Project No.: ZKT-220823L6014E-2 Page 1 of 22

FCC TEST REPORT FCC ID:2AI3QAI-IP019

Report Number...................................: ZKT-220823L6014E-2

Date of Test..............................................A...u..g....:22, 2022 to Oct. 26, 2022

Date of issue.........................................: Oct. 26, 2022

Total number of pages.......................... 22

Test Result .......................................... : PASS

Testing Laboratory............................ : Shenzhen ZKT Technology Co., Ltd.

Address

............................................... :

1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China

Applicant's name .............................: Shenzhen Aishine Electronics Co., LTD

Address

............................................... :

Room 512, Floor 5th, XinLong Building,Baishilong, Minzhi, Longhua District, Shenzhen, P.R. China

Manufacturer's name ......................: Shenzhen Aishine Electronics Co., LTD

Address

............................................... :

Room 512, Floor 5th, XinLong Building,Baishilong, Minzhi, Longhua District, Shenzhen, P.R. China

Test specification: Standard................................................: FCC CFR Title 47 Part 15 Subpart C Test procedure..................................... : /

Non-standard test method ................: N/A

Test Report Form No........................ : TRF-EL-107_V0
Test Report Form(s) Originator..... : ZKT Testing
Master TRF ........................................ : Dated: 2020-01-06
This device described above has been tested by ZKT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of ZKT, this document may be altered or revised by ZKT, personal only, and shall be noted in the revision of the document.
Product name..................................... : Wi-Fi Home Security Camera

Trademark ...........................................: N/A Model/Type reference......................... : AI-IP019, AI-IP027

Ratings..................................................

:

Input:100-240V Output:DC 12V

50/60Hz 2.5A

0.6A

Testing procedure and testing location:

Project No.: ZKT-220823L6014E-2 Page 2 of 22

Testing Laboratory....................................... : Shenzhen ZKT Technology Co., Ltd.
Address............................................................ : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China

Tested by (name + signature)....................... : Alen He

Reviewer (name + signature)....................... : Joe Liu Approved (name + signature)....................... : Lake Xie

TABLE OF CONTENTS

Project No.: ZKT-220823L6014E-2 Page 3 of 22

1. VERSION .................................................................................................................................. 4
2. TEST SUMMARY ................................................................................................................... 5
2.1 TEST FACILITY ...............................................................................................................................6 2.2 MEASUREMENT UNCERTAINTY ............................................................................................... 6
3. GENERAL INFORMATION .................................................................................................. 7
3.1 GENERAL DESCRIPTION OF EUT ............................................................................................ 7 3.2 Test mode .........................................................................................................................................7 3.3 Block Diagram of EUT Configuration ........................................................................................... 7 3.4 Test Conditions ................................................................................................................................ 7 3.5 Description Of Support Units (WPT Mode) ................................................................................. 7 3.6 EQUIPMENTS LIST FOR ALL TEST ITEMS ............................................................................. 9
4. CONDUCTED EMISSION TEST ........................................................................................10
4.1 CONDUCTED EMISSION MEASUREMENT ........................................................................... 10 4.1.1 POWER LINE CONDUCTED EMISSION Limits .................................................................. 10 4.1.2 TEST PROCEDURE ..................................................................................................................10 4.1.3 DEVIATION FROM TEST STANDARD ..................................................................................10 4.1.4 TEST SETUP ..............................................................................................................................11 4.1.5 EUT OPERATING CONDITIONS ............................................................................................11 4.1.6 Test Result .................................................................................................................................. 12
5. RADIATED EMISSION MEASUREMENT ....................................................................... 14
5.1 Radiated Emission Limits .............................................................................................................14 5.2 Anechoic Chamber Test Setup Diagram ................................................................................... 15 5.3 Test Procedure .............................................................................................................................. 15 5.4 DEVIATION FROM TEST STANDARD .....................................................................................15 5.5 Test Result ......................................................................................................................................16
6. BANDWIDTH TEST ............................................................................................................. 19
7. ANTENNA REQUIREMENT ............................................................................................... 21
8. TEST SETUP PHOTO ......................................................................................................... 22
9. EUT CONSTRUCTIONAL DETAILS ................................................................................ 22

1. VERSION Report No.
ZKT-220823L6014E-2

Version Rev.01

Project No.: ZKT-220823L6014E-2 Page 4 of 22

Description Initial issue of report

Approved Oct. 26, 2022

2. TEST SUMMARY
Test Item Antenna requirement AC Power Line Conducted Emission
Spurious Emission 20dB Bandwidth

Project No.: ZKT-220823L6014E-2 Page 5 of 22

Section in CFR 47 15.203 15.207
15.209(a)(f) 15.215

Result Pass Pass Pass Pass

NOTE: (1)" N/A" denotes test is not applicable in this Test Report

Project No.: ZKT-220823L6014E-2 Page 6 of 22
2.1 TEST FACILITY Shenzhen ZKT Technology Co., Ltd. Add. : 1/F, No. 101, Building B, No. 6, Tangwei Community Industrial Avenue, Fuhai Street, Bao'an District, Shenzhen, China
FCC Test Firm Registration Number: 692225 Designation Number: CN1299 IC Registered No.: 27033

2.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ± Uwhere expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2providing a level of confidence of approximately 95 %

No.

Item

1

3m camber Radiated spurious emission(9KHz-30MHz)

2

3m camber Radiated spurious emission(30MHz-1GHz)

3

3m chamber Radiated spurious emission(1GHz-18GHz)

4

3m chamber Radiated spurious emission(18GHz-40GHz)

5

Conducted Adjacent channel power

6

Conducted output power uncertainty Above 1G

7

Conducted output power uncertainty below 1G

8

humidity uncertainty

9

Temperature uncertainty

Uncertainty U=4.5dB U=4.8dB U=4.9dB U=5.0dB U=1.38dB U=1.576dB U=1.28dB U=5.3% U=0.59

Project No.: ZKT-220823L6014E-2 Page 7 of 22

3. GENERAL INFORMATION

3.1 GENERAL DESCRIPTION OF EUT

Product Name: Model No.: Model Difference: Serial No.: Hardware version: Software version: Operation Frequency: Modulation type: Antenna Type: Power supply:

Wi-Fi Home Security Camera AI-IP019, AI-IP027 Only the model names are different for different market requirement. N/A V1.0 V1.0 110.5kHz ­ 250kHz MSK Coil antenna Input:100-240V 50/60Hz 0.6A Output:DC 12V 2.5A WPT rated power is 5W

3.2 Test mode Test Modes: Mode 1 AC/DC Adapter (12V/2.5A) + EUT Wireless charging(5W) Note: All test modes were pre-tested, but we only recorded the worst case in this report.

3.3 Block Diagram of EUT Configuration Conducted Emission
DC Mains EUT
Radiated Emission DC Line EUT

3.4 Test Conditions Temperature: 2326
Relative Humidity: 5463 % EUT
3.5 Description Of Support Units (WPT Mode) The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.

Item

Equipment

E-1

Wi-Fi Home Security Camera

E-2 SWITCHING ADAPTOR

Mfr/Brand N/A
LISTED

Model/Type No. AI-IP019 GS120025

Series No. N/A N/A

Note EUT EUT

A-1 Wireless charging tester

YBZ

30W

Item Shielded Type Ferrite Core

Length

Project No.: ZKT-220823L6014E-2 Page 8 of 22

N/A

Auxiliary

Note

Note:
(1) (2) (3)

The support equipment was authorized by Declaration of Confirmation. For detachable type I/O cable should be specified the length in cm inLengthcolumn. "YES" is means "shielded" "with core"; "NO" is means "unshielded" "without core".

3.6 EQUIPMENTS LIST FOR ALL TEST ITEMS Radiation Test equipment

Project No.: ZKT-220823L6014E-2 Page 9 of 22

Item

Equipment

1

Spectrum Analyzer (9kHz-26.5GHz)

2

Spectrum Analyzer (1GHz-40GHz)

3

EMI Test Receiver (9kHz-7GHz)

4

Bilog Antenna (30MHz-1500MHz)

5

Horn Antenna (1GHz-18GHz)

Manufacturer KEYSIGHT
R&S R&S Schwarzbeck Agilent

Type No. 9020A FSQ ESCI7
VULB9168 AH-118

Serial No. Last calibration Calibrated until MY55370835 Oct. 18, 2022 Oct. 17, 2023

100363

Oct. 17, 2022 Oct. 16, 2023

101169

Oct. 18, 2022 Oct. 17, 2023

N/A

Oct. 17, 2022 Oct. 16, 2023

071145

Oct. 17, 2022 Oct. 16, 2023

6

Loop Antenna

TESEQ

HLA6121

58357

Oct. 17, 2022 Oct. 16, 2023

7

Amplifier (30-1000MHz)

EM Electronics

EM330 Amplifier

060747

Oct. 18, 2022 Oct. 17, 2023

8

Amplifier (1GHz-26.5GHz)

Agilent

8449B

3008A00315 Oct. 18, 2022 Oct. 17, 2023

9

RF cables1 (9kHz-30MHz)

N/A

9kHz-30MHz

N/A

Oct. 18, 2022 Oct. 17, 2023

10

RF cables2 (30MHz-1GHz)

N/A

30MHz-1GHz

N/A

Oct. 18, 2022 Oct. 17, 2023

11

RF cables3 (1GHz-40GHz)

N/A

1GHz-40GHz

N/A

Oct. 18, 2022 Oct. 17, 2023

12

ESG Signal Generator

Agilent

E4421B

N/A

Oct. 22, 2022 Oct. 21, 2023

13 Signal Generator

Agilent

N5182A

N/A

Oct. 22, 2022 Oct. 21, 2023

14

Magnetic Field Probe Tester

15

MWRF Power Meter Test system

Narda MW

ELT-400 MW100-RPCB

0-0344 N/A

Oct. 17, 2022 Oct. 16, 2023 Oct. 22, 2022 Oct. 21, 2023

16 D.C. Power Supply

LongWei

TPR-6405D

N/A

\

\

17 EMC Software

Frad

EZ-EMC

Ver.EMC-CON 3A1.1

\

\

18

RF Software

MW

MTS8310

V2.0.0.0

\

\

19

Turntable

MF

MF-7802BS

N/A

\

\

20 Antenna tower

MF

MF-7802BS

N/A

\

\

21 Signal Generator

Agilent

Conduction Test equipment Item Kind of Equipment Manufacturer

1

LISN

R&S

N5182A Type No. ENV216

N/A Serial No.
101471

Oct. 22, 2022 Oct. 21, 2023

Last calibration

Calibrated until

Oct. 22, 2022 Oct. 21, 2023

2

LISN

CYBERTEK

EM5040A E1850400149 Oct. 22, 2022 Oct. 21, 2023

3

Test Cable

N/A

C01

N/A

Oct. 18, 2022 Oct. 17, 2023

4

Test Cable

N/A

C02

N/A

Oct. 18, 2022 Oct. 17, 2023

5 EMI Test Receiver

R&S

ESCI3

101393

Oct. 17, 2022 Oct. 16, 2023

6 Absorbing Clamp 7 EMC Software

DZ Frad

ZN23201 EZ-EMC

15034
Ver.EMC-CON 3A1.1

Oct. 17, 2022 \

Oct. 16, 2023 \

4. CONDUCTED EMISSION TEST 4.1 CONDUCTED EMISSION MEASUREMENT

Project No.: ZKT-220823L6014E-2 Page 10 of 22

Test Requirement: Test Method: Test Frequency Range: Receiver setup:

FCC Part15 C Section 15.207 ANSI C63.10:2013 150KHz to 30MHz RBW=9KHz, VBW=30KHz, Sweep time=auto

4.1.1 POWER LINE CONDUCTED EMISSION Limits

FREQUENCY (MHz)
0.15 -0.5 0.50 -5.0 5.0 -30.0

Limit (dBuV)

Quas-peak

Average

66 - 56 *

56 - 46 *

56.00

46.00

60.00

50.00

Standard
FCC FCC FCC

Note: (1) *Decreases with the logarithm of the frequency.

4.1.2 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item ­EUT Test Photos.
4.1.3 DEVIATION FROM TEST STANDARD
No deviation

4.1.4 TEST SETUP

Ve rtic a l R e fe re n c e G ro u n d P la n e

40cm

EUT

Project No.: ZKT-220823L6014E-2 Page 11 of 22
Te s t R e c e iv e r

L IS N

80cm

H o riz o n ta l R e fe re n c e G ro u n d P la n e

N o te : 1 .S u p p o rt u n its w e re c o n n e c te d to s e c o n d L IS N .

2 .B o th o f L IS N s (A M N ) a re 8 0 c m fro m E U T a n d a t le a s t 8 0

cm

fro m o th e r u n its a n d o th e r m e ta l p la n e s

s u p p o rt. u n its .

4.1.5 EUT OPERATING CONDITIONS
The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data.

4.1.6 Test Result

Temperature Pressure Test Voltage 

26 101kPa AC 120V/60Hz

Project No.: ZKT-220823L6014E-2 Page 12 of 22

Relative Humidity Phase :

54% L

Notes: 1.An initial pre-scan was performed on the line and neutral lines with peak detector. 2.Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3.Mesurement Level = Reading level + Correct Factor

Temperature Pressure Test Voltage 

26 101kPa AC 120V/60Hz

Project No.: ZKT-220823L6014E-2 Page 13 of 22

Relative Humidity Phase :

54% N

Notes: 1.An initial pre-scan was performed on the line and neutral lines with peak detector. 2.Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3.Mesurement Level = Reading level + Correct Factor

Project No.: ZKT-220823L6014E-2 Page 14 of 22

5. RADIATED EMISSION MEASUREMENT

Test Requirement: Test Method: Test Frequency Range: Test site: Receiver setup:

FCC Part15 C Section 15.209 ANSI C63.10:2013

9kHz to 1GHz

Measurement Distance: 3m

Frequency

Detector

RBW VBW

Value

9KHz-90KHz

peak

9KHz 30KHz

peak

9KHz-90KHz

Average

9KHz 30KHz Average

90KHz-110KHz Quasi-peak 9KHz 30KHz Quasi-peak

110KHz-490KHz

peak

9KHz 30KHz

peak

110KHz-490KHz Average

9KHz 30KHz Average

490KHz-30MHz Quasi-peak 9KHz 30KHz Quasi-peak

30MHz-1GHz Quasi-peak 100KHz 300KHz Quasi-peak

Above 1GHz

Peak Peak

1MHz 1MHz

3MHz 10Hz

Peak Average

5.1 Radiated Emission Limits

Limits for frequency below 30MHz

Frequency

Limit (uV/m)

0.009-0.490 0.490-1.705
1.705-30

2400/F(kHz) 24000/F(kHz)
30

Measurement Distance(m)
300 30 30

Limits for frequency Above 30MHz Frequency
30MHz-88MHz 88MHz-216MHz 216MHz-960MHz 960MHz-1GHz
Above 1GHz

Limit (dBuV/m @3m) 40.00 43.50 46.00 54.00 54.00 74.00

Remark
Remark Quasi-peak Value Quasi-peak Value Quasi-peak Value Quasi-peak Value
Average Value Peak Value

5.2 Anechoic Chamber Test Setup Diagram ARadiated Emission Test-Up Frequency Below 30MHz

Project No.: ZKT-220823L6014E-2 Page 15 of 22

BRadiated Emission Test-Up Frequency 30MHz~1GHz
The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the ANSI C63.10-2013. The specification used was the FCC 15.209 and FCC 15.205 limits. 5.3 Test Procedure
The EUT is placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can move up and down between 1 to 4 meters to find out the maximum emission level. Broadband antenna (calibrated by dipole antenna) are used as a receiving antenna. Both horizontal and vertical polarization of the antenna are set on measurement. 5.4 DEVIATION FROM TEST STANDARD No deviation

5.5 Test Result
Measurement data:
Note: Limit dBuV/m @3m = Limit dBuV/m @300m+ 80 Limit dBuV/m @3m = Limit dBuV/m @30m + 40
9 kHz~30 MHz

Project No.: ZKT-220823L6014E-2 Page 16 of 22

Frequency (kHz) 24.83 56.72 112.17
125.00* 133.77 685.35 965.71 1228.35

Meter Reading (dBV) 31.63 43.29 38.64 57.13 37.12 32.45 36.84 29.52

Factor (dB) 20.14 20.33 20.55 20.55 20.55 20.64 21.26 22.32

Emission Level (dBV/m) 51.78 63.62 59.19 77.68 57.67 53.09 58.10 51.84

Limits (dBV/m)
119.70 112.53 106.61 105.67 85.08 70.89 67.91 65.82

Note: Pre-scan in the all of mode, the worst case in of was recorded. Factor = antenna factor + cable loss ­ pre-amplifier. Margin = Emission Level- Limit. " * ": Fundamental frequency.

Margin (dB) -67.92 -48.91 -47.42 -27.99 -27.41 -17.80 -9.81 -13.98

Detector Type
AV AV AV AV AV QP QP QP

30MHz-1GHz
Temperature: Pressure: Test Voltage:

26 101 kPa AC 120V/60Hz

Project No.: ZKT-220823L6014E-2 Page 17 of 22

Relative Humidity: Polarization:

54% Horizontal

Temperature: Pressure: Test Voltage:

26 101kPa AC 120V/60Hz

Project No.: ZKT-220823L6014E-2 Page 18 of 22

Relative Humidity: Polarization:

54% Vertical

Remarks: 1.Final Level =Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor 2.The emission levels of other frequencies are very lower than the limit and not show in test report.

Project No.: ZKT-220823L6014E-2 Page 19 of 22
6. BANDWIDTH TEST
1. Set RBW = 10Hz. 2. Set the video bandwidth (VBW)  3 x RBW. 3. Detector = Peak. 4. Trace mode = max hold. 5. Sweep = auto couple. 6. Allow the trace to stabilize. 7. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 20 dB relative to the maximum level measured in the fundamental emission.
TEST SETUP

Temperature Pressure

26  101kPa

Project No.: ZKT-220823L6014E-2 Page 20 of 22

Relative Humidity

54%

Frequency (KHz)
221.5

20dB bandwidth 99% bandwidth

(Hz)

(Hz)

229

211

Result Pass

Project No.: ZKT-220823L6014E-2 Page 21 of 22

7. ANTENNA REQUIREMENT

Standard requirement:

FCC Part15 C Section 15.203 /247(c)

15.203 requirement:

An intentional radiator shall be designed to ensure that no antenna other than that furnished by the

responsible party shall be used with the device. The use of a permanently attached antenna or of an

antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a

broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is

prohibited.

15.247(c) (1)(i) requirement:

(i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point operations

may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted

output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the

antenna exceeds 6dBi.

8. TEST SETUP PHOTO

Project No.: ZKT-220823L6014E-2 Page 22 of 22

Reference to the appendix I for details.

9. EUT CONSTRUCTIONAL DETAILS