Tempstar HH 07610-002-66-60B [12-10]

Tim

TEMPSTAR HH, Tempstar Higher Hood Series Upright Door Dish machines, Specification Sheet,

[Jackson / Dalton Dishwasher] 5700-002-21-70 | CPS Ohio Kitchen Parts and Service

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 2 Pages, 628.20KB

Document DEVICE REPORTJAC0211
TempStar® HH

TempStar® HH

Project Item Quantity CSI Section 11400 Approval Date

Models
TempStar® HH
Specifications
Uses 1.36 gallons (5 liters) of 180°F (82°C) water per rack Total automatic (normal) cycle - 62 seconds 53 racks per hour (normal) cycle 2 HP Wash Pump Motor

Standard Features
· Sani-Sure TM feature assures proper rinse water temperature
· Multi-cycle timer (Extra Heavy, Heavy, Medium, Normal)
· Extended 15sec. high-temperature rinse provides superior coverage and rapid drying
· 20-3/4" wide X 27" high (527mm X 686mm) opening accommodates 18" X 26" (457mm X 660mm) sheet pans and 60-quart mixing bowls
· Auto- ll / auto-start
· Safety door switch
· Delime/manual wash switch
· Low watt density electric wash tank heater
· Hi-limit thermostat and low water protection
· Adjustable bullet feet
· Uses standard 20" X 20" (508 mm X 508 mm) racks
· Front dress panel
· Detergent/rinse additive signal connection fuse box
· Built-in 70° F (21° C) rise booster heater is standard; 40° F (4° C) rise booster heater is available but must be speci ed at time of order
· Lower counter-rotating wash arms and upper wash arm provide optimum spray coverage and superior cleaning action
· Self-draining stainless steel pump
· Split-door design accommodates installations with low ceiling heights
· Large scrap tray

Mandatory Specs
Specify: Electric Steam
Specify voltage ______________ Specify booster size __________
Options
Optional 40° F (4° C) rise booster heater is available at no additional cost (must be speci ed)
Drain Quench System Scaltrol Flanged Feet Water Hammer Arrestor 480V Single Phase Security Package False Panel Safety Door Interlock Steam Booster Heater
Accessories
36-Compartment Rack
4-1/8" tall (105 mm) 5-5/8" tall (143 mm) 7" tall (178 mm) Combination Rack Peg Rack Sheet Pan Rack - for 18" X 26" (457mm X 660mm) baking pans

Single point connections for all utilities
Built-in water pressure regulator and gauge
Field convertible from straight through to corner and vice versa
Heavy duty stainless steel construction

SHIPPING ADDRESS 6209 North U.S. Highway 25E Gray, KY 40734

MAILING ADDRESS P.O. Box 1060 Barbourville, KY 40906

Tel: 1-888-800-5672 Fax: 606-523-1799 [email protected]

www.jacksonmsc.com

TempStar® HH

LEGEND A - DRAIN 1 1/2" IPS B - WATER INLET 3/4" IPS C - ELECTRICAL CONNECTION All vertical dimensions are +/- 1/2" due to adjustable bullet feet.
4 [101mm]

2541 [639mm] 3 [79mm]
C

1 [27mm]

25 [637mm] 17 [432mm]

B

8634 [2202mm]

C

B

73 [1856mm]

7341 [1863mm] 27 [687mm]

3 [76mm] A

B 4 [102mm]

1134 [298mm]

A

1541 [387mm]

34 [861mm]

MACHINE DIMENSIONS

MODEL NO.

HEIGHT

WIDTH

DEPTH

DRAIN SHIPPING INFORMATION HEIGHT WEIGHT CLASS CUBE

HEIGHT

WIDTH

DEPTH

TempStar® HH

76-3/4" (1949 mm)

25-1/4" (641 mm)

25-1/4" (641 mm)

11-3/4" 420 lbs (298 mm) (191 kg)

92.5

77.7 cu. ft.

83" (2108 mm)

33" (838 mm)

49" (1245 mm)

DIMENSION REQUIREMENTS Minimum Ceiling Height (recommended) Wall Clearance (minimum) Standard Table Height Inside Clearance

88" (2 meters) 4" (102 mm) 34" (864 mm) 27" (686 mm)

OPERATING CAPACITY Racks per Hour
OPERATING CYCLE (seconds) Normal Medium Heavy Extra Heavy OPERATING TEMPERATURES Wash (minimum) Rinse (minimum)

Normal Medium

53

28

Wash Rinse

45

15

103

15

163

15

283

15

Heavy 19
Dwell 2 2 2
2

Extra Heavy 11
Total Cycle 62 120 180
300

150° F (66° C) 180° F (82° C)

WASH PUMP MOTOR Wash Pump Motor Horsepower Electric Wash Tank Heater
Electric Rinse Tank Heater - 40°F (4°C) Rise
Electric Rinse Tank Heater - 70°F (21°C) Rise

2 HP

Volts

KW

208V

4.1

230V

5.0

460V

5.0

208V

9.0

230V

11.0

460V

11.0

208V

10.5

230V

12.9

460V

12.9

STEAM REQUIREMENTS Steam Flow Pressure (PSIG) Consumption @ 15 PSIG (Ibs/hr) WATER REQUIREMENTS Inlet Temperature 40°F (4°C) Rise 70°F (21°C) Rise Gallons per Hour Gallons per Rack Waterline Size IPS (minimum) Drainline Size IPS (minimum) Flow Pressure (PSI) Tank Capacity Wash Tank Capacity Booster Tank Capacity APPROXIMATE LOAD AMPS
Power Supply 208V/60HZ/1PH 208V/60HZ/3PH 230V/60HZ/1PH 230V/60HZ/3PH 460V/60HZ/3PH
HOW TO SPECIFY: TempStar® HH

40°F (4°C) Rise AMPS 74.2 47.6 80.9 51.4 23.4

15-20 45
140°F (82 °C) 110°F (60 °C) 72.1 gal (273 L) 1.36 gal (5 L)
3/4" 1- 1/2" 15-25 3 gal (11 L) 8 gal (30 L) 3 gal (11 L)
70°F (21°C) Rise AMPS 81.4 51.8 89.0 56.2 25.8

SHIPPING ADDRESS 6209 North U.S. Highway 25E Gray, KY 40734

MAILING ADDRESS P.O. Box 1060 Barbourville, KY 40906

Tel: 1-888-800-5672 Fax: 606-523-1799 [email protected]

www.jacksonmsc.com 07610-002-66-60B (12/10)

