SZ24080104S01 JIUZHOU DTW5511CL FCC RF Exposure

SZ24080104S01 RF Exposure

Shenzhen Jiuzhou Electric Co., Ltd. DTW5511CL00002 2AL9QDTW5511CL00002 2AL9QDTW5511CL00002 dtw5511cl00002

Shenzhen Jiuzhou Electric Co., Ltd. DTW5511CL00002 Router 2AL9QDTW5511CL00002 2AL9QDTW5511CL00002 dtw5511cl00002

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 8 Pages, 396.61KB

Document DEVICE REPORTGetApplicationAttachment.html?id=7853094
REPORT No.SZ24080104S01
RF EXPOSURE EVALUATION REPORT

APPLICANT

: SHENZHEN JIUZHOU ELECTRIC CO.,LTD.

PRODUCT NAME : Router

MODEL NAME

: DTW5511CL

BRAND NAME

: Claro

FCC ID

: 2AL9QDTW5511CL00002

STANDARD(S)

: 47 CFR Part 2(2.1091)

RECEIPT DATE : 2024-08-13

TEST DATE

: 2024-09-09 to 2024-10-23

ISSUE DATE

: 2024-11-12

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued byShenzhenMorlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]

Page 1 of 8

REPORT No.SZ24080104S01
DIRECTORY
1. Technical Information 3 1.1 Applicant and Manufacturer Information 3 1.2 Equipment under Test (EUT) Description 3 1.3 Applied Reference Documents  4 2. Device Category and RF Exposure Limit  5 3. Maximum Average Power Summary  6 4. RF Exposure Assessment  7 Annex A Testing Laboratory Information  8

Version 1.0

Change History Date 2024-11-12

Reason for change First edition

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 2 of 8

1. Technical Information

REPORT No.SZ24080104S01

Note: Provide by applicant.
1.1 Applicant and Manufacturer Information

Applicant: Applicant Address: Manufacturer: Manufacturer Address:

SHENZHEN JIUZHOU ELECTRIC CO.,LTD. 6F,Jiuzhou Electric Building, Southern No. 12 Rd., High-tech Industrial Park, Nanshan District, Shenzhen,China SHENZHEN JIUZHOU ELECTRIC CO.,LTD. 6F,Jiuzhou Electric Building, Southern No. 12 Rd., High-tech Industrial Park, Nanshan District, Shenzhen,China

1.2 Equipment under Test (EUT) Description

Product Name:

Router

Sample No.:

3#, 5#

Hardware Version:

V2.0

Software Version:

V3.1.0.6

Frequency Bands: Modulation Mode:

WLAN 2.4GHz
WLAN 5GHz WLAN 2.4GHz WLAN 5GHz

2412MHz-2472MHz 5180MHz-5240MHz; 5260MHz-5320MHz; 5500MHz-5720MHz; 5745MHz-5825MHz DSSS, OFDM, OFDMA OFDM, OFDMA

WLAN 2.4GHz Antenna Type: PCB Antenna

Antenna Gain: ANT1: 2.80dBi; ANT2: 3.74dBi Antenna Information:
WLAN 5GHz

Antenna Type: PCB Antenna

Antenna Gain: ANT1: 6.47dBi; ANT2: 6.47dBi

Note 1: The EUT has two antennas and it operates in single antenna. Both of the two antennas were evaluated separately, only the worst test result were recorded in the test report.

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 3 of 8

1.3 Applied Reference Documents

REPORT No.SZ24080104S01

Leading reference documents for testing:

Method

Identity

Document Title

Determination

/Remark

47 CFR Part 2(2.1091)

Radio Frequency Radiation Exposure Assessment: mobile devices

No deviation

KDB 447498 D01v06

General RF Exposure Guidance

No deviation

Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in

the "Remark" of the above table.

Note 2: When the test result is a critical value, we will use the measurement uncertainty give

the judgment result based on the 95% confidence intervals.

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 4 of 8

REPORT No.SZ24080104S01
2. Device Category and RF Exposure Limit

Per user manual, based on 47 CFR 2.1091, this device belongs to mobile device category with

General Population/Uncontrolled exposure.

Mobile Devices:

47 CFR 2.1091(b)

For purposes of this section, a mobile device is defined as a transmitting device designed to be

used in other than fixed locations and to generally be used in such a way that a separation distance

of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s)

and the body of the user or nearby persons. In this context, the term "fixed location" means that the

device is physically secured at one location and is not able to be easily moved to another location.

Transmitting devices designed to be used by consumers or workers that can be easily re-located,

such as wireless devices associated with a personal computer, are considered to be mobile

devices if they meet the 20 centimeter separation requirement.

General Population/Uncontrolled Exposure:

The general population/uncontrolled exposure limits are applicable to situations in which the

general public may be exposed or in which persons who are exposed as a consequence of their

employment may not be made fully aware of the potential for exposure or cannot exercise control

over their exposure. Members of the general public would come under this category when

exposure is not employment-related; for example, in the case of a wireless transmitter that

exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as

cellular telephones are not considered sufficient to allow the device to be considered under the

occupational/controlled category, and the general population/uncontrolled exposure limits apply to

these devices.

Table 1Limits for Maximum Permissible Exposure (MPE)

Frequency range (MHz)

Electric field strength (V/m)

Magnetic field strength (A/m)

Power density (mW/cm2)

Averaging time
(minutes)

(B) Limits for General Population/Uncontrolled Exposure

0.3-1.34

614

1.63

*(100)

30

1.34-30

824/f

2.19/f

*(180/f2)

30

30-300

27.5

0.073

0.2

30

300-1500

-

-

f/1500

30

1500-100,000

-

-

1.0

30

f = frequency in MHz* = Plane-wave equivalent power density

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 5 of 8

REPORT No.SZ24080104S01
3. Maximum Average Power Summary

Wireless Mode

Channel

Frequency (MHz)

Max. Average Power (dBm)

Tune-up Limit (dBm)

WLAN 2.4GHz

CH 1

2412

23.38

23.50

WLAN 5GHz

CH 36

5180

23.74

24.00

Note 1: According to KDB 447498, MPE assessment is based on source-based time-averaged maximum conducted output power of the RF channel requiring assessment, adjusted for tune-up

tolerance, and the minimum test separation distance required for the exposure conditions.

Note 2: The maximum average power refers to report (Report No.: SZ24080104W01/W02).

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 6 of 8

REPORT No.SZ24080104S01

4. RF Exposure Assessment

 Standalone Transmission Assessment

<Standalone Antenna Transmission Assessment>

Bands

Frequency Tune-up (MHz) Power(dBm)

Antenna Gain(dBi)

E.I.R.P. (mW)

Power Limit for

Density

MPE

(mW/cm²) (mW/cm²)

WLAN 2.4GHz

2412

23.50

2.80

426.58 0.085

1.0

WLAN 5GHz

5180

24.50

6.47 1250.26 0.249

1.0

Note:

1. According to KDB 447498, MPE assessment is based on source-based time-averaged

maximum conducted output power of the RF channel requiring assessment, adjusted for

tune-up tolerance, and the minimum test separation distance required for the exposure

conditions.

2. MPE calculate method

S = PG/4R²

Where: S= Power density (in appropriate units, e.g. mW/cm²) P = Time-average maximum tune-up power (in appropriate units, e.g. dBm) G = numeric gain of the antenna (in appropriate units, e.g. dBi) R = Separation distance to the centre of radiation of the antenna (20cm)

 Simultaneous Transmission Assessment: According to the user manual, the WLAN transmitters in the device cannot operate simultaneously, therefore simultaneous transmission analysis is not required.

 Conclusion: According to 47 CFR §2.1091, this device complies with human exposure basic restrictions.

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 7 of 8

REPORT No.SZ24080104S01
Annex A Testing Laboratory Information

1. Identification of the Responsible Testing Laboratory

Laboratory Name:

Shenzhen Morlab Communications Technology Co., Ltd.

FL.1-3, Building A, FeiYang Science Park, No.8

Laboratory Address:

LongChang Road, Block 67, BaoAn District, ShenZhen,

GuangDong Province, P. R. China

Telephone:

+86 755 36698555

Facsimile:

+86 755 36698525

2. Identification of the Responsible Testing Location

Name: Address:

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174.

END OF REPORT

MORLAB

ShenzhenMorlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 8 of 8

