According to §15
Benjamin
RF Exposure Info
Sariana LLC ST-LKCF VEGAN-LEATHER FINDALL KEYCHAIN ZE9-ST-LKCF ZE9STLKCF st lkcf
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 1 Pages, 79.88KB
Document DEVICE REPORTGetApplicationAttachment.html?id=8199753FCC ID: ZE9-ST-LKCF Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission's guidelines. According to KDB447498 D01 General RF Exposure Guidance V06 The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[f(GHZ)] 3.0 for 1-g SAR and 7.5 for 10-g extremity SAR, where: · f(GHZ) is the RF channel transmit frequency in GHz · Power and distance are rounded to the nearest mW and mm before calculation · The result is rounded to one decimal place for comparison When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. BT Conduct Max Channel ed Conducte Tune-up tune-up Modulation Freq. power d power power power (GHz) (dBm) (mW) (dBm) (dBm) GFSK(1M bps) GFSK(2M bps) 2.480 2.480 -1.1 -1.08 0.78 0.78 -1±1 -1±1 0.00 0.00 Max tune-up power (mW) 1.00 1.00 Result SAR Distance (mm) calculatio Exclusion n threshold <5 0.31496 3.00 <5 0.31496 3.00 SAR test exclusion YES YES Conclusion: For the max result : 0.314963, the SAR testing is not required.
Related FCC IDs:
- ZE9-ST-LKCF - Sariana LLC VEGAN-LEATHER FINDALL KEYCHAIN [-ST-LKCF] Microsoft Word 2016