Commercial Electric PRWX50-H-PC-4K-BZ 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light User Guide

Commercial-Electric-PRWX50-H-PC-4K-BZ-675-Watt-Equivalent-Integrated-LED-Bronze-Commercial-Refractor-Wall-Pack-LOGO

Commercial Electric PRWX50-H-PC-4K-BZ 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light

Safety Information

IMPORTANT This product must be installed in accordance with the applicable National Electrical Code and local building codes by a person familiar with the construction and operation of the product and the hazards involved.

PRECAUTIONS

WARNING: Before installation or servicing, turn the power off at the circuit breaker or fuse. Place tape over the circuit breaker switch and verify power is off at the light fixture. Risk of fire. Keep the lamp heads at least 3 in. (76 mm) from combustible materials. Burn hazard. Allow the light fixture to cool before touching. INFORMATION: The device is tested and found to comply with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference and, (2) this device must accept any interference received, including any interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warranty

This is a limited warranty offered by Commercial Electric for a period of five years from the date of purchase to its customers. Commercial Electric warrants to customers that the products will be free from defects in material and workmanship. The obligation of Commercial Electric under this warranty is limited to the provision of replacement of products and is extended to the original purchaser of the product on presenting valid purchase receipt or other proof of date of original purchase acceptable to Commercial Electric. A receipt is required for rendering the warranty performance. Any warranty claims without original proof of purchase would not be accepted. It should be noted that the warranty does not apply to Commercial Electric products that have been altered or repaired by unauthorized personnel, have been subjected to neglect, abuse, misuse or accident, or damages caused during shipping. Any other products not manufactured by Commercial Electric that have been supplied, installed, and/or used in conjunction with Commercial Electric products are not covered under this warranty. Any damages caused by replacements bulbs, LEDs, or corrosion or discoloration of brass components are also not covered by this warranty.

LIMITATION OF LIABILITY

In no event, Commercial Electric shall be liable for indirect, consequential, incidental or special damages, or lost profits. Commercial Electric is not liable for any claims or damage arising out of or connected with the manufacture, sale, delivery, use, maintenance and repair, or modification of Commercial Electric products, or supply of any replacement parts that exceed the purchase price of Commercial Electric products giving rise to a claim. Labor charges to remove or install the fixtures will not be accepted.

TO CLAIM

Please contact Commercial Electric customer service at 1-877-527-0313 or email [email protected] and include your name, address, and contact number, along with a copy of the purchase receipt and a brief description of the problem.

Pre-Installation

PLANNING INSTALLATION Before installing the light fixture, ensure that all parts are present. Compare parts with the Hardware Included and Package Contents sections. If any part is missing or damaged, do not attempt to assemble, install, or operate this light fixture.

SPECIFICATIONS

Lumens (Light Output) 6,500 Lumens 10,000 Lumens
Watts (Power Consumption) 50 Watts LED 80 Watts LED
Replaces 450W Incandescent 650W Incandescent
Lumens/Watts (Efficacy) 130 Lumens per watt 125 Lumens per watt
Power Requirements (Input Voltage) 120-277 VAC
Light Color (CCT) 4,000 Kelvin (Bright White)
Dimmable Dimming (When used with a 0-10V dimming switch.)
Operating Modes Dusk-to-Dawn: Automatically turns light fixture ON during night and OFF during day.   Switch-Controlled: Flip switch to turn light fixture ON and OFF. (Use included light sensor cap on fixture's light sensor to utilize this mode setting).

TOOLS REQUIRED

HARDWARE INCLUDED

Part Description Quantity
AA #8-32 x 3/4 in. Phillips head screw 2
BB Wire nut 3
CC Hex head screwdriver 1
  Clear photocell cover cap  
NOTE: Hardware not shown to actual size.

PACKAGE CONTENTS

Installation

 Shut off the electric power

Verify wall switch is in OFF position (fig 2). At the main electrical panel, turn off the circuit breaker that supplies power to the junction box you are working on (fig 3). For screw-in type fuses, unscrew the fuse that supplies power to the junction box you are working on (fig 4).

 Removing the mounting Plate

NOTE: The mounting plate tightening screw (B)  comes pre-installed on the light fixture. The tightening screw should not be completely removed. 

 Installing the Mounting Plate

FOR MOUNTING TO A JUNCTION BOX 

ConnectionsMaking Electrical

WHEN DIRECT SURFACE MOUNTING USING SIDE CONDUIT ENTRY WIRING (No junction box present) WHEN USING SIDE CONDUIT ENTRIES (No junction box present) FOR NON˜DIMMING ELECTRICAL WIRING (Follow these steps when NOT wiring to a 0-10V dimmer). TIP: Hold stripped ends near each other and align any frayed strands (do not twist wires). Push the wires into wire nut (BB) and use your fingers to twist the wire nut clockwise until tight. Check for tightness by pulling wires. NOTE: Leave purple and gray wires terminated and separated when NOT connecting to a 0-10V dimmer. DO NOT connect the purple and gray wires to any other wire unless wiring to a 0-10V dimmer. FOR ELECTRICAL WIRING TO °˜˛°V DIMMER (Follow these steps when wiring to a 0-10V dimmer.)

 Mounting the Light Fixture

Caulking Around the Light Fixture

NOTE: Failure to properly caulk around the back face of the light fixture and mounting surface could lead to water damage and is not covered under warranty. NOTE: When attaching this light fixture to an extruded surface mount junction box, caulk between the junction box and the mounting plate.

Operation

Selecting Dusk-to-Dawn or Switch- Activated Control OPTION 1: DUSK-TO-DAWN OPERATION Dusk-to-dawn operation enables the light fixture to automatically turn ON when dark outside and turn OFF when the sun rises, thus saving you energy.

TIP: To test if the light fixture and photocell work properly, run power to the fixture and cover the photocell to turn fixture ON. Shine a light into the photocell to see if fixture turns OFF. OPTION 2: SWITCH CONTROLLED Switch-controlled operation enables the light fixture to turn ON and OFF by flipping a switch that controls the electricity to the outlet powering the fixture. The light fixture will not turn ON and OFF automatically, but is manually controlled. To enable switch activated operation leave the black cap cover (D) on the photocell. (fig 16).

Care and Cleaning

Troubleshooting

Problem Possible Cause Solution
    Light does not turn ON     No power to the fixture Check if circuit breaker is tripped. Confirm wall switch is ON. Verify wiring to fixture is correct (turn
Fixture is sensing daylight Cover photocell. Wait several seconds until fixture turns ON.
    Light cycles ON and OFF continuously     Photocell light sensor is sensing reflected light Relocate light fixture to a location where there is no reflected light. OR place the black  cap  cover over the photocell and use the wall switch to turn the light fixture ON and OFF.
Light FLICKERS The light fixture is wired through an unsuitable dimmer Replace the dimmer with a 0-10V dimming switch or a standard ON/OFF wall switch.
              Light stays ON         Photocell is in a shaded area Shine a flashlight into the photocell and wait a couple minutes. If the light turns OFF, the fixture should be moved to a location with enough light in the daylight hours for the photocell to work. OR place the optional opaque cover over the photocell and use the wall switch to turn the light ON and OFF.
    Photocell is faulty   a flashlight is shone on the photocell for a few minutes, then the photocell may be faulty. Please contact customer service.
NOTE: Photocell may have a few minutes delay during troubleshooting. When testing, shine a light and/or cover the photocell and allow a few minutes for fixture to function properly.

Documents / Resources

Commercial Electric PRWX50-H-PC-4K-BZ 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light [pdf] User Guide
PRWX50-H-PC-4K-BZ, PRWX80-H-PC-4K-BZ, PRWX50-H-PC-4K-BZ 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light, 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light
Documents - commercial-electric,commercial electric – PRWX50-H-PC-4K-BZ,PRWX80-H-PC-4K-BZ
[pdf] User Manual Instructions Specifications Guide Warranty Catalog
PRWX50 H PC 4K BZ PRWX80 Instructions v3 Print 675 Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light 4000K Use and Care Manual Electric 810061323877 0810061323877 1007092281 7a154f46 8ed2 46f6 a216 dc0cdec162bc images thdstatic catalog Images 7a |||
Model No. PRWX50-H-PC-4K-BZ PRWX80-H-PC-4K-BZ USE AND CARE GUIDE POWERWALL X LED WALLPACK Questions, problems, missing parts Before returning to the store, call Commercial Electric Customer Service 8 a.m. - 7 p.m., EST, Monday Friday, 9 a.m. 6 p.m., EST, Saturday 1-877-527-0313 HOMEDEPOT.COM THAN...
lang:en score:66 filesize: 3.9 M page_count: 14 document date: 2021-11-03

tags: 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light, Commercial Electric, PRWX50-H-PC-4K-BZ, PRWX50-H-PC-4K-BZ 675-Watt Equivalent Integrated LED Bronze Commercial Refractor Wall Pack Light, PRWX80-H-PC-4K-BZ,

Search Any Device: