TR3768 165 BLE

Adam Hauke

Test Report BLE

Ezurio LLC SONANX611M SQG-SONANX611M SQGSONANX611M sonanx611m

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 32 Pages, 3.96MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7712540
A

Test Report TR3768-165-BLE

Equipment Under Test: Module, SONA NX 611 M.2 2230, 2 MHF

Requirement(s):

eCFR 47 Part 15.247 | RSS-247

Test Date(s):

01/22/2024-04/30/2024

Prepared for:

Ezurio Attn: Brian Petted W66 N220 Commerce Ct. Cedarburg, WI 53012

Report Issued by: Adam Hauke, EMC Engineer Signature:
Report Reviewed by: Adam Alger, Manager EMC Laboratory Signature:
Report Constructed by: Adam Hauke, EMC Engineer Signature:

Date: 08/08/2024 Date: 8/07/2024 Date: 08/08/2024

This test report may not be reproduced, except in full, without approval of Ezurio

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 1 of 32

Name:Module, SONA NX611 M.2 2230, 2 MHF Model:Sona NX611M
Serial:00047

CONTENTS
Contents........................................................................................................................................................ 2 Ezurio Test Services in Review .................................................................................................................. 3
1 Test Report Summary ........................................................................................................................... 4 2 Client Information................................................................................................................................. 5
2.1 Equipment Under Test (EUT) Information................................................................................... 5 2.2 Product Description..................................................................................................................... 5 2.3 Modifications Incorporated for Compliance ............................................................................... 5 2.4 Deviations and Exclusions from Test Specifications.................................................................... 5 2.5 EUT Information .......................................................................................................................... 5 2.6 Ancillary Equipment .................................................................................................................... 6 2.7 Antenna Information ................................................................................................................... 6 2.8 Test Channels............................................................................................................................... 6 2.9 Power Table and Reduced Video Bandwidth for Average Measurements ................................. 6 3 Worst Case Test Results Summary........................................................................................................ 7 4 References ............................................................................................................................................ 8 5 Uncertainty Summary ........................................................................................................................... 9 6 Test Data ............................................................................................................................................. 10 6.1 Antenna Port Conducted Emissions .......................................................................................... 10 6.2 Radiated Emissions .................................................................................................................... 24 6.3 AC Mains Conducted Emissions................................................................................................. 29 7 Revision History .................................................................................................................................. 32

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 2 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Ezurio Test Services in Review The Ezurio laboratory located at W66 N220 Commerce Court Cedarburg, Wisconsin, 53012 USA is recognized through the following organizations:
A2LA ­ American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025:2017 with Electrical (EMC) Scope A2LA Certificate Number: 1255.01 Scope of accreditation includes all test methods listed herein unless otherwise noted

Federal Communications Commission (FCC) ­ USA Accredited Test Firm Registration Number: 953492 Recognition of two 3 meter Semi-Anechoic Chambers

Innovation, Science and Economic Development Canada Accredited U.S. Identification Number: US0218 Recognition of two 3 meter Semi-Anechoic Chambers

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 3 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

1 TEST REPORT SUMMARY
During 01/22/2024-04/30/2024 the Equipment Under Test (EUT), Module, SONA NX611 M.2 2230, 2 MHF, as provided by Ezurio was tested to the following requirements:

FCC 15.247 | RSS-247 ­ DTS Bluetooth Low Energy

Requirements
15.247(d) 15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.10
15.247(a)(2) RSS-247 Clause 5.2 (a)
15.247(b)(3) RSS-247 Clause 5.4 (d) 15.247(d) RSS-247 Clause 5.5 RSS-GEN A1 Clause 8.9
15.247(e) RSS-247 Clause 5.2 (b) 2.1055(d) RSS-GEN 6.11
15.207 RSS-GEN 8.8

Description Spurious Radiated Emissions in
Restricted Bands 30-40000 MHz 6dB and 99% Occupied Bandwidth RF Output Power
Out-of-band Emissions
Power Spectral Density Frequency Stability
AC Conducted Emissions

Method

Compliant

ANSI C63.10

Yes

ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10

Yes Yes Yes Yes Reported Yes

Notice:
The results relate only to the item tested as configured and described in this report. Any additional configurations, modes of operation, or modifications made to the equipment under test after the specified test date(s) are at the decision of the client and may not apply to the data seen in this test report.
The decision rule for Pass / Fail assessment to the specification or standard listed in this test report has been agreed upon by the client and laboratory to be as follows:

Measurement Type Emissions ­ Amplitude Emissions ­ Frequency Immunity

Rule 1 dB below specified limit 1% less than the specification Tested at specified level

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 4 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

2 CLIENT INFORMATION

Company Name

Ezurio

Contact Person

Brian Petted

Address

W66 N220 Commerce Ct. Cedarburg, WI 53012

2.1 Equipment Under Test (EUT) Information The following information has been supplied by the client

Product Name

Module, SONA NX611 M.2 2230, 2 MHF

Part Number

453-00165

Serial Number

00047

FCC ID

SQG-SONANX611M

IC ID

3174A-SONANX611M

2.2 Product Description
The NX611 is based upon NXP IW611 Wi-Fi 6 chipset. Feature-set includes 802.11 a/b/g/n/ac/ax Wi-Fi 6 and Dual-Mode Bluetooth v5.3 (BDR + EDR + BLE).

2.3 Modifications Incorporated for Compliance None noted at time of test

2.4 Deviations and Exclusions from Test Specifications None noted at time of test

2.5 EUT Information

Power Supply ­ INPUT:100-240VAC 50/60 Hz 0.3A OUTPUT: 5VDC 2A

Firmware -

sduart_nw61x_v1.bin.se

Sduart_nw61x_v1_mfg.bin.se

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 5 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

2.6 Ancillary Equipment

Equipment used for EUT programming (not part of the EUT)

Development Kit, SU60-SOMC 6.0

P/N:

463-00138-K1 Rev 1

Power Supply: INPUT:

100-240 VAC 50/60Hz 0.7A

HP Elitebook 840G1

OUTPUT:

12VDC 2A

Labtool

Version: 1.0.0.45.6

2.7 Antenna Information

Peak Gain (dBi)

Manufacturer Model Part Number Dimension

Type 2400-2500 4900-5925

MHz MHz

Laird Connectivity

FlexMIMO EFD2471A3S- 39.5mm X 39.5mm

6E

10MH4L

X 4.7mm

PIFA

2.2

3.8

Laird Connectivity

FlexPIFA 6E

EFB2471A3S10MH4L

16mm X 36mm X 2.5mm

PIFA

2.2

3.9

Mini

Laid Connectivity NanoBlade

EMF2471A3S10MH4L

36mm X 12mm X 0.3mm

PCB Dipole

2.4

4.4

Flex 6E

Joymax Electronics

N/A TWX-100BRS3B 137mm X 13mm Dipole

2.0

4.0

Laird Connectivity

FlexPIFA

EFB2455A3S- 38.5mm X 12.7 mm

16MHF1

X 2.5mm

PIFA

2.5

3.0

2.8 Test Channels
Channel 0 19 39

Frequency (MHz) 2402 2440 2480

Data Rates 125k, 500k, 1M and 2M

2.9 Power Table and Reduced Video Bandwidth for Average Measurements

Data Rate
125 kbps 500 kbps 1 Mbps 2 Mbps

Minimum Average VBW (Hz) 1000 330 2700 5100

Power Setting
6 6 6 6

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 6 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

3 WORST CASE TEST RESULTS SUMMARY

Requirement

Channel and Data Rate

15.247 (a)(2) RSS-247 Clause 5.2(a)

0 | 500 kbps

15.247 (b)(3) RSS-247 Clause 5.4 (d)

0 | 1 Mbps

15.247 (e) RSS-247 Clause 5.2 (b)

0 | 125 kbps

15.247 (d)

0 | 1 Mbps

RSS-247 Clause 5.5 Conducted

39 | 2 Mbps

15.247(d)

RSS-247 Clause 5.5 RSS-GEN Clause 8.9

19 | 1 Mbps

Radiated

15.207

17 | 1 Mbps

Frequency (MHz)
2388.4 2483.5
44.0
0.517

Measurement
651 kHz 6.5 dBm

Limit
at least 500 kHz
30 dBm

Margin
23.5 dB

6.3 dBm/100 kHz 8.0 dBm/3 kHz

-39.4 dBm

-21.2 dBm

-52.6 dBm

-41.2 dBm

1.7 dB 18.2 dB 11.4 dB

38.2 dBµV/m 40.0 dBµV/m 1.8 dB

24.9 dBµV

46.0 dBµV

21.1 dB

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 7 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

4 REFERENCES
Publication FCC eCFR 47 Part 15 ANSI C63.10 RSS-247 RSS-GEN KDB 558074 D01

Edition 3 5 -

Date 2023 2020 2023 2018 2019

AMD 1 -
2019 -

AMD 2 -
2021 -

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 8 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

5 UNCERTAINTY SUMMARY
Using the guidance of the following publications the calculated measurement uncertainty represents an expanded uncertainty expressed at approximately the 95 % confidence level, using a coverage factor of k = 2.
References CISPR 16-4-1 CISPR 16-4-2 CISPR 32 ANSI C63.23 A2LA P103 A2LA P103c ETSI TR 100-028

Measurement Type Radiated Emissions Radiated Emissions Radiated Emissions AC Line Conducted Emissions Telecom Conducted Emissions Disturbance Power Emissions Radiated Immunity Conducted Immunity EFT Burst/Surge ESD Immunity

Configuration Biconical Antenna Log Periodic Antenna
Horn Antenna Artificial Mains Network Asymmetric Artificial Network
Absorbing Clamp 3 Volts/meter CDN/EM/BCI
Peak pulse voltage 15 kV level

Uncertainty ± 5.0 dB 5.3 dB 4.7 dB 3.4 dB 4.9 dB 4.1 dB 2.2 dB
2.4/3.5/3.4 dB 164 volts 1377 Volts

Parameter Radio Frequency, from F0 Occupied Channel Bandwidth RF conducted Power (Power Meter) RF conducted emissions (Spectrum Analyzer) All emissions, radiated Temperature Humidity Supply voltages

ETSI U.C. ± 1x10-7 5 % 1.5 dB 3.0 dB 6.0 dB 1° C 5 % 3 %

U.C. ± 0.55x10-7
2 % 1.2 dB 1.7 dB 5.3 dB 0.65° C 2.9 %
1 %

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 9 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6 TEST DATA

6.1 Antenna Port Conducted Emissions

Description of Measurement

The direct measurement of emissions at the antenna port of the EUT is achieved by use of a RF connection to a spectrum analyzer or power meter.
The cable and attenuator factors are loaded into the analyzer or power meter allowing for direct measurement readings without the need for further corrections.

Example Calculations

Measurement (dBm) + Cable factor (dB) + External Attenuator (dB) = Corrected Reading (dBm)
Margin (dB) = Limit (dBm) ­ Corrected Reading (dBm)

Block Diagram EUT

RF Cable

Ext. Atten
.

Spectrum Analyzer/
Power Meter

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 10 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.1.1 6dB and 99% Occupied Bandwidth

Operator

Dylan Rosenfeldt

Temperature 22.3°C

Test Date 03/15/2024

Requirement

15.247 (a)(2) RSS-247 Clause 5.2 (a)

QA R.H. % Location Method

Limits: The minimum 6 dB bandwidth shall be at least 500 kHz

Test Parameters

Frequency 2400-2483.5 MHz

RBW

99% OBW - 30 kHz 6dB DTS - 100 kHz

Detector(s) Peak

Setup VBW Settings

Adam Hauke 30.30% Conducted RF Bench ANSI C63.10 6.9
Antenna Port 300 kHz Max Hold

Instrumentation

Asset # AA 960173 EE 960085

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 388
MY51210148

Date 6/13/2023 4/27/2023

Due Date 6/12/2024 4/27/2024

Status Active Verification Active Calibration

EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

BLE Tx See 2.10

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 11 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Table

Rate 1 Mbps 2 Mbps 500 kbps 125 kbps

Channel 0 19 39 0 19 39 0 19 39 0 19 39

6 dB BW (MHz) 696 699 686 1170 1166 1170 651 656 652 683 673 671

99% BW (MHz) 1029 1039 1038 2066 2068 2069 1057 1059 1059 1022 1019 1020

Plots

Channel 0 | 500k | 6 dB DTS BW

Channel 19 | 125k | 99% OBW

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 12 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.1.2 RF Output Power

Operator

Dylan Rosenfeldt

Temperature 21.9°C-22.1°C

Test Date 03/12/2024 | 03/15/2024

Requirement

15.247 (b)(3) RSS-247 Clause 5.4 (d)

QA R.H. % Location Method

Adam Hauke 31.50%-33.30% Conducted RF Bench ANSI C63.10 11.9.1

Limit: The maximum peak conducted output power of the intentional radiator shall not exceed 1 Watt.

Test Parameters Frequency 2400-2483.5 MHz

RBW

3 MHz

Detector(s) Peak

Setup VBW Settings

Antenna Port
50 MHz Max Hold Span: 10 MHz

Instrumentation

Asset # AA 960173 EE 960088

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 388
MY51210138

Date 6/13/2023 4/10/2023

Due Date 6/12/2024 4/10/2024

Status Active Verification Active Calibration

EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

BLE Tx See 2.10

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 13 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Tables

Rate 1 Mbps 2 Mbps 500 kbps 125 kbps

Channel 0 19 39 0 19 39 0 19 39 0 19 39

Peak Output Power (dBm) 6.5 6.4 6.2 6.5 6.4 6.2 6.4 6.4 6.2 6.5 6.4 6.2

Limit (dBm) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0

Margin (dB) 23.5 23.6 23.8 23.5 23.6 23.8 23.6 23.6 23.8 23.5 23.6 23.8

Plots

Channel 0 | 1 Mbps

Channel 19 | 2 Mbps

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 14 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.1.3 Power Spectral Density

Operator

Dylan Rosenfeldt

Temperature 21.8°C

Test Date 03/13/2024

Requirement

15.247 (e) RSS-247 Clause 5.2 (b)

QA R.H. % Location Method

Adam Hauke 33.70% Conducted RF Bench ANSI C63.10 11.10.2

Limits: Power spectral density shall not be greater than 8 dBm in any 3 kHz band.

Test Parameters Frequency 2400-2483.5 MHz

Detector(s) Peak

RBW Notes

100 kHz

VBW

300 kHz

The same method of determining the conducted output power shall be used to determine the power spectral density

Instrumentation

Asset # AA 960173 EE 960088

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 388
MY51210138

Date 6/13/2023 4/10/2023

Due Date 6/12/2024 4/10/2024

Status Active Verification Active Calibration

EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

BLE Tx See 2.10

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 15 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Table

Rate 1 Mbps 2 Mbps 500 kbps 125 kbps

Channel 0 19 39 0 19 39 0 19 39 0 19 39

Peak PSD (dBm/100 kHz) 5.8 5.7 5.5 5.9 5.8 5.6 4.1 4.1 3.9 6.3 6.3 6.1

Limit (dBm/3 kHz) 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0

Margin (dB) 2.2 2.3 2.5 2.1 2.2 2.4 3.9 3.9 4.1 1.7 1.7 1.9

Plots

Channel 0 | 125 kbps

Channel 19 | 125 kbps

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 16 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.1.4 Out-of-band Emissions

Operator

Dylan Rosenfeldt

Temperature 21.3°C | 22.0°C

Test Date 03/18/2024 | 03/29/2024

Requirement

15.247(d) RSS-247 Clause 5.5

QA R.H. % Location Method

Adam Alger 23.00% | 24.60% Conducted RF Bench ANSI C63.10 11.12.2.5.2

Limits: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement provided the transmitter demonstrates compliance with the peak conducted power limits.

Reference Level (Worst Case PSD) Channel 0 ­ 125 kbps ­ 6.3 dBm/100 kHz 6.3 dBm-20 dB = -13.7 dBm Limit

Test Parameters Frequency 30-40000 MHz

Setup

Antenna Port

RBW

100 kHz

VBW

300 kHz

Detector(s) Peak and Average (RMS)

Notes
Example Calculations

Declared antenna gain for band edge ­ 2.5 dBi Correction Factor = 20 log (1/D), where D is the duty cycle

Instrumentation

Asset # AA 960172 EE 960085 EE 960087 AA 960173

Description
Cable
Analyzer ­ Spectrum Analyzer Spectrum
Cable

Manufacturer A.H. Systems,
Inc.
Agilent
Agilent
A.H. Systems, Inc.

Model # SAC-26G-1
N9010A N9010A SAC-26G-1

Serial # 387
MY53400296 MY53400296
388

Date 06/13/2023 04/11/2023 4/11/2023 6/13/2023

Due Date 06/12/2024 04/11/2024 4/11/2024 6/12/2024

Status Active Verification Active Calibration Active Calibration Active Verification

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 17 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

2.4 GHz WLAN Tx See 2.8

Measurements

Rate 1 Mbps 2 Mbps 500 kbps
125 kbps

Channel 0 0 0 0 39

Frequency (MHz) 2388.6 2400.0 2388.7 2388.5 27277.1

Measurement (dBm) -49.8 -25.9 -51.0 -50.0 -63.5

Limit (dBm) -13.7 -13.7 -13.7 -13.7 -13.7

Margin (dB) 36.1 12.2 37.3 36.3 49.8

Worst Case Plots

Channel 0 |125 kbps | Reference

Channel 0 | 2 Mbps | 30-2400 MHz

Channel 39| 125 kbps | 2500-40000 MHz

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 18 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.1.5 Spurious Emissions in Restricted Bands

Operator

Dylan Rosenfeldt

Temperature 21.7°C | 20.9°C

Test Date 03/08/2024 | 03/11/2024

Requirement

15.247(d) RSS-247 Clause 5.5

QA R.H. % Location Method

Adam Alger 34.40% | 24.90% Conducted RF Bench ANSI C63.10 11.12.2.5.2

15.209 Limits:
Frequency (MHz)
30-88 88-216 216-960 960-1000 1000-40000

Quasi-Peak Limit (dBµV/m) 40.0 43.5 46.0 54.0 -

Average Limit (dBµV/m) 54.0

Peak Limit (dBµV/m)
74.0

Test Parameters Frequency 30-40000 MHz

Setup

Antenna Port

RBW

1 MHz

VBW

3 MHz

Detector(s) Peak

Method

Terminated

Notes
Example Calculations

Declared antenna gain­ 2.5 dBi
Correction Factor = 20 log (1/D), where D is the duty cycle EIRP = Measurement + Antenna Gain + Correction Factor E-Field = EIRP ­ 20log3 + 104.8

Instrumentation

Asset # AA 960172 EE 960085 EE 960087 AA 960173

Description
Cable
Analyzer ­ Spectrum Analyzer Spectrum
Cable

Manufacturer A.H. Systems,
Inc.
Agilent
Agilent
A.H. Systems, Inc.

Model # SAC-26G-1
N9010A N9010A SAC-26G-1

Serial # 387
MY53400296 MY53400296
388

Date 06/13/2023 04/11/2023 4/11/2023 6/13/2023

Due Date 06/12/2024 04/11/2024 4/11/2024 6/12/2024

Status Active Verification Active Calibration Active Calibration Active Verification

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 19 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2402 MHz | 2440 MHz

Mode Channel

BLE Tx 0 | 19

Measurements ­ Lower Band Edge

Rate
1 Mbps
2 Mbps 500 kbps 125 kbps

Channel
0 0 0 0 0 0 0 0

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz) 2388.4 2385.1 2388.3 2384.9 2388.7 2385.0 2388.4 2385.0

Measurement (dBm) -41.9 -62.8 -42.0 -63.7 -42.3 -63.3 -42.2 -63.1

EIRP (dBm) -39.4 -60.3 -39.5 -61.2 -39.8 -60.8 -39.7 -60.6

E-Field (dBµV/m)
55.9 35.0 55.8 34.1 55.5 34.5 55.6 34.7

Limit (dBµV/m)
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 18.1 19.0 18.2 19.9 18.5 19.5 18.4 19.3

Measurements ­ Upper Band Edge

Rate
1 Mbps
2 Mbps 500 kbps 125 kbps

Channel
39 39 39 39 39 39 39 39

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz) 2484.9 2483.5 2483.6 2483.5 2485.2 2483.5 2485.0 2483.5

Measurement (dBm) -39.0 -61.2 -39.1 -55.1 -39.7 -61.6 -40.2 -61.8

EIRP (dBm) -36.5 -58.7 -36.6 -52.6 -37.2 -59.1 -37.7 -59.3

E-Field (dBµV/m)
58.8 36.6 58.7 42.7 58.1 36.2 57.6 36.0

Limit (dBµV/m)
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 15.2 17.4 15.3 11.3 15.9 17.8 16.4 18.0

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 20 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Band Edge Worst Case Plots

Channel 0 | 1 Mbps | Peak

Channel 0 | 1 Mbps | Average

Channel 39 | 2 Mbps | Peak

Channel 39 | 2 Mbps | Average

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 21 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Spurious Table

Rate
1 Mbps 2 Mbps 500 kbps 125 kbps

Channel
0 0 0 0 0 0 19 19

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz)
2241.9 2281.7 2241.3 2281.3 2241.8 2294.5 2241.9 2281.6

Measurement (dBm)
-50.7 -68.3 -51.9 -68.3 -51.5 -69.8 -51.8 -69.1

EIRP (dBm)
-48.2 -65.8 -49.4 -65.8 -49.0 -67.3 -49.3 -66.6

E-Field (dBµV/m)
47.1 29.5 45.9 29.5 46.3 28.0 46.0 28.7

Limit (dBµV/m)
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB)
26.9 24.5 28.1 24.5 27.7 26.0 28.0 25.3

Spurious Worst Case Plots

Channel 19 | 2 Mbps | 30-1000 MHz

Channel 0 | 1 Mbps | 1000-2310 MHz

Channel 39 | 2 Mbps | 2500-4000 MHz

Channel 0 | 1 Mbps | 4000-40000 MHz

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 22 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.1.6 Frequency Stability

Operator

Dylan Rosenfeldt

Temperature 21.6°C

Test Date 04/25/2024

Requirement

15.407(g) RSS-GEN Clause 6.11

Test Parameters Frequency 2402-2480 MHz Detector(s) Peak

QA R.H. % Location Method

Anthony Smith 30.00% Conducted RF Bench ANSI C63.10 6.8

Voltage Settings

4.3 VDC, 5 VDC, and 5.8 VDC Max Hold

Instrumentation

Asset # AA 960173 EE 960088

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 387
MY51210138

Date 06/13/2023 4/10/2023

Due Date 06/12/2024 4/10/2024

Status Active Verification Active Calibration

Table
Channel 0 19 39

Voltage (VDC)
5 4.3 5.8 5 4.3 5.8 5 4.3 5.8

Center Frequency (Hz)
2402000851 2402000810 2402000778 2439999709 2439999658 2439999602 2480001126 2480000919 2480000395

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 23 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.2 Radiated Emissions

The frequency spectrum is investigated for intentional and / or unintentional signals emanating from the EUT by use of a standardized test site and measurement antenna.

Description of Measurement

The antenna, cable, pre-amp, and other necessary measurement system correction factors are loaded onto the EMI receiver / spectrum analyzer when the measurements are performed allowing the data to be gathered and reported as corrected values.

The maximum emissions from the EUT are determined by turn-table azimuth rotation (360°) and scanning of the measurement antenna. Maximized levels are noted at degree values of azimuth, measurement antenna height, and measurement antenna polarity.

Measurement (dBµV) + Cable factor (dB) + Other (dB) + Antenna Factor (dB/m) = Corrected Reading (dBµV/m)

Example Calculations

Margin (dB) = Limit (dBµV/m) - Corrected Reading (dBµV/m)
Example at 4000 MHz: Reading = 40 dBµV + 3.4 dB + 0.9 dB + 6.5 dB/m = 50.8 dBµV/m Average Limit = 20 log (500) = 54 dBµV/m Margin = 54 dBµV/m - 50.8 dBµV/m = 3.2 dB

Block Diagram

EMI

Receiver / Spectrum

Antenna

EUT

Analyzer

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 24 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.2.1 Spurious Radiated Emissions in the Restricted Bands

Operator

Mitchell Freund | Nicole Sedmak Jon Dilley | Zachary Brown

Temperature 23.4°C-24.0°C

QA R.H. %

Anthony Smith | Adam Alger Adam Hauke | Dylan Rosenfeldt
19.90%-32.40%

Test Date Requirement

03/14/2024-03/21/2024
15.247 (d) | 15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.9

Location Method

Chamber 3 | Chamber 5 ANSI C63.10

15.209 Limits:
Frequency (MHz)
30-88 88-216 216-960 960-1000 1000-40000

Quasi-Peak Limit (dBµV/m) 40.0 43.5 46.0 54.0 -

Average Limit (dBµV/m) 54.0

Peak Limit (dBµV/m)
74.0

Test Parameters

Frequency Detector(s) RBW

30-40000 MHz
Peak Trace Peak and Average Final <1000 MHz ­ 120 kHz >1000 ­ 1 MHz

Distance

3 m

Table height VBW

150 cm
<1000 ­ 1.2 MHz >1000 ­ See 2.9

Instrumentation

Asset # AA 960007
AA 960081 AA 960154 AA 960163 AA 960217 AA 960221 EE 960085

Description Antenna Double Ridge
Horn Antenna Double Ridge
Horn Filter - High Pass 2.4 GHz Antenna - Log
Periodic Antenna Biconical
Cable
Analyzer EMI Receiver

Manufacturer
EMCO
EMCO
KWM A.H. Systems,
Inc. A.H. Systems,
Inc. A.H. Systems,
Inc. Agilent

Model # 3115
3115 HPF-L-14186
SAS-512-2 SAS-540 SAC-26G-6 N9038A

Serial # 9311-4138
6907 7272-02
500 852 524 MY51210148

Date 8/10/2023
1/11/2024 4/11/2023 8/10/2023 7/17/2023 6/13/2023 4/27/2023

Due Date 8/10/2024
1/11/2025 4/11/2024 8/10/2024 7/17/2024 6/13/2024 4/27/2024

Status
Active Calibration
Active Calibration
Active Calibration
Active Calibration
Active Calibration
Active Verification
Active Calibration

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 25 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

EE 960203 LSC-300 LSC-500

Analyzer EMI Receiver
Cable
Cable

Keysight
Chamber 3 Emissions Chamber 5 Emissions

N9038A -

MY56400072 -

4/11/2023 1/5/2024 1/8/2024

4/11/2024 1/5/2025 1/8/2025

Active Calibration
Active Verification
Active Verification

EUT Parameters

Input Power EUT Notes

120 VAC @ 60 Hz

Mode

BLE Tx

X, Y, Z Plane Orientations Antenna ports terminated with AE 50  SMA terminators

HP Elitebook 840G1 Ezurio ­ SOM60 Development Kit

6000 MHz Emission from auxiliary equipment. Not a function of the EUT.

Radiated Spurious ­ 30-1000 MHz ­ Channel 19 ­ 1 Mbps

Frequency (MHz)
44.0 44.0 78.0 125.0 220.0 308.0 375.0 396.3 479.9

Antenna Polarity
V H V V H V H H V

Height (cm)
103 276 140 159 164 175 308 125 135

Azimuth (degree)
256 247 55 261 329 162 341 327 17

Quasi-Peak Reading (dBµV/m) 30.7 38.2 34.3 37.0 36.6 40.3 39.9 38.7 40.4

Quasi-Peak Limit
(dBµV/m) 40.0 40.0 40.0 43.5 46.0 46.0 46.0 46.0 46.0

Margin (dB)
9.3 1.8 5.7 6.5 9.4 5.7 6.7 7.3 5.6

*The spurious signals detected do not depend on either the operating channel or the modulation mode

1000-40000 MHz

Band Edge

Channel

EUT Orientation

0

X Plane

39

Z Plane

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Data Rate 125 kbps 500 kbps 1 Mbps 2 Mbps 125 kbps 500 kbps

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz) 2342.0 2348.3 2325.2 2384.9 2365.7 2349.5 2388.4 2387.9 2487.1 2491.6 2484.0 2486.0

Page 26 of 32

Antenna Polarity
H H H H H H H H H H H H

Measurement (dBµV/m) 52.2 41.0 52.4 40.3 52.0 41.6 51.8 42.3 51.8 40.9 52.0 40.4

Limit (dBµV/m)
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB) 16.0 13.0 15.8 13.7 16.2 12.4 16.4 11.7 16.4 13.1 16.2 13.6

Name: Module, SONA NX611 M.2 2230, 2 MHF

Model: SONA NX611M

Serial: 00047

1 Mbps

Peak Average

2492.9 2487.0

H H

2 Mbps

Peak Average

2487.9 2484.5

H H

Spurious No Emissions Present

Worst Case Plots

53.4

74.0

14.8

41.6

54.0

12.4

52.3

74.0

15.9

42.3

54.0

11.7

Channel 19 | 1 Mbps 30-200 MHz | Vertical

Channel 0 | 1 Mbps 200-1000 MHz | Vertical

Channel 0 | 125 kbps 1000-2310 MHz | Horizontal

Channel 0 | 125 kbps 2500-4000 MHz | Vertical

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 27 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Channel 0 | 1 Mbps 4000-18000 MHz | Vertical

Channel 19 | 1 Mbps 18000-40000 MHz | Vertical

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 28 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.3 AC Mains Conducted Emissions

A line impedance stabilization network (LISN) or artificial mains network (AMN) allows the emissions of the power supply conductors to be measured while isolating the EUT from the supply mains.

The AMN, cable, and other necessary measurement system correction factors are

Description of Measurement

loaded onto the EMI receiver when the measurements are performed. The data is

gathered and reported as the corrected values.

Maximum emissions are determined with a peak max hold trace then measurements at a selection of the highest points are made with quasi-peak and average detectors. Results are recorded and compared to limit for each line. (e.g. line and neutral)

Example Calculations

Measurement (dBµV) + Cable factor (dB) + Other (dB) = Corrected Reading (dBµV) Margin (dB) = Limit (dBµV) - Corrected Reading (dBµV)

Block Diagram

EUT

AMN

Cable

EMI Receiver

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 29 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

6.3.1 AC Mains Conducted Emissions

Operator

Jon Dilley

Temperature 20.8°C

Test Date 1/22/2024

Requirement 15.207

QA R.H. % Location Method

Adam Hauke 19.60% AC Conducted Bench ANSI C63.10

Limits:

Frequency (MHz)

Quasi-Peak Limit (dBµV)

0.15-0.5

66.0-56.0*

0.5-5

56.0

5-30

60.0

*Decreases with the logarithm of the frequency.

Average Limit (dBµV) 56.0-46.0* 46.0 50.0

Test Parameters

Frequency Detector(s) RBW Notes

0.15-30 MHz

Distance

Peak Trace Quasi-Peak, Average Final
9 kHz

Table height VBW

Channel has no effect on emission

40 cm from wall 80 cm from LISN 80 cm
62 kHz

Instrumentation

Asset # EE 960088 EE 960089

Description Analyzer - EMI
Receiver
LISN

Manufacturer Agilent
COM-POWER

Model # N9038A LI-215A

Serial # MY51210148
191943

EE 960162 LSC-212

LISN Cable

COM-POWER Micro-Coax

LI-215A
UFB311A-01440-70U70U

191969
64639 224071001

Date 4/27/2023 4/10/2023 4/10/2023 1/8/2024

Due Date 4/27/2024 4/10/2024 4/10/2024 1/8/2025

Status Active Calibration Active Calibration Active Calibration Active Verification

EUT Parameters Input Power 120 VAC @ 60 Hz

Mode

BLE Tx Channel 17 1 Mbps

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 30 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

Measurements

Line

Frequency (MHz)

1

0.159

1

0.517

1

11.870

2

0.155

2

0.530

2

11.780

Quasi Peak Reading (dBµV) 38.3 30.7 35.6 39.0 29.2 28.4

QuasiPeak Limit
(dBµV)
65.5 56.0 60.0 65.8 56.0 60.0

Quasi Peak Margin (dB) 27.2 25.3 24.4 26.8 26.8 31.6

Plots

Average Reading (dBµV)
29.2 24.9 24.9 29.7 22.2 14.3

Average Limit (dBµV)
55.5 46.0 50.0 55.8 46.0 50.0

Average Margin
(dB)
26.3 21.1 25.1 26.1 23.9 35.7

Line 1

Line 2

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 31 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047

7 REVISION HISTORY

Version 0.0 1.0

Date 08/05/2024 08/08/2024

Notes Initial Draft Final Draft

END OF REPORT

Person Adam Hauke Adam Hauke

Company: Ezurio
Report: TR3768-165-BLE Job: C-3768

Page 32 of 32

Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M
Serial: 00047



Related FCC IDs:

Search Any Device: