it ste ir nditinin 4AC13L
13 SEER Split System Air Conditioner - Page 2 - Electrical and Physical Data † Overcurrent protection device † † Factory charge adequate for 15 feet of line set. Adjust per Installation Instructions.
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 24 Pages, 807.22KB
Document DEVICE REPORTArmstrong 4AC13L Tech Spec a4ac13l-1004AC13L Features and Benefits · R410a Refrigerant · High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity · Top discharge directs hot air away from living area and shrubbery · All units factory run tested · Available with louvered panel coil protection option · Easy access to electrical panels · Corner mounted service valves for easy hook-up and service · Liquid line filter drier shipped loose · Charged for 15 feet of interconnecting tubing · All units ETL and ETLC approved and AHRI certified Split System Air Conditioning FORM NO. A4AC13L-7,8 - 100 (09/2012) WARRANTY · 10 year limited warranty on compressor, 10 year limited warranty on all parts, extended warranty available* *Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. Lifetime limited heat exchanger warranty applies to registered equipment only (Standard 20 years with no online registration). See full warranty at www.alliedair.com for terms, conditions and exclusions. 13 SEER Split System Air Conditioner Model Number Guide 4 AC 13 Refrigerant R410a AC = Condenser 13 - 13 SEER Nominal Family/Coil Protection L = Louvered L 24 P - 7,8 A MMininoorrRReevvisisioionnCCooddee MMaajojorrRReevvisisioionnCCooddee Voltage Voltage PP--220088-2-23300vv/6/600hhzz SingleSiPnhgalesePhase NNoommiinnaall CCaappaacciittyy 2244 -- 2244,,000000 BBttuuhh Electrical and Physical Data Model Voltage/ Hz/ Phase Voltage Range Min. Circuit (Amps) Max. Fuse (Amps) Compressor Rated Locked Load Rotor (Amps) (Amps) Fan Motor Full Load (Amps) Rated HP Nom. RPM Refrig. Charge (oz.) Shipping Weight (lbs.) Louvered 4AC13*18P-7, 8 208-230/60/1 197-253 10.90 15 8.1 39 0.7 1/10 1010 62 136 4AC13*24P-7, 8 208-230/60/1 197-253 14.10 20 10.7 53 0.7 1/10 1010 63 137 4AC13*30P-7, 8 208-230/60/1 197-253 15.60 25 11.6 59 1.1 1/5 1090 82 147 4AC13*36P-7, 8 208-230/60/1 197-253 20.10 35 15.2 70 1.1 1/5 1090 84 149 4AC13*42P-7, 8 208-230/60/1 197-253 28.10 45 21.1 90 1.7 1/4 825 104 194 4AC13*48P-7, 8 208-230/60/1 197-253 31.90 50 24.1 100 1.7 1/4 825 124 192 4AC13*60P-7, 8 208-230/60/1 197-253 29.40 50 22.1 120 1.7 1/4 830 144 205 Overcurrent protection device Factory charge adequate for 15 feet of line set. Adjust per Installation Instructions. * = Louvered Unit Dimensions & Sound Ratings Model Dimensions A - width B - depth C - height (in.) (in.) (in.) Sound Ratings (dBa) 4AC13*18P-7, 8 24.25 24.25 25 74 4AC13*24P-7, 8 24.25 24.25 25 74 4AC13*30P-7, 8 24.25 24.25 29 74 4AC13*36P-7, 8 24.25 24.25 29 74 4AC13*42P-7, 8 28.25 28.25 29 4AC13*48P-7, 8 28.25 28.25 33 4AC13*60P-7, 8 28.25 28.25 29 79 * = Louvered 79 80 Note: Dimensions listed are unit sizes w/o packaging - Page 2 - Split System Air Conditioner 13 SEER Cooling Performance with Evaporator Coils Outdoor Model Indoor Model Evaporator Coil3 Refrigerant Rated Rated Connection SEER EER AHRI Capacity1 Sensible Capacity CFM Outdoor Indoor BTUH BTUH Refrigerant Line Size Indoor Metering Device Piston2 TXV Suction Liquid Suction Liquid Suction Liquid 4AC13*18P7, 8 E(C,H,M,U)1P23(A,B)+TDR 13.00 11.00 17600 E(C,M,U)1P24(A,B)+TDR 13.00 11.00 17600 E(C,H,M,U)1P29A+TDR 13.00 11.00 17600 E(C,H,M,U)1P23(A,B)+TDR 13.00 11.00 22800 4AC13*24P7, 8 E(C,M,U)1P24(A,B)+TDR E(C,H,M,U)1P29A+TDR E(C,M,U)1P30(A,B)+TDR 13.00 11.00 22800 13.00 11.00 22800 13.00 11.00 22800 E(C,H,M,U)1P36(A,B,C)+TDR 13.00 11.00 22800 E(C,H,M,U)1P23(A,B)+TDR 13.00 11.00 28000 4AC13*30P7, 8 E(C,M,U)1P24(A,B)+TDR E(C,H,M,U)1P29A+TDR E(C,M,U)1P30(A,B)+TDR 13.00 11.00 28000 13.00 11.00 28000 13.00 11.00 28000 E(C,H,M,U)1P36(A,B,C)+TDR 13.00 11.00 28000 4AC13*36P7, 8 E(C,H,M,U)1P36(B,C)+TDR 13.00 11.00 34000 E(C,H,M,U)1P43(B,C)+TDR 13.00 11.00 34000 E(C,H,M,U)1P50C+TDR 13.00 11.00 34000 4AC13*42P7, 8 E(C,H,M,U)1P43C+TDR E(C,H,U)1P49C+TDR E(C,H,M,U)1P50C+TDR 13.00 11.00 40000 13.00 11.00 40000 13.00 11.00 40000 4AC13*48P7, 8 E(C,H,U)1P49C+TDR E(C,H,U)1P62C+TDR E(C,H,U)1P62D+TDR 13.00 11.00 47000 13.00 11.00 47000 13.00 11.00 47000 4AC13*60P7, 8 E(C,H,U)1P49C+TDR E(C,H,U)1P62C+TDR E(C,H,U)1P62D+TDR 13.00 11.00 57000 13.00 11.00 57000 13.00 11.00 57000 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 41000 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 41000 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 41000 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 1Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240. 2Required to achieve AHRI rating. 3A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and Air Handler products. * = Louvered - Page 3 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 18 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Refrigerant Connection Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid BCS2M18C****P 13.00 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 BCS3M18C****P 13.00 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 BCE3M18C****P 13.00 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 BCS2M24V****P 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B EFV08BC 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23A A80DF1E045A12 13.50 11.50 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A80DF1E070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23A A80DF2V070A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23A A80UH1E045A12* 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A80UH1E070B12* 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23A A80UH2V070A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A80UH2V090B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A80UH2V090B16 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A95DF1E045B12S 13.50 11.50 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 4AC13L E(C,H,M,U)1P23B 18P-7,8 E(C,H,M,U)1P23B A95DF2V045B12S A95DF2V070B16S 14.00 12.00 14.00 12.00 17600 17600 12800 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A95UH1E045B12S 13.50 11.50 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A95UH1E070B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A95UH2V045B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A95UH2V070B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A97DSMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A97USMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A96DFMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B A96UHMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B LB*80*84/95V14 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B LH*80*84/95V12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B LUF80*57/72V12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P23B LUF80*84/95V14 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P24B EFV08BC 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P24A A80DF1E045A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 4 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 18, 24 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor Indoor BTUH BTUH Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P24B A80DF1E070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24A A80DF2V070A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24A A80UH1E045A12* 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A80UH1E070B12* 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24A A80UH2V070A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A80UH2V090B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A80UH2V090B16 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95DF1E045B12S 13.50 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95DF2V045B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95DF2V070B16S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH1E045B12S 13.50 11.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH1E070B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH2V045B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH2V070B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 4AC13L E(C,H,M,U)1P24B 18P-7,8 E(C,H,M,U)1P24B A97DSMV070B12 A97USMV070B12 14.00 12.00 14.00 12.00 17600 17600 12800 12800 650 5/8 3/8 3/4 3/8 5/8 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A96DFMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A96UHMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B LB*80*84/95V14 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B LH*80*84/95V12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B LUF80*57/72V12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B LUF80*84/95V14 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29B EFV08BC 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29A A80DF1E045A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29B A80DF1E070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29A A80DF2V070A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29A A80UH1E045A12* 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29B A80UH1E070B12* 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29A A80UH2V070A12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P29B A80UH2V090B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 5 - 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 0.053 A4TXV01 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 18, 24 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated Rated ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P29B A80UH2V090B16 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A95DF1E045B12S 13.50 11.50 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A95DF2V045B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A95DF2V070B16S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A95UH1E045B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A95UH1E070B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A95UH2V045B12S 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 4AC13L 18P-7,8 E(C,H,M,U)1P29B E(C,H,M,U)1P29B A95UH2V070B12S 14.00 12.00 A97DSMV070B12 14.00 12.00 17600 17600 12800 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A97USMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A96DFMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B A96UHMV070B12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B LB*80*84/95V14 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B LH*80*84/95V12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B LUF80*57/72V12 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 E(C,H,M,U)1P29B LUF80*84/95V14 14.00 12.00 17600 12800 650 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.053 A4TXV01 BCS2M24C****P 13.00 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 BCS3M24C****P 13.00 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 BCE3M24C****P 13.00 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 BCS2M24V****P 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23B EFV08BC 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23A A80DF1E045A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 4AC13L 24P-7,8 E(C,H,M,U)1P23A E(C,H,M,U)1P23B A80DF2V070A12 A80DF2V090B16 14.00 12.00 14.00 12.00 22800 22800 16800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23A A80UH1E045A12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23B A80UH1E070B12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23A A80UH2V070A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23B A80UH2V090B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23B A80UH2V090B16 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P23B A95DF2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 6 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 24 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P23B A95DF2V070B16S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B A95UH1E070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B A95UH2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B A95UH2V070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B A97DSMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B A97USMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B A96UHMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B LB*80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B LH*80*84/95V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B LUF80*57/72V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P23B LUF80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B EFV08BC 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24A A80DF1E045A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24A A80DF2V070A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 4AC13L 24P-7,8 E(C,H,M,U)1P24B E(C,H,M,U)1P24A A80DF2V090B16 13.50 11.00 A80UH1E045A12* 13.50 11.00 22800 22800 16800 16800 800 5/8 3/8 3/4 3/8 5/8 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A80UH1E070B12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24A A80UH2V070A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A80UH2V090B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A80UH2V090B16 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95DF2V045B12S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95DF2V070B16S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH1E070B12S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A95UH2V070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A97DSMV070B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A97USMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A96DFMV070B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B A96UHMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P24B LB*80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 7 - 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 24 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P24B LH*80*84/95V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P24B LUF80*57/72V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P24B LUF80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B EFV08BC 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29A A80DF1E045A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A80DF1E070B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29A A80DF2V070A12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A80DF2V090B16 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29A A80UH1E045A12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A80UH1E070B12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29A A80UH2V070A12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A80UH2V090B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A80UH2V090B16 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A95DF2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 4AC13L 24P-7,8 E(C,H,M,U)1P29B E(C,H,M,U)1P29B A95DF2V070B16S A95UH1E070B12S 13.50 11.00 14.00 12.00 22800 22800 16800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A95UH2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A95UH2V070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A97DSMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A97USMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A96DFMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B A96UHMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B LB*80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B LH*80*84/95V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B LUF80*57/72V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P29B LUF80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P30B EFV08BC 14.00 12.00 28000 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P30A A80DF1E045A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P30B A80DF1E070B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P30A A80DF2V070A12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 8 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 24 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection SEER EER Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P30B A80DF2V090B16 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30A A80UH1E045A12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A80UH1E070B12* 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30A A80UH2V070A12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A80UH2V090B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A80UH2V090B16 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95DF2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95DF2V070B16S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95DF2V090C20S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95DF2V110C20S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95UH1E070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95UH2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95UH2V070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A95UH2V090C12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 4AC13L 24P-7,8 E(C,H,M,U)1P30B E(C,H,M,U)1P30B A97DSMV070B12 A97USMV070B12 14.00 12.00 14.00 12.00 22800 22800 16800 16800 800 5/8 3/8 3/4 3/8 5/8 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A97USMV090C12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A96DFMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A96UHMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B A96UHMV090C12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B LB*80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B LH*80*84/95V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B LUF80*57/72V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P30B LUF80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P36B EFV08BC 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P36A A80DF1E045A12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P36B A80DF1E070B12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P36A A80DF2V070A12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P36B A80DF2V090B16 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 E(C,H,M,U)1P36A A80UH1E045A12* 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 9 - 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 3/8 or 1/4 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 0.057 A4TXV01 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 24, 30 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P36B A80UH1E070B12* 13.50 11.50 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36A A80UH2V070A12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A80UH2V090B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A80UH2V090B16 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A95DF2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A95DF2V070B16S 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A95DF2V090C20S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A95DF2V110C20S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A95UH1E070B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A95UH2V045B12S 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 4AC13L 24P-7,8 E(C,H,M,U)1P36B A95UH2V070B12S 14.00 12.00 E(C,H,M,U)1P36B A95UH2V090C12S 14.00 12.00 22800 22800 16800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A97DSMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A97USMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A97USMV090C12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A96DFMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A96UHMV070B12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B A96UHMV090C12 14.00 12.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B LB*80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B LH*80*84/95V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B LUF80*57/72V12 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 E(C,H,M,U)1P36B LUF80*84/95V14 13.50 11.00 22800 16800 800 5/8 3/8 3/4 3/8 5/8 3/8 or 1/4 0.057 A4TXV01 BCS2M30C****P 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 BCS3M30C****P 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 BCE3M30C****P 13.00 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 4AC13L BCS2M36V****P 30P-7,8 E(C,H,M,U)1P23B 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 EFV12BC 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P23A A80DF1E045A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P23B A80DF1E070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P23B A80DF1E090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 10 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 30 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Indoor Expansion Line Size Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 30P-7,8 E(C,H,M,U)1P23A E(C,H,M,U)1P23B E(C,H,M,U)1P23A E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P23B E(C,H,M,U)1P24B E(C,H,M,U)1P24A E(C,H,M,U)1P24B E(C,H,M,U)1P24B E(C,H,M,U)1P24A E(C,H,M,U)1P24B A80DF2V070A12 A80DF2V090B16 A80UH1E045A12* A80UH1E070B12* A80UH1E090B16* A80UH2V070A12 A80UH2V090B12 A80UH2V090B16 A95DF1E045B12S A95DF1E070B16S A95DF2V045B12S A95DF2V070B16S A95UH1E045B12S A95UH1E070B12S A95UH2V045B12S A95UH2V070B12S A97DSMV070B12 A97USMV070B12 A96DFMV070B12 A96UHMV070B12 LB*80*84/95V14 LH*80*84/95V12 LUF80*57/72V12 LUF80*84/95V14 EFV12BC A80DF1E045A12 A80DF1E070B12 A80DF1E090B16 A80DF2V070A12 A80DF2V090B16 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.50 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 11 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 30 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P24A A80UH1E045A12* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A80UH1E070B12* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A80UH1E090B16* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24A A80UH2V070A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A80UH2V090B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A80UH2V090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95DF1E045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95DF1E070B16S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95DF2V045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95DF2V070B16S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95UH1E045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95UH1E070B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95UH2V045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A95UH2V070B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 4AC13L 30P-7,8 E(C,H,M,U)1P24B E(C,H,M,U)1P24B A97DSMV070B12 A97USMV070B12 13.50 11.00 13.50 11.00 28000 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A96DFMV070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B A96UHMV070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B LB*80*84/95V14 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B LH*80*84/95V12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P24B LUF80*84/95V14 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B EFV12BC 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29A A80DF1E045A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80DF1E070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80DF1E090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29A A80DF2V070A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80DF2V090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29A A80UH1E045A12* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80UH1E070B12* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80UH1E090B16* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 12 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 30 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Refrigerant Connection Rated Rated SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P29A A80UH2V070A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80UH2V090B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A80UH2V090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95DF1E045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95DF1E070B16S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95DF2V045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95DF2V070B16S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95UH1E045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95UH1E070B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95UH2V045B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A95UH2V070B12S 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A97DSMV070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A97USMV070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B A96DFMV070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 4AC13L 30P-7,8 E(C,H,M,U)1P29B E(C,H,M,U)1P29B A96UHMV070B12 LB*80*84/95V14 13.50 11.00 13.50 11.00 28000 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B LH*80*84/95V12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B LUF80*57/72V12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P29B LUF80*84/95V14 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30B EFV12BC 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30A A80DF1E045A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30B A80DF1E070B12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30B A80DF1E090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30A A80DF2V070A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30B A80DF2V090B16 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30C A80DF2V110C20 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30A A80UH1E045A12* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30B A80UH1E070B12* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30B A80UH1E090B16* 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 E(C,H,M,U)1P30A A80UH2V070A12 13.50 11.00 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 13 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 30 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated Rated ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P30B E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B 4AC13L 30P-7,8 E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B E(C,H,M,U)1P30C E(C,H,M,U)1P30B, C E(C,H,M,U)1P30B, C E(C,H,M,U)1P30B, C E(C,H,M,U)1P30B, C E(C,H,M,U)1P36B E(C,H,M,U)1P36A A80UH2V090B12 A80UH2V090B16 A80UH2V090C20 A95DF1E045B12S A95DF1E070B16S A95DF1E090C16S A95DF2V045B12S A95DF2V070B16S A95DF2V090C20S A95DF2V110C20S A95UH1E045B12S A95UH1E070B12S A95UH1E090C16S A95UH2V045B12S A95UH2V070B12S A95UH2V090C12S A97DSMV070B12 A97DSMV090C16 A97USMV070B12 A97USMV090C12 A96DFMV070B12 A96DFMV090C16 A96UHMV070B12 A96UHMV090C12 LB*80*84/95V14 LH*80*84/95V12 LUF80*57/72V12 LUF80*84/95V14 EFV12BC A80DF1E045A12 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.00 11.00 13.50 11.00 13.50 11.00 13.50 11.00 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 14 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 30 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 30P-7,8 E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36A E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36A E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36A E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36B A80DF1E070B12 A80DF1E090B16 A80DF2V070A12 A80DF2V090B16 A80DF2V110C20 A80UH1E045A12* A80UH1E070B12* A80UH1E090B16* A80UH2V070A12 A80UH2V090B12 A80UH2V090B16 A80UH2V090C20 A95DF1E045B12S A95DF1E070B16S A95DF1E090C16S A95DF2V045B12S A95DF2V070B16S A95DF2V090C20S A95DF2V110C20S A95UH1E045B12S A95UH1E070B12S A95UH1E090C16S A95UH2V045B12S A95UH2V070B12S A95UH2V090C12S A97DSMV070B12 A97DSMV090C16 A97USMV070B12 A97USMV090C12 A96DFMV070B12 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 28000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 15 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 30, 36 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P36C E(C,H,M,U)1P36B 4AC13L 30P-7,8 E(C,H,M,U)1P36C E(C,H,M,U)1P36B, C E(C,H,M,U)1P36B, C E(C,H,M,U)1P36B, C E(C,H,M,U)1P36B, C BCS2M36C****P BCS3M36C****P BCE3M36C****P BCS2M36V****P E(C,H,M,U)1P36B E(C,H,M,U)1P36B E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36B E(C,H,M,U)1P36C 4AC13L 36P-7,8 E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C A96DFMV090C16 A96UHMV070B12 A96UHMV090C12 LB*80*84/95V14 LH*80*84/95V12 LUF80*57/72V12 LUF80*84/95V14 EFV12BC A80DF1E090B16 A80DF1E110C20 A80DF2V110C20 A80UH1E090B16* A80UH1E090C20* A80UH1E110C20* A80UH2V090C20 A80UH2V110C20 A95DF1E090C16S A95DF1E110C20S A95DF2V090C20S A95DF2V110C20S A95UH1E090C16S A95UH1E110C20S A95UH2V090C12S A95UH2V090C16S A95UH2V090C20S A95UH2V110C16S 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.00 11.00 13.00 11.00 13.00 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 28000 28000 28000 28000 28000 28000 28000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 20400 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.063 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 16 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 36 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 36P-7,8 E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P36C E(C,H,M,U)1P43C E(C,H,M,U)1P43B E(C,H,M,U)1P43C E(C,H,M,U)1P43B E(C,H,M,U)1P43C E(C,H,M,U)1P43B E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C A95UH2V110C20S A97DSMV090C16 A97DSMV090C20 A97DSMV110C20 A97USMV090C12 A97USMV090C16 A97USMV090C20 A97USMV110C20 A96DFMV090C16 A96DFMV090C20 A96DFMV110C20 A96UHMV090C12 A96UHMV090C16 A96UHMV090C20 A96UHMV110C20 EFV12BC A80DF1E090B16 A80DF1E110C20 A80DF2V090B16 A80DF2V110C20 A80UH1E090B16* A80UH1E090C20* A80UH1E110C20* A80UH2V090C20 A80UH2V110C20 A95DF1E090C16S A95DF1E110C20S A95DF2V090C20S A95DF2V110C20S A95UH1E090C16S 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 17 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 36 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated Rated ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 36P-7,8 E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C A95UH1E110C20S A95UH2V090C12S A95UH2V090C16S A95UH2V090C20S A95UH2V110C16S A95UH2V110C20S A97DSMV090C16 A97DSMV090C20 A97DSMV110C20 A97USMV090C12 A97USMV090C16 A97USMV090C20 A97USMV110C20 A96DFMV090C16 A96DFMV090C20 A96DFMV110C20 A96UHMV090C12 A96UHMV090C16 A96UHMV090C20 A96UHMV110C20 LB*80*84/95V14 LUF80*84/95V14 LUF80*112/125V20 EFV16CC A80DF1E110C20 A80DF2V110C20 A80UH1E090C20* A80UH1E110C20* A80UH2V090C20 A80UH2V110C20 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.50 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.50 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 13.50 11.00 34000 34000 34000 34000 34000 34000 34200 34200 34200 34200 34200 34200 34200 34200 34200 34200 34200 34200 34200 34200 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 18 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 36 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace Rated Rated Refrigerant Connection Refrigerant Line Size Indoor Expansion Device SEER EER ARI Capacity1 Sensible Capacity CFM Outdoor Indoor BTUH BTUH 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 36P-7,8 E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C A95DF1E090C16S 13.50 11.00 A95DF1E110C20S 13.50 11.00 A95DF2V090C20S 13.50 11.00 A95DF2V110C20S 13.50 11.00 A95UH1E090C16S 13.50 11.00 A95UH1E110C20S 13.50 11.00 A95UH2V090C12S 13.50 11.00 A95UH2V090C16S 13.50 11.00 A95UH2V090C20S 13.50 11.00 A95UH2V110C16S 13.50 11.00 A95UH2V110C20S 13.50 11.00 A97DSMV090C16 13.50 11.00 A97DSMV090C20 13.50 11.00 A97DSMV110C20 13.50 11.00 A97USMV090C12 13.50 11.00 A97USMV090C16 13.50 11.00 A97USMV090C20 13.50 11.00 A97USMV110C20 13.50 11.00 A96DFMV090C16 13.50 11.00 A96DFMV090C20 13.50 11.00 A96DFMV110C20 13.50 11.00 A96UHMV090C12 13.50 11.00 A96UHMV090C16 13.50 11.00 A96UHMV090C20 13.50 11.00 A96UHMV110C20 13.50 11.00 LUF80*112/125V20 13.50 11.00 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 34000 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 25000 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.072 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 19 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 42 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated Rated ARI Capacity1 Sensible Capacity CFM Outdoor BTUH BTUH Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 42P-7,8 BCS2M42C****P BCS3M42C****P BCE3M42C****P BCS2M42V****P E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P43C E(C,H,M,U)1P49C 13.00 11.00 13.00 11.00 13.00 11.00 13.50 11.00 A80DF1E110C20 13.50 11.00 A80DF2V110C20 13.50 11.00 A80UH1E090C20* 13.50 11.00 A80UH1E110C20* 13.50 11.00 A80UH2V090C20 13.50 11.00 A80UH2V110C20 13.50 11.00 A95DF1E110C20S 13.50 11.00 A95UH1E110C20S 13.50 11.00 A95UH2V090C16S 13.50 11.00 A95UH2V090C20S 13.50 11.00 A95UH2V110C16S 13.50 11.00 A95UH2V110C20S 13.50 11.00 A97DSMV090C16 13.50 11.00 A97DSMV090C20 13.50 11.00 A97DSMV110C20 13.50 11.00 A97USMV090C16 13.50 11.00 A97USMV090C20 13.50 11.00 A97USMV110C20 13.50 11.00 A96DFMV090C16 13.50 11.00 A96DFMV090C20 13.50 11.00 A96DFMV110C20 13.50 11.00 A96UHMV090C16 13.50 11.00 A96UHMV090C20 13.50 11.00 A96UHMV110C20 13.50 11.00 LUF80*112/125V20 13.50 11.00 A80DF1E110C20 13.50 11.00 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 20 - Split System Air Conditioner 13 SEER Cooling Performance with Air Handlers and Furnaces 42 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid 4AC13L 42P-7,8 E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P49C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C E(C,H,M,U)1P50C A80DF2V110C20 13.50 11.00 A80UH1E090C20* 13.50 11.00 A80UH1E110C20* 13.50 11.00 A80UH2V090C20 13.50 11.00 A80UH2V110C20 13.50 11.00 A95DF1E110C20S 13.50 11.00 A95UH1E110C20S 13.50 11.00 A95UH2V090C16S 13.50 11.00 A95UH2V090C20S 13.50 11.00 A95UH2V110C16S 13.50 11.00 A95UH2V110C20S 13.50 11.00 A97DSMV090C16 13.50 11.00 A97DSMV110C20 13.50 11.00 A97USMV090C16 13.50 11.00 A97USMV090C20 13.50 11.00 A97USMV110C20 13.50 11.00 A96DFMV090C16 13.50 11.00 A96DFMV110C20 13.50 11.00 A96UHMV090C16 13.50 11.00 A96UHMV090C20 13.50 11.00 A96UHMV110C20 13.50 11.00 LUF80*112/125V20 13.50 11.00 A80DF1E110C20 13.50 11.00 A80DF2V110C20 13.50 11.00 A80UH1E090C20* 13.50 11.00 A80UH1E110C20* 13.50 11.00 A80UH2V090C20 13.50 11.00 A95DF1E110C20S 13.50 11.00 A95UH2V090C16S 13.50 11.00 A95UH2V090C20S 13.50 11.00 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 21 - 13 SEER Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces 42, 48, 60 Indoor Model Outdoor Model Evaporator Coil or Air Handler3 Variable Speed Furnace SEER EER Refrigerant Connection Rated ARI Capacity1 BTUH Rated Sensible Capacity CFM BTUH Outdoor Indoor Refrigerant Line Size Indoor Expansion Device 2 Piston TXV Suction Liquid Suction Liquid Suction Liquid E(C,H,M,U)1P50C A95UH2V110C16S 13.50 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 E(C,H,M,U)1P50C A95UH2V110C20S 13.50 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 E(C,H,M,U)1P50C A97USMV090C16 13.50 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 4AC13L 42P-7,8 E(C,H,M,U)1P50C E(C,H,M,U)1P50C A97USMV090C20 A97USMV110C20 13.50 11.00 13.50 11.00 40000 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 E(C,H,M,U)1P50C A96UHMV090C16 13.50 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 E(C,H,M,U)1P50C A96UHMV090C20 13.50 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 E(C,H,M,U)1P50C A96UHMV110C20 13.50 11.00 40000 29200 1400 3/4 3/8 7/8 3/8 3/4 3/8 0.075 A4TXV01 BCS2M48C****P 13.00 11.00 47000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 4AC13L 48P-7,8 BCS3M48C****P BCE3M48C****P 13.00 11.00 13.00 11.00 47000 47000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 4AC13L 60P-7,8 BCS2M48V****P BCS2M60C****P BCS3M60C****P BCE3M60C****P 13.50 11.00 13.00 11.00 13.00 11.00 13.00 11.00 47000 57000 56000 56000 34300 1600 7/8 3/8 7/8 3/8 7/8 3/8 0.082 A4TXV02 41000 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 40200 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 40200 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 BCS2M60V****P 13.50 11.00 57000 41000 1800 7/8 3/8 7/8 3/8 7/8 3/8 0.090 A4TXV02 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 22 - Split System Air Conditioner 13 SEER Cooling Performance -- Extended Ratings Outdoor Model 4AC13*18P7, 8 4AC13*24P7, 8 4AC13*30P7, 8 4AC13*36P7, 8 4AC13*43P7, 8 4AC13*48P7, 8 4AC13*60P7, 8 Indoor Outdoor Temp - DB°F Model Indoor 65 82 95 105 115 Piston or Field Installed Temp DB/WB °F Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW TXV 85/72 23,500 0.63 1.27 21,200 0.65 1.52 20,700 0.68 1.66 18,500 0.70 1.83 18,000 0.73 2.00 E*1P24 80/67 75/63 21,600 0.68 1.25 20,600 0.70 1.41 19,000 0.73 1.64 18,000 0.78 1.80 16,600 0.81 2.02 20,200 0.74 1.26 18,500 0.76 1.35 17,000 0.80 1.64 15,100 0.83 1.80 14,200 0.88 1.99 75/57 18,200 1.00 1.26 16,300 1.00 1.30 15,700 1.00 1.65 14,300 1.00 1.81 13,400 1.00 1.99 85/72 29,500 0.63 1.61 27,400 0.65 1.99 25,900 0.68 2.12 23,500 0.72 2.34 22,400 0.73 2.58 E*1P24 80/67 75/63 27,200 0.70 1.59 25,300 0.72 1.95 23,600 0.76 2.10 20,500 0.79 2.31 19,600 0.83 2.54 25,500 0.73 1.57 24,100 0.75 1.91 21,200 0.80 2.08 19,600 0.81 2.29 17,600 0.87 2.50 75/57 22,800 1.00 1.56 21,600 1.00 1.89 19,200 1.00 2.06 18,400 1.00 2.28 16,600 1.00 2.50 85/72 35,100 0.62 1.96 33,100 0.65 2.41 31,000 0.67 2.57 28,400 0.69 3.00 26,800 0.72 3.17 E*1P24 80/67 33,000 0.68 1.92 31,500 0.69 2.39 29,500 0.75 2.56 26,500 0.79 2.97 23,800 0.82 3.13 75/63 31,000 0.71 1.90 29,100 0.73 2.31 26,200 0.77 2.51 24,300 0.82 2.95 21,900 0.84 3.09 75/57 29,500 1.00 1.89 26,400 1.00 2.10 24,000 1.00 2.48 22,100 1.00 2.89 19,600 1.00 3.01 85/72 42,100 0.61 2.40 39,890 0.64 2.86 38,200 0.67 3.22 35,650 0.70 3.61 33,100 0.73 3.99 E*1P36 80/67 39,900 0.68 2.38 37,010 0.73 2.85 34,800 0.76 3.21 32,150 0.79 3.58 29,500 0.81 3.95 75/63 37,900 0.71 2.36 34,727 0.75 2.82 32,300 0.78 3.17 29,600 0.82 3.53 26,900 0.86 3.88 75/57 35,800 1.00 2.33 32,570 1.00 2.77 30,100 1.00 3.11 27,150 1.00 3.47 24,200 1.00 3.82 85/72 52,200 0.61 2.97 49,100 0.63 3.56 46,900 0.65 3.91 44,800 0.69 4.62 41,300 0.70 4.79 E*1P43 80/67 48,300 0.68 2.92 44,200 0.73 3.49 42,300 0.75 3.89 40,200 0.77 4.52 36,400 0.79 4.69 75/63 45,100 0.72 2.88 41,600 0.72 3.35 39,200 0.77 3.80 37,100 0.81 4.49 32,400 0.83 4.59 75/57 40,300 1.00 2.83 38,200 1.00 3.34 35,500 1.00 3.74 34,000 1.00 4.45 32,200 1.00 4.50 85/72 61,100 0.63 3.56 57,870 0.65 4.50 55,400 0.66 4.57 52,000 0.69 5.03 48,600 0.71 5.48 E*1P49 80/67 75/63 56,800 0.69 3.49 53,230 0.71 4.06 50,500 0.73 4.50 46,800 0.76 4.95 43,100 0.79 5.39 53,300 0.72 3.44 49,447 0.75 4.01 46,500 0.77 4.44 42,800 0.80 4.92 39,100 0.83 5.39 75/57 47,000 1.00 3.39 43,713 1.00 3.95 41,200 1.00 4.38 38,500 1.00 4.85 35,800 1.00 5.31 85/72 69,800 0.61 4.02 66,457 0.63 4.75 63,900 0.64 5.30 59,950 0.67 5.87 56,000 0.69 6.44 E*1P49 80/67 75/63 65,400 0.68 3.96 61,490 0.70 4.72 58,500 0.71 5.30 54,600 0.74 5.83 50,700 0.77 6.36 61,400 0.71 3.90 56,923 0.73 4.59 53,500 0.75 5.12 49,650 0.78 5.70 45,800 0.81 6.27 75/57 45,400 1.00 3.83 46,760 1.00 4.54 47,800 1.00 5.09 45,600 1.00 5.67 43,400 1.00 6.24 Note: Extended data shown is actual for models listed and typical for all AHRI matches. * = Louvered - Page 23 - 13 SEER Split System Air Conditioner Accessories Description Where Used Crankcase Heater 18, 24, 30, 36 Crankcase Heater 42, 48, 60 Hard Start Kit 18 Hard Start kit 24, 30, 36, 42, 48, 60 Compressor Low Ambient Kit 18, 24, 30, 36, 42, 48, 60 Sound Blanket 18, 24, 30, 36, 42, 48, 60 Short Cycle Protector 18, 24, 30, 36, 42, 48, 60 Freezestat 3/8" tubing Freezestat 5/8" tubing Time Delay Relay 18, 24, 30, 36, 42, 48, 60 Loss of Charge Kit 18, 24, 30, 36, 42, 48, 60 TXV Kit 18 - 36 TXV Kit 42 - 60 Catalog Number 93M04 93M05 10J42 88M91 45F08 69J03 47J27 93G35 50A93 58M81 84M23 A4TXV01 A4TXV02 All specifications and illustrations subject to change without notice and without incurring obligations. (800) 448-5872 www.armstrongair.com Form No. A4AC13L-7,8-100 (09/2012) ©2012 Allied Air Enterprises LLC, a Lennox International Inc. Company - Page 24 - Printed in the U.S.A.Adobe InDesign CS5.5 (7.5.2) Adobe PDF Library 9.9