 MHz Date: 15.AUG.2018 11:51:06 Power Spectral Density, 802.11n ht20 High Channel Ref 20 dBm 20 Offset 0.5 dB 10 1 PK MAXH 0 * Att 25 dB * RBW 3 kHz * VBW 10 kHz SWT 3 s 1 Marker 1 [T1 ] -5.30 dBm 2.462000000 GHz A LVL -10 -20 -30 3DB -40 -50 -60 -70 -80 Center 2.462 GHz 2.634 MHz/ Span 26.34 MHz Date: 15.AUG.2018 11:52:59 ***** END OF REPORT ***** Page 46 of 46Acrobat Distiller 9.0.0 (Windows)