ELECTROMAGNETIC COMPATIBILITY (EMC)
Merikari Jari
Test Report 1
Nanoleq AG OXA1 Wellness Product 2A8RQOXA1 2A8RQOXA1 oxa1
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 15 Pages, 828.01KB
Document DEVICE REPORTGetApplicationAttachment.html?id=6281672Reference number: HELEM2207000317-1 Page 1 of 15 Test Report Electromagnetic Compatibility (EMC) HELEM2207000317-1 TESTS ACCORDING TO FCC PART 15 B AND ISED CANADA REQUIREMENTS Equipment Under Test: Model: Type: Trademark: Manufacturer / Customer: FCC Rule Part: IC Rule Part: Breathing sensor and smart garment Oxa1 - OXA Nanoleq AG Hofwisenstrasse 50 A 8153 Rümlang Switzerland FCC CFR 47 Part 15 Subpart B, Class B ICES-003 Issue 7, Class B Date: Issued by: 14 November 2022 Henri Mäki Testing Engineer Date: Checked by: 14 November 2022 Rauno Repo Senior EMC Specialist These test results are valid for the tested unit only. This report shall not be reproduced, except in full, without a written permission of SGS Fimko. TABLE OF CONTENTS Reference number: HELEM2207000317-1 Page 2 of 15 Table of Contents TABLE OF CONTENTS ................................................................................................................................. 2 GENERAL REMARKS ................................................................................................................................... 3 Disclaimer ................................................................................................................................................. 3 RELEASE HISTORY...................................................................................................................................... 4 PRODUCT DESCRIPTION ............................................................................................................................ 5 Equipment Under Test (EUT) .................................................................................................................... 5 General description ................................................................................................................................... 5 Samples and modifications........................................................................................................................ 5 Ports and cables ....................................................................................................................................... 5 Peripherals ............................................................................................................................................... 6 TEST CONDITIONS ...................................................................................................................................... 7 Operation modes ...................................................................................................................................... 7 Emission Measurement Uncertainty .......................................................................................................... 7 SUMMARY OF TESTING .............................................................................................................................. 8 EMISSION TESTS......................................................................................................................................... 9 Conducted Emissions In The Frequency Range 150 kHz 30 MHz........................................................... 9 Radiated Emissions In The Frequency Range 30 MHz 12.5 GHz............................................................ 11 TEST EQUIPMENT ....................................................................................................................................... 15 Conducted emissions ................................................................................................................................ 15 Radiated emissions................................................................................................................................... 15 Reference number: HELEM2207000317-1 Page 3 of 15 Disclaimer GENERAL REMARKS Disclaimer This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company's findings at the time of its intervention only and within the limits of Client's instructions, if any. The Company's sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. RELEASE HISTORY Version 1.0 1.1 Changes Initial release EUT model name corrected Reference number: HELEM2207000317-1 Page 4 of 15 Release History Issued 10 November 2022 14 November 2022 PRODUCT DESCRIPTION Equipment Under Test (EUT) Reference number: HELEM2207000317-1 Page 5 of 15 Product Description General Product Description Trademark Model Type Serial number Power input port type Rated voltage Rated current Rated frequency Rated power EUT Highest operation freq. Hardware Version (if any) Software Version (if any) Mechanical size of the EUT (mm) Parallel models Radio module or chip EUT information Breathing sensor and smart garment OXA Oxa1 Battery operated (charging via USB-C) DC Insight SiP ISP1507 The EUT was tested as a tabletop unit. General description The equipment under test is a breathing sensor and a smart garment. The sensor monitors heartbeat, breath, and temperature change in real-time. The garment includes a breathing band to provide breathing rate and depth, and electrodes to provide heart rate and heart rate variability. The sensor includes a Bluetooth 5.0 Low Energy module in order to connect to a mobile device for guided breathing sessions. Samples and modifications No. Name 1 EUT Description Sensor (sample number 3323) and garment (bra). Sensor has been modified to have Vdd power wires outside the enclosure. Ports and cables Cable / Port USB-C Description Used for charging Peripherals Peripheral AC/DC adapter Reference number: HELEM2207000317-1 Page 6 of 15 Product Description Description / Usage Huawei HW-050100E01. Charging the EUT during Conducted emissions test. Provided by the laboratory. Reference number: HELEM2207000317-1 Page 7 of 15 Test Conditions TEST CONDITIONS Configuration of the EUT was made to correspond to the actual assembling conditions as far as possible. The sensor was either attached to the garment or peripheral AC/DC adapter (input voltage 120 V, 60 Hz). The Bluetooth radio of the sensor was transmitting at the three BLE advertising channels (2402, 2426, 2480 MHz). Figure 1: Test setup block diagram Operation modes During the tests the EUT was in the following operation modes: Mode Description 1 Sensor attached to garment 2 Charging the sensor Emission Measurement Uncertainty The uncertainties comply with CISPR 16-4-2 ed.2 requirements (Ulab < Ucispr). SUMMARY OF TESTING Reference number: HELEM2207000317-1 Page 8 of 15 Summary of Testing Test Specification FCC CFR 47 15/B §15.107, ICES-003 3.2.1 FCC CFR 47 15/B §15.109, ICES 003 3.2.2 Description of Test Conducted emissions, Class B Radiated emissions, Class B Result PASS PASS Decision rule used for the emission tests are defined in standard CISPR 16-4-2 / EN 55016-4-2 clause 4.2 Test Facility Testing Laboratory / address: FCC designation number: FI0002 ISED CAB identifier: T004 Test Site: SGS Fimko Ltd Takomotie 8 FI-00380, HELSINKI FINLAND K10LAB, ISED Canada registration number: 8708A-1 K5LAB, ISED Canada registration number: 8708A-2 T10LAB Reference number: HELEM2207000317-1 Page 9 of 15 Conducted Emissions In The Frequency Range 150 kHz 30 MHz EMISSION TESTS Conducted Emissions In The Frequency Range 150 kHz 30 MHz Standard: Tested by: Date: Temperature: Humidity: Barometric pressure: Measurement uncertainty: ANSI C63.4-2014 PKA 7 November 2022 24 °C 44 %RH 1008 mbar 2.9 dB Level of confidence 95 % (k = 2) FCC Rule: 15.107(a) ICES-003: 3.2.1 Test Plan Conducted disturbance voltage was measured with an artificial main network from 150 kHz to 30 MHz with a resolution bandwidth of 9 kHz. Measurements were carried out with peak and average detectors from the phase(s) and neutral lines of the power supply cable. The EUT was working as described in the section "Test Conditions" using Operation mode 2. Frequency of emission (MHz) 0.15 0.5 0.5 5 5 30 Quasi-peak 66 to 56 * 56 60 Conducted limit (dBµV) Average 56 to 46 * 46 50 * Decreases with the logarithm of the frequency. Test results Reference number: HELEM2207000317-1 Page 10 of 15 Conducted Emissions In The Frequency Range 150 kHz 30 MHz Full Spectrum Level in dBµV 80 70 FCC Part 15 Class B Voltage on Mains QP 60 FCC Part 15 Class B Voltage on Mains AV 50 40 30 20 10 0 150k 300 400 500 800 1M 2M 3M 4M 5M 6 Frequency in Hz 8 10M 20M 30M Preview Result 2-AVG FCC Part 15 Class B Voltage on Mains QP Final_Result QPK Preview Result 1-PK+ FCC Part 15 Class B Voltage on Mains AV Final_Result CAV Figure 2: Graphical presentation of conducted emissions Table 1: Test results for conducted emissions Frequency (MHz) 0.198000 0.500500 0.522500 1.032750 9.212000 22.600750 QuasiPeak (dBµV) 26.24 28.42 --19.42 22.08 20.33 CAverage (dBµV) ----14.54 ------- Limit (dBµV) 63.69 56.00 46.00 56.00 60.00 60.00 Margin (dB) 37.45 27.58 31.46 36.58 37.92 39.67 Meas. Time (ms) 15 x 1000.0 15 x 1000.0 15 x 1000.0 15 x 1000.0 15 x 1000.0 15 x 1000.0 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 Corr. (dB) 9.7 9.7 9.7 9.8 10.2 10.6 Correction factor (dB) in the final result tables contains the sum of the transducers (cables + LISN). QuasiPeak and Average values are the measured values corrected with the correction factor. Reference number: HELEM2207000317-1 Page 11 of 15 Radiated Emissions In The Frequency Range 30 MHz 12.5 GHz Radiated Emissions In The Frequency Range 30 MHz 12.5 GHz Standard: Tested by: Date: Temperature: Humidity: Barometric pressure: Measurement uncertainty: ANSI C63.4-2014 HEM 7 November 2022 24 °C 44 %RH 1008 hPa 4.9 dB (30 200 MHz) 4.1 dB (200 1 000 MHz) 4.3 dB (1 18 GHz) Level of confidence 95 % (k = 2) FCC Rule: 15.109(a) ICES-003: 3.2.2 Test plan The radiated emission measurements were done within a semi anechoic screened chamber. Additional floor absorbers were used on the floor between the EUT and receiving antenna in radiated emission test above 1 GHz. The EUT was placed on a table 0.8 m above the reflecting ground plane.The measurement distance was 3 meters. The worst interferences were determined during measurements by rotating the turntable and adjusting the antenna height. The measurements were done in horizontal and vertical antenna polarizations. The supply voltage to the turntable was fed through the filter. The EUT was working as described in the section "EUT Test Conditions" using Operation modes 1 and 2. Above 1 GHz only the results with Operation mode 1 are presented. Radiated measurement settings Preliminary testing: Turntable movement: Turntable position: Antenna movement: Antenna height: Antenna polarization: Final testing: Turntable movement: Turntable position: Antenna movement: Antenna height: Antenna polarization: 30° step (30-1000 MHz), 0° to 330° (30-1000 MHz), 1.5 m step 1.0 m to 4.0 m Vertical and horizontal 15° step (1-12.5 GHz) 0° to 345° (1-12.5 GHz) Continuous ± 30° (30-1000 MHz), Continuous ± 1.5 m Vertical and horizontal ± 15° (1-12.5 GHz) Test results 60 Reference number: HELEM2207000317-1 Page 12 of 15 Radiated Emissions In The Frequency Range 30 MHz 12.5 GHz Full Spectrum 50 Level in dBµV/m 40 30 20 10 0 30M 50 60 80 100M 200 300 400 500 800 1G Frequency in Hz Preview Result 1H -PK+ Preview Result 1V-PK+ FCC Part 15 Class B Electric Field Strength 3 m QP Final_Result QPK Final_Result PK+ Figure 3: Graphical presentation of radiated emissions (30-1000 MHz), Operation mode 1 Table 2: Test results for radiated emissions (30-1000 MHz), Operation mode 1 Frequency (MHz) 832.690000 841.390000 QuasiPeak (dBµV/m) 24.99 29.04 Limit (dBµV/m) 46.00 46.00 Margin (dB) 21.01 16.96 Meas. Time (ms) 15 x 1000.0 15 x 1000.0 Bandwidth (kHz) 120.000 120.000 Height (cm) Pol 294.0 H 286.0 H Azimuth (deg) 195.0 181.0 Corr. (dB/m) 30.3 30.3 Correction factor (dB) in the final result tables contains the sum of the transducers (antenna + cables). QuasiPeak values are the measured values corrected with the correction factor. Reference number: HELEM2207000317-1 Page 13 of 15 Radiated Emissions In The Frequency Range 30 MHz 12.5 GHz Full Spectrum 60 50 Level in dBµV/m 40 30 20 10 0 30M 50 60 80 100M 200 Frequency in Hz Preview Result 1H -PK+ Preview Result 1V-PK+ FCC Part 15 Class B Electric Field Strength 3 m QP Final_Result QPK Final_Result PK+ 300 400 500 800 1G Figure 4: Graphical presentation of radiated emissions (30-1000 MHz), Operation mode 2 Table 3: Test results for radiated emissions (30-1000 MHz), Operation mode 2 Frequency (MHz) 39.780000 64.090000 QuasiPeak (dBµV/m) 14.23 18.74 Limit (dBµV/m) 40.00 40.00 Margin (dB) 25.77 21.26 Meas. Time (ms) 15 x 1000.0 15 x 1000.0 Bandwidth (kHz) 120.000 120.000 Height (cm) Pol Azimuth (deg) 100.0 V 315.0 100.0 V 149.0 Corr. (dB/m) 17.1 17.4 Correction factor (dB) in the final result tables contains the sum of the transducers (antenna + cables). QuasiPeak values are the measured values corrected with the correction factor. Reference number: HELEM2207000317-1 Page 14 of 15 Radiated Emissions In The Frequency Range 30 MHz 12.5 GHz Full Spectrum 90 80 Level in dBµV/m 70 60 50 40 30 20 1G 2G 3G 4G 5G 6 8 Frequency in Hz Preview Result 2-AVG Preview Result 1-PK+ FCC Part 15 Class B Electric Field Strength 3 m PK FCC Part 15 Class B Electric Field Strength 3 m AV Final_Result PK+ Final_Result CAV 12.5G Figure 5: Graphical presentation of radiated emissions (1-12.5 GHz), Operation mode 1 Table 4: Test results for radiated emissions (1-12.5 GHz), Operation mode 1 Frequency (MHz) MaxPeak (dBµV/m) CAverage (dBµV/m) Limit (dBµV/m) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) 12492.800000 58.21 --- 73.90 15.69 15 x 1000.0 1000.000 294.0 V 266.0 27.0 12499.400000 --- 44.75 53.90 9.15 15 x 1000.0 1000.000 123.0 V 10.0 27.1 Correction factor (dB) in the final result tables contains the sum of the transducers (antenna + amplifier + cables). MaxPeak and CAverage values are the measured values corrected with the correction factor. Note: the emissions within 2400-2483.5 MHz ISM band are caused by the Bluetooth radio of the sensor (frequencies 2402, 2426, and 2480 MHz). TEST EQUIPMENT Conducted emissions Description EMI TEST RECEIVER LISN POWER SUPPLY TEST SOFTWARE Radiated emissions Description ANTENNA ANTENNA ANTENNA MAST ATTENUATOR ATTENUATOR EMI TEST RECEIVER MAST & TURNTABLE CONTROLLER POWER SUPPLY RF PREAMPLIFIER TEST SOFTWARE TURNTABLE Manufacturer ROHDE & SCHWARZ ROHDE & SCHWARZ CALIFORNIA INSTR. ROHDE & SCHWARZ Manufacturer SCHWARZBECK EMCO MATURO PASTERNACK PASTERNACK ROHDE & SCHWARZ MATURO CALIFORNIA INSTR. CIAO ROHDE & SCHWARZ MATURO NCR = No Calibration Required Reference number: HELEM2207000317-1 Page 15 of 15 Test Equipment Model ESW26 ENV216 5001 iX Series II EMC-32 Identifier inv. 10679 inv. 9611 inv. 7826 - Cal. Date 2022-06-20 2022-02-02 NCR - Cal. Due 2023-06-20 2023-02-02 NCR - Model VULB 9168 3117 TAM 4.0E 10 dB, DC-40 GHz PE 7004-4 (4dB) ESW26 NCD 5001 iX Series II CA118-3123 EMC-32 DS430 UPGRADED Identifier inv. 8911 inv. 7293 inv. 10181 sn. A1 inv. 10126 inv. 10679 inv. 10183 inv. 7826 inv. 10278 inv. 10182 Cal. Date 2020-11-04 2022-06-16 NCR 2021-04-20 2021-03-30 2022-06-20 NCR NCR 2022-09-21 NCR Cal. Due 2022-11-04 2024-06-16 NCR 2023-04-20 2023-03-30 2023-06-20 NCR NCR 2023-09-21 NCR END OF REPORT
Related FCC IDs:
- 2A8RQOXA1 - Nanoleq AG Wellness Product [OXA1] Microsoft Word for Microsoft 365; modified using SignServer