RF Exposure Info

Vermeer Manufacturing Company VTSHUB1 Digital Transmission System 2AXF5-VTSHUB1 2AXF5VTSHUB1 vtshub1

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 1 Pages, 220.30KB

Document DEVICE REPORTGetApplicationAttachment.html?id=6552108
FCC IC SAR Eclusion
4.3.1. Standalone SAR test exclusion considerations
100 MHz to 6 GHz at separation distance less than or equal to 50 mm

SAR Test Exclusion Calculator

Insert values in yellow highlighted boxes to determine SAR Exclusion

Max Power

2 mW

Min Separation

5 mm

When the minimum test separation distance is < 5 mm, a distance of 5 mm is

Frequency

0.917 GHz

applied to determine SAR test exclusion.

Answer

0.4 Must be less than or equal to 3.0 for SAR Exclusion

KDB 628591 D01 TCB Exclusion List v14 TCBs are excluded from granting if: General Population: The Answer is equal to or greater than 24 (8x threshold) Controlled Use: The Answer is equal to or greater than 60 (20x threshold) and, when published RF exposure KDB procedures are not established for SAR testing or when SAR data is not provided to support compliance.

Please also note the following: [FCC KDB quote] These test exclusion conditions are based on source-based
time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer
surface. [End quote]

Rogers Labs, Inc. 4405 West 259th Terrace
Louisburg, KS 66053
Phone/Fax: (913) 837-3214 Revision 1

Vermeer Manufacturing Company SN's: EUT1 / EUT2

Model: 510563863

FCC ID: 2AXF5-VTSHUB1

Test: 230206

IC: 26431-VTSHUB1

Test to: 47CFR 15C, RSS-Gen RSS-247 Date: April 10, 2023

File: TempSense Hub RFExp

Page 1 of 1

