ST1 NA Rev F 0412-161-349

Juniper Systems, Inc. 29579 AC9260 VSF29579 VSF29579 29579

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 189 Pages, 4.56MB

Document DEVICE REPORTGetApplicationAttachment.html?id=6487034
Report Number: SAR.20220203

SAR Data Summary ­ 835 MHz Body ­ LTE Band 26

MEASUREMENT RESULTS

Gap Plot

-----

-----

6

-----

-----

0

-----

mm -----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeated
Left

Frequency

MHz 831.5 831.5 819.0 831.5 844.0 819.0 831.5 844.0 831.5 831.5 831.5 819.0

Ch. 26865 26865 26740 26865 26990 26740 26865 26990 26865 26865 26865 26740

831.5 26865

BW/ Modulation
10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK 10 MHz/QPSK
10 MHz/QPSK

RB Size
1 25 1 1 1 25 25 25 50 1 25 1
1

RB Offset
24 13 24 24 24 13 13 13 0 24 13 24
24

MPR Target
0 1 0 0 0 1 1 1 1 0 1 0
0

End Power
(dBm) 20.5 19.3 20.7 20.5 20.3 19.2 19.3 19.2 19.7 20.5 19.3 20.7
23.1

Measured SAR (W/kg) 0.392 0.24 1.21 1.15 0.986 0.696 0.716 0.629 0.647 0.107 0.057 1.19
0.736

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.44 0.28 1.30 1.29 1.16 0.84 0.84 0.76 0.69 0.12 0.07 1.28
0.81

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President
Note: Band 5 LTE is fully within the frequency band of B26. Therefore, Band 5 was not tested for standalone SAR.

© 2022 RF Exposure Lab, LLC

Page 161 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 1750 MHz Body - WCDMA

MEASUREMENT RESULTS

Gap Plot

Frequency MHz Ch.

Rev Level/ Modulation

---- 1732.6 1413 WCDMA

---- 1712.4 1312 WCDMA

0 ---- 1732.6 1413 WCDMA

mm 7 1752.6 1513 WCDMA

---- 1732.6 1413 WCDMA

---- 1752.6 1513 WCDMA

22 mm

----

1752.6 1513

WCDMA

Position
Back
Left
Top Repeat
Left

End Power (dBm) 16.74 16.67 16.74 17.00 16.74 17.00
24.00

RMC
12.2 kbps 12.2 kbps 12.2 kbps 12.2 kbps 12.2 kbps 12.2 kbps
12.2 kbps

Test Set Up
Test Loop 1 Test Loop 1 Test Loop 1 Test Loop 1 Test Loop 1 Test Loop 1
Test Loop 1

Measured SAR (W/kg) 0.243 0.621 0.968 1.04 0.0864 1.02
0.867

Reported SAR (W/kg) 0.26 0.67 1.03 1.04 0.09 1.02
0.87

Head 1.6 W/kg (mW/g)
averaged over 1 gram

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 162 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 1750 MHz Body ­ LTE Band 66

MEASUREMENT RESULTS

Gap Plot

-----

-----

-----

-----

8

0

-----

mm -----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeated
Left

Frequency

MHz 1745.0 1745.0 1720.0 1745.0 1780.0 1720.0 1745.0 1780.0 1780.0 1745.0 1745.0 1780.0

Ch. 132322 132322 132072 132322 132572 132072 132322 132572 132572 132322 132322 132572

1780.0 132572

BW/ Modulation
20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK
20 MHz/QPSK

RB Size
1 50 1 1 1 50 50 50 100 1 50 1
1

RB Offset
49 24 49 49 49 24 24 24 0 49 24 49
49

MPR Target
0 1 0 0 0 1 1 1 1 0 1 0
0

End Power
(dBm) 20.4 19.2 20.4 20.4 20.3 18.8 19.2 19.0 19.0 20.4 19.2 20.4
22.9

Measured SAR (W/kg) 0.256 0.255 0.895 1.02 1.08 0.817 0.885 0.856 0.751 0.0908 0.0902 1.06
0.872

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.26 0.27 0.92 1.04 1.13 0.96 0.95 0.96 0.84 0.09 0.10 1.08
1.00

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President
Note: Band 4 LTE is fully within the frequency band of B66. Therefore, Band 4 was not tested for standalone SAR.

© 2022 RF Exposure Lab, LLC

Page 163 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 1900 MHz Body - WCDMA

MEASUREMENT RESULTS

Gap Plot

Frequency MHz Ch.

Rev Level/ Modulation

---- 1880.0 9400 WCDMA

---- 1852.4 9262 WCDMA

0 ---- 1880.0 9400 WCDMA

mm 9 1907.6 9538 WCDMA

---- 1852.4 9262 WCDMA

---- 1907.6 9538 WCDMA

22 mm

----

1907.6 9538

WCDMA

Position
Back
Left
Top Repeat
Left

End Power (dBm) 15.94 15.96 15.94 15.98 15.94 15.98
23.82

RMC
12.2 kbps 12.2 kbps 12.2 kbps 12.2 kbps 12.2 kbps 12.2 kbps
12.2 kbps

Test Set Up
Test Loop 1 Test Loop 1 Test Loop 1 Test Loop 1 Test Loop 1 Test Loop 1
Test Loop 1

Measured SAR (W/kg) 0.128 1.08 1.07 1.09 0.0679 1.07
0.927

Reported SAR (W/kg) 0.13 1.09 1.09 1.10 0.07 1.08
0.97

Head 1.6 W/kg (mW/g)
averaged over 1 gram

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 164 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 1900 MHz Body ­ LTE Band 25

MEASUREMENT RESULTS

Gap Plot

-----

-----

-----

10

-----

0

-----

mm -----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeated
Left

Frequency

MHz 1880.0 1880.0 1860.0 1880.0 1900.0 1860.0 1880.0 1900.0 1860.0 1880.0 1880.0 1880.0

Ch. 18900 18900 18700 18900 19100 18700 18900 19100 18700 18900 18900 18900

1880.0 18900

BW/ Modulation
20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK
20 MHz/QPSK

RB Size
1 50 1 1 1 50 50 50 100 1 50 1
1

RB Offset
49 24 49 49 49 24 24 24 0 49 24 49
49

MPR Target
0 1 0 0 0 1 1 1 1 0 1 0
0

End Power
(dBm) 18.9 17.4 18.8 18.9 18.8 17.9 17.4 17.6 17.8 18.9 17.4 18.9
23.0

Measured SAR (W/kg) 0.266 0.252 1.01 1.04 1.01 0.907 0.893 0.897 0.857 0.121 0.120 1.02
0.824

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.27 0.29 1.06 1.06 1.06 0.93 1.03 0.98 0.90 0.12 0.14 1.04
0.92

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President
Note: Band 2 LTE is fully within the frequency band of B25. Therefore, Band 2 was not tested for standalone SAR.

© 2022 RF Exposure Lab, LLC

Page 165 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 2600 MHz Body ­ LTE Band 7

MEASUREMENT RESULTS

Gap Plot

-----

-----

-----

11

-----

0

-----

mm -----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeat
Left

Frequency

MHz 2560.0 2510.0 2510.0 2535.0 2560.0 2510.0 2535.0 2560.0 2535.0 2535.0 2535.0 2535.0

Ch. 21350 20850 20850 21100 21350 20850 21100 21350 21100 21100 21100 21100

2535.0 21100

BW/ Modulation
20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK
20 MHz/QPSK

RB Size
1 50 1 1 1 50 50 50 100 1 50 1
1

RB Offset
49 24 49 49 49 24 24 24 0 49 24 49
49

MPR Target
0 1 0 0 0 1 1 1 1 0 1 0
0

End Power
(dBm) 17.9 16.8 17.8 17.9 17.8 17.0 16.8 16.7 16.9 17.9 16.8 17.9
22.6

Measured SAR (W/kg) 0.216 0.191 1.04 1.09 1.02 0.957 0.972 0.986 0.901 0.102 0.0420 1.07
0.922

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.22 0.20 1.09 1.12 1.07 0.96 1.02 1.06 0.92 0.10 0.04 1.09
1.01

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 166 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 2550 MHz Body ­ LTE Band 41

MEASUREMENT RESULTS

Gap Plot

-----

-----

-----

-----

12

0

-----

mm -----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeated
Left

Frequency

MHz 2593.0 2593.0 2506.0 2544.5 2593.0 2641.5 2680.0 2593.0 2593.0 2593.0 2593.0 2593.0

Ch. 40620 40620 39750 40135 40620 41105 41490 40620 40620 40620 40620 40620

2593.0 40620

BW/ Modulation
20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK
20 MHz/QPSK

RB Size
1 50 1 1 1 1 1 50 100 1 50 1
1

RB Offset
49 24 49 49 49 49 49 24 0 49 24 49
49

MPR Target
0 1 0 0 0 0 0 1 1 0 1 0
0

End Power
(dBm) 21.6 20.6 21.6 21.8 21.6 21.8 21.5 20.6 19.9 21.6 20.6 21.6
22.8

Measured SAR (W/kg) 0.233 0.152 0.951 0.938 1.01 0.927 0.894 0.774 0.602 0.107 0.0784 0.994
0.658

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.26 0.17 1.04 0.98 1.11 0.97 1.00 0.85 0.78 0.12 0.09 1.09
0.69

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 167 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 3500 MHz Body ­ LTE Band 42

MEASUREMENT RESULTS

Gap Plot

-----

-----

-----

-----

13

-----

-----

0

-----

mm -----

-----

-----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeated
Left

Frequency

MHz 3500.0 3500.0 3410.0 3445.0 3500.0 3545.0 3590.0 3410.0 3445.0 3500.0 3545.0 3590.0 3590.0 3500.0 3500.0 3500.0

Ch. 42590 42590 41690 42040 42590 43040 43490 41690 42040 42590 43040 43490 43490 42590 42590 42590

3500.0 42590

BW/ Modulation
20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK
20 MHz/QPSK

RB Size
1 50 1 1 1 1 1 50 50 50 50 50 100 1 50 1
1

RB Offset
49 24 49 49 49 49 49 24 24 24 24 24 0 49 24 49
49

MPR Target
0 1 0 0 0 0 0 1 1 1 1 1 1 0 1 0
0

End Power
(dBm) 19.7 18.7 19.8 19.7 19.7 19.9 19.9 18.9 18.4 18.7 18.4 18.4 18.9 19.7 18.7 19.7
22.6

Measured SAR (W/kg) 0.136 0.121 0.952 0.936 0.999 0.966 0.974 0.792 0.806 0.801 0.819 0.806 0.766 0.217 0.109 0.981
0.624

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.15 0.13 1.00 1.00 1.07 0.99 1.00 0.81 0.93 0.86 0.94 0.93 0.78 0.23 0.12 1.05
0.68

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 168 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ 3500 MHz Body ­ LTE Band 48

MEASUREMENT RESULTS

Gap Plot

-----

-----

-----

-----

14

-----

-----

0

-----

mm -----

-----

-----

-----

-----

-----

-----

-----

22 mm

-----

Position Back
Left
Top Repeated
Left

Frequency

MHz 3625.0 3625.0 3560.0 3592.5 3625.0 3657.5 3690.0 3560.0 3592.5 3625.0 3657.5 3690.0 3592.5 3625.0 3625.0 3625.0

Ch. 55990 55990 55340 55665 55990 56315 56640 55340 55665 55990 56315 56640 55665 55990 55990 55990

3625.0 55990

BW/ Modulation
20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK 20 MHz/QPSK
20 MHz/QPSK

RB Size
1 50 1 1 1 1 1 50 50 50 50 50 100 1 50 1
1

RB Offset
49 24 49 49 49 49 49 24 24 24 24 24 0 49 24 49
49

MPR Target
0 1 0 0 0 0 0 1 1 1 1 1 1 0 1 0
0

End Power
(dBm) 19.9 19.0 19.9 19.7 19.9 19.7 19.9 18.5 18.5 19.0 18.4 18.5 18.8 19.9 19.0 19.9
22.8

Measured SAR (W/kg) 0.142 0.0567 1.06 1.01 1.08 1.04 1.00 0.941 0.952 0.992 0.906 0.955 0.844 0.107 0.0416 1.06
0.822

Head 1.6 W/kg (mW/g) averaged over 1 gram

Reported SAR (W/kg) 0.15 0.06 1.09 1.08 1.11 1.11 1.02 1.06 1.07 0.99 1.04 1.07 0.88 0.11 0.04 1.08
0.86

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 169 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
SAR Data Summary ­ 2450 MHz Body 802.11b & BT

MEASUREMENT RESULTS

Plot Gap Position

---------

Back

-----

--------15

0 mm

Top Left

-----

Back

-----

Left

-----

Repeated

Frequency
MHz Ch.
2437 6 2437 6 2437 6 2462 11 2437 6 2462 11 2441 39 2441 39 2462 11

Modulation Antenna

DSSS DSSS DSSS DSSS DSSS DSSS GMSK GMSK DSSS

Primary Secondary
Primary
Secondary
Secondary Secondary Secondary

End Power
(dBm)
14.50 14.50 14.50 14.42 14.50 14.46 11.47 11.47 14.46

Measured SAR (W/kg) 0.198 0.126 0.731 0.762 1.05 1.08 0.0632 0.353 1.06

Reported SAR (W/kg) 0.31 0.13 1.16 1.23 1.05 1.09 0.07 0.40 1.07

Head 1.6 W/kg (mW/g)
averaged over 1 gram

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 170 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
SAR Data Summary ­ 5250 MHz Body 802.11a

MEASUREMENT RESULTS

Plot Gap

-----

-----

-------------

0 mm

16

-----

Position
Back Top Left Repeated

Frequency
MHz Ch.
5300 60 5300 60 5280 56 5300 60 5280 56 5300 60 5300 60

Modulation
OFDM OFDM OFDM OFDM OFDM OFDM OFDM

Antenna
Primary Secondary
Primary
Secondary Secondary

End Power
(dBm)
12.75 12.75 12.75 12.75 12.75 12.75 12.75

Measured SAR (W/kg) 0.287 0.125 0.685 0.682 1.03 1.06 1.04

Reported SAR (W/kg) 0.46 0.13 1.09 1.08 1.03 1.06 1.04

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

Head 1.6 W/kg (mW/g)
averaged over 1 gram

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip

N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 171 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
SAR Data Summary ­ 5600 MHz Body 802.11a

MEASUREMENT RESULTS

Plot Gap

-----

-----

----17 -----

0 mm

-----

-----

Position
Back Top Left Repeated

Frequency
MHz Ch. 5620 124 5620 124 5580 116 5620 124 5580 116 5620 124 5620 124

Modulation
OFDM OFDM OFDM OFDM OFDM OFDM OFDM

Antenna
Primary Secondary
Primary
Secondary Primary

End Power (dBm) 12.50 12.50 12.50 12.50 12.50 12.50 12.50

Measured SAR (W/kg) 0.307 0.125 1.02 1.09 1.03 1.04 1.07

Reported SAR (W/kg) 0.43 0.13 1.44 1.54 1.03 1.04 1.51

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

Head 1.6 W/kg (mW/g)
averaged over 1 gram

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip

N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 172 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
SAR Data Summary ­ 5800 MHz Body 802.11a

MEASUREMENT RESULTS

Frequency Plot Gap Position
MHz Ch.

---------

Back

5785 157 5785 157

18 ---------

0 mm

-----

Top Left

5785 157 5825 165 5785 157 5825 165

-----

Repeated 5785 157

Modulation
OFDM OFDM OFDM OFDM OFDM OFDM OFDM

Antenna
Primary Secondary
Primary
Secondary Primary

End Power
(dBm)
13.00 13.00 13.00 13.00 13.00 13.00 13.00

Measured SAR (W/kg) 0.311 0.111 1.06 1.03 1.01 1.04 1.04

Reported SAR (W/kg) 0.39 0.11 1.33 1.30 1.01 1.04 1.31

Head 1.6 W/kg (mW/g)
averaged over 1 gram

1. Battery is fully charged for all tests.

Power Measured

Conducted

2. SAR Measurement

Phantom Configuration

Left Head

SAR Configuration

Head

3. Test Signal Call Mode

Test Code

4. Test Configuration

With Belt Clip

5. Tissue Depth is at least 15.0 cm

ERP

EIRP

Eli4

Right Head

Body

Base Station Simulator

Without Belt Clip N/A

Jay M. Moulton Vice President

© 2022 RF Exposure Lab, LLC

Page 173 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Carrier Aggregation Evaluation

Report Number: SAR.20220203

Downlink Only Carrier Aggregation

This device supports LTE Carrier Aggregation (CA) in the downlink. All uplink communications are identical to Release 8 specifications. Per FCC KDB Publication 941225 D05A v01r02 and Fall 2017 TCB Workshop Notes, SAR for LTE CA operations was not needed since the maximum average output power in LTE CA mode was not >0.25 dB higher than the maximum output power when downlink carrier aggregation was inactive.
Conducted power measurements with LTE Carrier Aggregation (CA) (downlink only) active are made in accordance to KDB Publication 941225 D05A v01r02. The RRC connection is only handled by one cell, the primary component carrier (PCC) for downlink and uplink communications. After making a data connection to the PCC, the UE device adds secondary component carrier(s) (SCC) on the downlink only. All uplink communications and acknowledgements remain identical to specifications when downlink carrier aggregation is inactive on the PCC. For every supported combination of downlink only carrier aggregation, additional conducted output power are measured with the downlink carrier aggregation active for the configuration with the highest measured maximum conducted power with downlink carrier aggregation inactive measured among the channel bandwidth, modulation and RB combinations in each frequency band. Per FCC KDB Publication 941225 D05A v01r02, no SAR measurements are required for carrier aggregation configurations when the average output power with downlink only carrier aggregation active is not more than 0.25 dB higher than the average output power with the downlink only carrier aggregation inactive.
Uplink Only Carrier Aggregation
This device supports LTE Carrier Aggregation (CA) in the uplink for LTE Band 5, Band 7, Band 41, Band 42, Band 43 and Band 48 with two component carriers in the uplink. SAR measurements and conducted powers were evaluated per 2017 Fall TCB Workshop Notes and 2018 Fall TCB Workshop Notes.
For LTE Band 5, Band 7, Band 41, Band 42, Band 43 and Band 48, per Fall 2018 Workshop Notes, SAR was first measured with only a single carrier active in the uplink (carrier aggregation not active). For each inter-band exposure condition, the single uplink SAR values are provided in table 2 below. If the single uplink 1 gram SAR values for each band are both less than 0.8 W/kg and the algebraic summation of the 1 gram SAR values are less than 1.45 W/kg no additional measurements are required. See table 3 below for results.
MIMO
This device only supports LTE downlink 2x2 MIMO. Per Fall 2017 TCB Workshop Notes, SAR for LTE MIMO operations was not needed since the maximum average output power in LTE MIMO mode was not >0.25 dB higher than the maximum output power when MIMO is inactive. See Appendix H for conducted power data.

© 2022 RF Exposure Lab, LLC

Page 174 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

Table 1 ­ Carrier Aggregation Downlink Combinations

1 Band/2CC 2A-2A 2C XXXXX XXXXX XXXXX XXXXX 4A-4A XXXXX XXXXX XXXXX XXXXX 5B 7A-7A 7B 7C 12B XXXXX XXXXX
25A-25A XXXXX 41A-41A
41C 42A 42A 42C43C 48A-48A 48C 66A-66A 66B 66C

2 Band/2CC 2A-5A 2A-7A 2A-12A 2A-13A 2A-14A 2A-71A 4A-5A 4A-7A 4A-12A 4A-13A 4A-71A 5A-66A 7A-12A XXXXX XXXXX
12A-66A 13A-66A 14A-66A 25A-26A 26A-41A XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX XXXXX 66A-71A XXXXX XXXXX

© 2022 RF Exposure Lab, LLC

Page 175 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

SAR Data Summary ­ Simultaneous Transmit (WWAN-WLAN Main)
MEASUREMENT RESULTS

Plot

Position SAR (W/kg) WLAN SAR (W/kg) WWAN

Total SAR (W/kg)

-----

Back

0.46

0.47

0.93

-----

Left

0.40

1.53

1.93

-----

Top

1.54

0.26

1.80

Head 1.6 W/kg (mW/g) averaged over 1 gram
The WLAN Left side SAR value was calculated per KDB447498 D01 v06 section 4.3.2 b) 1). The antenna is more than 50 mm from the left side; therefore, the SAR value is set at 0.4 W/kg.

MEASUREMENT RESULTS ­ WWAN-WiFi (Main)

Position Left

Frequency MHz Ch. 5620 124

Maxima

X

Y

Z

----

----

----

Frequency

MHz

Ch.

846.4

4233

Left ­ 126.2 mm

SPLSR=0.02

Maxima

X

Y

4.00

30.00

Z -0.06

SAR1 0.40

SAR2 1.53

SAR Total 1.93

Head Tissue 1.6 W/kg (mW/g) averaged over 1 gram

Simultaneous Separation Ratio Calculation (SAR1 + SAR2)1.5/Ri  0.04 rounded to two digits The main WLAN antenna is located on the top side 126.2 mm from the left side. This was the value used for the
distance between the two antennas for the calculation. See the antenna locations on page 36.

SAR Data Summary ­ Simultaneous Transmit (WWAN-WLAN Secondary)

MEASUREMENT RESULTS

Plot

Position SAR (W/kg) WLAN SAR (W/kg) WWAN

Total SAR (W/kg)

-----

Back

0.13

0.47

0.06

-----

Left

1.09

1.53

2.62

-----

Top

0.40

0.26

0.66

Head 1.6 W/kg (mW/g) averaged over 1 gram
The WLAN Top side SAR value was calculated per KDB447498 D01 v06 section 4.3.2 b) 1). The antenna is more than 50 mm from the top side; therefore, the SAR value is set at 0.4 W/kg.

MEASUREMENT RESULTS ­ WWAN-WiFi (Main)

Position Left

Frequency

MHz Ch.

2462

11

X -0.05

Maxima
Y -71.97

Z -1.24

Frequency

MHz 846.4

Ch. 4233

Left ­ 102.1 mm

SPLSR=0.04

Simultaneous Separation Ratio Calculation

(SAR1 + SAR2)1.5/Ri  0.04 rounded to two digits

Maxima

X

Y

4.00

30.00

Z -0.06

SAR1 1.09

SAR2 1.53

SAR Total 2.62

Head Tissue 1.6 W/kg (mW/g) averaged over 1 gram

© 2022 RF Exposure Lab, LLC

Page 176 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

11. Test Equipment List

Report Number: SAR.20220203

Table 11.1 Equipment Specifications

Type

Calibration Due Date Calibration Done Date

Staubli Robot TX60L Measurement Controller CS8c ELI4 Flat Phantom ELI5 Flat Phantom Device Holder Data Acquisition Electronics 4 Data Acquisition Electronics 4 Data Acquisition Electronics 4 SPEAG E-Field Probe EX3DV4 SPEAG E-Field Probe EX3DV4 SPEAG E-Field Probe EX3DV4 Speag Validation Dipole D750V3 Speag Validation Dipole D900V2 Speag Validation Dipole D1750V2 Speag Validation Dipole D1900V2 Speag Validation Dipole D2550V2 Speag Validation Dipole D3500V2 Speag Validation Dipole D3700V2 Speag Validation Dipole D2450V2 Speag Validation Dipole D5GHzV2 Agilent N1911A Power Meter Agilent N1922A Power Sensor Agilent (HP) 8561E Spectrum Analyzer Agilent (HP) 8350B Signal Generator Agilent (HP) 83525A RF Plug-In Agilent (HP) 8753C Vector Network Analyzer Agilent (HP) 85047A S-Parameter Test Set Anritsu MT8820C Agilent N1911A Power Meter Agilent N1922A Power Sensor Agilent (HP) 8561E Spectrum Analyzer Agilent (HP) 83752A Synthesized Sweeper Agilent (HP) 8753C Vector Network Analyzer Agilent (HP) 85047A S-Parameter Test Set Agilent 778D Dual Directional Coupler Anritsu MT8820C Aprel Dielectric Probe Assembly Head Equivalent Matter (600 MHz) Head Equivalent Matter (750 MHz) Head Equivalent Matter (900 MHz) Head Equivalent Matter (1750 MHz) Head Equivalent Matter (1900 MHz) Head Equivalent Matter (2450 MHz) Head Equivalent Matter (2550 MHz) Head Equivalent Matter (3-6 GHz)

N/A N/A N/A N/A N/A 01/12/2023 04/22/2022 01/17/2024 01/14/2023 04/16/2022 04/12/2023 06/04/2023 06/04/2023 06/03/2022 06/04/2022 06/03/2022 04/13/2022 04/13/2022 06/03/2022 06/08/2022 03/16/2022 03/17/2022 03/15/2022 03/16/2022 03/16/2022 03/15/2022 03/15/2022 04/23/2022 03/16/2023 03/17/2023 03/17/2023 03/17/2023 03/17/2023 03/16/2023 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A 01/12/2022 04/22/2021 01/17/2023 01/14/2022 04/16/2021 04/12/2022 06/04/2021 06/04/2021 06/03/2021 06/04/2021 06/03/2021 04/13/2021 04/13/2021 06/03/2021 06/08/2021 03/16/2021 03/17/2021 03/15/2021 03/16/2021 03/16/2021 03/15/2021 03/15/2021 04/23/2021 03/16/2022 03/17/2022 03/17/2022 03/17/2022 03/17/2022 03/16/2022 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Serial Number
F07/55M6A1/A/01 1012 1065 2037 N/A 1321 1416 1321 7530 7531 7531 1053 1d128 1061 5d147 1003 1061 1024 881 1119 GB45100254 MY45240464 31720068 2749A10226 2647A01172 3135A01724 2904A00595 6201381721 GB45100254 MY45240464 31720068 3610A01048 3135A01724 2904A00595 MY48220184 6201381721 0011 N/A N/A N/A N/A N/A N/A N/A N/A

© 2022 RF Exposure Lab, LLC

Page 177 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
12. Conclusion
The SAR measurement indicates that the EUT complies with the RF radiation exposure limits of the FCC/IC. These measurements are taken to simulate the RF effects exposure under worst-case conditions. Precise laboratory measures were taken to assure repeatability of the tests. The tested device complies with the requirements in respect to all parameters subject to the test. The test results and statements relate only to the item(s) tested.
Please note that the absorption and distribution of electromagnetic energy in the body is a very complex phenomena that depends on the mass, shape, and size of the body; the orientation of the body with respect to the field vectors; and, the electrical properties of both the body and the environment. Other variables that may play a substantial role in possible biological effects are those that characterize the environment (e.g. ambient temperature, air velocity, relative humidity, and body insulation) and those that characterize the individual (e.g. age, gender, activity level, debilitation, or disease). Because innumerable factors may interact to determine the specific biological outcome of an exposure to electromagnetic fields, any protection guide shall consider maximal amplification of biological effects as a result of field-body interactions, environmental conditions, and physiological variables.

© 2022 RF Exposure Lab, LLC

Page 178 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
13. References
[1] Federal Communications Commission, ET Docket 93-62, Guidelines for Evaluating the Environmental Effects of Radio Frequency Radiation, August 1996
[2] ANSI/IEEE C95.1 ­ 1992, American National Standard Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 300kHz to 100GHz, New York: IEEE, 1992.
[3] ANSI/IEEE C95.3 ­ 1992, IEEE Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields ­ RF and Microwave, New York: IEEE, 1992.
[4] International Electrotechnical Commission, IEC 62209-2 (Edition 1.0), Human Exposure to radio frequency fields from hand-held and body mounted wireless communication devices ­ Human models, instrumentation, and procedures ­ Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz), March 2010.
[5] IEEE Standard 1528 ­ 2013, IEEE Recommended Practice for Determining the Peak-Spatial Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communication Devices: Measurement Techniques, June 2013.
[6] Industry Canada, RSS ­ 102 Issue 5, Radio Frequency Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands), March 2015.
[7] Health Canada, Safety Code 6, Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3kHz to 300 GHz, 2009.

© 2022 RF Exposure Lab, LLC

Page 179 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

Appendix A ­ System Validation Plots and Data

************************************************************

Test Result for UIM Dielectric Parameter

Mon 20/Feb/2023

Freq Frequency(GHz)

FCC_eH Limits for Head Epsilon

FCC_sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

FCC_eH FCC_sH Test_e Test_s

0.6500

42.46 0.88 41.86 0.84

0.6600

42.41 0.88 41.81 0.84

0.6700

42.36 0.89 41.75 0.85

0.6730

42.345 0.89 41.732 0.85*

0.6800

42.31 0.89 41.69 0.85

0.6805

42.307 0.89 41.687 0.851*

0.6880

42.262 0.89 41.642 0.858*

0.6900

42.25 0.89 41.63 0.86

0.7000

42.20 0.89 41.78 0.86

0.7000

42.20 0.89 41.76 0.86

0.7040

42.18 0.89 41.732 0.864*

0.7075

42.163 0.89 41.708 0.868*

0.7100

42.15 0.89 41.69 0.87

0.7110

42.145 0.89 41.685 0.871*

0.7200

42.10 0.89 41.64 0.88

0.7300

42.05 0.89 41.57 0.89

0.7400

41.99 0.89 41.51 0.89

0.7500

41.94 0.89 41.46 0.90

0.7600

41.89 0.89 41.40 0.91

0.7700

41.84 0.89 41.34 0.92

0.7800

41.79 0.90 41.28 0.92

0.7820

41.778 0.90 41.268 0.922*

0.7900

41.73 0.90 41.22 0.93

0.7930

41.715 0.90 41.208 0.93*

0.8000

41.68 0.90 41.18 0.93

* value interpolated

© 2022 RF Exposure Lab, LLC

Page 180 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

************************************************************

Test Result for UIM Dielectric Parameter

Fri 17/Feb/2023

Freq Frequency(GHz)

eH Limits for Head Epsilon

sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

eH

sH

Test_e Test_s

0.8000

41.68 0.90 41.52 0.89

0.8100

41.63 0.90 41.47 0.90

0.8200

41.58 0.90 41.41 0.91

0.8215

41.573 0.90 41.418 0.91*

0.8264

41.548 0.90 41.442 0.91*

0.8300

41.53 0.90 41.46 0.91

0.8315

41.526 0.902 41.456 0.912*

0.8366

41.51 0.907 41.44 0.917*

0.8400

41.50 0.91 41.43 0.92

0.8415

41.50 0.912 41.427 0.922*

0.8466

41.50 0.917 41.417 0.927*

0.8500

41.50 0.92 41.41 0.93

0.8600

41.50 0.93 41.39 0.94

0.8700

41.50 0.94 41.37 0.95

0.8800

41.50 0.95 41.36 0.96

0.8900

41.50 0.96 41.35 0.97

0.9000

41.50 0.97 41.34 0.98

0.9100

41.50 0.98 41.33 0.99

0.9200

41.49 0.98 41.32 0.99

* value interpolated

************************************************************

Test Result for UIM Dielectric Parameter

Mon 31/Jan/2022

Freq Frequency(GHz)

eH Limits for Head Epsilon

sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

eH

sH

Test_e Test_s

1.7000

40.16 1.34 39.34 1.36

1.7100

40.14 1.35 39.32 1.37

1.7124

40.138 1.35 39.315 1.372*

1.7200

40.13 1.35 39.30 1.38

1.7300

40.11 1.36 39.28 1.38

1.7326

40.105 1.363 39.275 1.383*

1.7400

40.09 1.37 39.26 1.39

1.7450

40.085 1.37 39.25 1.395*

1.7500

40.08 1.37 39.24 1.40

1.7526

40.075 1.373 39.235 1.403*

1.7600

40.06 1.38 39.22 1.41

1.7700

40.05 1.38 39.20 1.42

1.7800

40.03 1.39 39.18 1.42

1.7900

40.02 1.39 39.16 1.43

* value interpolated

© 2022 RF Exposure Lab, LLC

Page 181 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

************************************************************

Test Result for UIM Dielectric Parameter

Fri 28/Jan/2022

Freq Frequency(GHz)

eH Limits for Head Epsilon

sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

eH

sH

Test_e Test_s

1.8500

40.00 1.40 39.97 1.37

1.8524

40.00 1.40 39.65 1.372*

1.8600

40.00 1.40 39.95 1.38

1.8700

40.00 1.40 39.93 1.38

1.8800

40.00 1.40 39.91 1.39

1.8825

40.00 1.40 39.905 1.39*

1.8900

40.00 1.40 39.89 1.39

1.9000

40.00 1.40 39.87 1.39

1.9050

40.00 1.40 39.86 1.395*

1.9076

40.00 1.40 39.855 1.398*

1.9100

40.00 1.40 39.85 1.40

1.9200

40.00 1.40 39.84 1.41

* value interpolated

************************************************************

Test Result for UIM Dielectric Parameter

Thu 27/Jan/2022

Freq Frequency(GHz)

FCC_eH Limits for Head Epsilon

FCC_sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

FCC_eH FCC_sH Test_e Test_s

2.4900

39.15 1.84 39.09 1.86

2.5000

39.14 1.85 39.07 1.87

2.5060

39.128 1.862 39.052 1.876*

2.5100

39.12 1.87 39.04 1.88

2.5200

39.11 1.88 39.02 1.90

2.5300

39.10 1.89 39.00 1.91

2.5350

39.095 1.895 38.985 1.915*

2.5400

39.09 1.90 38.97 1.92

2.5445

39.081 1.905 38.961 1.929*

2.5500

39.07 1.91 38.95 1.94*

2.5600

39.06 1.92 38.93 1.95

2.5700

39.05 1.93 38.90 1.96

2.5800

39.03 1.94 38.88 1.98

2.5900

39.02 1.95 38.85 1.99

2.5930

39.017 1.953 38.853 1.99*

2.6000

39.01 1.96 38.86 1.99

2.6100

39.00 1.97 38.84 2.00

2.6200

38.98 1.99 38.83 2.01

2.6300

38.97 2.00 38.81 2.02

2.6400

38.96 2.01 38.79 2.03

2.6415

38.959 2.012 38.787 2.032*

2.6500

38.95 2.02 38.77 2.04

2.6600

38.93 2.03 38.76 2.05

2.6700

38.92 2.04 38.74 2.06

2.6800

38.91 2.05 38.72 2.07

2.6900

38.89 2.06 38.70 2.08

2.7000

38.88 2.07 38.69 2.09

* value interpolated

© 2022 RF Exposure Lab, LLC

Page 182 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

************************************************************

Test Result for UIM Dielectric Parameter

Tue 01/Feb/2022

Freq Frequency(GHz)

FCC_eH Limits for Head Epsilon

FCC_sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

FCC_eH FCC_sH Test_e Test_s

3.3800

38.07 2.79 37.25 2.84

3.3900

38.05 2.80 37.23 2.85

3.4000

38.04 2.81 37.21 2.86

3.4100

38.03 2.82 37.19 2.87

3.4200

38.02 2.83 37.18 2.88

3.4300

38.01 2.84 37.16 2.89

3.4400

38.00 2.85 37.14 2.90

3.4550

37.985 2.865 37.11 2.915*

3.4500

37.99 2.86 37.12 2.91

3.4600

37.97 2.87 37.10 2.92

3.4700

37.96 2.88 37.07 2.93

3.4800

37.95 2.89 37.05 2.94

3.4900

37.94 2.90 37.03 2.95

3.5000

37.93 2.91 37.00 2.96

3.5100

37.92 2.92 36.98 2.97

3.5200

37.91 2.93 36.96 2.98

3.5300

37.89 2.94 36.93 2.99

3.5400

37.88 2.95 36.90 3.84

3.5450

37.875 2.955 36.885 3.85*

3.5500

37.87 2.96 36.87 3.86

3.5600

37.86 2.97 36.85 3.88

3.5700

37.85 2.98 36.83 3.91

3.5800

37.84 2.99 36.81 3.93

3.5900

37.83 3.00 36.78 3.95

3.5925

37.825 3.005 36.775 3.955*

3.6000

37.81 3.02 36.76 3.97

3.6100

37.80 3.03 36.74 3.00

3.6200

37.79 3.04 36.73 3.01

3.6250

37.785 3.045 36.715 3.015*

3.6300

37.78 3.05 36.70 3.02

3.6400

37.77 3.06 36.67 3.03

3.6500

37.76 3.07 36.64 3.04

3.6575

37.753 3.078 36.625 3.048*

3.6600

37.75 3.08 36.62 3.05

3.6700

37.73 3.09 36.60 3.06

3.6800

37.72 3.10 36.58 3.07

3.6900

37.71 3.11 36.55 3.08

3.7000

37.70 3.12 36.53 3.09

3.7100

37.69 3.13 36.50 3.10

3.7200

37.68 3.14 36.48 3.11

* value interpolated

© 2022 RF Exposure Lab, LLC

Page 183 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

************************************************************

Test Result for UIM Dielectric Parameter

Thu 03/Feb/2022

Freq Frequency(GHz)

FCC_eH Limits for Head Epsilon

FCC_sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

FCC_eH FCC_sH Test_e Test_s

2.4100

39.26 1.76 38.44 1.76

2.4120

39.258 1.762 38.436 1.762*

2.4200

39.25 1.77 38.42 1.77

2.4300

39.24 1.78 38.40 1.78

2.4370

39.226 1.787 38.393 1.794*

2.4400

39.22 1.79 38.39 1.80

2.4420

39.216 1.792 38.38 1.802*

2.4500

39.20 1.80 38.34 1.81

2.4600

39.19 1.81 38.34 1.82

2.4620

39.186 1.812 38.336 1.822*

2.4700

39.17 1.82 38.32 1.83

2.4720

39.168 1.822 38.316 1.836*

2.4800

39.16 1.83 38.30 1.86

* value interpolated

© 2022 RF Exposure Lab, LLC

Page 184 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

************************************************************

Test Result for UIM Dielectric Parameter

Fri 04/Feb/2022

Freq Frequency(GHz)

FCC_eH Limits for Head Epsilon

FCC_sH Limits for Head Sigma

Test_e Epsilon of UIM

Test_s Sigma of UIM

************************************************************

Freq

FCC_eH FCC_sH Test_e Test_s

5.1000

36.10 4.55 34.94 4.56

5.1200

36.08 4.57 34.92 4.58

5.1400

36.05 4.59 34.89 4.60

5.1600

36.03 4.61 34.87 4.63

5.1800

36.01 4.63 34.85 4.65

5.2000

35.99 4.65 34.82 4.67

5.2200

35.96 4.68 34.80 4.69

5.2400

35.94 4.70 34.78 4.71

5.2500

35.93 4.71 34.765 4.725*

5.2600

35.92 4.72 34.75 4.74

5.2800

35.89 4.74 34.72 4.76

5.3000

35.87 4.76 34.69 4.78

5.3200

35.85 4.78 34.67 4.80

5.3400

35.83 4.80 34.65 4.83

5.3600

35.80 4.82 34.63 4.85

5.3800

35.78 4.84 34.60 4.87

5.4000

35.76 4.86 34.58 4.89

5.4200

35.73 4.88 34.56 4.92

5.4400

35.71 4.90 34.55 4.94

5.4600

35.69 4.92 34.52 4.96

5.4800

35.67 4.94 34.49 4.98

5.5000

35.64 4.96 34.46 5.00

5.5200

35.62 4.98 34.44 5.02

5.5400

35.60 5.00 34.42 5.04

5.5600

35.57 5.02 34.40 5.07

5.5800

35.55 5.04 34.37 5.09

5.6000

35.53 5.07 34.35 5.11

5.6200

35.51 5.09 34.32 5.13

5.6400

35.48 5.11 34.30 5.16

5.6600

35.46 5.13 34.28 5.18

5.6800

35.44 5.15 34.26 5.20

5.7000

35.41 5.17 34.23 5.22

5.7200

35.39 5.19 34.21 5.25

5.7400

35.37 5.21 34.19 5.27

5.7450

35.365 5.215 34.185 5.275*

5.7500

35.36 5.22 34.18 5.28*

5.7600

35.35 5.23 34.17 5.29

5.7800

35.32 5.25 34.15 5.31

5.7850

35.315 5.255 34.14 5.315*

5.8000

35.30 5.27 34.11 5.33

5.8200

35.28 5.29 34.09 5.36

5.8250

35.273 5.295 34.085 5.365*

5.8400

35.25 5.31 34.07 5.38

5.8600

35.23 5.33 34.05 5.40

* value interpolated

© 2022 RF Exposure Lab, LLC

Page 185 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 1
DUT: Dipole 750 MHz D750V3; Type: D750V3; Serial: D750V3 - SN 1053
Communication System: CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: HSL750; Medium parameters used (interpolated): f = 750 MHz;  = 0.9 S/m; r = 41.46;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/20/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7531; ConvF(10.75, 10.75, 10.75); Calibrated: 4/12/2022; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 1251 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
750 MHz Head/Verification/Area Scan (41x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 0.883 W/kg
750 MHz Head/Verification /Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 31.949 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.691 mW/g Pin= 100 mW SAR(1 g) = 0.858 mW/g; SAR(10 g) = 0.552 mW/g Maximum value of SAR (measured) = 0.888 W/kg

© 2022 RF Exposure Lab, LLC

Page 186 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 2
DUT: Dipole 900 MHz D900V2; Type: D900V2; Serial: D900V2 - SN:1d128
Communication System: CW; Frequency: 900 MHz; Duty Cycle: 1:1 Medium: HSL900; Medium parameters used: f = 900 MHz;  = 0.98 S/m; r = 41.34;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/17/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7531; ConvF(10.33, 10.33, 10.33); Calibrated: 4/12/2022; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 1251 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
900 MHz Head/Verification/Area Scan (5x11x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.19 W/kg
900 MHz Head/Verification/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 31.568 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 1.43 W/kg Pin= 100 mW SAR(1 g) = 1.15 W/kg; SAR(10 g) = 0.712 W/kg Maximum value of SAR (measured) = 1.2 W/kg

© 2022 RF Exposure Lab, LLC

Page 187 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 3
DUT: Dipole 1750 MHz D1750V2; Type: D1750V2; Serial: D1750V2 - SN:1061
Communication System: CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: HSL1750; Medium parameters used: f = 1750 MHz;  = 1.4 S/m; r = 39.24;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/31/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 - SN7531; ConvF(8.57, 8.57, 8.57); Calibrated: 4/16/2021; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
1750 MHz/Verification/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 5.38 W/kg
1750 MHz/Verification/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 33.639 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 6.87 W/kg Pin= 100 mW SAR(1 g) = 3.78 W/kg; SAR(10 g) = 1.97 W/kg Maximum value of SAR (measured) = 5.47 W/kg

© 2022 RF Exposure Lab, LLC

Page 188 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 4
DUT: Dipole 1900 MHz D1900V2; Type: D1900V2; Serial: D1900V2 - SN: 5d147
Communication System: CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: HSL1950; Medium parameters used: f = 1900 MHz;  = 1.39 S/m; r = 39.87;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/28/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 - SN7531; ConvF(8.05, 8.05, 8.05); Calibrated: 4/16/2021; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
1900 MHz/Verification/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 5.52 W/kg
1900 MHz/Verification/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 32.186 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 7.25 W/kg Pin= 100 mW SAR(1 g) = 4.15 W/kg; SAR(10 g) = 2.16 W/kg Maximum value of SAR (measured) = 5.79 W/kg

© 2022 RF Exposure Lab, LLC

Page 189 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 5
DUT: Dipole 2550 MHz D2550V2; Type: D2550V2; Serial: D2550V2 - SN:1003
Communication System: CW; Frequency: 2550 MHz; Duty Cycle: 1:1 Medium: HSL2550; Medium parameters used: f = 2550 MHz;  = 1.94 S/m; r = 38.95;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/27/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 - SN7531; ConvF(7.3, 7.3, 7.3); Calibrated: 4/16/2021; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
2550 MHz Body/Verification/Area Scan (61x81x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 9.18 W/kg
2550 MHz Body/Verification/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 54.541 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 11.5 W/kg Pin= 100 mW SAR(1 g) = 5.64 W/kg; SAR(10 g) = 2.48 W/kg Maximum value of SAR (measured) = 8.98 W/kg

© 2022 RF Exposure Lab, LLC

Page 190 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 6
DUT: Dipole D3500V2; Type: D3500V2; Serial: D3500V2 - SN: 1061
Communication System: CW; Frequency: 3500 MHz; Duty Cycle: 1:1 Medium: HSL 3-6 GHz; Medium parameters used: f = 3500 MHz;  = 2.96 S/m; r = 37;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/1/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 - SN7531; ConvF(6.8, 6.8, 6.8); Calibrated: 4/16/2021; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
3500 MHz Head/Verification/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 1.62 W/kg
3500 MHz Head/Verification/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=4mm Reference Value = 52.432 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 3.64 W/kg Pin= 10 mW SAR(1 g) = 0.678 W/kg; SAR(10 g) = 0.256 W/kg Maximum value of SAR (measured) = 1.68 W/kg

© 2022 RF Exposure Lab, LLC

Page 191 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 7
DUT: Dipole D3700V2; Type: D3700V2; Serial: D3700V2 - SN:1024
Communication System: CW; Frequency: 3700 MHz; Duty Cycle: 1:1 Medium: HSL 3-6 GHz; Medium parameters used: f = 3700 MHz;  = 3.09 S/m; r = 36.53;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/1/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7531; ConvF(6.4, 6.4, 6.4); Calibrated: 4/16/2021; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
3700 MHz Head/Verification/Area Scan (61x81x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 1.63 W/kg
3700 MHz Head/Verification/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 54.976 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 3.35 W/kg Pin= 10 mW SAR(1 g) = 0.695 W/kg; SAR(10 g) = 0.252 W/kg Maximum value of SAR (measured) = 1.71 W/kg

© 2022 RF Exposure Lab, LLC

Page 192 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 8
DUT: Dipole 2450 MHz D2450V2; Type: D2450V2; Serial: D2450V2 - SN: 881
Communication System: CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: HSL2450; Medium parameters used: f = 2450 MHz;  = 1.81 S/m; r = 38.34;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/3/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7530; ConvF(7.65, 7.65, 7.65); Calibrated: 1/14/2022; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
Head Verification/2450 MHz/Area Scan (61x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 8.22 W/kg
Head Verification/2450 MHz/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 56.025 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 11.05 W/kg Pin= 100 mW SAR(1 g) = 5.46 W/kg; SAR(10 g) = 2.52 W/kg Maximum value of SAR (measured) = 8.96 W/kg

© 2022 RF Exposure Lab, LLC

Page 193 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 9
DUT: Dipole D5GHzV2; Type: D5GHzV2; Serial: D5GHzV2 - SN: 1119
Communication System: CW; Frequency: 5250 MHz; Duty Cycle: 1:1 Medium: HSL 3-6 GHz; Medium parameters used (interpolated): f = 5250 MHz;  = 4.725 S/m; r = 34.765;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/4/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7530; ConvF(5.45, 5.45, 5.45); Calibrated: 1/14/2022; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
Head Verification/5250 MHz/Area Scan (61x81x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (interpolated) = 1.47 W/kg
Head Verification/5250 MHz/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 15.267 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 3.22 W/kg Pin=10 mW SAR(1 g) = 0.803 W/kg; SAR(10 g) = 0.226 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.88 W/kg

© 2022 RF Exposure Lab, LLC

Page 194 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 10
DUT: Dipole D5GHzV2; Type: D5GHzV2; Serial: D5GHzV2 - SN: 1119
Communication System: CW; Frequency: 5600 MHz; Duty Cycle: 1:1 Medium: HSL 3-6 GHz; Medium parameters used: f = 5600 MHz;  = 5.11 S/m; r = 34.35;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/4/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7530; ConvF(4.8, 4.8, 4.8); Calibrated: 1/14/2022; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
Head Verification/5600 MHz/Area Scan (61x81x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 1.72 W/kg
Head Verification/5600 MHz/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 15.398 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 3.59 W/kg Pin=10 mW SAR(1 g) = 0.835 W/kg; SAR(10 g) = 0.241 W/kg Maximum value of SAR (measured) = 2.01 W/kg

© 2022 RF Exposure Lab, LLC

Page 195 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 11
DUT: Dipole D5GHzV2; Type: D5GHzV2; Serial: D5GHzV2 - SN: 1119
Communication System: CW; Frequency: 5750 MHz; Duty Cycle: 1:1 Medium: HSL 3-6 GHz; Medium parameters used (interpolated): f = 5750 MHz;  = 5.28 S/m; r = 34.18;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/4/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C Probe: EX3DV4 ­ SN7530; ConvF(4.98, 4.98, 4.98); Calibrated: 1/14/2022; Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
Head Verification/5750 MHz/Area Scan (61x81x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (interpolated) = 1.61 W/kg
Head Verification/5750 MHz/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 14.521 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 2.34 W/kg Pin=10 mW SAR(1 g) = 0.805 W/kg; SAR(10 g) = 0.233 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.78 W/kg

© 2022 RF Exposure Lab, LLC

Page 196 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Appendix B ­ SAR Test Data Plots

© 2022 RF Exposure Lab, LLC

Page 197 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 1
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 680.5 MHz; Duty Cycle: 1:1 Medium: HSL750; Medium parameters used (interpolated): f = 680.5 MHz;  = 0.851 S/m; r = 41.687;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/20/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 ­ SN7531; ConvF(10.75, 10.75, 10.75); Calibrated: 4/12/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B71 LTE/Left Mid 1 RB 24 Offset/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.17 W/kg
B71 LTE/Left Mid 1 RB 24 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.698 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 1.31 W/kg SAR(1 g) = 1.04 W/kg; SAR(10 g) = 0.721 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.09 W/kg

© 2022 RF Exposure Lab, LLC

Page 198 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 2
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 10 MHz, QPSK); Frequency: 711 MHz; Duty Cycle: 1:1 Medium: HSL750; Medium parameters used (interpolated): f = 711 MHz;  = 0.871 S/m; r = 41.685;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/20/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 ­ SN7531; ConvF(10.75, 10.75, 10.75); Calibrated: 4/12/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B12 LTE/Left High 1 RB 24 Offset/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.74 W/kg
B12 LTE/Left High 1 RB 24 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 11.17 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 2.09 W/kg SAR(1 g) = 1.23 W/kg; SAR(10 g) = 0.825 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.83 W/kg

© 2022 RF Exposure Lab, LLC

Page 199 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 3
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 10 MHz, QPSK); Frequency: 782 MHz; Duty Cycle: 1:1 Medium: HSL750; Medium parameters used (interpolated): f = 782 MHz;  = 0.922 S/m; r = 41.268;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/21/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 ­ SN7531; ConvF(10.75, 10.75, 10.75); Calibrated: 4/12/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B13 LTE/Left Mid 1RB 24 Offset/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.52 W/kg
B13 LTE/Left Mid 1RB 24 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.903 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 1.78 W/kg SAR(1 g) = 1.16 W/kg; SAR(10 g) = 0.712 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.55 W/kg

© 2022 RF Exposure Lab, LLC

Page 200 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 4
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 10 MHz, QPSK); Frequency: 793 MHz; Duty Cycle: 1:1 Medium: HSL750; Medium parameters used (interpolated): f = 793 MHz;  = 0.93 S/m; r = 41.208;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/21/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 ­ SN7531; ConvF(10.75, 10.75, 10.75); Calibrated: 4/12/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B14 LTE/Left Mid 1RB 24 Offset/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.80 W/kg
B14 LTE/Left Mid 1RB 24 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 9.193 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 2.15 W/kg SAR(1 g) = 1.37 W/kg; SAR(10 g) = 0.851 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.87 W/kg

© 2022 RF Exposure Lab, LLC

Page 201 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 5
DUT: ST1; Type: Tablet; Serial: 014
Communication System: UMTS (WCDMA); Frequency: 846.6 MHz; Duty Cycle: 1:1 Medium: HSL835; Medium parameters used (interpolated): f = 846.6 MHz;  = 0.927 S/m; r = 41.417;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/17/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 ­ SN7531; ConvF(10.33, 10.33, 10.33); Calibrated: 4/12/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B5 WCDMA/Left High/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.40 W/kg
B5 WCDMA/Left High/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.418 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 1.82 W/kg SAR(1 g) = 1.20 W/kg; SAR(10 g) = 0.723 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.60 W/kg

© 2022 RF Exposure Lab, LLC

Page 202 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 6
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 15 MHz, QPSK); Frequency: 821.5 MHz; Duty Cycle: 1:1 Medium: HSL835; Medium parameters used (interpolated): f = 821.5 MHz;  = 0.91 S/m; r = 41.418;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/17/2023; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 ­ SN7531; ConvF(10.33, 10.33, 10.33); Calibrated: 4/12/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/17/2023 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B26 LTE/Left Low 1 RB 37 Offset/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.74 W/kg
B26 LTE/Left Low 1 RB 37 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 8.033 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 2.03 W/kg SAR(1 g) = 1.21 W/kg; SAR(10 g) = 0.787 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.76 W/kg

© 2022 RF Exposure Lab, LLC

Page 203 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 7
DUT: ST1; Type: Tablet; Serial: 014
Communication System: UMTS (WCDMA); Frequency: 1752.6 MHz; Duty Cycle: 1:1 Medium: HSL1750; Medium parameters used (interpolated): f = 1752.6 MHz;  = 1.403 S/m; r = 39.235;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/31/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(8.57, 8.57, 8.57); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B4 WCDMA/Left High/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.65 W/kg
B4 WCDMA/Left High/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.03 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 2.08 W/kg SAR(1 g) = 1.04 W/kg; SAR(10 g) = 0.529 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.63 W/kg
B4 WCDMA/Left High/Zoom Scan (5x5x7)/Cube 1: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 10.03 V/m; Power Drift = -0.03 dB Peak SAR (extrapolated) = 1.17 W/kg SAR(1 g) = 0.822 W/kg; SAR(10 g) = 0.385 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.806 W/kg

© 2022 RF Exposure Lab, LLC

Page 204 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 8
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 1770 MHz; Duty Cycle: 1:1 Medium: HSL1750; Medium parameters used: f = 1770 MHz;  = 1.42 S/m; r = 39.2;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/31/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(8.57, 8.57, 8.57); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B66 LTE/Left High 1 RB 49 Offset/Area Scan (5x8x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 1.14 W/kg
B66 LTE/Left High 1 RB 49 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.517 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 1.80 W/kg SAR(1 g) = 1.08 W/kg; SAR(10 g) = 0.579 W/kg Maximum value of SAR (measured) = 1.28 W/kg
B66 LTE/Left High 1 RB 49 Offset/Zoom Scan (5x5x7)/Cube 1: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 5.517 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 0.924 W/kg SAR(1 g) = 0.544 W/kg; SAR(10 g) = 0.302 W/kg Maximum value of SAR (measured) = 0.606 W/kg

© 2022 RF Exposure Lab, LLC

Page 205 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 9
DUT: ST1; Type: Tablet; Serial: 014
Communication System: UMTS (WCDMA); Frequency: 1907.6 MHz; Duty Cycle: 1:1 Medium: HSL1900; Medium parameters used (interpolated): f = 1907.6 MHz;  = 1.398 S/m; r = 39.855;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/28/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(8.05, 8.05, 8.05); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B2 WCDMA/Left High/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.75 W/kg
B2 WCDMA/Left High/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 3.366 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 2.30 W/kg SAR(1 g) = 1.09 W/kg; SAR(10 g) = 0.554 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.75 W/kg

© 2022 RF Exposure Lab, LLC

Page 206 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 10
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 1882.5 MHz; Duty Cycle: 1:1 Medium: HSL1900; Medium parameters used (interpolated): f = 1882.5 MHz;  = 1.39 S/m; r = 39.905;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/28/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(8.05, 8.05, 8.05); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B25 LTE/Left Mid 1 RB 49 Offset/Area Scan (5x7x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.04 W/kg
B25 LTE/Left Mid 1 RB 49 Offset/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 4.053 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 2.03 W/kg SAR(1 g) = 1.04 W/kg; SAR(10 g) = 0.478 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.45 W/kg

© 2022 RF Exposure Lab, LLC

Page 207 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 11
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 2535 MHz; Duty Cycle: 1:1 Medium: HSL2550; Medium parameters used (interpolated): f = 2535 MHz;  = 1.915 S/m; r = 38.985;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/27/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(7.3, 7.3, 7.3); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B7 LTE/Left 1 RB 49 Offset Mid/Area Scan (7x10x1): Measurement grid: dx=10mm, dy=10mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.30 W/kg
B7 LTE/Left 1 RB 49 Offset Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.364 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 2.05 W/kg SAR(1 g) = 1.09 W/kg; SAR(10 g) = 0.414 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.49 W/kg

© 2022 RF Exposure Lab, LLC

Page 208 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 12
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 2593 MHz; Duty Cycle: 1:1 Medium: HSL2550; Medium parameters used (interpolated): f = 2593 MHz;  = 1.99 S/m; r = 38.853;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 1/27/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(7.3, 7.3, 7.3); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B41 LTE/Left 1 RB 49 Offset Mid/Area Scan (7x10x1): Measurement grid: dx=10mm, dy=10mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.44 W/kg
B41 LTE/Left 1 RB 49 Offset Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.282 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 1.28 W/kg SAR(1 g) = 1.01 W/kg; SAR(10 g) = 0.446 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.44 W/kg

© 2022 RF Exposure Lab, LLC

Page 209 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 13
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 3500 MHz; Duty Cycle: 1:1 Medium: HSL3-6GHz; Medium parameters used: f = 3500 MHz;  = 2.96 S/m; r = 37;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/1/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(6.8, 6.8, 6.8); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B42 LTE/Left 1 RB 49 Offset Mid/Area Scan (7x10x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 0.827 W/kg
B42 LTE/Left 1 RB 49 Offset Mid/Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=4mm Reference Value = 3.153 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 1.89 W/kg SAR(1 g) = 0.999 W/kg; SAR(10 g) = 0.336 W/kg Maximum value of SAR (measured) = 1.06 W/kg

© 2022 RF Exposure Lab, LLC

Page 210 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 14
DUT: ST1; Type: Tablet; Serial: 014
Communication System: LTE (SC-FDMA, 1 RB, 20 MHz, QPSK); Frequency: 3625 MHz; Duty Cycle: 1:1 Medium: HSL3-6GHz; Medium parameters used (interpolated): f = 3625 MHz;  = 3.015 S/m; r = 36.715;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/1/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7531; ConvF(6.4, 6.4, 6.4); Calibrated: 4/16/2021 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1321; Calibrated: 1/12/2022 Phantom: ELI v4.0; Type: QDOVA001BB; Serial: 1065 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
B48 LTE/Left 1 RB 49 Offset Mid/Area Scan (7x10x1): Measurement grid: dx=10mm, dy=10mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.840 W/kg
B48 LTE/Left 1 RB 49 Offset Mid/Zoom Scan (7x7x8)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=4mm Reference Value = 3.855 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 1.67 W/kg SAR(1 g) = 1.08 W/kg; SAR(10 g) = 0.341 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.09 W/kg

© 2022 RF Exposure Lab, LLC

Page 211 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 15
DUT: ST1; Type: Tablet; Serial: 014
Communication System: WiFi 802.11b (DSSS, 1 Mbps); Frequency: 2462 MHz; Duty Cycle: 1:1 Medium: HSL2450; Medium parameters used (interpolated): f = 2462 MHz;  = 1.822 S/m; r = 38.336;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/3/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7530; ConvF(7.65, 7.65, 7.65); Calibrated: 1/14/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
2.4 GHz/Secondary Left 11/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.72 W/kg
2.4 GHz/Secondary Left 11/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 1.841 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 3.04 W/kg SAR(1 g) = 1.08 W/kg; SAR(10 g) = 0.426 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 1.72 W/kg

© 2022 RF Exposure Lab, LLC

Page 212 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 16
DUT: ST1; Type: Tablet; Serial: 014
Communication System: WiFi 802.11a (OFDM, 6 Mbps); Frequency: 5300 MHz; Duty Cycle: 1:1 Medium: HSL3-6GHz; Medium parameters used: f = 5300 MHz;  = 4.78 S/m; r = 34.69;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/4/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7530; ConvF(5.45, 5.45, 5.45); Calibrated: 1/14/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
5.2 GHz/Secondary Left 60/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 1.93 W/kg
5.2 GHz/Secondary Left 60/Zoom Scan (8x8x16)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 2.559 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 4.08 W/kg SAR(1 g) = 1.06 W/kg; SAR(10 g) = 0.379 W/kg Maximum value of SAR (measured) = 1.89 W/kg

© 2022 RF Exposure Lab, LLC

Page 213 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 17
DUT: ST1; Type: Tablet; Serial: 014
Communication System: WiFi 802.11a (OFDM, 6 Mbps); Frequency: 5620 MHz; Duty Cycle: 1:1 Medium: HSL3-6GHz; Medium parameters used: f = 5620 MHz;  = 5.13 S/m; r = 34.32;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/4/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7530; ConvF(4.8, 4.8, 4.8); Calibrated: 1/14/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
5.6 GHz/Primary Top 124/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 2.25 W/kg
5.6 GHz/Primary Top 124/Zoom Scan (8x8x16)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 9.255 V/m; Power Drift = 0.01 dB Peak SAR (extrapolated) = 4.88 W/kg SAR(1 g) = 1.09 W/kg; SAR(10 g) = 0.338 W/kg Maximum value of SAR (measured) = 2.34 W/kg

© 2022 RF Exposure Lab, LLC

Page 214 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
RF Exposure Lab
Plot 18
DUT: ST1; Type: Tablet; Serial: 014
Communication System: WiFi 802.11a (OFDM, 6 Mbps); Frequency: 5785 MHz; Duty Cycle: 1:1 Medium: HSL3-6GHz; Medium parameters used (interpolated): f = 5785 MHz;  = 5.315 S/m; r = 34.14;  = 1000 kg/m3 Phantom section: Flat Section
Test Date: Date: 2/4/2022; Ambient Temp: 23 °C; Tissue Temp: 21 °C
Probe: EX3DV4 - SN7530; ConvF(4.98, 4.98, 4.98); Calibrated: 1/14/2022 Sensor-Surface: 2mm (Mechanical Surface Detection) Electronics: DAE4 Sn1416; Calibrated: 4/22/2021 Phantom: ELI v5.0; Type: QDOVA002AA; Serial: 2037 Measurement SW: DASY52, Version 52.10 (0); SEMCAD X Version 14.6.10 (7417)
Procedure Notes:
5.8 GHz/Primary Top 157/Area Scan (7x9x1): Measurement grid: dx=10mm, dy=10mm
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 2.49 W/kg
5.8 GHz/Primary Top 157/Zoom Scan (9x9x16)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 10.39 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 6.51 W/kg SAR(1 g) = 1.06 W/kg; SAR(10 g) = 0.324 W/kg
Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 2.58 W/kg

© 2022 RF Exposure Lab, LLC

Page 215 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Appendix C ­ SAR Test Setup Photos

Test Position Back 0 mm Gap Note: Cables are removed prior to testing.

© 2022 RF Exposure Lab, LLC

Page 216 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

Test Position Left 0 mm Gap Note: Cables are removed prior to testing.

© 2022 RF Exposure Lab, LLC

Page 217 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

Test Position Top 0 mm Gap Note: Cables are removed prior to testing.

© 2022 RF Exposure Lab, LLC

Page 218 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Antenna Locations

© 2022 RF Exposure Lab, LLC

Page 219 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

Front of Device

© 2022 RF Exposure Lab, LLC

Page 220 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203

Back of Device

© 2022 RF Exposure Lab, LLC

Page 221 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Appendix D ­ Probe Calibration Data Sheets

© 2022 RF Exposure Lab, LLC

Page 222 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Appendix E ­ Dipole Calibration Data Sheets

© 2022 RF Exposure Lab, LLC

Page 267 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Appendix F ­ DAE Calibration Data Sheets

© 2022 RF Exposure Lab, LLC

Page 332 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Report Number: SAR.20220203
Appendix G ­ Phantom Calibration Data Sheets

© 2022 RF Exposure Lab, LLC

Page 348 of 349

This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.



Related FCC IDs: