FCC & IC Certification Report
Rick McMurray
EMC Co-located Test Results Rev 0.1
HARRIS CORPORATION TR-0145-E XL-200P, Multi-Band Portable Land Mobile Radio, Non-Rebanded OWDTR-0145-E OWDTR0145E tr 0145 e
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 24 Pages, 318.79KB
Document DEVICE REPORTGetApplicationAttachment.html?id=4423040Engineering Solutions & Electromagnetic Compatibility Services Class 2 Permissive Change Harris Corporation 221 Jefferson Ridge Parkway Lynchburg, VA 24501 Model: XL-200P (International) FCC ID: OWDTR-0145-E IC: 3636B-0145 August 21, 2019 Standards Referenced for this Report Part 2: 2018 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 15B: 2018 Radio Frequency Devices Part 22: 2018 Part 74: 2018 Part 80: 2018 Public Mobile Services Experimental Radio, Auxiliary, Special Broadcast And Other Program Distributional Services Stations In The Maritime Services Part 90: 2018 Private Land Portable Radio Services ANSI C63.26-2017 American National Standard for Compliance Testing of Transmitters Used in Licensed Radio Services RSS-119 Issue 12 Land Mobile and Fixed Radio Transmitters and Receivers 27.41 to 960.0 MHz ICES-003 Issue 6 Information Technology Equipment (Including Digital Apparatus) -- Limits and Methods of Measurement Report Prepared By: Daniel W. Baltzell Document Number: 2019070 This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc. and Harris Corporation. Test results relate only to the item tested. This replaces R0.0. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANAB. Refer to certificate and scope of accreditation AT-1445. 360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170 Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Table of Contents Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 1 General Information....................................................................................................................................5 1.1 Test Facility...........................................................................................................................................5 1.2 Related Submittal(s)/Grant(s) ................................................................................................................5 2 Tested System Details................................................................................................................................5 2.1 EUT Exercise Description .....................................................................................................................7 2.2 Test Result Summary............................................................................................................................7 3 FCC Part 2.1053(a): Field Strength of Spurious Radiation; Part 90.543: Out of Band Emissions Limit; RSSGen 6.13: Transmitter Unwanted Emissions .....................................................................................................8 3.1 Test Procedure .....................................................................................................................................8 3.2 Test Data ..............................................................................................................................................8 4 Conclusion ..........................................................................................................................................24 Page 2 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Table of Figures Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Figure 2-1: Configuration of Tested System ..............................................................................................6 Table 2-1: Table 2-2: Table 2-3: Table 3-1: Table 3-2: Table 3-3: Table 3-4: Table 3-5: Table 3-6: Table 3-7: Table 3-8: Table 3-9: Table 3-10: Table 3-11: Table 3-12: Table 3-13: Table 3-14: Table 3-15: Table 3-16: Table 3-17: Table 3-18: Table 3-19: Table 3-20: Table 3-21: Table 3-22: Table 3-23: Table 3-24: Table 3-25: Table 3-26: Table 3-27: Table 3-28: Table 3-29: Table 3-30: Table 3-31: Table of Tables Equipment Under Test (EUT) ..................................................................................................5 Auxiliary Equipment ................................................................................................................6 Test Result Summary FCC Part 15 Subpart C......................................................................7 Field Strength of Spurious Radiation 136.000 MHz...............................................................8 Field Strength of Spurious Radiation 138.000 MHz...............................................................9 Field Strength of Spurious Radiation 141.000 MHz...............................................................9 Field Strength of Spurious Radiation 144.000 MHz.............................................................10 Field Strength of Spurious Radiation 148.000 MHz.............................................................10 Field Strength of Spurious Radiation 150.000 MHz.............................................................11 Field Strength of Spurious Radiation 156.800 MHz.............................................................11 Field Strength of Spurious Radiation 162.000 MHz.............................................................12 Field Strength of Spurious Radiation 174.000 MHz.............................................................12 Field Strength of Spurious Radiation 406.1000 MHz...........................................................13 Field Strength of Spurious Radiation 418.0125 MHz...........................................................13 Field Strength of Spurious Radiation 429.9875 MHz...........................................................14 Field Strength of Spurious Radiation 450.0125 MHz...........................................................14 Field Strength of Spurious Radiation 459.9750 MHz...........................................................15 Field Strength of Spurious Radiation 469.9875 MHz...........................................................15 Field Strength of Spurious Radiation 768.0125 MHz...........................................................16 Field Strength of Spurious Radiation 771.0125 MHz...........................................................16 Field Strength of Spurious Radiation 775.9875 MHz...........................................................17 Field Strength of Spurious Radiation 798.0125 MHz...........................................................17 Field Strength of Spurious Radiation 801.0125 MHz...........................................................18 Field Strength of Spurious Radiation 805.9875 MHz...........................................................18 Field Strength of Spurious Radiation 806.0250 MHz...........................................................19 Field Strength of Spurious Radiation 809.0000 MHz...........................................................19 Field Strength of Spurious Radiation 815.9875 MHz...........................................................20 Field Strength of Spurious Radiation 851.0250 MHz...........................................................20 Field Strength of Spurious Radiation 856.0250 MHz...........................................................21 Field Strength of Spurious Radiation 860.9875 MHz...........................................................21 Part 90.543(f): Out of Band Emissions Limit .........................................................................22 FCC Unintentional Digital/RX Emissions ...............................................................................22 Collocation Frequencies Tested ............................................................................................23 Test Equipment Used For Testing Field Strength of Spurious Radiation and Unintentional Emissions .............................................................................................................................23 Appendix A: Table of Appendixes Test Configuration Photographs............................................................................................25 Page 3 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Table of Photographs Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Photograph 1: Photograph 2: Photograph 3: Photograph 4: Radiated Emissions (Spurious/Harmonics) Over 1 GHz, Front View......................................25 Radiated Emissions (Spurious/Harmonics) Over 1 GHz, Back View ......................................26 Radiated Emissions (Spurious/Harmonics) Under 1 GHz, Front View ....................................27 Radiated Emissions (Spurious/Harmonics) Under 1 GHz, Back View ....................................28 Page 4 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 1 General Information The following Class 2 Permissive Change Report is prepared on behalf of Harris Corporation in accordance with the FCC and ISED rules and regulations. The Equipment Under Test (EUT) was the XL-200P (International). All measurements contained in this application were conducted in accordance with the applicable sections of FCC Rules and Regulations CFR 47 Parts 2, 15, 22, 74, 80 and 90, and ISED RSS-119. Calibration checks are performed regularly on the instruments, and all accessories including high pass filter, coaxial attenuator, preamplifier and cables. 1.1 Test Facility The open area test site and conducted measurement facility used to collect the radiated data is located on the parking lot of Rhein Tech Laboratories, Inc. 360 Herndon Parkway, Suite 1400, Herndon, Virginia 20170. This site has been fully described in a report submitted to, and approved by, the Federal Communications Commission to perform AC line conducted and radiated emissions testing. 1.2 Related Submittal(s)/Grant(s) This is a Class 2 Permissive Change Report based on a change to a SKU reduction. The original FCC and ISED certifications were granted March 3 and March 7, 2016 respectively. Two additional models were approved November 20, 2017. Two emission designators were added to the FCC and ISED certifications on January 23, 2019 and January 8, 2019 respectively. The Harris model numbers currently included in this ISED family certification are: XL-PFM2M XL-PPM2M XL-PFM2Y XL-PPM2Y XL-PFM2B XL-PPM2B XL-PFM2G XL-PPM2G XL-PFM2P XL-PPM2P 2 Tested System Details The test sample was received on June 3, 2019. Listed below are the identifiers and descriptions of all equipment, cables, and internal devices used with the EUT for this test, as applicable. Table 2-1: Equipment Under Test (EUT) Part Radio Radio Antenna Full Spectrum LMR Manufacturer Harris Corporation Harris Corporation Harris Corporation Model XL-200P XL-200P Serial Number FCC ID A40302201644RW OWDTR-0145-E A40302201045RW OWDTR-0145-E RTL Bar Code 23254 23253 14035-4000-01 N/A N/A 23108 Page 5 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Table 2-2: Auxiliary Equipment Part Manufacturer Model Li-Ion Rechargeable Battery Li-Ion Rechargeable Battery Harris Corporation Harris Corporation 14035-4010 rev 14035-4010-05 rev Figure 2-1: Configuration of Tested System Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Part Number 009833 001897 FCC ID N/A RTL Bar Code 23103 N/A 23104 Antenna XL-200P (International) Harris XL-200P Page 6 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 2.1 EUT Exercise Description The EUT was supplied with the ability to change LMR, LTE, Bluetooth, and Wi-Fi frequencies for testing radiated emissions and collocation of various frequencies. The EUT was tested in all three orthogonal planes in order to determine worst-case emissions. The EUT was provided with software to continuously transmit during testing. The carrier was also checked to verify that information was being transmitted. There were no deviations from the test standard(s) and/or methods. The test results reported relate only to the item tested. The EUT was configured for testing in a manner simulating a typical end-user configuration. All circuitry, clocks, and oscillators were powered, and all functions were active. Applicable I/O ports to be cabled or loaded included Ethernet and data programming cables. For testing purposes, the EUT was programmed using a generic programming board. 2.2 Test Result Summary Table 2-3: Test Result Summary FCC Part 15 Subpart C Test Collocation Radiated Emissions FCC Reference FCC 15.209 Result Pass Page 7 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 3 FCC Part 2.1053(a): Field Strength of Spurious Radiation; Part 90.543: Out of Band Emissions Limit; RSS-Gen 6.13: Transmitter Unwanted Emissions 3.1 Test Procedure ANSI 63.26, section 5.5. The device uses digital modulation modulated to its maximum extent using a pseudo-random data sequence. The spurious emissions levels were measured, and the device under test was replaced by a substitution antenna connected to a signal generator. This signal generator level was then corrected by subtracting the cable loss from the substitution antenna to the signal generator, and the gain of the antenna (dBi) was added to achieve the EIRP level, then converted from the corrected signal generator level (dBm) to dBc, and compared to the limit. For emissions in the 1559-1610 band, Part 90.543(f) states: "For operations in the 763775 MHz and 793 805 MHz bands, all emissions including harmonics in the band 15591610 MHz shall be limited to -70dBW/MHz equivalent isotropically radiated power (EIRP) for wideband signals, and -80 dBW EIRP for discrete emissions of less than 700 Hz bandwidth. For the purpose of equipment authorization, a transmitter shall be tested with an antenna that is representative of the type that will be used with the equipment in normal operation." 3.2 Test Data Table 3-1: Field Strength of Spurious Radiation 136.000 MHz Frequency (MHz) 272.000 408.000 544.000 680.000 816.000 952.000 1088.000 1224.000 1360.000 Conducted Power 37.8 dBm; 6 W; Limit=50+10LogP=57.8 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 51.8 -27.9 0.2 -0.5 66.4 55.4 -25.5 0.2 -0.4 63.8 38.0 -42.0 0.2 -0.7 80.7 36.9 -42.8 0.2 -0.9 81.7 30.0 -41.8 0.2 -1.5 81.3 20.6 -54.1 0.2 -0.9 93.0 15.1 -61.5 0.2 2.6 96.9 14.1 -61.5 0.2 4.2 95.3 10.3 -64.6 0.3 4.7 97.9 Margin (dB) -8.6 -6.0 -22.9 -23.9 -23.5 -35.2 -39.1 -37.5 -40.1 Page 8 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-2: Field Strength of Spurious Radiation 138.000 MHz Frequency (MHz) 276.000 414.000 552.000 690.000 828.000 966.000 1104.000 1242.000 1380.000 Conducted Power 37.9 dBm; 6.2 W; Limit=50+10LogP=57.9 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 57.9 -23.7 0.2 -0.5 62.3 55.0 -24.7 0.2 -0.4 63.2 35.5 -43.5 0.2 -0.7 82.4 34.5 -44.5 0.2 -0.9 83.5 22.6 -52.0 0.2 -1.4 91.5 23.3 -50.4 0.2 -0.9 89.4 36.5 -39.0 0.2 3.0 74.1 16.9 -58.5 0.2 4.3 92.3 6.5 -67.6 0.3 4.8 101.0 Margin (dB) -4.4 -5.3 -24.5 -25.6 -33.6 -31.5 -16.2 -34.4 -43.1 Table 3-3: Field Strength of Spurious Radiation 141.000 MHz Frequency (MHz) 282.000 423.000 564.000 705.000 846.000 987.000 1128.000 1269.000 1410.000 Conducted Power 38.2 dBm; 6.6 W; Limit=50+10LogP=58.2 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 50.3 -31.3 0.2 -0.6 70.3 50.5 -28.8 0.2 -0.4 67.6 37.2 -43.1 0.2 -0.8 82.3 43.2 -35.7 0.2 -1.0 75.1 33.0 -45.6 0.2 -1.4 85.4 20.7 -53.3 0.2 -0.7 92.5 19.9 -55.9 0.2 3.3 91.1 12.5 -62.9 0.3 4.5 96.9 8.3 -67.2 0.3 4.9 100.8 Margin (dB) -12.1 -9.4 -24.1 -16.9 -27.2 -34.3 -32.9 -38.7 -42.6 Page 9 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-4: Field Strength of Spurious Radiation 144.000 MHz Frequency (MHz) 288.000 432.000 576.000 720.000 864.000 1008.000 1152.000 1296.000 1440.000 Conducted Power 38.3 d8Bm; 6 W; Limit=50+10LogP=58.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 53.2 -28.7 0.2 -0.6 67.8 45.6 -34.0 0.2 -0.4 73.0 23.2 -53.8 0.2 -0.8 93.2 35.7 -41.3 0.2 -1.0 80.9 18.5 -55.2 0.2 -1.4 95.1 21.6 -53.9 0.2 0.2 92.2 7.4 -68.1 0.2 3.6 103.0 14.9 -60.0 0.3 4.6 94.0 4.5 -69.2 0.3 5.1 102.7 Margin (dB) -9.5 -14.7 -34.9 -22.6 -36.8 -33.9 -44.7 -35.7 -44.4 Table 3-5: Field Strength of Spurious Radiation 148.000 MHz Frequency (MHz) 296.000 444.000 592.000 740.000 888.000 1036.000 1184.000 1332.000 1480.000 Conducted Power 38.3 d8Bm; 6 W; Limit=50+10LogP=58.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 45.3 -35.5 0.2 -0.7 74.7 52.8 -29.7 0.2 -0.4 68.7 36.6 -43.7 0.2 -0.8 83.0 34.2 -45.6 0.2 -1.2 85.3 17.8 -56.1 0.2 -1.3 95.9 17.7 -56.7 0.2 1.1 94.2 22.1 -54.0 0.2 3.9 88.6 4.4 -71.0 0.3 4.7 104.8 7.5 -67.2 0.3 5.3 100.4 Margin (dB) -16.4 -10.4 -24.7 -27.0 -37.6 -35.9 -30.3 -46.5 -42.1 Page 10 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-6: Field Strength of Spurious Radiation 150.000 MHz Frequency (MHz) 300.000 450.000 600.000 750.000 900.000 1050.000 1200.000 1350.000 1500.000 Conducted Power 38.3 d8Bm; 6 W; Limit=50+10LogP=58.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 46.6 -33.3 0.2 -0.7 72.6 43.8 -36.1 0.2 -0.4 75.0 9.0 -68.5 0.2 -0.8 107.8 17.8 -59.2 0.2 -1.2 99.0 3.7 -72.4 0.2 -1.2 112.2 2.5 -73.6 0.2 1.5 110.7 -2.0 -77.9 0.2 4.1 112.3 -5.7 -80.8 0.3 4.7 114.6 -10.0 -83.6 0.3 5.5 116.6 Margin (dB) -14.3 -16.7 -49.5 -40.7 -53.9 -52.4 -54.0 -56.3 -58.3 Table 3-7: Field Strength of Spurious Radiation 156.800 MHz Frequency (MHz) 313.600 470.400 627.200 784.000 940.800 1097.600 1254.400 1411.200 1568.000 Conducted Power 38.2 dBm; 6.6 W; Limit=50+10LogP=58.2 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 51.0 -31.2 0.2 -0.6 70.3 49.4 -32.4 0.2 -0.5 71.4 31.5 -44.4 0.2 -0.8 83.6 37.4 -42.0 0.2 -1.4 81.9 14.0 -60.8 0.2 -1.0 100.2 16.7 -59.5 0.2 2.9 95.1 7.0 -68.5 0.2 4.4 102.6 14.7 -59.9 0.3 4.9 93.5 -3.0 -77.2 0.3 6.4 109.3 Margin (dB) -12.1 -13.2 -25.4 -23.7 -42.0 -36.9 -44.4 -35.3 -51.1 Page 11 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-8: Field Strength of Spurious Radiation 162.000 MHz Frequency (MHz) 324.000 486.000 648.000 810.000 972.000 1134.000 1296.000 1458.000 1620.000 Conducted Power 38.1 dBm; 6.5 W; Limit=50+10LogP=58.1 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 58.1 -24.6 0.2 -0.6 63.5 52.3 -29.6 0.2 -0.6 68.5 24.5 -51.7 0.2 -0.8 90.9 35.0 -40.4 0.2 -1.5 80.2 8.0 -65.3 0.2 -0.9 104.5 17.7 -58.1 0.2 3.4 93.1 1.2 -73.6 0.3 4.6 107.4 17.1 -56.7 0.3 1.0 -73.5 0.3 5.2 89.8 6.9 105.0 Margin (dB) -5.4 -10.4 -32.8 -22.1 -46.4 -35.0 -49.3 -31.7 -46.9 Table 3-9: Field Strength of Spurious Radiation 174.000 MHz Frequency (MHz) 348.000 522.000 696.000 870.000 1044.000 1218.000 1392.000 1566.000 1740.000 Conducted Power 38.3 dBm; 6.8 W; Limit=50+10LogP=58.3dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 47.9 -35.0 0.2 -0.5 74.0 47.4 -33.0 0.2 -0.6 72.2 46.0 -33.0 0.2 -0.9 72.4 21.9 -52.4 0.2 -1.4 92.3 9.2 -66.8 0.2 1.3 104.1 11.6 -63.9 0.2 4.2 98.3 -8.7 -82.6 0.3 4.8 116.4 3.3 -70.9 0.3 6.3 103.1 13.0 -62.2 0.3 7.4 93.4 Margin (dB) -15.7 -13.9 -14.1 -34.0 -45.8 -40.0 -58.1 -44.8 -35.1 Page 12 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-10: Field Strength of Spurious Radiation 406.1000 MHz Frequency (MHz) 812.2000 1218.3000 1624.4000 2030.5000 2436.6000 2842.7000 3248.8000 3654.9000 4061.0000 Conducted Power 37.4 dBm; 5.5 W; Limit=50+10LogP=57.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 46.5 -31.7 0.2 -1.5 70.8 37.9 -36.9 0.2 6.9 67.6 10.7 -63.8 0.3 8.8 92.6 14.6 -59.6 0.3 8.8 88.5 11.8 -62.2 0.3 0.0 99.9 4.2 -70.5 0.3 10.0 98.2 2.9 -71.8 0.3 9.2 100.3 10.6 -62.9 0.3 9.5 91.2 -7.3 -78.2 0.4 10.0 106.0 Margin (dB) -13.4 -10.2 -35.2 -31.1 -42.5 -40.8 -42.9 -33.8 -48.6 Table 3-11: Field Strength of Spurious Radiation 418.0125 MHz Frequency (MHz) 836.0250 1254.0375 1672.0500 2090.0625 2508.0750 2926.0875 3344.1000 3762.1125 4180.1250 Conducted Power 37.3 dBm; 5.4 W; Limit=50+10LogP=57.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 39.8 -38.3 0.2 -1.4 77.3 30.6 -44.9 0.2 7.1 75.4 -3.2 -78.3 0.3 8.6 107.3 15.1 -60.0 0.3 8.5 89.1 -13.6 -87.6 0.3 9.5 115.7 -7.7 -81.5 0.3 0.0 119.2 -4.6 -78.3 0.3 9.4 106.5 2.4 -72.1 0.3 9.2 100.5 -7.0 -78.0 0.4 10.5 105.2 Margin (dB) -20.0 -18.1 -50.0 -31.8 -58.4 -61.9 -49.2 -43.2 -47.9 Page 13 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-12: Field Strength of Spurious Radiation 429.9875 MHz Frequency (MHz) 859.9750 1289.9625 1719.9500 2149.9375 2579.9250 3009.9125 3439.9000 3869.8875 4299.8750 Conducted Power 37.3 dBm; 5.4 W; Limit=50+10LogP=57.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 43.9 -33.7 0.2 -1.4 72.6 29.6 -45.3 0.3 7.2 75.6 4.5 -69.9 0.3 8.6 98.8 25.7 -49.0 0.3 8.7 77.8 9.0 -65.0 0.3 9.6 93.0 -1.8 -76.6 0.3 0.0 114.2 3.8 -69.8 0.3 9.7 97.8 6.4 -67.9 0.3 9.1 96.4 10.9 -60.2 0.4 10.9 87.0 Margin (dB) -15.3 -18.3 -41.5 -20.5 -35.7 -56.9 -40.5 -39.1 -29.7 Table 3-13: Field Strength of Spurious Radiation 450.0125 MHz Frequency (MHz) 900.0250 1350.0375 1800.0500 2250.0625 2700.0750 3150.0875 3600.1000 4050.1125 4500.1250 Conducted Power 37.4 dBm; 5.5 W; Limit=50+10LogP=57.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 40.6 -35.5 0.2 -1.2 74.4 36.0 -39.1 0.3 7.7 69.0 20.5 -53.8 0.3 8.8 82.7 27.9 -47.1 0.3 9.2 75.6 14.1 -59.8 0.3 0.0 97.5 20.7 -54.0 0.3 9.2 82.5 6.5 -67.1 0.3 9.7 95.1 4.9 -66.0 0.4 9.9 93.9 0.7 -70.6 0.4 11.0 97.4 Margin (dB) -17.0 -11.6 -25.3 -18.2 -40.1 -25.1 -37.7 -36.5 -40.0 Page 14 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-14: Field Strength of Spurious Radiation 459.9750 MHz Frequency (MHz) 919.9500 1379.9250 1839.9000 2299.8750 2759.8500 3219.8250 3679.8000 4139.7750 4599.7500 Conducted Power 37.3 dBm; 5.4 W; Limit=50+10LogP=57.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 52.0 -22.2 0.2 -1.2 60.9 33.9 -40.2 0.3 7.9 69.8 6.3 -68.0 0.3 8.6 96.9 18.4 -55.7 0.3 9.5 83.8 0.1 -73.8 0.3 0.0 111.4 3.0 -71.7 0.3 9.2 100.1 9.0 -65.5 0.3 9.4 93.7 11.2 -59.8 0.4 10.4 87.1 0.4 -71.3 0.4 11.0 97.9 Margin (dB) -3.6 -12.5 -39.6 -26.5 -54.1 -42.8 -36.4 -29.8 -40.6 Table 3-15: Field Strength of Spurious Radiation 469.9875 MHz Frequency (MHz) 939.9750 1409.9625 1879.9500 2349.9375 2819.9250 3289.9125 3759.9000 4229.8875 4699.8750 Conducted Power 37.4 dBm; 5.5 W; Limit=50+10LogP=57.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 43.6 -31.2 0.2 -1.0 69.8 39.1 -35.5 0.3 8.2 65.0 6.5 -67.8 0.3 8.5 97.0 15.8 -58.3 0.3 9.5 86.5 -1.7 -75.6 0.3 10.0 103.3 0.2 -74.5 0.3 9.2 102.9 7.2 -66.3 0.3 9.2 94.9 7.0 -64.4 0.4 10.7 91.4 1.4 -70.4 0.4 11.1 97.0 Margin (dB) -12.4 -7.6 -39.6 -29.1 -45.9 -45.5 -37.5 -34.0 -39.6 Page 15 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-16: Field Strength of Spurious Radiation 768.0125 MHz Frequency (MHz) 1536.0250 2304.0375 3072.0500 3840.0625 4608.0750 5376.0875 6144.1000 6912.1125 7680.1250 Conducted Power 34.3 dBm; 2.7 W; Limit=50+10LogP=54.3 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 24.9 -50.0 0.3 5.9 78.6 35.0 -39.1 0.3 7.7 66.0 12.8 -61.0 0.3 7.6 88.0 25.9 -48.6 0.3 7.3 75.9 8.4 -63.3 0.4 9.0 89.0 11.9 -59.9 0.4 8.6 86.0 10.0 -60.6 0.4 8.9 86.4 1.9 -68.0 0.5 9.0 93.7 1.6 -67.2 0.5 9.3 92.7 Margin (dB) -24.3 -11.7 -33.7 -21.6 -34.7 -31.7 -32.1 -39.4 -38.4 Table 3-17: Field Strength of Spurious Radiation 771.0125 MHz Frequency (MHz) 1542.0250 2313.0375 3084.0500 3855.0625 4626.0750 5397.0875 6168.1000 6939.1125 7710.1250 Conducted Power 34.4 dBm; 2.8 W; Limit=50+10LogP=54.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 26.0 -48.9 0.3 6.0 77.5 31.8 -42.3 0.3 7.7 69.3 11.1 -62.7 0.3 7.6 89.8 20.7 -52.8 0.3 7.3 80.2 9.8 -61.6 0.4 9.0 87.4 11.4 -60.4 0.4 8.6 86.6 3.6 -67.0 0.4 8.9 92.9 8.3 -61.8 0.5 9.1 87.6 -3.6 -72.4 0.5 9.4 97.9 Margin (dB) -23.1 -14.9 -35.4 -25.8 -33.0 -32.2 -38.5 -33.2 -43.5 Page 16 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-18: Field Strength of Spurious Radiation 775.9875 MHz Frequency (MHz) 1551.9750 2327.9625 3103.9500 3879.9375 4655.9250 5431.9125 6207.9000 6983.8875 7759.8750 Conducted Power 34.4 dBm; 2.8 W; Limit=50+10LogP=54.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 14.4 -59.7 0.3 6.2 88.2 33.0 -42.0 0.3 7.7 69.0 1.3 -73.4 0.3 7.5 100.6 18.9 -54.5 0.3 7.3 82.0 0.1 -71.3 0.4 9.0 97.1 -11.6 -83.4 0.4 8.6 109.6 -5.7 -76.3 0.4 8.9 102.2 -19.0 -88.8 0.5 9.2 114.5 -11.0 -80.4 0.5 9.4 105.9 Margin (dB) -33.8 -14.6 -46.2 -27.6 -42.7 -55.2 -47.8 -60.1 -51.5 Table 3-19: Field Strength of Spurious Radiation 798.0125 MHz Frequency (MHz) 1596.0250 2394.0375 3192.0500 3990.0625 4788.0750 5586.0875 6384.1000 7182.1125 7980.1250 Conducted Power 34.4 dBm; 2.8W; Limit=50+10LogP=54.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 22.3 -52.6 0.3 6.7 80.6 28.5 -46.5 0.3 7.6 73.6 6.6 -67.1 0.3 7.4 94.4 2.3 -71.1 0.4 7.5 98.3 10.0 -61.8 0.4 9.0 87.6 1.6 -69.6 0.4 8.9 95.5 -4.0 -74.4 0.4 9.2 100.1 -1.8 -71.4 0.5 9.1 97.2 -14.8 -83.4 0.5 9.3 109.0 Margin (dB) -26.2 -19.2 -40.0 -43.9 -33.2 -41.1 -45.7 -42.8 -54.6 Page 17 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-20: Field Strength of Spurious Radiation 801.0125 MHz Frequency (MHz) 1602.0250 2403.0375 3204.0500 4005.0625 4806.0750 5607.0875 6408.1000 7209.1125 8010.1250 Conducted Power 34.4 dBm; 2.8 W; Limit=50+10LogP=54.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 24.6 -50.4 0.3 6.8 78.3 42.4 -31.7 0.3 7.6 58.8 9.4 -64.3 0.3 7.4 91.7 -1.3 -72.5 0.4 7.6 99.7 12.0 -59.9 0.4 9.0 85.7 -0.5 -71.7 0.4 8.9 97.5 -4.6 -75.0 0.4 9.2 100.6 -14.0 -83.8 0.5 9.0 109.6 -13.7 -81.9 0.5 9.3 107.5 Margin (dB) -23.9 -4.4 -37.3 -45.3 -31.3 -43.1 -46.2 -55.2 -53.1 Table 3-21: Field Strength of Spurious Radiation 805.9875 MHz Frequency (MHz) 1611.9750 2417.9625 3223.9500 4029.9375 4835.9250 5641.9125 6447.9000 7253.8875 8059.8750 Conducted Power 34.4 dBm; 2.8 W; Limit=50+10LogP=54.4 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 25.7 -49.3 0.3 6.8 77.1 42.2 -31.9 0.3 7.6 58.9 7.5 -67.2 0.3 7.4 94.5 12.2 -59.0 0.4 7.7 86.1 12.6 -59.0 0.4 8.9 84.8 7.7 -63.4 0.4 9.0 89.3 -6.6 -76.9 0.4 9.2 102.6 -0.9 -70.4 0.5 8.9 96.4 -18.0 -84.1 0.5 9.3 109.7 Margin (dB) -22.7 -4.5 -40.1 -31.7 -30.4 -34.9 -48.2 -42.0 -55.3 Page 18 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-22: Field Strength of Spurious Radiation 806.0250 MHz Frequency (MHz) 1612.0500 2418.0750 3224.1000 4030.1250 4836.1500 5642.1750 6448.2000 7254.2250 8060.2500 Conducted Power 34.9 dBm; 3.1 W; Limit=50+10LogP=54.9 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 25.1 -49.4 0.3 6.8 77.7 23.6 -50.5 0.3 7.6 78.0 8.6 -65.1 0.3 7.4 93.0 -3.8 -74.7 0.4 7.7 102.3 13.0 -58.9 0.4 8.9 85.2 -3.0 -74.1 0.4 9.0 100.5 4.2 -66.1 0.4 9.2 92.3 -12.4 -82.2 0.5 8.9 108.6 -13.3 -79.4 0.5 9.3 105.5 Margin (dB) -22.8 -23.1 -38.1 -47.4 -30.3 -45.6 -37.4 -53.7 -50.6 Table 3-23: Field Strength of Spurious Radiation 809.0000 MHz Frequency (MHz) 1618.0000 2427.0000 3236.0000 4045.0000 4854.0000 5663.0000 6472.0000 7281.0000 8090.0000 Conducted Power 35 dBm; 3.2 W; Limit=50+10LogP=55 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 12.6 -61.9 0.3 6.9 90.3 4.5 -70.5 0.3 7.6 98.1 -1.5 -75.2 0.3 7.4 103.2 -4.3 -75.2 0.4 7.8 102.8 5.4 -66.5 0.4 8.9 92.9 -8.9 -80.0 0.4 9.0 106.4 -5.6 -75.9 0.4 9.2 102.1 -9.1 -78.6 0.5 8.8 105.3 -7.5 -72.4 0.5 9.4 98.5 Margin (dB) -35.3 -43.1 -48.2 -47.8 -37.9 -51.4 -47.1 -50.3 -43.5 Page 19 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-24: Field Strength of Spurious Radiation 815.9875 MHz Frequency (MHz) 1631.9750 2447.9625 3263.9500 4079.9375 4895.9250 5711.9125 6527.9000 7343.8875 8159.8750 Conducted Power 35bdBm; 3.2 W; Limit=50+10LogP=55 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 25.5 -49.6 0.3 7.0 77.9 38.4 -36.6 0.3 7.7 64.2 10.0 -63.7 0.3 7.3 91.7 10.6 -60.7 0.4 7.9 88.1 12.4 -59.3 0.4 8.9 85.8 17.5 -54.0 0.4 9.1 80.3 -4.7 -75.0 0.4 9.2 101.2 -0.8 -70.3 0.5 8.8 97.0 -7.8 -69.8 0.5 9.4 95.8 Margin (dB) -22.9 -9.2 -36.7 -33.1 -30.8 -25.3 -46.2 -42.0 -40.8 Table 3-25: Field Strength of Spurious Radiation 851.0250 MHz Frequency (MHz) 1702.0500 2553.0750 3404.1000 4255.1250 5106.1500 5957.1750 6808.2000 7659.2250 8510.2500 Conducted Power 34.9 dBm; 3.1 W; Limit=50+10LogP=54.9 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 20.9 -53.5 0.3 7.4 81.2 21.1 -52.9 0.3 7.6 80.5 14.2 -60.4 0.3 7.6 88.1 1.3 -70.1 0.4 8.6 96.8 -0.3 -72.0 0.4 8.6 98.6 1.7 -69.5 0.4 9.0 95.8 -3.9 -73.9 0.5 8.8 100.4 -8.1 -76.9 0.5 9.3 103.0 -7.0 -68.1 0.5 9.3 94.2 Margin (dB) -26.3 -25.6 -33.2 -41.9 -43.7 -40.9 -45.5 -48.1 -39.3 Page 20 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Table 3-26: Field Strength of Spurious Radiation 856.0250 MHz Frequency (MHz) 1712.0500 2568.0750 3424.1000 4280.1250 5136.1500 5992.1750 6848.2000 7704.2250 8560.2500 Conducted Power 35 dBm; 3.2 W; Limit=50+10LogP=55 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 21.6 -52.8 0.3 7.4 80.6 37.2 -37.7 0.3 7.6 65.4 10.3 -63.3 0.3 7.6 91.1 5.9 -65.2 0.4 8.6 92.0 4.0 -67.6 0.4 8.6 94.4 6.2 -65.0 0.4 9.0 91.4 -1.6 -71.8 0.5 8.9 98.4 -2.1 -70.9 0.5 9.4 97.0 -7.3 -68.5 0.5 9.3 94.8 Margin (dB) -25.6 -10.4 -36.1 -37.0 -39.4 -36.4 -43.4 -42.0 -39.8 Table 3-27: Field Strength of Spurious Radiation 860.9875 MHz Frequency (MHz) 1721.9750 2582.9625 3443.9500 4304.9375 5165.9250 6026.9125 6887.9000 7748.8875 8609.8750 Conducted Power 35 dBm; 3.2 W; Limit=50+10LogP=55 dBc Analyzer Level (dBuV) Signal Generator Level (dBm) Cable Loss to Transmit Antenna (dB) Substitution Antenna Normalized Gain (dBi) Corrected Signal Generator Level (dBc) 18.4 -56.0 0.3 7.4 83.8 17.9 -57.0 0.3 7.6 84.8 13.6 -61.0 0.3 7.7 88.7 8.8 -62.6 0.4 8.7 89.3 16.3 -55.8 0.4 8.6 82.6 9.8 -61.0 0.4 9.0 87.4 3.3 -66.6 0.5 8.9 93.1 -3.2 -72.6 0.5 9.4 98.7 -7.4 -68.8 0.5 9.3 95.0 Margin (dB) -28.8 -29.8 -33.7 -34.3 -27.6 -32.4 -38.1 -43.7 -40.0 Page 21 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Table 3-28: Part 90.543(f): Out of Band Emissions Limit Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Fundamental Frequency (MHz) 798.0125 801.0125 Second Harmonic Frequency (MHz) 1596.025 1602.025 Spectrum Analyzer Level (dBuV) 22.3 24.6 Signal Generator Level (dBm) -52.6 -50.4 Cable Loss to Transmit Antenna (dB) 0.3 0.3 Substitution Antenna Gain (dBi) 6.7 6.8 Corrected Signal Generator Level (dBW) -76.2 -73.9 Limit Margin (dBW) (dB) -70 -6.2 -70 -3.9 Table 3-29: FCC Unintentional Digital/RX Emissions Frequency (MHz) 49.317 58.280 63.388 77.346 86.560 91.288 105.711 133.837 147.000 231.731 351.763 502.404 654.327 775.003 Analyzer Level (dBuV) 40.6 55.1 42.7 44.3 42.1 45.6 41.0 39.1 38.2 32.7 32.3 32.0 33.1 31.5 Site Correction Factor (dB/m) -17.6 -21.5 -21.7 -20.6 -18.4 -17.4 -14.7 -14.7 -15.4 -14.6 -9.2 -5.1 -2.2 -0.1 Corrected Level (dBuV/m) 23.0 33.6 21.0 23.7 23.7 28.2 26.3 24.4 22.8 18.1 23.1 26.9 30.9 31.4 Limit (dBuV/m) 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 43.5 46.0 46.0 46.0 46.0 46.0 Margin (dB) -17.0 -6.4 -19.0 -16.3 -16.3 -15.3 -17.2 -19.1 -20.7 -27.9 -22.9 -19.1 -15.1 -14.6 Measurement uncertainties shown for these tests are expanded uncertainties expressed at the 95% confidence level using a coverage factor K=2. Measurement uncertainty: ±4.6 dB Page 22 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Table 3-30: Collocation Frequencies Tested LMR (MHz) 138, 156.8, 174 418.0125, 450.0125, 469.9875 768.0125, 775.9875, 805.9875 806.025, 815.9875, 860.9875 Bluetooth (MHz) 2402 2440 2480 Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Wi-Fi (MHz) 2412 2437 2462 LTE Cellular (MHz) 2500 2535 2570 Note: Radiated emissions were investigated with the modules collocated and transmitting simultaneously with the LMR, Bluetooth, Wi-Fi, and LTE transceivers. No non-compliant emissions were found; per FCC guidance, no data is being reported. Table 3-31: Test Equipment Used For Testing Field Strength of Spurious Radiation and Unintentional Emissions RTL Asset # 900878 901729 901593 901242 900791 900321 900323 900772 901582 901581 901129 901131 901135 900814 Manufacturer Rhein Tech Laboratories Insulated Wire Inc. Insulated Wire Inc. Rhein Tech Laboratories Chase Model AM3-1197-0005 KPS-1503-3150- KPR KPS-1503-360-KPR WRT-000-0003 CBL6111B EMCO 3161-03 EMCO 3160-07 EMCO Rohde & Schwarz Rohde & Schwarz Par Electronics Par Electronics Par Electronics 3161-02 1167.0000.02 FSU 806-902 (25W) 118-174 (25W) 400-512 (25W) Electro-Metrics EM-6961 (RGA-60) Part Type 3 meter antenna mast, polarizing SMK RF Cables 20' SMK RF Cables 36" Wood rotating table Bilog Antenna (30 MHz 2000 MHz) Horn Antenna (4.0 - 8.2 GHz) Horn Antenna (8.2 - 12.4 GHz) Horn Antenna (2 - 4 GHz) Signal Generator Spectrum Analyzer UHF Notch Filter VHF Notch Filter UHF Notch Filter Double Ridged Guide Antenna (1 - 18 GHz) Serial Number OATS1 NA NA N/A N/A 9508-1020 9605-1054 9804-1044 101903 1166.1660.50 N/A N/A N/A 2310 Calibration Due Date N/A 8/21/19 8/21/19 N/A 10/4/20 5/17/21 5/17/21 5/17/21 4/24/21 4/26/21 8/10/19 8/10/19 8/10/19 4/7/22 Page 23 of 28 Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA20170 http://www.rheintech.com Test Personnel: Client: Harris Corporation Model: XL-200P (International) IDs: OWDTR-0145-E/3636B-0145 Standard: FCC Part 90/ISED RSS-119 Report #: 2019070 Daniel Baltzell Test Engineer Signature June 11, 2019 Date of Tests 4 Conclusion The data in this measurement report shows that the harmonic emissions levels and intermodulation frequencies for collocation testing were passing for the Harris Corporation XL-200P (International), FCC ID: OWDTR-0145-E, IC: 3636B-0145. Page 24 of 28
Related FCC IDs:
- OWDTR-0145-E - HARRIS CORPORATION Multi-band portable radio with Bluetooth & Wi-Fi [TR-0145-E] Adobe PDF Library 15.0