UL-SAR
App C Highest Test Plots
Sun Cupid Technology (HK) Ltd. S6603L 2ADINS6603L 2ADINS6603L s6603l
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 39 Pages, 1.18MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7671228Date: 2024/8/14 GSM 850 Head Communication System: UID 0, GPRS 2TS (0); Communication System Band: GSM 850; Frequency: 836.6 MHz; Medium parameters used (interpolated): f = 836.6 MHz; = 0.885 S/m; r = 40.599; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.145 W/kg Configuration/Head/Zoom Scan (7x8x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.063 V/m; Power Drift = 0.02dB Peak SAR (extrapolated) = 0.194 W/kg SAR(1 g) = 0.112 W/kg; SAR(10 g) = 0.084 W/kg Maximum value of SAR (measured) = 0.146 W/kg Date: 2024/8/26 GSM 850 Body Communication System: UID 0, GPRS 2TS (0); Communication System Band: GSM 850; Frequency: 836.6 MHz; Medium parameters used (interpolated): f = 836.6 MHz; = 0.888 S/m; r = 41.099; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (10x15x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.382 W/kg Configuration/Body/Zoom Scan (6x6x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 14.73 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 0.587 W/kg SAR(1 g) = 0.310 W/kg; SAR(10 g) = 0.176 W/kg Maximum value of SAR (measured) = 0.470 W/kg Date: 2024/8/14 GSM 1900 Head Communication System: UID 0, GPRS 3TS (0); Communication System Band: GSM 1900; Frequency: 1880 MHz; Medium parameters used: f = 1880 MHz; = 1.451 S/m; r = 39.062; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.136 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 2.091 V/m; Power Drift = 0.15 dB Peak SAR (extrapolated) = 0.166 W/kg SAR(1 g) = 0.101 W/kg; SAR(10 g) = 0.062 W/kg Maximum value of SAR (measured) = 0.140 W/kg Date: 2024/8/29 GSM 1900 Body Communication System: UID 0, GPRS 3TS (0); Communication System Band: GSM 1900; Frequency: 1880 MHz; Medium parameters used: f = 1880 MHz; = 1.451 S/m; r = 39.974; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.00 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 27.82 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 1.30 W/kg SAR(1 g) = 0.721 W/kg; SAR(10 g) = 0.387 W/kg Maximum value of SAR (measured) = 1.09 W/kg Date: 2024/8/14 WCDMA B2 Head Communication System: UID 0, UMTS-FDD(WCDMA) (0); Communication System Band: Band 2; Frequency: 1880 MHz; Medium parameters used: f = 1880 MHz; = 1.451 S/m; r = 39.062; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.113 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 1.897 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 0.138 W/kg SAR(1 g) = 0.082 W/kg; SAR(10 g) = 0.049 W/kg Maximum value of SAR (measured) = 0.117 W/kg Date: 2024/8/29 WCDMA B2 Body Communication System: UID 0, UMTS-FDD(WCDMA) (0); Communication System Band: Band 2; Frequency: 1907.6 MHz; Medium parameters used (extrapolated): f = 1907.6 MHz; = 1.446 S/m; r = 39.956; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.959 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 26.39 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 1.34 W/kg SAR(1 g) = 0.741 W/kg; SAR(10 g) = 0.396 W/kg Maximum value of SAR (measured) = 1.12 W/kg Date: 2024/8/14 WCDMA B4 Head Communication System: UID 0, UMTS-FDD(WCDMA) (0); Communication System Band: Band 4; Frequency: 1732.6 MHz; Medium parameters used (interpolated): f = 1732.6 MHz; = 1.403 S/m; r = 39.049; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.76, 8.76, 8.76); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.125 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.422 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.147 W/kg SAR(1 g) = 0.099 W/kg; SAR(10 g) = 0.064 W/kg Maximum value of SAR (measured) = 0.131 W/kg Date: 2024/8/26 WCDMA B4 Body Communication System: UID 0, UMTS-FDD(WCDMA) (0); Communication System Band: Band 4; Frequency: 1732.6 MHz; Medium parameters used (interpolated): f = 1732.6 MHz; = 1.409 S/m; r = 39.549; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.76, 8.76, 8.76); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.418 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 18.49 V/m; Power Drift = -0.15 dB Peak SAR (extrapolated) = 0.689 W/kg SAR(1 g) = 0.422 W/kg; SAR(10 g) = 0.228 W/kg Maximum value of SAR (measured) = 0.594 W/kg Date: 2024/8/14 WCDMA B5 Head Communication System: UID 0, UMTS-FDD(WCDMA) (0); Communication System Band: Band 5; Frequency: 836.6 MHz; Medium parameters used (interpolated): f = 836.6 MHz; = 0.885 S/m; r = 40.599; = 1000 kg/m3 Phantom section: Right Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.154 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.298 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 0.171 W/kg SAR(1 g) = 0.121 W/kg; SAR(10 g) = 0.088 W/kg Maximum value of SAR (measured) = 0.153 W/kg Date: 2024/8/26 WCDMA B5 Body Communication System: UID 0, UMTS-FDD(WCDMA) (0); Communication System Band: Band 5; Frequency: 836.6 MHz; Medium parameters used (interpolated): f = 836.6 MHz; = 0.888 S/m; r = 41.099; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (10x15x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.282 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 12.76 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.442 W/kg SAR(1 g) = 0.240 W/kg; SAR(10 g) = 0.137 W/kg Maximum value of SAR (measured) = 0.363 W/kg Date: 2024/8/26 LTE B2 Head Communication System: UID 0, LTE (0); Communication System Band: Band 2; Frequency: 1900 MHz; Medium parameters used: f = 1900 MHz; = 1.401 S/m; r = 39.069; = 1000 kg/m3 Phantom section: Right Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.0441 W/kg Configuration/Head/Zoom Scan (8x10x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.0710 W/kg SAR(1 g) = 0.031 W/kg; SAR(10 g) = 0.019 W/kg Maximum value of SAR (measured) = 0.0444 W/kg Date: 2024/8/29 LTE B2 Body Communication System: UID 0, LTE (0); Communication System Band: Band 2; Frequency: 1900 MHz; Medium parameters used: f = 1900 MHz; = 1.408 S/m; r = 39.481; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.07 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 28.34 V/m; Power Drift = -0.15 dB Peak SAR (extrapolated) = 1.53 W/kg SAR(1 g) = 0.848 W/kg; SAR(10 g) = 0.454 W/kg Maximum value of SAR (measured) = 1.28 W/kg Date: 2024/8/26 LTE B4 Body Communication System: UID 0, LTE (0); Communication System Band: Band 4; Frequency: 1720 MHz; Medium parameters used: f = 1720 MHz; = 1.403 S/m; r = 39.592; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.76, 8.76, 8.76); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.421 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 18.52 V/m; Power Drift = 0.15 dB Peak SAR (extrapolated) = 0.733 W/kg SAR(1 g) = 0.451 W/kg; SAR(10 g) = 0.244 W/kg Maximum value of SAR (measured) = 0.646 W/kg Date: 2024/8/14 LTE B5 Head Communication System: UID 0, LTE (0); Communication System Band: Band 5; Frequency: 836.5 MHz; Medium parameters used (interpolated): f = 836.5 MHz; = 0.885 S/m; r = 40.599; = 1000 kg/m3 Phantom section: Right Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.160 W/kg Configuration/Head/Zoom Scan (8x8x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.667 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 0.346 W/kg SAR(1 g) = 0.136 W/kg; SAR(10 g) = 0.097 W/kg Maximum value of SAR (measured) = 0.171 W/kg Date: 2024/8/26 LTE B5 Body Communication System: UID 0, LTE (0); Communication System Band: Band 5; Frequency: 836.5 MHz; Medium parameters used (interpolated): f = 836.5 MHz; = 0.888 S/m; r = 41.099; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (10x15x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.459 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 14.39 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.581 W/kg SAR(1 g) = 0.312 W/kg; SAR(10 g) = 0.179 W/kg Maximum value of SAR (measured) = 0.471 W/kg Date: 2024/8/14 LTE B12 Head Communication System: UID 0, LTE (0); Communication System Band: Band 12; Frequency: 707.5 MHz; Medium parameters used (interpolated): f = 707.5 MHz; = 0.882 S/m; r = 41.81; = 1000 kg/m3 Phantom section: Right Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.45, 10.45, 10.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.162 W/kg Configuration/Head/Zoom Scan (8x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.033 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.181 W/kg SAR(1 g) = 0.134 W/kg; SAR(10 g) = 0.101 W/kg Maximum value of SAR (measured) = 0.164 W/kg Date: 2024/8/26 LTE B12 Body Communication System: UID 0, LTE (0); Communication System Band: Band 12; Frequency: 707.5 MHz; Medium parameters used (interpolated): f = 707.5 MHz; = 0.884 S/m; r = 42.31; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.45, 10.45, 10.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (10x15x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.398 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 21.58 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 0.429 W/kg SAR(1 g) = 0.321 W/kg; SAR(10 g) = 0.250 W/kg Maximum value of SAR (measured) = 0.390 W/kg Date: 2024/8/12 LTE B25 Head Communication System: UID 0, LTE (0); Communication System Band: Band 25; Frequency: 1905 MHz; Medium parameters used: f = 1905 MHz; = 1.391 S/m; r = 38.519; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.124 W/kg Configuration/Head/Zoom Scan (7x8x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 2.334 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.158 W/kg SAR(1 g) = 0.094 W/kg; SAR(10 g) = 0.056 W/kg Maximum value of SAR (measured) = 0.135 W/kg Date: 2024/8/29 LTE B25 Body Communication System: UID 0, LTE (0); Communication System Band: Band 25; Frequency: 1905 MHz; Medium parameters used: f = 1905 MHz; = 1.404 S/m; r = 39.432; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.45, 8.45, 8.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.13 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 29.37 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 1.60 W/kg SAR(1 g) = 0.888 W/kg; SAR(10 g) = 0.476 W/kg Maximum value of SAR (measured) = 1.34 W/kg Date: 2024/8/14 LTE B26 Head Communication System: UID 0, LTE (0); Communication System Band: Band 26; Frequency: 831.5 MHz; Medium parameters used (interpolated): f = 831.5 MHz; = 0.886 S/m; r = 40.575; = 1000 kg/m3 Phantom section: Right Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.178 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.921 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 0.192 W/kg SAR(1 g) = 0.137 W/kg; SAR(10 g) = 0.101 W/kg Maximum value of SAR (measured) = 0.172 W/kg Date: 2024/8/26 LTE B26 Body Communication System: UID 0, LTE (0); Communication System Band: Band 26; Frequency: 831.5 MHz; Medium parameters used (interpolated): f = 831.5 MHz; = 0.888 S/m; r = 41.075; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.05, 10.05, 10.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.350 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 17.98 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.711 W/kg SAR(1 g) = 0.345 W/kg; SAR(10 g) = 0.177 W/kg Maximum value of SAR (measured) = 0.553 W/kg Date: 2024/8/26 LTE B41 Body Communication System: UID 0, TDD-LTE (0); Communication System Band: Band 41; Frequency: 2593 MHz; Medium parameters used (interpolated): f = 2593 MHz; = 1.863 S/m; r = 37.641; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(7.72, 7.72, 7.72); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.270 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.040 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.563 W/kg SAR(1 g) = 0.249 W/kg; SAR(10 g) = 0.103 W/kg Maximum value of SAR (measured) = 0.442 W/kg Date: 2024/8/12 LTE B66 Head Communication System: UID 0, LTE (0); Communication System Band: Band 66; Frequency: 1720 MHz; Medium parameters used: f = 1720 MHz; = 1.398 S/m; r = 39.092; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.76, 8.76, 8.76); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.159 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.183 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 0.186 W/kg SAR(1 g) = 0.128 W/kg; SAR(10 g) = 0.083 W/kg Maximum value of SAR (measured) = 0.168 W/kg Date: 2024/8/26 LTE B66 Body Communication System: UID 0, LTE (0); Communication System Band: Band 66; Frequency: 1720 MHz; Medium parameters used: f = 1720 MHz; = 1.403 S/m; r = 39.592; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(8.76, 8.76, 8.76); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.455 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.11 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 0.713 W/kg SAR(1 g) = 0.436 W/kg; SAR(10 g) = 0.237 W/kg Maximum value of SAR (measured) = 0.613 W/kg Date: 2024/8/14 LTE B71 Head Communication System: UID 0, LTE (0); Communication System Band: Band 71; Frequency: 673 MHz; Medium parameters used (interpolated): f = 673 MHz; = 0.874 S/m; r = 41.87; = 1000 kg/m3 Phantom section: Right Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.45, 10.45, 10.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.115 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.447 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.129 W/kg SAR(1 g) = 0.095 W/kg; SAR(10 g) = 0.072 W/kg Maximum value of SAR (measured) = 0.117 W/kg Date: 2024/8/26 LTE B71 Body Communication System: UID 0, LTE (0); Communication System Band: Band 71; Frequency: 673 MHz; Medium parameters used (interpolated): f = 673 MHz; = 0.876 S/m; r = 42.37; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(10.45, 10.45, 10.45); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (10x15x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.305 W/kg Configuration/Body/Zoom Scan (5x5x4)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 19.21 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.335 W/kg SAR(1 g) = 0.250 W/kg; SAR(10 g) = 0.196 W/kg Maximum value of SAR (measured) = 0.304 W/kg Date: 2024/8/29 2.4G WIFI Head Communication System: UID 0, 2.45GHz Wi-Fi (0); Communication System Band: ISM 2.4GHz; Frequency: 2462 MHz; Medium parameters used (interpolated): f = 2462 MHz; = 1.766 S/m; r = 38.282; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(7.98, 7.98, 7.98); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.988 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 11.82 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 1.70 W/kg SAR(1 g) = 0.620 W/kg; SAR(10 g) = 0.223 W/kg Maximum value of SAR (measured) = 1.18 W/kg Date: 2024/8/29 2.4G WIFI Body Communication System: UID 0, 2.45GHz Wi-Fi (0); Communication System Band: ISM 2.4GHz; Frequency: 2462 MHz; Medium parameters used (interpolated): f = 2462 MHz; = 1.766 S/m; r = 38.282; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(7.98, 7.98, 7.98); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.250 W/kg Configuration/Body/Zoom Scan (7x9x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 10.26 V/m; Power Drift = -0.13 dB Peak SAR (extrapolated) = 0.354 W/kg SAR(1 g) = 0.168 W/kg; SAR(10 g) = 0.077 W/kg Maximum value of SAR (measured) = 0.285 W/kg Date: 2024/8/28 U-NII-1 Body Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5180 MHz; Medium parameters used: f = 5180 MHz; = 4.496 S/m; r = 34.77; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.64, 5.64, 5.64); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x13x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.252 W/kg Configuration/Body/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 4.346 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.427 W/kg SAR(1 g) = 0.121 W/kg; SAR(10 g) = 0.040 W/kg Maximum value of SAR (measured) = 0.274 W/kg Date: 2024/8/28 U-NII-2A Head Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5320 MHz; Medium parameters used: f = 5320 MHz; = 4.627 S/m; r = 34.554; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.64, 5.64, 5.64); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Left Tilt/Head/Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.815 W/kg Left Tilt/Head/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 9.550 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 1.79 W/kg SAR(1 g) = 0.368 W/kg; SAR(10 g) = 0.099 W/kg Maximum value of SAR (measured) = 1.02 W/kg Date: 2024/8/28 U-NII-2A Body Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5320 MHz; Medium parameters used: f = 5320 MHz; = 4.627 S/m; r = 34.554; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.64, 5.64, 5.64); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.206 W/kg Configuration/Body/Zoom Scan (10x9x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0.6310 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 0.382 W/kg SAR(1 g) = 0.085 W/kg; SAR(10 g) = 0.028 W/kg Maximum value of SAR (measured) = 0.216 W/kg Date: 2024/8/28 U-NII-2A Limb Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5320 MHz; Medium parameters used: f = 5320 MHz; = 4.627 S/m; r = 34.554; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.64, 5.64, 5.64); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x13x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 4.73 W/kg Configuration/Body/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 5.304 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 28.9 W/kg SAR(1 g) = 4.56 W/kg; SAR(10 g) = 0.926 W/kg Maximum value of SAR (measured) = 12.2 W/kg Date: 2024/8/29 U-NII-2C Head Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5700 MHz; Medium parameters used: f = 5700 MHz; = 4.985 S/m; r = 35.291; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.01, 5.01, 5.01); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Left Tilt/Head/Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.605 W/kg Left Tilt/Head/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 6.380 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 1.40 W/kg SAR(1 g) = 0.265 W/kg; SAR(10 g) = 0.059 W/kg Maximum value of SAR (measured) = 0.822 W/kg Date: 2024/8/29 U-NII-2C Body Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5700 MHz; Medium parameters used: f = 5700 MHz; = 4.985 S/m; r = 35.291; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.01, 5.01, 5.01); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.0624 W/kg Configuration/Body/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.308 W/kg SAR(1 g) = 0.026 W/kg; SAR(10 g) = 0.00723 W/kg Maximum value of SAR (measured) = 0.0837 W/kg Date: 2024/8/29 U-NII-2C Limb Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5700 MHz; Medium parameters used: f = 5700 MHz; = 4.985 S/m; r = 35.291; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.01, 5.01, 5.01); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (7x13x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 2.07 W/kg Configuration/Body/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 2.912 V/m; Power Drift = -0.08 dB Peak SAR (extrapolated) = 11.4 W/kg SAR(1 g) = 1.7 W/kg; SAR(10 g) = 0.323 W/kg Maximum value of SAR (measured) = 5.45 W/kg Date: 2024/8/29 U-NII-3 Head Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5795 MHz; Medium parameters used: f = 5795 MHz; = 5.353 S/m; r = 33.956; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.05, 5.05, 5.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Left Tilt/Head/Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.838 W/kg Left Tilt/Head/Zoom Scan (8x8x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 5.980 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 4.05 W/kg SAR(1 g) = 0.385 W/kg; SAR(10 g) = 0.089 W/kg Maximum value of SAR (measured) = 1.13 W/kg Date: 2024/8/29 U-NII-3 Body Communication System: UID 0, 5GHz Wi-Fi (0); Communication System Band: 5G Band(5030.0 - 5825.0 MHz); Frequency: 5795 MHz; Medium parameters used: f = 5795 MHz; = 5.353 S/m; r = 33.956; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(5.05, 5.05, 5.05); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 29.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (13x22x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.177 W/kg Configuration/Body/Zoom Scan (9x9x6)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 0 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 0.346 W/kg SAR(1 g) = 0.075 W/kg; SAR(10 g) = 0.023 W/kg Maximum value of SAR (measured) = 0.224 W/kg Date: 2024/8/29 BT Head Communication System: UID 0, BT(0) (0); Communication System Band: BT; Frequency: 2402 MHz; Medium parameters used (interpolated): f = 2402 MHz; = 1.71 S/m; r = 38.276; = 1000 kg/m3 Phantom section: Left Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(7.98, 7.98, 7.98); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Head/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.173 W/kg Configuration/Head/Zoom Scan (7x7x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.005 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.260 W/kg SAR(1 g) = 0.093 W/kg; SAR(10 g) = 0.033 W/kg Maximum value of SAR (measured) = 0.164 W/kg Date: 2024/8/29 BT Body Communication System: UID 0, BT(0) (0); Communication System Band: BT; Frequency: 2402 MHz; Medium parameters used (interpolated): f = 2402 MHz; = 1.71 S/m; r = 38.276; = 1000 kg/m3 Phantom section: Flat Section DASY Configuration: · Probe: EX3DV4 - SN7733; ConvF(7.98, 7.98, 7.98); Calibrated: 2024/2/21; · Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = -9.0, 31.0 · Electronics: DAE4 Sn1739; Calibrated: 2024/1/23 · Phantom: SAM; Type: QD000P40CD; Serial: 1805 · DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331) Configuration/Body/Area Scan (11x18x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 0.0190 W/kg Configuration/Body/Zoom Scan (8x8x4)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 0.6710 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.0450 W/kg SAR(1 g) = 0.014 W/kg; SAR(10 g) = 0.00621 W/kg Maximum value of SAR (measured) = 0.0220 W/kg
Related FCC IDs:
- 2ADINS6603L - Sun Cupid Technology (HK) Ltd. LTE Smart Phone [S6603L] Microsoft Word for Microsoft 365