TR3768 165 BLE
Adam Hauke
Test Report BLE
Ezurio LLC SONANX611M SQG-SONANX611M SQGSONANX611M sonanx611m
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 32 Pages, 3.96MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7712540A Test Report TR3768-165-BLE Equipment Under Test: Module, SONA NX 611 M.2 2230, 2 MHF Requirement(s): eCFR 47 Part 15.247 | RSS-247 Test Date(s): 01/22/2024-04/30/2024 Prepared for: Ezurio Attn: Brian Petted W66 N220 Commerce Ct. Cedarburg, WI 53012 Report Issued by: Adam Hauke, EMC Engineer Signature: Report Reviewed by: Adam Alger, Manager EMC Laboratory Signature: Report Constructed by: Adam Hauke, EMC Engineer Signature: Date: 08/08/2024 Date: 8/07/2024 Date: 08/08/2024 This test report may not be reproduced, except in full, without approval of Ezurio Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 1 of 32 Name:Module, SONA NX611 M.2 2230, 2 MHF Model:Sona NX611M Serial:00047 CONTENTS Contents........................................................................................................................................................ 2 Ezurio Test Services in Review .................................................................................................................. 3 1 Test Report Summary ........................................................................................................................... 4 2 Client Information................................................................................................................................. 5 2.1 Equipment Under Test (EUT) Information................................................................................... 5 2.2 Product Description..................................................................................................................... 5 2.3 Modifications Incorporated for Compliance ............................................................................... 5 2.4 Deviations and Exclusions from Test Specifications.................................................................... 5 2.5 EUT Information .......................................................................................................................... 5 2.6 Ancillary Equipment .................................................................................................................... 6 2.7 Antenna Information ................................................................................................................... 6 2.8 Test Channels............................................................................................................................... 6 2.9 Power Table and Reduced Video Bandwidth for Average Measurements ................................. 6 3 Worst Case Test Results Summary........................................................................................................ 7 4 References ............................................................................................................................................ 8 5 Uncertainty Summary ........................................................................................................................... 9 6 Test Data ............................................................................................................................................. 10 6.1 Antenna Port Conducted Emissions .......................................................................................... 10 6.2 Radiated Emissions .................................................................................................................... 24 6.3 AC Mains Conducted Emissions................................................................................................. 29 7 Revision History .................................................................................................................................. 32 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 2 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Ezurio Test Services in Review The Ezurio laboratory located at W66 N220 Commerce Court Cedarburg, Wisconsin, 53012 USA is recognized through the following organizations: A2LA American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025:2017 with Electrical (EMC) Scope A2LA Certificate Number: 1255.01 Scope of accreditation includes all test methods listed herein unless otherwise noted Federal Communications Commission (FCC) USA Accredited Test Firm Registration Number: 953492 Recognition of two 3 meter Semi-Anechoic Chambers Innovation, Science and Economic Development Canada Accredited U.S. Identification Number: US0218 Recognition of two 3 meter Semi-Anechoic Chambers Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 3 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 1 TEST REPORT SUMMARY During 01/22/2024-04/30/2024 the Equipment Under Test (EUT), Module, SONA NX611 M.2 2230, 2 MHF, as provided by Ezurio was tested to the following requirements: FCC 15.247 | RSS-247 DTS Bluetooth Low Energy Requirements 15.247(d) 15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.10 15.247(a)(2) RSS-247 Clause 5.2 (a) 15.247(b)(3) RSS-247 Clause 5.4 (d) 15.247(d) RSS-247 Clause 5.5 RSS-GEN A1 Clause 8.9 15.247(e) RSS-247 Clause 5.2 (b) 2.1055(d) RSS-GEN 6.11 15.207 RSS-GEN 8.8 Description Spurious Radiated Emissions in Restricted Bands 30-40000 MHz 6dB and 99% Occupied Bandwidth RF Output Power Out-of-band Emissions Power Spectral Density Frequency Stability AC Conducted Emissions Method Compliant ANSI C63.10 Yes ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 Yes Yes Yes Yes Reported Yes Notice: The results relate only to the item tested as configured and described in this report. Any additional configurations, modes of operation, or modifications made to the equipment under test after the specified test date(s) are at the decision of the client and may not apply to the data seen in this test report. The decision rule for Pass / Fail assessment to the specification or standard listed in this test report has been agreed upon by the client and laboratory to be as follows: Measurement Type Emissions Amplitude Emissions Frequency Immunity Rule 1 dB below specified limit 1% less than the specification Tested at specified level Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 4 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 2 CLIENT INFORMATION Company Name Ezurio Contact Person Brian Petted Address W66 N220 Commerce Ct. Cedarburg, WI 53012 2.1 Equipment Under Test (EUT) Information The following information has been supplied by the client Product Name Module, SONA NX611 M.2 2230, 2 MHF Part Number 453-00165 Serial Number 00047 FCC ID SQG-SONANX611M IC ID 3174A-SONANX611M 2.2 Product Description The NX611 is based upon NXP IW611 Wi-Fi 6 chipset. Feature-set includes 802.11 a/b/g/n/ac/ax Wi-Fi 6 and Dual-Mode Bluetooth v5.3 (BDR + EDR + BLE). 2.3 Modifications Incorporated for Compliance None noted at time of test 2.4 Deviations and Exclusions from Test Specifications None noted at time of test 2.5 EUT Information Power Supply INPUT:100-240VAC 50/60 Hz 0.3A OUTPUT: 5VDC 2A Firmware - sduart_nw61x_v1.bin.se Sduart_nw61x_v1_mfg.bin.se Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 5 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 2.6 Ancillary Equipment Equipment used for EUT programming (not part of the EUT) Development Kit, SU60-SOMC 6.0 P/N: 463-00138-K1 Rev 1 Power Supply: INPUT: 100-240 VAC 50/60Hz 0.7A HP Elitebook 840G1 OUTPUT: 12VDC 2A Labtool Version: 1.0.0.45.6 2.7 Antenna Information Peak Gain (dBi) Manufacturer Model Part Number Dimension Type 2400-2500 4900-5925 MHz MHz Laird Connectivity FlexMIMO EFD2471A3S- 39.5mm X 39.5mm 6E 10MH4L X 4.7mm PIFA 2.2 3.8 Laird Connectivity FlexPIFA 6E EFB2471A3S10MH4L 16mm X 36mm X 2.5mm PIFA 2.2 3.9 Mini Laid Connectivity NanoBlade EMF2471A3S10MH4L 36mm X 12mm X 0.3mm PCB Dipole 2.4 4.4 Flex 6E Joymax Electronics N/A TWX-100BRS3B 137mm X 13mm Dipole 2.0 4.0 Laird Connectivity FlexPIFA EFB2455A3S- 38.5mm X 12.7 mm 16MHF1 X 2.5mm PIFA 2.5 3.0 2.8 Test Channels Channel 0 19 39 Frequency (MHz) 2402 2440 2480 Data Rates 125k, 500k, 1M and 2M 2.9 Power Table and Reduced Video Bandwidth for Average Measurements Data Rate 125 kbps 500 kbps 1 Mbps 2 Mbps Minimum Average VBW (Hz) 1000 330 2700 5100 Power Setting 6 6 6 6 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 6 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 3 WORST CASE TEST RESULTS SUMMARY Requirement Channel and Data Rate 15.247 (a)(2) RSS-247 Clause 5.2(a) 0 | 500 kbps 15.247 (b)(3) RSS-247 Clause 5.4 (d) 0 | 1 Mbps 15.247 (e) RSS-247 Clause 5.2 (b) 0 | 125 kbps 15.247 (d) 0 | 1 Mbps RSS-247 Clause 5.5 Conducted 39 | 2 Mbps 15.247(d) RSS-247 Clause 5.5 RSS-GEN Clause 8.9 19 | 1 Mbps Radiated 15.207 17 | 1 Mbps Frequency (MHz) 2388.4 2483.5 44.0 0.517 Measurement 651 kHz 6.5 dBm Limit at least 500 kHz 30 dBm Margin 23.5 dB 6.3 dBm/100 kHz 8.0 dBm/3 kHz -39.4 dBm -21.2 dBm -52.6 dBm -41.2 dBm 1.7 dB 18.2 dB 11.4 dB 38.2 dBµV/m 40.0 dBµV/m 1.8 dB 24.9 dBµV 46.0 dBµV 21.1 dB Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 7 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 4 REFERENCES Publication FCC eCFR 47 Part 15 ANSI C63.10 RSS-247 RSS-GEN KDB 558074 D01 Edition 3 5 - Date 2023 2020 2023 2018 2019 AMD 1 - 2019 - AMD 2 - 2021 - Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 8 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 5 UNCERTAINTY SUMMARY Using the guidance of the following publications the calculated measurement uncertainty represents an expanded uncertainty expressed at approximately the 95 % confidence level, using a coverage factor of k = 2. References CISPR 16-4-1 CISPR 16-4-2 CISPR 32 ANSI C63.23 A2LA P103 A2LA P103c ETSI TR 100-028 Measurement Type Radiated Emissions Radiated Emissions Radiated Emissions AC Line Conducted Emissions Telecom Conducted Emissions Disturbance Power Emissions Radiated Immunity Conducted Immunity EFT Burst/Surge ESD Immunity Configuration Biconical Antenna Log Periodic Antenna Horn Antenna Artificial Mains Network Asymmetric Artificial Network Absorbing Clamp 3 Volts/meter CDN/EM/BCI Peak pulse voltage 15 kV level Uncertainty ± 5.0 dB 5.3 dB 4.7 dB 3.4 dB 4.9 dB 4.1 dB 2.2 dB 2.4/3.5/3.4 dB 164 volts 1377 Volts Parameter Radio Frequency, from F0 Occupied Channel Bandwidth RF conducted Power (Power Meter) RF conducted emissions (Spectrum Analyzer) All emissions, radiated Temperature Humidity Supply voltages ETSI U.C. ± 1x10-7 5 % 1.5 dB 3.0 dB 6.0 dB 1° C 5 % 3 % U.C. ± 0.55x10-7 2 % 1.2 dB 1.7 dB 5.3 dB 0.65° C 2.9 % 1 % Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 9 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6 TEST DATA 6.1 Antenna Port Conducted Emissions Description of Measurement The direct measurement of emissions at the antenna port of the EUT is achieved by use of a RF connection to a spectrum analyzer or power meter. The cable and attenuator factors are loaded into the analyzer or power meter allowing for direct measurement readings without the need for further corrections. Example Calculations Measurement (dBm) + Cable factor (dB) + External Attenuator (dB) = Corrected Reading (dBm) Margin (dB) = Limit (dBm) Corrected Reading (dBm) Block Diagram EUT RF Cable Ext. Atten . Spectrum Analyzer/ Power Meter Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 10 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.1.1 6dB and 99% Occupied Bandwidth Operator Dylan Rosenfeldt Temperature 22.3°C Test Date 03/15/2024 Requirement 15.247 (a)(2) RSS-247 Clause 5.2 (a) QA R.H. % Location Method Limits: The minimum 6 dB bandwidth shall be at least 500 kHz Test Parameters Frequency 2400-2483.5 MHz RBW 99% OBW - 30 kHz 6dB DTS - 100 kHz Detector(s) Peak Setup VBW Settings Adam Hauke 30.30% Conducted RF Bench ANSI C63.10 6.9 Antenna Port 300 kHz Max Hold Instrumentation Asset # AA 960173 EE 960085 Description Cable Analyzer - EMI Receiver Manufacturer A.H. Systems, Inc. Agilent Model # SAC-26G-1 N9038A Serial # 388 MY51210148 Date 6/13/2023 4/27/2023 Due Date 6/12/2024 4/27/2024 Status Active Verification Active Calibration EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz Mode Channel BLE Tx See 2.10 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 11 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Table Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 0 19 39 0 19 39 0 19 39 0 19 39 6 dB BW (MHz) 696 699 686 1170 1166 1170 651 656 652 683 673 671 99% BW (MHz) 1029 1039 1038 2066 2068 2069 1057 1059 1059 1022 1019 1020 Plots Channel 0 | 500k | 6 dB DTS BW Channel 19 | 125k | 99% OBW Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 12 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.1.2 RF Output Power Operator Dylan Rosenfeldt Temperature 21.9°C-22.1°C Test Date 03/12/2024 | 03/15/2024 Requirement 15.247 (b)(3) RSS-247 Clause 5.4 (d) QA R.H. % Location Method Adam Hauke 31.50%-33.30% Conducted RF Bench ANSI C63.10 11.9.1 Limit: The maximum peak conducted output power of the intentional radiator shall not exceed 1 Watt. Test Parameters Frequency 2400-2483.5 MHz RBW 3 MHz Detector(s) Peak Setup VBW Settings Antenna Port 50 MHz Max Hold Span: 10 MHz Instrumentation Asset # AA 960173 EE 960088 Description Cable Analyzer - EMI Receiver Manufacturer A.H. Systems, Inc. Agilent Model # SAC-26G-1 N9038A Serial # 388 MY51210138 Date 6/13/2023 4/10/2023 Due Date 6/12/2024 4/10/2024 Status Active Verification Active Calibration EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz Mode Channel BLE Tx See 2.10 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 13 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Tables Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 0 19 39 0 19 39 0 19 39 0 19 39 Peak Output Power (dBm) 6.5 6.4 6.2 6.5 6.4 6.2 6.4 6.4 6.2 6.5 6.4 6.2 Limit (dBm) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 Margin (dB) 23.5 23.6 23.8 23.5 23.6 23.8 23.6 23.6 23.8 23.5 23.6 23.8 Plots Channel 0 | 1 Mbps Channel 19 | 2 Mbps Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 14 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.1.3 Power Spectral Density Operator Dylan Rosenfeldt Temperature 21.8°C Test Date 03/13/2024 Requirement 15.247 (e) RSS-247 Clause 5.2 (b) QA R.H. % Location Method Adam Hauke 33.70% Conducted RF Bench ANSI C63.10 11.10.2 Limits: Power spectral density shall not be greater than 8 dBm in any 3 kHz band. Test Parameters Frequency 2400-2483.5 MHz Detector(s) Peak RBW Notes 100 kHz VBW 300 kHz The same method of determining the conducted output power shall be used to determine the power spectral density Instrumentation Asset # AA 960173 EE 960088 Description Cable Analyzer - EMI Receiver Manufacturer A.H. Systems, Inc. Agilent Model # SAC-26G-1 N9038A Serial # 388 MY51210138 Date 6/13/2023 4/10/2023 Due Date 6/12/2024 4/10/2024 Status Active Verification Active Calibration EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz Mode Channel BLE Tx See 2.10 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 15 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Table Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 0 19 39 0 19 39 0 19 39 0 19 39 Peak PSD (dBm/100 kHz) 5.8 5.7 5.5 5.9 5.8 5.6 4.1 4.1 3.9 6.3 6.3 6.1 Limit (dBm/3 kHz) 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Margin (dB) 2.2 2.3 2.5 2.1 2.2 2.4 3.9 3.9 4.1 1.7 1.7 1.9 Plots Channel 0 | 125 kbps Channel 19 | 125 kbps Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 16 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.1.4 Out-of-band Emissions Operator Dylan Rosenfeldt Temperature 21.3°C | 22.0°C Test Date 03/18/2024 | 03/29/2024 Requirement 15.247(d) RSS-247 Clause 5.5 QA R.H. % Location Method Adam Alger 23.00% | 24.60% Conducted RF Bench ANSI C63.10 11.12.2.5.2 Limits: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement provided the transmitter demonstrates compliance with the peak conducted power limits. Reference Level (Worst Case PSD) Channel 0 125 kbps 6.3 dBm/100 kHz 6.3 dBm-20 dB = -13.7 dBm Limit Test Parameters Frequency 30-40000 MHz Setup Antenna Port RBW 100 kHz VBW 300 kHz Detector(s) Peak and Average (RMS) Notes Example Calculations Declared antenna gain for band edge 2.5 dBi Correction Factor = 20 log (1/D), where D is the duty cycle Instrumentation Asset # AA 960172 EE 960085 EE 960087 AA 960173 Description Cable Analyzer Spectrum Analyzer Spectrum Cable Manufacturer A.H. Systems, Inc. Agilent Agilent A.H. Systems, Inc. Model # SAC-26G-1 N9010A N9010A SAC-26G-1 Serial # 387 MY53400296 MY53400296 388 Date 06/13/2023 04/11/2023 4/11/2023 6/13/2023 Due Date 06/12/2024 04/11/2024 4/11/2024 6/12/2024 Status Active Verification Active Calibration Active Calibration Active Verification Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 17 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz Mode Channel 2.4 GHz WLAN Tx See 2.8 Measurements Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 0 0 0 0 39 Frequency (MHz) 2388.6 2400.0 2388.7 2388.5 27277.1 Measurement (dBm) -49.8 -25.9 -51.0 -50.0 -63.5 Limit (dBm) -13.7 -13.7 -13.7 -13.7 -13.7 Margin (dB) 36.1 12.2 37.3 36.3 49.8 Worst Case Plots Channel 0 |125 kbps | Reference Channel 0 | 2 Mbps | 30-2400 MHz Channel 39| 125 kbps | 2500-40000 MHz Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 18 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.1.5 Spurious Emissions in Restricted Bands Operator Dylan Rosenfeldt Temperature 21.7°C | 20.9°C Test Date 03/08/2024 | 03/11/2024 Requirement 15.247(d) RSS-247 Clause 5.5 QA R.H. % Location Method Adam Alger 34.40% | 24.90% Conducted RF Bench ANSI C63.10 11.12.2.5.2 15.209 Limits: Frequency (MHz) 30-88 88-216 216-960 960-1000 1000-40000 Quasi-Peak Limit (dBµV/m) 40.0 43.5 46.0 54.0 - Average Limit (dBµV/m) 54.0 Peak Limit (dBµV/m) 74.0 Test Parameters Frequency 30-40000 MHz Setup Antenna Port RBW 1 MHz VBW 3 MHz Detector(s) Peak Method Terminated Notes Example Calculations Declared antenna gain 2.5 dBi Correction Factor = 20 log (1/D), where D is the duty cycle EIRP = Measurement + Antenna Gain + Correction Factor E-Field = EIRP 20log3 + 104.8 Instrumentation Asset # AA 960172 EE 960085 EE 960087 AA 960173 Description Cable Analyzer Spectrum Analyzer Spectrum Cable Manufacturer A.H. Systems, Inc. Agilent Agilent A.H. Systems, Inc. Model # SAC-26G-1 N9010A N9010A SAC-26G-1 Serial # 387 MY53400296 MY53400296 388 Date 06/13/2023 04/11/2023 4/11/2023 6/13/2023 Due Date 06/12/2024 04/11/2024 4/11/2024 6/12/2024 Status Active Verification Active Calibration Active Calibration Active Verification Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 19 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2402 MHz | 2440 MHz Mode Channel BLE Tx 0 | 19 Measurements Lower Band Edge Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 0 0 0 0 0 0 0 0 Measurement Type Peak Average Peak Average Peak Average Peak Average Frequency (MHz) 2388.4 2385.1 2388.3 2384.9 2388.7 2385.0 2388.4 2385.0 Measurement (dBm) -41.9 -62.8 -42.0 -63.7 -42.3 -63.3 -42.2 -63.1 EIRP (dBm) -39.4 -60.3 -39.5 -61.2 -39.8 -60.8 -39.7 -60.6 E-Field (dBµV/m) 55.9 35.0 55.8 34.1 55.5 34.5 55.6 34.7 Limit (dBµV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 18.1 19.0 18.2 19.9 18.5 19.5 18.4 19.3 Measurements Upper Band Edge Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 39 39 39 39 39 39 39 39 Measurement Type Peak Average Peak Average Peak Average Peak Average Frequency (MHz) 2484.9 2483.5 2483.6 2483.5 2485.2 2483.5 2485.0 2483.5 Measurement (dBm) -39.0 -61.2 -39.1 -55.1 -39.7 -61.6 -40.2 -61.8 EIRP (dBm) -36.5 -58.7 -36.6 -52.6 -37.2 -59.1 -37.7 -59.3 E-Field (dBµV/m) 58.8 36.6 58.7 42.7 58.1 36.2 57.6 36.0 Limit (dBµV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 15.2 17.4 15.3 11.3 15.9 17.8 16.4 18.0 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 20 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Band Edge Worst Case Plots Channel 0 | 1 Mbps | Peak Channel 0 | 1 Mbps | Average Channel 39 | 2 Mbps | Peak Channel 39 | 2 Mbps | Average Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 21 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Spurious Table Rate 1 Mbps 2 Mbps 500 kbps 125 kbps Channel 0 0 0 0 0 0 19 19 Measurement Type Peak Average Peak Average Peak Average Peak Average Frequency (MHz) 2241.9 2281.7 2241.3 2281.3 2241.8 2294.5 2241.9 2281.6 Measurement (dBm) -50.7 -68.3 -51.9 -68.3 -51.5 -69.8 -51.8 -69.1 EIRP (dBm) -48.2 -65.8 -49.4 -65.8 -49.0 -67.3 -49.3 -66.6 E-Field (dBµV/m) 47.1 29.5 45.9 29.5 46.3 28.0 46.0 28.7 Limit (dBµV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 26.9 24.5 28.1 24.5 27.7 26.0 28.0 25.3 Spurious Worst Case Plots Channel 19 | 2 Mbps | 30-1000 MHz Channel 0 | 1 Mbps | 1000-2310 MHz Channel 39 | 2 Mbps | 2500-4000 MHz Channel 0 | 1 Mbps | 4000-40000 MHz Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 22 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.1.6 Frequency Stability Operator Dylan Rosenfeldt Temperature 21.6°C Test Date 04/25/2024 Requirement 15.407(g) RSS-GEN Clause 6.11 Test Parameters Frequency 2402-2480 MHz Detector(s) Peak QA R.H. % Location Method Anthony Smith 30.00% Conducted RF Bench ANSI C63.10 6.8 Voltage Settings 4.3 VDC, 5 VDC, and 5.8 VDC Max Hold Instrumentation Asset # AA 960173 EE 960088 Description Cable Analyzer - EMI Receiver Manufacturer A.H. Systems, Inc. Agilent Model # SAC-26G-1 N9038A Serial # 387 MY51210138 Date 06/13/2023 4/10/2023 Due Date 06/12/2024 4/10/2024 Status Active Verification Active Calibration Table Channel 0 19 39 Voltage (VDC) 5 4.3 5.8 5 4.3 5.8 5 4.3 5.8 Center Frequency (Hz) 2402000851 2402000810 2402000778 2439999709 2439999658 2439999602 2480001126 2480000919 2480000395 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 23 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.2 Radiated Emissions The frequency spectrum is investigated for intentional and / or unintentional signals emanating from the EUT by use of a standardized test site and measurement antenna. Description of Measurement The antenna, cable, pre-amp, and other necessary measurement system correction factors are loaded onto the EMI receiver / spectrum analyzer when the measurements are performed allowing the data to be gathered and reported as corrected values. The maximum emissions from the EUT are determined by turn-table azimuth rotation (360°) and scanning of the measurement antenna. Maximized levels are noted at degree values of azimuth, measurement antenna height, and measurement antenna polarity. Measurement (dBµV) + Cable factor (dB) + Other (dB) + Antenna Factor (dB/m) = Corrected Reading (dBµV/m) Example Calculations Margin (dB) = Limit (dBµV/m) - Corrected Reading (dBµV/m) Example at 4000 MHz: Reading = 40 dBµV + 3.4 dB + 0.9 dB + 6.5 dB/m = 50.8 dBµV/m Average Limit = 20 log (500) = 54 dBµV/m Margin = 54 dBµV/m - 50.8 dBµV/m = 3.2 dB Block Diagram EMI Receiver / Spectrum Antenna EUT Analyzer Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 24 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.2.1 Spurious Radiated Emissions in the Restricted Bands Operator Mitchell Freund | Nicole Sedmak Jon Dilley | Zachary Brown Temperature 23.4°C-24.0°C QA R.H. % Anthony Smith | Adam Alger Adam Hauke | Dylan Rosenfeldt 19.90%-32.40% Test Date Requirement 03/14/2024-03/21/2024 15.247 (d) | 15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.9 Location Method Chamber 3 | Chamber 5 ANSI C63.10 15.209 Limits: Frequency (MHz) 30-88 88-216 216-960 960-1000 1000-40000 Quasi-Peak Limit (dBµV/m) 40.0 43.5 46.0 54.0 - Average Limit (dBµV/m) 54.0 Peak Limit (dBµV/m) 74.0 Test Parameters Frequency Detector(s) RBW 30-40000 MHz Peak Trace Peak and Average Final <1000 MHz 120 kHz >1000 1 MHz Distance 3 m Table height VBW 150 cm <1000 1.2 MHz >1000 See 2.9 Instrumentation Asset # AA 960007 AA 960081 AA 960154 AA 960163 AA 960217 AA 960221 EE 960085 Description Antenna Double Ridge Horn Antenna Double Ridge Horn Filter - High Pass 2.4 GHz Antenna - Log Periodic Antenna Biconical Cable Analyzer EMI Receiver Manufacturer EMCO EMCO KWM A.H. Systems, Inc. A.H. Systems, Inc. A.H. Systems, Inc. Agilent Model # 3115 3115 HPF-L-14186 SAS-512-2 SAS-540 SAC-26G-6 N9038A Serial # 9311-4138 6907 7272-02 500 852 524 MY51210148 Date 8/10/2023 1/11/2024 4/11/2023 8/10/2023 7/17/2023 6/13/2023 4/27/2023 Due Date 8/10/2024 1/11/2025 4/11/2024 8/10/2024 7/17/2024 6/13/2024 4/27/2024 Status Active Calibration Active Calibration Active Calibration Active Calibration Active Calibration Active Verification Active Calibration Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 25 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 EE 960203 LSC-300 LSC-500 Analyzer EMI Receiver Cable Cable Keysight Chamber 3 Emissions Chamber 5 Emissions N9038A - MY56400072 - 4/11/2023 1/5/2024 1/8/2024 4/11/2024 1/5/2025 1/8/2025 Active Calibration Active Verification Active Verification EUT Parameters Input Power EUT Notes 120 VAC @ 60 Hz Mode BLE Tx X, Y, Z Plane Orientations Antenna ports terminated with AE 50 SMA terminators HP Elitebook 840G1 Ezurio SOM60 Development Kit 6000 MHz Emission from auxiliary equipment. Not a function of the EUT. Radiated Spurious 30-1000 MHz Channel 19 1 Mbps Frequency (MHz) 44.0 44.0 78.0 125.0 220.0 308.0 375.0 396.3 479.9 Antenna Polarity V H V V H V H H V Height (cm) 103 276 140 159 164 175 308 125 135 Azimuth (degree) 256 247 55 261 329 162 341 327 17 Quasi-Peak Reading (dBµV/m) 30.7 38.2 34.3 37.0 36.6 40.3 39.9 38.7 40.4 Quasi-Peak Limit (dBµV/m) 40.0 40.0 40.0 43.5 46.0 46.0 46.0 46.0 46.0 Margin (dB) 9.3 1.8 5.7 6.5 9.4 5.7 6.7 7.3 5.6 *The spurious signals detected do not depend on either the operating channel or the modulation mode 1000-40000 MHz Band Edge Channel EUT Orientation 0 X Plane 39 Z Plane Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Data Rate 125 kbps 500 kbps 1 Mbps 2 Mbps 125 kbps 500 kbps Measurement Type Peak Average Peak Average Peak Average Peak Average Peak Average Peak Average Frequency (MHz) 2342.0 2348.3 2325.2 2384.9 2365.7 2349.5 2388.4 2387.9 2487.1 2491.6 2484.0 2486.0 Page 26 of 32 Antenna Polarity H H H H H H H H H H H H Measurement (dBµV/m) 52.2 41.0 52.4 40.3 52.0 41.6 51.8 42.3 51.8 40.9 52.0 40.4 Limit (dBµV/m) 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 Margin (dB) 16.0 13.0 15.8 13.7 16.2 12.4 16.4 11.7 16.4 13.1 16.2 13.6 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 1 Mbps Peak Average 2492.9 2487.0 H H 2 Mbps Peak Average 2487.9 2484.5 H H Spurious No Emissions Present Worst Case Plots 53.4 74.0 14.8 41.6 54.0 12.4 52.3 74.0 15.9 42.3 54.0 11.7 Channel 19 | 1 Mbps 30-200 MHz | Vertical Channel 0 | 1 Mbps 200-1000 MHz | Vertical Channel 0 | 125 kbps 1000-2310 MHz | Horizontal Channel 0 | 125 kbps 2500-4000 MHz | Vertical Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 27 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Channel 0 | 1 Mbps 4000-18000 MHz | Vertical Channel 19 | 1 Mbps 18000-40000 MHz | Vertical Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 28 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.3 AC Mains Conducted Emissions A line impedance stabilization network (LISN) or artificial mains network (AMN) allows the emissions of the power supply conductors to be measured while isolating the EUT from the supply mains. The AMN, cable, and other necessary measurement system correction factors are Description of Measurement loaded onto the EMI receiver when the measurements are performed. The data is gathered and reported as the corrected values. Maximum emissions are determined with a peak max hold trace then measurements at a selection of the highest points are made with quasi-peak and average detectors. Results are recorded and compared to limit for each line. (e.g. line and neutral) Example Calculations Measurement (dBµV) + Cable factor (dB) + Other (dB) = Corrected Reading (dBµV) Margin (dB) = Limit (dBµV) - Corrected Reading (dBµV) Block Diagram EUT AMN Cable EMI Receiver Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 29 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 6.3.1 AC Mains Conducted Emissions Operator Jon Dilley Temperature 20.8°C Test Date 1/22/2024 Requirement 15.207 QA R.H. % Location Method Adam Hauke 19.60% AC Conducted Bench ANSI C63.10 Limits: Frequency (MHz) Quasi-Peak Limit (dBµV) 0.15-0.5 66.0-56.0* 0.5-5 56.0 5-30 60.0 *Decreases with the logarithm of the frequency. Average Limit (dBµV) 56.0-46.0* 46.0 50.0 Test Parameters Frequency Detector(s) RBW Notes 0.15-30 MHz Distance Peak Trace Quasi-Peak, Average Final 9 kHz Table height VBW Channel has no effect on emission 40 cm from wall 80 cm from LISN 80 cm 62 kHz Instrumentation Asset # EE 960088 EE 960089 Description Analyzer - EMI Receiver LISN Manufacturer Agilent COM-POWER Model # N9038A LI-215A Serial # MY51210148 191943 EE 960162 LSC-212 LISN Cable COM-POWER Micro-Coax LI-215A UFB311A-01440-70U70U 191969 64639 224071001 Date 4/27/2023 4/10/2023 4/10/2023 1/8/2024 Due Date 4/27/2024 4/10/2024 4/10/2024 1/8/2025 Status Active Calibration Active Calibration Active Calibration Active Verification EUT Parameters Input Power 120 VAC @ 60 Hz Mode BLE Tx Channel 17 1 Mbps Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 30 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 Measurements Line Frequency (MHz) 1 0.159 1 0.517 1 11.870 2 0.155 2 0.530 2 11.780 Quasi Peak Reading (dBµV) 38.3 30.7 35.6 39.0 29.2 28.4 QuasiPeak Limit (dBµV) 65.5 56.0 60.0 65.8 56.0 60.0 Quasi Peak Margin (dB) 27.2 25.3 24.4 26.8 26.8 31.6 Plots Average Reading (dBµV) 29.2 24.9 24.9 29.7 22.2 14.3 Average Limit (dBµV) 55.5 46.0 50.0 55.8 46.0 50.0 Average Margin (dB) 26.3 21.1 25.1 26.1 23.9 35.7 Line 1 Line 2 Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 31 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047 7 REVISION HISTORY Version 0.0 1.0 Date 08/05/2024 08/08/2024 Notes Initial Draft Final Draft END OF REPORT Person Adam Hauke Adam Hauke Company: Ezurio Report: TR3768-165-BLE Job: C-3768 Page 32 of 32 Name: Module, SONA NX611 M.2 2230, 2 MHF Model: SONA NX611M Serial: 00047
Related FCC IDs:
- SQG-SONANX611M - Ezurio LLC Wi-Fi 6/BT Transceiver radio [-SONANX611M] Microsoft: Print To PDF