HD 271 S1
Allo
FCC MPE(Portable) Report
Dongguan Ruige Electronics Co., LTD M95 Bluetooth headphones 2BC8W-M95 2BC8WM95 m95
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 9 Pages, 1.03MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7961866RF Exposure Evaluation Report Application No.: Applicant: Address of Applicant: EUT Description: Model No.: FCC ID: Power Supply (Charging Box): Power Supply (Earphone Box): Standards: Trade Mark: Date of Receipt: Date of Test: Date of Issue: Test Result: DNT2412130223R5714-07737 Dongguan Ruige Electronics Co., LTD 2F, Building 3, No. 24, Puxinhu Xincheng Road, Tangxia Town, Dongguan City, Guangdong Province, China Bluetooth headphones M95, M94, M96 2BC8W-M95 Input:DC 5V DC 3.7V By 600mAh Rechargeable Li-ion Battery 3.7V By 40mAh Rechargeable Li-ion Battery 47 CFR Part 2.1093 FCC KDB 447498 D04 v01 / 2024/12/07 2024/12/08 to 2025/01/06 2025/01/07 PASS Prepared By: (Testing Engineer) Reviewed By: (Project Engineer) Approved By: (Manager) Note: If there is any objection to the results in this report, please submit a written inquiry to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp, and is issued by the company in accordance with the requirements of the "Conditions of Issuance of Test Reports" printed in the attached page. Unless otherwise stated, the results presented in this report only apply to the samples tested this time. Partial reproduction of this report is not allowed unless approved by the Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 company in writing. DateJanuary 8, 2025 Page2 / 9 Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 Report Revise Record Report Version V2.0 Revise Time / Issued Date Jan.08, 2024 DateJanuary 8, 2025 Page3 / 9 Valid Version Valid Notes Original Report Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 DateJanuary 8, 2025 Contents Page4 / 9 RF EXPOSURE EVALUATION REPORT ............................................................................................................................................. 1 1 GENERAL INFORMATION .................................................................................................................................................................. 5 1.1 TEST LOCATION .................................................................................................................................................................................5 1.2 GENERAL DESCRIPTION OF EUT ..................................................................................................................................................... 5 2 RF EXPOSURE EVALUATION ............................................................................................................................................................6 2.1 RF EXPOSURE COMPLIANCE REQUIREMENT .................................................................................................................................. 6 Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 1 General Information DateJanuary 8, 2025 Page5 / 9 1.1 Test Location Company: Address: Test engineer: Dongguan DN Testing Co., Ltd No. 1, West Fourth Street, South Xinfa Road, Wusha Liwu, Chang an Town, Dongguan City, Guangdong P.R.China Wayne Lin 1.2 General Description of EUT Manufacturer: Address of Manufacturer: EUT Description: Test Model No.: Additional Model(s): Chip Type: Serial number: Trade Mark: Hardware Version: Software Version: Sample Type: Antenna Type: Antenna Gain: Dongguan Ruige Electronics Co., LTD 2F, Building 3, No. 24, Puxinhu Xincheng Road, Tangxia Town, Dongguan City, Guangdong Province, China Bluetooth headphones M95 M94, M96 AB5756T PR2412130223R5714 / V1.0 V1.0 Portable Device, Module, Mobile Device External, Integrated Provided by applicant 2.7dBi Remark: *All models are just color differences, motherboard, PCB circuit board, chip, electronic components, appearance all the same. *Since the above data and/or information is provided by the applicant relevant results or conclusions of this report are only made for these data and/or information , DNT is not responsible for the authenticity, integrity and results of the data and information and/or the validity of the conclusion. Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 2 RF Exposure Evaluation 2.1 RF Exposure Compliance Requirement 2.1.1 Limits DateJanuary 8, 2025 Page6 / 9 Human exposure to RF emissions from portable devices (47 CFR §2.1093), as defined by the FCC, must be evaluated with respect to the FCC-adopted limits for SAR. Evaluation of mobile devices, as defined by the FCC, may also be performed with respect to SAR limits, but in such cases it is usually simpler and more cost-effective to evaluate compliance with respect to field strength or power density limits. For certain devices that are designed to be used in both mobile and portable configurations similar to those described in 47 CFR §2.1091(d)(4), such as certain desktop phones and wireless modem modules, compliance for mobile configurations is also satisfied when the same device is evaluated for SAR compliance in portable configurations. Refer to 47 CFR §2.1093: A portable device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that the RF source's radiating structure(s) is/are within 20 centimeters of the body of the user. Evaluation of compliance with the exposure limits in § 1.1310 of this chapter, and preparation of an EA if the limits are exceeded, is necessary for portable devices having single RF sources with more than an available maximum time-averaged power of 1 mW, more than the ERP listed in Table 1 to § 1.1307(b)(3)(i)(C), or more than the Pth in the following formula, whichever is greater. The following formula shall only be used in conjunction with portable devices not exempt by § 1.1307(b)(3)(i)(C) at distances from 0.5 centimeters to 20 centimeters and frequencies from 0.3 GHz to 6 GHz. Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 DateJanuary 8, 2025 Page7 / 9 The test exclusions are applicable only when the minimum test separation distance is 50 mm and for transmission frequencies between 300 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 2.1.2 Test Procedure DateJanuary 8, 2025 Page8 / 9 Software provided by client enabled the EUT to transmit data at lowest, middle and highest channel individually 2.1.3 EUT RF Exposure Evaluation Left Earphone: Mode Fre (MHz) Peak Conducted output Power (dBm) Target power (dBm) Antenna Gain (dBi) Max. E.R.P (dBm) Max. Target power (mW) SAR Test Exemption Limit (mW) 2402 1.96 1±1 2.7 2.55 1.799 3 GFSK 2441 2.24 2±1 2.7 3.55 2.265 3 2480 -0.22 0±1 2.7 1.55 1.429 3 2402 1.97 1±1 /4- 2441 2.26 2±1 DQPSK 2480 -0.43 0±1 2.7 2.55 1.799 3 2.7 3.55 2.265 3 2.7 1.55 1.429 3 2402 1.78 1±1 2.7 2.55 1.799 3 8 DPSK 2441 2.09 2±1 2.7 3.55 2.265 3 2480 -0.31 0±1 2.7 1.55 1.429 3 Right Earphone: Mode Fre (MHz) GFSK 2402 2441 2480 Peak Conducted output Power (dBm) 1.16 1.80 -0.13 Target power (dBm) Antenna Gain (dBi) Max. E.R.P (dBm) 1±1 2.7 2.55 1±1 2.7 2.55 0±1 2.7 1.55 Max. Target power (mW) 1.799 1.799 1.429 SAR Test Exemption Limit (mW) 3 3 3 2402 1.81 1±1 /4- 2441 2.54 2±1 DQPSK 2480 0.55 0±1 2.7 2.55 1.799 3 2.7 3.55 2.265 3 2.7 1.55 1.429 3 2402 2.45 2±1 2.7 3.55 2.265 3 8 DPSK 2441 3.00 3±1 2.7 4.55 2.851 3 2480 1.04 1±1 2.7 2.55 1.799 3 Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected] Report No.: DNT2412130223R5714-07737 DateJanuary 8, 2025 Page9 / 9 Note: 1. E.R.P=Conducted output Power+Antenna Gain -2.15. 2. SAR Test Exclusion Thresholds is 3mW for separation distance 5mm. Therefore, SAR test is not required. The End Report Dongguan DN Testing Co., Ltd. Add: No. 1, West Fourth Street, Xingfa South Road, Wusha Community, Chang 'an Town, Dongguan City, Guangdong P.R.China Web: www.dn-testing.com Tel:+86-769-88087383 E-mail: [email protected]
Related FCC IDs:
- 2BC8W-M95 - Dongguan Ruige Electronics Co., LTD Bluetooth headphones [-M95] WPS 文字