TEMPSTAR CSA6 Split System Air Conditioner Instruction Manual

TEMPSTAR CSA6 Split System Air Conditioner logo

TEMPSTAR CSA6 Split System Air Conditioner

TEMPSTAR CSA6 Split System Air Conditioner product These instructions must be read and understood completely before attempting installation. instructions must be read and understood completely before attempting installation.

Safety Labeling and Signal Labeling and Signal Words

The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and throughout this manual and other manuals that may apply to the product. DANGER, WARNING, CAUTION, and NOTE

Signal Words in Manuals The signal word WARNING is used throughout this manual in the following manner: WARNING The signal word CAUTION is used throughout this manual in the following manner: CAUTION Signal Words on Product Labeling Signal words are used in combination with colors and/or pictures on product labels. WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury and/or death. Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. CAUTION CUT HAZARD Failure to follow this caution may result in personal injury Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts.

INSTALLATION INSTRUCTIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory−authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and current editions of the National Electrical Code ( NEC ) NFPA 70. In Canada, refer to current editions of the Canadian electrical code CSA 22.1. Recognize safety information. This is the safety−alert symbol When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety−alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

INSTALLATION RECOMMENDATIONS

NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.

  1. Locate unit away from windows, patios, decks, etc. where unit operation sound may disturb customer.
  2. Ensure that vapor and liquid tube diameters are appropriate for unit capacity.
  3. Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.
  4. Leave some slack between structure and unit to absorb vibration.
  5. When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon−based caulk. (See Fig. 1.)
  6. Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls.
  7. Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing.(See Fig. 1.)
  8. Ensure that tubing insulation is pliable and completely surrounds vapor tube.
  9. When necessary, use hanger straps which are 1 in. (25.4 mm) wide and conform to shape of tubing insulation. (See Fig. 1.)
  10. Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.
Figure 1 Connecting Tube Installation TEMPSTAR CSA6 Split System Air Conditioner 01 Outdoor unit contains system refrigerant charge for operation with AHRI rated indoor unit when connected by 15 ft. (4.57 m) of field−supplied or factory accessory tubing. For proper unit operation, check refrigerant charge using charging information located on control box cover and/or in the Check Charge section of this instruction. IMPORTANT: Maximum liquid−line size is 3/8−in. OD for all residential applications including long line. IMPORTANT: Always install the factory−supplied liquid−line filter drier. Obtain replacement filter driers from your distributor or branch.

INSTALLATION

WARNING UNIT OPERATION AND SAFETY HAZARD Failure to follow this warning could result in personal injury or equipment damage. R−410A refrigerant systems operate at higher pressures than standard R−22 systems. Do not use R−22 service equipment or components on R−410A refrigerant equipment. Specifications for this unit in residential new construction market require the outdoor unit, indoor unit, refrigerant tubing sets, metering device, and filter drier listed in presale literature. There can be no deviation. Check Equipment and Job Site Unpack Unit Move to final location. Remove carton taking care not to damage unit. Inspect Equipment File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit corner panel. It contains information needed to properly install unit. Check rating plate to be sure unit matches job specifications. Install on a Solid, Level Mounting Pad If conditions or local codes require the unit be attached to pad, tie down bolts should be used and fastened through knockouts provided in unit base pan. Refer to unit mounting pattern in Fig. 2 to determine base pan size and knockout hole location For hurricane tie downs − contact your local distributor for details and PE (Professional Certification), if required by local authorities. On rooftop applications, mount on level platform or frame. Place unit above a load−bearing wall and isolate unit and tubing set from structure. Arrange supporting members to adequately support unit and minimize transmission of vibration to building. Consult local codes governing rooftop applications. Roof mounted units exposed to winds may require wind baffles. Consult the Low−Ambient pressure switch installation instructions for wind baffle construction. NOTE: Unit must be level to within ±2 (±3/8 in./ft..) per compressor manufacturer specifications.

Clearance Requirements

When installing, allow sufficient space for airflow clearance, wiring, refrigerant piping, and service. Allow 30 in. (762 mm) clearance to service end of unit and 48 in. (1219.2 mm) above unit. For proper airflow, a 6 in. (152.4 mm) clearance on one side of unit and 12 in. (304.8 mm) on all remaining sides must be maintained. Maintain a distance of 24 in. (609.6 mm) between units. Position so water, snow, or ice from roof or eaves cannot fall directly on unit. Figure 2 Tie Down KnockoutsTEMPSTAR CSA6 Split System Air Conditioner 02

UNIT BASE PAN Dimension TIEDOWN KNOCKOUT LOCATIONS in. (mm)
A B C
31–1/2 X 31–1/2 9–1/8 (231.8) 6–9/16 (166.7) 24–11/16 (627.1)
35 X 35 9–1/8 (231.8) 6–9/16 (166.7) 28–7/16 (722.3)
  On rooftop applications, locate unit at least 6 in. (152.4 mm) above roof surface. Operating Ambient The minimum outdoor operating ambient in cooling mode is 55F (12.78C) without low ambient cooling enabled, and the maximum outdoor operating ambient in cooling mode is 125F (51.67C).

Make Piping Connections

WARNING PERSONAL INJURY AND ENVIRONMENTAL HAZARD Failure to follow this warning could result in personal injury or death. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow−control devices, including solenoid valves. CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Do not leave system open to atmosphere any longer than minimum required for installation. POE oil in compressor is extremely susceptible to moisture absorption. Always keep ends of tubing sealed during installation. If ANY refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise at service valve. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further special consideration. Do not bury lines more than 36 in. (914.4 mm). Outdoor units may be connected to indoor section using accessory tubing package or field−supplied refrigerant grade tubing of correct size and condition. For tubing requirements beyond 80 ft/24.38 m, substantial capacity and performance losses can occur. Following the recommendations in the Long Line Applications Guideline for Split−System Air Conditioners and Heat Pumps will reduce these losses. Refer to Table 1 for accessory requirements. Refer to Table 2 for field tubing diameters. There are no buried−line applications greater than 36 in. (914.4 mm). If refrigerant tubes or indoor coil are exposed to atmosphere, they must be evacuated to 500 microns to eliminate contamination and moisture in the system. Outdoor Unit Connected to Factory Approved Indoor Unit Outdoor unit contains correct system refrigerant charge for operation with factory approved AHRI rated indoor unit when connected by 15 f t . ( 4 .57 m) of field−supplied or factory−accessory tubing, and factory supplied filter drier. Check refrigerant charge for maximum efficiency. Table 1 − Accessory Usage

    Accessory REQUIRED FOR LOWAMBIENT COOLING APPLICATIONS (Below 55 F / 12.8 C)   REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m)
Crankcase Heater Yes Yes
Compressor Start Assist Capacitor and Relay Yes Yes
Evaporator Freeze Thermostat Yes No
Liquid Line Solenoid Valve No See Long Line Applications Guideline
Lowambient Pressure Switch Yes No
Support Feet Recommended No
Thermal Expansion Valve (TXV) Hard Shutoff Yes Yes
Winter Start Control Yes No
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Long Line Applications Guideline Table 2 − Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (In.)
UNIT SIZE LIQUID RATED VAPOR up to 80 ft. (24.38 m)*
Connection and Tube Diameter Connection Diameter Rated Tube Diameter
18, 24, 30, 3/8 3/4 3/4
36, 42, 48 3/8 7/8 7/8
60 3/8 7/8 1−1/8
* Units are rated with 25 ft. (7.6 m) of lineset. See Specification sheet for performance data when using different size and length linesets. Notes:
  1. Do not apply capillary tube or fixed orifice indoor coils to these units.
  2. For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 35 ft. (10.7 m) vertical differential 250 ft. (76.2 m) Total Equivalent Length), refer to the Long Line Applications Guideline.

Install Liquid Line Filter Drier Indoor

CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Installation of filter drier in liquid line is required. Filter drier must be wrapped in a heat−sinking material such as a wet cloth while brazing. Refer to Fig. 3 and install filter drier as follows:

  1. Braze 5 in. (127 mm) liquid tube to the indoor coil.
  2. Wrap filter drier with damp cloth.
  3. Braze filter drier to above 5 in. (127 mm) liquid tube. Flow arrow must point towards indoor coil.
  4. Connect and braze liquid refrigerant tube to the filter drier.
Figure 3 Liquid Line Filter DrierTEMPSTAR CSA6 Split System Air Conditioner 03 Refrigerant Tubing Connection Outdoor Connect vapor tube to fitting on outdoor unit vapor service valves (see Table 2.) Connect and braze the 3/8” coupling (provided with the filter drier) to the liquid service valve and connect and braze the liquid tubing to the other end of this coupling. Use refrigerant grade tubing.

Sweat Connection

CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Service valves must be wrapped in a heat−sinking material such as a wet cloth. Service valves are closed from factory and ready for brazing. After wrapping service valve with a wet cloth, braze sweat connections using industry accepted methods and materials. Consult local code requirements. Refrigerant tubing and indoor coil are now ready for leak testing. This check should include all field and factory joints.

Evacuate Refrigerant Tubing and Indoor Coil

CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Never use the system compressor as a vacuum pump. Refrigerant tubes and indoor coil should be evacuated using the recommended deep vacuum method of 500 microns. An alternate triple evacuation method may be used. See triple evacuation method in Service Manual. IMPORTANT: Always break a vacuum with dry nitrogen. Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum of 500 microns and a vacuum gage capable of accurately measuring this vacuum depth. The deep vacuum method is the most positive way of assuring a system is free of air and liquid water. (See Fig. 4) Figure 4 Deep Vacuum Graph TEMPSTAR CSA6 Split System Air Conditioner 04 Final Tubing Check IMPORTANT: Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment. Ensure tubes are not rubbing against each other or any sheet metal. Pay close attention to feeder tubes, making sure wire ties on feeder tubes are secure and tight.

Make Electrical Connections

WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Do not supply power to unit with compressor terminal box cover removed. Be sure field wiring complies with local and national fire, safety, and electrical codes, and voltage to system is within limits shown on unit rating plate. Contact local power company for correction of improper voltage. See unit rating plate for recommended circuit protection device. NOTE: Operation of unit on improper line voltage constitutes abuse and could affect unit reliability. See unit rating plate. Do not install unit in system where voltage may fluctuate above or below permissible limits. NOTE: Use copper wire only between disconnect switch and unit. NOTE: Install branch circuit disconnect of adequate size per NEC to handle unit starting current. Locate disconnect within sight from and readily accessible from unit, per Section 440−14 of NEC. Route Ground and Power Wires Remove access panel to gain access to unit wiring. Extend wires from disconnect through power wiring hole provided and into unit control box. WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes. Connect Ground and Power Wires Connect ground wire to ground connection in control box for safety. Connect power wiring to contactor as shown in Fig. 5. Figure 5 Line Power ConnectionsTEMPSTAR CSA6 Split System Air Conditioner 05 Connect Control Wiring Route 24−v control wires through control wiring grommet and connect leads to control wiring. (See Fig. 10 & Fig. 11) Use No. 18 AWG color−coded, insulated (35C minimum) wire. If thermostat is located more than 100 ft. (30.48 m) from unit, as measured along the control voltage wires, use No. 16 AWG color−coded, insulated wire to avoid excessive voltage drop. All wiring must be NEC Class 1 and must be separated from incoming power leads. Use furnace transformer, fan coil transformer, or accessory transformer for control power, 24−v/40−va minimum. NOTE: Use of available 24−v accessories may exceed the minimum 40−va power requirement. Determine total transformer load and increase the transformer capacity or split the load with an accessory transformer as required. Final Wiring Check IMPORTANT: Check factory wiring and field wire connections to ensure terminations are secured properly. Check wire routing to ensure wires are not in contact with tubing, sheet metal, etc.

Compressor Crankcase Heater

When equipped with a crankcase heater, furnish power to heater a minimum of 24 hr before starting unit. To furnish power to heater only, set thermostat to OFF and close electrical disconnect to outdoor unit. A crankcase heater is required for low−ambient cooling or if refrigerant tubing is longer than 80 ft. (24.38 m). Refer to the Long Line Applications Guideline − Residential Split−System Air Conditioners and Heat Pumps Using R−410A Refrigerant.

Install Electrical Accessories

Refer to the individual instructions packaged with kits or accessories when installing. Check OAT Thermistor and OCT Thermistor Attachments Outdoor Air Temperature (OAT) Thermistor is factory installed by inserting the nibs on either sides of the thermistor body through a keyhole in the bottom shelf of the control box and locking it in place by turning it 90 degrees, such that the spherical end of a nib faces the front of the control box. Check to make sure the OAT is locked in place. See Fig. 6. Figure 6 Outdoor Air Thermistor (OAT) AttachmentTEMPSTAR CSA6 Split System Air Conditioner 06 The Outdoor Coil Temperature (OCT) Thermistor is factory installed on the liquid tube between the coil assembly and the liquid service valve. See Fig. 7. Check to make sure the thermistor is securely attached on the liquid tube with the clip as shown in Fig. 7. Figure 7 Outdoor Coil Thermistor (OAT) Attachment TEMPSTAR CSA6 Split System Air Conditioner 07 Start−Up CAUTION UNIT OPERATION AND SAFETY HAZARD Failure to follow this caution may result in minor personal injury, equipment damage or improper operation. To prevent compressor damage or personal injury, observe the following:

CAUTION PERSONAL INJURY HAZARD Failure to follow this caution may result in personal injury. Wear safety glasses, protective clothing, and gloves when handling refrigerant and observe the following:
CAUTION
ENVIRONMENTAL HAZARD
Failure to follow this caution may result in environmental damage.
Federal regulations require that you do not vent refrigerant to the atmosphere. Recover during system repair or final unit disposal.
Follow these steps to properly start up the system:
  1. After system is evacuated, fully open liquid and vapor service valves.
  2. Unit is shipped with valve stem(s) front seated (closed) and caps installed. Replace stem caps after system is opened to refrigerant flow. Replace caps finger−tight and tighten with wrench an additional 1/12 turn
  3. Close electrical disconnects to energize system.
  4. Set room thermostat at desired temperature. Be sure set point is below indoor ambient temperature.
  5. Set room thermostat to COOL and fan control to ON or AUTO mode, as desired. Operate unit for 15 minutes. Check system refrigerant charge.

Check Charge

Factory charge amount and desired sub cooling are shown on unit rating plate. Charging method is shown on information plate inside unit. To properly check or adjust charge, conditions must be favorable for sub cooling charging. Favorable conditions exist when the outdoor temperature is between 70 F and 100 F (21.11 C and 37.78 C), and the indoor temperature is between 70 F and 80 F (21.11 C and 26.67 C). Follow the procedure below: Unit is factory charged for 15ft (4.57 m) of linseed. Adjust charge by adding or removing 0.6 oz/ft of 3/8 liquid line above or below 15ft (4.57 m) respectively. For standard refrigerant line lengths (80 ft/24.38 m or less), allow system to operate in cooling mode at least 15 minutes. When operating with the Observer Wall Control in communicating mode, make sure that indoor airflow is set to “efficiency” during charging. If conditions are favorable, check system charge by sub cooling method. If any adjustment is necessary, adjust charge slowly and allow system to operate for 15 minutes to stabilize before declaring a properly charged system If the indoor temperature is above 80 F (26.67 C), and the outdoor temperature is in the favorable range, adjust system charge by weight based on line length and allow the indoor temperature to drop to 80 F (26.67 C) before attempting to check system charge by subcooling method as described above. If the indoor temperature is below 70 F (21.11 C), or the outdoor temperature is not in the favorable range, adjust charge for line set length above or below 15ft (4.57 m) only. Charge level should then be appropriate for the system to achieve rated capacity. The charge level could then be checked at another time when the both indoor and outdoor temperatures are in a more favorable range. NOTE: If line length is beyond 80 ft (24.38 m) or greater than 20 ft (6.10 m) vertical separation, See Long Line Applications Guideline for special charging requirements.

Major Components

Control Board

The AC control board controls the following functions:

Field Connections When using communicating control, 4 field wires are required to be connected to the factory wires already wired to the DX+DX−C R terminal (see Fig. 10). Unit as provided by manufacturer is set up for communicating control. When used with a standard non−communicating thermostat, it is recommended to use 3 thermostat control wires to be connected to R, Y and C. When using 3 wires, all diagnostic and time delay features are enabled (See Fig. 11 ). Disconnect factory provided wires from DX+, DX−, C & R terminals. Using factory provided wires, connect to R, C, and Y on the control board for 3 wire thermostat control. Connect field 24V wires to factory provided wires now connected to R, C, and Y and cap both sides or remove unused factory provided wires. When only 2 thermostat control wires are available, units will function, but some control features are lost. (See Fig. 12). With only 2 wires connected, the circuit board will be powered down whenever there is no call for cooling, and the following will result: Disconnect factory provided wires from DX+, DX−, C and R terminals. Using factory provided wires, connect to C and Y on the control board for 2 wire thermostat control. A field installed jumper wire is also required between R and Y (See Fig. 12). Connect field 24V wires to factory provided wires now connected to C and Y and cap both sides or remove unused factory provided wires. Compressor Internal Relief The compressor is protected by an Internal Pressure Relief (IPR) which relieves discharge gas into the compressor shell when differential between suction and discharge pressure exceeds 550−625 psi. The compressor is also protected by an internal overload attached to motor windings.

GENERAL SEQUENCE OF OPERATION STANDARD THERMOSTAT

Turn on power to indoor and outdoor units. Transformer is energized. On a call for cooling, thermostat makes circuits R−Y and R−G. Circuit R−Y energizes contactor, starting outdoor fan motor and compressor circuit. R−G energizes indoor unit blower relay, starting indoor blower motor on high speed. NOTE: To achieve the rated system performance, the indoor unit or the thermostat must be equipped with a time delay relay circuit. When term o stat is satisfied, its contacts open, de−energizing contactor and blower relay. Compressor and motors stop. If indoor unit is equipped with a time−delay relay circuit, the indoor blower will run an additional 90 sec to increase system efficiency CONTROL FUNCTIONS AND SEQUENCE OF OPERATION The outdoor unit control system has special functions. The following is an overview of the control functions.

SEQUENCE OF OPERATION

Cooling Operation

This product utilizes either a standard indoor thermostat or Observer Communicating Wall Control. With a call for cooling, the outdoor fan and compressor are energized. When the cooling demand is satisfied, the compressor and fan will shut off. NOTE: The outdoor fan motor will continue to operate for one minute after compressor shuts off, when the outdoor ambient is greater than or equal to 100 F (37.78 C).

Communication and Status Function Lights

Green Communications (COMM) Light (Communicating Control only):

A green LED (COMM light) on the outdoor board indicates successful communication with the other system products. The green LED will remain OFF until communications is established. Once a valid command is received, the green received within 2 minutes, the LED will be turned OFF until the next valid communication.

Amber Status Light

An amber colored STATUS light is used to display the operation mode and fault codes as specified in the troubleshooting section. See Table 3 for codes and definitions. NOTE: Only one fault code will be displayed on the outdoor unit control board (the most recent, with the highest priority). Crankcase Heater Operation The crankcase heater (when applicable) is energized during the off cycle below 65 F (37.78 C) Outdoor Fan motor Operation The outdoor unit control energizes outdoor fan any time the compressor is operating. The outdoor fan remains energized for 15 minutes if a pressure switch or compressor thermal protector should open. Outdoor fan motor will continue to operate for one minute after the compressor shuts off when the outdoor ambient is greater than or equal to 100 F (37.78 C). Time Delays The unit time delays include:

Utility Interface With Non−Communicating Thermostats Utility curtailment will only work when the unit is operating with a non−communicating thermostat. When the utility curtailment interface is applied with a non−communicating thermostat, the utility relay should be wired in series with the Y input.

Low Ambient Cooling

When this unit is required to operate below 55 F (12.78 C) to a minimum of 0 F (−17.78 C) outdoor temperature, provisions must be made for low ambient operation. Low ambient applications require the installation of accessory kits:

Support feet are recommended for low ambient cooling. See Product Specification sheet for kit part numbers on appropriate unit size and series unit. For low am bi entcoolingwith the Observer Communicating Wall Control the cooling lockout must be set to “Off” in the Wall Control setup.

Liquid Line Solenoid

When operating in communicating mode the standard thermostat terminals will not function. A terminal on the non−communicating thermostat bus labeled “LS” on the AC control board is provided for wiring liquid line solenoids when LED will turn ON continuously.  If no communication   in communicating mode. For operation in communicating mode wire solenoid valve kit NASA401LS across LS and C terminals . For operation in non−communicating mode wire solenoid valve kit NASA401LS across C and Y terminals.

TROUBLESHOOTING

SYSTEMS COMMUNICATION FAILURE

If communication between outdoor unit, control board, and indoor wall control has failed, the control will flash the appropriate fault code. (See table 3) Check the wiring to the wall control, indoor and outdoor units. PRESSURE SWITCH PROTECTION The outdoor unit is equipped with high− and low−pressure switches. If the control senses the opening of a high or low−pressure switch, it will de−energize the compressor contactor, keep the outdoor fan operating for 15 minutes and display the appropriate fault code. (See table 3) After a 15 minute delay, if there is still a call for cooling, and the LPS or HPS is reset, the compressor contactor is energized. If the LPS or HPS has not closed after a 15 minute delay, the outdoor fan is turned off. If the open switch closes anytime after the 15−minute delay, then the unit will resume operation with a call for cooling. If the LPS or HPS trips for five consecutive cycles, then unit operation is locked out for 4 hours and the appropriate fault code (See table 3) is displayed. In the event of a high−pressure switch trip or high−pressure lockout, check the refrigerant charge, outdoor fan operation and outdoor coil for airflow restrictions. In the event of a low−pressure switch trip or low−pressure lockout, check the refrigerant charge and indoor airflow. CONTROL FAULT If the outdoor unit control board has failed, the control will flash the appropriate fault code. (See table 3) The control board should be replaced. 24V BROWN OUT PROTECTION If the control voltage is less than 15.5volts for at least 4 seconds, the compressor contactor and fan relay are de−energized. Compressor and fan operation are not allowed until control voltage is a minimum of 17.5volts. The control will flash the appropriate fault code. (See table 3) Verify the control voltage is in the allowable range of 18−30volts. COMPRESSOR VOLTAGE SENSING The input terminals labeled VR and VS on the control board (see Fig. 9) are used to detect compressor voltage status, and alert the user of potential problems. The control continuously monitors the high voltage on the run capacitor of the compressor motor. Voltage should be present any time the compressor contactor is energized, and voltage should not be present when the contactor is de−energized. COMPRESSOR THERMAL CUTOUT OR LOSS OF 230V POWER If the control senses the compressor voltage after start−up, and is then absent for 10 consecutive seconds while cooling demand exists, it will de−energize the compressor contactor, keep the outdoor fan operating for 15 minutes (if 230v power present) and display the appropriate fault code. (See table 3) Possible causes are compressor internal overload trip or loss of high voltage (230V) to compressor without loss of control voltage. After a 15 minute delay, if there is still a call for cooling, the compressor contactor is energized. If the thermal protector has not re−set, the outdoor fan is turned off. If the call for cooling continues, the control will energize the compressor contactor every 15 minutes. If the thermal protector closes, (at the next 15 minute interval check), the unit will resume operation. If the thermal cutout trips for three consecutive cycles, then unit operation is locked out for 4 hours and the appropriate fault code (See Table 3) is displayed.

CONTACTOR SHORTED DETECTION

If there is compressor voltage sensed when there is no demand for compressor operation, the contactor may be stuck closed. The control will flash the appropriate fault code. Check the contactor and control box wiring.

NO 230V AT COMPRESSOR

I f the com p re s s o r voltage is not sensed when the compressor should be starting, the contactor may be stuck open or the unit disconnect or circuit breaker may be open. The control will flash the appropriate fault code. Check the contactor, unit disconnect or circuit breaker and control box wiring.

TEMPERATURE THERMISTORS

Thermistors are electronic devices which sense temperature. As the temperature increases, the resistance decreases. Thermistors are used to sense outdoor air (OAT) and coil temperature (OCT). If the outdoor air or coil thermistor should fail, the control will flash the appropriate fault code. (See table 3). IMPORTANT: The outdoor air thermistor and coil thermistor are factory mounted in the correct locations. Do not re−locate thermistor sensors. THERMISTOR SENSOR COMPARISON The control continuously monitors and compares the outdoor air temperature sensor and outdoor coil temperature sensor to ensure proper operating conditions. The comparison is, if the outdoor air sensor indicates ³10 F (³ −12.22 C) warmer than the coil sensor (or) the outdoor air sensor indicates ³20 F (³ −6.67 C) cooler than the coil sensor, the sensors are out of range. If the sensors are out of range, the control will flash the appropriate fault code. (See Table 3). FAILED THERMISTOR DEFAULT OPERATION Factory defaults have been provided in the event of failure of outdoor air thermistor and/or coil thermistor. Thermistor Curve: The resistance vs. temperature chart shown in Figure 8 enables the technician to check the outdoor air and outdoor coil thermistors for proper resistance. Unplug the thermistor assembly from the circuit board and measure resistance across each thermistor. For example, if the outdoor temperature is 60 F (15.56 C), the resistance reading across the outdoor air thermistor should be around 16,000 Ohms.

STATUS CODES

Table 3 shows the status codes flashed by the amber status light. Most system problems can be diagnosed by reading the status code as flashed by the amber status light on the control board. The codes are flashed by a series of short and long flashes of the status light. The short flashes indicate the first digit in the status code, followed by long flashes indicating the second digit of the error code. The short flash is 0.25 second ON and the long flash is 1.0 second ON. Time between flashes is 0.25 second. Time between short flash and first long flash is 1.0 second. Time between code repeating is 2.5 seconds with LED OFF. Count the number of short and long flashes to determine the appropriate flash code. Table 3 gives possible causes and actions related to each error Example: 3 short flashes followed by 2 long flashes indicates a 32 code. Table 3 shows this to be low pressure switch open. Table 3 − Status Codes

OPERATION FAULT AMBER LED FLASH CODE Possible Cause and Action
Standby – no call for unit operation None On solid, no flash Normal operation − with communicating Control
Standby – no call for unit operation None Off Normal operation − No call for cooling with 2−wire connection or indoor unit not pow- ered.
Cooling Operation None 1, pause Normal operation
System Communications Failure 16 Communication with wall control lost. Check wiring to wall control, indoor and outdoor units
High Pressure Switch Open 31 High pressure switch trip. Check refrigerant charge, outdoor fan operation and coils for airflow restrictions.
Low Pressure Switch Open 32 Low pressure switch trip. Check refrigerant charge and indoor air flow
Control Fault 45 Outdoor unit control board has failed. Control board needs to be replaced.
Brown Out (24 v) 46 The control voltage is less than 15.5v for at least 4 seconds. Compressor and fan operation not allowed until control voltage is a minimum of 17.5v. Verify control volt- age.
Outdoor Air Temp Sensor Fault 53 Outdoor air sensor not reading or out of range. Ohm out sensor and check wiring
Outdoor Coil Sensor Fault 55 Coil sensor not reading or out of range. Ohm out sensor and check wiring
Thermistors out of range 56 Improper relationship between coil sensor and outdoor air sensor. Ohm out sensors and check wiring.
Thermal Cutout 72 Compressor voltage sensed after start−up, then absent for 10 consecutive seconds while cooling demand exists. Possible causes are internal compressor overload trip or loss of high voltage to compressor without loss of control voltage. The control will continue fan operation and wait 15 minutes to attempt a restart. Fault will clear when restart is successful, or low voltage power is cycled.
Contactor Shorted  73 Compressor voltage sensed when no demand for compressor operation exists. Con- tactor may be stuck closed or there is a wiring error.
No 230V at Compressor 74 Compressor voltage not sensed when compressor should be starting. Disconnect may be open or contactor may be stuck open or there is a wiring error.
Thermal Lockout 82 Thermal cutout occurs in three consecutive cycles. Unit operation locked out for 4 hours or until 24v power recycled.
Low Pressure Lockout 83 Low pressure switch trip has occurred during 3 consecutive cycles. Unit operation locked out for 4 hours or until 24v power recycled.
High Pressure Lockout 84 High pressure switch trip has occurred during 3 consecutive cycles. Unit operation locked out for 4 hours or until 24v power recycled.
Figure 8 Resistance vs Temperature ChartTEMPSTAR CSA6 Split System Air Conditioner 08 Figure 9 Single Stage Control Board TEMPSTAR CSA6 Split System Air Conditioner 09 Figure 10 Observer Communicating Wall Control Four−Wire Connection Wiring Diagrams (See Thermostat Installation Instructions for specific unit combinations)TEMPSTAR CSA6 Split System Air Conditioner 10 Figure 11 Non−Communicating Standard Thermostat 3−Wire 24V Circuit Connections (See Thermostat Installation Instructions for Specific Unit combinations)TEMPSTAR CSA6 Split System Air Conditioner 11 CAUTION ELECTRICAL OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation. A minimum of three wire thermostat wiring is required for the system to operate. Figure 12 Non−Communicating Standard Thermostat 2−Wire 24V Circuit ConnectionsTEMPSTAR CSA6 Split System Air Conditioner 12 NOTE: Wiring must conform to NEC or local codes. Figure 13 Non−Communicating Indoor with Observer Communicating Wall Control TEMPSTAR CSA6 Split System Air Conditioner 13 NOTE: This installation requires the daughter board accessory, NAXA00101DB. NOTE: This installation does not allow for communicating feature functionality. R−410A QUICK REFERENCE GUIDE

Documents / Resources

TEMPSTAR CSA6 Split System Air Conditioner [pdf] Instruction Manual
CSA6, HSA6, TSA6, CSA6 Split System Air Conditioner, CSA6, Split System Air Conditioner, Air Conditioner, Conditioner

References

Documents - tempstar – CONDITIONER,CSA6,HSA6,TSA6
[pdf] User Manual Instructions Label
Download Manual 440 KB Tempstar CSA6 Installation Instructions tempstar csa6 installation instructions manual dl2 manualsrepo manuals url aHR0cHM6Ly9saW5rLWNkbi5tYW51YWxzcmVwby5jb20vZmlsZS8 dG9rZW49ZVk4dUJBSHc4Nmk5UjdOWjBndk5ZU0ZPR0gzNkcyVGhERnVCOWhLQXk3ZkxtSUtOZi9aeWh6OGRQL25zeE9NV2ZUVHdQdHVZWVEwWk91Zzh3YkRrLzVIY1VmNjlQOUlYL1RiekFXUDZ4RGNKd2daWjdndExpR3F1S0FJZWxML20 file name |||
INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner CSA6, HSA6, TSA6 These instructions m ... -Communicating Standard Thermostat 2-Wire 24V Circuit Connections TPPICAL FURNACE OR FAN COIL AIR CONDITIONER 24VAC HOT R R R 24VAC COM C C C HEAT STAGE 1 W/W1 W HEAT STAGE 2 Y/Y2 Y Y ...
lang:en score:62 filesize: 500.96 K page_count: 14 document date: 2022-07-09
[pdf] User Manual Instructions Label
Provided by ManualsAndMore Download User Manual Tempstar CSA6 Installation Instructions manualsandmore |||
INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner CSA6, HSA6, TSA6 These instructions m ... -Communicating Standard Thermostat 2-Wire 24V Circuit Connections TPPICAL FURNACE OR FAN COIL AIR CONDITIONER 24VAC HOT R R R 24VAC COM C C C HEAT STAGE 1 W/W1 W HEAT STAGE 2 Y/Y2 Y Y ...
lang:en score:57 filesize: 487.26 K page_count: 14 document date: 2019-07-23
[pdf] User Manual Instructions Label
Provided by ManualsAndMore Download User Manual Tempstar N4A3 Installation Instructions manualsandmore |||
INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner N4A3, C4A3, H4A3, T4A3, NXA6, CXA6, HX ... 0A Split System Air Conditioner Figure 11 Typical Thermostat Connections THERMOSTAT FURNACE AIR CONDITIONER 24 VAC HOT R R 24 VAC COM C C HEAT STAGE 1 W/W1 W C COOL STAGE 1 Y/Y2 Y INDO...
lang:en score:36 filesize: 422.19 K page_count: 18 document date: 2019-07-23
[pdf] User Manual Instructions Accessories
44001105008 woodl Tempstar Furnace Manual Pdf INSTALLATION INSTRUCTIONS 9UHX questargas ForEmployees qgcOperationsTraining Furnaces |||
90 SINGLE STAGE GAS FURNACE DIRECT OR NON- DIRECT VENT Category IV Furnace *9UHX Upflow/Horizontal ... r inlet and clothes dryer vent. Terminate the combustion air intake as far as possible from any air conditioner, heat pump, swimming pool, swimming pool pumping, chlorinator or filtration unit. 1. In...
lang:en score:36 filesize: 2.99 M page_count: 53 document date: 2017-04-26
[pdf] Warranty
Tempstar® Split System Air Conditioners 42122540503 TS shareddocs hvac docs 1011 Public 06 |||
Tempstar Split System Air Conditioners SmartComfort Series TSA5/TSA6/TCA7/TVA9 Heating and Cooling ... de in surpassing your expectations and delivering quality you can feel. WHAT IS A SPLIT SYSTEM AIR CONDITIONER Tempstar split system air conditioners are designed for the best durability and comfort...
lang:en score:34 filesize: 2.03 M page_count: 4 document date: 2016-05-13
[pdf] Warranty
R4A5 Warranty v2 bac0760 ACiQ 1 5 Ton 14 SEER Air Conditioner Condenser R4A418GK HVACDirect hvacdirect media |||
International Comfort Products Limited Warranty Certi cate Covered Products: Split System Air Conditioner and Heat Pu mp Products Smaller than 65,000-Btuh Cooling Capacity See Chart Below FOR WARRANTY SERVICE OR REPAIR: Contact the installer or an International Comfort Products dealer. You may ...
lang:en score:34 filesize: 1.32 M page_count: 2 document date: 2023-08-28
[pdf] Warranty
Tempstar® Split System Air Conditioners T4A318GKF CUT pimmedia winsupplyinc pim 022020 |||
Tempstar Split System Air Conditioners SmartComfort Series T4A3 Heating and Cooling Products BUI ... e in addition to a 10-year parts and compressor limited warranty.* YEAR WHAT IS A SPLIT SYSTEM AIR CONDITIONER Tempstar split system air conditioners are designed for the best in durability and comf...
lang:en score:32 filesize: 1.57 M page_count: 4 document date: 2016-07-25
[pdf] Warranty
AC HP 40106430019 bac0760 shareddocs hvac docs 1011 Public 06
International Comfort Products Limited Warranty Certificate Covered Products: Split System Air Conditioner and Heat Pump Products Smaller than 65,000-Btuh Cooling Capacity See Chart Below FOR WARRANTY SERVICE OR REPAIR: Contact the installer or an International Comfort Products dealer. You may be...
lang:en score:31 filesize: 209.81 K page_count: 2 document date: 2021-03-09
[pdf] Warranty
40106430019 bac0760 icp n4h4 war resource bakerdist is content Watscocom Gemaire
International Comfort Products Limited Warranty Certificate Covered Products: Split System Air Conditioner and Heat Pump Products Smaller than 65,000-Btuh Cooling Capacity See Chart Below FOR WARRANTY SERVICE OR REPAIR: Contact the installer or an International Comfort Products dealer. You may be...
lang:en score:31 filesize: 214.19 K page_count: 2 document date: 2020-02-26
[pdf] Warranty
AC HP 40106430020 bact04l shareddocs hvac docs 1011 Public 0C |||
International Comfort Products Limited Warranty Certificate Covered Products: Split System Air Conditioner and Heat Pump Products Smaller than 65,000-Btuh Cooling Capacity See Chart Below FOR WARRANTY SERVICE OR REPAIR: Contact the installer or an International Comfort Products dealer. You may be...
lang:en score:31 filesize: 210.68 K page_count: 2 document date: 2021-08-12
[pdf] Borchure
17 ICP 0017 M1mp FR ITS 4pg TSA5 TSA6 TCA7 TVA9 TSH4 TSH5 TCH6 TVH8 indd brochure tempstar refrigerationeverest 2020 03 |||
Systme centrale bibloc TempstarMD Climatiseurs et pompes chaleur Srie SmartComfortMD TSA5/TSA6/TCA7/TVA9 TSH4/TSH5/TCH6/TVH8 Produits de chauffage et de climatisation Une Qualit IncontournableMC CONSTRUCTION ROBUSTE Lorsque vous choisissez un appareil de chauffage et de climatisation TempstarMD...
lang:fr score:31 filesize: 2.2 M page_count: 4 document date: 2018-03-20
[pdf] Warranty Catalog
Tempstar® Variable Speed Inverter Air Conditioners First Tempstar ® Heating and Cooling Products 15 ICP 0035 M1rb ITS 4pg AC HVA9 indd 2 9 29 7 53 PM  34065 TVA924GKA Catalog firstsupply UserFiles Documents inRiver Original |||
Tempstar Variable-Speed Inverter Air Conditioners SmartComfort Deluxe 19 with SmartSenseTM Technolo ... egistration 15-ICP-0035 M1rb ITS 4pg AC HVA9.indd 3 9/29/15 7:53 PM SMARTCOMFORT DELUXE 19 AIR CONDITIONER WITH SMARTSENSETM TECHNOLOGY The SmartComfort Deluxe 19 Air Conditioner with SmartSenseT...
lang:en score:30 filesize: 539.8 K page_count: 4 document date: 2015-09-30
[pdf] Warranty
Tempstar® Variable Speed Inverter Air Conditioners Carrier TVA9 Ion™ 19 Conditioner with SmartSense™ Technology Up to SEER cooling efficiency speed compressor for quiet and efficient operation 42122540601 TS shareddocs hvac docs 1011 Public 0E |||
TempstarVariable-Speed Inverter Air Conditioners IonTM 19 with SmartSenseTM Technology TVA9 Heatin ... entTM limited warranty* 10-year parts limited warranty upon timely registration ** IONTM 19 AIR CONDITIONER WITH SMARTSENSETM TECHNOLOGY The Ion 19 Air Conditioner with SmartSense Technology offer...
lang:en score:29 filesize: 791.66 K page_count: 4 document date: 2020-04-08
[pdf] User Manual Installation Guide Specifications Warranty
TEMPSTAR N4A536GKC 01 MANUAL Manual Hub drive google file d 1fVYLAE2I5j0P3v88qyPieQdV2vGtM4lq preview |||
ENTALLY SOUND RE FRIGERANT N4A5 Performance Series Product Specifications ENVIRONM EFFICIENT 14 SEER/11.7-12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1-phase, 60 Hz 208/230, 460 575 Volt, 3-phase, 60 Hz REFRIGERATION CIRC...
lang:en score:29 filesize: 1.5 M page_count: 12 document date: 2023-10-27
[pdf] User Manual Installation Guide Specifications Warranty
TEMPSTAR N4A542GKC 01 MANUAL Manual Hub drive google file d 1LPpc kfBdyyrtpYlRFJ6JRttScyxBr0t preview |||
ENTALLY SOUND RE FRIGERANT N4A5 Performance Series Product Specifications ENVIRONM EFFICIENT 14 SEER/11.7-12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1-phase, 60 Hz 208/230, 460 575 Volt, 3-phase, 60 Hz REFRIGERATION CIRC...
lang:en score:29 filesize: 1.5 M page_count: 12 document date: 2023-10-27
[pdf] User Manual Installation Guide Specifications Warranty
TEMPSTAR N4A560GKC 01 MANUAL Manual Hub drive google file d 1pmdl3tt4M9ulVsLME 8MFXzULCaZozv7 preview |||
ENTALLY SOUND RE FRIGERANT N4A5 Performance Series Product Specifications ENVIRONM EFFICIENT 14 SEER/11.7-12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1-phase, 60 Hz 208/230, 460 575 Volt, 3-phase, 60 Hz REFRIGERATION CIRC...
lang:en score:29 filesize: 1.5 M page_count: 12 document date: 2023-10-27
[pdf] User Manual Installation Guide Specifications Warranty
TEMPSTAR N4A524GKC 01 MANUAL Manual Hub drive google file d 1RNFqIPkxQ1v6tzMS nSTb0KyQeV vdd5 preview |||
ENTALLY SOUND RE FRIGERANT N4A5 Performance Series Product Specifications ENVIRONM EFFICIENT 14 SEER/11.7-12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1-phase, 60 Hz 208/230, 460 575 Volt, 3-phase, 60 Hz REFRIGERATION CIRC...
lang:en score:29 filesize: 1.5 M page_count: 12 document date: 2023-10-27
[pdf]
air conditioners Carrier 30 dic 2021 — Choose Tempstar® heating and cooling equipment so you can enjoy comfort with confidence Our products deliver exceptional quality reliability energy  AC 003 TS 00 shareddocs hvac docs 1011 Public 05 |||
Performance Series AIR CON DITION E RS Heating and Cooling Products COOL INDOOR COMFORT Performance ... one more example of how Tempstar goes the extra mile for your satisfaction. WHAT MATTERS IN AN AIR CONDITIONER ENERGY SAVINGS SEER Seasonal Energy Efficiency Ratio measures the cooling efficiency ...
lang:en score:29 filesize: 681.58 K page_count: 4 document date: 2021-12-13
[pdf] Guide Label
2023 Compliance Sheet Tempstar Corken Steel Products corkensteel 2022 11 |||
2023 SPLIT SYSTEM COMPLIANCE Heating and Cooling Products F O R E X I S T I N G I N V E N T O R Y New DOE Minimum Efficiency Requirements Beginning January 1, 2023, the DOE is increasing the minimum efficiencies for central air conditioners and heat pumps. For air conditioners in the North, the m...
lang:en score:28 filesize: 775.72 K page_count: 2 document date: 2022-09-12
[pdf] Warranty
Tempstar® Residential Warranties at a Glance Tempstar Heating and Cooling Products backs the heat exchanger with longer limited warranty periods up to lifetime available on select models the  40122063003 TS shareddocs hvac docs 1011 Public 09 |||
Tempstar Residential Warranties at a Glance * ** MAXIMUM STRENGTH WARRANTIES FOR HOMEOWNERS Every ... ting and cooling system. PARTS LIMITED WARRANTY Tempstar gas and oil furnaces and R-410A-based air conditioners, heat pumps, fan coils, geothermal, ductless systems and small package products carry a...
lang:en score:28 filesize: 1.17 M page_count: 4 document date: 2019-07-16
[pdf] User Manual Parts List Diagram Label
ICP PACKAGE AIR CONDITIONER PAF APFM Series MANUAL 2 to 5 TON 2001 Tempstar at Inspectapedia Manuals Parts Lists Wiring Diagrams Packaged AC Manual inspectapedia heat |||
CLICK ANYWHERE on THIS PAGE to RETURN to ICP INTERNATIONAL COMFORT SYSTEMS HVAC at InspectApedia.com SINGLE PACKAGE AIR CONDITIONERS PAF APFM Series -- 2 to 5 TON Printed in U.S.A. 519 01 1102 00 10--25--01 Safety Labeling and Signal Words Danger, Warning and Caution The signal words DANGER, ...
lang:en score:27 filesize: 1.33 M page_count: 14 document date: 2002-09-04
[pdf] Warranty
Tempstar® Split System Heat Pumps WHAT IS A SPLIT SYSTEM HEAT PUMP Tempstar split system heat pumps are designed for the best durability and comfort Properly matched combinations of an 42822540504 TS shareddocs hvac docs 1011 Public 07 |||
Tempstar Split System Heat Pumps QuietComfort Series TSH4/TSH5/TSH6/TCH6/TVH8 Heating and Cooling ... WHAT DO THEY MEAN Seasonal Energy Efficiency Ratio SEER --M easures the cooling efficiency of air conditioners and heat pumps during an average cooling season. The higher the SEER, the greater the e...
lang:en score:27 filesize: 1008.79 K page_count: 4 document date: 2017-09-18
[pdf] Specifications Warranty Catalog
TEMPSTAR® RESIDENTIAL HEATING COOLING Tempstar ® Residential Photos and Specifications for the complete product line including air conditioners heat pumps oil furnaces small packaged products fan coils modular  Plus if you need a hard copy of catalog can always version print it yourself tempstar fxm4x6000al article 1395692890188 en cl resource bakerdist is content Watscocom Gemaire |||
TEMPSTAR RESIDENTIAL HEATING COOLING PRODUCTS PRODUCT AT-A-GLANCE FOLDOUT WARRANTY LIMITED No H ... wading through every brand in the industry. Try it today Quality you can feel. RESIDENTIAL AIR CONDITIONERS ALL R-410A REFRIGERANT Deluxe 19/17 TVA9 - Inverter VariableSpeed compressor -Commun...
lang:en score:27 filesize: 1.57 M page_count: 8 document date: 2018-03-13
[pdf] User Manual Parts List Diagram Label
42104550300 Tempstar C4A4 H4A4 T4A4 Technical Support Manual woodl ICP International Comfort Products TEMPSTAR C4HF Split System Air Conditioner TECHNICAL MANUAL HVAC Age Manuals Parts Lists Wiring Diagrams Downloads Contact Info inspectapedia heat |||
CLICK ANYWHERE on THIS PAGE to RETURN to TEMPSTAR HVAC at InspectApedia.com TECHNICAL SUPPORT MANUAL Split System Air Conditioner C,H,T 4A4 Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard...
lang:en score:27 filesize: 283.19 K page_count: 18 document date: 2010-03-02
[pdf] Warranty Catalog
TEMPSTAR® RESIDENTIAL HEATING COOLING The No Hassle Replacement limited warranty offers a one time new equivalent Maximum Strength Warranties include Tempstar® gas and oil furnaces   47000 Tempstar EAA4X18L14A Catalog firstsupply UserFiles Documents inRiver Original |||
TEMPSTAR RESIDENTIAL HEATING COOLING PRODUCTS PRODUCT AT-A-GLANCE FOLDOUT WARRANTY LIMITED No H ... wading through every brand in the industry. Try it today Quality you can feel. RESIDENTIAL AIR CONDITIONERS ALL R-410A REFRIGERANT SmartComfortTM Deluxe 19/17 TVA9 - Inverter Variable- Speed c...
lang:en score:26 filesize: 1.71 M page_count: 8 document date: 2017-02-01
[pdf] User Manual Owner's Manual Accessories
51902170207 TEMPSTAR PAD4 WPA4 PACKAGED AIR CONDITIONER OWNERS MANUAL bac0075 Tempstar at Inspectapedia Packaged AC Manual Turn off the electrical power supply to unit Operating Your Unit The operation of your is controlled by indoor thermostat You simply adjust inspectapedia heat |||
CLICK ANYWHERE on THIS PAGE to RETURN to TEMPSTAR HVAC at InspectApedia.com PAD4, WPA4 14 SEER Single and Three Phase Single Packaged Air Conditioner System with R-410A Refrigerant 2-5 Nominal Tons Sizes 24-60 Owner s Information Manual Fig. 1 Unit PAD4 and WPA4 A09034 NOTE TO EQUIPMENT OWNER:...
lang:en score:26 filesize: 1.1 M page_count: 6 document date: 2020-08-11
[pdf] Frequently Asked Questions Guide
2023 TEMPSTAR Distributor Kit Are You Ready Corken Steel Products Tempstar corkensteel 2022 11 |||
2023 REGULATORY REQUIREMENTS PRODUCT OVERVIEW Contents 3 Introduction Letter 4 2023 Regulatory O ... ings 14.3 SEER2 7.5 HSPF2 13.4 SEER2 10.6 EER2 13.4 SEER2 6.7 HSPF2 2023 Regulatory Overview AIR CONDITIONER RATINGS The new 2023 minimum efficiency standards for air conditioners continue to follo...
lang:en score:25 filesize: 7.37 M page_count: 58 document date: 2022-11-15
[pdf] Installation Guide
AC HP 40106430020FR bact04l shareddocs hvac docs 1011 Public 0B |||
International Comfort Products Certificat de garantie limite Produits couverts : Systmes de thermo ... CH9, TCH9, 10 5 ou 10 5 CVH8, HVH8, TVH8, CVA9, HVA9, TVA9 CSH5, HSH5, TSH5, CSH6, HSH6, TSH6, CSA6, HSA6, TSA6, CXA6, HXA6, TXA6, CXH5, HXH5, TXH5 CSH4, HSH4, TSH4; CSA5, HSA5, TSA5 C4A3, H4A3, ...
lang:fr score:24 filesize: 227.32 K page_count: 2 document date: 2021-08-12
[pdf] Installation Guide
AC HP 40106430019FR bac0760 shareddocs hvac docs 1011 Public 06 |||
International Comfort Products Certificat de garantie limite Produits couverts : Systmes de thermo ... CH9, TCH9, 10 5 ou 10 5 CVH8, HVH8, TVH8, CVA9, HVA9, TVA9 CSH5, HSH5, TSH5, CSH6, HSH6, TSH6, CSA6, HSA6, TSA6, CXA6, HXA6, TXA6, CXH5, HXH5, TXH5 CSH4, HSH4, TSH4; CSA5, HSA5, TSA5 C4A3, H4A3, ...
lang:fr score:24 filesize: 227.58 K page_count: 2 document date: 2021-03-09
[pdf] Warranty
42122540504 TS shareddocs hvac docs 1011 Public 01 |||
Tempstar Split System Air Conditioners IonTM System TSA5/TSA6/TCA7/TVA9 Heating and Cooling Produc ... you the most in home comfort so you can enjoy comfort with confidence. WHAT IS A SPLIT SYSTEM AIR CONDITIONER Tempstar split system air conditioners are designed for durability and comfort. Properl...
lang:en score:24 filesize: 975.19 K page_count: 4 document date: 2020-04-08
[pdf] Warranty
untitled Air Conditioners And 13 14 15 SEER icpindexing toddsit Tempstar® Heat Pumps Tempstar and Scroll compressor for quiet efficient operation Post painted coil fins corrosion resistance 09tempst1482 AC HP documents 086641 |||
13/14/15 Air Conditioners And SEER Heat Pumps Tempstar Air Conditioners And Heat Pumps Tempstar pr ... fficiency and dependability. At a high SEER and HPSF the industry terms to rate efficiencythese air conditioners and heat pumps will make a big difference in lowering energy bills. So Tempstar lets yo...
lang:en score:24 filesize: 843.71 K page_count: 4 document date: 2010-02-02
[pdf] User Manual Owner's Manual
32802000102 fm TEMPSTAR DLFSHA DUCTLESS WALL SYSTEM OWNERS MANUAL cbs1525 Tempstar at InspectApedia Ductless Wall System Manual InspectAPedia NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation GENERAL The high wall fan coil unit provides quiet inspectapedia heat |||
DLFSHA OWNER S MANUAL High Wall Ductless System - Sizes 09 to 36 TABLE OF CONTENTS PAGE A NOTE AB ... tions and warnings, including labels shipped with or attached to unit before operating your new air conditioner. GENERAL The high wall fan coil unit provides quiet, maximum comfort. In addition to co...
lang:en score:23 filesize: 2.5 M page_count: 14 document date: 2018-12-05
[pdf] Frequently Asked Questions Guide
Distributor 2023 Regulatory Requirements Tempstar Corken Steel Products corkensteel 2022 11 |||
2023 REGULATORY REQUIREMENTS PRODUCT OVERVIEW Contents 3 Introduction Letter 4 2023 Regulatory O ... ings 14.3 SEER2 7.5 HSPF2 13.4 SEER2 10.6 EER2 13.4 SEER2 6.7 HSPF2 2023 Regulatory Overview AIR CONDITIONER RATINGS The new 2023 minimum efficiency standards for air conditioners continue to follo...
lang:en score:22 filesize: 5.22 M page_count: 44 document date: 2022-08-18
[pdf] User Manual Parts List Diagram Label
Cover ICP SPLIT SYSTEM AIR CONDITIONER C H T CA7 TECHNICAL MANUAL wades International Comfort Products at InspectApedia Manuals Parts Lists Wiring Diagrams CHT Technical Manual inspectapedia aircond |||
CLICK ANYWHERE on THIS PAGE to RETURN to ICP HVAC MANUALS INFORMATION AT InspectApedia.com TECHNICAL SUPPORT MANUAL Two Stage Split System Air Conditioner C,H,T CA7 Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used t...
lang:en score:22 filesize: 1.21 M page_count: 40 document date: 2012-03-26
[pdf]
42122550400 TS shareddocs hvac docs 1011 Public 08 |||
TempstarSplit System Air Conditioners Performance Series N4A3, NH4A4, N4A4, NXA4/N4A5, N4A7, NXA6/N4A6 Heating and Cooling Products WHAT SETS TEMPSTARAIR CONDITIONERS 1. Durable galvanized steel construction with baked-on paint finish built to weather the seasons. 2. Post-painted fin stock and ...
lang:en score:22 filesize: 808.25 K page_count: 4 document date: 2021-04-19
[pdf] User Manual Owner's Manual
untitled Manuals ICP TempStar and Heil Parts Split System Air Conditioning Owners Manual icptempstarparts mdocs file 42042 |||
HOME OWNER S INFORMATION Split System Air Conditioner THERMOSTAT Your air conditioner is controlled by the thermostat mounted on your wall. The thermostat is a highly sensitive low voltage device and is available in several different configurations from different manufacturers. The details listed b...
lang:en score:22 filesize: 68.93 K page_count: 2 document date: 2007-06-01
[pdf] User Manual
untitled Heating Seasonal Performance Factor Arcoaire Air Conditioner Parts Tempstar Manual DX1500 HP No Hassle arcoaire literature |||
15S E E R DX 1500 Heat Pump Generations of Americans have counted on the Arcoaire brand for home c ... me cool in the summer and warm in the winter. F. Evaporator/Indoor Coil, to match your Arcoaire air conditioner and furnace, assures you of optimum performance. G. UV Lights help prevent the growth of...
lang:en score:21 filesize: 908.8 K page_count: 4 document date: 2011-01-27
[pdf] Warranty
Layout 1 T4H3 TXH5 TSH5 N4H3 NXH5 TCH6 SERIES Tempstar Furnace Prices ITS Split tempstar pledge |||
Tempstar Split System Comparison HP MODEL SERIES AC MODEL SERIES MAINLINE MODELS TX 5300 TX 5400/ ... r sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR cri...
lang:en score:21 filesize: 191.32 K page_count: 1 document date: 2010-02-01
[pdf] Datasheet Warranty
Tempstar® Gas Furnaces n95esn hvacinformed datasheets tempstar gas furnace co 1573564033 ga |||
TempstarGas Furnaces Performance Series N95ESN/N92ESN/N80VSL/N80ES Heating and Cooling Products BU ... he gas furnace can also be combined with an indoor evaporator coil and properly matched outdoor air conditioner or heat pump to provide cooling during the warm seasons. N80 Gas Furnace WHAT SETS TEMP...
lang:en score:21 filesize: 761.23 K page_count: 4 document date: 2019-10-04
[pdf]
air conditioners Carrier COMFORT il y a 5 jours — Choose Tempstar heating and cooling equipment so you can enjoy comfort with confidence Our products deliver exceptional quality reliability energy  AC 004 TS 00 shareddocs hvac docs 1011 Public 0B |||
Performance Series AIR CONDITIONE RS Heating and Cooling Products COOL INDOOR COMFORT As an ENERGY ... one more example of how Tempstar goes the extra mile for your satisfaction. WHAT MATTERS IN AN AIR CONDITIONER ENERGY SAVINGS SEER2 Seasonal Energy Efficiency Ratio ratings are like your car s MPG...
lang:en score:21 filesize: 630.05 K page_count: 2 document date: 2022-06-09
[pdf] Borchure
ICP ACHP PERF SERIES COLOR BROCHURE TS shareddocs hvac docs 1011 Public 04
TempstarSplit System Air Conditioners Heat Pumps Performance Series N4A3, NH4A4, N4A4, NXA4/N4A5, NXA6/N4A6, NH4H4, N4H4, NXH5 Heating and Cooling Products WHAT SETS TEMPSTARAIR CONDITIONERS AND HEAT PUMPS APART 1. Durable galvanized steel construction with baked-on paint finish weathers seas...
lang:en score:21 filesize: 1.7 M page_count: 4 document date: 2016-05-10
[pdf] Installation Guide Accessories
Tempstar Flip book icpindexing toddsit userfiles |||
2011 International Comfort Products, LLC Check out these 12 WAYS that the new TSTAT0101SC wall co ... imple, menu-driven set-up of these systems: Up to 4 stages of heat Up to 2 stages of cooling Air conditioners, heat pumps, gas oil furnaces True dual fuel. COMMUNICATING INDOOR WITH NON-COMMUNIC...
lang:en score:21 filesize: 960.19 K page_count: 30 document date: 2011-12-07
[pdf] Warranty
Two Stage Heat Pumps 19 SEER Communicating System Count On Our Quiet We build the SmartComfort TXT with premium components for quiet performance The two stage scroll compressor a deluxe sound blanket is at heart of this machine 12tempst8176 M1rb Family HP 2 observer web icpindexing toddsit documents 086641 |||
up to SmartComfort TXT Two-Stage Heat Pumps 19 SEER Featuring The ObserverTM Communicating System ... r sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR cri...
lang:en score:21 filesize: 4.03 M page_count: 4 document date: 2012-06-14
[pdf] Warranty
Tempstar® Ultra Low NOx Gas Furnaces tempstar n95esu0601716a article 2277393384954572 en cl2 resource gemaire is content Watscocom Gemaire |||
TempstarUltra-Low NOx Gas Furnaces IonTM System F95CSU/F80CSU Performance Series N95ESU/N80ESU Heati ... ntrol District NOx emissions limits. Add an indoor evaporator coil and properly matched outdoor air conditioner or heat pump to provide cooling during the warm seasons. WHAT SETS TEMPSTAR ULTRA-LOW N...
lang:en score:20 filesize: 2.09 M page_count: 4 document date: 2019-10-10
[pdf] Warranty
Tempstar® Gas Furnaces limited warranty * WHAT IS A GAS FURNACE Tempstar gas furnaces are designed for the best durability and comfort The warmth efficiency of natural gas  tempstar n9mse1002120a article 1395692881702 en cl resource bakerdist is content Watscocom Gemaire |||
TempstarGas Furnaces Performance Series N9MSE/N9MSB/N8MX/N8MS Heating and Cooling Products BUILT W ... he gas furnace can also be combined with an indoor evaporator coil and properly matched outdoor air conditioner or heat pump to provide cooling during the warm seasons. Gas Furnace WHAT SETS TEMPSTAR...
lang:en score:20 filesize: 1.47 M page_count: 4 document date: 2016-02-12
[pdf] Warranty Catalog
10405 Tempstar F8MTL0451412A Catalog firstsupply UserFiles Documents inRiver Original
TempstarGas Furnaces SmartComfortDeluxe Series F9MAE/F9MVE/F8MVL SmartComfort Series F9MXT/F9MXE/F ... he gas furnace can also be combined with an indoor evaporator coil and properly matched outdoor air conditioner or heat pump to provide cooling during the warm seasons. 2 1 BUILT WITH STRENGTH When ...
lang:en score:20 filesize: 1.63 M page_count: 4 document date: 2016-06-17
[pdf] Warranty
Tempstar® Gas Furnaces WHAT IS A GAS FURNACE Tempstar gas furnaces are designed for durability and comfort The warmth efficiency of natural combined with a quiet 44022450001 TS shareddocs hvac docs 1011 Public 0E |||
TempstarGas Furnaces IonTM System F97CMN/F96CTN/ F80CTL QuietComfort Series F96VTN Heating and Coo ... he gas furnace can also be combined with an indoor evaporator coil and properly matched outdoor air conditioner or heat pump to provide cooling during the warm seasons. 2 1 * ** BUILT WITH STRENGTH...
lang:en score:20 filesize: 760.18 K page_count: 4 document date: 2019-10-04
[pdf]
tempstar personal use program firstsupply userfiles images hvac
TRY BEFORE YOU SELL PERSONAL USE PROGRAM A Carrier Company www.tempstar.com EXPERIENCE TEMPSTAR C ... s you and your team to try before you sell . Whether you purchase our newest line of furnaces, air conditioners or other eligible products, we think there will be no question in your mind about the q...
lang:en score:20 filesize: 1.5 M page_count: 3 document date: 2021-01-13
[pdf] Warranty
tempstar pgd448090ktp1g article 2277393384959909 en cl resource gemaire is content Watscocom Gemaire |||
TempstarPackaged Heating Cooling Systems BUILT WITH STRENGTH When you choose Tempstar heating and ... Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com. PAD4 PERFORMANCE 14 PACKAGED AIR CONDITIONER Up to 14.5 SEER/11 EER cooling efficiency Multi-speed blower motor for improved temper...
lang:en score:20 filesize: 547.02 K page_count: 2 document date: 2019-08-30
[pdf]
tempstar fas180maaa0a0a article 1416571831908 en cl fmt s7d2 scene7 is content Watscocom Gemaire |||
620 Commercial Split System Nominal Tons Air Conditioners and Heat Pumps EFRIGERANT ENTALLY SOUND R ... single circuit models or superior part load performance from two stages of cooling with the CAS air conditioner series or year-round energy savings with the CHS heat pump series, these units are desig...
lang:en score:20 filesize: 2.14 M page_count: 4 document date: 2012-12-04

tags: Air Conditioner, CONDITIONER, CSA6, CSA6 Split System Air Conditioner, HSA6, Split System Air Conditioner, TEMPSTAR, TSA6,

Search Any Device: