Philips UV-C disinfection desk lamp User Manual
Philips UV-C disinfection desk lamp
User manual
This user manual provides important information on the application and operation of this UV-C device. You should always use and store this UV-C device in accordance with this user manual. Caution!
- No person or animal should be present in the room at the time of usage, due to high risk of harm to eyes and skin.
- This UV-C device is not approved and/or certified as a medical device.
- This UV-C device is intended to be used for the disinfection of the surfaces of objects other than medical devices.
- The UV-C device cannot be used to disinfect the surfaces of medical devices (such as medical devices in a room, surgical masks and/or surgical respirators).
- The UV-C device cannot be used in medical settings.
- The UV-C device cannot be used for disinfection of human skin.
- Do not heavily bend or drag the cord, to prevent fire and electric shock. The cord is not replaceable.
- Do not use the damaged cord.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
- Do not use the UV-C device as normal lighting.
- This UV-C device should only be used in a stable upright position.
- Do not use this UV-C device when it leans, is upside down or has fallen from a flat surface.
- This UV-C device should be put in the center of the room, on the floor or on a table (with a height no more than 1.2 meter).
- The disinfection effect is dependent on the time of exposure to UV-C light.
- Keep it well stored when it is not working to prevent causing harm to eyes and skin of humans and animals.
- Always store the UV-C device in the supplied presentation case.
- This UV-C device should not be opened or dismantled.
- Switch the power off when cleaning the product .
- The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
- This UV-C device only works under dry conditions, its not water-proof.
Control panel
Power button, hold 3 seconds to unlock/press once to start working. Timer button, press once to choose working min. Press any button to stop working and back to lock mode. The UV-C device is locked when the LED indicators light one by one. The UV-C device doesn’t work properly when the LED indicators are in light flash mode, please contact customer service.
Operation guide
- Power on, the UV-C device is in lock mode, hold power button for at least 3 seconds to unlock.
- Press timer button to choose disinfection duration, there are 3 options, 15min., 30min. or 45min.
- Press power button to start working mode, please leave the room and close the door, and the device will start to disinfect in 30 seconds when sensor can’t detect any human or animal.
Language selection mode
- Hold both power and timer button simultaneously for 3 seconds
- Press timer button for language selection, there are 4 languages for selection: French , German, Spanish and English
- Press power button to save and exit the language selection mode
- The device will go back to lock mode when routine is completed.
- Please unplug the device when routine completes. * The sensor can detect human or animal within 5 meters radius. * When human or animal enters the 5 meters radius, the UV-C device will turn off light and switch to lock mode.
Application
Recommendation |
Bathroom / Kitchen | Bedroom |
Living room |
Disinfection time |
15 min | 30 min |
45 min |
Product Specification
Product description | UV-C disinfection desk lamp |
Input | 220-240Vac 50/60Hz |
Wattage | 24W |
UV-C device lifetime | 9000hours |
Size | 120X120X247mm |
Weight | 800g |
UV-C wavelength | 253.7nm |
effective irradiance @200mm | 660uW/cm2 |
Documents / Resources
Philips UV-C disinfection desk lamp [pdf] User Manual UV-C disinfection desk lamp | |
PHILIPS UV-C Disinfection Desk Lamp [pdf] User Manual UV-C Disinfection Desk Lamp, UV-C, Disinfection Desk Lamp | |
PHILIPS UV-C Disinfection Desk Lamp [pdf] User Manual UV-C Disinfection Desk Lamp |