MTi221212017-06E1-FCC-BT test report
Test reports
Hong Kong Etech Groups Ltd. EB5585 TWS Earbuds 2A3ZO-EB5585 2A3ZOEB5585 eb5585
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 60 Pages, 4.32MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6417982Test Report Report No.: MTi221212017-06E1 Date of issue: 2023-03-07 Applicant: Hong Kong Etech Groups Ltd. Product: Model(s): FCC ID: TWS Earbuds EB5585, EB5585-BKA, EB5585-BRP, EB5585-BRW, EBT4-21172 2A3ZO-EB5585 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 2 of 60 Report No.: MTi221212017-06E1 Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 3 of 60 Report No.: MTi221212017-06E1 Table of contents 1 General Description .......................................................................................................................... 5 1.1 Description of the EUT .......................................................................................................................................5 1.2 Description of test modes...................................................................................................................................5 1.3 Test conditions....................................................................................................................................................7 1.4 Description of support units................................................................................................................................7 2 Measurement uncertainty ................................................................................................................. 8 3 Summary of Test Result.................................................................................................................... 9 4 Test Laboratory................................................................................................................................ 10 5 Equipment List ................................................................................................................................ 11 6 Test Result ....................................................................................................................................... 12 6.1 Antenna requirement ........................................................................................................................................12 6.2 AC power line conducted emissions.................................................................................................................13 6.3 Radiated spurious emission .............................................................................................................................14 6.4 20dB emission bandwidth ................................................................................................................................27 6.5 Maximum conducted output power ..................................................................................................................28 6.6 Carrier frequency separation............................................................................................................................29 6.7 Time of occupancy............................................................................................................................................30 6.8 Number of hopping channels ...........................................................................................................................31 6.9 Band edge (Conducted) ...................................................................................................................................32 6.10 Conducted spurious emissions ......................................................................................................................33 Appendix A: 20dB Emission Bandwidth .............................................................................................. 34 Appendix B: Maximum conducted output power ................................................................................ 37 Appendix C: Carrier frequency separation .......................................................................................... 40 Appendix D: Time of occupancy ........................................................................................................... 42 Appendix E: Number of hopping channels .......................................................................................... 47 Appendix F: Band edge measurements ............................................................................................... 49 Appendix G: Conducted Spurious Emission ....................................................................................... 52 Photographs of the Test Setup.............................................................................................................. 59 Photographs of the EUT ........................................................................................................................ 60 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Applicant: Address: Manufacturer: Address: Product description Product name: Trademark: Model name: Serial Model: Standards: Test method: Date of Test Date of test: Test result: Page 4 of 60 Report No.: MTi221212017-06E1 Hong Kong Etech Groups Ltd. 16/F, Block C, 2nd Phase of Central Avenue, Haihong Industrial Area, Xixiang, Baoan, Shenzhen, China Hong Kong Etech Groups Ltd. 16/F, Block C, 2nd Phase of Central Avenue, Haihong Industrial Area, Xixiang, Baoan, Shenzhen, China TWS Earbuds N/A EB5585 EB5585-BKA, EB5585-BRP, EB5585-BRW, EBT4-21172 FCC 47 CFR Part 15 Subpart C ANSI C63.10-2013 2022-12-27 ~ 2023-03-07 Pass Test Engineer : Reviewed By: : Approved By: : (David Lee) (Leon Chen) (Tom Xue) Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 5 of 60 Report No.: MTi221212017-06E1 1 General Description 1.1 Description of the EUT Product name: TWS Earbuds Model name: EB5585 Series Model: Model difference: Electrical rating: Hardware version: EB5585-BKA, EB5585-BRP, EB5585-BRW, EBT4-21172 All the models are the same circuit and module, except the model name and color. Input: DC 5V/0.3A Battery: Bluetooth earphone: DC 3.7V 30mAh V1.0 Software version: V161 Accessories: Cable: USB-A to USB-C cable 0.3m Test sample(s) number: MTi221212017-06S1001 RF specification: Bluetooth version: V5.1 Operation frequency: 2402 MHz ~ 2480 MHz Modulation type: Antenna(s) information: Maximum conducted output power: GFSK, /4-DQPSK Antenna type: Ceramic Chip antenna Antenna gain: 2.67 dBi -0.14 dBm 1.2 Description of test modes 1.2.1 Operation channel list Channel 0 1 2 3 4 5 6 7 8 9 10 11 Frequency (MHz) 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 Channel 20 21 22 23 24 25 26 27 28 29 30 31 Frequency (MHz) 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 Channel 40 41 42 43 44 45 46 47 48 49 50 51 Frequency (MHz) 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 Channel 60 61 62 63 64 65 66 67 68 69 70 71 Frequency (MHz) 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 6 of 60 Report No.: MTi221212017-06E1 Channel 12 13 14 15 16 17 18 19 Frequency (MHz) 2414 2415 2416 2417 2418 2419 2420 2421 Channel 32 33 34 35 36 37 38 39 Frequency (MHz) 2434 2435 2436 2437 2438 2439 2440 2441 Channel 52 53 54 55 56 57 58 59 Frequency (MHz) 2454 2455 2456 2457 2458 2459 2460 2461 Channel 72 73 74 75 76 77 78 - Frequency (MHz) 2474 2475 2476 2477 2478 2479 2480 - Note: The test software provided by manufacturer is used to control EUT for working in engineering mode, that enables selectable channel, and capable of continuous transmitting mode. Mode GFSK /4-DQPSK Test Software Channel Power setting 2402MHz 10 10 FCC_assist_1.0.2.2 2441MHz 10 10 2480MHz 10 10 The test software: Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 7 of 60 1.3 Test conditions Environment of test site: Temperature: Humidity: 15ºC~35ºC 20 % RH ~ 75 % RH 1.4 Description of support units Support equipment list Description / Support cable list Description / Model / Length (m) / Serial No. / From / Report No.: MTi221212017-06E1 Manufacturer / To / Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 8 of 60 Report No.: MTi221212017-06E1 2 Measurement uncertainty Parameter AC power line conducted emission (9 kHz~30 MHz) Occupied Bandwidth Conducted RF output power Conducted spurious emissions Radiated emission (9 kHz ~ 30 MHz) Radiated emission (30 MHz~1 GHz) Radiated emission (above 1 GHz) Measurement uncertainty ±2.5 dB ±3 % ±0.16 dB ±0.21 dB ±4.0 dB ±4.2 dB ±4.3 dB Note: the measurement uncertainty is calculated and correspond to a factor k = 2 (which provide confidence levels of 95.45 %) Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 9 of 60 Report No.: MTi221212017-06E1 3 Summary of Test Result No. FCC reference 1 § 15.203 2 § 15.207 3 § 15.247(d), 15.209, 15.205 4 § 15.247(a)(1) 5 § 15.247(b)(1) 6 § 15.247(a)(1) 7 § 15.247(a)(1) 8 § 15.247(a)(1) 9 § 15.247(d) 10 § 15.247(d) Description of test Antenna requirement AC power line conducted emissions Radiated spurious emissions 20dB emission bandwidth Maximum conducted output power Carrier Frequencies Separation Time of occupancy Number of hopping channels Band edge (Conducted) Conducted spurious emissions Result Pass N/A Pass Pass Pass Pass Pass Pass Pass Pass Notes: N/A means not applicable. Since the EUT cannot be operating while charging, therefore AC power line conducted emissions test is not required. Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 10 of 60 Report No.: MTi221212017-06E1 4 Test Laboratory Test laboratory: Test site location: Telephone: Shenzhen Microtest Co., Ltd. 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China (86-755)88850135 Fax: (86-755)88850136 CNAS Registration No.: CNAS L5868 FCC Registration No.: 448573 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 11 of 60 Report No.: MTi221212017-06E1 5 Equipment List No. Equipment Manufacturer Model Serial No. Cal. date Cal. Due MTi-E002 EMI Test Receiver MTi-E023 Artificial power network MTi-E025 Artificial power network R&S Schwarzbeck Schwarzbeck ESCI3 NSLK8127 NSLK8127 101368 2022/05/05 2023/05/04 NSLK8127# 841 2022/05/05 2023/05/04 8127183 2022/05/05 2023/05/04 MTI-E043 EMI test receiver R&S ESCI7 101166 2022/05/05 2023/05/04 MTI-E046 Active Loop Antenna Schwarzbeck FMZB 1519 B 00044 2021/05/30 2023/05/29 MTI-E044 Broadband antenna Schwarzbeck VULB9163 9163-1338 2021/05/30 2023/05/29 MTI-E045 Horn antenna Schwarzbeck BBHA9120D 9120D-2278 2021/05/30 2023/05/29 MTI-E047 Pre-amplifier Hewlett-Packard 8447F 3113A06184 2022/05/05 2023/05/04 MTI-E048 Pre-amplifier Agilent 8449B 3008A01120 2022/05/05 2023/05/04 MTi-E120 Broadband antenna Schwarzbeck VULB9163 9163-1419 2021/05/30 2023/05/29 MTi-E121 Pre-amplifier Hewlett-Packard 8447D 2944A09365 2022/04/15 2023/04/14 MTi-E123 Pre-amplifier Agilent 8449B 3008A04723 2022/05/05 2023/05/04 MTi-E135 Horn antenna MTi-E136 Pre-amplifier MTi-E062 PXA Signal Analyzer Schwarzbeck Space-Dtronics Agilent BBHA 9170 00987 2021/05/30 2023/05/29 EWLAN1840G -G45 210405001 2022/05/05 2023/05/04 N9030A MY51350296 2022/05/05 2023/05/04 MTi-E067 RF Control Unit Tonscend JS0806-1 19D8060152 2022/05/05 2023/05/04 MTi-E068 MTi-E069 MTI-E010S MTI-E014S RF Control Unit Band Reject Filter Group EMI Measurement Software RF Test System Tonscend Tonscend Farad Tonscend JS0806-2 19D8060153 2022/05/05 2023/05/04 JS0806-F 19D8060160 2022/05/05 2023/05/04 EZ-EMC Ver. EMEC-3A1 / TS®JS1120 V2.6.88.0330 / / / / / Note: the calibration interval of the test equipment is 12 or 24 months and the calibrations are traceable to international system unit(SI) Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 12 of 60 Report No.: MTi221212017-06E1 6 Test Result 6.1 Antenna requirement § 15.203 requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of §§15.211, 15.213, 15.217, 15.219, 15.221, or §15.236. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with §15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Description of the antenna of EUT The antenna of the EUT is permanently attached. Conclusion: The EUT complies with the requirement of § 15.203. Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 13 of 60 Report No.: MTi221212017-06E1 6.2 AC power line conducted emissions 6.2.1 Limits Frequency (MHz) 0.15 -0.5 Detector type / Bandwidth Limit-Quasi-peak dBV 66 to 56 Limit-Average dBV 56 to 46 0.5 -5 Average / 9 kHz 56 46 5 -30 60 50 Note 1: the limit decreases with the logarithm of the frequency in the range of 0.15 MHz to 0.5 MHz. 6.2.2 Test Procedures a) Test method: ANSI C63.10-2013 Section 6.2. b) The EUT is connected to the main power through a line impedance stabilization network (LISN). All support equipment is powered from additional LISN(s). c) Emissions were measured on each current carrying line of the EUT using an EMI test receiver connected to the LISN powering the EUT. d) The test receiver scanned from 150 kHz to 30 MHz for emissions in each of the test modes described in Item 1.2. e) The test data of the worst-case condition(s) was recorded. 6.2.3 Test setup Vertical Ground Reference Plane Test Receiver 40 cm EUT & Support Units LISN 80 cm Horizontal Ground Reference Plane For the actual test configuration, please refer to the related item Photographs of the test setup. 6.2.4 Test Result Notes: Since the EUT cannot be operating while charging, therefore AC power line conducted emissions test is not required. Calculation formula: Measurement (dBV) = Reading Level (dBV) + Correct Factor (dB) Over (dB) = Measurement (dBV) Limit (dBV) Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 14 of 60 Report No.: MTi221212017-06E1 6.3 Radiated spurious emission 6.3.1 Limits § 15.247 (d) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in § 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in § 15.205(a), must also comply with the radiated emission limits specified in § 15.209(a) (see § 15.205(c)). § 15.209 Radiated emission limits; general requirements. Frequency (MHz) 0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Field strength (microvolts/meter) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 Measurement distance (meters) 300 30 30 3 3 3 Above 960 500 3 Note 1: the tighter limit applies at the band edges. Note 2: the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector § 15.35 (b) requirements: When average radiated emission measurements are specified in this part, including average emission measurements below 1000 MHz, there also is a limit on the peak level of the radio frequency emissions. Unless otherwise specified, e.g., see §§ 15.250, 15.252, 15.253(d), 15.255, 15.256, and 15.509 through 15.519, the limit on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit applicable to the equipment under test. Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 15 of 60 Report No.: MTi221212017-06E1 According to ANSI C63.10-2013, the tests shall be performed in the frequency range shown in the following table: Frequency range of measurements for unlicensed wireless device Lowest frequency generated in the device 9 kHz to below 10 GHz At or above 10 GHz to below 30 GHz At or above 30 GHz Upper frequency range of measurement 10th harmonic of highest fundamental frequency or to 40 GHz, whichever is lower 5th harmonic of highest fundamental frequency or to 100 GHz, whichever is lower 5th harmonic of highest fundamental frequency or to 200 GHz, whichever is lower, unless otherwise specified Frequency range of measurements for unlicensed wireless device with digital device Highest frequency generated or used in the device or on which the device operates or tunes Upper frequency range of measurement Below 1.705 MHz 30 MHz 1.705 MHz to 108 MHz 1000 MHz 108 MHz to 500 MHz 2000 MHz 500 MHz to 1000 MHz Above 1000 MHz 5000 MHz 5th harmonic of the highest frequency or 40 GHz, whichever is lower Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 6.3.2 Test setup Below 30MHz EUT& Support Units 80cm 30MHz~1GHz Page 16 of 60 3m Turn Table Ground Plan Test Receiver Report No.: MTi221212017-06E1 Above 1GHz For the actual test configuration, please refer to the related item Photographs of the test setup. Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 17 of 60 Report No.: MTi221212017-06E1 6.3.3 Test procedure a) Test method: ANSI C63.10-2013 Section 6.3, 6.4, 6.5, 6.6, 6.10. b) The EUT is placed on an on-conducting table 0.8 meters above the ground plane for measurement below 1GHz, 1.5 meters above the ground plane for measurement above 1GHz. c) Emission blew 18 GHz were measured at a 3 meters test distance, above 18 GHz were measured at 1-meter test distance with the application of a distance correction factor d) The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. KDB 558074 D01 15.247 Meas Guidance v05r02 The use of a duty cycle correction factor (DCCF) is permitted for calculating average radiated field strength emission levels for an FHSS device in 15.247. This DCCF can be applied when the unwanted emission limit is subject to an average field strength limit (e.g., within a Government Restricted band) and the conditions specified in Section 15.35(c) can be satisfied. The average radiated field strength is calculated by subtracting the DCCF from the maximum radiated field strength level as determined through measurement. The maximum radiated field strength level represents the worst-case (maximum amplitude) RMS measurement of the emission(s) during continuous transmission (i.e., not including any time intervals during which the transmitter is off or is transmitting at a reduced power level). It is also acceptable to apply the DCCF to a measurement performed with a peak detector instead of the specified RMS power averaging detector. Note that Section 15.35(c) specifies that the DCCF shall represent the worst-case (greatest duty cycle) over any 100 msec transmission period. Test instrument setup Frequency Test receiver / Spectrum analyzer setting 9 kHz ~ 150 kHz Quasi Peak / RBW: 200 Hz 150 kHz ~ 30 MHz Quasi Peak / RBW: 9 kHz 30 MHz ~ 1 GHz Above 1 GHz Quasi Peak / RBW: 120 kHz Peak / RBW: 1 MHz, VBW: 3MHz, Peak detector AVG / RBW: 1 MHz, VBW: 1/T, Peak detector 6.3.4 Test results Notes: The amplitude of spurious emissions which are attenuated more than 20 dB below the limits are not reported. All modes of operation of the EUT were investigated, and only the worst-case results are reported. There were no emissions found below 30MHz within 20dB of the limit. Calculation formula: Measurement (dBV/m) = Reading Level (dBV) + Correct Factor (dB/m) Over (dB) = Measurement (dBV/m) Limit (dBV/m) Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 18 of 60 Left Earphone: Radiated emissions between 30MHz 1GHz Test mode: Power supply: TX 2DH5-2480 DC 3.7V Polarization: Test site: Report No.: MTi221212017-06E1 Horizontal RE chamber 2 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 19 of 60 Radiated emissions between 30MHz 1GHz Test mode: Power supply: TX 2DH5-2480 DC 3.7V Polarization: Test site: Report No.: MTi221212017-06E1 Vertical RE chamber 2 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 20 of 60 Right Earphone: Radiated emissions between 30MHz 1GHz Test mode: Power supply: TX 2DH5-2480 DC 3.7V Polarization: Test site: Report No.: MTi221212017-06E1 Horizontal RE chamber 2 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 21 of 60 Radiated emissions between 30MHz 1GHz Test mode: Power supply: TX 2DH5-2480 DC 3.7V Polarization: Test site: Report No.: MTi221212017-06E1 Vertical RE chamber 2 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 22 of 60 Report No.: MTi221212017-06E1 Left Earphone: Radiated emissions 1 GHz ~ 25 GHz Frequency (MHz) Reading Level (dBV) 4804 4804 7206 7206 9608 9608 4804 4804 7206 7206 9608 9608 47.39 43.31 41.09 35.05 46.35 42.87 47.32 43.48 40.62 34.13 44.00 39.87 4882 4882 7323 7323 9764 9764 4882 4882 7323 7323 9764 9764 40.88 34.68 40.65 34.23 44.30 40.42 47.92 43.10 41.04 34.63 42.80 38.70 Correct Factor (dB/m) Measuremen t (dBV/m) Limits (dBV/m) GFSK - 2402 MHz TX mode 0.74 48.13 74.00 0.74 44.05 54.00 6.02 47.11 74.00 6.02 41.07 54.00 5.88 52.23 74.00 5.88 48.75 54.00 0.74 48.06 74.00 0.74 44.22 54.00 6.02 46.64 74.00 6.02 40.15 54.00 5.88 49.88 74.00 5.88 45.75 54.00 GFSK - 2441 MHz TX mode 1.05 41.93 74.00 1.05 35.73 54.00 5.94 46.59 74.00 5.94 40.17 54.00 6.55 50.85 74.00 6.55 46.97 54.00 1.05 48.97 74.00 1.05 44.15 54.00 5.94 46.98 74.00 5.94 40.57 54.00 6.55 49.35 74.00 6.55 45.25 54.00 Over (dB) -25.87 -9.95 -26.89 -12.93 -21.77 -5.25 -25.94 -9.78 -27.36 -13.85 -24.12 -8.25 -32.07 -18.27 -27.41 -13.83 -23.15 -7.03 -25.03 -9.85 -27.02 -13.43 -24.65 -8.75 Detector Peak/AVG Polarization H/V Peak V AVG V Peak V AVG V Peak V AVG V Peak H AVG H Peak H AVG H Peak H AVG H Peak V AVG V Peak V AVG V Peak V AVG V Peak H AVG H Peak H AVG H Peak H AVG H Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Frequency (MHz) Reading Level (dBV) 4960 4960 7440 7440 9920 9920 4960 4960 7440 7440 9920 9920 41.37 35.37 40.12 33.86 48.81 42.03 47.71 43.55 39.74 33.67 49.97 45.96 Page 23 of 60 Report No.: MTi221212017-06E1 Correct Factor (dB/m) Measuremen t (dBV/m) Limits (dBV/m) GFSK - 2480 MHz TX mode 1.50 42.87 74.00 1.50 36.87 54.00 5.61 45.73 74.00 5.61 39.47 54.00 6.10 54.91 74.00 6.10 48.13 54.00 1.50 49.21 74.00 1.50 45.05 54.00 5.61 45.35 74.00 5.61 39.28 54.00 6.10 56.07 74.00 6.10 52.06 54.00 Over (dB) -31.13 -17.13 -28.27 -14.53 -19.09 -5.87 -24.79 -8.95 -28.65 -14.72 -17.93 -1.94 Detector Peak/AVG Polarization H/V Peak V AVG V Peak V AVG V Peak V AVG V Peak H AVG H Peak H AVG H Peak H AVG H Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 24 of 60 Report No.: MTi221212017-06E1 Light Earphone: Radiated emissions 1 GHz ~ 25 GHz Frequency (MHz) Reading Level (dBV) 4804 4804 7206 7206 9608 9608 4804 4804 7206 7206 9608 9608 45.38 39.29 40.33 34.09 40.47 34.31 55.30 46.15 40.99 34.98 42.02 35.58 4882 4882 7323 7323 9764 9764 4882 4882 7323 7323 9764 9764 46.20 40.15 40.15 34.06 40.97 36.70 54.94 50.36 41.28 35.08 44.50 40.43 Correct Factor (dB/m) Measuremen t (dBV/m) Limits (dBV/m) GFSK - 2402 MHz TX mode 0.74 46.12 74.00 0.74 40.03 54.00 6.02 46.35 74.00 6.02 40.11 54.00 5.88 46.35 74.00 5.88 40.19 54.00 0.74 56.04 74.00 0.74 46.89 54.00 6.02 47.01 74.00 6.02 41.00 54.00 5.88 47.90 74.00 5.88 41.46 54.00 GFSK - 2441 MHz TX mode 1.05 47.25 74.00 1.05 41.20 54.00 5.94 46.09 74.00 5.94 40.00 54.00 6.55 47.52 74.00 6.55 43.25 54.00 1.05 55.99 74.00 1.05 51.41 54.00 5.94 47.22 74.00 5.94 41.02 54.00 6.55 51.05 74.00 6.55 46.98 54.00 Over (dB) -27.88 -13.97 -27.65 -13.89 -27.65 -13.81 -17.96 -7.11 -26.99 -13.00 -26.10 -12.54 -26.75 -12.80 -27.91 -14.00 -26.48 -10.75 -18.01 -2.59 -26.78 -12.98 -22.95 -7.02 Detector Peak/AVG Polarization H/V Peak V AVG V Peak V AVG V Peak V AVG V Peak H AVG H Peak H AVG H Peak H AVG H Peak V AVG V Peak V AVG V Peak V AVG V Peak H AVG H Peak H AVG H Peak H AVG H Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Frequency (MHz) Reading Level (dBV) 4960 4960 7440 7440 9920 9920 4960 4960 7440 7440 9920 9920 46.45 42.08 40.17 34.00 46.78 42.66 52.80 49.23 40.26 33.91 47.07 44.07 Page 25 of 60 Report No.: MTi221212017-06E1 Correct Factor (dB/m) Measuremen t (dBV/m) Limits (dBV/m) GFSK - 2480 MHz TX mode 1.50 47.95 74.00 1.50 43.58 54.00 5.61 45.78 74.00 5.61 39.61 54.00 6.10 52.88 74.00 6.10 48.76 54.00 1.50 54.30 74.00 1.50 50.73 54.00 5.61 45.87 74.00 5.61 39.52 54.00 6.10 53.17 74.00 6.10 50.17 54.00 Over (dB) -26.05 -10.42 -28.22 -14.39 -21.12 -5.24 -19.70 -3.27 -28.13 -14.48 -20.83 -3.83 Detector Peak/AVG Polarization H/V Peak V AVG V Peak V AVG V Peak V AVG V Peak H AVG H Peak H AVG H Peak H AVG H Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Radiated emissions at band edge Frequency (MHz) Reading Level (dBV) Correct Factor (dB/m) (MHz) 2310 2310 2390 2390 2310 2310 2390 2390 (dBV) 46.96 37.41 48.40 37.58 47.63 37.38 47.40 37.86 (dB/m) -8.08 -8.08 -7.71 -7.71 -8.08 -8.08 -7.71 -7.71 2483.5 2483.5 2500 2500 2483.5 2483.5 2500 2500 46.40 37.80 48.02 37.81 48.51 39.12 47.50 38.00 -7.24 -7.24 -7.17 -7.17 -7.24 -7.24 -7.17 -7.17 Page 26 of 60 Measurement Limits (dBV/m) (dBV/m) GFSK Low band-edge (dBV/m) (dBV/m) 38.88 74.00 29.33 54.00 40.69 74.00 29.87 54.00 39.55 74.00 29.30 54.00 39.69 74.00 30.15 54.00 GFSK High band-edge 39.16 74.00 30.56 54.00 40.85 74.00 30.64 54.00 41.27 74.00 31.88 54.00 40.33 74.00 30.83 54.00 Report No.: MTi221212017-06E1 Over (dB) Detector Peak/AVG Polarization H/V (dB) Peak/AVG H/V -35.12 Peak V -24.67 AVG V -33.31 Peak V -24.13 AVG V -34.45 Peak H -24.70 AVG H -34.31 Peak H -23.85 AVG H -34.84 Peak V -23.44 AVG V -33.15 Peak V -23.36 AVG V -32.73 Peak H -22.12 AVG H -33.67 Peak H -23.17 AVG H Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 6.4 20dB emission bandwidth 6.4.1 Limits None, for reporting purposes only. 6.4.2 Test setup EUT Page 27 of 60 6.4.3 Test procedures Test method: ANSI C63.10-2013 Section 6.9.2 6.4.4 Test results Note: See the Appendix A Report No.: MTi221212017-06E1 Spectrum Analyzer Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 28 of 60 Report No.: MTi221212017-06E1 6.5 Maximum conducted output power 6.5.1 Limits For frequency hopping systems operating in the 2400-2483.5 MHz band employing at least 75 non-overlapping hopping channels, and all frequency hopping systems in the 5725-5850 MHz band: 1 watt. For all other frequency hopping systems in the 2400-2483.5 MHz band: 0.125 watts. 6.5.2 Test setup EUT 6.5.3 Test procedure Test method: ANSI C63.10-2013 Section 7.8.5 6.5.4 Test results Note: see the Appendix B Spectrum Analyzer Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 29 of 60 Report No.: MTi221212017-06E1 6.6 Carrier frequency separation 6.6.1 Limits Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater. Alternatively, frequency hopping systems operating in the 2400-2483.5 MHz band may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater 6.6.2 Test setup EUT Spectrum Analyzer 6.6.3 Test procedure Test method: ANSI C63.10-2013 Section 7.8.2 6.6.4 Test results Note: see the Appendix C Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 30 of 60 Report No.: MTi221212017-06E1 6.7 Time of occupancy 6.7.1 Limits The average time of occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied by the number of hopping channels employed. 6.7.2 Test setup EUT Spectrum Analyzer 6.7.3 Test procedure Test method: ANSI C63.10-2013 Section 7.8.4 6.7.4 Test results Note: see the Appendix D Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 31 of 60 Report No.: MTi221212017-06E1 6.8 Number of hopping channels 6.8.1 Limit Frequency hopping systems in the 2400-2483.5MHz band shall use at least 15 channels. 6.8.2 Test setup EUT Spectrum Analyzer 6.8.3 Test procedure Test method: ANSI C63.10-2013 Section 7.8.3 6.8.4 Test results Note: see the Appendix E Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 32 of 60 Report No.: MTi221212017-06E1 6.9 Band edge (Conducted) 6.9.1 Limits In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). 6.9.2 Test setup EUT Spectrum Analyzer 6.9.3 Test procedure Test method: ANSI C63.10-2013 Section 6.10.4 6.9.4 Test results Note: see the Appendix F Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 33 of 60 Report No.: MTi221212017-06E1 6.10 Conducted spurious emissions 6.10.1 Limits In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). 6.10.2 Test setup EUT Spectrum Analyzer 6.10.3 Test procedure Test method: ANSI C63.10-2013 Section 7.8.8 6.10.4 Test results Note: See the Appendix G Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 34 of 60 APPENDIX A: 20DB EMISSION BANDWIDTH Test Result Test Mode DH5 2DH5 Antenna Ant1 Ant1 Frequency [MHz] 2402 2441 2480 2402 2441 2480 Report No.: MTi221212017-06E1 20db EBW [MHz] 0.951 0.954 0.945 1.290 1.284 1.281 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs Page 35 of 60 DH5_Ant1_2402 Report No.: MTi221212017-06E1 DH5_Ant1_2441 DH5_Ant1_2480 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 36 of 60 2DH5_Ant1_2402 Report No.: MTi221212017-06E1 2DH5_Ant1_2441 2DH5_Ant1_2480 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 37 of 60 Report No.: MTi221212017-06E1 APPENDIX B: MAXIMUM CONDUCTED OUTPUT POWER Test Result Peak Test Mode DH5 2DH5 Antenna Ant1 Ant1 Frequency [MHz] 2402 2441 2480 2402 2441 2480 Conducted Peak Power [dBm] -0.97 -2.16 -1.94 -0.14 -1.32 -1.10 Limit [dBm] 30 30 30 20.97 20.97 20.97 Verdict PASS PASS PASS PASS PASS PASS Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs Page 38 of 60 DH5_Ant1_2402 Report No.: MTi221212017-06E1 DH5_Ant1_2441 DH5_Ant1_2480 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 39 of 60 2DH5_Ant1_2402 Report No.: MTi221212017-06E1 2DH5_Ant1_2441 2DH5_Ant1_2480 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 40 of 60 Report No.: MTi221212017-06E1 APPENDIX C: CARRIER FREQUENCY SEPARATION Test Result Test Mode DH5 2DH5 Antenna Ant1 Ant1 Frequency [MHz] Hop Hop Result [MHz] 1 0.998 Limit [MHz] 0.954 0.860 Verdict PASS PASS Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs Page 41 of 60 DH5_Ant1_Hop Report No.: MTi221212017-06E1 2DH5_Ant1_Hop Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 42 of 60 APPENDIX D: TIME OF OCCUPANCY Test Result Test Mode DH1 DH3 DH5 2DH1 2DH3 2DH5 Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Frequency [MHz] Hop Hop Hop Hop Hop Hop BurstWidth [ms] 0.381 1.637 2.885 0.390 1.643 2.891 Hops in 3.16s [Num] 32 18 10 32 15 12 Notes: 1. Period time = 0.4s * 79 = 31.6s 2. Result (Time of occupancy) = BurstWidth[ms] * Hops in 3.16s [Num] * 10 Report No.: MTi221212017-06E1 Result [s] 0.122 0.295 0.289 0.125 0.247 0.347 Limit [s] 0.4 0.4 0.4 0.4 0.4 0.4 Verdict PASS PASS PASS PASS PASS PASS Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs Page 43 of 60 DH1_Ant1_Hop Report No.: MTi221212017-06E1 DH3_Ant1_Hop Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 44 of 60 Report No.: MTi221212017-06E1 DH5_Ant1_Hop Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 45 of 60 2DH1_Ant1_Hop Report No.: MTi221212017-06E1 2DH3_Ant1_Hop Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 46 of 60 Report No.: MTi221212017-06E1 2DH5_Ant1_Hop Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 47 of 60 APPENDIX E: NUMBER OF HOPPING CHANNELS Test Result Test Mode DH5 2DH5 Antenna Ant1 Ant1 Frequency [MHz] Hop Hop Result [Num] 79 79 Report No.: MTi221212017-06E1 Limit [Num] 15 15 Verdict PASS PASS Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs Page 48 of 60 DH5_Ant1_Hop Report No.: MTi221212017-06E1 2DH5_Ant1_Hop Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 49 of 60 APPENDIX F: BAND EDGE MEASUREMENTS Test Graphs DH5_Ant1_Low_2402 Report No.: MTi221212017-06E1 DH5_Ant1_High_2480 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 50 of 60 DH5_Ant1_Low_Hop_2402 Report No.: MTi221212017-06E1 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 51 of 60 2DH5_Ant1_High_2480 Report No.: MTi221212017-06E1 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 52 of 60 APPENDIX G: CONDUCTED SPURIOUS EMISSION Test Graphs DH5_Ant1_2402_0~Reference Report No.: MTi221212017-06E1 DH5_Ant1_2402_30~1000 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 53 of 60 DH5_Ant1_2402_1000~26500 Report No.: MTi221212017-06E1 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 54 of 60 DH5_Ant1_2441_1000~26500 Report No.: MTi221212017-06E1 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 55 of 60 DH5_Ant1_2480_1000~26500 Report No.: MTi221212017-06E1 2DH5_Ant1_2402_0~Reference 2DH5_Ant1_2402_30~1000 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 56 of 60 2DH5_Ant1_2402_1000~26500 Report No.: MTi221212017-06E1 2DH5_Ant1_2441_0~Reference 2DH5_Ant1_2441_30~1000 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 57 of 60 2DH5_Ant1_2441_1000~26500 Report No.: MTi221212017-06E1 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 58 of 60 2DH5_Ant1_2480_1000~26500 Report No.: MTi221212017-06E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 59 of 60 Photographs of the Test Setup See the Appendix Test Setup Photos. Report No.: MTi221212017-06E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Photographs of the EUT See the Appendix - EUT Photos. Page 60 of 60 ----End of Report---- Report No.: MTi221212017-06E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected]
Related FCC IDs:
- 2A3ZO-EB5585 - Hong Kong Etech Groups Ltd. TWS Earbuds [-EB5585] Acrobat Distiller 18.0 (Windows)