4SHP17LE

16 hours ago — • Thread-on pressure switches for simple, quick service. • Filter drier ... * Factory charged for 15 feet of line set; adjust per installation instructions.

1 giorno fa — Outdoor Thermostat - Electric Heat. All models. 10Z23 (56A87). Prevents electric heat operation above specific ambient conditions. Outdoor Thermostat - Mounting ...

[PDF] 4SHP17LE - AC Procdn.gateway.acpro.com › documents

Instructions for Allied models including: 4SHP17LE118P-51, 4SHP17LE124P-51, 4SHP17LE130P-51, 4SHP17LE136P-51, 4SHP17LE142P-51, 4SHP17LE148P-51, 4SHP17LE160P-51, 4SHP17LE High Efficiency Split System Heat Pump, 4SHP17LE, High Efficiency Split System Heat Pump, Efficiency Split System Heat Pump, Split System Heat Pump, Heat Pump, Pump

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 4 Pages, 753.26KB

Document DEVICE REPORTAC Pro 4SHPLE Heat Pump Technical Specifications
4SHP17LE
PRODUCT SPECIFICATIONS

HIGH EFFICIENCY SPLIT SYSTEM HEAT PUMP UP TO 18.2 SEER & 10.6 HSPF UP TO 16.8 SEER2 & 8.5 HSPF2

COMPRESSOR
·High-efficiency scroll compressor ·R410A refrigerant ·Grommet mounted compressor for quiet operation ·Heavy-duty compressor sound blanket for quiet
operation ·Internally protected against high temperature motor
overload conditions
CABINET
·Full metal louvered panel with 2 screws to remove for ease of coil cleaning and service
·Corner-mounted controls for easy service ·Rounded corners for safety and attractive, clean
appearance ·Baked polyester paint finished over galvanized steel for
maximum durability ·Removable PVC coated wire fan discharge grill ·45-degree offset gauge ports for easy service ·Removable service panel for internal access
COILS
·Omniguard® total corrosion protection technology ·Enhanced tube-and-fin coil design featuring MHTTM
Technology provides maximum heat transfer ·Factory tested for leak-proof construction ·Raised coil prevents debris from impeding airflow

FORM NO. 4SHP17LE-100 (09/2022)
DESIGN
·Designed to perform in temperatures up to 125°F ·Designed to perform in temperatures down to 0°F
COMPONENTS
·Factory installed crankcase heater ·Factory installed high and low pressure switches ·Thread-on pressure switches for simple, quick service ·Filter drier shipped loose for installation flexibility ·Fan orifice for smoother airflow and sound level
reduction ·Charged for 15 feet of line set ·Discharge muffler for quiet operation ·Quiet ShiftTM capable to reduce noise during defrost ·Demand defrost helps eliminate unnecessary defrost
cycles ·Sealed Contactor with lugs
WARRANTY
·5 year limited warranty on all parts and compressor ·Available 10 year warranty on all parts and
compressor with registration*
*Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions, and exclusions.
NOTE: For the latest AHRI system matches, please visit www.alliedratings.com or www.AHRIdirectory.org

Page 1

17 SEER SPLIT SYSTEM HEAT PUMP

4SHP17LE

MODEL NUMBER GUIDE

4 SHP 17 LE 1 36 P - 51 A

REFRIGERANT 4 = R410A
SHP SPLIT HEAT PUMP
SEER 17
TIER LE = LOUVERED ENHANCED

MAJOR REVISION CODE
MINOR REVISION CODE
ELECTRICAL P = 1-PHASE, 208/240V, 60HZ
TONNAGE 18, 24, 30, 36, 42, 48, 60
REGION RESTRICTIONS 1 = ALL REGIONS

PHYSICAL AND ELECTRICAL DATA

Model
4SHP17LE118P-51 4SHP17LE124P-51 4SHP17LE130P-51 4SHP17LE136P-51 4SHP17LE142P-51 4SHP17LE148P-51 4SHP17LE160P-51

Voltage/Hz/ Phase

Voltage Range

208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1

197-253 197-253 197-253 197-253 197-253 197-253 197-253

Min. Circuit Amp.
13.6 15.1 15.6 17.8 25.9 33.9 32.5

Max. Over Current Device (amps)
20 25 25 30 40 50 50

Compressor

Rated Load (amps)

Locked Rotor (amps)

10.3

45.7

11.5

59.5

11.7

71.3

13.1

83.1

18.6

110.0

25.0

120.0

23.9

124.5

Outdoor Fan Motor

Full Load Rated Nom.

(amps)

HP

RPM

0.7

1/8

825

0.7

1/8

825

1.0

1/6

825

1.4

1/5

825

2.6

1/3

825

2.6

1/3

825

2.6

1/3

825

UNIT DIMENSIONS (IN.)

Model

Dimensions (inch)

A Width

B Depth

C Height

4SHP17LE118P-51

29.38

31.25

43.75

4SHP17LE124P-51 29.38

31.25

43.75

4SHP17LE130P-51 29.38

31.25

33.25

4SHP17LE136P-51

35.75

37.75

33.25

4SHP17LE142P-51

35.75

37.75

37.75

4SHP17LE148P-51

35.75

37.75

37.75

4SHP17LE160P-51 35.75

37.75

43.75

Note: Dimensions listed are unit sizes w/o packaging Weights listed are unit weights with packaging

Shipping Weight (lbs.)
203 203 205 230 284 284 298

Page 2

17 SEER SPLIT SYSTEM HEAT PUMP

4SHP17LE

UNIT SOUND RATINGS

Model

Sound Power1

4SHP17LE118P-51

72

4SHP17LE124P-51

71

4SHP17LE130P-51

76

4SHP17LE136P-51

75

4SHP17LE142P-51

73

4SHP17LE148P-51

73

4SHP17LE160P-51

73

1 Rated in accordance with AHRI standard 270 (2015) 2 Rated in accordance with AHRI standard 275 (2010) 3 Based only on distance factor; other factors may change this value such as:
- Unit location (reflective surfaces adjacent to the unit) - Barrier shielding sources - Sound path/elevation - Outside noise sources

3.3 Feet (1 Meter)
64 63 68 67 65 65 65

Estimated Sound Pressure (dBA)2 Approximate Distance3 6.6 Feet (2 Meters) 58 57 62 61 59 59 59

9.8 Feet (3 Meters)
54 53 58 57 55 55 55

REFRIGERATION DATA

Model

Refrig. Charge (Oz.)*

TXV

Refrigerant Line Size

Suction

Liquid

4SHP17LE118P-51

98

H4TXV01

3/4

3/8

4SHP17LE124P-51

96

H4TXV01

3/4

3/8

4SHP17LE130P-51

117

H4TXV01

3/4

3/8

4SHP17LE136P-51

137

H4TXV02

7/8

3/8

4SHP17LE142P-51

162

H4TXV02

7/8

3/8

4SHP17LE148P-51

146

H4TXV02

7/8

3/8

4SHP17LE160P-51

164

H4TXV03

1-1/8

3/8

* Factory charged for 15 feet of line set; adjust per installation instructions. ** Reducer fitting supplied with OD unit

Outdoor Unit Connection

Suction 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8

Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8

Indoor Unit Connection

Suction 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8

Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8

COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES

Indoor Model

Cooling

Heating

Outdoor Model

Evap. Coil or Air Handler3

SEER SEER2 EER

EER2

AHRI Rated Capacity1

Sensible Capacity

HSPF

4SHP17LE118P-51 BCE5C18M*4X 15.5

15.2 13.0 13.0

18,000

14,400

9.2

4SHP17LE124P-51 BCE5C24M*4X 15.5

14.7 13.0 12.4

23,200

17,800

9.6

4SHP17LE130P-51 BCE5C30M*4X 15.0 14.4 12.2 12.0 28,400 22,400

9.2

4SHP17LE136P-51 BCE5C36M*4X 15.5

14.7 12.5 12.4 35,600

27,000

9.6

4SHP17LE142P-51 BCE5C42M*4X 15.0

14.4 12.2 12.0 40,500 30,800

9.2

4SHP17LE148P-51 BCE5C48M*4X 15.4

14.7 12.5 12.4

47,000

35,400

9.8

4SHP17LE160P-51 BCE5C60M*4X 15.1

14.3 12.5 11.7

56,500

41,500

9.6

Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (not applicable) is in the piston column then TXV is required. 3 Blower time delay relay is standard on all Allied Air Enterprises furnace and AH products.

HSPF2
8.0 8.0 8.0 8.0 7.8 8.2 8.0

47°

Btuh
17,900 22,200 27,800 34,000 39,000 46,500 54,000

COP
3.80 3.72 3.56 3.62 3.40 3.64 3.50

17°

Btuh
11,200 14,000 18,000 22,400 25,000 30,400 35,000

COP
2.54 2.54 2.52 2.56 2.46 2.64 2.56

NOTE: For the latest AHRI system matches, please visit www.alliedratings.com or www.AHRIdirectory.org
Page 3

17 SEER SPLIT SYSTEM HEAT PUMP

4SHP17LE

ACCESSORIES

System Accessory

Where Used

Kit Number

Purpose

Liquid Line Solenoid

All models

60M52

Prevents liquid migration to the compressor especially for high liquid riser applications

Low Ambient (cooling operation)

All models

54M89

Enables cooling demand down to 30 °F. Will require freeze stat, CC heater and TXV

Mild Ambient (heating operation)

All models

11B97

Enables heating demand above 60 °F ambient

Cold Weather

All models

1.921145

To allow unit to operate at very low ambient conditions (older models). Board integrated feature on new models

Fossil Fuel Kit (Heat Pump Only)

All models

1.841185 (AFOSL500)

Required for furnace with heat pump installations

Hard Start

24 & 36 48 & 60

10J42 81J69

Scroll compressors usually do not require hard start; maybe needed for utility brown-out or low voltage areas

Crankcase Heater

18, 24, 30

93M04

Prevents liquid migration to compressor in cold weather

36, 42, 48, 60 Factory Installed

Sound Cover

Factory Installed

Lowers compressor sound level

Loss of Charge Kit

Factory Installed

Protects the compressor if refrigerant charge is too low

Additional System Accessories (indoor section)

TXV Kit

18, 24, 30 36, 42, 48
60

H4TXV01 H4TXV02 H4TXV03

TXVs provide superior refrigerant flow control, comfort and efficiency compared to pistons

Outdoor Thermostat - Electric Heat All models

10Z23 (56A87)

Prevents electric heat operation above specific ambient conditions

Outdoor Thermostat - Mounting Box All models

31461

Mounting box for outdoor thermostat

Freezestat

All models

93G35

Protects the compressor at low suction pressure conditions

Overflow Switch

All models

11U75

Turn the system off, if condensate water overflows due to clogged drain pipes

Single Point Power Supply

All models

21H39

Provide single power source in one junction box

Auxiliary Blower Relay

All models

85W66

Maybe required to select multiple indoor blower speeds

All specifications and illustrations subject to change without notice and without incurring obligations.
Form No. 4SHP17LE-100 (09/2022)

1-800-448-5872
©2022 Allied Air Enterprises LLC, a Lennox International Inc. Company Page 4

Printed in the U.S.A.



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)

Search Any Device: