AN EFFICIENT, RELIABLE SYSTEM THAT'S IDEAL ... - Carrier

4 dic 2022 — KEY FEATURES. Minimal Footprint. A low-profile, unobtrusive outdoor unit makes this system an ideal option for homes with zero lot lines or limited.

Datasheet for TEMPSTAR models including: DLCURA, DLCURA Ductless Air Conditioner Outdoor Unit, Ductless Air Conditioner Outdoor Unit, Air Conditioner Outdoor Unit, Outdoor Unit

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 4 Pages, 244.71KB

Document DEVICE REPORTDLS-013-TS-00
DLCURA OUTDOOR UNIT DLFUAA AIR HANDLER
SYSTEM FEATURES · Anti-corrosive fin coating · Traditional unitary line set sizes · Quiet operation
OUTDOOR FEATURES · Factory installed basepan heater · Factory installed crankcase heater · Low voltage controls · 24V Interface pre-installed · Standard heat and high
heat options · Auto-restart function · Condenser high temp protection
INDOOR FEATURES · Modes: Cool, Heat, Dry, Fan, Auto · 4-way installation
(Up flow, Down flow, Right, Left) · New aluminum coil · Automatic airflow technology with
static pressure up to 0.8 inWG · Less than 2% air leakage · Easy maintenance

AN EFFICIENT, RELIABLE SYSTEM THAT'S IDEAL FOR SMALL OUTDOOR SPACES
Heat Pump with Basepan Heater Inverter-driven, variable speed, rotary compressor Up to 18.0 SEER2 Up to 10.0 HSPF2 Sizes: 18 / 24 / 30 / 36 / 48 / 60
KEY FEATURES Minimal Footprint A low-profile, unobtrusive outdoor unit makes this system an ideal option for homes with zero lot lines or limited outdoor space. Whole-Home Solution This versatile, energy efficient system can be easily retrofitted to combine with existing connections, providing an efficiency upgrade for your entire home.
CONTROLS Built-in 24V Interface for third-party thermostat control
OPTIONAL ACCESSORIES Electric heater kit 7-day programmable wired controller
LIMITED WARRANTY* 10-year limited to original purchaser on compressor and parts upon timely registration. Otherwise, 5 years.
*For residential applications. See warranty for full details.

DLCURA OUTDOOR UNIT

SPECIFICATIONS:

Outdoor Size Outdoor Model

Voltage, Phase, Cycle MCA Recommended Fuse Size MOPA - Fuse Rating Short Circuit Current Rating (SCCR)

V/Ph/Hz A. A. A. kA

Cooling Outdoor DB Min - Max Heating Outdoor DB Min - Max

° F(° C) ° F(° C)

Total Piping Length Piping Lift* Pipe Connection Size - Liquid Pipe Connection Size - Suction

ft (m) ft (m) in (mm) in (mm)

Refrigerant Type Charge Add'l Refrigerant (between Std & Max Piping Lngths) Metering Device

lbs (kg) Oz/ft (g/m)

Face Area No. Rows Fins per inch Circuits

Sq. Ft.

Type Model Oil Type Oil Charge Rated Current

Fl. Oz. RLA

Airflow

CFM

Sound Pressure

dB(A)

* Condensing unit above or below indoor unit

DLCURA Outdoor Unit

Heat Pump (Standard Heat)

System

1.5T

2T

2.5T

DLCURAH18AAK

DLCURAH24AAK

DLCURAH30AAK

Electrical

208/230-1-60

208/230-1-60

208/230-1-60

16

19

20

20

20

25

20

30

35

2.4

2.4

2.4

Operating Range

5~130 (-15~55)

5~130 (-15~55)

5~130 (-15~55)

-5~86 (-15~30)

-5~86 (-15~30)

-5~86 (-15~30)

Piping

98 (30)

164 (50)

164 (50)

65 (20)

82 (25)

82 (25)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

3/4 (19)

3/4 (19)

3/4 (19)

Refrigerant

R410A

R410A

R410A

3.53 (1.6)

4.63 (2.1)

6.72 (3.05)

0.69 (65)

0.69 (65)

0.69 (65)

EEV

EEV

EEV

Outdoor Coil

5

5.9

8.18

2

2

2.6

20

20

18

4

6

6

Compressor

Rotary Inverter

Rotary Inverter

Rotary Inverter

KSN140D21UFZ

KTM240D57UMT

KTF250D22UMT

VG74

VG74

VG74

14.9

22.7

22.7

9

14

16

Airflow & Sound

1,450

1,765

3,000

54

60

62

3T DLCURAH36AAK
208/230-1-60 24 25 40 2.4
5~130 (-15~55) -5~86 (-15~30)
213 (65) 98 (30) 3/8 (9.52) 3/4 (19)
R410A 8.16 (3.7) 0.69 (65)
EEV
8.14 3 18 6
Rotary Inverter KTF250D22UMT
VG74 22.7 17.6
2,235 61

4T DLCURAH48AAK
208/230-1-60 34 35 50 2.4
5~130 (-15~55) -5~86 (-15~30)
213 (65) 98 (30) 3/8 (9.52) 3/4 (19)
R410A 10.4 (4.7) 0.69 (65)
EEV
13.53 2 18 8
Rotary Inverter KTQ420D1UMU
VG74 47.3 24
4,500 59

5T DLCURAH60AAK
208/230-1-60 34 35 60 2.4
5~130 (-15~55) -5~86 (-15~30)
213 (65) 98 (30) 3/8 (9.52) 7/8 (22)
R410A 10.8 (4.9) 0.69 (65)
EEV
13.36 3 18 14
Rotary Inverter KTQ420D1UMU
VG74 47.3 24.6
4,412 61

PERFORMANCE:
Outdoor Size
Indoor Model Cooling Rated Capacity Cooling Cap. Range Min - Max SEER EER Heating Rated Capacity (47° F) Heating Rated Capacity (17° F) Heating Rated Capacity (5° F) Heating Cap. Range Min - Max HSPF COP (47° F) COP (17° F) COP (5° F)
Cooling Rated Capacity Cooling Cap. Range Min - Max SEER2 EER2 Heating Rated Capacity (47° F) Heating Rated Capacity (17° F) Heating Rated Capacity (5° F) Heating Cap. Range Min - Max HSPF2 COP (47° F) COP (17° F) COP (5° F)

Btu/h Btu/h
Btu/h Btu/h Btu/h Btu/h
W/W W/W W/W
Btu/h Btu/h
Btu/h Btu/h Btu/h Btu/h
W/W W/W W/W

DLCURA Outdoor Unit

Heat Pump (Standard Heat)

1.5T

2T

M Ratings

18K

24K

18,000

24,000

5400~18700

7500~26000

19.0

19.4

11.1

11.3

18,000

26,000

12,000

21,000

9,500

17,000

5600~18700

5600~30000

10.8

11.3

3.49

3.54

2.70

2.75

1.85

1.75

M1 Ratings

18,000

24,000

5400~18700

7500~26000

16.0

17.0

10.9

10.5

18,000

26,000

11,500

20,700

10,000

17,000

5600~18700

5600~30000

8.8

9.2

3.50

3.45

2.75

2.40

1.90

2.00

2.5T
30K 30,000 9500~33000 19.5 10.9 31,000 20,000 20,000 12200~32000 10.3 3.19
2.30 1.95
30,000 9500~33000
17.3 10.6 31,000 20,000 17,800 12200~32000 8.5 3.25 2.45 1.75

3T
36K 36,000 8900~38900 18.0 10.4 36,000 20,400 21,000 6000~36400
9.1 3.02 2.25 1.80
36,000 8900~38900
16.9 10.1 36,000 20,500 21,000 6000~36400 8.2 3.39 2.40 1.88

4T
48K 47,000 10500~48000 17.3
9.3 55,000 37,000 27,000 11700~57000 10.0 3.00 2.00 1.72
47,000 10500~48000
15.8 8.8 55,000 36,500 36,500 11700~57000 9.4 3.15 2.30 1.98

5T
60K 57,000 4400~60200 18.0 10.3 60,000 37,000 29,000 11400~63100
9.2 3.55 2.45 1.80
57,000 4400~60200
14.7 8.8 60,000 36,000 34,800 11400~63100 8.5 3.45 2.35 1.89

DLCURA OUTDOOR UNIT

SPECIFICATIONS:

Outdoor Size Outdoor Model

Voltage, Phase, Cycle MCA Recommended Fuse Size MOCP - Fuse Rating Short Circuit Current Rating (SCCR)

V/Ph/Hz A. A. A. kA

Cooling Outdoor DB Min - Max Heating Outdoor DB Min - Max

° F(° C) ° F(° C)

Total Piping Length Piping Lift* Pipe Connection Size - Liquid Pipe Connection Size - Suction

ft (m) ft (m) in (mm) in (mm)

Refrigerant Type Charge Add'l Refrigerant (between Std & Max Piping Lngths) Metering Device

lbs (kg) Oz/ft (g/m)

Face Area No. Rows Fins per inch Circuits

Sq. Ft.

Type Model Oil Type Oil Charge Rated Current

Fl. Oz. RLA

Airflow

CFM

Sound Pressure

dB(A)

DLCURA Outdoor Unit

Heat Pump (High Heat)

System

1.5T - HH

2T - HH

DLCURAH18ABK DLCURAH24ABK

Electrical

208/230-1-60

208/230-1-60

16

20.5

20

25

20

35

2.4

2.4

Operating Range

-22~130 (-30~55) -22~130 (-30~55)

-22~86 (-30~30) -22~86 (-30~30)

Piping

98 (30)

164 (50)

65 (20)

82 (25)

3/8 (9.52)

3/8 (9.52)

3/4 (19)

3/4 (19)

Refrigerant

R410A

R410A

5.07 (2.3)

6.39 (2.9)

0.69 (65)

0.69 (65)

EEV

EEV

Outdoor Coil

5.9

8.16

2

2

20

20

6

4

Compressor

Rotary Inverter Rotary Inverter

KTM240D57UMT KTM240D57UMT

VG74

VG74

22.7

22.7

10

15

Airflow & Sound

1,279

3,000

58

64

2.5T - HH DLCURAH30ABK
208/230-1-60 23 25 35 2.4
-22~130 (-30~55) -22~86 (-30~30)
164 (50) 82 (25) 3/8 (9.52) 3/4 (19)
R410A 8.38 (3.8) 0.69 (65)
EEV
8.16 3 20 4
Rotary Inverter KTF310D43UMT
VG74 33.8 16.5
3,000 62

3T - HH DLCURAH36ABK
208/230-1-60 41 45 50 2.4
-22~130 (-30~55) -22~86 (-30~30)
213 (65) 98 (30) 3/8 (9.52) 3/4 (19)
R410A 10.36 (4.7) 0.69 (65)
EEV
14.08 1.6 18 8
Rotary Inverter EAPQ420D1UMUA
VG74 49.4 32
4,500 64

4T - HH DLCURAH48ABK
208/230-1-60 42 45 50 2.4
-22~130 (-30~55) -22~86 (-30~30)
213 (65) 98 (30) 3/8 (9.52) 3/4 (19)
R410A 10.58 (4.8) 0.69 (65)
EEV
13.53 2 18 8
Rotary Inverter EAPQ420D1UMUA
VG74 49.4 33
4,412 64

5T - HH DLCURAH60ABK
208/230-1-60 42 45 60 2.4
-22~130 (-30~55) -22~86 (-30~30)
213 (65) 98 (30) 3/8 (9.52) 7/8 (22)
R410A 10.58 (4.8) 0.69 (65)
EEV
13.29 2.6 20 10
Rotary Inverter EAPQ440D1UMUA
VG75 43.96
28
4,500 64

* Condensing unit above or below indoor unit

PERFORMANCE:
Outdoor Size
Indoor Model Energy Star Cooling Rated Capacity Cooling Cap. Range Min - Max SEER EER Heating Rated Capacity (47° F) Heating Rated Capacity (17° F) Heating Rated Capacity (5° F) Heating Cap. Range Min - Max HSPF COP (47° F) COP (17° F) COP (5° F)
Cooling Rated Capacity Cooling Cap. Range Min - Max SEER2 EER2 Heating Rated Capacity (47° F) Heating Rated Capacity (17° F) Heating Rated Capacity (5° F) Heating Cap. Range Min - Max HSPF2 COP (47° F) COP (17° F) COP (5° F)

Btu/h Btu/h
Btu/h Btu/h Btu/h Btu/h
W/W W/W W/W
Btu/h Btu/h
Btu/h Btu/h Btu/h Btu/h
W/W W/W W/W

DLCURA Outdoor Unit

Heat Pump (High Heat)

1.5T - HH

2T - HH

M Ratings

18K

24K

YES

YES

18,000

24,000

6900~21000

6400~27000

20.0

20.0

12.5

12.5

19,000

24,000

13,500

19,200

19,000

24,000

2800~21000

10100~31000

11.0

12.0

3.59

3.45

2.75

2.70

1.90

1.80

M1 Ratings

18,000

24,000

6900~21000

6400~27000

18.0

17.4

12.4

11.7

19,000

24,000

13,000

18,600

16,500

22,700

2800~21000

10100~31000

9.3

10.0

3.60

3.40

2.50

2.40

2.00

1.85

2.5T - HH
30K NO 30,000 10400~33600 18.0 11 33,000 21,000 28,500 12000~37000 10.5 3.48 2.60 1.95
30,000 10400~33600
16.2 9.8 33,000 20,400 24,100 12000~37000 8.9 3.30 2.30 1.80

3T - HH
36K NO 36,000 12000~47400 18.0 10.5 41,500 30,400 43,300 9000~57200 10.5 3.45 2.65 1.80
36,000 12000~47400
15.8 9.8 40,000 29,500 34,500 9000~57200 9.5 3.35 2.40 1.95

4T - HH
48K NO 47,000 18000~48000 16.0 8.5 50,000 36,000 47,000 20000~55000 10.0 3.00 2.30 1.88
47,000 18000~48000
15.6 8.2 50,000 35,000 46,000 20000~55000 9.4 3.15 2.30 1.90

5T - HH
60K NO 55,000 18000~56000 16.4 9 59,000 42,000 50,000 20000~68000 10.5 3.50 2.60 1.96
55,000 18000~56000
15.0 8.5 59,000 42,000 50,000 20000~68000 9.0 3.00 2.60 1.96

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

DLFUAA AIR HANDLER

SPECIFICATIONS:

Indoor Size Indoor Model

18K DLFUAAH18XAK

Voltage, Phase, Cycle MCA Recommended Fuse Size MOPA - Fuse Rating

V/Ph/Hz A. A. A.

208/230-1-60 2.5 5 15

Cooling Indoor DB Min - Max ° F(° C) Heating Indoor DB Min - Max ° F(° C)

60~90 (16~32) 32~86(0~30)

Pipe Connection Size - Liquid in (mm) Pipe Connection Size - Suction in (mm)

3/8 (9.52) 3/4 (19)

Refrigerant Type Metering Device

R410A EEV

Face Area No. Rows Fins Per Inch Circuits

Sq. Ft.

3

3

20

6

Number of Fan Speeds (low/med/high/turbo)

Airflow (lowest to highest)

CFM

Cooling Sound Pressure (low to high)

dB(A)

Heating Sound Pressure (low to high)

dB(A)

Max Static Pressure

In. W.G.

Field Drain Pipe Size O.D.

in (mm)

4 488/529/576/618 30.5/31.4/33.4/35.2
29.8/30.7/34.0/35.3 0.8
3/4 (19.1)

DLFUAA Air Handler

Heat Pump (High Heat)

System

24K

30K

DLFUAAH24XAK

DLFUAAH30XAK

Electrical

208/230-1-60

208/230-1-60

4

4.5

5

5

15

15

Operating Range

60~90 (16~32)

60~90 (16~32)

32~86(0~30)

32~86(0~30)

Piping

3/8 (9.52)

3/8 (9.52)

3/4 (19)

3/4 (19)

Refrigerant

R410A

R410A

EEV

EEV

Indoor Coil

3

3.8

3

4

20

20

6

10

Airflow & Sound

4

4

629/694/759/824

712/806/894/1088

33.6/36.6/38.7/40.4

37.7/41.3/43.0/45.6

32.4/36.9/39.6/40.6
0.8 3/4 (19.1)

29.5/36.9/43.0/43.2
0.8 3/4 (19.1)

36K DLFUAAH36XAK
208/230-1-60 5 10 15
60~90 (16~32) 32~86(0~30)
3/8 (9.52) 3/4 (19)
R410A EEV
3.8 4 20 10
4 865/971/1082/1188 40.2/43.2/45.7/48.0
35.6/40.7/46.8/46.7 0.8
3/4 (19.1)

48K DLFUAAH48XAK

60K DLFUAAH60XAK

208/230-1-60 7.5 10 15

208/230-1-60 9 10 15

60~90 (16~32) 32~86(0~30)

60~90 (16~32) 32~86(0~30)

3/8 (9.52) 3/4 (19)

3/8 (9.52) 7/8 (22)

R410A EEV

R410A EEV

3.8

4.88

4

5

20

20

10

14

4 906/1094/1282/1471
42.5/47.1/50.3/54.0

4 1135/1359/1582/1806
45.0/49.1/52.1/55.3

43.7/46.8/50.2/52.7
0.8 3/4 (19.1)

43.4/48.0/53.0/60.5
0.8 3/4 (19.1)

A Proud Member of the Carrier Family
Tempstar.com | PO Box 128 Lewisburg, TN 37091 | ©2023 Carrier. All Rights Reserved. Midea is a registered trademark owned by Midea Group Co., Ltd. Part No. DLS-013-TS-00 | 1/2023



References

Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)

Search Any Device: