Measurement Report

Kent

Test Report

U-tec Group Inc. ULTICAM-D01 Ulticam Dot 2AJZ2-ULTICAM-D01 2AJZ2ULTICAMD01 ulticam d01

download (pdf)

ULTICAM-D01 Ulticam Dot by U tec Group

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 41 Pages, 5.09MB

Document DEVICE REPORTULTICAM-D01-Test-Report-U-tec-Group-2ajz2-ulticam-d01-ex-1-4
FCC Test Report
Report No: FCS202403068W02 Issued for

Applicant: Address: Product Name:

U-tec Group Inc.
32920 Alvarado-Niles Rd Ste 220, Union City, CA 945 87
Ulticam Dot

Brand Name:

N/A

Model Name:

ULTICAM-D01

Series Model:

N/A

FCC ID:

2AJZ2-ULTICAM-D01

Issued By: Flux Compliance Service Laboratory
Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan
Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 2 of 44

Report No.: FCS202403068W02

TEST RESULT CERTIFICATION

Applicant's Name...................... : U-tec Group Inc.

Address...................................... : 32920 Alvarado-Niles Rd Ste 220, Union City, CA 94587

Manufacture's Name................ : U-tec Group Inc.

Address...................................... : 32920 Alvarado-Niles Rd Ste 220, Union City, CA 94587

Product Description Product Name........................... : Brand Name...............................: Model Name.............................. :

Ulticam Dot N/A ULTICAM-D01

Series Model..............................: N/A

Test Standards.......................... : FCC Part15.247

Test Procedure.......................... : ANSI C63.10-2013
This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document.
Date of Test.................................. :

Date (s) of performance of tests. : Mar 20, 2024~ Mar 25, 2024

Date of Issue.................................: Mar 25, 2024

Test Result.....................................: Pass

Tested by

:

Reviewed by

:

Approved by

:

(Scott Shen) (Duke Qian) (Jack Wang)

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 3 of 44

Report No.: FCS202403068W02

Table of Contents

Page

1. SUMMARY OF TEST RESULTS .............................................................................................. 6 1.1 TEST FACTORY ................................................................................................................ 7 1.2 MEASUREMENT UNCERTAINTY .....................................................................................7
2. GENERAL INFORMATION .......................................................................................................8 2.1 GENERAL DESCRIPTION OF THE EUT ..........................................................................8 2.2 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED ............. 10 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS .................11 2.4 EQUIPMENTS LIST .........................................................................................................12
3. 6DB BANDWIDTH .................................................................................................................. 13 3.1 Limit .................................................................................................................................. 13 3.2 Test Procedure ................................................................................................................. 13 3.3 Test setup ......................................................................................................................... 13 3.4 Test results ....................................................................................................................... 13
4 CONDUCTED OUTPUT POWER ............................................................................................ 18 4.1 limit ................................................................................................................................... 18 4.2 test procedure .................................................................................................................. 18 4.3 TEST SETUP ................................................................................................................... 18 4.4 test results ........................................................................................................................ 18
5. POWER SPECTRAL DENSITY ..............................................................................................19 5.1 LIMIT ................................................................................................................................ 19 5.2 TEST PROCEDURE ........................................................................................................ 19 5.3 TEST SETUP ................................................................................................................... 19 5.4 TEST RESULTS ...............................................................................................................20 5.5 original test data ...............................................................................................................20
6. Band edge and spurious(conducted) ................................................................................. 23 6.1 LIMIT ................................................................................................................................ 23 6.2 TEST PROCEDURE ........................................................................................................ 23 6.3 TEST SETUP ................................................................................................................... 23 6.4 TEST RESULTS ...............................................................................................................24 6.5 Original test data .............................................................................................................. 24
7 RADIATED EMISSION MEASUREMENT ............................................................................... 28 7.1 RADIATED EMISSION LIMITS ........................................................................................28

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 4 of 44

Report No.: FCS202403068W02

Table of Contents

Page

7.2 TEST PROCEDURE ........................................................................................................ 29 7.3 TESTSETUP .................................................................................................................... 30 7.4. TEST RESULTS ..............................................................................................................32
8. ANTENNA REQUIREMENT ................................................................................................... 41 8.1 STANDARD REQUIREMENT ..........................................................................................41 8.2 RESULT ............................................................................................................................41

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 5 of 44

Report No.: FCS202403068W02

Revision History

Rev.

Issue Date

Effect Page

Contents

00

Mar 25, 2024

All

Initial Issue

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 6 of 44

Report No.: FCS202403068W02

1. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02

FCC Part 15.247,Subpart C

Standard Section
FCC 15.247 (a) (2)

Test Item 6dB Bandwidth

Judgment PASS

FCC 15.247 (b) (3)

Conducted Output Power

PASS

FCC 15.247 (e)
FCC 15.247 (d)
FCC 15.247 (d) FCC 15.209 FCC 15.205
FCC 15.247 (d) FCC 15.209 FCC 15.205 FCC 15.207

Power Spectral Density Band-edge and Spurious Emissions
(Conducted) Radiated Spurious Emissions
Radiated Band Edge Compliance
Power Line Conducted Emission

FCC 15.203

Antenna requirement

PASS PASS PASS
PASS N/A PASS

15.205

Restricted Band Edge Emission

NOTE: (1)" N/A" denotes test is not applicable in this Test Report (2) All tests are according to ANSI C63.10-2013

PASS

Remark -----
--
--
----

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 7 of 44

Report No.: FCS202403068W02

1.1 TEST FACTORY

Company Name: Address:

Flux Compliance Service Laboratory
Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan

Telephone:

+86-769-27280901

Fax:

+86-769-27280901

Laboray Accreditations

FCC Test Firm Registration Number:

514908

CNAS Number:

L15566

Designation number:

CN0127

A2LA accreditation number:

5545.01

ISED Number:

25801

CAB ID

CN0097

1.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %.

No.

Item

Uncertainty

1

RF output power, conducted

±0.68dB

2

Unwanted Emissions, conducted

±2.988 dB

3

Conducted Emission (9KHz-150KHz)

±4.13 dB

4

Conducted Emission (150KHz-30MHz)

±4.74 dB

5

All emissions radiated (9KHz -30MHz)

±3.1 dB

6

All emissions,radiated(<1G) 30MHz-1000MHz

±5.2 dB

7

All emissions,radiated 1GHz -18GHz

±4.66 dB

8

All emissions,radiated 18GHz -40GHz

±4.31 dB

9

PSD

±1.24 dB

10

Occupied bandwidth

±0.3 dB

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 8 of 44

Report No.: FCS202403068W02

2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT

Product Name

Ulticam Dot

Trade Name

N/A

Model Name

ULTICAM-D01

Series Model

N/A

Model Difference

N/A

Channel List

Please refer to the Note 2.

Operation frequency Modulation: Transmitter rate: Power supply

IEEE 802.11b: 2412MHz-2462MHz IEEE 802.11g: 2412MHz-2462MHz IEEE 802.11n HT20: 2412MHz-2462MHz IEEE 802.11b: DSSS (CCK, QPSK, BPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n HT20,: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11b: 1, 2, 5.5, 11 Mbps IEEE 802.11g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps IEEE 802.11n HT20: up to 20MHz max 65Mbps
DC 6V

Battery

DC 1.5V*4AA

Number of samples

FCS202403068W02

Hardware version number V1.0

Software version number V1.0

Connecting I/O Port(s)

Please refer to the User's Manual

Note: 1. For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual.

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 9 of 44

Report No.: FCS202403068W02

2.

Channel List

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

01

2412

05

2432

09

2452

02

2417

06

2437

10

2457

03

2422

07

2442

11

2462

04

2427

08

2447

3. Table for Filed Antenna

Ant.

Brand

Model Name

Antenna Type Connector Gain (dBi)

NOTE

1

N/A

UL2109-19

FPC Antenna

N/A

2.49

Antenna

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 10 of 44

Report No.: FCS202403068W02

1
2.2 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED During testing channel & power controlling software provided by the customer was used to control the operating channel as well as the output power level. The RF output power selection is for the setting of RF output power expected by the customer and is going to be fixed on the firmware of the final end product.

Block diagram of EUT configuration for test Mode 1:

EUT

Test software: AmebaZ2_mptool_1v3.exe
The test softeware was used to control EUT work in continuous TX mode, and select test channel, Wireless mode as below table

Note: (1) According exploratory test, EUT will have maximum output power in those data rate, so those data rate were used for all test, (2) During the test, the dutycycle>98%, the test voltage was tuned from 85% to 115% of the Nominal rate supply votage, and found that the worst case was the nominal rated supply condition, So the report just shows that condition's data
Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 11 of 44

Report No.: FCS202403068W02

2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.
Necessary accessories

Item Equipment

Mfr/Brand

Model/Type No.

Serial No.

Note

Item Equipment

1

N/A

Support units

Mfr/Brand

Model/Type No.

N/A

N/A

Serial No.
N/A

Note N/A

Note:
(1) The support equipment was authorized by Declaration of Confirmation. (2) For detachable type I/O cable should be specified the length in cm inLengthcolumn. (3) "YES" is means "shielded" "with core"; "NO" is means "unshielded" "without core".

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 12 of 44

Report No.: FCS202403068W02

2.4 EQUIPMENTS LIST

Radiation Test equipment
Kind of Equipment Manufacturer

Type No.

Company No. Last calibration Calibrated until

EMI Test Receiver

R&S

ESCI

FCS-E014 2023. 08.29 2024. 08.28

Signal Analyzer

R&S

FSV40-N

FCS-E012 2023. 08.29 2024. 08.28

Active loop Antenna

ZHINAN

ZN30900C

FCS-E013 2023. 08.29 2024. 08.28

Bilog Antenna

SCHWARZBECK VULB 9168

FCS-E002 2023. 08.29 2024. 08.28

Horn Antenna

SCHWARZBECK BBHA 9120D

SHF-EHF Horn Antenna (18G-40GHz)
Pre-Amplifier(0.1M-3G Hz)
Pre-Amplifier (1G-18GHz)
Pre-Amplifier (18G-40GHz)
Temperature & Humidity

A-INFO EMCI N/A TERA-MW HTC-1

LB-180400-KF EM330N
TSAMP-0518SE TRLA-0400 victor

FCS-E003 FCS-E018 FCS-E004 FCS-E014 FCS-E019 FCS-E005

2023. 08.29 2023. 08.29 2023. 08.29 2023. 08.29 2023. 08.29 2023. 08.29

2024. 08.28 2024. 08.28 2024. 08.28 2024. 08.28 2024. 08.28 2024. 08.28

Conduction Test equipment
Kind of Equipment Manufacturer

Type No. Company No. Last calibration Calibrated until

EMI Test Receiver

R&S

ESRP

FCS-E014

2023. 08.29

2024. 08.28

LISN

R&S

ENV216

FCS-E007

2023. 08.29

2024. 08.28

LISN Temperature &
Humidity

ETS HTC-1

3810/2NM victor

FCS-E009 FCS-E008

2023. 08.29 2023. 08.29

2024. 08.28 2024. 08.28

RF Connected Test
Kind of Equipment
MXA SIGNAL Analyzer
MXG Vector Signal

Manufacturer Keysight Agilent

Spectrum Analyzer

R&S

Power Sensor
Wireless Communications Test
Set

Agilent R&S

Type No. N9020A N5182A FSV-40 RPR3006W
CMW 500

Company No. Last calibration Calibrated until

FCS-W005

2023. 08.29

2024. 08.28

FCS-W004

2023. 08.29

2024. 08.28

FCS-E025

2023. 08.29

2024. 08.28

FCS-W002

2023. 08.29

2024. 08.28

FCS-W006

2023. 08.29

2024. 08.28

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 13 of 44

Report No.: FCS202403068W02

3. 6DB BANDWIDTH
3.1 Limit For direct sequence systems, the minimum 6dB bandwidth shall be at least 500 kHz

3.2 Test Procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Set the spectrum analyzer as follows

RBW:

100kHz

VBW:

300kHz

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Allow the trace to stabilize, measure the maximum width of the emission that is constrained by the

frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are

attenuated by 6 dB relative to the maximum level measured in the fundamental emission

3.3 Test setup

3.4 Test results
Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 14 of 44

Report No.: FCS202403068W02

TestMode
802.11b 802.11b 802.11b 802.11g 802.11g 802.11g 802.11n 20 802.11n 20 802.11n 20

Channel (MHz)
2412MHz 2437MHz 2462MHz 2412MHz 2437MHz 2462MHz 2412MHz 2437MHz 2462MHz

6dB Bandwidth (MHz)
9.420 8.760 9.840 16.440 16.350 16.410 17.640 17.340 17.640

99%OBW (MHz)
14.010 13.857 14.111 16.758 16.634 16.765 17.863 17.763 17.898

Limit [MHz] Verdict

0.5

Pass

0.5

Pass

0.5

Pass

0.5

Pass

0.5

Pass

0.5

Pass

0.5

Pass

0.5

Pass

0.5

Pass

3.5 Original Test Data 6BW,11b,Lowest

OCB,11b,Lowest

6BW,11b,Middle

OCB,11b,Middle

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 15 of 44

Report No.: FCS202403068W02

6BW,11b,Highest

OCB,11b,Highest

6BW,11g,Lowest

OCB,11g,Lowest

6BW,11g,Middle
Flux Compliance Service Laboratory

OCB,11g,Middle

Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan

Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 16 of 44

Report No.: FCS202403068W02

6BW,11g,Highest

OCB,11g,Highest

6BW,11n(HT20),Lowest

OCB,11n(HT20),Lowest

6BW,11n(HT20),Middle

OCB,11n(HT20),Middle

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 17 of 44

Report No.: FCS202403068W02

6BW,11n(HT20),Highest

OCB,11n(HT20),Highest

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 18 of 44

Report No.: FCS202403068W02

4 CONDUCTED OUTPUT POWER
4.1 limit For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt. If transmitting antennas of directional gain greater than 6 dBi are used, the conducted output power from the intentional radiator shall be reduced below the stated values as appropriate, by the amount in dB that the directional gain of the antenna exceeds 6 dBi.
4.2 test procedure a. Connect each EUT's antenna output to Power Sensor by RF cable and attenuator b. The EUT was set to continuously transmitting in the max power during the test.
4.3 TEST SETUP

4.4 test results

TestMode
802.11b 802.11b 802.11b 802.11g 802.11g 802.11g 802.11n 20 802.11n 20 802.11n 20

Channel (MHz) ResultdBm

2412MHz 2437MHz 2462MHz 2412MHz 2437MHz 2462MHz 2412MHz 2437MHz 2462MHz

14.31 14.00 14.65 14.89 13.44 13.27 12.97 12.41 12.36

LimitdBm Verdict

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 19 of 44

Report No.: FCS202403068W02

5. POWER SPECTRAL DENSITY
5.1 LIMIT For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous transmission.

5.2 TEST PROCEDURE

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Set the spectrum analyzer as follows:

Center frequency

DTS Channel center frequency

RBW:

3 kHz  RBW  100 kHz

VBW:

 3RBW

Span

1.5 times the DTS bandwidth

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Allow the trace to stabilize, use the peak marker function to determine the maximum amplitude level within the RBW
(4) If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.
5.3 TEST SETUP

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 20 of 44

Report No.: FCS202403068W02

5.4 TEST RESULTS

TestMode

Channel (MHz)

802.11b 802.11b 802.11b 802.11g 802.11g 802.11g 802.11n 20 802.11n 20 802.11n 20

2412MHz 2437MHz 2462MHz 2412MHz 2437MHz 2462MHz 2412MHz 2437MHz 2462MHz

5.5 original test data

Result dBm/3KHz
-12.79 -11.16 -12.89 -15.30 -14.31 -14.78 -15.26 -14.02 -14.76

Limit dBm/3KHz
8 8 8 8 8 8 8 8 8

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass

802.11b-2412MHz

802.11b-2437MHz

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

802.11b-2462MHz

Page 21 of 44

Report No.: FCS202403068W02

802.11g-2412MHz

802.11g-2437MHz

802.11g-2462MHz

802.11n 20-2412MHz

802.11n 20-2437MHz

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

802.11n 20-2462MHz

Page 22 of 44

Report No.: FCS202403068W02

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 23 of 44

Report No.: FCS202403068W02

6. Band edge and spurious(conducted)
6.1 LIMIT In any 100kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 30dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power.

6.2 TEST PROCEDURE

(1) Connect EUT's antenna output to spectrum analyzer by RF cable.

(2) Establish a reference level by using the following procedure:

Center frequency

DTS Channel center

frequency

RBW:

100kHz

VBW:

300kHz

Span

1.5times the DTS bandwidth

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(3) Establish Allow the trace to stabilize, use the peak marker function to determine the maximum peak

power level to establish the reference level.

(4) Set the spectrum analyzer as follows:

RBW:

100kHz

VBW:

300kHz

Span

Encompass frequency range to be

measured

Number of measurement points

span/RBW

Detector Mode:

Peak

Sweep time:

auto

Trace mode

Max hold

(5) Allow the trace to stabilize, use the peak marker function to determine the maximum amplitude of

all unwanted emissions outside of the authorized frequency band

6.3 TEST SETUP

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 24 of 44

Report No.: FCS202403068W02

6.4 TEST RESULTS Eut set mode 802.11b 802.11g 802.11n 20

CH or Frequency
CH1 CH11 CH1 CH11 CH1 CH11

6.5 Original test data

Result
Pass Pass Pass Pass Pass Pass

802.11b Low CH

802.11b High CH

802.11g low CH

802.11g high CH

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

802.11n20 Low CH

Page 25 of 44

Report No.: FCS202403068W02

802.11n20 High CH

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 26 of 44

Report No.: FCS202403068W02

6.6 Spurious emissions 30MHz-25GHz

(802.11b) Lowest channel

802.11b Middle CH, 2437MHz

802.11b High CH, 2462MHz

802.11g Low CH, 2412MHz

802.11g Middle CH, 2437MHz

802.11g High CH, 2462MHz

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 27 of 44

Report No.: FCS202403068W02

802.11n 20 Low CH, 2412MHz

802.11n 20 Middle CH, 2437MHz

802.11n 20 High CH, 2462MHz

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 28 of 44

Report No.: FCS202403068W02

7 RADIATED EMISSION MEASUREMENT

7.1 RADIATED EMISSION LIMITS

In any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the Restricted band specified on Part15.205(a)&209(a) limit in the table and according to ANSI C63.10-2013 below has to be followed LIMITS OF RADIATED EMISSION MEASUREMENT (0.009MHz - 1000MHz)

Frequencies

Field Strength

Measurement Distance

(MHz)

(micorvolts/meter)

(meters)

0.009~0.490

2400/F(KHz)

300

0.490~1.705

24000/F(KHz)

30

1.705~30.0

30

30

30~88

100

3

88~216

150

3

216~960

200

3

Above 960

500

3

LIMITS OF RADIATED EMISSION MEASUREMENT (1GHz-25 GHz)

FREQUENCY (MHz) Above 1000

PEAK 74

(dBuV/m) (at 3M) AVERAGE 54

Notes: (1) The limit for radiated test was performed according to FCC PART 15C. (2) The tighter limit applies at the band edges. (3) Emission level (dBuV/m)=20log Emission level (uV/m).

For Radiated Emission Spectrum Parameter Attenuation Detector Start Frequency Stop Frequency
RB / VB (emission in restricted band)

Setting Auto
Peak/AV 1000 MHz(Peak/AV) 10th carrier hamonic(Peak/AV)
PK=1MHz / 1MHz, AV=1 MHz /10 Hz

For Band edge Spectrum Parameter Detector
Start/Stop Frequency
RB / VB (emission in restricted band)

Setting Peak/AV Lower Band Edge: 2300 to 2403 MHz Upper Band Edge: 2479 to 2500 MHz PK=1MHz / 1MHz, AV=1 MHz / 10 Hz

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 29 of 44

Report No.: FCS202403068W02

Receiver Parameter Attenuation
Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency

Setting Auto
9kHz~90kHz / RB 200Hz for PK & AV 90kHz~110kHz / RB 200Hz for QP
110kHz~490kHz / RB 200Hz for PK & AV 490kHz~30MHz / RB 9kHz for QP
30MHz~1000MHz / RB 120kHz for QP

7.2 TEST PROCEDURE
a. The measuring distance of at 3 m shall be used for measurements at frequency 0.009MHz up to 1GHz,and above 1GHz.
b. The EUT was placed on the top of a rotating table 0.1 meters (above 1GHz is 1.5 m) above the ground at a 3 meter anechoic chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
c. The height of the equipment shall be 0.1 m(above 1GHz is 1.5 m); the height of the test antenna shall vary between 1 m to 4 m. horizontal and vertical polarizations of the antenna are set to make the measurement.
d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then QuasiPeak detector mode re-measured.
e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed.
f. For the actual test configuration, please refer to the related Item ­EUT Test Photos.
Note:
Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 30 of 44
7.3 TESTSETUP ARadiated Emission Test-Up Frequency Below 30MHz

Report No.: FCS202403068W02

BRadiated Emission Test-Up Frequency 30MHz~1GHz

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 31 of 44
CRadiated Emission Test-Up Frequency Above 1GHz

Report No.: FCS202403068W02

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 32 of 44

Report No.: FCS202403068W02

7.4. TEST RESULTS

(9KHz-30MHz)

Temperature:

22.7

Test Voltage:

DC 6V

Freq. (MHz)
---

Reading (dBuV/m)
---

Relative Humidity: Test Mode:

61% 802.11b

Limit (dBuV/m)
---

Margin (dB) ---

State P/F ---

Test Result
PASS PASS

Note: The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB); Limit line = specific limits (dBuv) + distance extrapolation factor.

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 33 of 44

Report No.: FCS202403068W02

(30MHz-1000MHz)

Temperature:

24.7

Test Voltage:

DC 6V

Test Mode:

802.11b(worst)

Relative Humidity: Phase:

61% Horizontal

No. Frequency (MHz)

Reading (dBuV)

Correct

Result

Factor(dB/m) (dBuV/m)

Limit (dBuV/m)

1 36.8953 2 82.6482 3 213.0150 4 261.9750 5 416.1791 6 721.7259

34.28 63.15 70.94 73.51 55.57 58.28

-11.83 -32.27 -32.19 -32.14 -31.98 -31.60

22.45 30.88 38.75 41.37 23.59 26.68

40.00 40.00 43.50 46.00 46.00 46.00

Margin (dB)
-17.55 -9.12 -4.75 -4.63 -22.41 -19.32

Note: 1. Margin = Result (Result =Reading + Factor )­Limit 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Remark
QP QP QP QP QP QP

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 34 of 44

Report No.: FCS202403068W02

Temperature: Test Voltage: Test Mode:

22.7 DC 6V 802.11b(worst)

Relative Humidity: Phase:

61% Vertical

No. Frequency (MHz)
1 37.8121 2 82.9385 3 187.0958 4 225.3080 5 251.1804 6 411.8240

Reading (dBuV)
48.76 67.75 66.21 68.33 67.70 58.55

Correct

Result

Limit

Factor(dB/m) (dBuV/m) (dBuV/m)

-12.44 -32.27

36.32 35.48

40.00 40.00

-32.21

34.00

43.50

-32.17

36.16

46.00

-32.15

35.55

46.00

-31.99

26.56

46.00

Margin (dB)
-3.68 -4.52 -9.50 -9.84 -10.45 -19.44

Note: 1. Margin = Result (Result =Reading + Factor )­Limit 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Remark
QP QP QP QP QP QP

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 35 of 44

Report No.: FCS202403068W02

(1GHz~25GHz) Restricted band and Spurious emission Requirements 802.11b(Worst)-Low

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 36 of 44
802.11b(Worst)-Middle

Report No.: FCS202403068W02

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 37 of 44
802.11b(Worst)-High

Report No.: FCS202403068W02

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

802.11 b low CH

Page 38 of 44

Report No.: FCS202403068W02

802.11 b High CH

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

802.11 g Low CH

Page 39 of 44

Report No.: FCS202403068W02

802.11 g High CH

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

802.11 N 20 Low CH

Page 40 of 44

Report No.: FCS202403068W02

802.11 N 20 High CH

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 41 of 44

Report No.: FCS202403068W02

8. ANTENNA REQUIREMENT

8.1 STANDARD REQUIREMENT For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And according to FCC 47 CFR Section 15.247 (b), if transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi.
8.2 RESULT The antennas used for this product are FPC antenna and other than that furnished by the responsible party shall be used with the device, the maximum peak gain of the transmit antenna is 2.49dBi.

END OF THE REPORT

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com



Related FCC IDs:

Search Any Device: