SZ24080104S01 JIUZHOU DTW5511CL FCC RF Exposure
SZ24080104S01 RF Exposure
Shenzhen Jiuzhou Electric Co., Ltd. DTW5511CL00002 2AL9QDTW5511CL00002 2AL9QDTW5511CL00002 dtw5511cl00002
Shenzhen Jiuzhou Electric Co., Ltd. DTW5511CL00002 Router 2AL9QDTW5511CL00002 2AL9QDTW5511CL00002 dtw5511cl00002
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 8 Pages, 396.61KB
Document DEVICE REPORTGetApplicationAttachment.html?id=7853094REPORT No.SZ24080104S01 RF EXPOSURE EVALUATION REPORT APPLICANT : SHENZHEN JIUZHOU ELECTRIC CO.,LTD. PRODUCT NAME : Router MODEL NAME : DTW5511CL BRAND NAME : Claro FCC ID : 2AL9QDTW5511CL00002 STANDARD(S) : 47 CFR Part 2(2.1091) RECEIPT DATE : 2024-08-13 TEST DATE : 2024-09-09 to 2024-10-23 ISSUE DATE : 2024-11-12 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued byShenzhenMorlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 1 of 8 REPORT No.SZ24080104S01 DIRECTORY 1. Technical Information 3 1.1 Applicant and Manufacturer Information 3 1.2 Equipment under Test (EUT) Description 3 1.3 Applied Reference Documents 4 2. Device Category and RF Exposure Limit 5 3. Maximum Average Power Summary 6 4. RF Exposure Assessment 7 Annex A Testing Laboratory Information 8 Version 1.0 Change History Date 2024-11-12 Reason for change First edition MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 2 of 8 1. Technical Information REPORT No.SZ24080104S01 Note: Provide by applicant. 1.1 Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: SHENZHEN JIUZHOU ELECTRIC CO.,LTD. 6F,Jiuzhou Electric Building, Southern No. 12 Rd., High-tech Industrial Park, Nanshan District, Shenzhen,China SHENZHEN JIUZHOU ELECTRIC CO.,LTD. 6F,Jiuzhou Electric Building, Southern No. 12 Rd., High-tech Industrial Park, Nanshan District, Shenzhen,China 1.2 Equipment under Test (EUT) Description Product Name: Router Sample No.: 3#, 5# Hardware Version: V2.0 Software Version: V3.1.0.6 Frequency Bands: Modulation Mode: WLAN 2.4GHz WLAN 5GHz WLAN 2.4GHz WLAN 5GHz 2412MHz-2472MHz 5180MHz-5240MHz; 5260MHz-5320MHz; 5500MHz-5720MHz; 5745MHz-5825MHz DSSS, OFDM, OFDMA OFDM, OFDMA WLAN 2.4GHz Antenna Type: PCB Antenna Antenna Gain: ANT1: 2.80dBi; ANT2: 3.74dBi Antenna Information: WLAN 5GHz Antenna Type: PCB Antenna Antenna Gain: ANT1: 6.47dBi; ANT2: 6.47dBi Note 1: The EUT has two antennas and it operates in single antenna. Both of the two antennas were evaluated separately, only the worst test result were recorded in the test report. MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 3 of 8 1.3 Applied Reference Documents REPORT No.SZ24080104S01 Leading reference documents for testing: Method Identity Document Title Determination /Remark 47 CFR Part 2(2.1091) Radio Frequency Radiation Exposure Assessment: mobile devices No deviation KDB 447498 D01v06 General RF Exposure Guidance No deviation Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 2: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 4 of 8 REPORT No.SZ24080104S01 2. Device Category and RF Exposure Limit Per user manual, based on 47 CFR 2.1091, this device belongs to mobile device category with General Population/Uncontrolled exposure. Mobile Devices: 47 CFR 2.1091(b) For purposes of this section, a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term "fixed location" means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 centimeter separation requirement. General Population/Uncontrolled Exposure: The general population/uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general public would come under this category when exposure is not employment-related; for example, in the case of a wireless transmitter that exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are not considered sufficient to allow the device to be considered under the occupational/controlled category, and the general population/uncontrolled exposure limits apply to these devices. Table 1Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm2) Averaging time (minutes) (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 30 1.34-30 824/f 2.19/f *(180/f2) 30 30-300 27.5 0.073 0.2 30 300-1500 - - f/1500 30 1500-100,000 - - 1.0 30 f = frequency in MHz* = Plane-wave equivalent power density MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 5 of 8 REPORT No.SZ24080104S01 3. Maximum Average Power Summary Wireless Mode Channel Frequency (MHz) Max. Average Power (dBm) Tune-up Limit (dBm) WLAN 2.4GHz CH 1 2412 23.38 23.50 WLAN 5GHz CH 36 5180 23.74 24.00 Note 1: According to KDB 447498, MPE assessment is based on source-based time-averaged maximum conducted output power of the RF channel requiring assessment, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. Note 2: The maximum average power refers to report (Report No.: SZ24080104W01/W02). MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 6 of 8 REPORT No.SZ24080104S01 4. RF Exposure Assessment Standalone Transmission Assessment <Standalone Antenna Transmission Assessment> Bands Frequency Tune-up (MHz) Power(dBm) Antenna Gain(dBi) E.I.R.P. (mW) Power Limit for Density MPE (mW/cm²) (mW/cm²) WLAN 2.4GHz 2412 23.50 2.80 426.58 0.085 1.0 WLAN 5GHz 5180 24.50 6.47 1250.26 0.249 1.0 Note: 1. According to KDB 447498, MPE assessment is based on source-based time-averaged maximum conducted output power of the RF channel requiring assessment, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. 2. MPE calculate method S = PG/4R² Where: S= Power density (in appropriate units, e.g. mW/cm²) P = Time-average maximum tune-up power (in appropriate units, e.g. dBm) G = numeric gain of the antenna (in appropriate units, e.g. dBi) R = Separation distance to the centre of radiation of the antenna (20cm) Simultaneous Transmission Assessment: According to the user manual, the WLAN transmitters in the device cannot operate simultaneously, therefore simultaneous transmission analysis is not required. Conclusion: According to 47 CFR §2.1091, this device complies with human exposure basic restrictions. MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 7 of 8 REPORT No.SZ24080104S01 Annex A Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 Laboratory Address: LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China Telephone: +86 755 36698555 Facsimile: +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. END OF REPORT MORLAB ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 8 of 8
Related FCC IDs:
- 2AL9QDTW5511CL00002 - Shenzhen Jiuzhou Electric Co., Ltd. Router [DTW5511CL00002] Morlab Acrobat Distiller 9.3.2 (Windows)