Test Report

Report No.: MTi240314002-02E1

Date of issue: 2024-05-17

Applicant:

U2O GLOBAL CO., LTD.

Product:

StandMe Power

Model(s):

MXS007

FCC ID:

SXQ-MXS007

Shenzhen Microtest Co., Ltd. http://www.mtitest.cn

The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only.

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 2 of 27

Report No.: MTi240314002-02E1

Instructions
1. This test report shall not be partially reproduced without the written consent of the laboratory.
2. The test results in this test report are only responsible for the samples submitted
3. This test report is invalid without the seal and signature of the laboratory.
4. This test report is invalid if transferred, altered, or tampered with in any form without authorization.
5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report.

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 3 of 27

Report No.: MTi240314002-02E1

Table of contents
1 General Description .........................................................................................................................5
1.1 Description of the EUT...............................................................................................................................5 1.2 Description of test modes ..........................................................................................................................5 1.3 Environmental Conditions..........................................................................................................................7 1.4 Description of support units .......................................................................................................................7 1.5 Measurement uncertainty ..........................................................................................................................7
2 Summary of Test Result ..................................................................................................................8 3 Test Facilities and accreditations ...................................................................................................9
3.1 Test laboratory ...........................................................................................................................................9
4 List of test equipment....................................................................................................................10 5 Evaluation Results (Evaluation)....................................................................................................11
5.1 Antenna requirement ...............................................................................................................................11
6 Radio Spectrum Matter Test Results (RF) ....................................................................................12
6.1 Conducted Emission at AC power line ....................................................................................................12 6.2 20dB Occupied Bandwidth ......................................................................................................................15 6.3 Emissions in frequency bands (below 30MHz)........................................................................................20 6.4 Emissions in frequency bands (30MHz - 1GHz)......................................................................................23
Photographs of the test setup .............................................................................................................26 Photographs of the EUT.......................................................................................................................27

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Applicant: Address: Manufacturer: Address: Product description Product name: Trade mark: Model name: Series Model(s): Standards: Test Method: Date of Test Date of test: Test result:

Page 4 of 27

Report No.: MTi240314002-02E1

Test Result Certification
U2O GLOBAL CO., LTD. U2O building, Huanzhu Road 385, Jimei district Xiamen, Fujian, China U2O GLOBAL CO., LTD. U2O building, Huanzhu Road 385, Jimei district Xiamen, Fujian, China

StandMe Power N/A MXS007 N/A 47 CFR Part 15C ANSI C63.10-2013

2024-03-28 to 2024-04-16 Pass

Test Engineer : Reviewed By : Approved By :

(Yanice.Xie) (David Lee) (Leon Chen)

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 5 of 27

Report No.: MTi240314002-02E1

1 General Description

1.1 Description of the EUT

Product name:

StandMe Power

Model name:

MXS007

Series Model(s):

N/A

Model difference: Electrical rating:
Accessories: Hardware version:

N/A
Input:DC 5V/3A,9V/3A Wireless Charging:15W (7.5W for iPhone+5W for Airpods+2.5W for Watch)
1.Adaptor: Model NO.: RCE-2004CLM Output Power:20W Max Input:110-240V~ 50/60Hz 0.5A Output:DC 5V/3A,9V/2.22A, 12V/1.67A 2.Cable: Type-C to Type-C 1.5m
IP6862+GWWDSC(SC9608)

Software version:

V10-XCTOA+OX479FC309

Test sample(s) number: MTi240314002-02S1001

RF specification
Operating frequency range:
Modulation type:

Coil1 (Phone): 115-205kHz Coil2 (Earphone): 115-205kHz Coil3(Watch): 300-350kHz
ASK

Antenna(s) type:

Coil antenna

1.2 Description of test modes No.
Mode1 Mode2 Mode3 Mode4 Mode5 Mode6 Mode7 Mode8 Mode9 Mode10 Mode11 Mode12 Mode13 Mode14

Emission test modes Wireless output(5W)+Airpods(5W)+Watch(2.5W) Wireless output(7.5W)+Airpods(5W)+Watch(2.5W)
Wireless output(5W)+Airpods(5W) Wireless output(7.5W)+Airpods(5W) Wireless output(10W)+Airpods(5W) Wireless output(5W)+Watch(2.5W) Wireless output(7.5W)+Watch(2.5W) Wireless output(10W)+Watch(2.5W)
Airpods(5W)+Watch(2.5W) Wireless output(5W) Wireless output(7.5W) Wireless output(10W) Wireless output(15W) Watch(2.5W)

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Mode15 Mode16

Page 6 of 27
Airpods(3W) Stand by

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 7 of 27

Report No.: MTi240314002-02E1

1.3 Environmental Conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:

15°C ~ 35°C

Humidity:

20% RH ~ 75% RH

Atmospheric pressure: 98 kPa ~ 101 kPa

1.4 Description of support units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.
Support equipment list

Description

Model

Serial No.

Manufacturer

wireless charging load

YBZ1.1

/

YBZ

iwatch Air Pods

iwatch S7 MQD83CH/A

M0JVGQG1VP /

Apple Apple

Support cable list

Description

Length (m)

From

To

/

/

/

/

1.5 Measurement uncertainty

Measurement Conducted emissions (AMN 150kHz~30MHz) Occupied channel bandwidth Radiated spurious emissions (9kHz~30MHz) Radiated spurious emissions (30MHz~1GHz) Temperature Humidity

±3.1dB ±3 % ±4.3dB ±4.7dB ±1 °C ± 5 %

Uncertainty

This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 8 of 27

2 Summary of Test Result

No. Item

Standard

1 Antenna requirement

47 CFR Part 15C

2

Conducted Emission at AC power line

47 CFR Part 15C

3 20dB Occupied Bandwidth 47 CFR Part 15C

4

Emissions in frequency bands (below 30MHz)

47 CFR Part 15C

5

Emissions in frequency bands (30MHz - 1GHz)

47 CFR Part 15C

Report No.: MTi240314002-02E1

Requirement 47 CFR Part 15.203

Result Pass

47 CFR Part 15.207(a) Pass

47 CFR Part 15.215(c) Pass

47 CFR Part 15.209 Pass

47 CFR Part 15.209 Pass

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 9 of 27

Report No.: MTi240314002-02E1

3 Test Facilities and accreditations
3.1 Test laboratory

Test laboratory: Test site location: Telephone:

Shenzhen Microtest Co., Ltd.
101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China
(86-755)88850135

Fax:

(86-755)88850136

CNAS Registration No.: CNAS L5868

FCC Registration No.: 448573

IC Registration No.:

21760

CABID:

CN0093

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 10 of 27

Report No.: MTi240314002-02E1

4 List of test equipment

No.

Equipment

Manufacturer

Model

Serial No.

Cal. date Cal. Due

Conducted Emission at AC power line

1

EMI Test Receiver

Rohde&schwarz

ESCI3

101368

2023-04-26 2024-04-25

2 Artificial mains network Schwarzbeck NSLK 8127

183

2023-05-05 2024-05-04

3 Artificial Mains Network

Rohde & Schwarz

ESH2-Z5

100263

2023-06-03 2024-06-02

20dB Occupied Bandwidth

1

Wideband Radio Communication Tester

Rohde&schwarz

CMW500

149155

2023-04-26 2024-04-25

2

ESG Series Analog Ssignal Generator

Agilent

E4421B

GB40051240 2023-04-25 2024-04-24

3

PXA Signal Analyzer

Agilent

N9030A

MY51350296 2023-04-25 2024-04-24

4 Synthesized Sweeper

Agilent

83752A

3610A01957 2023-04-25 2024-04-24

5 MXA Signal Analyzer

Agilent

N9020A

MY50143483 2023-04-26 2024-04-25

6

RF Control Unit

Tonscend

JS0806-1 19D8060152 2023-04-26 2024-04-25

7 Band Reject Filter Group

8

ESG Vector Signal Generator

9

DC Power Supply

Tonscend Agilent Agilent

JS0806-F N5182A E3632A

19D8060160 2023-05-05 2024-05-04 MY50143762 2023-04-25 2024-04-24 MY40027695 2023-05-05 2024-05-04

Emissions in frequency bands (below 30MHz)

1

EMI Test Receiver

Rohde&schwarz

ESCI7

101166

2023-04-26 2024-04-25

2

Active Loop Antenna

Schwarzbeck FMZB 1519 B

00066

2023-06-11 2025-06-10

3

Amplifier

Hewlett-Packard

8447F

3113A06184 2023-04-25 2024-04-24

Emissions in frequency bands (30MHz - 1GHz)

1

EMI Test Receiver

Rohde&schwarz

ESCI7

101166

2023-04-26 2024-04-25

2

TRILOG Broadband Antenna

schwarabeck VULB 9163 9163-1338 2023-06-11 2025-06-10

3

Active Loop Antenna

Schwarzbeck FMZB 1519 B

00066

2023-06-11 2025-06-10

4

Amplifier

Hewlett-Packard

8447F

3113A06184 2023-04-25 2024-04-24

5 Multi-device Controller

TuoPu

TPMDC

/

2023-05-04 2024-05-03

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 11 of 27

Report No.: MTi240314002-02E1

5 Evaluation Results (Evaluation)

5.1 Antenna requirement

Test Requirement:

Refer to 47 CFR Part 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.

5.1.1 Conclusion:
The antenna of the EUT is permanently attached. The EUT complies with the requirement of FCC PART 15.203.

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 12 of 27

Report No.: MTi240314002-02E1

6 Radio Spectrum Matter Test Results (RF)

6.1 Conducted Emission at AC power line

Test Requirement: Test Limit:
Test Method: Procedure:

Except as shown in paragraphs (b)and (c)of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed the limits in the following table, as measured using a 50 H/50 ohms line impedance stabilization network (LISN).

Frequency of emission (MHz)
0.15-0.5 0.5-5 5-30

Conducted limit (dBV)

Quasi-peak

Average

66 to 56*

56 to 46*

56

46

60

50

*Decreases with the logarithm of the frequency.

ANSI C63.10-2013 section 6.2

Refer to ANSI C63.10-2013 section 6.2, standard test method for ac powerline conducted emissions from unlicensed wireless devices

6.1.1 E.U.T. Operation:

Operating Environment:

Temperature: 25.9 °C

Humidity: 44 %

Atmospheric Pressure: 101 kPa

Pre test mode: Final test mode:

Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8, Mode9, Mode10, Mode11, Mode12, Mode13, Mode14, Mode15, Mode16 All of the listed pre-test mode were tested, only the data of the worst mode (Mode2) is recorded in the report

6.1.2 Test Setup Diagram:

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

6.1.3 Test Data: Mode2 / Line: Line

Page 13 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Mode2 / Line: Neutral

Page 14 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 15 of 27

Report No.: MTi240314002-02E1

6.2 20dB Occupied Bandwidth

Test Requirement: Test Limit:

47 CFR Part 15.215(c)
Refer to 47 CFR 15.215(c), intentional radiators operating under the alternative provisions to the general emission limits, as contained in §§ 15.217 through 15.257 and in subpart E of this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated.

Test Method: Procedure:

ANSI C63.10-2013, section 6.9.2
a) The spectrum analyzer center frequency is set to the nominal EUT channel center frequency. The span range for the EMI receiver or spectrum analyzer shall be between two times and five times the OBW. b) The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video bandwidth (VBW) shall be approximately three times RBW, unless otherwise specified by the applicable requirement. c) Set the reference level of the instrument as required, keeping the signal from exceeding the maximum input mixer level for linear operation. In general, the peak of the spectral envelope shall be more than [10 log (OBW/RBW)] below the reference level. Specific guidance is given in 4.1.5.2. d) Steps a) through c) might require iteration to adjust within the specified tolerances. e) The dynamic range of the instrument at the selected RBW shall be more than 10 dB below the target "-xx dB down" requirement; that is, if the requirement calls for measuring the -20 dB OBW, the instrument noise floor at the selected RBW shall be at least 30 dB below the reference value. f) Set detection mode to peak and trace mode to max hold. g) Determine the reference value: Set the EUT to transmit an unmodulated carrier or modulated signal, as applicable. Allow the trace to stabilize. Set the spectrum analyzer marker to the highest level of the displayed trace (this is the reference value). h) Determine the "-xx dB down amplitude" using [(reference value) - xx]. Alternatively, this calculation may be made by using the marker-delta function of the instrument. i) If the reference value is determined by an unmodulated carrier, then turn the EUT modulation ON, and either clear the existing trace or start a new trace on the spectrum analyzer and allow the new trace to stabilize. Otherwise, the trace from step g) shall be used for step j). j) Place two markers, one at the lowest frequency and the other at the highest frequency of the envelope of the spectral display, such that each marker is at or slightly below the "-xx dB down amplitude" determined in step h). If a marker is below this "-xx dB down amplitude" value, then it shall be as close as possible to this value. The occupied bandwidth is the frequency difference between the two markers. Alternatively, set a marker at the lowest frequency of the envelope of the spectral display, such that the marker is at or slightly below the "-xx dB down amplitude" determined in step h). Reset the markerdelta function and move the marker to the other side of the emission until the delta marker amplitude is at the same level as the reference marker amplitude. The marker-delta frequency reading at this point is the specified emission bandwidth. k) The occupied bandwidth shall be reported by providing plot(s) of the measuring instrument display; the plot axes and the scale units per division shall be clearly labeled. Tabular data may be reported in addition to the plot(s).

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 16 of 27

Report No.: MTi240314002-02E1

6.2.1 E.U.T. Operation:

Operating Environment:

Temperature: 21.8 °C

Humidity: 52.3 %

Atmospheric Pressure: 98 kPa

Pre test mode:

Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8, Mode9, Mode10, Mode11, Mode12, Mode13, Mode14, Mode15, Mode16

Final test mode:

All of the listed pre-test mode were tested, only the data of the worst mode (Mode2) is recorded in the report

6.2.2 Test Setup Diagram:

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 17 of 27

Report No.: MTi240314002-02E1

6.2.3 Test Data:

Note: Because the measured signal is CW-like, adjusting the RBW per C63.10 would not be practical since measurement bandwidth will always follow the RBW. The RBW is set to 300 Hz to perform the occupied bandwidth test.

Coil 1

Frequency kHz

20 dB occupied bandwidth Hz

99% occupied bandwidth Hz

138.205

813

691

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 18 of 27

Report No.: MTi240314002-02E1

Note: Because the measured signal is CW-like, adjusting the RBW per C63.10 would not be practical since measurement bandwidth will always follow the RBW. The RBW is set to 300 Hz to perform the occupied bandwidth test.

Coil 2

Frequency kHz

20 dB occupied bandwidth Hz

99% occupied bandwidth Hz

142.705

810

693

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 19 of 27

Report No.: MTi240314002-02E1

Note: Because the measured signal is CW-like, adjusting the RBW per C63.10 would not be practical since measurement bandwidth will always follow the RBW. The RBW is set to 300 Hz to perform the occupied bandwidth test.

Coil 3

Frequency kHz

20 dB occupied bandwidth Hz

99% occupied bandwidth Hz

320.8

817

702

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 20 of 27

Report No.: MTi240314002-02E1

6.3 Emissions in frequency bands (below 30MHz)

Test Requirement: Test Limit:
Test Method: Procedure:

47 CFR Part 15.209

Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measuremen t distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. As shown in § 15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)and (b)of this section are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For point-to-point operation under paragraph (b)of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

ANSI C63.10-2013 section 6.4

ANSI C63.10-2013 section 6.4

6.3.1 E.U.T. Operation:

Operating Environment:

Temperature: 22.5 °C

Humidity: 43 %

Atmospheric Pressure: 101 kPa

Pre test mode:

Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8, Mode9, Mode10, Mode11, Mode12, Mode13, Mode14, Mode15, Mode16

Final test mode:

All of the listed pre-test mode were tested, only the data of the worst mode (Mode2) is recorded in the report

6.3.2 Test Setup Diagram:

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

6.3.3 Test Data: Mode2 / Polarization: coplane

Page 21 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Mode2 / Polarization: coplane

Page 22 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Page 23 of 27

Report No.: MTi240314002-02E1

6.4 Emissions in frequency bands (30MHz - 1GHz)

Test Requirement: Test Limit:
Test Method: Procedure:

47 CFR Part 15.209

Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measuremen t distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. As shown in § 15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)and (b)of this section are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For point-to-point operation under paragraph (b)of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

ANSI C63.10-2013 section 6.5

ANSI C63.10-2013 section 6.5

6.4.1 E.U.T. Operation:

Operating Environment:

Temperature: 22.5 °C

Humidity: 43 %

Atmospheric Pressure: 101 kPa

Pre test mode:

Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8, Mode9, Mode10, Mode11, Mode12, Mode13, Mode14, Mode15, Mode16

Final test mode:

All of the listed pre-test mode were tested, only the data of the worst mode (Mode8) is recorded in the report

6.4.2 Test Setup Diagram:

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

6.4.3 Test Data: Mode8 / Polarization: Horizontal

Page 24 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Mode8 / Polarization: Vertical

Page 25 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Photographs of the test setup
Refer to Appendix - Test Setup Photos.

Page 26 of 27

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]

Photographs of the EUT
Refer to Appendix - EUT Photos

Page 27 of 27 ----End of Report----

Report No.: MTi240314002-02E1

Address: Headquarters: Microtest Hi-tech Building, Zone 2, Xinxing Industrial Park, Fuzhou Avenue, Bao'an District, Shenzhen, China.

Tel: (86-755)88850135

Fax: (86-755) 88850136

Web: www.mtitest.cn

E-mail: [email protected]



Related FCC IDs:

Search Any Device: