[PDF] 4SHP17LE - AC Procdn.gateway.acpro.com ⺠documents
Instructions for Allied models including: 4SHP17LE118P-51, 4SHP17LE124P-51, 4SHP17LE130P-51, 4SHP17LE136P-51, 4SHP17LE142P-51, 4SHP17LE148P-51, 4SHP17LE160P-51, 4SHP17LE High Efficiency Split System Heat Pump, 4SHP17LE, High Efficiency Split System Heat Pump, Efficiency Split System Heat Pump, Split System Heat Pump, Heat Pump, Pump
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 4 Pages, 753.26KB
Document DEVICE REPORTAC Pro 4SHPLE Heat Pump Technical Specifications4SHP17LE PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT SYSTEM HEAT PUMP UP TO 18.2 SEER & 10.6 HSPF UP TO 16.8 SEER2 & 8.5 HSPF2 COMPRESSOR ·High-efficiency scroll compressor ·R410A refrigerant ·Grommet mounted compressor for quiet operation ·Heavy-duty compressor sound blanket for quiet operation ·Internally protected against high temperature motor overload conditions CABINET ·Full metal louvered panel with 2 screws to remove for ease of coil cleaning and service ·Corner-mounted controls for easy service ·Rounded corners for safety and attractive, clean appearance ·Baked polyester paint finished over galvanized steel for maximum durability ·Removable PVC coated wire fan discharge grill ·45-degree offset gauge ports for easy service ·Removable service panel for internal access COILS ·Omniguard® total corrosion protection technology ·Enhanced tube-and-fin coil design featuring MHTTM Technology provides maximum heat transfer ·Factory tested for leak-proof construction ·Raised coil prevents debris from impeding airflow FORM NO. 4SHP17LE-100 (09/2022) DESIGN ·Designed to perform in temperatures up to 125°F ·Designed to perform in temperatures down to 0°F COMPONENTS ·Factory installed crankcase heater ·Factory installed high and low pressure switches ·Thread-on pressure switches for simple, quick service ·Filter drier shipped loose for installation flexibility ·Fan orifice for smoother airflow and sound level reduction ·Charged for 15 feet of line set ·Discharge muffler for quiet operation ·Quiet ShiftTM capable to reduce noise during defrost ·Demand defrost helps eliminate unnecessary defrost cycles ·Sealed Contactor with lugs WARRANTY ·5 year limited warranty on all parts and compressor ·Available 10 year warranty on all parts and compressor with registration* *Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions, and exclusions. NOTE: For the latest AHRI system matches, please visit www.alliedratings.com or www.AHRIdirectory.org Page 1 17 SEER SPLIT SYSTEM HEAT PUMP 4SHP17LE MODEL NUMBER GUIDE 4 SHP 17 LE 1 36 P - 51 A REFRIGERANT 4 = R410A SHP SPLIT HEAT PUMP SEER 17 TIER LE = LOUVERED ENHANCED MAJOR REVISION CODE MINOR REVISION CODE ELECTRICAL P = 1-PHASE, 208/240V, 60HZ TONNAGE 18, 24, 30, 36, 42, 48, 60 REGION RESTRICTIONS 1 = ALL REGIONS PHYSICAL AND ELECTRICAL DATA Model 4SHP17LE118P-51 4SHP17LE124P-51 4SHP17LE130P-51 4SHP17LE136P-51 4SHP17LE142P-51 4SHP17LE148P-51 4SHP17LE160P-51 Voltage/Hz/ Phase Voltage Range 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 197-253 197-253 197-253 197-253 197-253 197-253 197-253 Min. Circuit Amp. 13.6 15.1 15.6 17.8 25.9 33.9 32.5 Max. Over Current Device (amps) 20 25 25 30 40 50 50 Compressor Rated Load (amps) Locked Rotor (amps) 10.3 45.7 11.5 59.5 11.7 71.3 13.1 83.1 18.6 110.0 25.0 120.0 23.9 124.5 Outdoor Fan Motor Full Load Rated Nom. (amps) HP RPM 0.7 1/8 825 0.7 1/8 825 1.0 1/6 825 1.4 1/5 825 2.6 1/3 825 2.6 1/3 825 2.6 1/3 825 UNIT DIMENSIONS (IN.) Model Dimensions (inch) A Width B Depth C Height 4SHP17LE118P-51 29.38 31.25 43.75 4SHP17LE124P-51 29.38 31.25 43.75 4SHP17LE130P-51 29.38 31.25 33.25 4SHP17LE136P-51 35.75 37.75 33.25 4SHP17LE142P-51 35.75 37.75 37.75 4SHP17LE148P-51 35.75 37.75 37.75 4SHP17LE160P-51 35.75 37.75 43.75 Note: Dimensions listed are unit sizes w/o packaging Weights listed are unit weights with packaging Shipping Weight (lbs.) 203 203 205 230 284 284 298 Page 2 17 SEER SPLIT SYSTEM HEAT PUMP 4SHP17LE UNIT SOUND RATINGS Model Sound Power1 4SHP17LE118P-51 72 4SHP17LE124P-51 71 4SHP17LE130P-51 76 4SHP17LE136P-51 75 4SHP17LE142P-51 73 4SHP17LE148P-51 73 4SHP17LE160P-51 73 1 Rated in accordance with AHRI standard 270 (2015) 2 Rated in accordance with AHRI standard 275 (2010) 3 Based only on distance factor; other factors may change this value such as: - Unit location (reflective surfaces adjacent to the unit) - Barrier shielding sources - Sound path/elevation - Outside noise sources 3.3 Feet (1 Meter) 64 63 68 67 65 65 65 Estimated Sound Pressure (dBA)2 Approximate Distance3 6.6 Feet (2 Meters) 58 57 62 61 59 59 59 9.8 Feet (3 Meters) 54 53 58 57 55 55 55 REFRIGERATION DATA Model Refrig. Charge (Oz.)* TXV Refrigerant Line Size Suction Liquid 4SHP17LE118P-51 98 H4TXV01 3/4 3/8 4SHP17LE124P-51 96 H4TXV01 3/4 3/8 4SHP17LE130P-51 117 H4TXV01 3/4 3/8 4SHP17LE136P-51 137 H4TXV02 7/8 3/8 4SHP17LE142P-51 162 H4TXV02 7/8 3/8 4SHP17LE148P-51 146 H4TXV02 7/8 3/8 4SHP17LE160P-51 164 H4TXV03 1-1/8 3/8 * Factory charged for 15 feet of line set; adjust per installation instructions. ** Reducer fitting supplied with OD unit Outdoor Unit Connection Suction 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Indoor Unit Connection Suction 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES Indoor Model Cooling Heating Outdoor Model Evap. Coil or Air Handler3 SEER SEER2 EER EER2 AHRI Rated Capacity1 Sensible Capacity HSPF 4SHP17LE118P-51 BCE5C18M*4X 15.5 15.2 13.0 13.0 18,000 14,400 9.2 4SHP17LE124P-51 BCE5C24M*4X 15.5 14.7 13.0 12.4 23,200 17,800 9.6 4SHP17LE130P-51 BCE5C30M*4X 15.0 14.4 12.2 12.0 28,400 22,400 9.2 4SHP17LE136P-51 BCE5C36M*4X 15.5 14.7 12.5 12.4 35,600 27,000 9.6 4SHP17LE142P-51 BCE5C42M*4X 15.0 14.4 12.2 12.0 40,500 30,800 9.2 4SHP17LE148P-51 BCE5C48M*4X 15.4 14.7 12.5 12.4 47,000 35,400 9.8 4SHP17LE160P-51 BCE5C60M*4X 15.1 14.3 12.5 11.7 56,500 41,500 9.6 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (not applicable) is in the piston column then TXV is required. 3 Blower time delay relay is standard on all Allied Air Enterprises furnace and AH products. HSPF2 8.0 8.0 8.0 8.0 7.8 8.2 8.0 47° Btuh 17,900 22,200 27,800 34,000 39,000 46,500 54,000 COP 3.80 3.72 3.56 3.62 3.40 3.64 3.50 17° Btuh 11,200 14,000 18,000 22,400 25,000 30,400 35,000 COP 2.54 2.54 2.52 2.56 2.46 2.64 2.56 NOTE: For the latest AHRI system matches, please visit www.alliedratings.com or www.AHRIdirectory.org Page 3 17 SEER SPLIT SYSTEM HEAT PUMP 4SHP17LE ACCESSORIES System Accessory Where Used Kit Number Purpose Liquid Line Solenoid All models 60M52 Prevents liquid migration to the compressor especially for high liquid riser applications Low Ambient (cooling operation) All models 54M89 Enables cooling demand down to 30 °F. Will require freeze stat, CC heater and TXV Mild Ambient (heating operation) All models 11B97 Enables heating demand above 60 °F ambient Cold Weather All models 1.921145 To allow unit to operate at very low ambient conditions (older models). Board integrated feature on new models Fossil Fuel Kit (Heat Pump Only) All models 1.841185 (AFOSL500) Required for furnace with heat pump installations Hard Start 24 & 36 48 & 60 10J42 81J69 Scroll compressors usually do not require hard start; maybe needed for utility brown-out or low voltage areas Crankcase Heater 18, 24, 30 93M04 Prevents liquid migration to compressor in cold weather 36, 42, 48, 60 Factory Installed Sound Cover Factory Installed Lowers compressor sound level Loss of Charge Kit Factory Installed Protects the compressor if refrigerant charge is too low Additional System Accessories (indoor section) TXV Kit 18, 24, 30 36, 42, 48 60 H4TXV01 H4TXV02 H4TXV03 TXVs provide superior refrigerant flow control, comfort and efficiency compared to pistons Outdoor Thermostat - Electric Heat All models 10Z23 (56A87) Prevents electric heat operation above specific ambient conditions Outdoor Thermostat - Mounting Box All models 31461 Mounting box for outdoor thermostat Freezestat All models 93G35 Protects the compressor at low suction pressure conditions Overflow Switch All models 11U75 Turn the system off, if condensate water overflows due to clogged drain pipes Single Point Power Supply All models 21H39 Provide single power source in one junction box Auxiliary Blower Relay All models 85W66 Maybe required to select multiple indoor blower speeds All specifications and illustrations subject to change without notice and without incurring obligations. Form No. 4SHP17LE-100 (09/2022) 1-800-448-5872 ©2022 Allied Air Enterprises LLC, a Lennox International Inc. Company Page 4 Printed in the U.S.A.