275985-38253-8967 SNU 5 SLi de en fr nl cs pl hu ru

Download the Operation & Installation Guide

Stiebel SNU 5 Undersink Water Heater - Builders Supplies from Gottlieb's. Go where the trade people shop

BEDIENUNG UND INSTALLATION OPERATION AND INSTALLATION UTILISATION ET INSTALLATION GEBRUIK EN INSTALLATIE OBSLUHA A INSTALACE OBS

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 15 Pages, 2.67MB

Document DEVICE REPORT1540530150 SNU 5 Operating and Installation Guide-1 (1)
BEDIENUNG UND INSTALLATION OPERATION AND INSTALLATION UTILISATION ET INSTALLATION GEBRUIK EN INSTALLATIE OBSLUHA A INSTALACE OBSLUGA I INSTALACJA HASZNÁLATI ÉS TELEPÍTÉSI ÚTMUTATÓ   

Offener (druckloser) Warmwasser-Kleinspeicher | Open vented (non-pressurised) small water heater | Mini-ballon d'eau chaude à écoulement libre | Open (drukloze), kleine warmwaterboiler | Malý beztlakový zásobník teplé vody | Otwarty (bezcinieniowy) maly pojemnociowy ogrzewacz wody | Nyitott rendszer (nyomásmentes) kisméret melegvíztároló |  ()   

»» SNU 5 SL antitropf comfort »» SNU 5 SLi antitropf comfort

antitropf comfort °C

85

35

65 Eco 55

OPERATION General information

OPERATION
1. General information
The chapters "Special Information" and "Operation" are intended for both the user and qualified contractors. The chapter "Installation" is intended for qualified contractors.
Note Read these instructions carefully before using the appliance and retain them for future reference. Pass on the instructions to a new user if required.

Symbol
!

Meaning
Material losses (appliance damage, consequential losses and environmental pollution)
Appliance disposal

ffThis symbol indicates that you have to do something. The action you need to take is described step by step.
1.3 Units of measurement
Note All measurements are given in mm unless stated otherwise.

1.1 Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk
! Here, possible consequences are listed that may result
from failure to observe the safety instructions. ffSteps to prevent the risk are listed.

1.1.2 Symbols, type of risk

Symbol
!

Type of risk Injury
Electrocution

Burns (burns, scalding)

1.1.3 Keywords

KEYWORD DANGER
WARNING
CAUTION

Meaning
Failure to observe this information will result in serious injury or death.
Failure to observe this information may result in serious injury or death.
Failure to observe this information may result in non-serious or minor injury.

1.2 Other symbols in this documentation
Note General information is identified by the symbol shown on the left. ffRead these texts carefully.

2. Safety

2.1 Intended use
This open vented (non-pressurised) appliance is designed for heating domestic hot water. The appliance can supply one draw-off point.
This appliance is intended for domestic use. It can be used safely by untrained persons. The appliance can also be used in a non-domestic environment, e.g. in a small business, as long as it is used in the same way.
Any other use beyond that described shall be deemed inappropriate. Observation of these instructions and of instructions for any accessories used is also part of the correct use of this appliance.

2.2 General safety instructions

WARNING Burns There is a risk of scalding at outlet temperatures in excess of 43 °C.

WARNING Injury
! The temperature selector should only be removed by a
qualified contractor.

!

WARNING Injury The appliance may be used by children aged 8 and up and

persons with reduced physical, sensory or mental capa-

bilities or a lack of experience and know-how, provided

that they are supervised or they have been instructed on

how to use the appliance safely and have understood

the resulting risks. Children must never play with the

appliance. Children must never clean the appliance or

perform user maintenance unless they are supervised.

Where children or persons with limited physical, sensory or mental abilities are allowed to use this appliance, we recommend a permanent temperature limit. A qualified contractor can set the limit.

! Material losses Protect the appliance and its tap against frost.

14|SNU 5www.stiebel-eltron.com

D0000047838
ENGLISH

OPERATION Appliance description

! Material losses Never subject the appliance to water pressure. The tap outlet has a vent function. Scale build-up can block the outlet and subject the appliance to pressure. ffNever seal the tap outlet. ffOnly use special aerators for non-pressurised water heaters. ffNever use a hose with aerator to extend the tap outlet.
! Material losses Connecting the appliance via a time switch will cause an unintentional reset of the high limit safety cut-out. ffNever connect the appliance to the power supply via a time switch.
2.3 CE designation
The CE designation shows that the appliance meets all essential requirements according to the: -- Low Voltage Directive -- Electromagnetic Compatibility Directive

2
1
1 Temperature selector 2 Heat-up indicator °C = Cold. On this setting, the appliance is protected from
frost. The tap and the water line are not protected. Eco = Recommended energy saving setting (approx. 60 °C),
minor scaling 85 = Maximum selectable temperature
Note A qualified contractor can set a temperature limit on the appliance (see chapter "Installation / Settings / Setting the temperature limit").

2.4 Test symbols
See type plate on the appliance.
3. Appliance description
The open vented (non-pressurised) appliance constantly maintains the water content at the pre-selected temperature. The appliance may only be installed with taps for open vented (non-pressurised) water heaters (see chapter "Installation / Appliance description / Accessories").
thermostop function
The thermostop function (thermal separation) prevents the tap becoming hot in standby mode.
Anti-drip function
The anti-drip function prevents expansion water from escaping from the tap during heating. When water is heated, gas bubbles are formed. The amount of gas bubbles depends on the water quality. At temperatures > 75 °C the rising gas bubbles can cause residual water to drip from the tap outlet.
Subject to design, some taps have a tendency to drip for a short while after being closed. This dripping is caused by residual water escaping from the tap outlet and is not linked to expansion water.
3.1 Operation
The required DHW outlet temperature can be set at the temperature selector. The heat-up indicator illuminates during the heat-up process.

4. Cleaning, care and maintenance
ffNever use abrasive or corrosive cleaning agents. A damp cloth is sufficient for cleaning the appliance.
ffCheck the tap regularly. You can remove limescale deposits at the outlet using commercially available descaling agents.

5. Troubleshooting

Problem

Cause

Remedy

The appliance does not The temperature selector Switch the appliance on

supply hot water.

is set to "°C".

by turning the tempera-

ture selector.

No power to the appli- Check the plug and the

ance.

fuses/MCBs in the fuse

box.

Water can only be drawn The aerator in the tap is Descale / replace the

at a reduced rate.

scaled up.

aerator.

Loud boiling noises in- The appliance is scaled Have the appliance

side the appliance.

up.

descaled by a qualified

contractor.

Water drips from the tap Frequent minimal draw- Change your draw-off outlet during the heat-up off amounts (< 0.4 l/min). pattern (> 0.4 l/min). process.

If you cannot remedy the fault, notify your qualified contractor. To facilitate and speed up your request, provide the number from the type plate (000000-0000-000000).

Nr.: ...... - .... - ...... Typ: SNU 5

D0000047804

www.stiebel-eltron.com

SNU 5|15

INSTALLATION Safety

INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
6.2 Instructions, standards and regulations

8. Preparations
ffFlush the water line thoroughly.
Water installation A safety valve is not required.
Taps Sealed taps are not permitted. ffInstall an open tap.
8.1 Installation site
! Material losses Install the appliance in a room free from the risk of frost.

Note Observe all applicable national and regional regulations and instructions.

! Material losses Mount the appliance on the wall. The wall must have a sufficient load-bearing capacity.

7. Appliance description
The open vented (non-pressurised) appliance is only suitable for undersink installation. The appliance is intended to supply one draw-off point for heating cold water.

Note The appliance is only suitable for undersink installation. The water connections of the appliance point upwards.
Always install the appliance vertically and near the draw-off point.

7.1 Standard delivery
Delivered with the appliance: -- Wall mounting bracket

520-570 820
D0000033291

7.2 Accessories

°C

85

35

65 Eco 55

7.2.1 Required accessories

The following taps are available as accessories for open vented operation:

Mixer taps -- WST, WUT

Mono lever mixer taps -- MEW, MES, MEWC

Sensor tap

-- WEN

°C

85

35

65 Eco 55

7.2.2 Further accessories

-- Strainer for the "cold water inlet" connection

550-600 850
D0000033294

16|SNU 5www.stiebel-eltron.com

ENGLISH

INSTALLATION Installation

9. Installation
9.1 Appliance installation
ffMark out the drill holes using the installation template (see middle part of these instructions).
ffDrill the holes and insert suitable rawl plugs. ffSecure the wall mounting bracket using suitable screws. ffHang the appliance on the wall mounting bracket.
Note Surplus cable can be stored in the cable compartment.

! Material losses The appliance may develop a leak and cease functioning. ffNever subject the appliance to water pressure. ffNever interchange the water connections. ffSet the flow rate (see tap instructions). Observe the maximum permissible flow rate with a fully opened tap (see chapter "Installation / Specification / Data table").
Match up the colour coding on the tap water connections and the appliance: -- R. h. side blue = "Cold water inlet" -- L. h. side red = "DHW outlet" ffSecure the water connections from the tap to the appliance.
Note Ensure that the water connections are not kinked during installation. Prevent any tensioning during installation.

9.2 Water connection
! Material losses Carry out all water connection and installation work in accordance with regulations.
! Material losses Counterhold with a suitable spanner when tightening the fittings.

22

19

D0000034827

9.3 Power supply
WARNING Electrocution Carry out all electrical connection and installation work in accordance with relevant regulations.
WARNING Electrocution Ensure the appliance can be separated from the power supply by an isolator that disconnects all poles with at least 3 mm contact separation.

! Material losses The voltage specified on the type plate must match the mains voltage. ffObserve the type plate.

The following electrical connections are permissible:

Connection to a freely accessible standard socket
Permanent connection to an appliance junction box with earth conductor

SNU 5 SL 1 kW X
X

SNU 5 SLi X
X

com for t
°C
85 35
65 Eco 55

D0000034825

www.stiebel-eltron.com

SNU 5|17

INSTALLATION Commissioning

10. Commissioning
WARNING Electrocution Commissioning may only be carried out by a qualified contractor in accordance with safety regulations.

11. Settings
11.1 Setting the temperature limit

10.1 Initial start-up

ffEither open the DHW valve of the tap or set the mono lever mixer tap to "hot" until the water that flows out is free of air bubbles.
ffInsert the plug into the standard socket or set the fuse/MCB in the fuse box.
ffSelect a temperature.
Note If you fail to follow the correct sequence (first water, then power), the high limit safety cut-out will respond. Proceed as follows: ffFill the appliance with water. ffBriefly disconnect the appliance from the power
supply.
10.1.1 Appliance handover ffExplain the functions of the appliance to the user. Show the
user how to operate the appliance. ffMake the user aware of potential dangers, especially the risk
of scalding. ffHand over these instructions and, if applicable, the instruc-
tions for any accessories.
10.2 Recommissioning
See chapter "Installation / Commissioning / Initial start-up".

26_02_06_0204 D0000047839

1

°C

85 35

65 Eco 55
2

1 Temperature selector 2 Limiting ring
Placing the limiting ring behind the temperature selector allows you to limit the setting range of the temperature selector to a specific maximum temperature. ffTurn the temperature selector to zero (fully anti-clockwise to
"°C"). ffPull off the temperature selector and the limiting ring. ffPush the limiting ring with the required maximum setting
onto the adjusting shaft. ffFit the temperature selector in the zero setting (°C).

12. Shutdown
ffIsolate the appliance from the power supply by removing the plug or by tripping the fuse/MCB in the fuse box.
ffDrain the appliance (see chapter "Installation / Maintenance / Draining the appliance").

13. Troubleshooting

Problem

Cause

Remedy

The appliance does The high limit safety Remedy the cause of the fault. not supply hot water. cut-out has responded. If necessary, replace the tem-
perature controller. Allow the appliance to cool down. If you have isolated the appliance from the power supply, the high limit safety cut-out will be automatically reset.

The strainer is contam- Clean / replace the strainer in

inated.

the "cold water inlet" connec-

tion.

Loud boiling noises The appliance is scaled Descale the appliance. inside the appliance. up.

The tap drips for a while after it has been closed.

The residual water Replace the aerator in the tap is not held in the tap outlet or the tap. outlet.

The tap drips when An unsuitable tap is Replace the tap (see chapter

the appliance is being used, e.g. a WAT "Installation / Appliance de-

heating up.

anti-drip tap.

scription / Accessories").

The anti-drip function Replace the appliance. is faulty.

18|SNU 5www.stiebel-eltron.com

D0000047841
ENGLISH

INSTALLATION Maintenance

14. Maintenance

14.4 Cleaning the strainer

WARNING Electrocution Before any work on the appliance, disconnect all poles of the appliance from the power supply.
ffDismount the appliance for maintenance work.

14.1 Draining the appliance

WARNING Burns Hot water may escape during the draining process. ffDrain the appliance via the connector.
14.2 Opening the appliance

°C 85
35 65 Eco 55
ffDetach the "cold water inlet" connection. ffUsing pliers, remove the strainer from the "cold water inlet"
connection. ffDescale or replace the strainer.

°C 85
35 65 Eco 55
ffPull off the temperature selector and the limiting ring. ffRemove the screws underneath the temperature selector. ffOpen the appliance cover by lowering the bolt screws in-
wards and pivot the cover upwards, then remove it.

D0000047843

14.5 Checking the earth conductor
ffPull off the temperature selector and the limiting ring. ffCheck the earth conductor (in Germany, e.g. BGV A3) across
a temperature controller fixing screw and the earth conductor contact of the power cable.
14.6 Replacing the power cable
The power cable must only be replaced by a qualified electrician with the original spare part. Alternatively, the H05VV-F3x1.0 cable may be used.

D0000034824

14.3 Descaling the appliance

! Material losses Never treat the cylinder surface with descaling agents.
ffRemove the flanged immersion heater. ffCarefully tap the heating element to remove large limescale
deposits. ffImmerse the heating element up to the flange plate in desca-
ling agent.

ffRoute the power cable along the cable guide.
14.7 Positioning the temperature sensor in its protective pipe
ffWhen replacing the temperature controller, guide the temperature sensor into its protective pipe.
ffSecure the temperature sensor in place below the earthed plug.

185

26_02_06_0219

www.stiebel-eltron.com

SNU 5|19

INSTALLATION Specification

15. Specification

15.1 Dimensions and connections

263

230

140

70

14

421

328

c06 c01 100

15.3 Heat-up diagram
The heat-up period depends on the degree of scaling and residual heat. For the heat-up time for a cold water supply of 10 °C and a maximum temperature setting, see the diagram.

84_02_02_0044

30

25

1

20

15

2

10

5

0 35 40 45 50 55 60 65 70 75 80 85

x Temperature settings in °C y Duration in min 1 1 kW appliance 2 2 kW appliance

15.4 Country-specific approvals and certifications
The test symbols can be seen on the type plate.

15.5 Extreme operating and fault conditions
In the case of faults, a peak temperature up to 100°C may briefly occur in the system.

D0000035039

c01 Cold water Inlet c06 DHW outlet

Male thread Male thread

SNU 5 SL 1 kW G 3/8 A G 3/8 A

SNU 5 SLi G 3/8 A G 3/8 A

15.2 Wiring diagram
1/N/PE ~ 220 - 240 V

LN

85_02_06_0001

20|SNU 5www.stiebel-eltron.com

ENGLISH

INSTALLATION Specification

15.6 Data table

SNU 5 SL 1 kW

SNU 5 SLi

SNU 5 SLi

221116

221121

229467

Hydraulic data

Nominal capacity

l

5

5

5

Mixed water volume 40 °C

l

10

10

10

Electrical data

Rated voltage

V

220

230

240

220

230

240

220

230

240

Rated output

kW

0.9

1.0

1.1

1.8

2.0

2.2

1.8

2.0

2.2

Rated current

A

4.1

4.3

4.5

8.3

8.7

9.1

8.3

8.7

9.1

Fuse/MCB rating

A

10

10

10

10

10

10

10

10

10

Phases

1/N/PE

1/N/PE

1/N/PE

Frequency

Hz

50/60

50/60

50/60

Application limits

Temperature setting range

°C

35 - 85

35 - 85

35 - 85

Max. permissible pressure

MPa

0

0

0

Max. flow rate

l/min

5

5

5

Energy data

Standby power consumption over 24 h at 38 °C kWh

0.09

0.09

0.09

Standby energy consumption/24 h at 65 °C

kWh

0.2

0.2

0.2

Energy efficiency category

A

A

A

Versions

IP rating

IP24

IP24

IP24

Type

Open vented

Open vented

Open vented

Type of installation

Undersink

Undersink

Undersink

Internal cylinder material

PP

PP

PP

Thermal insulation material

Polystyrene

Polystyrene

Polystyrene

Casing material

PS

PS

PS

Colour

white

white

white

Connections

Water connection

G 3/8

G 3/8

G 3/8

Dimensions

Depth

mm

230

230

230

Height

mm

421

421

421

Width

mm

263

263

263

Weights

Weight

kg

3.0

3.0

3.0

www.stiebel-eltron.com

SNU 5|21

GUARANTEE | ENVIRONMENT AND RECYCLING
Guarantee
The warranty conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products, it is increasingly the case that warranties can only be issued by those subsidiaries. Such warranties are only granted if the subsidiary has issued its own terms of warranty. No other warranty will be granted. We shall not provide any warranty for appliances acquired in countries where we have no subsidiary to sell our products. This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations.
22|SNU 5www.stiebel-eltron.com

26_02_06_0011

79 mm

140 mm

407mm 407mm

antit r opf com for t °C

85

35

65 Eco 55

263mm

antitr opf com for t °C

85

35

65 Eco 55

263mm

Who gives the warranty 1. The warranty is given by Stiebel Eltron (Aust) Pty Ltd (A.B.N. 82 066 271 083) of 6 Prohasky Street, Port Melbourne, Victoria, 3207 ("we", "us" or "our").
The warranty 2. This warranty applies to Stiebel Eltron Water Heaters ­ Models DHE 18 AU, DHE 27 AU, DEL 18 AU, DEL 27 AU, DHB-E 13 AU, DHB-E 13, DHB-E 18 AU, DHB-E 27 AU, HDBE 13 AU, HDBE 18 AU, HDBE 27 AU, DHF 13 C AU, DHF 15 C AU, DHC 4, DHC 6, DHC 8, SN 5, SN 10, SNU 5 and SNU 10 (the "unit") manufactured after 1 May 2015.
3. Subject to the warranty exclusions we will repair or replace, at our absolute discretion, a faulty component in your unit free of charge if it fails to operate in accordance with its specifications during the warranty period.
4. If we repair or replace a faulty component to your unit under this warranty, the warranty period is not extended from the time of the repair or replacement.
5. The warranty period commences on the date of completion of the installation of the unit. Where the date of completion of installation is not known, then the warranty period will commence 2 months after the date of manufacture.

9.3. The name, address and contact details (such as phone number and e-mail address) of the owner;

9.4. The address where the unit is installed and the location (e.g. in laundry);

9.5. The serial number of the unit;

9.6. The date of purchase of the unit and the name of the seller of the unit;

9.7. The date of installation of the unit;

9.8. A copy of the certificate of compliance when the unit was installed.

10. The contact details for you to make your warranty claim are:

Name: Address:
Telephone:
Contact person: E-mail:

Stiebel Eltron (Aust) Pty Ltd 6 Prohasky Street, Port Melbourne, Victoria, 3207 1800 153 351 (8.00 am to 5.00 pm AEST Monday to Friday) Customer Service Representative [email protected]

6. The warranty period for a unit used for domestic purposes is shown in the table below. Domestic purposes means that the unit is used in a domestic dwelling.

Component All components

Warranty period
5 years from the date of completion of the installation of the unit.

7. The warranty period for a unit used for commercial purposes is shown in the table below. Commercial purposes means that the unit is used for a non-domestic purpose and includes but not limited to being used in a motel, hotel, mining camp or nursing home.

11. We will arrange a suitable time with you to inspect and test the unit.
Warranty exclusions 12. We may reject your warranty claim if:
12.1. The unit was not installed by registered and qualified tradespeople.
12.2. The unit was not installed and commissioned:
(a) in Australia;
(b) in accordance with the Operating and Installation Guide; and

Component All components

Warranty period
1 year from the date of completion of the installation of the unit.

Your entitlement to make a warranty claim 8. You are entitled to make a warranty claim if:
8.1. you own the unit or if you have the owner's consent to represent the owner of the unit;
8.2. you contact us within a reasonable time of discovering the problem with the unit;

(c) in accordance with the relevant statutory and local requirements of the State or Territory in which the unit is installed.
12.3. The unit has not been operated or maintained in accordance with the Operating and Installation Guide.
12.4. The unit does not bear its original Serial Number or Rating Label.
12.5. The unit was damaged by any or any combination of the following:
(a) normal fair wear and tear;

How you make a warranty claim 9. To make a warranty claim you must provide us with the following information:
9.1. The model number of the unit;
9.2. A description of the problem with the unit;

(b) connection to an incorrect water supply;
(c) connection to water from a bore, dam or swimming pool;
(d) connection to an incorrect power supply;

(e) connection to faulty equipment, such as damaged valves;
(f) foreign matter in the water supply, such as sludge or sediment;
(g) corrosive elements in the water supply;
(h) accidental damage;
(i) act of God, including damage by flood, storm, fire, lightning strike and the like;

Australian Consumer Law 18. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
19. The Stiebel Eltron warranty for the unit is in addition to any rights and remedies you may have under the Australian Consumer Law.

(j) excessive water pressure, negative water pressure (partial vacuum) or water pressure pulsation.

12.6. The unit was damaged before it was installed e.g. it was damaged in transit.

12.7. An unauthorised person has modified, serviced, repaired or attempted to repair the unit without our consent.

12.8. Non genuine parts other than those manufactured or approved by us have been used on the unit.

13. We may charge you:

13.1. for any additional transport costs if the unit is installed more than 30 kilometres from our closest authorised service technician.

13.2. for the extra time it takes our authorised service technician to access the unit for inspection and testing if it is not sited in accordance with the Operating and Installation Guide and not readily accessible for inspection.

13.3. for any extra costs of our authorised service technician to make the unit safe for inspection.

14. You must ensure that access to the unit by our authorised service technician is safe and free from obstruction.

15. Our authorised service technician may refuse to inspect and test the unit until you provide safe and free access to it, at your cost.

16. If we reject your warranty claim in accordance with clause 12, we may charge you for our authorised service technician's labour costs to inspect and test the unit.

17. In order to properly test the unit we may remove it to another location for testing.

Deutschland STIEBEL ELTRON GmbH & Co. KG Dr.-Stiebel-Straße 33 | 37603 Holzminden Tel. 05531 702-0 | Fax 05531 702-480 [email protected] www.stiebel-eltron.de

Verkauf

Tel. 05531 702-110 | Fax 05531 702-95108 | [email protected]

Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | [email protected]

Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | [email protected]

Australia STIEBEL ELTRON Australia Pty. Ltd. 6 Prohasky Street | Port Melbourne VIC 3207 Tel. 03 9645-1833 | Fax 03 9645-4366 [email protected] www.stiebel.com.au
Austria STIEBEL ELTRON Ges.m.b.H. Eferdinger Str. 73 | 4600 Wels Tel. 07242 47367-0 | Fax 07242 47367-42 [email protected] www.stiebel-eltron.at
Belgium STIEBEL ELTRON bvba/sprl 't Hofveld 6 - D1 | 1702 Groot-Bijgaarden Tel. 02 42322-22 | Fax 02 42322-12 [email protected] www.stiebel-eltron.be
China STIEBEL ELTRON (Guangzhou) Technology Development Co., Ltd. Rm 102, F1, Yingbin-Yihao Mansion, No. 1 Yingbin Road Panyu District | 511431 Guangzhou Tel. 020 39162209 | Fax 020 39162203 [email protected] www.stiebeleltron.cn

France STIEBEL ELTRON SAS 7-9, rue des Selliers B.P 85107 | 57073 Metz-Cédex 3 Tel. 0387 7438-88 | Fax 0387 7468-26 [email protected] www.stiebel-eltron.fr
Hungary STIEBEL ELTRON Kft. Gyár u. 2 | 2040 Budaörs Tel. 01 250-6055 | Fax 01 368-8097 [email protected] www.stiebel-eltron.hu
Japan NIHON STIEBEL Co. Ltd. Kowa Kawasaki Nishiguchi Building 8F 66-2 Horikawa-Cho Saiwai-Ku | 212-0013 Kawasaki Tel. 044 540-3200 | Fax 044 540-3210 [email protected] www.nihonstiebel.co.jp
Netherlands STIEBEL ELTRON Nederland B.V. Daviottenweg 36 | 5222 BH 's-Hertogenbosch Tel. 073 623-0000 | Fax 073 623-1141 [email protected] www.stiebel-eltron.nl

Switzerland STIEBEL ELTRON AG Industrie West Gass 8 | 5242 Lupfig Tel. 056 4640-500 | Fax 056 4640-501 [email protected] www.stiebel-eltron.ch
Thailand STIEBEL ELTRON Asia Ltd. 469 Moo 2 Tambol Klong-Jik Amphur Bangpa-In | 13160 Ayutthaya Tel. 035 220088 | Fax 035 221188 [email protected] www.stiebeleltronasia.com
United Kingdom and Ireland STIEBEL ELTRON UK Ltd. Unit 12 Stadium Court Stadium Road | CH62 3RP Bromborough Tel. 0151 346-2300 | Fax 0151 334-2913 [email protected] www.stiebel-eltron.co.uk
United States of America STIEBEL ELTRON, Inc. 17 West Street | 01088 West Hatfield MA Tel. 0413 247-3380 | Fax 0413 247-3369 [email protected] www.stiebel-eltron-usa.com

Czech Republic STIEBEL ELTRON spol. s r.o. K Hájm 946 | 155 00 Praha 5 - Stodlky Tel. 251116-111 | Fax 235512-122 [email protected] www.stiebel-eltron.cz

Poland STIEBEL ELTRON Polska Sp. z o.o. ul. Dzialkowa 2 | 02-234 Warszawa Tel. 022 60920-30 | Fax 022 60920-29 [email protected] www.stiebel-eltron.pl

Denmark

Russia

Pettinaroli A/S

STIEBEL ELTRON LLC RUSSIA

Mandal Allé 21 | 5500 Middelfart

Urzhumskaya street 4,

Tel. 06341 666-6 | Fax 06341 666-0

building 2 | 129343 Moscow

[email protected]

Tel. 0495 7753889 | Fax 0495 7753887

www.stiebel-eltron.dk

[email protected]

Finland

www.stiebel-eltron.ru

STIEBEL ELTRON OY

Slovakia

Kapinakuja 1 | 04600 Mäntsälä

TATRAMAT - ohrievace vody, s.r.o.

Tel. 020 720-9988

Hlavná 1 | 058 01 Poprad

[email protected]

Tel. 052 7127-125 | Fax 052 7127-148

www.stiebel-eltron.fi

[email protected]

4<AMHCMN=hfjifb>

www.stiebel-eltron.sk
Irrtum und technische Änderungen vorbehalten! | Subject to errors and technical changes! | Sous réserve d`erreurs et de modifications techniques! | Onder voorbehoud van vergissingen en technische wijzigingen! | Salvo error o modificación técnica! | Excepto erro ou alteração técnica | Zastrzeone zmiany techniczne i

ewentualne bldy | Omyly a technické zmny jsou vyhrazeny! | A muszaki változtatások és tévedések jogát

fenntartjuk! |    .   . | Chyby a

technické zmeny sú vyhradené!

Stand 8870

A 275985-38253-8967


Adobe InDesign CC (Windows) Adobe PDF Library 10.0.1

Search Any Device: