RDG201223010A1 EN 62311 ASSESSMENT REPORT
dg06103
SONOFF TH10&TH16 LVD Health Test Report
TH10/16-DOC Temp & Humi Monitoring Smart Switch - SONOFF Official
EN IEC 62311:2020 ASSESSMENT REPORT Shenzhen Sonoff Technologies Co.,Ltd.
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 19 Pages, 1.11MB
Document DEVICE REPORT
✖
EN IEC 62311:2020 ASSESSMENT REPORT For Shenzhen Sonoff Technologies Co.,Ltd. 1001, BLDG8, Lianhua Industrial Park, shenzhen, GD, China Model: TH16 Multiple Models: TH10 Report Type: Amended Report Product Type: WiFi Smart Switch Report Number: RDG201223010A1 Report Date: 2021-01-28 Allen Qiao Reviewed By: RF Supervisor Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG201223010A1 TABLE OF CONTENTS DOCUMENT REVISION HISTORY .........................................................................................................................3 DECLARATIONS ............................................................................................................................................................ 3 EXHIBIT A EUT PHOTOGRAPHS ........................................................................................................................4 BELOW IS THE ORIGINAL REPORT.....................................................................................................................5 Page 2 of 5 Bay Area Compliance Laboratories Corp. (Dongguan) DOCUMENT REVISION HISTORY Report No.: RDG201223010A1 Revision Number 0 1 Report Number RDG180807018 RDG201223010A1 Description of Revision Original Report Amended Report Date of Revision 2018-08-31 2021-01-28 Note: This is the amended report application which was based on the original report. The differences between them as following: 1) Change the Applicant's address to 1001, BLDG8, Lianhua Industrial Park, shenzhen, GD, China. 2) Upgrade the standard to EN IEC 62311:2020 3) Changed the bridge rectifiers, the multiple model TH10 adds the relay. The change between the previous equipment and the current equipment is stated and guaranteed by the applicant. The difference between them will not affect the test items, we will keep all of the test results, but update related EUT photo. Declarations BACL is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol "". Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider the uncertainty. The extended uncertainty given in this report is obtained by combining the standard uncertainty times the coverage factor K with the 95% confidence interval. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk "". Page 3 of 5 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG201223010A1 EXHIBIT A EUT PHOTOGRAPHS For photos in this section, please refer to report No.: RDG201223010-02 A1 EXHIBIT A. Page 4 of 5 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG201223010A1 BELOW IS THE ORIGINAL REPORT Page 5 of 5 EN 62311:2008 ASSESSMENT REPORT For Shenzhen Sonoff Technologies Co.,Ltd. Building 8, Room 1001, Lianhua industrial park, Longyuan Road, Hualian community, Longhua St, Longhua dist, Shenzhen, Guangdong, China Tested Model: TH16 Multiple Model: TH10 Report Type: Original Report Product Type: WiFi Smart Switch Report Number: RDG180807018 Report Date: 2018-08-31 Allen Qiao RF Supervisor Reviewed By: Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807018 TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................3 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3 OBJECTIVE ...................................................................................................................................................................3 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3 TEST METHODOLOGY ..................................................................................................................................................3 TECHNICAL REQUIREMENTS SPECIFICATION IN EN 62311...........................................................................................4 TEST DATA ..................................................................................................................................................................5 EXHIBIT A - EUT PHOTOGRAPHS.........................................................................................................................6 Page 2 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807018 GENERAL INFORMATION Product Description for Equipment under Test (EUT) EUT Name: EUT Model: Multiple Models: Rated Input Voltage: External Dimension: Serial Number: EUT Received Date: WiFi Smart Switch TH16 TH10 90~250Vac 114mm(L)*51mm(W)*32mm(H) 180807018 2018-08-10 Note: The series product, model TH16, TH10 are electrically identical. For marketing purpose, we selected TH16 for fully test. The differences between them are explained in the declaration letter. Objective This report is prepared on behalf of Shenzhen Sonoff Technologies Co.,Ltd.in accordance with EN 62311:2008, Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz300 GHz) is to demonstrate the compliance of apparatus with the basic restrictions or reference levels on exposure of the general public related to electric, magnetic, electromagnetic fields as well as induced and contact current. The objective is to determine the compliance of EUT with EN 62311:2008. Related Submittal(s)/Grant(s) No related submittal(s). Test Methodology All measurements contained in this report were conducted with EN 62311:2008. Page 3 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807018 Technical Requirements Specification in EN 62311 General Description of Applied Standards EN 62311 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz300 GHz) is to demonstrate the compliance of apparatus with the basic restrictions or reference levels on exposure of the general public related to electric, magnetic, electromagnetic fields as well as induced and contact current. RF Exposure Evaluation Limit: According to EN 62311, the criteria listed in the below table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation as specified table 2 of Council Recommendation 1999/519/EC. Reference levels for electric, magnetic and electromagnetic fields (0 Hz to 300 GHz, unperturbed rms values) Frequency range 0-1 Hz 1-8 Hz 8-25 Hz 0,025-0,8 kHz 0,8-3 kHz 3-150 kHz 0,15-1 MHz 1-10 MHz 10-400 MHz 400-2 000 MHz 2-300 GHz E-field strength (V/m) 10 000 10 000 250/f 250/f 87 87 87/f1/2 28 1,375 f1/2 61 H-field strength (A/m) 3,2 × 104 3,2 × 104/f2 4 000/f 4/f 5 5 0,73/f 0,73/f 0,073 0,0037 f1/2 0,16 B-field(T) 4 × 104 4 × 104/f2 5 000/f 5/f 6,25 6,25 0,92/f 0,92/f 0,092 0,0046 f1/2 0,20 Equivalent plane wave power density Seq(W/m2) 2 f/200 10 Notes: 1. f as indicated in the frequency range column. Page 4 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RDG180807018 Test method The antenna of the product, under normal use condition is at least 20cm away from the body of the user. Warning statement ot the user for keeping 20cm separation distance and the prohibition of operating to a person has been printed on the user manual. So, this product under normal use is located on electromagnetic far field between the human body. Far Field Calculation Formula E 30PG , r G= antenna gain relative to an isotropic antenna , = elevation and azimuth angles to point of investigation r= distance from observation point to the antenna Test Data Test Mode: Transmitting(Worst case) Mode WIFI Frequency EIRP MHz 2412-2472 (dBm) 16 EIRP (W) 0.04 E-Field Strength (V/m) 5.48 E-Field Limit (V/m) 61 Result Pass Note: The distance from observation point to the antenna is 20 cm. Conclusion: Compliance Page 5 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EXHIBIT A - EUT PHOTOGRAPHS Model: TH16 EUT Top View Report No.: RDG180807018 EUT Bottom View Page 6 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT Side View Report No.: RDG180807018 EUT Side View Page 7 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT Uncover View Report No.: RDG180807018 EUT Uncover View Page 8 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT Uncover View Report No.: RDG180807018 EUT Ports View Page 9 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT Main Board Top View Report No.: RDG180807018 EUT Main Board Bottom View Page 10 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT 2.4G Wi-Fi Chip View Report No.: RDG180807018 EUT Antenna View Page 11 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) Model: TH10 EUT Top View Report No.: RDG180807018 EUT Bottom View Page 12 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT Uncover View Report No.: RDG180807018 EUT Main Board Top View Page 13 of 14 Bay Area Compliance Laboratories Corp. (Dongguan) EUT Main Board Bottom View Report No.: RDG180807018 *****END OF REPORT***** Page 14 of 14Acrobat Distiller 11.0 (Windows)