TE connectivity PE0S0SS6B P Series Versatile Power Entry Module with Small Footprint Instruction Manual

TE-CONNECTIVITY-LOGO

TE connectivity PE0S0SS6B P Series Versatile Power Entry Module with Small Footprint

TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-PRODUCT-IMAGE TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-01 P Series The P series CHAMELEON power entry module offers the most popular features in a small footprint design As the first l0A module to provide all five power entry functions in one compact design, the chameleon module readily adapts to its environment and the needs of international markets.

The CHAMELEON module's compact design and modular construction allows selection of the required power entry feature - without altering the panel cutout. And the CHAMELEON module, with its optional adapters, will fit several common panel cutouts. Filter Types The CHAMELEON module has four filter and one non-filtered option: S models provide an extended performance two element circuit EMI filter, with attenuation similar to the EEB Series power inlet filter. It offers protection for general purpose applications with stray Line to Ground and Line to Line noise that must be attenu­ated at the power inlet. These filters have limited leakage current and are available in current ratings of 3, 6 and lOA. H models provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment. L models feature a high performance medical filter designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and l0A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. Z models provide a high performance three element differential mode circuit filter, with extended EMI attenuation similar to the M Series Z models, to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emis­sions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. For minimum depth behind the panel, see the M Series B models are non-filtered and incorporate an inter­connection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with an IEC connector and an optional switch to reduce external wiring. Compatible with the A or B RFI shield options.

Ordering Information

Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Note: For any option where shown as "O" use the digit ZERO (0) not the letter (0). TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-02 Extender Option

Input Voltage Select Filter Type Shield Options TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-3 Notes:
  1. L Series extender cannot be added to units with a shield. No style of extender can be added to units with B or C shields.
  2. Dual voltage options are not available with L or Z Filter Types
  3. When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B)
  4. High performance versions (Lor Z filter types) are available with any switch or fuse option but only in 6 or lOA with horizontal (PE) or vertical (PM) mounting ears, single voltage (0),complete shield (C) and no extenders For alternative switch orientation options, contact technical support or your Corcom product sales representative.
The part number PS0SXSS6B would represent: P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S) general purpose filter (S) for 6A (6) with a B shield (B). Voltage Selection P series power entry modules include the voltage selector integral with the fuse holder. Three voltage selection options are each supported by one of three different fuse holders. The fifth digit of the part number specifies which of the three fuse holders is included to provide the desired voltage selection. The single voltage fuse holder (option "0") has no voltage indication markings. The dual voltage options select 115V or 230V by removing the fuse holder, flip­ping it over, and reinstalling it. Voltage selection is indicated through a window in the P Series door. The "SMPS" fuse holder (option "S") jumpers two inde­pendent P Series terminals to indicate 230V operation to a switching mode power supply. The "PRSR" parallel/serial fuse holder (option "X") connects the windings of the equipment's dual primary transformer (not included) to step down the voltage or double up the current. The markings on the voltage selection fuse holders also remind the user to install the appropriate fuse for the current at the selected voltage. Input Voltage Selection Schemes S - "SPMS" Jumper TypeTE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-04 X - "PRSR" Parallel / Serial Type for Dual Primary TransformerTE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-05Note 1: Additional jumper wiring is required if a filter or interconnection module is not used. Note 2: Location of optional filter. Additional jumper wiring is required if a filter or interconnection block is not used. Shield Options The P series offers several RF shield options. The metal shield, optional on S, H and B filtered models, provides shielding from radiated emissions and provides an RF ground for the filter to the panel. This shield is available in two versions; a shield of the filter components (designated by an A as the final digit) and a complete shield (designated by B as the final digit). The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from RFI coupling. This shield allows the use of the C or J extender. The B shield covers the entire power entry module with metal, protecting the filter from RFI coupling, and covering the mounting cut-out to block RFI entering or leaving the equipment. The B shield cannot be used with any extender. A complete metal enclosure is integral to both the high performance L and Z models, and must be spec­ified by a C in the part number's final digit. This option is only available with the L or Z models. TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-06Fuse holder Another feature of the P series power entry module is the versatile fusing arrangement. The fuse holder can hold two 1/4" x 1-1/4" (3AG) or 5 x 20mm (metric) fuses. Single fusing is supported with a conversion clip that shorts one of the two fuse positions, and is designated by an S in the sixth part number digit. A module designated for a single fuse may be reconfig­ured by the manufacturer or the user to accept two fuses by simply removing the shorting clip. For appli­cations intended for dual fusing, specify a D in the sixth part number digit. TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-07Interconnection Block Installation of the unfiltered versions of the P series requires wiring of the IEC socket terminals to the optional switch and the switch to the fuse holder. Labor can be eliminated by ordering the module with an interconnection block. This feature, desig­nated by "BX" in the seventh and eighth digits, pre wires the module so that only connection to the equipment must be done during installation. The interconnection block includes a plastic case to prevent access to the internal connections. The dimensions of this alternative are the same as the filtered versions. TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-10 Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cordTE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-08 PAlOO: Power interconnect assembly For voltage select models. Designed for use with either filtered or non-filtered units, 6" wire leads TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-09

PA400 J Series Extender

Specifications

Maximum leakage current each Line to Ground: TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-23 Electrical Schematics TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-12 Case Styles Front View TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-13Typical Dimensions:

Extender Options TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-14 Standard Models - Side and Rear View TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-15Typical Dimensions: High Performance Models - Side and Rear View TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-16 Typical Dimensions:  Shield Options  TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-17 NOTE: Shields can only be used with filtered models. B shield may not be used with J or C extender Recommended Panel Cutout TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-18 NOTE: For snap-in applications, the ''A" sides must have a .020 [508] radius on the installation side. Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer's application parameters. Snap-in models allow for front mounting only Not recommended for use in plastic panels. TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-19 *For panel thickness of 0.037 - 0.079 [0.787 - 2.07] only Use 2.273 [56.27] for panel thickness of 0.083 - 0.774 [2.0 - 2.90]

Performance Data

Typical Insertion Loss  --- Common Mode/ Asymmetrical (L-G) Measured in closed 50 Ohm system --- Differential Mode/ Symmetrical (L-L) S ModelsTE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-20 TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-21

Minimum Insertion Loss

Measured in closed 50 Ohm system TE-connectivity-PE0S0SS6B-P-Series-Versatile-Power-Entry-Module-with-Small-Footprint-22

Documents / Resources

TE connectivity PE0S0SS6B P Series Versatile Power Entry Module with Small Footprint [pdf] Instruction Manual
PE0S0SS6B P Series Versatile Power Entry Module with Small Footprint, PE0S0SS6B, P Series, Versatile Power Entry Module with Small Footprint
Documents - te-connectivity,te connectivity – PE0S0SS6B
[pdf]
Statement of Compliance Tyco Electronics Rohs TE Connectivity Corcom PE0S0SS6B Connectors IBS rohs certificate sigma octopart 14495352 |||
Statement of Compliance Requested Part 27 March 2013 1-1609104-7 Part 1 of 1 PE0S0SS6B=C1165 Part Status: Obsolete EU RoHS/ELV Code: Not EU RoHS or ELV Compliant Solder Process Capability Code: Not applicable for solder process capability China RoHS: Not reviewed for China RoHS compliance Exe...
lang:en score:29 filesize: 108.68 K page_count: 2 document date: 2013-03-27
[pdf] Datasheet Accessories
CORCOM TE CONNECTIVITY product 8 6609940 7 datasheet te usa en |||
PM0S0DS6B Multi-Function Inlet Filters, Power Entry Filtered/Unfiltered , Single AC Input, DPST, ... 05203-8 CRIMP SNAP RCPT ASSY,SIZE 1 TE Part #1-66504-0 SOCKET CONTACT, 20 DF TE Part #1-6609104-7 PE0S0SS6B=C1165 For support call 1 800 522 6752 07/30/2023 07:27AM Page 3 PM0S0DS6B Multi-Fu...
lang:en score:19 filesize: 201.41 K page_count: 5 document date: 2023-07-30
[pdf] Datasheet
Digital Datasheet 1 66399 AMP Power Contacts TE Connectivity product datasheet te usa en |||
1-66399-1 Power Contacts, Contact, Tin, 24 20 AWG Wire Size, .2 .6 mm Wire Size, Wire 1-66399- ... rt #216165-1 26P.HDP22 REC.ASSY. TE Part #3-641534-2 02P MTA100 CONN ASSY LF TE Part #1-6609104-7 PE0S0SS6B=C1165 TE Part #52421-3 TERMINAL,PIDG SPR SPD 16-14 8 TE Part #1-206062-5 CABLE CLAMP KIT...
lang:en score:18 filesize: 251.26 K page_count: 5 document date: 2023-05-25
[pdf] Datasheet
Digitales Datenblatt RR03J120RTB Neohm Steckbare Widerstände TE Connectivity product 6 1879354 3 datasheet te de |||
RR03J120RTB 120 , Metal Film, Power Resistor, 5 , 15 x 5 mm, 2 Termination, Ammo Packed, 3 RR03J120 ... Teilenr.:6609070-5 36FCD10 J0=F7753 TE Teilenr.:4-1622820-8 3520 470R 5 TE Teilenr.:1-6609104-7 PE0S0SS6B=C1165 TE Teilenr.:1734328-2 Mini USB AB R/A,Rcpt,SMT,T R TE Teilenr.:1892302-1 MBXL R/A ...
lang:de score:18 filesize: 105.88 K page_count: 4 document date: 2023-10-09
[pdf] Specifications Datasheet Dimension Guide Documentation
Digital Datasheet R85049 90 21N03 RAYCHEM Unscreened Backshells Adapters TE Connectivity product CW4629 000 datasheet te usa en |||
R85049/90-21N03 Unscreened Backshells Adapters, Right Angle, Aluminum Alloy, Electroless Nickel, R ... Adapters 137 Unscreened Backshells Adapters 267 Customers Also Bought TE Part #1-6609104-7 PE0S0SS6B=C1165 TE Part #202174-5 GUIDE SOC. ASSY. 104 CTR. FSTN TE Part #YDTS26F25-61PNV001 PLUG ...
lang:en score:18 filesize: 198.16 K page_count: 3 document date: 2023-05-18
[pdf] Datasheet
Digital Datasheet 1050524 1 AMP SMA Coax Connectors TE Connectivity product datasheet te usa en |||
1050524-1 SMA RF Interface, Plug, 50 , RG 402 Semi-Rigid, Threaded, 18 GHz Operating 1050524-1 Frequ ... Also Bought TE Part #879222-000 Bulbous Heat Shrink Boots: Lipped, Straight TE Part #1-6609104-7 PE0S0SS6B=C1165 TE Part #1996771-1 SMPM STR CBL JACK TE Part #7-1393117-9 KUP-14A15-24=KU TE Part...
lang:en score:18 filesize: 682.09 K page_count: 6 document date: 2023-05-25
[pdf] Datasheet
Datasheet 104068 4 by TE Connectivity Wire to Board Connectors Avnet Asia Pacific product datasheet te usa en |||
104068-4 PCB Mount Header, Vertical, Board-to-Board, 40 Position, 1.27 mm .05 in Centerline, 104 ... hrough Hole - Solder, AMPMODU System 50 TE Part #1393258-8 V23047-A1018-A501 TE Part #1-6609104-7 PE0S0SS6B=C1165 TE Part #4-1393240-8 RT334024 TE Part #532448-9 HDI PIN ASSY 4 ROW 240 POS TE Par...
lang:en score:17 filesize: 140.62 K page_count: 5 document date: 2024-02-15
[pdf] Datasheet Accessories
TE Corcom s P Series Distributor Sager Electronics te corcom p series datasheet sager resources common userfiles file Datasheets |||
CORCOM P SERIES MULTI-FUNCTION INLET FIL CORCOM P SERIES MULTIFUNCTION INLET FIL Corcom Corcom P V ... l .187 FASTON 250 VAC Yes IEC 320/C-14 Single EU RoHS Compliant EU ELV Compliant Corcom Corcom P PE0S0SS6B=C1165 1-6609104-7 Power Entry Module Single Single AC DPST Complete Shield 250 A 500 A 6 A...
lang:en score:13 filesize: 352.79 K page_count: 9 document date: 2021-02-23

tags: P series, PE0S0SS6B, PE0S0SS6B P Series Versatile Power Entry Module with Small Footprint, TE connectivity, Versatile Power Entry Module with Small Footprint,

Search Any Device: