Shenzhen Sunspring Electronics Co., Ltd.
Keyboard
OJWCG107C
Violet Wang
Test Report-JAV
ARTIKA FOR LIVING INC. OUT-DIC 2AYFPOUT-DIC 2AYFPOUTDIC out dic
download (pdf)
OUT-DIC Dixon Outdoor 3 Cct by ARTIKA FOR LIVING
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 18 Pages, 1.03MB
Document DEVICE REPORTOUT-DIC-Test-Report-ARTIKA-FOR-LIVING-2ayfpout-dic-ex-1-7Page 1 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE FCC Part 15, Subpart B, Class B ARTIKA FOR LIVING INC. Dixon outdoor 3 CCT Test Model: OUT-DIC-HD2BL Additional Model No.: Please Refer to Page 7 Prepared for Address : ARTIKA FOR LIVING INC. : 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Prepared by Address Tel Fax Web Mail : Shenzhen LCS Compliance Testing Laboratory Ltd. : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China : (+86)755-82591330 : (+86)755-82591332 : www.LCS-cert.com : [email protected] Date of receipt of test sample Number of tested samples Sample No. Serial number Date of Test Date of Report : April 29, 2022 :2 : 220429086A-1,220429086A-2 : Prototype : April 29, 2022 ~ May 10, 2022 : May 11, 2022 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 2 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE FCC Part 15, Subpart B, Class B FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Report Reference No. .............: LCS220429086AE Date Of Issue.............................. : May 11, 2022 Testing Laboratory Name...... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address........................................ : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure.... : Full application of Harmonised standards Partial application of Harmonised standards Other standard testing method Applicant's Name..................... : ARTIKA FOR LIVING INC. Address........................................ : 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Test Specification Standard...................................... : FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Test Report Form No................. : LCSEMC-1.0 TRF Originator............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF................................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. is acknowledged as copyright owner and source of the material. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description............. : Dixon outdoor 3 CCT Trade Mark.................................. : ARTIKA Test Model .................................. : OUT-DIC-HD2BL Ratings......................................... : Input: AC 120V, 60Hz, Max 11W Result ..........................................: Positive Compiled by: Supervised by: Approved by: Diamond Lu/ Administrator Jin Wang/ Technique principal Gavin Liang/ Manager Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 3 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE FCC SDOC-- TEST REPORT Test Report No. : LCS220429086AE May 11, 2022 Date of issue Test Model ........................ : OUT-DIC-HD2BL EUT.................................... : Dixon outdoor 3 CCT Applicant........................... : ARTIKA FOR LIVING INC. Address.............................. : 1756 50th avenue, Lachine, Qc, CanadaH8T 2V5 Telephone.......................... : / Fax..................................... : / Manufacturer..................... : Ningbo Shenghe Lighting Co., LTD. Address.............................. : No.311 Penglai Road, Xiangshan Economic development Zone, Ningbo, Zhejiang, 315700 Telephone.......................... : / Fax..................................... : / Factory.............................. : Ningbo Shenghe Lighting Co., LTD. Address.............................. : No.311 Penglai Road, Xiangshan Economic development Zone, Ningbo, Zhejiang, 315700 Telephone.......................... : / Fax..................................... : / Test Result according to the standards on page 6: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 4 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE Report Version 000 Revision History Issue Date May 11, 2022 Revision Content Initial Issue Revised By -- Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 5 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE TABLE OF CONTENTS Test Report Description Page 1. SUMMARY OF STANDARDS AND RESULTS .................................................................. 6 1.1. Description of Standards and Results ......................................................................................... 6 2. GENERAL INFORMATION .....................................................................................................7 2.1. Description of Device (EUT) ..........................................................................................................7 2.2. Support Equipment List ..................................................................................................................8 2.3 External I/O Cable ............................................................................................................................8 2.4. Description of Test Facility ............................................................................................................ 8 2.4. Statement of the Measurement Uncertainty ............................................................................... 9 2.5. Measurement Uncertainty ............................................................................................................. 9 3. TEST RESULTS ......................................................................................................................10 3.1. POWER LINE CONDUCTED EMISSION MEASUREMENT .................................................10 Note: Measured = Reading Level + Correct Factor, Over = Measured - Limit ........................... 13 3.2. Radiated emission Measurement ...............................................................................................14 4. TEST SETUP PHOTOGRAPHS OF EUT ...........................................................................18 5. EXTERIOR PHOTOGRAPHS OF THE EUT ......................................................................18 6. INTERIOR PHOTOGRAPHS OF THE EUT ....................................................................... 18 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 6 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 1. SUMMARY OF STANDARDS AND RESULTS 1.1. Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below. Description of Test Item Conducted disturbance at mains terminals Radiated disturbance EMISSION Standard Limits Results FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Class B FCC 47 CFR Part 15 Subpart B, Class B, ANSI C63.4 -2014 Class B PASS PASS N/A is an abbreviation for Not Applicable. Test mode: Mode 1 Lighting Record Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 7 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 2. GENERAL INFORMATION 2.1. Description of Device (EUT) EUT : Dixon outdoor 3 CCT Trade Mark : ARTIKA Additional Model No. : OUT-DIC-XXXXXX ("XXXXXX" can be A to Z and/or 0 to 9 and or/blank(commerical code) Model Declaration : PCB board, structure and internal of these model(s) are the same, So no additional models were tested Test Model : OUT-DIC-HD2BL Power Supply : Input: AC 120V, 60Hz, Max 11W Highest internal frequency (Fx) : Fx 108 MHz Highest internal frequency (Fx) Highest measured frequency Fx 108 MHz 1 GHz 108 MHz < Fx 500 MHz 2 GHz 500 MHz < Fx 1 GHz 5 GHz Fx > 1 GHz 5 × Fx up to a maximum of 6 GHz NOTE 1 For FM and TV broadcast receivers, Fx is determined from the highest frequency generated or used excluding the local oscillator and tuned frequencies. Where Fx is unknown, the radiated emission measurements shall be performed up to 6 GHz. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 8 of 18 FCC ID: 2AYFPOUT-DIC 2.2. Support Equipment List Manufacturer -- Description -- Model -- Report No.: LCS220429086AE Serial Number -- Certificate -- 2.3 External I/O Cable I/O Port Description -- Quantity -- Cable -- 2.4. Description of Test Facility Site Description EMC Lab. : NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 9 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 2.4. Statement of the Measurement Uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 4 "Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements" and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 2.5. Measurement Uncertainty Test Conducted Emission Radiated Emission Radiated Emission Radiated Emission Parameters Level accuracy (9kHz to 150kHz) (150kHz to 30MHz) Level accuracy (9kHz to 30MHz) Level accuracy (30MHz to 1000MHz) Level accuracy (above 1000MHz) Expanded Uncertainty (Ulab) 2.63 dB 2.35 dB 3.68 dB 3.48 dB 3.90 dB Expanded Uncertainty (Ucispr) 3.8 dB 3.4 dB N/A 5.3 dB 5.2 dB 1Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus. 2The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor of k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 10 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 3. TEST RESULTS 3.1. POWER LINE CONDUCTED EMISSION MEASUREMENT 3.1.1. Test Equipment The following test equipments are used during the power line conducted measurement: Item Test equipment 1 EMI Test Receiver 2 10dB Attenuator 3 Artificial Mains Network 4 EMI Test Software 5 Asymmetric Artificial Network 6 Voltage Probe 7 No. 2 shielded Room Manufacturer R&S SCHWARZBECK SCHWARZBECK EZ SCHWARZBECK SCHWARZBECK CHENGYU Model No. ESCI VTSD9561-F NSLK8127 EZ_EMC NTFM 8158 KT 9420 843 Serial No. Cal Date 101142 9561-F159 2021-06-08 2021-06-08 8127716 N/A 2021-06-08 / NTFM8158#120 2021-06-08 9420401 2021-06-08 / 2020-06-16 Due Date 2022-06-08 2022-06-08 2022-06-08 / 2022-06-08 2022-06-08 2023-06-16 3.1.2.Block Diagram of Test Setup 3.1.3.Test Standard Power Line Conducted Emission Limits (Class B) Frequency Limit (dBV) (MHz) Quasi-peak Level Average Level 0.15 ~ 0.50 66.0 ~ 56.0 * 56.0 ~ 46.0 * 0.50 ~ 5.00 56.0 46.0 5.00 ~ 30.00 60.0 50.0 NOTE1-The lower limit shall apply at the transition frequencies. NOTE2-The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.50MHz. 3.1.4.EUT Configuration on Test The following equipments are installed on Power Line Conducted Emission Measurement to meet the commission requirement and operating regulations in a manner, which tends to maximize its emission characteristics in a normal application. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 11 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 3.1.5.Operating Condition of EUT 3.1.5.1.Setup the EUT as shown on Section 3.1.2 3.1.5.2.Turn on the power of all equipments. 3.1.5.3.Let the EUT work in measuring Mode 1 and measure it. 3.1.6.Test Procedure The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This provides 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to FCC/ANSI C63.4-2014 on Conducted Emission Measurement. The bandwidth of the test receiver is set at 9kHz. The frequency range from 150kHz to 30MHz is investigated 3.1.7.Test Results PASS. The test result please refer to the next page. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 12 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE Test Model OUT-DIC-HD2BL Environmental Conditions 24.5, 55% RH Pol Line Test Mode Test Engineer Test Voltage Mode 1 Monkey Li AC 120V/60Hz Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 13 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE Test Model OUT-DIC-HD2BL Environmental Conditions 24.5, 55% RH Pol Neutral Test Mode Test Engineer Test Voltage Mode 1 Monkey Li AC 120V/60Hz Note: Pre-Scan all mode, Thus record worse case mode result in this report. Note: Measured = Reading Level + Correct Factor, Over = Measured - Limit Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 14 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 3.2. Radiated emission Measurement 3.2.1. Test Equipment The following test equipments are used during the radiated emission measurement: Item Test equipment Manufacturer Model No. Serial No. Cal Date Due Date 1 3m Semi Anechoic Chamber SIDT FRANKONIA SAC-3M 03CH03-HY 2021-06-15 2024-06-15 2 EMI Test Receiver R&S ESCI3 101010 2021-06-08 2022-06-08 3 Spectrum Analyzer Agilent N9020A MY49100699 2021-06-08 2022-06-08 4 Log-periodic Antenna SCHWARZBECK VULB9163 5094 2019-06-23 2022-06-23 5 Horn Antenna ETS-LINDGREN 3115 00034771 2019-06-23 2022-06-23 6 EMI Test Software EZ EZ_EMC N/A / / 7 Positioning Controller 8 EMI Test Software MF BK8807-4A-2T 2016-0808-008 / / AUDIX E3 / N/A N/A 3.2.2. Block Diagram of Test Setup Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 15 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE 3.2.3. Radiated Emission Limit (Class B) Limits for Radiated Disturbance Below 1GHz FREQUENCY DISTANCE FIELD STRENGTHS LIMIT MHz Meters V/m dB(V)/m 30 ~ 88 3 100 40 88 ~ 216 3 150 43.5 216 ~ 960 3 200 46 960 ~ 1000 3 500 54 Remark(1) Emission level (dB)V = 20 log Emission level V/m (2) The smaller limit shall apply at the cross point between two frequency bands. (3) Distance is the distance in meters between the measuring instrument, antenna and the closest point of any part of the device or system. Limits for Radiated Emission Above 1GHz Frequency Distance Peak Limit Average Limit (MHz) (Meters) (dBV/m) (dBV/m) Above 1000 3 74 54 ***Note: The lower limit applies at the transition frequency. 3.2.4. EUT Configuration on Measurement The following equipment are installed on Radiated Emission Measurement to meet the commission requirements and operating regulations in a manner which tends to maximize its emission characteristics in normal application. 3.2.5. Operating Condition of EUT 3.2.5.1.Setup the EUT as shown in Section 3.2.2. 3.2.5.2.Let the EUT work in test Mode 1 and measure it. 3.2.6. Test Procedure EUT and its simulators are placed on a turntable, which is 0.8 meter high above ground. The turntable can rotate 360 degrees to determine the position of the maximum emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted on a antenna tower. The antenna can be moved up and down between 1.0 meter and 4 meters to find out the maximum emission level. Broadband antenna (calibrated by-log antenna) is used as receiving antenna. Both horizontal and vertical polarization of the antenna is set on measurement. In order to find the maximum emission levels, all of the interface cables must be manipulated according to ANSI C63.4-2014 on radiated emission measurement. The bandwidth of the EMI test receiver is set at 120kHz, 300kHz. The frequency range from 30MHz to 1000MHz is checked. 3.2.7. Radiated Emission Noise Measurement Result PASS. The scanning waveforms please refer to the next page. Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 16 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE Test Model Environmental Conditions Pol Test Engineer OUT-DIC-HD2BL 23.3, 52% RH Vertical Monkey Li Test Mode Detector Function Distance Test Voltage Mode 1 Quasi-peak 3m AC 120V/60Hz Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 17 of 18 FCC ID: 2AYFPOUT-DIC Report No.: LCS220429086AE Test Model Environmental Conditions Pol Test Engineer OUT-DIC-HD2BL 23.3, 52% RH Horizontal Monkey Li Test Mode Detector Function Distance Test Voltage Mode 1 Quasi-peak 3m AC 120V/60Hz Note: 1. Pre-Scan all mode, Thus record worse case mode result in this report. Note: Measured = Reading Level + Correct Factor, Margin = Measured - Limit 4. TEST SETUP PHOTOGRAPHS OF EUT Please refer to separated files for Test Setup Photos of the EUT. 5. EXTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for External Photos of the EUT. 6. INTERIOR PHOTOGRAPHS OF THE EUT Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Page 18 of 18 FCC ID: 2AYFPOUT-DIC Please refer to separated files for Internal Photos of the EUT. Report No.: LCS220429086AE -----------------THE END OF TEST REPORT----------------- Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity
Related FCC IDs:
- 2AYFPOUT-DIC - ARTIKA FOR LIVING INC. Dixon outdoor 3 CCT [OUT-DIC]