Measurement Report
Kent
Test reports
Dongguan Yexun Electronic Technology Co,Ltd YXDZ-007 2BB48YXDZ-007 2BB48YXDZ007 yxdz 007
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 31 Pages, 2.90MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6704005FCC Test Report Report No: FCS202307132W02 Issued for Applicant: Dongguan Yexun Electronic Technology Co,Ltd Address: Room 201, Unit 1, Building 2, No.8 Hetangang Road, Humen Town, Dongguan, Guangdong, P.R.China Product Name: BATTERY POWERED BLUETOOTH SPEAKER Brand Name: DTEZTECH, Hiesuan, Hipoke, WaxPar, YEX-BUR, Taingwei, Giqtxpz, Zinkiwayr, GerttilyonAdisipsoarinpofgvtwny Byutrcfuy BeytvyowGrvodfrtamewryytuoJhjqzcyg HXHDLQYXXudzExag Model Name: YXDZ-007 Series Model: YXDZ-007-MT,YXDZ-007-DW,YXDZ-007-ML, YXDZ-007-BS,YXDZ-007-RYO, YXDZ-007-BD, YXDZ-007-CRA FCC ID: 2BB48YXDZ-007 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 2 of 31 Report No.:FCS202307132W02 TEST RESULT CERTIFICATION Applicant's Name...................... : Dongguan Yexun Electronic Technology Co,Ltd Address...................................... : Room 201, Unit 1, Building 2, No.8 Hetangang Road, Humen Town, Dongguan, Guangdong, P.R.China Manufacture's Name................ : Dongguan Yexun Electronic Technology Co,Ltd Address...................................... : Room 201, Unit 1, Building 2, No.8 Hetangang Road, Humen Town, Dongguan, Guangdong, P.R.China Product Description Product Name........................... : Brand Name .............................: Model Name.............................. : Series Model..............................: BATTERY POWERED BLUETOOTH SPEAKER DTEZTECH, Hiesuan, Hipoke, WaxPar, YEX-BUR, Taingwei, Giqtxpz, Zinkiwayr, GerttilyonAdisipsoarinpofgvtwnyByutrcfuy Beytvyow GYXrvDodZf-r0ta07mewryytuoJhjqzcygHXHDLQYXXudzExag YXDZ-007-MT,YXDZ-007-DW,YXDZ-007-ML,YXDZ-007-BS, YXDZ-007-RYO, YXDZ-007-BD, YXDZ-007-CRA Test Standards..........................: FCC Rules and Regulations Part 15 Subpart C, Section 249 Test Procedure..........................: ANSI C63.10:2013 This device described above has been tested FCS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of FCS, this document may be altered or revised by FCS, personal only, and shall be noted in the revision of the document.. Date of Test..................................: Date (s) of performance of tests. : July 15, 2023 ~ July 19, 2023 Date of Issue.................................: July 19 , 2023 Test Result.................................... : Pass Tested by : Reviewed by : Approved by : (Scott Shen) (Duke Qian) (Jack Wang) Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 3 of 31 Report No.:FCS202307132W02 Table of Contents Page 1. SUMMARY OF TEST RESULTS 5 1.1 TEST FACTORY 6 1.2 MEASUREMENT UNCERTAINTY 6 2. GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF THE EUT 7 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.4 EQUIPMENTS LIST 11 3 CONDUCTED EMISSION MEASUREMENT 12 3.1 LIMIT 12 3.2 TEST PROCEDURE 12 3.3 TEST SETUP 13 3.4 TEST RESULTS 14 4. RADIATED EMISSION MEASUREMENT 16 4.1 LIMIT 16 4.2 TEST PROCEDURE 17 4.3 TEST SETUP 18 4.4 TEST RESULTS 19 5. BAND EDGE TEST 24 5.1 LIMIT 25 5.2 TEST PROCEDURE 25 5.3 TEST SETUP 26 5.4 TEST RESULTS 27 6. 20 DB BANDWIDTH TEST 28 6.1 LIMIT 28 6.2 TEST PROCEDURE 28 6.3 TEST SETUP 28 6.4 TEST RESULTS 29 7. ANTENNA REQUIREMENT 31 7.1 STANDARD REQUIREMENT 31 7.2 EUT ANTENNA 31 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Rev. 00 Page 4 of 31 Report No.:FCS202307132W02 Revision History Issue Date July 19, 2023 Effect Page N/A Contents Initial Issue Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 5 of 31 Report No.:FCS202307132W02 1. SUMMARY OF TEST RESULTS Standard Section 15.207 15.205(a), 15.209(a), 15.249(a), 15.249(c) 15.209 15.249(d) 15.215(c) 15.203 FCC Part 15.249,Subpart C Test Item Conducted Emission Radiated Spurious Emission Field strength of fundamental Band Edge Emission 20dB Bandwidth Antenna Requirement Judgment PASS PASS PASS PASS PASS PASS Remark ------- NOTE: (1)" N/A" denotes test is not applicable in this Test Report (2) All tests are according to ANSI C63.10-2013 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 6 of 31 Report No.:FCS202307132W02 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 Laboray Accreditations FCC Test Firm Registration Number: 514908 CNAS Number L15566 Designation numberCN0127 A2LA accreditation number5545.01 ISED Number25801 CAB ID: CN0097 http://www.fcs-lab.com 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.71dB 2 Unwanted Emissions, conducted ±2.98 dB 3 Conducted Emission (9KHz-150KHz) ±4.13 dB 4 All emissions radiated (9KHz -30MHz) ±3.1 dB 5 Conducted Emission (150KHz-30MHz) ±4.74 dB 6 All emissions,radiated(<1G) 30MHz-1000MHz ±3.2 dB 7 All emissions,radiated (1GHz -18GHz) ±3.66 dB 8 All emissions,radiated (18GHz -40GHz) ±4.31 dB 9 Occupied bandwidth ±0.3 dB 10 PSD ±0.4 dB Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 7 of 31 Report No.:FCS202307132W02 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name Trade Name Model Name Series Model Model Difference Channel List BT Power Supply Battery BATTERY POWERED BLUETOOTH SPEAKER DTEZTECH, Hiesuan, Hipoke, WaxPar, YEX-BUR, Taingwei, Giqtxpz, Zinkiwayr, GerttilyonAdisipsoarinpofgvtwny Byutrcfuy BeytvyowGrvodfrtamewryytuoJhjqzcyg HXHDLQYXXudzExag YXDZ-007 YXDZ-007-MT,YXDZ-007-DW,YXDZ-007-ML, YXDZ-007-BS,YXDZ-007-RYO, YXDZ-007-BD, YXDZ-007-CRA We (Dongguan Yexun Electronic Technology Co,Ltd) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name and appearance color. Please refer to the Note 2. Frequency:2402-2480MHz Modulation: GFSK Data rate: 1Mbps Channel number: 40CH Type of antenna:Chip antenna PCB antenna Input:DC 20V by Battery output: DC5V2.1A(USB/TYPE-C) Li-ion 20V MAX 4.0Ah 80Wh Number of samples FCS202371328W02 Hardware version number M1828BPL-01A REV2.2 M1828BPL-01B REV2.0 Software version number exqtibmldsvwius7 1.0.2 Connecting I/O Port(s) Please refer to the User's Manual Note: 1. For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 8 of 31 Report No.:FCS202307132W02 2. Channel List Channel Freq.(MHz) 1 2402 2 2404 3 2406 4 2408 5 2410 6 2412 7 2414 8 2416 9 2418 10 2420 Channel 11 12 13 14 15 16 17 18 19 20 Freq.(MHz) 2422 2424 2426 2428 2430 2432 2434 2436 2438 2440 Channel 21 22 23 24 25 26 27 28 29 30 Freq.(MHz) 2442 2444 2446 2448 2450 2452 2454 2456 2458 2460 Channel 31 32 33 34 35 36 37 38 39 40 Freq.(MHz) 2462 2464 2466 2468 2470 2472 2474 2476 2478 2480 3. Table for Filed Antenna Ant. Brand 1 NA Model Name N/A Antenna Type Connector Gain (dBi) PCB Antenna N/A -0.68 NOTE Antenna Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 9 of 31 Report No.:FCS202307132W02 2.2 DESCRIPTION OF THE TEST MODES To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Test software: BT_Tool V1.0.9.exe The test softeware was used to control EUT work in continuous TX mode, and select test channel, Wireless mode as below table No. Test model descrption 1 Low channel GFSK 2 Middle channel GFSK 3 High channel GFSK Note: 1. All the test modes can be supply by battery, only the result of the worst case recorded in the report. GFSK mode is worst mode. 2. For radiated emission, 3 axis were chosen for testing for each applicable mode. 3. The EUT used fully charge battery when tested. 4. During the test, the dutycycle>98%, the test voltage was tuned from 85% to 115% of the Nominal rate supply votage, and found that the worst case was the nominal rated supply condition, So the report just shows that condition's data Configuration and peripherals Mode 1: DC EUT Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 10 of 31 Report No.:FCS202307132W02 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Necessary accessories Item Equipment 1 Adapter Mfr/Brand XIOAMI Model/Type No. MDY-11-EB Serial No. N/A Note this adapter is for testing only in repor Support units Item Equipment Mfr/Brand Model/Type No. Serial No. Note Manufacturer 2 Battery N/A BL1860 N/A N/A Dongguan Yexun Electronic Technology Co,Ltd Note: (1) The support equipment was authorized by Declaration of Confirmation. (2) For detachable type I/O cable should be specified the length in cm inLengthcolumn. (3) "YES" is means "shielded" "with core"; "NO" is means "unshielded" "without core". Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 11 of 31 Report No.:FCS202307132W02 2.4 EQUIPMENTS LIST Radiation Test equipment Kind of Equipment Manufacturer Type No. Company No. Last calibration Calibrated until EMI Test Receiver R&S ESRP 3 FCS-E001 2022. 08.30 2023. 08.29 Signal Analyzer R&S FSV40-N FCS-E012 2022. 08.30 2023. 08.29 Active loop Antenna ZHINAN ZN30900C FCS-E013 2022. 08.30 2023. 08.29 Bilog Antenna SCHWARZBECK VULB 9168 FCS-E002 2022. 08.30 2023. 08.29 Horn Antenna SCHWARZBECK BBHA 9120D SHF-EHF Horn Antenna (18G-40GHz) Pre-Amplifier(0.1M-3G Hz) Pre-Amplifier (1G-18GHz) Pre-Amplifier (18G-40GHz) Temperature & Humidity A-INFO EMCI N/A TERA-MW HTC-1 LB-180400-KF EM330N TSAMP-0518SE TRLA-0400 victor FCS-E003 FCS-E018 FCS-E004 FCS-E014 FCS-E019 FCS-E005 2022. 08.30 2022. 08.30 2022. 08.30 2022. 08.30 2022. 08.30 2022. 08.30 2023. 08.29 2023. 08.29 2023. 08.29 2023. 08.29 2023. 08.29 2023. 08.29 Conduction Test equipment Kind of Equipment Manufacturer Type No. Company No. Last calibration Calibrated until EMI Test Receiver R&S ESPI FCS-E020 2022. 08.30 2023. 08.29 LISN R&S ENV216 FCS-E007 2022. 08.30 2023. 08.29 LISN Temperature & Humidity ETS HTC-1 3810/2NM victor FCS-E009 FCS-E008 2022. 08.30 2022. 08.30 2023. 08.29 2023. 08.29 RF Connected Test Kind of Equipment Manufacturer Spectrum Analyzer Keysight Spectrum Analyzer Agilent Spectrum Analyzer R&S Type No. N9020A E4447A FSV-40 Company No. Last calibration Calibrated until FCS-E015 2022. 08.30 2023. 08.29 MY50180039 2022. 08.30 2023. 08.29 101499 2022. 08.30 2023. 08.29 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 12 of 31 Report No.:FCS202307132W02 3 CONDUCTED EMISSION MEASUREMENT 3.1 LIMIT Operating frequency band. In case the emission fall within the restricted band specified on Part 207(a) limit in the table below has to be followed. FREQUENCY (MHz) Conducted Emissionlimit (dBuV) Quasi-peak Average 0.15 -0.5 66 - 56 * 56 - 46 * 0.50 -5.0 56.00 46.00 5.0 -30.0 60.00 50.00 Note: (1) The tighter limit applies at the band edges. (2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 3.2 TEST PROCEDURE The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 kHz a. The EUT was 0.8 meters from the horizontal ground plane and 0.4 meters from the vertical ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item EUT Test Photos. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 13 of 31 Report No.:FCS202307132W02 3.3 TEST SETUP 40cm Vertical Reference Ground Plane EUT Test Receiver LISN 80cm Horizontal Reference Ground Plane Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80 cm from other units and other metal planes support. units. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 14 of 31 Report No.:FCS202307132W02 3.4 TEST RESULTS Temperature: Test Voltage: Test Mode: 22.1 DC 5V by adapter GFSK(worst) Relative Humidity: Phase: 56% L No. Frequency Reading Correct (MHz) (dBuV) Factor(dB/m) 1 0.1500 36.22 9.52 2 0.1500 17.51 9.52 3 0.5010 38.58 9.56 4 0.5010 35.90 9.56 5 1.5000 38.83 9.57 6 1.5000 26.34 9.57 7 3.4980 38.85 9.58 8 3.4980 33.67 9.58 9 6.5040 37.08 9.60 10 6.5040 31.63 9.60 11 15.4545 32.88 9.71 12 15.4545 24.52 9.71 Result (dBuV/m) 45.74 27.03 48.14 45.46 48.40 35.91 48.43 43.25 46.68 41.23 42.59 34.23 Limit (dBuV/m) 66.00 56.00 56.00 46.00 56.00 46.00 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 20.26 28.97 7.86 0.54 7.60 10.09 7.57 2.75 13.32 8.77 17.41 15.77 Remark QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 15 of 31 Report No.:FCS202307132W02 Temperature: Test Voltage: Test Mode: 22.1 DC 5V by adapter GFSK(worst) Relative Humidity: Phase: 56% N No. Frequency Reading Correct (MHz) (dBuV) Factor(dB/m) 1 0.1532 38.78 9.51 2 0.1532 19.85 9.51 3 0.4695 35.73 9.56 4 0.4695 30.82 9.56 5 1.4865 43.12 9.57 6 1.4865 35.73 9.57 7 2.4810 43.34 9.59 8 2.4810 35.61 9.59 9 5.4689 40.52 9.67 10 5.4689 34.06 9.67 11 14.4060 33.04 9.79 12 14.4060 26.52 9.79 Result (dBuV/m) 48.29 29.36 45.29 40.38 52.69 45.30 52.93 45.20 50.19 43.73 42.83 36.31 Limit (dBuV/m) 65.82 55.82 56.52 46.52 56.00 46.00 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 17.53 26.46 11.23 6.14 3.31 0.70 3.07 0.80 9.81 6.27 17.17 13.69 Remark QP AVG QP AVG QP AVG QP AVG QP AVG QP AVG Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 16 of 31 Report No.:FCS202307132W02 4. RADIATED EMISSION MEASUREMENT 4.1 LIMIT In any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the Restricted band specified on Part15.205(a)&209(a) limit in the table and according to ANSI C63.10-2013 below has to be followed LIMITS OF RADIATED EMISSION MEASUREMENT (0.009mhz - 1000mhz) Frequencies Field Strength Measurement Distance (MHz) (micorvolts/meter) (meters) 0.009~0.490 2400/F(KHz) 300 0.490~1.705 24000/F(KHz) 30 1.705~30.0 30 30 30~88 100 3 88~216 150 3 216~960 200 3 Above 960 500 3 LIMITS OF RADIATED EMISSION MEASUREMENT (1GHz-25 GHz) FREQUENCY (MHz) (dBuV/m) (at 3M) PEAK AVERAGE Above 1000 74 54 LIMITS OF FIELD STRENGTH OF THE FUNDAMENTAL SIGNAL FREQUENCY (MHz) (dBuV/m) (at 3M) PEAK AVERAGE 2400-2483.5 114 94 Notes: (1) The limit for radiated test was performed according to FCC PART 15C. (2) The tighter limit applies at the band edges. (3) Emission level (dBuV/m)=20log Emission level (uV/m). Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 17 of 31 Report No.:FCS202307132W02 4.2 TEST PROCEDURE Spectrum Parameter Setting Attenuation Auto Detector Peak/AV Start Frequency 1000 MHz(Peak/AV) Stop Frequency 10th carrier hamonic(Peak/AV) RB / VB (emission in restricted PK=1MHz / 1MHz, AV=1 MHz /10 Hz band) (Peak detector is for Both) a. The measuring distance of at 3 m shall be used for measurements at frequency 0.009MHz up to 1GHz,and above 1GHz. b. The EUT was placed on the top of a rotating table 0.8 meters (above 1GHz is 1.5 m) above the ground at a 3 meter anechoic chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation. c. The height of the equipment shall be 0.8 m(above 1GHz is 1.5 m); the height of the test antenna shall vary between 1 m to 4 m. horizontal and vertical polarizations of the antenna are set to make the measurement. d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then QuasiPeak detector mode re-measured. e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. f. For the actual test configuration, please refer to the related Item EUT Test Photos. Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported For fundamental frequency ,RBW>20dB BW ,VBW>RBW,PK detector for PK value, RMS detector for AV value. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 18 of 31 Report No.:FCS202307132W02 4.3 TEST SETUP ARadiated Emission Test-Up Frequency Below 30MHz BRadiated Emission Test-Up Frequency 30MHz~1GHz CRadiated Emission Test-Up Frequency Above 1GHz Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 19 of 31 Report No.:FCS202307132W02 4.4 TEST RESULTS Temperature: Test Mode: 25 GFSK (worst mode) For field strength of the fundamental signal Relative Humidity: 60% Test Voltage: DC 20V For spurious emission (9KHz-30MHz) Freq. (MHz) --- Reading (dBuV/m) --- Limit (dBuV/m) --- Margin (dB) --- State P/F --- Test Result PASS PASS Note: The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB); Limit line = specific limits (dBuv) + distance extrapolation factor. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 20 of 31 Report No.:FCS202307132W02 (30MHZ-1000MHZ) Temperature: Test Voltage: Test Mode: 23.7 DC 20V GFSK(worst mode) Relative Humidity: Phase: 61% Horizontal No. Frequency (MHz) 1 50.2324 2 157.0074 3 181.2834 4 255.6231 5 429.5228 6 711.6734 Reading (dBuV) 30.11 53.85 61.47 55.96 70.01 57.82 Correction (dB/m) -17.97 -32.24 -32.22 -32. 14 -31.97 -31.62 Result (dBuV/m) 12.14 21.61 29.25 23.82 38.04 26.20 Limit (dBuV/m) 40.00 43.50 43.50 46.00 46.00 46.00 Margin (dB) -27.86 -21.89 -14.25 -22.18 -7.96 -19.80 Remark QP QP QP QP QP QP Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 21 of 31 Report No.:FCS202307132W02 Temperature: Test Voltage: Test Mode: 22.7 DC 20V GFSK (worst mode) Relative Humidity: Phase: 61% Vertical No. Frequency (MHz) 1 42.1542 2 94.0979 3 178.7584 4 236.6447 5 411.8240 6 578.6699 Reading (dBuV) 34.92 54.76 59.67 56.44 67.67 61.46 Correction (dB/m) -14.74 -32.29 -32.22 -32. 16 -31.99 -31.80 Result (dBuV/m) 20.18 22.47 27.45 24.28 35.68 29.66 Limit (dBuV/m) 40.00 43.50 43.50 46.00 46.00 46.00 Margin (dB) -19.82 -21.03 -16.05 -21.72 -10.32 -16.34 Remarks: 1. Margin = Result (Result =Reading + Factor )Limit Remark QP QP QP QP QP QP Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 22 of 31 (1GHZ~25GHZ) LOW CH(GFSK)WORST MODE Report No.:FCS202307132W02 3.The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 23 of 31 MIDDLE CH(GFSK) WORST MODE Report No.:FCS202307132W02 3.3.THE AMPLITUDE OF SPURIOUS EMISSIONS WHICH ARE ATTENUATED BY MORE THAN 20DB BELOW THE PERMISSIBLE VALUE HAS NO NEED TO BE REPORTED. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 24 of 31 HIGH CH(GFSK)WORST MODE Report No.:FCS202307132W02 3.The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 25 of 31 Report No.:FCS202307132W02 5. BAND EDGE TEST 5.1 LIMIT According to §15.249(d), Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209, whichever is the lesser attenuation. 5.2 TEST PROCEDURE a. The EUT is placed on a turntable, which is 1.5m above ground plane. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out b. the highest emissions. Use the following spectrum analyzer settings: c. Span = wide enough to fully capture the emission being measured, RBW = 1 MHz, VBW RBW, Sweep = auto, Detector function = peak, Trace = max hold Follow the guidelines in ANSI C63.4 with respect to maximizing the emission by rotating the EUT, adjusting the measurement antenna height and polarization, etc. d. The peak reading of the emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak field strength, submit this data. Each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. Set the VBW to 10 Hz, while maintaining all of the other instrument settings. This peak level, once corrected, must comply with the limit specified in Section 15.209. If the duty cycle per channel of the hopping signal is less than 100 ms, then the reading obtained with e. the 10 Hz VBW may be further adjusted by a "duty cycle correction factor", derived from 20log(duty cycle/100 ms), in an effort to demonstrate compliance with the 15.209 limit. Submit this data. Note: For fundamental frequency ,RBW>20dB BW ,VBW>RBW,PK detector for PK value, RMS detector for AV value. Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 26 of 31 5.3 TEST SETUP Radiated Emission Test-Up Frequency Above 1GHz Report No.:FCS202307132W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 27 of 31 5.4 TEST RESULTS Low CH (GFSK)worst mode Report No.:FCS202307132W02 High CH(GFSK) worst mode Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 28 of 31 Report No.:FCS202307132W02 6. 20 DB BANDWIDTH TEST 6.1 LIMIT According to 15.215 (c) Intentional radiators operating under the alternative provisions to the general emission limits, as contained in § 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated. The requirement to contain the designated bandwidth of the emission within the specified frequency band includes the effects from frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a frequency stability is not specified in the regulations, it is recommended that the fundamental emission be kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of-band operation 6.2 TEST PROCEDURE Check the calibration of the measuring instrument using either an internal calibrator or a a. known signal from an external generator b. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient frequency within its operating range. Set a reference level on the measuring instrument equal to the highest peak value. c. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference level. Record the frequency difference as the emission bandwidth. 6.3 TEST SETUP Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 29 of 31 Report No.:FCS202307132W02 6.4 TEST RESULTS Temperature: Test Mode: 25 GFSK Frequency 2402 MHz 2440 MHz 2480 MHz Relative Humidity: 50% Test Voltage: DC 20V 20dB Bandwidth (MHz) 1.116 1.132 1.140 Result PASS PASS PASS 2402 MHz Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 30 of 31 Report No.:FCS202307132W02 2440 MHz 2480 MHz Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com Page 31 of 31 Report No.:FCS202307132W02 7. ANTENNA REQUIREMENT 7.1 STANDARD REQUIREMENT 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. 7.2 EUT ANTENNA The antennas used for this product are PCB antenna and other than that furnished by the responsible party shall be used with the device, the maximum peak gain of the transmit antenna is -0.68dBi. END OF THE REPORT Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com
Related FCC IDs:
- 2BB48YXDZ-007 - Dongguan Yexun Electronic Technology Co,Ltd BATTERY POWERED BLUETOOTH SPEAKER [YXDZ-007] WPS 文字 macOS 版本12.6.1(版号21G217) Quartz PDFContext