Harman International Industries, Inc.

BLUETOOTH HEADSET

VIBE, FLEX

Test report for BLE

Harman International Industries, Inc JBLVFLEX BLUETOOTH HEADSET APIJBLVFLEX APIJBLVFLEX jblvflex

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 97 Pages, 4.26MB

Document DEVICE REPORTGetApplicationAttachment.html?id=5960710
Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02
Report No.:DDT-R22050910-2E02 Issued Date: Jun. 02, 2022

FCC AND ISED CERTIFICATION TEST REPORT

FOR

Applicant Address Equipment under Test

: Harman International Industries, Inc.

:

8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES

: BLUETOOTH HEADSET

Model No.

: VIBE FLEX

Trade Mark

: JBL

FCC ID

: APIJBLVFLEX

IC

: 6132A-JBLVFLEX

Manufacturer Address

: Harman International Industries, Inc.

:

8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES

Issued By: Dongguan Dongdian Testing Service Co., Ltd.

Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808
Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com

Page 1 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Table of Contents

Test report declares.......................................................................................................4

1.

Summary of Test Results............................................................................................... 6

2.

General Test Information ............................................................................................... 7

2.1.

Description of EUT ......................................................................................................... 7

2.2.

Accessories of EUT........................................................................................................ 7

2.3.

Assistant equipment used for test .................................................................................. 8

2.4.

Block diagram of EUT configuration for test .................................................................. 8

2.5.

Test environment conditions .......................................................................................... 8

2.6.

Deviations of test standard............................................................................................. 8

2.7.

Test laboratory ............................................................................................................... 9

2.8.

Measurement uncertainty............................................................................................... 9

3.

Equipment Used During Test ....................................................................................... 10

4.

6 dB Bandwidth and 99% Bandwidth........................................................................... 11

4.1.

Block diagram of test setup.......................................................................................... 11

4.2.

Limits ............................................................................................................................ 11

4.3.

Test procedure ............................................................................................................. 11

4.4.

Test result..................................................................................................................... 12

4.5.

Original test data .......................................................................................................... 13

5.

Maximum Peak Output Power ..................................................................................... 21

5.1.

Block diagram of test setup.......................................................................................... 21

5.2.

Limits ............................................................................................................................ 21

5.3.

Test procedure ............................................................................................................. 21

5.4.

Test result..................................................................................................................... 22

5.5.

Original test data .......................................................................................................... 23

6.

Power Spectral Density ................................................................................................ 27

6.1.

Block diagram of test setup.......................................................................................... 27

6.2.

Limits ............................................................................................................................ 27

6.3.

Test procedure ............................................................................................................. 27

6.4.

Test result..................................................................................................................... 28

6.5.

Original test data .......................................................................................................... 29

7.

Band Edge Compliance (Conducted Method) ............................................................. 33

7.1.

Block diagram of test setup.......................................................................................... 33

7.2.

Limits ............................................................................................................................ 33

7.3.

Test procedure ............................................................................................................. 33

7.4.

Test result..................................................................................................................... 33

7.5.

Original test data .......................................................................................................... 34

8.

Radiated Emission ....................................................................................................... 37

Page 2 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

8.1. 8.2. 8.3. 8.4. 9. 9.1. 9.2. 9.3. 9.4. 9.5. 10. 10.1. 10.2. 10.3. 10.4. 11. 11.1. 11.2. 11.3. 11.4. 12. 12.1. 12.2.

Block diagram of test setup.......................................................................................... 37 Limit .............................................................................................................................. 38 Test Procedure............................................................................................................. 40 Test result..................................................................................................................... 41 RF Conducted Spurious Emissions ............................................................................. 70 Block diagram of test setup.......................................................................................... 70 Limits ............................................................................................................................ 70 Test procedure ............................................................................................................. 70 Test result..................................................................................................................... 71 Original test data .......................................................................................................... 72 Emissions in Restricted Frequency Bands .................................................................. 84 Block diagram of test setup.......................................................................................... 84 Limit .............................................................................................................................. 84 Test procedure ............................................................................................................. 84 Test result..................................................................................................................... 84 Power Line Conducted Emission ................................................................................. 93 Block diagram of test setup.......................................................................................... 93 Power line conducted emission limits .......................................................................... 93 Test procedure ............................................................................................................. 93 Test result..................................................................................................................... 94 Antenna Requirements ................................................................................................ 97 Limit .............................................................................................................................. 97 Result ........................................................................................................................... 97

Page 3 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Test Report Declare

Applicant Address Equipment under Test Model No. Trade Mark Manufacturer Address

: Harman International Industries, Inc.

:

8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES

: BLUETOOTH HEADSET

: VIBE FLEX

: JBL

: Harman International Industries, Inc.

:

8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES

Test Standard Used: FCC Rules and Regulations Part 15 Subpart C, RSS-247 Issue 2 February 2017.
Test Procedure Used:
ANSI C63.10:2013, RSS-Gen Issue 5, Apr. 2018, Amendment 2 (February 2021) We Declare: The equipment described above is tested by Dongguan Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Dongguan Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests.
After test and evaluation, our opinion is that the equipment provided for test compliance with the requirement of the above FCC&ISED standards.

Report No.:

DDT-R22030409-2E02

Date of Receipt: May 10, 2022

Date of Test: May 10, 2022 ~ May 31, 2022

Prepared By:

ApproveGDdIANBTyES:TING S

DONGGUAN DON

ERVICE CO., LTD

.

____________________ Bobo Chen/Engineer

______________________ Damon Hu/EMC Manager

Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Dongguan Dongdian Testing Service Co., Ltd.

Page 4 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Rev. Revisions --- Initial issue

Revision History

Issue Date

Revised By

Jun. 02, 2022

Page 5 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

1. Summary of Test Results

The EUT have been tested according to the applicable standards as referenced below.

Description of Test Item

Standard

Verdict

6 dB Bandwidth and 99% Bandwidth Peak Output Power
Power Spectral Density Band Edge Compliance
(conducted method) Radiation Emission
RF Conducted Spurious Emissions
Emission in Restricted Frequency Bands Power Line Conducted Emission Antenna Requirement

FCC Part 15: 15.247 ANSI C63.10:2013
RSS-247 Issue 2 FCC Part 15: 15.247 ANSI C63.10:2013
RSS-247 Issue 2 FCC Part 15:15.247 ANSI C63.10:2013
RSS-247 Issue 2 FCC Part 15: 15.209 FCC Part 15: 15.247 ANSI C63.10: 2013
RSS-247 Issue 2 RSS-Gen Issue 5 FCC Part 15: 15.247 ANSI C63.10:2013 RSS-247 Issue 2 RSS-Gen Issue 5 FCC Part 15: 15.209 FCC Part 15: 15.247 ANSI C63.10: 2013 RSS-247 Issue 2 RSS-Gen Issue 5 FCC Part 15: 15.209 FCC Part 15: 15.247 ANSI C63.10: 2013 RSS-247 Issue 2 RSS-Gen Issue 5 FCC Part 15: 15.207 ANSI C63.10: 2013 RSS-Gen Issue 5 FCC Part 15: 15.203 RSS-Gen Issue 5

Pass Pass Pass Pass Pass Pass
Pass Pass Pass

Page 6 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

2. General Test Information

2.1. Description of EUT

EUT* Name

: BLUETOOTH HEADSET

Model Number

: VIBE FLEX

EUT Function Description Power Supply Radio Specification

: Please reference user manual of this device

CHARGING CASE: DC 5V from USB

:

EARBUDS: DC 5V from external charging case CHARGING CASE: DC 3.85V Polymer Li-ion built-in

battery

EARBUDS: DC 3.85V Polymer Li-ion built-in battery

: Bluetooth V5.2

Operation Frequency

: 2402 MHz - 2480 MHz

Modulation

: GFSK

Data Rate

: 1 Mbps

Antenna Gain

:

Left side: -0.59 dBi Right side: -0.34 dBi

Sample Type

: Series production

Sample Number

:

S22030409-17 S22030409-18

for for

conductive radiation

Note: EUT is the ab. of equipment under test.

Channel information

Channel

Frequency (MHz)

0

2402

1

2404

2

2406

3

2408

4

2410

5

2412

6

2414

7

2416

8

2418

9

2420

10

2422

11

2424

12

2426

13

2428

Channel
14 15 16 17 18 19 20 21 22 23 24 25 26 27

Frequency (MHz) 2430 2432 2434 2436 2438 2440 2442 2444 2446 2448 2450 2452 2454 2456

Channel
28 29 30 31 32 33 34 35 36 37 38 39

Frequency (MHz) 2458 2460 2462 2464 2466 2468 2470 2472 2474 2476 2478 2480

2.2. Accessories of EUT

Description of Accessories
Type-C Cable

Manufacturer Harman

Model number N/A

Description Length: 0.2m

Remark N/A

Page 7 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

2.3. Assistant equipment used for test

Assistant equipment
Adapter

Manufacturer

Model number

EMC Compliance

SN

HUAWEI

Input: 100-240~, 50/60Hz,

HW-100400C01 1.2A; Output: 5V/2A or

N/A

9V/2A or 10V/ 4A

2.4. Block diagram of EUT configuration for test

AC Mains

AC Adapter

EUT

Test software: wvt_gui.exe

The test software was used to control EUT work in Continuous Tx mode, and select test channel,

wireless mode as below table:

Tested mode, channel, information

Mode

Setting Tx Power

Channel

Frequency (MHz)

1

CH0

2402

GFSK 1M

1

CH19

2440

1

CH39

2480

1

CH0

2402

GFSK 2M

1

CH19

2440

1

CH39

2480

2.5. Test environment conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature range: Humidity range: Pressure range:

21-25  40-75% 86-106 kPa

2.6. Deviations of test standard
No deviation.

Page 8 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

2.7. Test laboratory
Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, G-20118

2.8. Measurement uncertainty

Test Item

Uncertainty

Bandwidth

1.1%

Peak Output Power (Conducted) (Spectrum analyzer)

0.86 dB (10 MHz  f < 3.6 GHz); 1.38 dB (3.6 GHz  f < 8 GHz)

Peak Output Power (Conducted) (Power Sensor)

0.74 dB

Power Spectral Density

0.74 dB (10 MHz  f < 3.6 GHz); 1.38 dB (3.6 GHz  f < 8 GHz)

Frequencies Stability

6.7 x 10-8 (Antenna couple method) 5.5 x 10-8 (Conducted method)

0.86 dB (10 MHz  f < 3.6 GHz);

Conducted spurious emissions

1.40 dB (3.6 GHz  f < 8 GHz)

1.66 dB (8 GHz  f < 22 GHz)

Uncertainty for radio frequency (RBW < 20 kHz)

3×10-8

Temperature

0.4 

Humidity

2 %

Uncertainty for Radiation Emission test (30 MHz - 1 GHz)

4.70 dB (Antenna Polarize: V) 4.84 dB (Antenna Polarize: H)

4.10 dB (1 - 6 GHz)

Uncertainty for Radiation Emission test (1 GHz - 40 GHz)

4.40 dB (6 GHz - 18 GHz) 3.54 dB (18 GHz - 26 GHz)

4.30 dB (26 GHz - 40 GHz)

Uncertainty for Power line conduction emission test

3.72 dB (9 kHz-150 kHz) 3.32 dB (150 kHz - 30 MHz)

Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Page 9 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

3. Equipment Used During Test

Equipment

Manufacturer Model No. Serial No.

RF Connected Test (Tonscend RF Measurement System 4#)

Last Cal.

Cal. Interval

MXA Signal Analyzer Agilent

N9020A

MY49100362 Sep. 02, 2021 1 Year

Signal &Spectrum analyzer Wideband Radio Communication tester MXG Vector Signal Generator Vector Signal Generator

R&S R&S Agilent Agilent

FSV3044 CMW500 N5182B E8267D

101173 120259 MY59100192 US49060192

Apr. 13, 2022 1 Year May 18, 2022 1 Year May 18, 2022 1 Year Oct. 15, 2021 1 Year

RF Control Unit

Tonsend

JS0806-2 21I8060485

Oct. 18, 2021 1 Year

Temp&Humi Programmable

ZHIXIANG

ZXGDJS-150 L

ZX170110-A

May 16, 2022 1 Year

Test Software

JS Tonscend JS1120-3 Ver.2.6.88.0346 N/A

N/A

Radiation 3#chamber

EMI Test Receiver

R&S

ESU

100472

Jun. 01, 2021 1 Year

Spectrum analyzer Agilent

E4447A

MY50180031 Jun. 01, 2021 1 Year

Active Loop antenna Schwarzbeck FMZB-1519 1519-038

Sep. 19, 2021 1 Year

Trilog Broadband Antenna Double Ridged Horn Antenna Broad Band Horn Antenna
Pre-amplifier
Pre-amplifier

Schwarzbeck VULB 9163 01429

Schwarzbeck BBHA9120 02468

Schwarzbeck BBHA 9170 790

COM-POWE R COM-POWE R

PAM-118A PAM-840A

18040084 461369

Aug. 07, 2021 1 Year Nov. 17, 2021 1 Year May 06, 2022 1 Year Sep. 02, 2021 1 Year Apr. 11, 2022 1 Year

Test software

Audix

E3

V 6.1.1.1

N/A

N/A

Power Line Conducted Emissions Test 2#

Test Receiver

R&S

ESCI

101028

Sep. 02, 2021 1 Year

LISN 1

R&S

ENV216 101170

Sep. 07, 2021 1 Year

LISN 2

R&S

ENV216 101209

Sep. 02, 2021 1 Year

Pulse Limiter

R&S

KH43101

431011801568-1 2#

May 17, 2022

1 Year

CE Cable 2

HUBSER RG214-5 N/A

May 17, 2022 1 Year

Test software

Audix

E3

V 6.11111b

N/A

N/A

Page 10 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

4. 6 dB Bandwidth and 99% Bandwidth
4.1. Block diagram of test setup

4.2. Limits
For direct sequence systems, the minimum 6 dB bandwidth shall be at least 500 kHz

4.3. Test procedure

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) 99% Bandwidth set the spectrum analyzer as follows:

RBW:

1% to 5% of the OBW

VBW:

approximately three times RBW

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) 6 dB Bandwidth set the spectrum analyzer as follows:

RBW:

100 kHz

VBW:

300 kHz

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(4) Allow the trace to stabilize, measure the 6 dB and 99% bandwidth of signal.

Page 11 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

4.4. Test result
Left side:

Mode Channel

GFSK 1M GFSK 1M

CH0 CH19 CH39 CH0 CH19 CH39

99% bandwidth Result (MHz)
1.016 1.016 1.016 2.032 2.032 2.028

Right side:

Mode Channel

GFSK 1M GFSK 1M

CH0 CH19 CH39 CH0 CH19 CH39

99% bandwidth Result (MHz)
1.016 1.020 1.012 2.036 2.036 2.032

6 dB bandwidth Result (MHz) 0.700 0.704 0.684 1.184 1.184 1.184

6 dB width Limit (MHz) >0.5 >0.5 >0.5 >0.5 >0.5 >0.5

6 dB bandwidth Result (MHz) 0.700 0.692 0.700 1.184 1.184 1.180

6 dB width Limit (MHz) >0.5 >0.5 >0.5 >0.5 >0.5 >0.5

Verdict Pass Pass Pass Pass Pass Pass
Verdict Pass Pass Pass Pass Pass Pass

Page 12 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

4.5. Original test data

99% bandwidth Left side:

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2402

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1 T1
T2

Marker 1 [T1 ] 3.33 dBm
2.401968000 GHz
OBW 1.016000000 MHz Temp 1 [T1 OBW]
-10.48 dBm A 2.401504000 GHz Temp 2 [T1 OBW]
-11.74 dBm LVL
2.402520000 GHz

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:24:14

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2440

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1 T1
T2

Marker 1 [T1 ] 3.86 dBm
2.439964000 GHz
OBW 1.016000000 MHz Temp 1 [T1 OBW]
-9.70 dBm A 2.439504000 GHz Temp 2 [T1 OBW]
-11.00 dBm LVL
2.440520000 GHz

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:27:06

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2480

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1 T1
T2

Marker 1 [T1 ] 3.38 dBm
2.479968000 GHz
OBW 1.016000000 MHz Temp 1 [T1 OBW]
-10.37 dBm A 2.479504000 GHz Temp 2 [T1 OBW]
-11.73 dBm LVL
2.480520000 GHz

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:28:46

Page 13 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2402

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

Marker 1 [T1 ] 1.05 dBm
2.401960000 GHz
OBW 2.032000000 MHz Temp 1 [T1 OBW]
-13.50 dBm A 2.401004000 GHz Temp 2 [T1 OBW]
-13.33 dBm LVL
2.403036000 GHz

-10

T1

T2

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:32:29

BLE 2M_Ant1_2440

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

Marker 1 [T1 ] 1.67 dBm
2.439964000 GHz
OBW 2.032000000 MHz Temp 1 [T1 OBW]
-12.68 dBm A 2.439004000 GHz Temp 2 [T1 OBW]
-12.89 dBm LVL
2.441036000 GHz

-10

T1

T2

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:34:42

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2480

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

Marker 1 [T1 ] 1.26 dBm
2.479960000 GHz
OBW 2.028000000 MHz Temp 1 [T1 OBW]
-13.22 dBm A 2.479004000 GHz Temp 2 [T1 OBW]
-13.33 dBm LVL
2.481032000 GHz

-10

T1

T2

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:36:31

Page 14 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Right side:

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2402

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

T1

T2

Marker 1 [T1 ] 2.66 dBm
2.401972000 GHz
OBW 1.016000000 MHz Temp 1 [T1 OBW]
-11.50 dBm A 2.401508000 GHz Temp 2 [T1 OBW]
-12.32 dBm LVL
2.402524000 GHz

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:49:34

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2440

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

T1

T2

Marker 1 [T1 ] 3.25 dBm
2.439972000 GHz
OBW 1.020000000 MHz Temp 1 [T1 OBW]
-10.84 dBm A 2.439508000 GHz Temp 2 [T1 OBW]
-11.53 dBm LVL
2.440528000 GHz

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:51:30

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2480

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1 T1
T2

Marker 1 [T1 ] 2.87 dBm
2.479968000 GHz
OBW 1.012000000 MHz Temp 1 [T1 OBW]
-10.73 dBm A 2.479512000 GHz Temp 2 [T1 OBW]
-12.20 dBm LVL
2.480524000 GHz

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:53:11
BLE 2M_Ant1_2402

Page 15 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

-10

T1

Marker 1 [T1 ] 0.45 dBm
2.401968000 GHz
OBW 2.036000000 MHz Temp 1 [T1 OBW]
-13.98 dBm A 2.401008000 GHz Temp 2 [T1 OBW]
-13.85 dBm LVL
2.403044000 GHz
T2

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:57:50

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2440

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

Marker 1 [T1 ] 1.13 dBm
2.439968000 GHz
OBW 2.036000000 MHz Temp 1 [T1 OBW]
-13.43 dBm A 2.439008000 GHz Temp 2 [T1 OBW]
-13.20 dBm LVL
2.441044000 GHz

-10

T1

T2

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 15:02:08

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2480

* Att 20 dB

* RBW 30 kHz * VBW 100 kHz
SWT 20 ms

1

Marker 1 [T1 ] 0.67 dBm
2.479960000 GHz
OBW 2.032000000 MHz Temp 1 [T1 OBW]
-13.93 dBm A 2.479008000 GHz Temp 2 [T1 OBW]
-13.62 dBm LVL
2.481040000 GHz

-10

T1

T2

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 15:04:24

Page 16 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

6 dB bandwidth: Left side:

Ref 20 dBm 20 Offset 1.5 dB

10
1 PK VIEW
0

D1 0.778 dBm

BLE 1M_Ant1_2402

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] 0.05 dB
700.000000000 kHz
Marker 1 [T1 ] 0.58 dBm
2.401652000 GHz A Marker 2 [T1 ]
6.78 dBm 2.401760000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:23:57

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 1.42 dBm

BLE 1M_Ant1_2440

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] -0.00 dB
704.000000000 kHz
Marker 1 [T1 ] 1.27 dBm
2.439644000 GHz A Marker 2 [T1 ]
7.42 dBm 2.439760000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:26:49

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 1.005 dBm

BLE 1M_Ant1_2480

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] 0.11 dB
684.000000000 kHz
Marker 1 [T1 ] 0.76 dBm
2.479660000 GHz A Marker 2 [T1 ]
7.01 dBm 2.479760000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:28:30
BLE 2M_Ant1_2402

Page 17 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB

* Att 20 dB

10
1 PK VIEW
0

D1 0.764 dBm

2 1

-10

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] -0.60 dB
1.184000000 MHz
Marker 1 [T1 ] 0.67 dBm
2.401412000 GHz A Marker 2 [T1 ]
6.76 dBm 2.401504000 GHz
LVL

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:32:12

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 1.427 dBm

BLE 2M_Ant1_2440

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] 0.00 dB
1.184000000 MHz
Marker 1 [T1 ] 1.32 dBm
2.439408000 GHz A Marker 2 [T1 ]
7.43 dBm 2.439500000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:34:25

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 0.998 dBm

BLE 2M_Ant1_2480

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] 0.03 dB
1.184000000 MHz
Marker 1 [T1 ] 0.90 dBm
2.479408000 GHz A Marker 2 [T1 ]
7.00 dBm 2.479508000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:36:14

Page 18 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Right side:

Ref 20 dBm 20 Offset 1.5 dB

10
1 PK VIEW
0

D1 0.233 dBm

BLE 1M_Ant1_2402

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] -0.19 dB
700.000000000 kHz
Marker 1 [T1 ] 0.13 dBm
2.401664000 GHz A Marker 2 [T1 ]
6.23 dBm 2.401756000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:48:57

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 0.881 dBm

BLE 1M_Ant1_2440

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] -0.06 dB
692.000000000 kHz
Marker 1 [T1 ] 0.73 dBm
2.439660000 GHz A Marker 2 [T1 ]
6.88 dBm 2.439760000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:51:13

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 0.415 dBm

BLE 1M_Ant1_2480

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] -0.09 dB
700.000000000 kHz
Marker 1 [T1 ] -0.02 dBm
2.479648000 GHz A Marker 2 [T1 ]
6.42 dBm 2.479760000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:52:54
BLE 2M_Ant1_2402

Page 19 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB

* Att 20 dB

10
1 PK VIEW
0

D1 0.224 dBm

2 1

-10

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] -0.07 dB
1.184000000 MHz
Marker 1 [T1 ] 0.16 dBm
2.401416000 GHz A Marker 2 [T1 ]
6.22 dBm 2.401508000 GHz
LVL

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:57:33

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 0.907 dBm

BLE 2M_Ant1_2440

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] 0.14 dB
1.184000000 MHz
Marker 1 [T1 ] 0.58 dBm
2.439416000 GHz A Marker 2 [T1 ]
6.91 dBm 2.439512000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 15:01:51

Ref 20 dBm 20 Offset 1.6 dB

10
1 PK VIEW
0

D1 0.47 dBm

BLE 2M_Ant1_2480

* Att 20 dB
2 1

* RBW 100 kHz * VBW 300 kHz
SWT 5 ms
3

Delta 3 [T1 ] 0.31 dB
1.180000000 MHz
Marker 1 [T1 ] 0.09 dBm
2.479416000 GHz A Marker 2 [T1 ]
6.47 dBm 2.479512000 GHz
LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 15:04:08

Page 20 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

5. Maximum Peak Output Power
5.1. Block diagram of test setup
Same with 4.1
5.2. Limits
For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt. If transmitting antennas of directional gain greater than 6dBi are used, the conducted output power from the intentional radiator shall be reduced below the stated values as appropriate, by the amount in dB that the directional gain of the antenna exceeds 6 dBi, the e.i.r.p shall not exceed 4W.

5.3. Test procedure

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Set the spectrum analyzer as follows:

RBW:

DTS bandwidth

VBW:

3 x RBW

Span

3 x RBW

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Allow the trace to stabilize, Use the instrument's band/channel power measurement function

with the band limits set equal to the DTS bandwidth edges measure out the conducted output

power.

Page 21 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

5.4. Test result
Left side:

Mode GFSK 1M GFSK 2M

Freq. (MHz)
2402 2440 2480 2402 2440 2480

Conducted Output Power (dBm) 8.10 8.72 8.31 8.19 8.84 8.42

Limit (dBm)
30 30 30 30 30 30

Mode

Freq. (MHz)

EIRP (dBm)

Limit (dBm)

2402

7.51

36

GFSK 1M

2440

8.13

36

2480

7.72

36

2402

7.60

36

GFSK 2M

2440

8.25

36

2480

7.83

36

Note: EIRP (dBm)=Conducted Output Power (dBm)+ Antenna Gain (dBi)

Right side: Mode
GFSK 1M
GFSK 2M

Freq. (MHz)
2402 2440 2480 2402 2440 2480

Conducted Output Power (dBm) 7.59 8.21 7.75 7.63 8.24 7.83

Limit (dBm)
30 30 30 30 30 30

Mode

Freq. (MHz)

EIRP (dBm)

Limit (dBm)

2402

7.25

36

GFSK 1M

2440

7.87

36

2480

7.41

36

2402

7.29

36

GFSK 2M

2440

7.90

36

2480

7.49

36

Note: EIRP (dBm)=Conducted Output Power (dBm)+ Antenna Gain (dBi)

Verdict Pass Pass Pass Pass Pass Pass
Verdict Pass Pass Pass Pass Pass Pass
Verdict Pass Pass Pass Pass Pass Pass
Verdict Pass Pass Pass Pass Pass Pass

Page 22 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

5.5. Original test data

Left side:

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

BLE 1M_Ant1_2402

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.10 dBm
2.401890000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 16:24:26

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 1M_Ant1_2440

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.72 dBm
2.439700000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 16:27:21

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 1M_Ant1_2480

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.31 dBm
2.479770000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 16:28:59
BLE 2M_Ant1_2402

Page 23 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB 1

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

-10

-20

-30

-40

-50

-60

-70
-80 Center 2.402 GHz

1 MHz/

Marker 1 [T1 ] 8.19 dBm
2.401530000 GHz A
LVL
3DB
Span 10 MHz

Date: 28.MAY.2022 16:32:41

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2440

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.84 dBm
2.439570000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 16:34:54

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2480

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.42 dBm
2.479540000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 16:36:43

Page 24 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Right side:

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

BLE 1M_Ant1_2402

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 7.59 dBm
2.401730000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.402 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 14:49:46

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 1M_Ant1_2440

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.21 dBm
2.439750000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 14:51:42

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 1M_Ant1_2480

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 7.75 dBm
2.479680000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 14:53:23
BLE 2M_Ant1_2402

Page 25 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

1

-10

-20

-30

-40

-50

-60

-70
-80 Center 2.402 GHz

1 MHz/

Marker 1 [T1 ] 7.63 dBm
2.401650000 GHz A
LVL
3DB
Span 10 MHz

Date: 28.MAY.2022 14:58:02

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2440

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 8.24 dBm
2.439460000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.44 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 15:02:20

Ref 20 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2480

* Att 20 dB

* RBW 3 MHz * VBW 10 MHz
SWT 5 ms

Marker 1 [T1 ] 7.83 dBm
2.479530000 GHz

1

A

LVL

-10

-20

-30 -40

3DB

-50

-60

-70
-80 Center 2.48 GHz

1 MHz/

Span 10 MHz

Date: 28.MAY.2022 15:04:37

Page 26 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

6. Power Spectral Density
6.1. Block diagram of test setup
Same with 4.1
6.2. Limits
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission.

6.3. Test procedure

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Set the spectrum analyzer as follows:

Center frequency

DTS Channel center frequency

RBW:

3 kHz  RBW  100 kHz

VBW:

 3RBW

Span

1.5 times the DTS bandwidth

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Allow the trace to stabilize, use the peak marker function to determine the maximum

amplitude level within the RBW.

(4) If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.

Page 27 of 97

Dongguan Dongdian Testing Service Co., Ltd.

6.4. Test result
Left side: EUT Set Mode GFSK 1M
GFSK 2M Limit: <8 dBm/3 kHz Right side:
EUT Set Mode GFSK 1M
GFSK 2M Limit: <8 dBm/3 kHz

Antenna ANT1 ANT1 ANT1 ANT1 ANT1 ANT1
Antenna ANT1 ANT1 ANT1 ANT1 ANT1 ANT1

Report No.: DDT-R22030409-2E02

Channel CH0 CH19 CH39 CH0 CH19 CH39

Result (dBm/3 kHz) -9.84 -9.07 -9.43 -14.9 -14.39 -14.74
Verdict: Pass

Channel CH0 CH19 CH39 CH0 CH19 CH39

Result (dBm/3 kHz) -10.47 -9.65 -9.97 -15.37 -14.98 -15.36
Verdict: Pass

Page 28 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

6.5. Original test data

Left side:

Ref 21.5 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2402

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 225 ms

Marker 1 [T1 ] -9.84 dBm
2.401836000 GHz

A

LVL 1

-20

-30 -40

3DB

-50

-60

-70

Center 2.402 GHz

200 kHz/

Span 2 MHz

Date: 28.MAY.2022 16:24:37

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2440

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 225 ms

Marker 1 [T1 ] -9.07 dBm
2.439834000 GHz

A

LVL 1

-20

-30 -40

3DB

-50

-60

-70

Center 2.44 GHz

200 kHz/

Span 2 MHz

Date: 28.MAY.2022 16:27:32

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2480

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 225 ms

Marker 1 [T1 ] -9.43 dBm
2.479836000 GHz

A

LVL 1

-20

-30 -40

3DB

-50

-60

-70

Center 2.48 GHz

200 kHz/

Span 2 MHz

Date: 28.MAY.2022 16:29:10
BLE 2M_Ant1_2402

Page 29 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 21.5 dBm 20 Offset 1.5 dB

* Att 20 dB

10
1 PK VIEW
0

* RBW 3 kHz * VBW 10 kHz
SWT 450 ms

-10 1
-20

-30

-40

-50

-60

-70

Marker 1 [T1 ] -14.90 dBm
2.401948000 GHz A
LVL
3DB

Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:32:52

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2440

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 450 ms

Marker 1 [T1 ] -14.39 dBm
2.439948000 GHz

A

LVL

-10

1

-20

-30 -40

3DB

-50

-60

-70

Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:35:05

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2480

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 450 ms

Marker 1 [T1 ] -14.74 dBm
2.479948000 GHz

A

LVL

-10

1

-20

-30 -40

3DB

-50

-60

-70

Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 16:36:55

Page 30 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Right side:

Ref 21.5 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2402

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 225 ms

Marker 1 [T1 ] -10.47 dBm
2.401842000 GHz

A

LVL 1

-20

-30 -40

3DB

-50

-60

-70

Center 2.402 GHz

200 kHz/

Span 2 MHz

Date: 28.MAY.2022 14:49:57

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2440

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 225 ms

Marker 1 [T1 ] -9.65 dBm
2.439842000 GHz

A

LVL 1

-20

-30 -40

3DB

-50

-60

-70

Center 2.44 GHz

200 kHz/

Span 2 MHz

Date: 28.MAY.2022 14:51:53

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0
-10

BLE 1M_Ant1_2480

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 225 ms

Marker 1 [T1 ] -9.97 dBm
2.479842000 GHz

A

LVL 1

-20

-30 -40

3DB

-50

-60

-70

Center 2.48 GHz

200 kHz/

Span 2 MHz

Date: 28.MAY.2022 14:53:34
BLE 2M_Ant1_2402

Page 31 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 21.5 dBm 20 Offset 1.5 dB

* Att 20 dB

10
1 PK VIEW
0

* RBW 3 kHz * VBW 10 kHz
SWT 450 ms

-10 1
-20

-30

-40

-50

-60

-70

Marker 1 [T1 ] -15.37 dBm
2.401956000 GHz A
LVL
3DB

Center 2.402 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 14:58:13

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2440

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 450 ms

Marker 1 [T1 ] -14.98 dBm
2.439956000 GHz

A

LVL

-10 1
-20

-30 -40

3DB

-50

-60

-70

Center 2.44 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 15:02:32

Ref 21.6 dBm 20 Offset 1.6 dB
10 1 PK VIEW
0

BLE 2M_Ant1_2480

* Att 20 dB

* RBW 3 kHz * VBW 10 kHz
SWT 450 ms

Marker 1 [T1 ] -15.36 dBm
2.479956000 GHz

A

LVL

-10 1
-20

-30 -40

3DB

-50

-60

-70

Center 2.48 GHz

400 kHz/

Span 4 MHz

Date: 28.MAY.2022 15:04:48

Page 32 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

7. Band Edge Compliance (Conducted Method)

7.1. Block diagram of test setup
Same with 4.1
7.2. Limits
In any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power.

7.3. Test procedure

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Establish a reference level by using the following procedure:

RBW:

100 kHz

VBW:

300 kHz

Span

Encompass frequency range to be measured

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Allow the trace to stabilize, use the peak marker function to determine the maximum peak

power level to establish the reference level.

7.4. Test result

Left side:

EUT Set Mode GFSK 1M GFSK 2M

CH or Frequency CH0 CH39 CH0 CH39

Measured Range 2.310 GHz - 2.405 GHz 2.470 GHz - 2.550 GHz 2.310 GHz - 2.405 GHz 2.470 GHz - 2.550 GHz

Right side: EUT Set Mode GFSK 1M
GFSK 2M

CH or Frequency CH0 CH39 CH0 CH39

Measured Range 2.310 GHz - 2.405 GHz 2.470 GHz - 2.550 GHz 2.310 GHz - 2.405 GHz 2.470 GHz - 2.550 GHz

Verdict Pass Pass Pass Pass
Verdict Pass Pass Pass Pass

Page 33 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

7.5. Original test data

Left side:

BLE 1M_Ant1_Low_2402

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB

-10

D1 -13.18 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -45.48 dBm
2.399900000 GHz
Marker 1 [T1 ] 6.82 dBm
2.4018000100 GHz A Marker 2 [T1 ]
-44.10 dBm 2.400000000 GHz
LVL Marker 3 [T1 ]
-59.73 dBm 2.390000000 GHz

-20

-30 -40 -50 -60

42 3

3DB

-70
-80 Start 2.31 GHz

10 MHz/

Stop 2.41 GHz

Date: 28.MAY.2022 16:24:49

BLE 1M_Ant1_High_2480

Ref 20 dBm 20 Offset 1.6 dB

10

1

1 PK VIEW
0

* Att 20 dB

-10

D1 -13.08 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -54.50 dBm
2.483500000 GHz
Marker 1 [T1 ] 6.92 dBm
2.479700000 GHz A Marker 2 [T1 ]
-54.50 dBm 2.483500000 GHz
LVL Marker 3 [T1 ]
-60.13 dBm 2.500000000 GHz

-20

-30 -40

3DB

-50

24

3 -60

-70
-80 Start 2.47 GHz

10 MHz/

Stop 2.57 GHz

Date: 28.MAY.2022 16:29:22

BLE 2M_Ant1_Low_2402

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB

-10

D1 -13.35 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -31.94 dBm
2.399900000 GHz
Marker 1 [T1 ] 6.65 dBm
2.4015000100 GHz A Marker 2 [T1 ]
-27.46 dBm 2.400000000 GHz
LVL Marker 3 [T1 ]
-60.79 dBm 2.390000000 GHz

-20 -30 -40

2 4
3DB

-50
3 -60

-70
-80 Start 2.31 GHz

10 MHz/

Stop 2.41 GHz

Date: 28.MAY.2022 16:33:04
BLE 2M_Ant1_High_2480

Page 34 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Right side:

Ref 20 dBm 20 Offset 1.6 dB

10

1

1 PK VIEW
0

* Att 20 dB

-10 -20

D1 -13.14 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -52.41 dBm
2.483900000 GHz

Marker 1 [T1 ]

6.86 dBm

2.479400000 GHz A

Marker 2 [T1 ]

-54.08 dBm

2.483500000 GHz

Marker 3 [T1 ]

LVL

-58.87 dBm

2.500000000 GHz

-30

-40

-50

4 2

3

-60

3DB

-70
-80 Start 2.47 GHz

10 MHz/

Stop 2.57 GHz

Date: 28.MAY.2022 16:37:07

BLE 1M_Ant1_Low_2402

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB

-10

D1 -13.92 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -46.74 dBm
2.399900000 GHz
Marker 1 [T1 ] 6.08 dBm
2.402000000 GHz A 1
Marker 2 [T1 ] -47.93 dBm
2.400000000 GHz LVL
Marker 3 [T1 ] -59.43 dBm
2.390000000 GHz

-20

-30 -40 -50 -60

42 3

3DB

-70
-80 Start 2.31 GHz

10 MHz/

Stop 2.41 GHz

Date: 28.MAY.2022 14:50:09

BLE 1M_Ant1_High_2480

Ref 20 dBm 20 Offset 1.6 dB

10

1

1 PK VIEW
0

* Att 20 dB

-10

D1 -13.66 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -54.84 dBm
2.483600000 GHz
Marker 1 [T1 ] 6.34 dBm
2.479700000 GHz A Marker 2 [T1 ]
-55.60 dBm 2.483500000 GHz
LVL Marker 3 [T1 ]
-59.26 dBm 2.500000000 GHz

-20

-30 -40

3DB

-50 24 3
-60

-70
-80 Start 2.47 GHz

10 MHz/

Stop 2.57 GHz

Date: 28.MAY.2022 14:53:46
BLE 2M_Ant1_Low_2402

Page 35 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 20 dBm 20 Offset 1.5 dB
10 1 PK VIEW
0

* Att 20 dB

-10 -20

D1 -13.78 dBm

-30

-40

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -32.98 dBm
2.399900000 GHz

Marker 1 [T1 ]

6.22 dBm

2.401600000 GHz A 1
Marker 2 [T1 ]

-28.07 dBm

2.400000000 GHz

Marker 3 [T1 ]

LVL

-59.47 dBm

2.390000000 GHz

2 4
3DB

-50
3 -60

-70
-80 Start 2.31 GHz

10 MHz/

Stop 2.41 GHz

Date: 28.MAY.2022 14:58:25

BLE 2M_Ant1_High_2480

Ref 20 dBm 20 Offset 1.6 dB

10

1

1 PK VIEW
0

* Att 20 dB

-10

D1 -13.65 dBm

* RBW 100 kHz * VBW 300 kHz
SWT 10 ms

Marker 4 [T1 ] -53.06 dBm
2.483600000 GHz
Marker 1 [T1 ] 6.35 dBm
2.479400000 GHz A Marker 2 [T1 ]
-54.10 dBm 2.483500000 GHz
LVL Marker 3 [T1 ]
-59.38 dBm 2.500000000 GHz

-20

-30 -40

3DB

-50

24

3 -60

-70
-80 Start 2.47 GHz

10 MHz/

Stop 2.57 GHz

Date: 28.MAY.2022 15:05:00

Page 36 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

8. Radiated Emission
8.1. Block diagram of test setup
In 3 m Anechoic Chamber, test setup diagram for 9 kHz - 30 MHz:

3m
EUT and Support System

1m
1. m 1.0m W 0.8m H

Turntable

EM Test Recei er

C System

In 3 m Anechoic Chamber, test setup diagram for 30 MHz - 1 GHz:

A TE A E E AT
3m

AR ES FR M 1 T METERS

EUT and Support System

1. m 1.0m W 0.8m H

Turntable

EM Test Recei er

C System

Page 37 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

In 3 m Anechoic Chamber, test setup diagram for frequency above 1 GHz:

A TE A E E AT
3m

AR ES FR M 1 T METERS

1. m 1.0m W 1. m H

EUT and Support System
Turntable

re Amplifier

EM Test Recei er

C System

Note: For harmonic emissions test an appropriate high pass filter was inserted in the input port of AMP.

8.2. Limit

(1) FCC 15.205 Restricted frequency band

MHz

MHz

0.090-0.110

16.42-16.423

10.495-0.505

16.69475-16.69525

2.1735-2.1905

16.80425-16.80475

4.125-4.128

25.5-25.67

4.1772&4.17775

37.5-38.25

4.2072&4.20775

73-74.6

6.215-6.218

74.8-75.2

6.26775-6.26825

108-121.94

6.31175-6.31225

123-138

8.291-8.294

149.9-150.05

8.362-8.366

156.52475-156.52525

8.37625-8.38675

156.7-156.9

8.41425-8.41475

162.0125-167.17

12.29-12.293

167.72-173.2

12.51975-12.52025

240-285

12.57675-12.57725

322-335.4

13.36-13.41

MHz

399.9-410 608-614
960-1240 1300-1427 1435-1626.5 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2690-2900 3260-3267 3332-3339 3345.8-3358 3600-4400

GHz

4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5
9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5
(2)

1Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz. 2Above 38.6

Page 38 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

RSS-Gen section 8.10 Restricted frequency bands*

MHz

MHz

MHz

0.090-0.110

12.51975-12.52025

0.495-0.505

12.57675-12.57725

2.1735-2.1905

13.36-13.41

3.020-3.026

16.42-16.423

4.125-4.128

16.69475-16.69525

4.1772&4.17775

16.80425-16.80475

4.2072&4.20775

25.5-25.67

5.677-5.683

37.5-38.25

6.215-6.218

73-74.6

6.26775-6.26825

74.8-75.2

6.31175-6.31225

108-138

8.291-8.294

149.9-150.05

8.362-8.366

156.52475-156.52525

8.37625-8.38675

156.7-156.9

8.41425-8.41475

162.0125-167.17

12.29-12.293

167.72-173.2

240-285 322-335.4 399.9-410
608-614 960-1427 1435-1626.5 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2655-2900 3260-3267 3332-3339 3345.8-3358

GHz

3.5-4.4 4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5
9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5 Above 38.6

* Certain frequency bands listed in table and in bands above 38.6 GHz are designated for licence-exempt applications. These frequency bands and the requirements that apply to related devices are set out in the 200 and 300 series of RSSs.

(2) FCC 15.209 Limit & RSS-Gen section 8.9 Limit

FREQUENCY MHz

DISTANCE Meters

0.009 ~ 0.490

300

0.490 ~ 1.705

30

1.705 ~ 30.0

30

30 ~ 88

3

88 ~ 216

3

216 ~ 960

3

960 ~ 1000

3

Above 1000

3

FIELD STRENGTHS LIMIT

V/m

dB(V)/m

2400/F(kHz)

67.6-20log(F)

24000/F(kHz)

87.6-20log(F)

30

29.54

100

40.0

150

43.5

200

46.0

500

54.0

74.0 dB(V)/m (Peak)

54.0 dB(V)/m (Average)

Note: (1) The emission limits shown in the above table are based on measurements employing a CISPR QP detector except for the frequency bands 9 - 90 kHz, 110 - 490 kHz and above 1000 MHz. Radiated emissions limits in these three bands are based on measurements employing an average detector. (2) At frequencies below 30 MHz, measurement may be performed at a distance closer than that specified, and the limit at closer measurement distance can be extrapolated by below formula: Limit3m(dBuV/m) = Limit30m(dBuV/m) + 40Log(30m/3m)

(3) Limit for this EUT The emissions appearing within 15.205 restricted frequency bands shall not exceed the limits

Page 39 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

shown in 15.209, and the emissions appearing within RSS-Gen section 8.10 Restricted frequency bands shall not exceed the limits shown in RSS-Gen section 8.9, all the other emissions shall be at least 20 dB below the fundamental emissions or comply with 15.209 limits and RSS-Gen section 8.9 limits.

8.3. Test Procedure

(1) EUT was placed on a non-metallic table, 80 cm above the ground plane inside a semi-anechoic chamber for below 1 G and 150 cm above the ground plane inside a semi-anechoic chamber for above 1 G.
(2) Test antenna was located 3 m from the EUT on an adjustable mast, and the antenna used as below table.

Test frequency range

Test antenna used

Test antenna distance

9 kHz - 30 MHz

Active Loop antenna

3 m

30 MHz - 1 GHz

Trilog Broadband Antenna

3 m

1 GHz - 18 GHz

Double Ridged Horn Antenna

3 m

(1 GHz - 18 GHz)

18 GHz - 40 GHz

Horn Antenna

1 m

(18 GHz - 40 GHz)

According ANSI C63.10:2013 clause 6.4.4.2 and 6,5.3, for measurements below 30 MHz, the

loop antenna was positioned with its plane vertical from the EUT and rotated about its vertical

axis for maximum response at each azimuth position around the EUT. And the loop antenna also

is positioned with its plane horizontal at the specified distance from the EUT. The center of the

loop is 1 m above the ground. For measurement above 30 MHz, the Trilog Broadband Antenna or

Horn Antenna was located 3 m from EUT, Measurements were made with the antenna positioned

in both the horizontal and vertical planes of Polarization, and the measurement antenna was

varied from 1 m to 4 m. in height above the reference ground plane to obtain the maximum signal

strength.

(3) Below pre-scan procedure was first performed in order to find prominent frequency spectrum

radiated emissions from 9 kHz to 25 GHz:

(a) Scanning the peak frequency spectrum with the antenna specified in step (3), and the EUT

was rotated 360 degree, the antenna height was varied from 1 m to 4 m (Except loop antenna, it's

fixed 1 m above ground.)

(b) Change work frequency or channel of device if practicable.

(c) Change modulation type of device if practicable.

(d) Change power supply range from 85% to 115% of the rated supply voltage

(e) Rotated EUT though three orthogonal axes to determine the attitude of EUT arrangement

produces highest emissions.

Spectrum frequency from 9 kHz to 25 GHz (tenth harmonic of fundamental frequency) was

investigated, and no any obvious emission were detected from 9 kHz to 30 MHz and 18 GHz

to 25 GHz, so below final test was performed with frequency range from 30 MHz to 18 GHz.

Page 40 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

(4) For final emissions measurements at each frequency of interest, the EUT was rotated and the

antenna height was varied between 1 m and 4 m in order to maximize the emission.

Measurements in both horizontal and vertical polarities were made and the data was recorded.

In order to find the maximum emission, the relative positions of equipments and all of the

interface cables were changed according to ANSI C63.10:2013 on Radiated Emission test.

(5) The emissions from 9 kHz to 1 GHz were measured based on CISPR QP detector except for

the frequency bands 9 - 90 kHz, 110 - 490 kHz, for emissions from 9 kHz - 90 kHz, 110 kHz -

490 kHz and above 1 GHz were measured based on average detector, for emissions above 1

GHz, peak emissions also be measured and need comply with Peak limit.

(6) The emissions from 9 kHz to 1 GHz, QP or average values were measured with EMI receiver

with below RBW

Frequency band

RBW

9 kHz - 150 kHz

200 Hz

150 kHz - 30 MHz

9 kHz

30 MHz - 1 GHz

120 kHz

For emissions above 1 GHz, both Peak and Average level were measured with Spectrum

Analyzer, and the RBW is set at 1 MHz, VBW is set at 3 MHz for Peak measure; According

ANSI C63.10:2013 clause 4.1.4.2.2 procedure for average measure.

(8) X axis, Y axis, Z axis are tested, and worse setup X axis is reported.

8.4. Test result
Pass. (See below detailed test result)
All the emissions except fundamental emission from 9 kHz to 25 GHz were comply with 15.209 limits and RSS-Gen section 8.9 limits. Note1: According exploratory test, the emission levels are 20 dB below the limit detected from 9 kHz to 30 MHz and 18 GHz to 25 GHz, so the final test was performed with frequency range from 30 MHz to 18 GHz and recorded in below. Note2: For emissions below 1 GHz, according exploratory explorer test, when change Tx mode and channel, have no distinct influence on emissions level, so for emissions below 1 GHz, the final test was only performed with EUT working in Left side GFSK Tx 2440 MHz mode. Note3: For emissions above 1 GHz. If peak results comply with AV limit, AV Result is deemed to comply with AV limit. The final test was only performed with EUT working in Left side GFSK Tx mode.

Page 41 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Radiated Emission test (below 1 GHz)
TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-13

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC BELOW 1G.EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Test Mode

: Tx mode

Condition

: Temp:21.2°C,Humi:63.5%,Press:100.1kPa Antenna/Distance : 2021 VLUB 9163 3#/3m/VERTICAL

Memo

: BLE 1M

Data: 3

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 46.02 97.46 199.29 329.04 590.97 906.48

Read Level (dBµV) 4.16 3.46 4.05 3.73 4.50 4.80

Antenna Factor (dB/m) 14.59 11.45 11.97 14.06 18.94 22.23

Cable Loss
dB 3.65 3.97 4.45 4.93 5.71 6.49

Result Level (dBµV/m) 22.40 18.88 20.47 22.72 29.15 33.52

Limit Line (dBµV/m) 40.00 43.50 43.50 46.00 46.00 46.00

Over Limit (dB) -17.60 -24.62 -23.03 -23.28 -16.85 -12.48

Detector
QP QP QP QP QP QP

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss. 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Page 42 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-13

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC BELOW 1G.EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Test Mode

: Tx mode

Condition

: Temp:21.2°C,Humi:63.5%,Press:100.1kPa Antenna/Distance : 2021 VLUB 9163 3#/3m/HORIZONTAL

Memo

: BLE 1M

Data: 4

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 44.74 97.46 195.14 329.04 511.84 945.44

Read Level (dBµV) 3.16 3.46 4.16 3.73 3.92 4.92

Antenna Factor (dB/m) 15.07 11.45 11.71 14.06 17.14 22.20

Cable Loss
dB 3.64 3.97 4.43 4.93 5.50 6.56

Result Level (dBµV/m) 21.87 18.88 20.30 22.72 26.56 33.68

Limit Line (dBµV/m) 40.00 43.50 43.50 46.00 46.00 46.00

Over Limit (dB) -18.13 -24.62 -23.20 -23.28 -19.44 -12.32

Detector
QP QP QP QP QP QP

Polarization
HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss. 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Page 43 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-13

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC BELOW 1G.EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Test Mode

: Tx mode

Condition

: Temp:21.2°C,Humi:63.5%,Press:100.1kPa Antenna/Distance : 2021 VLUB 9163 3#/3m/VERTICAL

Memo

: BLE 2M

Data: 5

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 45.38 98.49 197.20 420.58 605.66 916.07

Read Level (dBµV) 4.07 4.08 3.59 3.52 3.94 4.99

Antenna Factor (dB/m) 14.91 11.50 11.82 15.91 19.20 22.40

Cable Loss
dB 3.65 3.97 4.44 5.22 5.75 6.51

Result Level (dBµV/m) 22.63 19.55 19.85 24.65 28.89 33.90

Limit Line (dBµV/m) 40.00 43.50 43.50 46.00 46.00 46.00

Over Limit (dB) -17.37 -23.95 -23.65 -21.35 -17.11 -12.10

Detector
QP QP QP QP QP QP

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss. 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Page 44 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-13

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC BELOW 1G.EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Test Mode

: Tx mode

Condition

: Temp:21.2°C,Humi:63.5%,Press:100.1kPa Antenna/Distance : 2021 VLUB 9163 3#/3m/HORIZONTAL

Memo

: BLE 2M

Data: 6

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 45.38 94.10 193.77 345.60 485.61 925.76

Read Level (dBµV) 4.07 4.84 4.74 3.78 4.14 5.50

Antenna Factor (dB/m) 14.91 11.01 11.45 14.75 16.51 22.40

Cable Loss
dB 3.65 3.95 4.43 4.98 5.44 6.53

Result Level (dBµV/m) 22.63 19.80 20.62 23.51 26.09 34.43

Limit Line (dBµV/m) 40.00 43.50 43.50 46.00 46.00 46.00

Over Limit (dB) -17.37 -23.70 -22.88 -22.49 -19.91 -11.57

Detector
QP QP QP QP QP QP

Polarization
HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss. 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Page 45 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Radiated Emission test (above 1 GHz)
TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Test Mode

: Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2402 1M

Data: 19

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1410.00 1596.00 1976.00 2378.00 2426.00 2890.00

Read Level (dBµV) 50.73 53.94 49.40 55.89 54.68 48.72

Antenna Factor (dB/m) 25.42 25.65 26.64 27.38 27.47 29.08

PRM Factor
dB 38.52 38.79 39.36 39.59 39.61 39.85

Cable Loss
dB 1.33 1.42 1.59 1.71 1.72 1.84

Filter Factor
dB 0.57 0.61 0.68 0.72 0.73 0.78

Result Level (dBµV/m) 39.53 42.83 38.95 46.11 44.99 40.57

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -34.47 -31.17 -35.05 -27.89 -29.01 -33.43

Detector
Peak Peak Peak Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 46 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2402 1M

Data: 20

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1596.00 2078.00 2274.00 2378.00 2426.00 2822.00

Read Level (dBµV) 53.94 49.35 52.48 58.89 57.44 49.58

Antenna Factor (dB/m) 25.65 26.84 27.19 27.38 27.47 28.82

PRM Factor
dB 38.79 39.44 39.54 39.59 39.61 39.81

Cable Loss
dB 1.42 1.62 1.68 1.71 1.72 1.82

Filter Factor
dB 0.61 0.69 0.71 0.72 0.73 0.77

Result Level (dBµV/m) 42.83 39.06 42.52 49.11 47.75 41.18

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -31.17 -34.94 -31.48 -24.89 -26.25 -32.82

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 47 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2440 1M

Data: 23

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1598.00 2038.00 2230.00 2416.00 2464.00 2660.00

Read Level (dBµV) 53.71 48.80 51.00 53.75 54.23 50.67

Antenna Factor (dB/m) 25.65 26.77 27.11 27.45 27.54 28.21

PRM Factor
dB 38.80 39.42 39.52 39.61 39.63 39.73

Cable Loss
dB 1.42 1.61 1.66 1.72 1.73 1.78

Filter Factor
dB 0.61 0.68 0.71 0.73 0.73 0.75

Result Level (dBµV/m) 42.59 38.44 40.96 44.04 44.60 41.68

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -31.41 -35.56 -33.04 -29.96 -29.40 -32.32

Detector
Peak Peak Peak Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 48 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2440 1M

Data: 24

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1598.00 1908.00 2230.00 2416.00 2464.00 2660.00

Read Level (dBµV) 53.71 48.89 51.00 57.96 57.03 50.67

Antenna Factor (dB/m) 25.65 26.46 27.11 27.45 27.54 28.21

PRM Factor
dB 38.80 39.26 39.52 39.61 39.63 39.73

Cable Loss
dB 1.42 1.56 1.66 1.72 1.73 1.78

Filter Factor
dB 0.61 0.66 0.71 0.73 0.73 0.75

Result Level (dBµV/m) 42.59 38.31 40.96 48.25 47.40 41.68

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -31.41 -35.69 -33.04 -25.75 -26.60 -32.32

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 49 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2480 1M

Data: 25

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1598.00 1984.00 2152.00 2456.00 2504.00 2736.00

Read Level (dBµV) 49.94 49.05 48.95 53.90 54.88 49.03

Antenna Factor (dB/m) 25.65 26.66 26.97 27.52 27.62 28.50

PRM Factor
dB 38.80 39.38 39.48 39.63 39.65 39.77

Cable Loss
dB 1.42 1.59 1.64 1.73 1.74 1.80

Filter Factor
dB 0.61 0.68 0.70 0.73 0.74 0.76

Result Level (dBµV/m) 38.82 38.60 38.78 44.25 45.33 40.32

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -35.18 -35.40 -35.22 -29.75 -28.67 -33.68

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 50 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2480 1M

Data: 26

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1594.00 2106.00 2412.00 2456.00 2504.00 2736.00

Read Level (dBµV) 54.10 49.46 52.82 53.90 54.88 49.03

Antenna Factor (dB/m) 25.64 26.89 27.44 27.52 27.62 28.50

PRM Factor
dB 38.79 39.45 39.61 39.63 39.65 39.77

Cable Loss
dB 1.42 1.63 1.72 1.73 1.74 1.80

Filter Factor
dB 0.61 0.69 0.73 0.73 0.74 0.76

Result Level (dBµV/m) 42.98 39.22 43.10 44.25 45.33 40.32

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -31.02 -34.78 -30.90 -29.75 -28.67 -33.68

Detector
Peak Peak Peak Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 51 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery Condition : Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2402 2M

Data: 29

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1598.00 1920.00 2282.00 2378.00 2426.00 2522.00

Read Level (dBµV) 50.34 49.46 52.36 59.51 60.23 51.68

Antenna Factor (dB/m) 25.65 26.49 27.21 27.38 27.47 27.68

PRM Factor
dB 38.80 39.28 39.54 39.59 39.61 39.66

Cable Loss
dB 1.42 1.56 1.68 1.71 1.72 1.75

Filter Factor
dB 0.61 0.67 0.71 0.72 0.73 0.74

Result Level (dBµV/m) 39.22 38.90 42.42 49.73 50.54 42.19

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -34.78 -35.10 -31.58 -24.27 -23.46 -31.81

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 52 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2402 2M

Data: 30

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1594.00 1920.00 2282.00 2378.00 2426.00 2522.00

Read Level (dBµV) 54.08 49.46 52.36 59.51 60.23 51.68

Antenna Factor (dB/m) 25.64 26.49 27.21 27.38 27.47 27.68

PRM Factor
dB 38.79 39.28 39.54 39.59 39.61 39.66

Cable Loss
dB 1.42 1.56 1.68 1.71 1.72 1.75

Filter Factor
dB 0.61 0.67 0.71 0.72 0.73 0.74

Result Level (dBµV/m) 42.96 38.90 42.42 49.73 50.54 42.19

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -31.04 -35.10 -31.58 -24.27 -23.46 -31.81

Detector
Peak Peak Peak Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 53 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2440 2M

Data: 33

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1598.00 1906.00 2344.00 2416.00 2464.00 2734.00

Read Level (dBµV) 49.95 49.31 50.97 57.30 57.74 48.95

Antenna Factor (dB/m) 25.65 26.46 27.32 27.45 27.54 28.49

PRM Factor
dB 38.80 39.26 39.57 39.61 39.63 39.77

Cable Loss
dB 1.42 1.56 1.70 1.72 1.73 1.80

Filter Factor
dB 0.61 0.66 0.72 0.73 0.73 0.76

Result Level (dBµV/m) 38.83 38.73 41.14 47.59 48.11 40.23

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -35.17 -35.27 -32.86 -26.41 -25.89 -33.77

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 54 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2440 2M

Data: 34

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1214.00 1598.00 2096.00 2416.00 2464.00 2840.00

Read Level (dBµV) 49.81 55.13 49.53 57.30 57.74 48.98

Antenna Factor (dB/m) 25.46 25.65 26.87 27.45 27.54 28.89

PRM Factor
dB 38.22 38.80 39.45 39.61 39.63 39.82

Cable Loss
dB 1.22 1.42 1.63 1.72 1.73 1.83

Filter Factor
dB 0.54 0.61 0.69 0.73 0.73 0.77

Result Level (dBµV/m) 38.81 44.01 39.27 47.59 48.11 40.65

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -35.19 -29.99 -34.73 -26.41 -25.89 -33.35

Detector
Peak Peak Peak Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 55 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2480 2M

Data: 35

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1216.00 1594.00 2028.00 2382.00 2504.00 2974.00

Read Level (dBµV) 49.53 53.87 48.71 51.15 50.08 48.64

Antenna Factor (dB/m) 25.46 25.64 26.75 27.39 27.62 29.40

PRM Factor
dB 38.22 38.79 39.41 39.59 39.65 39.89

Cable Loss
dB 1.22 1.42 1.61 1.71 1.74 1.86

Filter Factor
dB 0.54 0.61 0.68 0.72 0.74 0.79

Result Level (dBµV/m) 38.53 42.75 38.34 41.38 40.53 40.80

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -35.47 -31.25 -35.66 -32.62 -33.47 -33.20

Detector
Peak Peak Peak Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 56 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2480 2M

Data: 36

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 1216.00 1594.00 2382.00 2456.00 2504.00 2864.00

Read Level (dBµV) 49.53 53.87 51.15 53.96 53.95 48.61

Antenna Factor (dB/m) 25.46 25.64 27.39 27.52 27.62 28.98

PRM Factor
dB 38.22 38.79 39.59 39.63 39.65 39.83

Cable Loss
dB 1.22 1.42 1.71 1.73 1.74 1.83

Filter Factor
dB 0.54 0.61 0.72 0.73 0.74 0.78

Result Level (dBµV/m) 38.53 42.75 41.38 44.31 44.40 40.37

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -35.47 -31.25 -32.62 -29.69 -29.60 -33.63

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 57 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2402

Data: 45

Item
(Mark) 1 2 3 4 5 6

Freq.
(MHz) 4800.00 7725.00 10350.00 13095.00 16875.00 17850.00

Read Level (dBµV) 53.73 47.99 46.92 46.29 43.43 41.17

Antenna Factor (dB/m) 32.46 36.67 38.82 39.68 38.35 41.57

PRM Factor
dB 40.36 39.77 40.46 40.33 40.07 40.61

Cable Loss
dB 2.47 3.16 3.67 4.32 4.72 4.92

Filter Factor
dB 2.16 2.27 2.45 2.95 3.46 3.75

Result Level (dBµV/m) 50.46 50.32 51.40 52.91 49.89 50.80

Limit Line (dBµV/m) 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -23.54 -23.68 -22.60 -21.09 -24.11 -23.20

Detector Polarization

Peak Peak Peak Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 58 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2402

Data: 46

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 6000.00 8430.00 11010.00 14370.00 14370.00 16500.00 17685.00

Read Level (dBµV) 50.83 46.79 46.54 42.09 45.46 44.36 42.27

Antenna Factor (dB/m) 34.00 37.69 39.29 39.90 39.90 37.90 40.55

PRM Factor
dB 40.50 39.84 40.20 39.66 39.66 40.00 40.51

Cable Loss
dB 3.03 3.22 3.80 4.40 4.40 4.73 4.87

Filter Factor
dB 2.80 2.24 2.38 2.80 2.80 3.32 3.70

Result Level (dBµV/m) 50.16 50.10 51.81 49.53 52.90 50.31 50.88

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -23.84 -23.90 -22.19 -4.47 -21.10 -23.69 -23.12

Detector
Peak Peak Peak Average Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 59 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2440

Data: 47

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 4995.00 7335.00 10575.00 12720.00 12720.00 16485.00 17685.00

Read Level (dBµV) 49.12 48.45 46.71 42.11 47.28 44.63 42.08

Antenna Factor (dB/m) 33.08 36.27 39.04 39.26 39.26 37.90 40.55

PRM Factor
dB 40.40 39.73 40.37 40.32 40.32 40.00 40.51

Cable Loss
dB 2.54 3.10 3.69 4.01 4.01 4.73 4.87

Filter Factor
dB 2.19 2.27 2.42 2.80 2.80 3.31 3.70

Result Level (dBµV/m) 46.53 50.36 51.49 47.86 53.03 50.57 50.69

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -27.47 -23.64 -22.51 -6.14 -20.97 -23.43 -23.31

Detector
Peak Peak Peak Average Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 60 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2440

Data: 48

Item
(Mark) 1 2 3 4 5 6 7 8

Freq.
(MHz) 4875.00 6930.00 9150.00 11730.00 11730.00 14580.00 14580.00 17310.00

Read Level (dBµV) 54.37 48.05 46.13 42.19 47.54 41.36 45.13 43.63

Antenna Factor (dB/m) 32.70 35.89 38.42 39.09 39.09 39.84 39.84 39.06

PRM Factor
dB 40.38 39.76 40.01 40.13 40.13 39.64 39.64 40.29

Cable Loss
dB 2.49 3.06 3.42 4.01 4.01 4.37 4.37 4.78

Filter Factor
dB 2.17 2.30 2.23 2.39 2.39 2.74 2.74 3.60

Result Level (dBµV/m) 51.35 49.54 50.19 47.55 52.90 48.67 52.44 50.78

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 54.00 74.00 74.00

Over Limit (dB) -22.65 -24.46 -23.81 -6.45 -21.10 -5.33 -21.56 -23.22

Detector Polarization

Peak Peak Peak Average Peak Average Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 61 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2480

Data: 49

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 4950.00 7530.00 11040.00 13800.00 13800.00 16050.00 17715.00

Read Level (dBµV) 51.33 47.71 46.52 42.11 45.66 45.56 42.84

Antenna Factor (dB/m) 32.94 36.44 39.28 39.94 39.94 37.90 40.73

PRM Factor
dB 40.39 39.75 40.20 39.84 39.84 39.91 40.53

Cable Loss
dB 2.52 3.14 3.81 4.31 4.31 4.61 4.88

Filter Factor
dB 2.18 2.27 2.38 2.91 2.91 3.14 3.71

Result Level (dBµV/m) 48.58 49.81 51.79 49.43 52.98 51.30 51.63

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -25.42 -24.19 -22.21 -4.57 -21.02 -22.70 -22.37

Detector Polarization

Peak Peak Peak Average Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 62 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2480

Data: 50

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 5055.00 6930.00 9465.00 13605.00 13605.00 15765.00 17700.00

Read Level (dBµV) 48.83 48.74 46.65 42.82 46.19 44.81 41.82

Antenna Factor (dB/m) 33.07 35.89 38.67 39.98 39.98 38.32 40.64

PRM Factor
dB 40.41 39.76 40.23 39.98 39.98 39.83 40.52

Cable Loss
dB 2.54 3.06 3.60 4.10 4.10 4.58 4.88

Filter Factor
dB 2.22 2.30 2.32 2.92 2.92 3.00 3.71

Result Level (dBµV/m) 46.25 50.23 51.01 49.84 53.21 50.88 50.53

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -27.75 -23.77 -22.99 -4.16 -20.79 -23.12 -23.47

Detector
Peak Peak Peak Average Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 63 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2402 2M

Data: 51

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 5100.00 7500.00 10875.00 14565.00 14565.00 16815.00 17880.00

Read Level (dBµV) 49.66 48.74 46.39 42.13 45.56 44.17 40.94

Antenna Factor (dB/m) 33.04 36.40 39.22 39.85 39.85 38.28 41.76

PRM Factor
dB 40.41 39.75 40.25 39.64 39.64 40.06 40.63

Cable Loss
dB 2.55 3.14 3.77 4.37 4.37 4.72 4.93

Filter Factor
dB 2.25 2.27 2.39 2.74 2.74 3.44 3.76

Result Level (dBµV/m) 47.09 50.80 51.52 49.45 52.88 50.55 50.76

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -26.91 -23.20 -22.48 -4.55 -21.12 -23.45 -23.24

Detector
Peak Peak Peak Average Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 64 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2402 2M

Data: 52

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 4800.00 7500.00 10365.00 13530.00 13530.00 16110.00 17745.00

Read Level (dBµV) 53.20 48.35 47.24 41.29 45.68 44.61 42.49

Antenna Factor (dB/m) 32.46 36.40 38.84 39.99 39.99 37.90 40.92

PRM Factor
dB 40.36 39.75 40.45 40.03 40.03 39.92 40.55

Cable Loss
dB 2.47 3.14 3.67 4.02 4.02 4.63 4.89

Filter Factor
dB 2.16 2.27 2.44 2.93 2.93 3.16 3.72

Result Level (dBµV/m) 49.93 50.41 51.74 48.20 52.59 50.38 51.47

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -24.07 -23.59 -22.26 -5.80 -21.41 -23.62 -22.53

Detector Polarization

Peak Peak Peak Average Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 65 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2440 2M

Data: 53

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 4875.00 7200.00 9900.00 13515.00 13515.00 15975.00 17700.00

Read Level (dBµV) 52.84 47.54 47.57 41.33 45.74 44.57 41.92

Antenna Factor (dB/m) 32.70 36.16 38.46 40.00 40.00 37.94 40.64

PRM Factor
dB 40.38 39.72 40.53 40.04 40.04 39.89 40.52

Cable Loss
dB 2.49 3.07 3.66 4.01 4.01 4.60 4.88

Filter Factor
dB 2.17 2.26 2.45 2.93 2.93 3.11 3.71

Result Level (dBµV/m) 49.82 49.31 51.61 48.23 52.64 50.33 50.63

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -24.18 -24.69 -22.39 -5.77 -21.36 -23.67 -23.37

Detector Polarization

Peak Peak Peak Average Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 66 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2440 2M

Data: 54

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 4320.00 7575.00 10755.00 13575.00 13575.00 16170.00 17730.00

Read Level (dBµV) 49.58 48.54 46.28 41.33 46.00 45.08 41.61

Antenna Factor (dB/m) 31.36 36.49 39.15 39.99 39.99 37.90 40.83

PRM Factor
dB 40.26 39.76 40.30 40.00 40.00 39.93 40.54

Cable Loss
dB 2.27 3.15 3.74 4.07 4.07 4.64 4.88

Filter Factor
dB 2.09 2.27 2.40 2.93 2.93 3.19 3.71

Result Level (dBµV/m) 45.04 50.69 51.27 48.32 52.99 50.88 50.49

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -28.96 -23.31 -22.73 -5.68 -21.01 -23.12 -23.51

Detector
Peak Peak Peak Average Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 67 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2480 2M

Data: 55

Item
(Mark) 1 2 3 4 5 6 7 8

Freq.
(MHz) 4950.00 7185.00 11115.00 11115.00 13920.00 13920.00 15840.00 17745.00

Read Level (dBµV) 49.86 47.83 42.15 46.83 41.39 45.01 45.64 42.71

Antenna Factor (dB/m) 32.94 36.15 39.23 39.23 39.92 39.92 38.19 40.92

PRM Factor
dB 40.39 39.72 40.19 40.19 39.76 39.76 39.85 40.55

Cable Loss
dB 2.52 3.06 3.84 3.84 4.44 4.44 4.59 4.89

Filter Factor
dB 2.18 2.26 2.38 2.38 2.90 2.90 3.04 3.72

Result Level (dBµV/m) 47.11 49.58 47.41 52.09 48.89 52.51 51.61 51.69

Limit Line (dBµV/m) 74.00 74.00 54.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -26.89 -24.42 -6.59 -21.91 -5.11 -21.49 -22.39 -22.31

Detector
Peak Peak Average Peak Average Peak Peak Peak

Polarization
VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 68 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-17

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery Condition : Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2480 2M

Data: 56

Item
(Mark) 1 2 3 4 5 6 7

Freq.
(MHz) 4950.00 7530.00 10065.00 13035.00 13035.00 16155.00 17205.00

Read Level (dBµV) 51.85 49.10 47.96 42.61 47.00 44.68 44.61

Antenna Factor (dB/m) 32.94 36.44 38.48 39.63 39.63 37.90 38.87

PRM Factor
dB 40.39 39.75 40.57 40.38 40.38 39.93 40.22

Cable Loss
dB 2.52 3.14 3.67 4.37 4.37 4.64 4.76

Filter Factor
dB 2.18 2.27 2.47 2.96 2.96 3.18 3.57

Result Level (dBµV/m) 49.10 51.20 52.01 49.19 53.58 50.47 51.59

Limit Line (dBµV/m) 74.00 74.00 74.00 54.00 74.00 74.00 74.00

Over Limit (dB) -24.90 -22.80 -21.99 -4.81 -20.42 -23.53 -22.41

Detector Polarization

Peak Peak Peak Average Peak Peak Peak

HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 69 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

9. RF Conducted Spurious Emissions

9.1. Block diagram of test setup
Same as section 4.1
9.2. Limits
In any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power.

9.3. Test procedure

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Establish a reference level by using the following procedure:

Center frequency

Test frequency

RBW:

100 kHz

VBW:

300 kHz

Span

Wide enough to capture the peak level of the in-band emission

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Allow the trace to stabilize, use the peak marker function to determine the maximum peak

power level to establish the reference level.

(4) Set the spectrum analyzer as follows:

RBW:

100 kHz

VBW:

300 kHz

Span

Encompass frequency range to be measured

Number of measurement points

span/RBW

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(5) Allow the trace to stabilize, use the peak marker function to determine the maximum

amplitude of all unwanted emissions outside of the authorized frequency band

Page 70 of 97

Dongguan Dongdian Testing Service Co., Ltd.

9.4. Test result
Left side: Mode
GFSK 1M
GFSK 2M
Right side: Mode
GFSK 1M
GFSK 2M

Freq. (MHz) 2402 2440 2480 2402 2440 2480
Freq. (MHz) 2402 2440 2480 2402 2440 2480

Report No.: DDT-R22030409-2E02
Verdict Pass Pass Pass Pass Pass Pass
Verdict Pass Pass Pass Pass Pass Pass

Page 71 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

9.5. Original test data

Left side:

BLE 1M_Ant1_2402_0~Reference

Ref 30 dBm 30 Offset 1.5 dB

* Att 30 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.69 dBm
2.401754808 GHz

20

1 PK

VIEW

10

1

A LVL

0

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.402 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 16:25:34

BLE 1M_Ant1_2402_30~1000

Ref 20 dBm 20 Offset 1.5 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -51.77 dBm
87.521000000 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.31 dBm

-30
-40
1 -50

3DB

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 16:25:41

BLE 1M_Ant1_2402_1000~26500

Ref 20 dBm 20 Offset 1.5 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.65 dBm
25.472350000 GHz
Marker 1 [T1 ] 3.69 dBm
2.401650000 GHz A

LVL

-10 -20

D1 -13.31 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 16:26:10
BLE 1M_Ant1_2440_0~Reference

Page 72 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 7.28 dBm
2.439754808 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.44 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 16:27:38

BLE 1M_Ant1_2440_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -52.28 dBm
126.030000000 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -12.72 dBm

-30

-40

-50

1

3DB

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 16:27:43

BLE 1M_Ant1_2440_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1 0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.32 dBm
25.275150000 GHz
Marker 1 [T1 ] 7.02 dBm
2.439900000 GHz A

LVL

-10 -20

D1 -12.72 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 16:28:06
BLE 1M_Ant1_2480_0~Reference

Page 73 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.85 dBm
2.479745192 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.48 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 16:29:31

BLE 1M_Ant1_2480_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -53.53 dBm
165.509000000 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.15 dBm

-30 -40

3DB

-50

1

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 16:29:39

BLE 1M_Ant1_2480_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -56.83 dBm
26.461750000 GHz
Marker 1 [T1 ] 3.90 dBm
2.479000000 GHz A

LVL

-10 -20

D1 -13.15 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 16:30:25
BLE 2M_Ant1_2402_0~Reference

Page 74 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.5 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.71 dBm
2.401500000 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.402 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 16:33:15

BLE 2M_Ant1_2402_30~1000

Ref 20 dBm 20 Offset 1.5 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -54.55 dBm
87.294666667 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.29 dBm

-30 -40

3DB

-50 1 -60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 16:33:24

BLE 2M_Ant1_2402_1000~26500

Ref 20 dBm 20 Offset 1.5 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -56.18 dBm
26.177850000 GHz
Marker 1 [T1 ] 3.37 dBm
2.400800000 GHz A

LVL

-10 -20

D1 -13.29 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 16:33:59
BLE 2M_Ant1_2440_0~Reference

Page 75 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 7.37 dBm
2.439504808 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.44 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 16:35:14

BLE 2M_Ant1_2440_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -54.15 dBm
126.288666667 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -12.63 dBm

-30 -40

3DB

-50

1

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 16:35:22

BLE 2M_Ant1_2440_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.86 dBm
26.400550000 GHz
Marker 1 [T1 ] 4.77 dBm
2.439900000 GHz A

LVL

-10 -20

D1 -12.63 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 16:35:45
BLE 2M_Ant1_2480_0~Reference

Page 76 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.87 dBm
2.479500000 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.48 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 16:37:18

BLE 2M_Ant1_2480_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -50.29 dBm
165.282666667 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.13 dBm

-30
-40 1
-50

3DB

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 16:37:23

BLE 2M_Ant1_2480_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -56.96 dBm
1.435200000 GHz
Marker 1 [T1 ] 2.31 dBm
2.479850000 GHz A

LVL

-10 -20

D1 -13.13 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 16:38:20

Page 77 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Right side:

BLE 1M_Ant1_2402_0~Reference

Ref 30 dBm 30 Offset 1.5 dB

* Att 30 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.13 dBm
2.401754808 GHz

20

1 PK

VIEW

10

1

A LVL

0

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.402 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 14:50:16

BLE 1M_Ant1_2402_30~1000

Ref 20 dBm 20 Offset 1.5 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -50.67 dBm
87.553333333 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.87 dBm

-30
-40 1
-50

3DB

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 14:50:20

BLE 1M_Ant1_2402_1000~26500

Ref 20 dBm 20 Offset 1.5 dB

1 PK MAXH

10 1 0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.29 dBm
2.523200000 GHz
Marker 1 [T1 ] 5.44 dBm
2.401650000 GHz A

LVL

-10 -20

D1 -13.87 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 14:50:43
BLE 1M_Ant1_2440_0~Reference

Page 78 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.78 dBm
2.439759615 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.44 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 14:51:59

BLE 1M_Ant1_2440_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -53.68 dBm
125.545000000 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.22 dBm

-30 -40

3DB

-50

1

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 14:52:04

BLE 1M_Ant1_2440_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1 0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.72 dBm
19.895500000 GHz
Marker 1 [T1 ] 5.36 dBm
2.439900000 GHz A

LVL

-10 -20

D1 -13.22 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 14:52:27
BLE 1M_Ant1_2480_0~Reference

Page 79 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.34 dBm
2.479764423 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.48 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 14:53:53

BLE 1M_Ant1_2480_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -52.74 dBm
165.573666667 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.66 dBm

-30

-40

-50

1

3DB

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 14:53:57

BLE 1M_Ant1_2480_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.12 dBm
8.487650000 GHz
Marker 1 [T1 ] 4.68 dBm
2.479850000 GHz A

LVL

-10 -20

D1 -13.66 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 14:55:44
BLE 2M_Ant1_2402_0~Reference

Page 80 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.5 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.16 dBm
2.401509615 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.402 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 14:59:42

BLE 2M_Ant1_2402_30~1000

Ref 20 dBm 20 Offset 1.5 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -55.07 dBm
87.294666667 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.84 dBm

-30 -40

3DB

-50 1
-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 14:59:47

BLE 2M_Ant1_2402_1000~26500

Ref 20 dBm 20 Offset 1.5 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.35 dBm
22.710700000 GHz
Marker 1 [T1 ] 3.48 dBm
2.401650000 GHz A

LVL

-10 -20

D1 -13.84 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 15:01:26
BLE 2M_Ant1_2440_0~Reference

Page 81 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.87 dBm
2.439509615 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.44 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 15:02:43

BLE 2M_Ant1_2440_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -57.58 dBm
207.995000000 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.13 dBm

-30 -40

3DB

-50 1
-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 15:02:52

BLE 2M_Ant1_2440_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -57.48 dBm
23.790200000 GHz
Marker 1 [T1 ] 3.46 dBm
2.439050000 GHz A

LVL

-10 -20

D1 -13.13 dBm

-30 -40

3DB

-50 2
-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 15:03:41
BLE 2M_Ant1_2480_0~Reference

Page 82 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

Ref 30 dBm 30 Offset 1.6 dB
20 1 PK VIEW
10

* Att 30 dB 1

0

* RBW 100 kHz * VBW 300 kHz
SWT 2.5 ms

Marker 1 [T1 ] 6.36 dBm
2.479504808 GHz

A

LVL

-10

-20 -30

3DB

-40

-50

-60
-70 Center 2.48 GHz

300 kHz/

Span 3 MHz

Date: 28.MAY.2022 15:05:10

BLE 2M_Ant1_2480_30~1000

Ref 20 dBm 20 Offset 1.6 dB

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 125 ms

Marker 1 [T1 ] -49.76 dBm
165.315000000 MHz

10
1 PK MAXH
0

A LVL

-10 -20

D1 -13.64 dBm

-30
-40 1
-50

3DB

-60

-70
-80 Start 30 MHz

97 MHz/

Stop 1 GHz

Date: 28.MAY.2022 15:05:15

BLE 2M_Ant1_2480_1000~26500

Ref 20 dBm 20 Offset 1.6 dB

1 PK MAXH

10 1
0

* Att 20 dB

* RBW 100 kHz * VBW 300 kHz
SWT 2.6 s

Marker 2 [T1 ] -53.60 dBm
2.338750000 GHz
Marker 1 [T1 ] 3.56 dBm
2.479850000 GHz A

LVL

-10 -20

D1 -13.64 dBm

-30 -40

3DB

-50 2

-60

-70
-80 Start 1 GHz

2.55 GHz/

Stop 26.5 GHz

Date: 28.MAY.2022 15:05:56

Page 83 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

10. Emissions in Restricted Frequency Bands
10.1. Block diagram of test setup

A TE A E E AT
3m

AR ES FR M 1 T METERS

1. m 1.0m W 1. m H

EUT and Support System
Turntable

re Amplifier

EM Test Recei er

C System

10.2. Limit
All restriction band should comply with 15.209 and RSS-Gen section 8.9 limits, other emission should be at least 20 dB below the fundamental.
10.3. Test procedure
Same with clause 8.3 except change investigated frequency range from 2310 MHz to 2410 MHz and 2475 MHz to 2500 MHz. Remark: All restriction band have been tested, and only the worst case is shown in report.
10.4. Test result
Pass. (See below detailed test result) The final test was only performed with EUT working in Left side GFSK Tx mode.

Page 84 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2402 1M

Data: 21

Item
(Mark) 1 2

Freq.
(MHz) 2377.80 2390.00

Read Level (dBµV)
59.63
52.78

Antenna Factor (dB/m)
27.38
27.40

PRM Factor
dB
39.59
39.60

Cable Loss
dB
1.71
1.71

Filter Factor
dB
0.72
0.72

Result Level (dBµV/m)
49.85
43.01

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-24.15
-30.99

Detector Polarization

Peak Peak

HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 85 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2402 1M

Data: 22

Item
(Mark) 1 2

Freq.
(MHz) 2377.80 2390.00

Read Level (dBµV)
59.63
52.78

Antenna Factor (dB/m)
27.38
27.40

PRM Factor
dB
39.59
39.60

Cable Loss
dB
1.71
1.71

Filter Factor
dB
0.72
0.72

Result Level (dBµV/m)
49.85
43.01

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-24.15
-30.99

Detector
Peak Peak

Polarization
VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 86 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2480 1M

Data: 27

Item
(Mark) 1 2

Freq.
(MHz) 2483.50 2484.15

Read Level (dBµV)
53.16
54.95

Antenna Factor (dB/m)
27.57
27.57

PRM Factor
dB
39.64
39.64

Cable Loss
dB
1.74
1.74

Filter Factor
dB
0.73
0.73

Result Level (dBµV/m)
43.56
45.35

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-30.44
-28.65

Detector
Peak Peak

Polarization
VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 87 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2480 1M

Data: 28

Item
(Mark) 1 2

Freq.
(MHz) 2483.50 2484.55

Read Level (dBµV)
54.07
55.51

Antenna Factor (dB/m)
27.57
27.57

PRM Factor
dB
39.64
39.64

Cable Loss
dB
1.74
1.74

Filter Factor
dB
0.73
0.73

Result Level (dBµV/m)
44.47
45.91

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-29.53
-28.09

Detector Polarization

Peak Peak

HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 88 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2402 2M

Data: 31

Item
(Mark) 1 2

Freq.
(MHz) 2378.10 2390.00

Read Level (dBµV)
55.51
49.90

Antenna Factor (dB/m)
27.38
27.40

PRM Factor
dB
39.59
39.60

Cable Loss
dB
1.71
1.71

Filter Factor
dB
0.72
0.72

Result Level (dBµV/m)
45.73
40.13

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-28.27
-33.87

Detector
Peak Peak

Polarization
VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 89 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2402 2M

Data: 32

Item
(Mark) 1 2

Freq.
(MHz) 2377.70 2390.00

Read Level (dBµV)
59.47
51.64

Antenna Factor (dB/m)
27.38
27.40

PRM Factor
dB
39.59
39.60

Cable Loss
dB
1.71
1.71

Filter Factor
dB
0.72
0.72

Result Level (dBµV/m)
49.69
41.87

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-24.31
-32.13

Detector Polarization

Peak Peak

HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 90 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Model Number : VIBE FLEX

Power Supply : Battery

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa

Test Mode

: Tx mode

Antenna/Distance

:

2021 BBHA 9120D 3#/3m/HORIZONTAL

Memo

: BLE 2480 2M

Data: 37

Item
(Mark) 1 2

Freq.
(MHz) 2483.50 2484.05

Read Level (dBµV)
55.77
55.42

Antenna Factor (dB/m)
27.57
27.57

PRM Factor
dB
39.64
39.64

Cable Loss
dB
1.74
1.74

Filter Factor
dB
0.73
0.73

Result Level (dBµV/m)
46.17
45.82

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-27.83
-28.18

Detector Polarization

Peak Peak

HORIZONTAL HORIZONTAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 91 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-009 Radiated Emission Test Result

Test Site Test Date

: DDT 3m Chamber 3# : 2022-05-15

D:\E3 6.111\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC ABOVE 1G .EM6

Tested By

: James Gan

EUT

: BLUETOOTH HEADSET

Power Supply : Battery

Model Number Test Mode

: VIBE FLEX : Tx mode

Condition

: Temp:22.3°C,Humi:72.1%,Press:100.1kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL

Memo

: BLE 2480 2M

Data: 38

Item
(Mark) 1 2

Freq.
(MHz) 2483.50 2484.05

Read Level (dBµV)
55.77
55.42

Antenna Factor (dB/m)
27.57
27.57

PRM Factor
dB
39.64
39.64

Cable Loss
dB
1.74
1.74

Filter Factor
dB
0.73
0.73

Result Level (dBµV/m)
46.17
45.82

Limit Line (dBµV/m)
74.00
74.00

Over Limit (dB)
-27.83
-28.18

Detector
Peak Peak

Polarization
VERTICAL VERTICAL

Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto.

Page 92 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

11. Power Line Conducted Emission
11.1. Block diagram of test setup

C System

10cm

EUT

AE

80cm

Recei er

80cm 80cm

S 1

80cm

0 impedance
S 2

11.2. Power line conducted emission limits

Frequency
150 kHz ~ 500 kHz 500 kHz ~ 5 MHz
5 MHz ~ 30 MHz

Quasi-Peak Level dB(V)
66 ~ 56* 56 60

Note 1: * Decreasing linearly with logarithm of frequency. Note 2: The lower limit shall apply at the transition frequencies.

Average Level dB(V)
56 ~ 46* 46 50

11.3. Test procedure
The EUT and Support equipment, if needed, were put placed on a non-metallic table, 80 cm above the ground plane. Configuration EUT to simulate typical usage as described in clause 2.4 and test equipment as described in clause 10.2 of this report. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10. All support equipment power received from a second LISN. Emissions were measured on each current carrying line of the EUT using an EMI Test Receiver connected to the LISN powering the EUT. The Receiver scanned from 150 kHz to 30 MHz for emissions in each of the test modes. During the above scans, the emissions were maximized by cable manipulation. The test mode(s) described in clause 2.4 were scanned during the preliminary test. After the preliminary scan, we found the test mode producing the highest emission level. The EUT configuration and worse cable configuration of the above highest emission levels were recorded for reference of the final test. EUT and support equipment were set up on the test bench as per the configuration with highest

Page 93 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

emission level in the preliminary test. A scan was taken on both power lines, Neutral and Line, recording at least the six highest emissions. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. The test data of the worst-case condition(s) was recorded. The bandwidth of test receiver is set at 9 kHz.
11.4. Test result
Pass. (See below detailed test result)
Note1: All emissions not reported below are too low against the prescribed limits. ote2: "-----" means eak detection; "-----" means A erage detection.
Note3: Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worse case.

Page 94 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-010 Conducted Emission Test Result

Test Site

: DDT 5# Shield Room

Test Date

: 2022-05-12

EUT

: BLUETOOTH HEADSET

Power Supply : AC 240V/60Hz

Condition

: Temp:20.5°C,Humi:61.2%,Press:101.2kPa

D:\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC.EM6 Tested By : James Gan

Model Number

: VIBE FLEX

Test Mode : Tx mode

LISN

: 2021 ENV 216 3#/NEUTRAL

Memo

:

Data: 6

Item
(Mark) 1 2 3 4 5 6 7 8 9 10 11 12

Freq.
(MHz) 0.21 0.21 0.90 0.90 1.49 1.49 3.21 3.21 4.77 4.77 10.79 10.79

Read Level (dBµV) 7.28 -0.11 21.37 11.62 6.05 -3.35 9.66 -1.21 9.88 -1.45 2.67 -3.38

LISN Factor
(dB) 9.39 9.39 9.41 9.41 9.33 9.33 9.20 9.20 9.26 9.26 9.38 9.38

Cable Loss (dB) 9.83 9.83 9.85 9.85 9.89 9.89 9.93 9.93 9.93 9.93 9.95 9.95

Result Level (dBµV) 26.50 19.11 40.63 30.88 25.27 15.87 28.79 17.92 29.07 17.74 22.00 15.95

Limit Line (dBµV) 63.10 53.10 56.00 46.00 56.00 46.00 56.00 46.00 56.00 46.00 60.00 50.00

Over Limit (dB) -36.60 -33.99 -15.37 -15.12 -30.73 -30.13 -27.21 -28.08 -26.93 -28.26 -38.00 -34.05

Detector
QP Average
QP Average
QP Average
QP Average
QP Average
QP Average

Phase
NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL

Note: 1. Result Level = Read Level +LISN Factor + Pulse Limiter Factor + Cable loss. 2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 200 Hz (9 kHz--150 kHz), 9 kHz (150 kHz--30 MHz). 4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.

Page 95 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

TR-4-E-010 Conducted Emission Test Result

Test Site

: DDT 5# Shield Room

Test Date

: 2022-05-12

EUT

: BLUETOOTH HEADSET

Power Supply : AC 240V/60Hz

Condition

: Temp:20.5°C,Humi:61.2%,Press:101.2kPa

D:\2022 Report Data\Q22030409-2E VIBE FLEX 2\FCC.EM6 Tested By : James Gan

Model Number

: VIBE FLEX

Test Mode : Tx mode

LISN

: 2021 ENV 216 3#/LINE

Memo

:

Data: 8

Item
(Mark) 1 2 3 4 5 6 7 8 9 10 11 12

Freq.
(MHz) 0.21 0.21 0.32 0.32 0.90 0.90 2.64 2.64 4.77 4.77 10.85 10.85

Read Level (dBµV) 4.32 -4.88 5.45 -3.93 17.44 6.19 2.51 -7.11 3.43 -9.47 0.43 -4.27

LISN Factor
(dB) 9.50 9.50 9.50 9.50 9.43 9.43 9.46 9.46 9.46 9.46 9.40 9.40

Cable Loss (dB) 9.83 9.83 9.84 9.84 9.85 9.85 9.92 9.92 9.93 9.93 9.95 9.95

Result Level (dBµV) 23.65 14.45 24.79 15.41 36.72 25.47 21.89 12.27 22.82 9.92 19.78 15.08

Limit Line (dBµV) 63.10 53.10 59.62 49.62 56.00 46.00 56.00 46.00 56.00 46.00 60.00 50.00

Over Limit (dB) -39.45 -38.65 -34.83 -34.21 -19.28 -20.53 -34.11 -33.73 -33.18 -36.08 -40.22 -34.92

Detector
QP Average
QP Average
QP Average
QP Average
QP Average
QP Average

Note: 1. Result Level = Read Level +LISN Factor + Pulse Limiter Factor + Cable loss. 2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 200 Hz (9 kHz--150 kHz), 9 kHz (150 kHz--30 MHz). 4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.

Phase
LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE

Page 96 of 97

Dongguan Dongdian Testing Service Co., Ltd.

Report No.: DDT-R22030409-2E02

12. Antenna Requirements
12.1. Limit
For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And according to FCC 47 CFR Section 15.247 (b), if transmitting antennas of directional gain greater than 6 dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi.
For intentional device, according to RSS-Gen issue 5 section 6.8. The applicant for equipment certification shall provide a list of all antenna types that may be used with the transmitter, where applicable (i.e. for transmitters with detachable antenna), indicating the maximum permissible antenna gain (in dBi) and the required impedance for each antenna. The test report shall demonstrate the compliance of the transmitter with the limit for maximum equivalent isotropically radiated power (e.i.r.p.) specified in the applicable RSS, when the transmitter is equipped with any antenna type, selected from this list.
12.2. Result
The product is that no antenna other than that furnished by the responsible party shall be used with the device, the maximum peak gain of the left side transmit antenna is -0.59 dBi and right side is -0.34 dBi.

END OF REPORT

Page 97 of 97



Related FCC IDs: