WaterFurnace 700R11 Indoor Split Geothermal Heat Pump User Manual

WaterFurnace Logo700R11 Indoor Split Geothermal Heat Pump 033, 042, 050 Variable Speed User Manual Submittal Data English Language/IP Units SD2703SNA 01/23 WaterFurnace 700R11 Indoor Split Geothermal Heat Pump

Contractor: P.O.: --------------- Engineer: ----------------------- Project Name: ----------------- Unit Tag: ----------------------

Unit Nomenclature (Compressor Section)

WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 1 Unit Nomenclature (Air Handler) WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 2 Notes: 1 - Air flow on the 050 unit in the horizontal configurations should be limited to 1900 cfm in cooling mode, or condensate blow off may occur. 2 - Compressor section mus t be matched with identical model SVH air handler section. See Compatibility Table 3 - To field convert the SVH to bottom flow air discharge. The SAHBCK kit must be ordered separately. 4 - UPC is not compatible with Symphony or IntelliZone2. AHRI/ISO 13256-1 Performance Ratings 7 Series Indoor Split Residential Series AHRI Data ECM Motor AHRI/ASHRAE/ISO 13256-1

 Model  Capacity Modulation   Flow Rate Clg/Htg Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling EWT 86°F Heating EWT 68°F Cooling EWT 59°F Heating EWT 50°F Cooling Full Load 77°F Part Load 68°F Heating Full Load 32°F Part Load 41°F
cfm Capacity Btuh EER Btuh/W Capacity Btuh COP Capacity Btuh EER Btuh/W Capacity Btuh COP Capacity Btuh EER Btuh/W Capacity Btuh COP
033 Full 1200/1500 31,600 16.8 49,800 5.2 37,000 29.2 40,700 4.5 33,300 20.3 31,700 3.4
Part 650/800 10,900 20.9 16,800 7.3 12,900 46.0 13,900 5.7 13,700 36.0 12,000 5.2
042 Full 1500/1800 39,500 16.4 66,100 4.9 46,200 28.2 54,100 4.2 41,600 19.7 42,700 3.5
Part 900/1100 15,600 22.4 23,800 7.5 17,300 52.0 18,800 5.8 17,500 40.8 15,800 5.1
050 Full 1800/2200 46,700 14.4 77,800 4.3 55,200 24.3 64,900 3.8 49,800 17.1 50,800 3.2
Part 950/1200 19,400 20.9 28,900 7.4 21,200 45.6 22,800 5.8 22,000 35.5 19,800 5.0
3/20/20 Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature Heating capacities based upon 68°F DB, 59°F WB entering air temperature All ratings based upon 208V operation Energy Star Compliance Table
Model Tier 3
Ground Water Ground Loop
033 Yes Yes
042 Yes Yes
050 Yes Yes
10/31/19

Energy Star Rating Criteria In order for water-source heat pumps to be Energy Star rated they must meet or exceed the minimum efficiency requirements listed below. Tier 3 represents the current minimum efficiency water source heat pumps must have in order to be Energy Start rated.

Tier 3: 1/1/2012 – No Effective End Date Published
Water-to-Air EER C COP
Ground Loop 17.1 3.6
Ground Water 21.1 4.1
Water-to-Water
Ground Loop 16.1 3.1
Ground Water 20.1 3.5
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Logo

Compressor Section Dimensional Data

WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 3

 Models  Height  Width  Depth Water In Water Out Service Valve HWG In HWG Out Low External Line KNOCK OUT KNOCK OUT
Liquid Gas Voltage Pump Voltage
A B C D E F G H J K L M N P
033-050 in. 21.25 25.62 31.60 2.30 7.21 16.40 18.30 10.30 13.30 12.10 14.30 9.50 4.70 9.10
cm. 54.00 65.10 80.30 5.80 18.50 41.70 46.50 26.20 33.80 30.70 36.30 24.10 11.90 23.10
Air Handler Dimensional Data - SVH Air Handler Top Flow/Horizontal Unit Configuration WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 4 SVH Air Handler - Topflow/Horizontal  BANG OLUFSEN Beosound Theatre Soundbar-

Condensate is plastic 3/4" FPT Discharge flange is field installed and extends 1" (25.4 mm) from cabinet NOTE: Clearance for maintenance and servicing access - minimum 30" from front of unit recommended for blower motor/coil replacement. Condensate drain lines routed to clear filter and panel access. Filter removal - minimum 30" recommended.

Air Handler Dimensional Data - SVH Air Handler Bottom Flow Unit Configuration WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 5 BANG OLUFSEN Beosound Theatre Soundbar-fig1

Condensate is plastic 3/4" FPT Discharge lange is kid installed and extends 1" (25.4 mm) from cabinet NOTE: Clearance for maintenance and servicing access - minimum 30° from front of unit recommended for blower motor/coil replacement. Condensate drain lines routed to clear filter and panel access. Filter removal - minimum 30° recommended.

Compressor Section Physical Data

Model NVZ033 NVZ042 NVZ050
Compressor (1 each) Variable Speed Scroll
Factory Charge R410a, oz [kg] 68 [1.93] 90 [2.55] 92 [2.61]
Coax and Water Piping
Water Connections Size - Swivel - in [mm] 1” [25.4] 1” [25.4] 1” [25.4]
HWG Connection Size - Female Sweat I.D. - in [mm] 1/2” [12.7] 1/2” [12.7] 1/2” [12.7]
Brass Service Valve - Liquid Line - in [mm] 3/8” [9.45]
Brass Service Valve - Suction Line - in [mm] 3/4” [19.1] 7/8” [22.23]
Coax & Piping Water Volume - gal [l] 1.3 [4.9] 2.3 [8.7] 2.3 [8.7]
Weight - Operating, lb [kg] 241 [109] 302 [137] 302 [137]
Weight - Packaged, lb [kg] 261 [118] 322 [146] 322 [146]
03/18/20 Notes: All units have an EEV and 1/2 in. [12.7mm], and 3/4 in. [19.1] electrical knockouts Brass services valves are sweat type valves Air Handler Physical Data
Air Handler Model Number (Refrigerant) 033 042 050
    Evaporator Coil Air Coil Total Face Area, ft2 [m2] 6.81 [0.63]
Tube outside diameter - in. [mm] 3/8 [9.52]
Number of rows 3
Fins per inch 12
Suction line connection - in. [mm] sweat 7/8 [22.23]
Liquid line connection - in. [mm] sweat 3/8 [9.45]
Refrigerant R-410a
Condensate drain connection - (FPT) in. [mm] 3/4 [19.05]
Blower Wheel Size (Dia x W), in. [mm] 11 x 10 [279 x 254]
Blower motor type/speeds Variable Speed ECM
Blower motor output - hp [W] 1 [746]
Filter Standard - 1” [51mm] Field Supplied. 22 X 20 [559 x 508]
Electrical characteristics (60hz) 208/230 - 1ph
Shipping weight - lbs. [kg] 206 [93.4]
Operating weight - lbs. [kg] 188 [85.3]

Auxiliary Heat Compatibility

Model kW Stages Min CFM
033 042 050
19P659-02 10 2 1300
19P659-03 15 2 1700
19P659-04 20 2 2000
03/12/20 Air Handler Auxiliary Heat Blower Settings
Model Variable Speed ECM DIP Setting
SVH033 10
SVH042 11
SVH050 11
6/6/2019

Electrical Data

Variable speed with external loop pump

  Model   Rated Voltage   Voltage Min/Max   COMP LRA   COMP MCC   Drive RLA Drive Internal Fuse HWG Pump FLA Ext Loop FLA Total Unit FLA Minimum Circuit Amp Max Fuse HACR Breaker
033 208-230/60/1 187/253 10.2 18.0 22.0 30.0 0.4 5.4 27.8 33.3 35
042 208-230/60/1 187/253 12.0 23.5 28.0 35.0 0.4 5.4 33.8 40.8 45
050 208-230/60/1 187/253 12.0 30.0 33.0 40.0 0.4 5.4 38.8 47.1 50
8/21/19 Rated Voltage of 208/230/60/1 HACR circuit breaker in USA only All fuses Class RK-5 Air Handler Electrical Data 
  Model Electric Heat Capacity   Supply Circuit Aux. Heat Minimum CFM   Rated Voltage   Voltage Min/Max Fan Motor FLA Heater Am- pacity Total Unit FLA Minimum Circuit Am- pacity Maximum Fuse/HACR
KW BTUH
240v 240v 208v 240v 208v 240v 208v 240v 208v 240v
033 0 0 -             208- 30/60/1             197/253 7.0 - - 7.0 7.0 8.8 8.8 15 15
9.6 32,765 single 1,300 7.0 34.7 40.0 41.7 47.0 52.1 58.8 60 60
    042 0 0 - 7.0 - - 7.0 7.0 8.8 8.8 15 15
9.6 32,765 single 1,300 7.0 34.7 40.0 41.7 47.0 52.1 58.8 60 60
14.4 49,147 single   1,700 7.0 52.0 60.0 59.0 67.0 73.8 83.8 80 90
14.4 49,147 L1/L2 7.0 34.7 40.0 41.7 47.0 52.1 58.8 60 60
L3/L4 - 17.3 20.0 17.3 20.0 21.6 25.0 25 25
      050 0 0 - 7.0 - - 7.0 7.0 8.8 8.8 15 15
9.6 32,765 single 1,300 7.0 34.7 40.0 41.7 47.0 52.1 58.8 60 60
14.4 49,147 single   1,700 7.0 52.0 60.0 59.0 67.0 73.8 83.8 80 90
14.4 49,147 L1/L2 7.0 34.7 40.0 41.7 47.0 52.1 58.8 60 60
L3/L4 - 17.3 20.0 17.3 20.0 21.6 25.0 25 25
19.2 65,530 single   2,000 7.0 69.3 80.0 76.3 87.0 95.4 108.8 100 110
19.2 65,530 L1/L2 7.0 34.7 40.0 41.7 47.0 52.1 58.8 60 60
L3/L4 - 34.7 40.0 34.7 40.0 43.4 50.0 50 50
1/29/20 Rated Voltage of 208/230/60/1 HACR circuit breaker in USA only

SVH Blower Performance Data

Variable Speed ECM

Model Max ESP Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12
033 0.75 250 400 G 550 L 650 750 850 1000 1150 1250 H 1350 Aux 1450 1600
042 0.75 250 450 G 650 L 800 950 1050 1200 1350 1450 1600 H 1750 Aux 1850
050 0.75 300 550 G 800 L 1000 1150 1300 1450 1600 1750 1900 H 2050 Aux 2200
**VS Com- pressor Speed   1-2   3-4   5-6   7-8   9-10   11-12
4/15/2020 ** VS Compressor speed is given for the factory default cfm settings. When the cfm default settings are changed it will change the relationship to the compressor speed that is shown in the table. In cooling mode compressor speeds 10-12 are only available when SuperBoost mode is selected at the thermostat. Factory settings are at recommended G, L , H and Aux positions “G” may be located anywhere within the airflow table. “L” setting should be located within the boldface CFM range “H” setting MUST be located within the shaded CFM range “Aux” setting MUST be equal to or higher than factory setting shown in the table above CFM is controlled within 5% up to the maximum ESP

Line Set Sizes

NOTE: Manufacturer recommends the standard total line set length not to exceed 80 ft with no more than 25 ft of vertical separation between the compressor section and the air handler. For installations that exceed the standard range refer to the Long Line Set Application Guide AG2200EW for further installation requirements.

Unit Air 20 feet 40 feet 60 feet 80 feet NZ Factory Charge (oz.) *Charge Amount with SVH Air Handler (oz.)
  Size   Handler   Suction   Liquid   Suction   Liquid   Suction   Liquid   Suction   Liquid
NVZ033 SVH033 3/4” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 3/8” OD 68 118
NVZ042 SVH042 3/4” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 3/8” OD 90 142
NVZ050 SVH050 3/4” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 3/8” OD 7/8” OD 3/8” OD 92 152
CAPACITY MULTIPLIER 1.00 0.985 0.97 0.955

Notes: * The “Charge Amount with SVH Air Handler” column is based on the charge amount for a SVH Air Handler + Compressor Section/Split. Additional charge will need to be added accordingly for line set length. After charge is added, additional adjustments can be made to get appropriate subcooling and superheat measurements. Additional charge for R410A is 0.50 oz. per ft. for 3/8” and 1.0 oz. per ft. for 1/2” tube. Longer line sets will significantly reduce capacity and efficiency of the system as well as adversely effect the system reliability due to poor oil return.

Operating Limits

Operating Limits Cooling Heating
(°F) (°C) (°F) (°C)
Air Limits
Min. Ambient Air 45 7.2 45 7.2
Rated Ambient Air 80 26.7 70 21.1
Max. Ambient Air 100 37.8 85 29.4
Min. Entering Air 50 10.0 40 4.4
Rated Entering Air db/wb 80.6/66.2 27/19 68 20.0
Max. Entering Air db/wb 110/83 43/28.3 80 26.7
Water Limits
Min. Entering Water 30 -1.1 20 -6.7
Normal Entering Water 50-110 10-43.3 30-70 -1.1
Max. Entering Water 120 48.9 90 32.2
NOTE: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. The operating limits are dependent upon three primary factors: 1) water temperature, 2) return air temperature, and 3) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation.

Definitions

Abbreviations and Definitions cfm = airflow, cubic feet/minute EWT = entering water temperature, Fahrenheit gpm = water flow in gallons/minute WPD = water pressure drop, psi and feet of water EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) HC = air heating capacity, MBtu/h TC = total cooling capacity, MBtu/h SC = sensible cooling capacity, MBtu/h kW = total power unit input, kilowatts HR = total heat of rejection, MBtu/h HE = total heat of extraction, MBtu/h HWC = hot water generator capacity, MBtu/h EER = Energy Efficient Ratio = Btu output/Watt input COP = Coefficient of Performance = Btu output/Btu input LWT = leaving water temperature, °F LAT = leaving air temperature, °F TH = total heating capacity, MBtu/h LC = latent cooling capacity, MBtu/h S/T = sensible to total cooling ratio Compressor Section Pressure Drop

Model GPM Pressure Drop (psi)
30° F 50° F 70° 90° F 110° F
  033 11.5 3.60 3.30 3.10 2.90 2.70
9.0 2.30 2.10 2.00 1.90 1.70
7.0 2.10 2.00 1.80 1.80 1.60
6.0 1.10 1.05 1.00 0.90 0.85
4.5 0.70 0.66 0.64 0.60 0.55
  042 13.5 4.10 3.80 3.60 3.40 3.10
10.5 1.90 1.80 1.70 1.60 1.50
7.5 1.70 1.50 1.40 1.30 1.20
6.0 1.00 0.90 0.80 0..7 0.60
4.0 0.40 0.38 0.36 0.34 0.30
  050 17.0 6.20 5.80 5.40 5.00 4.60
13.5 3.90 3.70 3.50 3.10 2.90
9.5 1.90 1.80 1.70 1.60 1.50
7.5 1.40 1.30 1.20 1.10 0.90
5.0 0.60 0.55 0.50 0.45 0.40
8/21/2019 Thermistor Resistance
Thermistor Resistance (10k Ohm) for FP1, FP2, HWL, LWT and LLT (EWT with Performance Option) Thermistor Resistance (1k Ohm) for compressor discharge line, suction line, LAT, compressor ambient and EWT
Thermistor Temperature (°F) Thermistor Resistance (Ohms) Thermistor Temperature (°F) Thermistor Resistance (Ohms)
5 75757-70117 20 974.4-973.4
14 57392-53234 25 985.4-984.4
23 43865-40771 30 996.1-995.1
32 33809-31487 35 1007.0-1006.0
41 26269-24513 40 1017.8-1016.8
50 20570-19230 45 1028.6-1027.6
59 16226-15196 50 1039.5-1038.5
68 12889-12093 55 1050.2-1049.2
77 10310-9688 60 1061.2-1060.2
86 8300-7812 65 1072.9-1071.9
95 6723-6337 70 1082.7-1081.7
104 5480-5172 75 1093.4-1092.4
113 4490-4246 80 1103.0-1102.0
122 3700-3504 85 1115.5-1114.5
131 3067-2907 90 1126.2-1125.2
140 2554-2424 95 1136.6-1135.6
149 2149-2019 100 1147.2-1146.2
4/24/12 105 1158.1-1157.1
110 1168.8-1167.8
115 1179.4-1178.4
120 1190.1-1189.1
125 1200.3-1199.3
130 1212.2-1211.2

Correction Factor Tables

Air Flow Corrections (Compressor Speeds 1-3)

Airflow Cooling Heating
CFM Per Ton of Clg % of Nominal Total Cap Sens Cap Power Heat of Rej Htg Cap Power Heat of Ext
240 60 0.940 0.740 0.967 0.951 0.943 1.106 0.902
275 69 0.950 0.783 0.973 0.959 0.953 1.088 0.918
300 75 0.960 0.827 0.978 0.967 0.962 1.070 0.935
325 81 0.970 0.870 0.984 0.975 0.972 1.053 0.951
350 88 0.980 0.913 0.989 0.984 0.981 1.035 0.967
375 94 0.990 0.957 0.995 0.992 0.991 1.018 0.984
400 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000
425 106 1.030 1.022 1.024 1.026 1.009 0.982 1.016
450 113 1.060 1.045 1.048 1.051 1.019 0.965 1.033
475 119 1.091 1.067 1.071 1.077 1.028 0.947 1.049
500 125 1.121 1.089 1.095 1.103 1.038 0.930 1.065
520 130 1.151 1.111 1.110 1.129 1.047 0.912 1.082
6/29/12 Air Flow Corrections (Compressor Speeds 4-12)
Airflow Cooling Heating
CFM Per Ton of Clg % of Nominal Total Cap Sens Cap Power Heat of Rej Htg Cap Power Heat of Ext
240 60 0.928 0.747 0.936 0.929 0.961 1.097 0.938
275 69 0.940 0.789 0.946 0.941 0.967 1.081 0.948
300 75 0.952 0.831 0.957 0.953 0.974 1.064 0.959
325 81 0.964 0.873 0.968 0.965 0.980 1.048 0.969
350 88 0.976 0.916 0.979 0.976 0.987 1.032 0.979
375 94 0.988 0.958 0.989 0.988 0.993 1.016 0.990
400 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000
425 106 1.020 1.023 1.004 1.018 1.010 0.966 1.018
450 113 1.056 1.042 1.008 1.035 1.020 0.932 1.036
475 119 1.072 1.079 1.011 1.053 1.029 0.898 1.054
500 125 1.087 1.095 1.015 1.070 1.039 0.865 1.071
520 130 1.099 1.113 1.019 1.088 1.049 0.831 1.089
6/14/12 Cooling Capacity Corrections
Entering Air WB ° F Total Clg Cap Sensible Cooling Capacity Multipliers - Entering DB ° F Power Input Heat of Rejection
60 65 70 75 80 80.6 85 90 95 100
55 0.898 0.723 0.866 1.048 1.185 * * * * * * 0.985 0.913
60 0.912 0.632 0.880 1.078 1.244 1.260 * * * * 0.994 0.927
63 0.945 0.768 0.960 1.150 1.175 * * * * 0.996 0.954
65 0.976 0.694 0.881 1.079 1.085 1.270 * * * 0.997 0.972
66.2 0.983 0.655 0.842 1.040 1.060 1.232 * * * 0.999 0.986
67 1.000 0.616 0.806 1.000 1.023 1.193 1.330 1.480 * 1.000 1.000
70 1.053 0.693 0.879 0.900 1.075 1.205 1.404 * 1.003 1.044
75 1.168 0.687 0.715 0.875 1.040 1.261 1.476 1.007 1.141
1/5/2017 NOTE: *Sensible capacity equals total capacity at conditions shown. Heating Capacity Corrections
Ent Air DB °F Heating Corrections
Htg Cap Power Heat of Ext
45 1.062 0.739 1.158
50 1.050 0.790 1.130
55 1.037 0.842 1.096
60 1.025 0.893 1.064
65 1.012 0.945 1.030
68 1.005 0.976 1.012
70 1.000 1.000 1.000
75 0.987 1.048 0.970
80 0.975 1.099 0.930
Antifreeze Corrections Catalog performance can be corrected for antifreeze use. Please use the following table and note the example given.
Antifreeze Type Antifreeze % by wt Heating Cooling Pressure Drop
EWT - °F [°C] 30 [-1.1] 90 [32.2] 30 [-1.1]
Water 0 1.000 1.000 1.000
    Ethylene Glycol 10 0.973 0.991 1.075
20 0.943 0.979 1.163
30 0.917 0.965 1.225
40 0.890 0.955 1.324
50 0.865 0.943 1.419
    Propylene Glycol 10 0.958 0.981 1.130
20 0.913 0.969 1.270
30 0.854 0.950 1.433
40 0.813 0.937 1.614
50 0.770 0.922 1.816
    Ethanol 10 0.927 0.991 1.242
20 0.887 0.972 1.343
30 0.856 0.947 1.383
40 0.815 0.930 1.523
50 0.779 0.911 1.639
    Methanol 10 0.957 0.986 1.127
20 0.924 0.970 1.197
30 0.895 0.951 1.235
40 0.863 0.936 1.323
50 0.833 0.920 1.399
Warning icon WARNING: Gray area represents antifreeze concentrations greater than 35% by weight and should be avoided due to the extreme performance penalty they represent. Antifreeze Correction Example Antifreeze solution is Propylene Glycol 20% by weight. Determine the corrected heating and cooling performance at 30°F and 90°F respectively as well as pressure drop at 30°F for a 033 operating at 100% capacity. The corrected cooling capacity at 90°F would be: 30,500 Btu/h x 0.969 = 29,554 Btu/h The corrected heating capacity at 30°F would be: 34,100 Btu/h x 0.913 = 31,133 Btu/h The corrected pressure drop at 30°F and 11.5 gpm would be: 7.9 feet of head x 1.270 = 10.03 feet of head

Performance Data

NVZ033 - 50% Part Load

  EWT °F   Flow gpm WPD HEATING - EAT 70°F   EWT °F   Flow gpm WPD COOLING - EAT 80/67 °F
PSI FT Airflow cfm HC MBtuh Power kW HE MBtuh LAT °F COP HWC MBtuh PSI FT Airflow cfm TC MBtuh SC MBtuh S/T Ratio Power kW HR MBtuh EER HWC MBtuh
  20 3.0 0.5 1.1 Operation not recommended   20 2.5 0.2 0.5  Operation not recommended
4.5 0.7 1.6 3.5 0.5 1.1
6.0 1.2 2.7 550 12.4 1.48 7.2 90.6 2.43 2.2 4.5 0.7 1.6
750 12.7 1.37 8.0 85.7 2.72 1.9
    30 3.0 0.5 1.1 550 13.1 1.22 8.3 91.0 3.00 2.0     30 2.5 0.2 0.5 500 17.8 12.8 0.72 0.54 18.8 31.6 -
750 13.6 1.25 8.7 86.1 3.04 1.7 650 18.1 14.0 0.77 0.56 19.2 30.9 -
4.5 0.7 1.6 550 13.4 1.23 8.6 91.6 3.06 2.1 3.5 0.5 1.1 500 18.0 12.9 0.71 0.51 18.9 33.7 -
750 14.0 1.26 9.0 86.5 3.11 1.8 650 18.3 14.1 0.77 0.54 19.3 32.5 -
6.0 1.1 2.6 550 14.6 1.39 9.0 93.1 2.89 2.2 4.5 0.7 1.6 500 18.1 12.9 0.71 0.50 19.0 34.9 -
750 14.9 1.29 9.8 87.5 3.23 1.9 650 18.6 14.1 0.76 0.52 19.5 34.0 -
    40 3.0 0.4 1.0 550 15.6 1.27 11.0 95.8 3.55 2.0     40 2.5 0.2 0.5 500 19.3 13.2 0.68 0.59 20.4 31.1 -
750 16.2 1.29 11.5 89.6 3.60 1.8 650 19.7 14.5 0.73 0.62 20.9 30.5 -
4.5 0.7 1.5 550 16.1 1.27 11.5 96.6 3.65 2.1 3.5 0.4 1.0 500 19.6 13.4 0.68 0.56 20.6 33.2 -
750 16.7 1.29 12.0 90.2 3.71 1.9 650 19.9 14.6 0.73 0.59 21.0 32.2 -
6.0 1.1 2.5 550 17.0 1.30 12.2 98.1 3.76 2.2 4.5 0.7 1.5 500 19.7 13.4 0.68 0.55 20.6 34.5 -
750 17.6 1.33 12.7 91.3 3.82 2.0 650 20.2 14.6 0.72 0.57 21.1 33.7 -
    50 3.0 0.4 1.0 550 18.2 1.31 13.7 100.6 4.06 2.5     50 2.5 0.2 0.5 500 20.6 13.2 0.64 0.63 21.8 31.2 -
750 18.8 1.33 14.2 93.2 4.13 2.2 650 21.2 14.7 0.69 0.64 22.4 31.4 -
4.5 0.6 1.5 550 18.8 1.31 14.4 101.7 4.20 2.5 3.5 0.4 1.0 500 20.8 13.3 0.64 0.61 21.9 32.3 -
750 19.4 1.33 14.9 94.0 4.28 2.3 650 21.4 14.7 0.69 0.63 22.5 32.6 -
6.0 1.1 2.5 550 19.7 1.34 15.1 103.2 4.30 2.6 4.5 0.6 1.5 500 21.1 13.7 0.65 0.61 22.2 33.1 -
750 20.3 1.36 15.7 95.1 4.37 2.4 650 21.7 15.1 0.70 0.62 22.8 33.4 -
    60 3.0 0.4 1.0 550 20.7 1.33 16.1 104.8 4.55 2.7     60 2.5 0.2 0.5 500 20.0 13.2 0.66 0.74 21.6 25.6 1.3
750 21.2 1.34 16.6 96.2 4.63 2.5 650 20.5 14.6 0.71 0.76 22.1 25.9 1.4
4.5 0.6 1.4 550 21.5 1.33 17.0 106.2 4.74 2.8 3.5 0.4 1.0 500 20.2 13.3 0.66 0.72 21.7 26.6 1.2
750 22.0 1.34 17.4 97.2 4.83 2.6 650 20.7 14.7 0.71 0.74 22.2 26.8 1.3
6.0 1.0 2.4 550 22.3 1.36 17.6 107.5 4.80 2.9 4.5 0.6 1.4 500 20.5 13.6 0.66 0.72 22.0 27.2 1.1
750 22.8 1.37 18.1 98.1 4.88 2.7 650 21.1 15.1 0.72 0.73 22.5 27.5 1.2
    70 3.0 0.4 0.9 550 23.1 1.35 18.5 108.9 5.03 3.1     70 2.5 0.2 0.5 500 19.3 13.2 0.68 0.85 21.3 21.6 1.7
750 23.6 1.32 19.1 99.1 5.24 2.8 650 19.9 14.6 0.73 0.87 21.9 21.7 1.8
4.5 0.6 1.4 550 24.1 1.34 19.6 110.6 5.27 3.2 3.5 0.4 0.9 500 19.5 13.2 0.68 0.83 21.4 22.3 1.6
750 24.6 1.34 20.0 100.4 5.37 2.9 650 20.0 14.6 0.73 0.85 22.0 22.5 1.7
6.0 1.0 2.3 550 24.8 1.37 20.1 111.7 5.29 3.3 4.5 0.6 1.4 500 19.8 13.6 0.68 0.82 21.7 22.9 1.5
750 25.2 1.37 20.5 101.1 5.39 2.7 650 20.4 15.0 0.74 0.84 22.3 23.1 1.7
    80 3.0 0.4 0.9 550 25.4 1.34 20.9 112.8 5.57 3.7     80 2.5 0.2 0.4 500 18.5 12.9 0.70 0.93 20.8 18.8 2.3
750 25.8 1.33 21.2 101.8 5.68 3.4 650 19.0 14.3 0.75 0.95 21.3 19.0 2.5
4.5 0.6 1.3 550 26.6 1.33 22.1 114.9 5.87 3.9 3.5 0.4 0.9 500 18.6 13.0 0.69 0.91 20.9 19.5 2.2
750 27.0 1.32 22.5 103.3 5.99 3.5 650 19.2 14.3 0.75 0.93 21.4 19.7 2.4
6.0 1.0 2.2 550 27.0 1.36 22.4 115.5 5.84 4.0 4.5 0.6 1.3 500 19.0 13.3 0.70 0.90 21.1 20.0 2.0
750 27.3 1.35 22.7 103.7 5.95 3.7 650 19.5 14.7 0.75 0.92 21.7 20.2 2.2
    90 3.0 0.4 0.9 550 27.7 1.33 23.2 116.7 6.12 4.3     90 2.5 0.2 0.4 500 17.6 12.6 0.71 1.02 20.3 16.5 3.0
750 27.9 1.31 23.5 104.5 6.25 4.0 650 18.1 13.9 0.77 1.04 20.8 16.7 3.2
4.5 0.6 1.3 550 29.1 1.32 24.7 119.1 6.49 4.5 3.5 0.4 0.9 500 17.8 12.7 0.71 0.99 20.3 17.1 2.9
750 29.3 1.30 24.9 106.2 6.63 4.1 650 18.3 14.0 0.77 1.01 20.9 17.3 3.1
6.0 0.9 2.2 550 29.3 1.34 24.7 119.3 6.40 4.6 4.5 0.6 1.3 500 17.6 12.3 0.70 1.17 20.8 14.4 2.8
750 29.4 1.32 24.9 106.3 6.53 4.3 650 18.6 14.4 0.77 1.00 21.1 17.7 2.6
    100 3.0 0.4 0.8               Operation not recommended     100 2.5 0.2 0.4 500 16.7 12.4 0.74 1.34 20.5 11.9 3.6
650 17.2 13.7 0.80 1.36 21.0 12.0 3.8
4.5 0.5 1.2 3.5 0.4 0.8 500 16.9 12.4 0.74 1.30 20.5 12.4 3.3
650 17.4 13.8 0.79 1.33 21.1 12.5 3.6
6.0 0.9 2.1 4.5 0.5 1.2 500 17.2 12.8 0.74 1.29 20.7 12.7 3.0
650 17.6 14.1 0.80 1.32 21.3 12.8 3.4
    110 3.0 0.3 0.8     110 2.5 0.2 0.4 500 15.8 12.1 0.77 1.66 20.7 9.1 4.7
650 16.3 13.4 0.83 1.69 21.3 9.2 5.0
4.5 0.5 1.2 3.5 0.3 0.8 500 16.0 12.2 0.76 1.61 20.7 9.4 4.4
650 16.4 13.5 0.82 1.64 21.3 9.5 4.8
6.0 0.9 2.0 4.5 0.5 1.2 500 16.2 12.5 0.77 1.60 20.9 9.7 4.1
650 16.7 13.9 0.83 1.63 21.5 9.8 4.6
    120 3.0 0.3 0.8     120 2.5 0.2 0.4 500 13.2 12.1 0.92 1.95 19.2 6.4 6.2
650 13.5 13.2 0.98 2.00 19.6 6.4 6.0
4.5 0.5 1.2 3.5 0.3 0.8 500 13.4 12.2 0.91 1.84 19.0 6.9 5.5
650 13.6 13.2 0.97 1.89 19.4 6.8 5.9
6.0 0.8 1.9 4.5 0.5 1.2 500 13.5 12.2 0.90 1.78 18.9 7.2 5.0
650 13.8 13.2 0.96 1.84 19.4 7.1 5.6
3/27/2020 Performance Data cont. NVZ033 - 100% Full Load
  EWT °F   Flow gpm WPD HEATING - EAT 70°F   EWT °F   Flow gpm WPD COOLING - EAT 80/67 °F
PSI FT Airflow cfm HC MBtuh Power kW HE MBtuh LAT °F COP HWC MBtuh PSI FT Airflow cfm TC MBtuh SC MBtuh S/T Ratio Power kW HR MBtuh EER HWC MBtuh
  20 6.0 1.5 3.5 Operation not recommended   20 4.5 0.7 1.6   Operation not recommended
9.0 2.3 5.4 6.5 1.5 3.5
12.0 4.1 9.5 1150 27.6 2.94 17.6 92.2 2.75 3.0 9.0 2.3 5.4
1500 28.7 2.80 19.1 87.7 3.00 2.7
    30 6.0 1.5 3.4 1150 31.7 2.70 22.5 95.5 3.44 3.1     30 4.5 0.7 1.6 1000 34.6 22.1 0.64 1.14 38.5 30.4 -
1500 32.6 2.79 23.1 90.1 3.42 2.8 1200 35.2 24.3 0.69 1.18 39.3 29.8 -
9.0 2.3 5.3 1150 32.5 2.74 23.1 96.2 3.48 3.2 6.5 1.5 3.4 1000 35.1 22.3 0.64 1.08 38.7 32.5 -
1500 33.4 2.82 23.8 90.6 3.47 2.9 1200 35.6 24.4 0.68 1.14 39.5 31.3 -
12.0 4.0 9.2 1150 32.8 2.99 22.6 96.4 3.22 3.2 9.0 2.3 5.3 1000 35.2 22.3 0.63 1.05 38.8 33.6 -
1500 34.1 2.85 24.4 91.0 3.51 2.9 1200 36.1 24.4 0.68 1.10 39.9 32.8 -
    40 6.0 1.4 3.3 1150 35.4 2.84 25.7 98.5 3.66 3.3     40 4.5 0.7 1.5 1000 35.4 23.6 0.67 1.31 39.9 27.1 -
1500 36.5 2.91 26.5 92.5 3.67 3.1 1200 36.1 25.9 0.72 1.36 40.7 26.5 -
9.0 2.2 5.1 1150 36.5 2.89 26.7 99.4 3.70 3.4 6.5 1.4 3.3 1000 35.8 23.9 0.67 1.24 40.1 28.8 -
1500 37.7 2.96 27.6 93.2 3.73 3.1 1200 36.5 26.1 0.71 1.30 40.9 28.0 -
12.0 3.9 8.9 1150 37.3 2.92 27.3 100.0 3.74 3.5 9.0 2.2 5.1 1000 36.1 23.9 0.66 1.20 40.2 30.0 -
1500 38.5 2.99 28.3 93.7 3.78 3.2 1200 36.9 26.1 0.71 1.26 41.2 29.3 -
    50 6.0 1.4 3.2 1150 39.2 2.98 29.0 101.5 3.85 3.7     50 4.5 0.6 1.5 1000 34.7 23.1 0.66 1.47 39.7 23.6 -
1500 40.3 3.02 30.0 94.9 3.91 3.4 1200 36.5 25.7 0.70 1.55 41.8 23.6 -
9.0 2.1 4.9 1150 40.6 3.05 30.2 102.7 3.90 3.8 6.5 1.4 3.2 1000 35.5 23.4 0.66 1.39 40.2 25.6 -
1500 41.9 3.09 31.3 95.9 3.97 3.5 1200 37.3 25.9 0.70 1.45 42.2 25.6 -
12.0 3.7 8.6 1150 41.5 3.08 31.0 103.4 3.95 3.9 9.0 2.1 4.9 1000 35.8 24.9 0.70 1.35 40.4 26.5 -
1500 42.8 3.12 32.2 96.4 4.02 3.6 1200 37.7 27.7 0.73 1.42 42.5 26.5 -
    60 6.0 1.3 3.1 1150 43.4 3.03 33.1 105.0 4.20 4.1     60 4.5 0.6 1.4 1000 32.9 23.4 0.71 1.68 38.6 19.6 1.9
1500 44.8 3.05 34.4 97.7 4.31 3.8 1200 34.5 26.0 0.75 1.75 40.4 19.7 2.1
9.0 2.1 4.8 1150 45.4 3.11 34.7 106.5 4.27 4.3 6.5 1.3 3.1 1000 33.6 23.7 0.70 1.59 39.1 21.1 1.8
1500 46.8 3.13 36.1 98.9 4.38 3.9 1200 35.2 26.2 0.74 1.66 40.9 21.2 2.0
12.0 3.6 8.4 1150 46.5 3.15 35.7 107.4 4.33 4.4 9.0 2.1 4.8 1000 34.0 24.9 0.73 1.55 39.3 21.9 1.7
1500 48.0 3.16 37.2 99.6 4.45 4.0 1200 35.7 27.7 0.78 1.63 41.2 21.9 1.9
    70 6.0 1.3 3.0 1150 47.7 3.07 37.2 108.4 4.55 4.6     70 4.5 0.6 1.4 1000 31.0 23.7 0.76 1.92 37.6 16.2 2.4
1500 49.1 3.15 38.4 100.3 4.57 4.3 1200 32.1 25.4 0.79 1.98 38.9 16.2 2.5
9.0 2.0 4.6 1150 50.2 3.17 39.3 110.4 4.63 4.8 6.5 1.3 3.0 1000 31.8 24.0 0.75 1.80 38.0 17.7 2.2
1500 51.8 3.17 41.0 102.0 4.78 4.4 1200 33.2 26.5 0.80 1.87 39.6 17.8 2.4
12.0 3.5 8.1 1150 51.4 3.21 40.5 111.4 4.69 4.9 9.0 2.0 4.6 1000 32.2 24.9 0.77 1.76 38.2 18.3 2.0
1500 53.2 3.20 42.3 102.8 4.87 4.5 1200 33.6 27.6 0.82 1.83 39.8 18.4 2.3
    80 6.0 1.3 2.9 1150 51.0 3.18 40.1 111.1 4.70 5.2     80 4.5 0.6 1.3 1000 29.6 23.5 0.79 2.14 36.9 13.8 2.9
1500 52.8 3.16 42.0 102.6 4.90 4.9 1200 30.8 26.2 0.85 2.21 38.4 14.0 3.1
9.0 1.9 4.5 1150 53.9 3.31 42.7 113.4 4.78 5.4 6.5 1.3 2.9 1000 30.5 23.8 0.78 2.07 37.5 14.7 2.7
1500 55.8 3.27 44.6 104.4 4.99 5.0 1200 31.7 26.4 0.83 2.13 38.9 14.9 3.0
12.0 3.4 7.8 1150 55.5 3.35 44.1 114.7 4.86 5.6 9.0 1.9 4.5 1000 30.8 24.4 0.79 2.02 37.7 15.2 2.5
1500 57.4 3.30 46.1 105.4 5.10 5.1 1200 32.1 27.1 0.84 2.09 39.2 15.4 2.8
    90 6.0 1.2 2.8 1150 54.3 3.29 43.1 113.7 4.84 5.9     90 4.5 0.6 1.3 1000 28.3 23.4 0.83 2.40 36.4 11.8 3.7
1500 56.2 3.24 45.2 104.7 5.09 5.5 1200 29.3 26.0 0.89 2.46 37.6 11.9 3.9
9.0 1.9 4.3 1150 57.7 3.44 46.0 116.5 4.92 6.1 6.5 1.2 2.8 1000 29.1 23.7 0.82 2.33 37.0 12.5 3.4
1500 59.8 3.38 48.3 106.9 5.19 5.7 1200 30.2 26.3 0.87 2.39 38.3 12.6 3.7
12.0 3.3 7.5 1150 59.6 3.49 47.7 117.9 5.01 6.3 9.0 1.9 4.3 1000 29.8 24.0 0.81 2.33 37.7 12.8 3.2
1500 61.6 3.40 50.0 108.0 5.31 5.8 1200 30.5 26.5 0.87 2.34 38.5 13.0 4.1
    100 6.0 1.2 2.7               Operation not recommended     100 4.5 0.5 1.2 1000 26.8 23.2 0.87 2.73 36.1 9.8 4.4
1200 27.6 25.7 0.93 2.78 37.1 9.9 4.8
9.0 1.8 4.2 6.5 1.2 2.7 1000 27.7 23.5 0.85 2.68 36.8 10.3 4.1
1200 28.6 26.1 0.91 2.72 37.9 10.5 4.5
12.0 3.1 7.3 9.0 1.8 4.2 1000 28.0 23.4 0.84 2.63 37.0 10.6 3.8
1200 28.9 25.9 0.90 2.68 38.0 10.8 4.3
    110 6.0 1.1 2.6     110 4.5 0.5 1.2 1000 25.3 23.0 0.91 3.06 35.8 8.3 5.6
1200 26.0 25.5 0.98 3.10 36.6 8.4 5.9
9.0 1.7 4.0 6.5 1.1 2.6 1000 26.3 23.2 0.88 3.03 36.7 8.7 5.2
1200 27.0 25.8 0.96 3.05 37.4 8.9 5.6
12.0 3.0 7.0 9.0 1.7 4.0 1000 26.6 22.9 0.86 2.98 36.7 8.9 4.8
1200 27.3 25.3 0.93 3.01 37.6 9.1 5.3
    120 6.0 1.1 2.5     120 4.5 0.5 1.2 1000 24.4 22.1 0.90 3.60 36.7 6.8 6.7
1200 25.0 24.1 0.97 3.69 37.5 6.8 7.1
9.0 1.7 3.8 6.5 1.1 2.5 1000 24.7 22.3 0.90 3.41 36.4 7.3 6.2
1200 25.2 24.2 0.96 3.49 37.1 7.2 6.7
12.0 2.9 6.7 9.0 1.7 3.8 1000 25.0 22.3 0.89 3.30 36.2 7.6 6.4
1200 25.5 24.2 0.95 3.40 37.1 7.5 7.1
Performance Data cont. NVZ042 - 50% Part Load
  EWT °F   Flow gpm WPD HEATING - EAT 70°F   EWT °F   Flow gpm WPD COOLING - EAT 80/67 °F
PSI FT Airflow cfm HC MBtuh Power kW HE MBtuh LAT °F COP HWC MBtuh PSI FT Airflow cfm TC MBtuh SC MBtuh S/T Ratio Power kW HR MBtuh EER HWC MBtuh
  20 3.7 0.4 0.8 Operation not recommended   20 3.0 0.2 0.5  Operation not recommended
5.2 0.7 1.6 4.4 0.6 1.4
6.7 1.2 2.7 700 16.6 1.73 10.7 91.9 2.81 2.7 5.8 0.9 2.2
900 16.9 1.66 11.2 87.4 2.98 2.3
    30 3.7 0.3 0.8 700 17.1 1.56 11.8 92.6 3.20 2.6     30 3.0 0.2 0.5 650 23.3 15.7 0.67 0.59 24.2 37.8 -
900 17.7 1.59 12.2 88.2 3.26 2.2 750 23.8 17.2 0.73 0.61 24.7 36.9 -
5.2 0.7 1.6 700 18.5 1.63 12.9 94.4 3.31 2.7 4.4 0.6 1.3 650 23.7 15.9 0.67 0.56 24.4 40.3 -
900 19.0 1.65 13.4 89.6 3.39 2.3 750 24.0 17.3 0.72 0.59 24.9 38.8 -
6.7 1.1 2.6 700 19.2 1.74 13.3 95.4 3.23 2.8 5.8 0.9 2.1 650 23.8 15.9 0.67 0.54 24.5 41.7 -
900 19.6 1.67 13.9 90.2 3.44 2.4 750 24.4 17.3 0.71 0.57 25.1 40.7 -
    40 3.7 0.3 0.8 700 19.9 1.60 14.4 96.3 3.64 2.8     40 3.0 0.2 0.5 650 24.4 16.1 0.66 0.67 25.5 34.4 -
900 20.5 1.61 15.0 91.1 3.73 2.4 750 24.9 17.6 0.71 0.70 26.1 33.7 -
5.2 0.7 1.5 700 21.4 1.66 15.8 98.4 3.78 2.9 4.4 0.6 1.3 650 24.7 16.2 0.66 0.64 25.7 36.7 -
900 22.2 1.66 16.5 92.8 3.91 2.5 750 25.1 17.7 0.70 0.67 26.2 35.6 -
6.7 1.1 2.5 700 22.1 1.67 16.4 99.3 3.88 3.0 5.8 0.9 2.0 650 24.9 16.2 0.65 0.62 25.8 38.1 -
900 22.9 1.69 17.2 93.6 3.98 2.6 750 25.4 17.7 0.70 0.65 26.4 37.2 -
    50 3.7 0.3 0.7 700 22.7 1.64 17.1 100.0 4.06 3.1     50 3.0 0.2 0.5 650 25.0 15.3 0.61 0.85 26.7 27.9 -
900 23.4 1.64 17.8 94.1 4.19 2.8 750 25.8 18.0 0.70 0.89 27.6 27.6 -
5.2 0.6 1.5 700 24.4 1.69 18.7 102.3 4.24 3.3 4.4 0.5 1.2 650 25.5 15.3 0.60 0.74 26.8 33.0 -
900 25.4 1.68 19.6 96.1 4.43 2.9 750 26.3 18.1 0.69 0.77 27.7 32.4 -
6.7 1.1 2.5 700 25.4 1.70 19.6 103.6 4.37 3.4 5.8 0.9 2.0 650 25.7 15.3 0.60 0.69 26.8 35.2 -
900 26.2 1.70 20.4 97.0 4.52 3.0 750 26.5 18.1 0.68 0.73 27.7 34.5 -
    60 3.7 0.3 0.7 700 25.2 1.68 19.4 103.3 4.39 2.9     60 3.0 0.2 0.5 650 23.6 15.0 0.64 0.99 25.9 22.8 1.3
900 26.1 1.67 20.4 96.8 4.58 2.5 750 24.4 17.7 0.73 1.03 26.7 22.5 1.5
5.2 0.6 1.4 700 27.2 1.72 21.4 106.0 4.64 3.0 4.4 0.5 1.2 650 24.0 15.1 0.63 0.88 25.9 26.1 1.2
900 28.3 1.70 22.5 99.1 4.88 2.6 750 24.8 17.8 0.72 0.92 26.7 25.7 1.4
6.7 1.0 2.4 700 28.4 1.74 22.5 107.6 4.79 3.2 5.8 0.8 1.9 650 24.3 15.2 0.62 0.83 26.0 27.8 1.1
900 29.4 1.72 23.5 100.2 5.02 2.7 750 25.0 17.9 0.71 0.87 26.8 27.4 1.3
    70 3.7 0.3 0.7 700 27.7 1.72 21.8 106.6 4.72 3.4     70 3.0 0.2 0.5 650 22.3 14.8 0.66 1.12 25.1 18.9 2.2
900 30.5 1.72 24.6 101.4 5.20 3.0 750 22.9 16.5 0.72 1.18 25.8 18.5 2.3
5.2 0.6 1.4 700 30.0 1.75 24.1 109.7 5.03 3.6 4.4 0.5 1.2 650 22.5 14.9 0.66 1.02 24.9 21.1 2.0
900 31.2 1.72 25.4 102.1 5.32 3.2 750 23.2 17.6 0.76 1.06 25.8 20.8 2.2
6.7 1.0 2.3 700 31.4 1.77 25.4 111.6 5.20 3.8 5.8 0.8 1.8 650 22.9 15.0 0.66 0.97 25.1 22.5 1.8
900 32.6 1.73 26.7 103.5 5.52 3.5 750 23.6 17.6 0.75 1.01 25.9 22.3 2.0
    80 3.7 0.3 0.7 700 29.7 1.77 23.6 109.2 4.91 4.2     80 3.0 0.2 0.4 650 20.8 13.7 0.66 1.30 24.2 15.3 2.3
900 30.8 1.74 24.9 101.7 5.19 3.7 750 21.5 16.1 0.75 1.35 25.1 15.1 2.6
5.2 0.6 1.3 700 32.2 1.79 26.1 112.6 5.27 4.4 4.4 0.5 1.1 650 20.9 13.9 0.66 1.20 24.0 16.6 2.0
900 33.5 1.74 27.6 104.5 5.63 3.9 750 21.5 16.3 0.76 1.25 24.8 16.4 2.4
6.7 1.0 2.2 700 33.8 1.81 27.7 114.8 5.48 4.6 5.8 0.8 1.8 650 21.4 14.0 0.65 1.15 24.3 17.7 1.8
900 35.2 1.76 29.2 106.2 5.86 4.1 750 22.1 16.4 0.75 1.20 25.1 17.5 2.2
    90 3.7 0.3 0.6 700 31.6 1.82 25.4 111.8 5.09 5.1     90 3.0 0.2 0.4 650 19.3 12.7 0.66 1.47 23.4 12.6 3.7
900 32.9 1.78 26.8 103.8 5.41 4.6 750 19.9 14.9 0.75 1.52 24.2 12.5 4.0
5.2 0.6 1.3 700 34.4 1.83 28.1 115.5 5.51 5.4 4.4 0.5 1.1 650 19.3 12.8 0.66 1.39 23.1 13.2 3.3
900 35.8 1.77 29.8 106.8 5.93 4.8 750 19.9 15.1 0.76 1.44 23.8 13.1 3.8
6.7 0.9 2.2 700 36.3 1.85 30.0 118.0 5.75 5.6 5.8 0.7 1.7 650 19.8 14.1 0.71 1.37 23.6 13.8 3.0
900 37.8 1.79 31.7 108.9 6.19 5.0 750 20.5 15.2 0.74 1.39 24.2 14.0 3.5
    100 3.7 0.3 0.6               Operation not recommended     100 3.0 0.2 0.4 650 17.8 12.0 0.67 1.68 22.7 10.1 5.1
750 18.4 14.1 0.77 1.75 23.5 10.0 5.7
5.2 0.5 1.2 4.4 0.4 1.0 650 17.7 12.2 0.69 1.64 22.4 10.3 4.7
750 18.2 14.3 0.78 1.70 23.2 10.2 5.3
6.7 0.9 2.1 5.8 0.7 1.7 650 18.4 12.3 0.67 1.58 22.9 11.1 4.3
750 18.9 14.5 0.77 1.65 23.6 10.9 4.9
    110 3.7 0.3 0.6     110 3.0 0.2 0.4 650 16.3 11.4 0.70 1.89 22.0 8.2 7.3
750 16.8 13.3 0.79 1.97 22.7 8.1 7.8
5.2 0.5 1.2 4.4 0.4 1.0 650 16.1 11.5 0.72 1.88 21.7 8.1 6.8
750 16.6 13.5 0.81 1.96 22.5 8.1 7.5
6.7 0.9 2.0 5.8 0.7 1.6 650 16.9 11.7 0.70 1.82 22.3 8.8 6.2
750 17.3 13.8 0.79 1.90 23.0 8.7 7.0
    120 3.7 0.2 0.6     120 3.0 0.2 0.4 650 14.2 12.3 0.86 2.32 21.4 5.8 10.4
750 14.5 13.4 0.92 2.38 21.9 5.8 10.9
5.2 0.5 1.2 4.4 0.4 1.0 650 14.4 12.4 0.86 2.19 21.2 6.2 9.3
750 14.6 13.4 0.92 2.25 21.6 6.2 10.0
6.7 0.8 1.9 5.8 0.7 1.5 650 14.5 12.4 0.85 2.12 21.1 6.5 8.0
750 14.8 13.4 0.91 2.19 21.6 6.4 9.1
NVZ042 - 100% Full Load
  EWT °F   Flow gpm WPD HEATING - EAT 70°F   EWT °F   Flow gpm WPD COOLING - EAT 80/67 °F
PSI FT Airflow cfm HC MBtuh Power kW HE MBtuh LAT °F COP HWC MBtuh PSI FT Airflow cfm TC MBtuh SC MBtuh S/T Ratio Power kW HR MBtuh EER HWC MBtuh
  20 9.0 1.9 4.3 Operation not recommended   20 6.0 0.9 2.2   Operation not recommended
12.0 3.5 8.1 8.5 1.6 3.8
15.0 5.0 11.6 1600 36.8 3.84 23.7 91.3 2.81 3.5 11.0 2.5 5.7
1800 37.4 3.84 24.3 89.2 2.85 3.1
    30 9.0 1.8 4.2 1600 37.8 3.68 25.3 91.9 3.01 3.5     30 6.0 0.9 2.1 1200 38.7 24.1 0.62 1.40 43.5 27.6 -
1800 39.1 3.74 26.4 90.1 3.07 3.2 1400 39.4 26.5 0.67 1.46 44.4 27.0 -
12.0 3.4 7.9 1600 40.9 3.85 27.7 93.7 3.11 3.7 8.5 1.6 3.7 1200 39.2 24.3 0.62 1.34 43.8 29.4 -
1800 42.1 3.88 28.9 91.7 3.19 3.2 1400 39.9 26.6 0.67 1.41 44.7 28.3 -
15.0 4.9 11.3 1600 42.7 3.93 29.3 94.7 3.18 3.9 11.0 2.4 5.5 1200 39.4 24.3 0.62 1.30 43.9 30.4 -
1800 43.4 3.93 30.0 92.3 3.24 3.4 1400 40.4 26.6 0.66 1.36 45.0 29.7 -
    40 9.0 1.8 4.1 1600 43.0 3.81 30.0 94.9 3.31 3.8     40 6.0 0.9 2.0 1200 42.3 28.0 0.66 1.61 47.8 26.2 -
1800 44.4 3.84 31.3 92.8 3.39 3.5 1400 43.1 30.6 0.71 1.68 48.9 25.7 -
12.0 3.3 7.6 1600 46.4 3.96 32.9 96.8 3.44 4.2 8.5 1.5 3.6 1200 42.8 28.3 0.66 1.53 48.0 27.9 -
1800 48.0 3.96 34.5 94.7 3.56 3.7 1400 43.6 30.9 0.71 1.61 49.1 27.1 -
15.0 4.7 11.0 1600 47.9 3.98 34.3 97.7 3.53 4.4 11.0 2.3 5.3 1200 43.1 28.3 0.66 1.49 48.2 29.0 -
1800 49.6 4.01 35.9 95.5 3.62 3.9 1400 44.1 30.9 0.70 1.56 49.4 28.4 -
    50 9.0 1.7 3.9 1600 48.2 3.94 34.8 97.9 3.59 4.4     50 6.0 0.9 2.0 1200 45.1 29.6 0.66 2.04 52.1 22.1 -
1800 49.7 3.94 36.3 95.6 3.70 4.0 1400 46.5 35.0 0.75 2.13 53.8 21.9 -
12.0 3.2 7.4 1600 51.9 4.06 38.1 100.1 3.75 4.8 8.5 1.5 3.5 1200 46.1 29.8 0.65 1.77 52.1 26.1 -
1800 53.9 4.04 40.2 97.7 3.91 4.4 1400 47.5 35.1 0.74 1.85 53.8 25.6 -
15.0 4.6 10.6 1600 53.9 4.09 40.0 101.2 3.86 5.1 11.0 2.2 5.2 1200 46.4 29.8 0.64 1.66 52.1 27.9 -
1800 55.7 4.09 41.7 98.7 3.99 4.6 1400 47.8 35.1 0.73 1.75 53.8 27.3 -
    60 9.0 1.7 3.8 1600 53.3 4.09 39.4 100.8 3.82 5.2     60 6.0 0.8 1.9 1200 43.4 28.8 0.66 2.25 51.1 19.3 2.6
1800 55.2 4.06 41.4 98.4 3.98 4.7 1400 44.7 34.0 0.76 2.35 52.8 19.0 2.7
12.0 3.1 7.2 1600 57.7 4.19 43.4 103.4 4.04 5.6 8.5 1.4 3.3 1200 44.1 29.0 0.66 2.00 50.9 22.1 2.4
1800 59.9 4.14 45.8 100.8 4.24 5.1 1400 45.5 34.2 0.75 2.09 52.6 21.8 2.6
15.0 4.4 10.3 1600 60.1 4.23 45.7 104.8 4.17 6.0 11.0 2.2 5.0 1200 44.6 29.1 0.65 1.90 51.1 23.5 2.2
1800 62.3 4.18 48.0 102.0 4.37 5.4 1400 46.0 34.3 0.75 1.98 52.7 23.2 2.4
    70 9.0 1.6 3.7 1600 58.4 4.24 44.0 103.8 4.04 6.0     70 6.0 0.8 1.8 1200 41.6 28.0 0.67 2.46 50.0 16.9 3.4
1800 65.4 4.20 51.1 103.6 4.56 5.5 1400 44.0 33.1 0.75 2.42 52.3 18.2 3.6
12.0 3.0 6.9 1600 63.4 4.31 48.7 106.7 4.31 6.5 8.5 1.4 3.2 1200 42.1 28.3 0.67 2.23 49.7 18.9 3.1
1800 65.9 4.24 51.4 103.9 4.56 6.0 1400 43.4 33.3 0.77 2.33 51.3 18.7 3.4
15.0 4.3 9.9 1600 63.7 4.28 49.1 106.9 4.36 6.9 11.0 2.5 4.9 1200 42.8 28.4 0.66 2.13 50.0 20.1 2.8
1800 68.8 4.26 54.3 105.4 4.73 7.2 1400 44.1 33.4 0.76 2.21 51.6 20.0 3.2
    80 9.0 1.5 3.6 1600 61.8 4.38 46.8 105.8 4.13 7.1     80 6.0 0.8 1.8 1200 38.4 27.1 0.70 2.73 47.7 14.1 4.5
1800 64.2 4.31 49.5 103.0 4.37 6.5 1400 39.6 31.8 0.80 2.85 49.3 13.9 4.8
12.0 2.9 6.7 1600 67.1 4.43 52.0 108.8 4.44 7.6 8.5 1.4 3.1 1200 38.6 27.4 0.71 2.53 47.3 15.2 4.1
1800 69.8 4.32 55.1 105.9 4.73 7.0 1400 39.8 32.2 0.81 2.63 48.8 15.1 4.4
15.0 4.2 9.6 1600 70.5 4.48 55.2 110.8 4.61 8.1 11.0 2.0 4.7 1200 39.5 27.6 0.70 2.42 47.8 16.3 3.8
1800 73.4 4.36 58.5 107.7 4.93 7.5 1400 40.7 32.4 0.80 2.53 49.3 16.1 4.2
    90 9.0 1.5 3.4 1600 65.2 4.53 49.7 107.7 4.21 8.4     90 6.0 0.7 1.7 1200 35.2 26.1 0.74 2.99 45.4 11.8 6.0
1800 67.7 4.44 52.6 104.8 4.48 7.7 1400 36.3 30.7 0.84 3.12 46.9 11.7 6.3
12.0 2.8 6.5 1600 70.9 4.56 55.3 111.0 4.55 8.9 8.5 1.3 3.0 1200 35.2 26.4 0.75 2.84 44.9 12.4 5.3
1800 73.8 4.41 58.7 108.0 4.90 8.2 1400 36.2 31.1 0.86 2.94 46.2 12.3 5.8
15.0 4.0 9.3 1600 74.8 4.61 59.0 113.3 4.75 9.5 11.0 2.0 4.5 1200 36.1 29.2 0.81 2.79 45.6 12.9 5.0
1800 77.9 4.46 62.7 110.1 5.12 8.7 1400 37.3 31.4 0.84 2.84 47.0 13.1 6.3
    100 9.0 1.4 3.3               Operation not recommended     100 6.0 0.7 1.7 1200 32.6 24.4 0.75 3.32 43.9 9.8 7.0
1400 33.6 28.7 0.85 3.46 45.4 9.7 7.5
12.0 2.7 6.2 8.5 1.3 2.9 1200 32.4 24.7 0.76 3.23 43.4 10.0 6.7
1400 33.4 29.1 0.87 3.36 44.8 9.9 7.3
15.0 3.9 8.9 11.0 1.9 4.4 1200 33.6 25.1 0.75 3.11 44.2 10.8 6.3
1400 34.6 29.5 0.85 3.25 45.6 10.6 7.1
    110 9.0 1.4 3.2     110 6.0 0.7 1.6 1200 30.0 22.7 0.76 3.64 42.4 8.2 9.0
1400 30.8 26.7 0.87 3.79 43.7 8.1 9.8
12.0 2.6 6.0 8.5 1.2 2.8 1200 29.5 23.0 0.78 3.62 41.9 8.2 8.6
1400 30.5 27.1 0.89 3.77 43.4 8.1 9.4
15.0 3.7 8.6 11.0 1.8 4.2 1200 30.9 23.4 0.76 3.51 42.9 8.8 8.2
1400 31.8 27.5 0.86 3.66 44.3 8.7 9.2
    120 9.0 1.3 3.1     120 6.0 0.7 1.5 1200 26.7 23.9 0.90 4.35 41.5 6.1 11.9
1400 27.2 26.1 0.96 4.45 42.4 6.1 12.4
12.0 2.5 5.8 8.5 1.2 2.7 1200 27.0 24.1 0.89 4.11 41.0 6.6 11.1
1400 27.5 26.2 0.95 4.21 41.9 6.5 12.0
15.0 3.6 8.2 11.0 1.7 4.0 1200 27.2 24.1 0.89 3.97 40.8 6.8 10.2
1400 27.8 26.2 0.94 4.10 41.8 6.8 11.4
NVZ050 - 50% Part Load
  EWT °F   Flow gpm WPD HEATING - EAT 70°F   EWT °F   Flow gpm WPD COOLING - EAT 80/67 °F
PSI FT Airflow cfm HC MBtuh Power kW HE MBtuh LAT °F COP HWC MBtuh PSI FT Airflow cfm TC MBtuh SC MBtuh S/T Ratio Power kW HR MBtuh EER HWC MBtuh
  20 3.7 0.1 0.3 Operation not recommended   20 3.2 0.1 0.3   Operation not recommended
5.1 0.6 1.4 4.6 0.5 1.1
7.5 1.2 2.7 850 21.5 2.29 14.0 93.7 2.78 3.9 6.0 0.8 1.9
980 21.6 2.20 14.1 90.4 2.88 3.7
    30 3.7 0.1 0.3 850 23.8 2.32 15.0 95.0 2.90 4.0     30 3.2 0.1 0.3 750 23.2 15.5 0.67 0.64 24.3 34.6 -
980 24.7 2.35 15.7 92.4 2.96 3.6 850 23.7 17.0 0.72 0.67 24.8 33.8 -
5.1 0.6 1.3 850 23.7 2.35 14.8 94.8 2.84 4.1 4.6 0.5 1.1 750 23.6 15.7 0.66 0.61 24.5 36.8 -
980 24.6 2.38 15.5 92.3 2.90 3.7 850 23.9 17.1 0.72 0.64 25.0 35.5 -
7.5 1.1 2.6 850 25.3 2.48 16.1 96.8 2.91 4.1 6.0 0.8 1.8 750 23.7 15.7 0.66 0.59 24.6 38.2 -
980 25.4 2.38 16.3 93.1 3.00 3.5 850 24.3 17.1 0.71 0.62 25.2 37.3 -
    40 3.7 0.1 0.3 850 28.2 2.39 19.1 99.7 3.35 4.2     40 3.2 0.1 0.3 750 27.0 18.4 0.68 0.86 28.6 30.0 -
980 29.1 2.40 19.9 96.5 3.43 3.8 850 27.5 20.1 0.73 0.89 29.3 29.4 -
5.1 0.6 1.3 850 28.4 2.42 19.2 99.9 3.32 4.3 4.6 0.4 1.0 750 27.3 18.6 0.68 0.81 28.8 32.0 -
980 29.2 2.43 19.9 96.7 3.40 3.9 850 27.8 20.3 0.73 0.85 29.4 31.1 -
7.5 1.1 2.5 850 29.4 2.43 20.0 100.9 3.41 4.4 6.0 0.8 1.8 750 27.5 18.6 0.67 0.79 28.9 33.2 -
980 30.2 2.44 20.8 97.5 3.50 4.0 850 28.1 20.3 0.72 0.83 29.6 32.5 -
    50 3.7 0.1 0.2 850 32.6 2.45 23.2 104.4 3.77 4.5     50 3.2 0.1 0.2 750 31.0 20.5 0.66 1.04 33.0 28.4 -
980 33.5 2.45 24.1 100.7 3.88 4.2 850 31.9 23.2 0.73 1.10 34.1 27.7 -
5.1 0.5 1.2 850 33.1 2.50 23.6 105.0 3.76 4.7 4.6 0.4 1.0 750 31.0 20.6 0.67 1.00 33.0 29.5 -
980 33.9 2.48 24.3 101.0 3.87 4.3 850 31.9 23.4 0.73 1.05 34.0 29.0 -
7.5 1.1 2.5 850 34.1 2.52 24.5 106.0 3.85 4.8 6.0 0.7 1.7 750 31.1 20.6 0.66 0.98 33.0 30.2 -
980 34.9 2.50 25.3 101.9 3.96 4.4 850 32.0 23.4 0.73 1.03 34.0 29.6 -
    60 3.7 0.1 0.2 850 36.4 2.53 26.6 108.4 4.08 4.3     60 3.2 0.1 0.2 750 30.0 20.0 0.67 1.26 32.9 22.7 2.4
980 37.2 2.51 27.5 104.0 4.21 3.9 850 30.9 22.6 0.73 1.32 34.0 22.3 2.6
5.1 0.5 1.2 850 37.5 2.57 27.6 109.6 4.14 4.4 4.6 0.4 1.0 750 30.2 20.2 0.67 1.22 32.9 23.5 2.3
980 38.1 2.54 28.3 104.9 4.27 4.0 850 31.1 22.8 0.73 1.27 33.9 23.2 2.5
7.5 1.0 2.4 850 38.4 2.60 28.4 110.5 4.20 4.6 6.0 0.7 1.7 750 30.3 20.2 0.67 1.20 32.9 24.1 2.2
980 39.0 2.56 29.1 105.7 4.33 4.1 850 31.2 22.8 0.73 1.25 34.0 23.8 2.4
    70 3.7 0.1 0.2 850 40.1 2.61 30.0 112.4 4.38 4.8     70 3.2 0.1 0.2 750 29.1 19.5 0.67 1.48 32.8 18.7 3.3
980 39.4 2.57 29.3 106.0 4.34 4.4 850 29.6 22.1 0.74 1.66 33.9 17.0 3.4
5.1 0.5 1.2 850 41.8 2.65 31.5 114.2 4.49 5.0 4.6 0.4 0.9 750 29.3 19.7 0.67 1.44 32.8 19.4 3.1
980 42.3 2.59 32.2 108.8 4.64 4.6 850 30.2 22.2 0.74 1.50 33.9 19.1 3.3
7.5 1.0 2.3 850 42.6 2.68 32.2 115.1 4.53 5.2 6.0 0.7 1.6 750 29.4 19.8 0.67 1.41 32.8 19.9 2.9
980 43.1 2.62 32.9 109.5 4.68 4.8 850 30.3 22.3 0.73 1.47 33.9 19.7 3.1
    80 3.7 0.1 0.2 850 43.5 2.68 30.1 112.7 4.29 5.7     80 3.2 0.1 0.2 750 27.2 19.5 0.68 1.75 31.9 14.8 3.4
980 43.9 2.62 30.6 107.4 4.43 5.2 850 28.0 21.7 0.74 1.81 32.9 14.7 3.7
5.1 0.5 1.1 850 46.0 2.72 32.2 115.2 4.46 5.9 4.6 0.4 0.9 750 27.5 19.7 0.68 1.71 32.0 15.3 3.1
980 46.2 2.64 32.6 109.4 4.62 5.4 850 28.3 22.0 0.74 1.77 33.0 15.2 3.5
7.5 1.0 2.2 850 46.5 2.76 32.5 115.7 4.45 6.1 6.0 0.7 1.6 750 27.6 19.8 0.68 1.68 32.1 15.7 2.9
980 46.7 2.68 33.0 109.8 4.60 5.6 850 28.5 22.2 0.74 1.74 33.1 15.6 3.3
    90 3.7 0.1 0.2 850 46.9 2.75 30.2 113.1 4.21 6.6     90 3.2 0.1 0.2 750 25.4 19.4 0.69 2.02 31.0 11.9 4.8
980 47.0 2.68 30.5 107.5 4.33 6.1 850 26.1 21.6 0.74 2.08 32.0 12.0 5.1
5.1 0.5 1.1 850 50.1 2.80 32.7 116.0 4.42 6.9 4.6 0.4 0.9 750 25.6 19.6 0.69 1.98 31.2 12.4 4.4
980 50.1 2.70 33.0 109.9 4.59 6.3 850 26.4 21.9 0.75 2.04 32.1 12.3 4.9
7.5 0.9 2.2 850 50.4 2.84 32.8 116.3 4.38 7.1 6.0 0.7 1.5 750 25.9 19.7 0.76 1.97 31.4 12.5 4.1
980 50.3 2.74 33.1 110.1 4.54 6.5 850 26.7 22.1 0.74 2.01 32.3 12.6 4.6
    100 3.7 0.1 0.2               Operation not recommended     100 3.2 0.1 0.2 750 24.1 18.5 0.73 2.32 30.9 9.9 6.2
850 24.8 20.4 0.78 2.38 31.7 9.9 6.8
5.1 0.4 1.0 4.6 0.4 0.8 750 24.4 18.7 0.72 2.29 31.0 10.2 5.8
850 25.1 20.7 0.78 2.35 31.9 10.2 6.4
7.5 0.9 2.1 6.0 0.6 1.5 750 24.6 18.9 0.73 2.26 31.1 10.4 5.4
850 25.4 20.9 0.78 2.31 32.1 10.5 6.0
    110 3.7 0.1 0.2     110 3.2 0.1 0.2 750 22.8 17.5 0.77 2.62 30.7 8.3 8.4
850 23.5 19.3 0.82 2.67 31.5 8.4 8.9
5.1 0.4 1.0 4.6 0.3 0.8 750 23.1 17.7 0.77 2.60 30.9 8.5 7.9
850 23.8 19.5 0.82 2.65 31.7 8.6 8.6
7.5 0.9 2.0 6.0 0.6 1.4 750 23.4 18.0 0.77 2.56 31.0 8.7 7.3
850 24.2 19.7 0.82 2.61 31.9 8.8 8.1
    120 3.7 0.1 0.2     120 3.2 0.1 0.2 750 21.4 17.4 0.81 3.18 31.3 6.4 11.5
850 21.9 18.9 0.87 3.25 32.0 6.4 12.0
5.1 0.4 1.0 4.6 0.3 0.8 750 21.7 17.5 0.81 3.01 30.9 6.9 10.4
850 22.1 19.0 0.86 3.08 31.6 6.8 11.1
7.5 0.8 1.9 6.0 0.6 1.3 750 21.9 17.5 0.80 2.91 30.8 7.2 9.1
850 22.4 19.0 0.85 3.00 31.5 7.1 10.2
NVZ050 - 100% Full Load
  EWT °F   Flow gpm WPD HEATING - EAT 70°F   EWT °F   Flow gpm WPD COOLING - EAT 80/67 °F
PSI FT Airflow cfm HC MBtuh Power kW HE MBtuh LAT °F COP HWC MBtuh PSI FT Airflow cfm TC MBtuh SC MBtuh S/T Ratio Power kW HR MBtuh EER HWC MBtuh
  20 9.0 2.0 4.6 Operation not recommended   20 9.0 0.8 1.9   Operation not recommended
13.5 4.6 10.5 11.5 2.0 4.6
18.0 7.2 16.7 1800 47.3 5.16 29.6 94.3 2.68 5.5 14.0 3.2 7.3
2200 49.6 5.21 31.8 90.9 2.79 5.0
    30 9.0 1.9 4.5 1800 51.5 4.97 34.5 96.5 3.03 5.6     30 9.0 0.8 1.8 1400 46.9 29.7 0.63 1.88 53.4 25.0 -
2200 52.7 5.23 34.8 92.2 2.95 5.0 1600 47.8 32.5 0.68 1.96 54.5 24.4 -
13.5 4.4 10.2 1800 55.1 5.02 38.0 98.3 3.22 5.7 11.5 1.9 4.5 1400 47.6 29.9 0.63 1.79 53.7 26.6 -
2200 56.6 5.34 38.4 93.8 3.11 5.2 1600 48.4 32.7 0.68 1.88 54.8 25.7 -
18.0 7.0 16.2 1800 54.5 5.34 36.3 98.0 2.99 5.9 14.0 3.1 7.1 1400 47.8 29.9 0.63 1.73 53.7 27.6 -
2200 57.2 5.39 38.8 94.1 3.11 5.3 1600 49.0 32.7 0.67 1.82 55.2 26.9 -
    40 9.0 1.9 4.3 1800 58.7 5.23 40.8 100.2 3.29 6.0     40 9.0 0.8 1.8 1400 51.0 33.0 0.65 2.15 58.4 23.8 -
2200 60.0 5.44 41.4 95.2 3.23 5.6 1600 52.0 36.1 0.69 2.24 59.7 23.3 -
13.5 4.3 9.9 1800 62.4 5.31 44.2 102.1 3.44 6.3 11.5 1.9 4.3 1400 51.6 33.3 0.65 2.04 58.6 25.3 -
2200 63.8 5.54 44.9 96.8 3.38 5.8 1600 52.6 36.4 0.69 2.14 59.9 24.6 -
18.0 6.8 15.7 1800 63.3 5.40 44.9 102.6 3.44 6.5 14.0 3.0 6.9 1400 52.0 33.3 0.64 1.98 58.8 26.3 -
2200 64.8 5.59 45.7 97.3 3.39 5.9 1600 53.2 36.4 0.68 2.07 60.3 25.7 -
    50 9.0 1.8 4.2 1800 65.8 5.48 47.1 103.9 3.52 6.8     50 9.0 0.7 1.7 1400 55.2 36.2 0.66 2.27 62.9 24.3 -
2200 67.2 5.65 47.9 98.3 3.48 6.3 1600 56.3 39.4 0.70 2.41 64.5 23.3 -
13.5 4.2 9.6 1800 69.6 5.59 50.6 105.8 3.65 7.0 11.5 1.8 4.2 1400 55.7 36.5 0.66 2.22 63.3 25.1 -
2200 71.0 5.73 51.5 99.9 3.63 6.4 1600 56.8 39.8 0.70 2.36 64.9 24.1 -
18.0 6.6 15.2 1800 70.8 5.65 51.5 106.4 3.67 7.2 14.0 2.9 6.7 1400 56.3 36.9 0.66 2.18 63.7 25.8 1.7
2200 72.3 5.79 52.5 100.4 3.66 6.6 1600 57.4 40.1 0.70 2.32 65.3 24.7 1.9
    60 9.0 1.8 4.1 1800 74.2 5.77 54.5 108.2 3.76 7.6     60 9.0 0.7 1.7 1400 52.7 35.4 0.67 2.54 61.3 20.8 3.0
2200 75.8 5.87 55.8 101.9 3.78 7.0 1600 54.0 38.5 0.71 2.70 63.2 20.0 3.1
13.5 4.0 9.3 1800 77.6 5.87 57.6 109.9 3.87 7.8 11.5 1.8 4.1 1400 53.2 35.7 0.67 2.49 61.7 21.4 2.8
2200 79.3 5.95 59.0 103.4 3.91 7.2 1600 54.6 38.8 0.71 2.64 63.6 20.7 3.0
18.0 6.4 14.7 1800 79.3 5.94 59.0 110.8 3.91 8.1 14.0 2.8 6.5 1400 53.7 36.1 0.67 2.44 62.1 22.0 2.6
2200 81.1 6.01 60.6 104.1 3.96 7.4 1600 55.1 39.2 0.71 2.60 64.0 21.2 2.8
    70 9.0 1.7 3.9 1800 82.5 6.06 61.9 112.5 3.99 8.5     70 9.0 1.6 1.6 1400 50.2 34.6 0.69 2.81 59.8 17.9 3.8
2200 83.4 6.10 62.6 105.1 4.01 7.9 1600 52.3 38.2 0.73 3.08 62.8 17.0 4.0
13.5 3.9 9.0 1800 85.6 6.15 64.6 114.0 4.08 8.8 11.5 2.6 3.9 1400 50.7 34.9 0.69 2.75 60.1 18.4 3.5
2200 87.5 6.16 66.5 106.8 4.16 8.1 1600 52.3 37.9 0.72 2.93 62.3 17.9 3.8
18.0 6.2 14.3 1800 87.7 6.22 66.5 115.1 4.13 9.1 14.0 3.6 6.2 1400 51.2 35.2 0.69 2.71 60.4 18.9 3.2
2200 89.8 6.22 68.6 107.8 4.23 8.3 1600 52.8 38.3 0.73 2.88 62.6 18.3 3.6
    80 9.0 1.6 3.8 1800 88.0 6.19 66.9 115.3 4.17 9.6     80 9.0 0.7 1.6 1400 47.2 33.7 0.71 3.22 58.2 14.7 4.9
2200 90.0 6.15 69.0 107.9 4.29 8.9 1600 48.9 36.6 0.75 3.43 60.7 14.3 5.2
13.5 3.8 8.7 1800 90.1 6.27 68.7 116.3 4.21 9.9 11.5 1.6 3.8 1400 47.7 34.0 0.71 3.16 58.5 15.1 4.5
2200 92.2 6.20 71.1 108.8 4.36 9.1 1600 49.4 37.0 0.75 3.36 60.9 14.7 4.8
18.0 6.0 13.8 1800 92.8 6.34 71.2 117.8 4.29 10.2 14.0 2.6 6.0 1400 48.2 34.4 0.71 3.10 58.7 15.5 4.2
2200 95.2 6.27 73.8 110.0 4.45 9.4 1600 50.0 37.4 0.75 3.31 61.2 15.1 4.6
    90 9.0 1.6 3.7 1800 93.4 6.31 71.9 118.1 4.34 10.7     90 9.0 0.7 1.5 1400 44.2 32.9 0.74 3.63 56.6 12.2 6.4
2200 95.7 6.22 74.5 110.3 4.51 9.9 1600 46.2 35.7 0.77 3.87 59.4 11.9 6.7
13.5 3.6 8.4 1800 94.7 6.38 72.9 118.7 4.35 11.1 11.5 1.6 3.7 1400 44.7 33.1 0.74 3.56 56.9 12.6 5.7
2200 97.0 6.24 75.7 110.8 4.55 10.2 1600 46.6 36.1 0.77 3.79 59.5 12.3 6.2
18.0 5.7 13.3 1800 97.9 6.46 75.9 120.4 4.44 11.4 14.0 2.5 5.8 1400 45.7 34.1 0.75 3.65 58.2 12.5 5.4
2200 100.5 6.31 79.0 112.3 4.67 10.6 1600 47.1 36.4 0.77 3.73 59.8 12.6 6.5
    100 9.0 1.5 3.5               Operation not recommended     100 9.0 0.6 1.5 1400 41.3 31.9 0.77 4.13 55.4 10.0 8.1
1600 43.3 34.7 0.80 4.40 58.3 9.8 8.6
13.5 3.5 8.1 11.5 1.5 3.5 1400 41.7 32.2 0.77 4.05 55.5 10.3 7.8
1600 43.7 35.0 0.80 4.31 58.4 10.1 8.4
18.0 5.5 12.8 14.0 2.4 5.6 1400 42.1 32.6 0.77 3.97 55.7 10.6 7.4
1600 44.2 35.4 0.80 4.24 58.6 10.4 8.2
    110 9.0 1.5 3.4     110 9.0 0.6 1.4 1400 38.3 30.9 0.81 4.63 54.1 8.3 10.1
1600 40.4 33.6 0.83 4.93 57.2 8.2 10.9
13.5 3.4 7.8 11.5 1.5 3.4 1400 38.8 31.2 0.81 4.53 54.2 8.6 9.7
1600 40.8 33.9 0.83 4.83 57.3 8.5 10.5
18.0 5.3 12.3 14.0 2.3 5.4 1400 39.1 31.6 0.81 4.45 54.3 8.8 9.3
1600 41.2 34.3 0.83 4.75 57.4 8.7 10.3
    120 9.0 1.4 3.3     120 9.0 0.6 1.3 1400 33.6 30.0 0.90 5.65 52.8 5.9 13.0
1600 34.3 32.8 0.96 5.78 54.0 5.9 13.5
13.5 3.2 7.5 11.5 1.4 3.3 1400 34.0 30.3 0.89 5.34 52.2 6.4 12.2
1600 34.6 32.9 0.95 5.48 53.3 6.3 13.1
18.0 5.1 11.8 14.0 2.2 5.2 1400 34.3 30.3 0.88 5.17 51.9 6.6 11.3
1600 35.0 32.9 0.94 5.33 53.2 6.6 12.5
3/27/2020

Compressor Section Wiring Schematics

Aurora Variable Speed Indoor Split WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 6 97P928-03A Compressor Section Wiring Schematics cont. Aurora Variable Speed Indoor Split WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 7 Notes

  1. Variable speed pump low voltage harness provided with Variable Speed Flow Center.
  2. Low voltage wiring CLASS 2.
  3. Communication cable routed through Ferrite Toroid four times.
  4. Compressor power cable routed through Ferrite Toroid three times.
  5. Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board are provided with Variable Speed Flow Center.
  6. Wiring harness supplied with valve.
 Legend
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 2 Factory Low voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 3 Factory Line voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 4 Field low voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 5 Field line voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 6 Optional block
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 7 DC Voltage PCB traces
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 8 Field Installed Item
Junction
Quick connect terminal
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 9 Wire nut
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 10 Field wire lug
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 11 Ground
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 12 Relay Contacts- N.O., N.C.
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 13 Fuse
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 14 Color identification tape on wire.
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 15 Thermistor
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 16 Light  emitting diode - Green
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 17 Relay coil
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 18 Capacitor w/ bleed resistor
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 19 Switch - Condensate overflow
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 20 Switch - High pressure
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 21 Switch - Low pressure
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 22 Current Transducer (CT)
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 23 Polarized connector
CC - Compressor Contactor CO - Condensate overflow sensor K5 - DHW pump relay K6 - Loop pump relay CR3 - PSC Fan Speed Relay CR4 - PSC Fan Power Relay CS - Compressor Solenoid F1, F2 - Fuses HE - Heater element HP - High pressure switch LP - Low pressure switch ER1 to ER4 - Aux heat stage relays PB1, PB2 - Power blocks PS - Power strip RV - Reversing Valve coil SW1 - DIP Switch - 5 position AXB SW1 - TEST MODE ABC Board SW2 - DIP Switch - 8 position ABC Board FP1, FP2 - Freeze Protection TS - Thermal limit switch SC - Start Contactor SR - Start Relay HWL - Hot water limit sensor WCL - Water Coil Limit Sensor
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 8WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 9Compressor Section Wiring Schematics cont. Aurora Variable Speed Indoor Split WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 10Compressor Section Wiring Schematics cont. Aurora Variable Speed Indoor Split WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 11
ABC SW2 Accessory Relay
DESCRIPTION SW2-4 SW2-5
Cycle with Blower ON ON
Cycle with Compressor OFF OFF
Water Valve Slow Opening ON OFF
Cycle with Comm. T-stat Hum Cmd OFF ON
AXB Accessory 2 DIP Seƫngs
SW1-4 SW1-5 DESCRIPTION
ON ON Cycles with Blower
OFF ON Cycles with CC first stage compressor or compressor spd 1-12
ON OFF Cycles with CC2 second stage of compressor or comp spd 7-12
OFF OFF Cycles with DH from ABC board
Aurora LED Flash Codes
Slow Flash 1 second on and 1 second off
Fast Flash 100 miilllliseconds on and 100 miilllliseconds off
Flash Code 100 millliiseconds on and 400 miilllliiseconds off wiith a 2 second pause before repeating
Fault LED (LED 1, Red) Random Start Delay (Alternating Colors)
Normal Mode OFF Status LED (LED1, Green) Fast Flash
Input Fault Lockout Flash Code 1 Configuration LED (LED 2, Yellow) Fast Flash
High Pressure Lockout Flash Code 2 Fault LED (LED 3, Red) Fast Flash
Low Pressure Lockout Flash Code 3 Configuration LED (LED 2, Yellow)
Freeze Protection- FP2 Flash Code 4 No Software Overide OFF
Freeze Protection - FP1 Flash Code 5 DIP Swiitch Overiide Slow Flash
Loss of Charge Flash Code 6 Status LED (LED 3, Green)
Condensate Overflow Lockout Flash Code 7 Normall Mode ON
Over/Under Volltage Shutdown Flash Code 8 Controll is Non - Functiional OFF
Future Use Flash Code 9 Test Mode Slow Flash
Lockout Actiive Fast Flash
Fault- FP1 and FP2 Sensor Error Flash Code 11 Dehumidifiication Mode Flash Code 2
Future Use Flash Code 12 Future Use Flash Code 3
Non-Criticall AXB Sensor Error Flash Code 13 Future Use Flash Code 4
Critical AXB Sensor Error Flash Code 14 Load Shed Flash Code 5
Alarm - Hot Water Flash Code 15 ESD Flash Code 6
Fault Variiable Speed Pump Flash Code 16 Future Use Flash Code 7
Future Use Flash Code 17 Fault LED (LED 1, Red) Cont.
Non-Criitiicall Communication Error Flash Code 18 Safe Mode - Ambiient Temp Sensor Flash Code 49
Fault - Critical Communication Error Flash Code 19 Fault - Diischarge Temperature Sensor Flash Code 51
Allarm - Low Loop Pressure Flash Code 21 Fault - Suction Pressure Sensor Flash Code 52
Fault - Communication ECM Fan Motor Error Flash Code 22 Faullt - Condensiing Pressure Sensor Flash Code 53
Alarm - Home Automation 1 Flash Code 23 Fault - Low Supply Voltage Flash Code 54
Allarm - Home Automation 2 Flash Code 24 Fault - Compressor Out of Envelope Flash Code 55
Fault - EEV Error Flash Code 25 Fault - Over Current Flash Code 56
Derate - Drive Temperature Flash Code 41 Fault - Over/Under Volltage Flash Code 57
Derate - High Diischarge Temperature Flash Code 42 Fault - Hiigh Drive Temperature Flash Code 58
Derate - Low Suction Temperature Flash Code 43 Fault - Drive Internal Error MOC/AOC Flash Code 59
Derate - Low Condensing Pressure Flash Code 44 Fault - Multiiple Safe Modes Flash Code 61
Derate - High Condensing Pressure Flash Code 45 EEV2 Fault - Loss of Charge Flash Code 71
Derate - Outer Power Liimiit Flash Code 46 EEV2 Safe Mode - Suc Temp Sensor Flash Code 72
Safe Mode - EEV (Indoor) Communication Flash Code 47 EEV2 Safe Mode - LAT Temp Sensor Flash Code 73
Safe Mode - EEV (Outdoor) Communicatiion Flash Code 48 EEV2 Safe Mode - Max Op Pressure Flash Code 74
EEV1 Fault - Loss of Charge Flash Code 75
EEV1Safe Mode - Suctiion Temp Sensor Flash Code 76
EEV1Safe Mode - LAT Temp Sensor Flash Code 77
EEV1 Safe Mode - Max Op Pressure Flash Code 78
Compressor Section Wiring Schematics cont. Aurora Variable Speed Indoor Split with UPC WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 12 Compressor Section Wiring Schematics cont. Aurora Variable Speed Indoor Split with UPC  Notes
  1. Variable speed pump low voltage harness provided with Variable Speed Flow Center.
  2. Low voltage wiring CLASS 2.
  3. Communication cable routed through Ferrite Toroid four times.
  4. Compressor power cable routed through Ferrite Toroid three times.
  5. Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board are provided with Variable Speed Flow Center.
  6. Wiring harness supplied with valve.
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 2 Factory Low voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 3 Factory Line voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 4 Field low voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 5 Field line voltage wiring
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 6 Optional block
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 7 DC Voltage PCB traces
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 8 Field Installed Item
Junction
Quick connect terminal
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 9 Wire nut
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 10 Field wire lug
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 11 Ground
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 12 Relay Contacts- N.O., N.C.
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 13 Fuse
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 14 Color identification tape on wire.
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 15 Thermistor
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 16 Light  emitting diode - Green
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 17 Relay coil
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 18 Capacitor w/ bleed resistor
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 19 Switch - Condensate overflow
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 20 Switch - High pressure
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 21 Switch - Low pressure
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 22 Current Transducer (CT)
WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Icon 23 Polarized connector
CC - Compressor Contactor CO - Condensate overflow sensor K5 - DHW pump relay K6 - Loop pump relay CR3 - PSC Fan Speed Relay CR4 - PSC Fan Power Relay CS - Compressor Solenoid F1, F2 - Fuses HE - Heater element HP - High pressure switch LP - Low pressure switch ER1 to ER4 - Aux heat stage relays PB1, PB2 - Power blocks PS - Power strip RV - Reversing Valve coil SW1 - DIP Switch - 5 position AXB SW1 - TEST MODE ABC Board SW2 - DIP Switch - 8 position ABC Board FP1, FP2 - Freeze Protection TS - Thermal limit switch SC - Start Contactor SR - Start Relay HWL - Hot water limit sensor WCL - Water Coil Limit Sensor

Air Handler Wiring Schematics

WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 15 Air Handler Wiring Schematics cont.

7 SeriesAir Handler Air Flow
Model Max ESP Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12
033 0.75 250 400 G 550 L 650 750 850 1000 1150 1250 H 1350 Aux 1450 1600
042 0.75 250 450 G 650 L 800 950 1050 1200 1350 1450 1600 H 1750 Aux 1850
050 0.75 300 550 G 800 L 1000 1150 1300 1450 1600 1750 1900 H 2050 Aux 2200
**VS Compressor Speed 1-2 3-4 5-6 7-8 9-10 11-12
** VS Compressor speed is given for the factory default cfm se ngs. When the cfm default se ngs are changed it will change the rela onship to the compressor speed that is shown in the table. In cooling mode compressor speeds 10-12 are only available when SuperBoost mode is selected at the thermostat. Factory se ngs are at recommended G, L , H and Aux posi ons "G" may be located anywhere within the air ow table. "L" seng should be located within the boldface CFM range "H" seng MUST be located within the shaded CFM range "Aux" seng MUST be equal to or greater than "H" seng CFM is controlled within 5% up to the maximum ESP Communicating Thermostat will connect to the COMM STAT (C R + -) power block PB3 in the air handler. A 4-conductor, 20AWG wire will need to connect from the TO ABC (C R + -) power block (PB2) in the Air Handler to the ABC P7(See detail ‘A’ on schematic) connection on the ABC board in the compressor section. Communicating Thermostat WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 16 Note: On the AID Tool Configure Aurora Screen, confirm the AHB is added and communicating. Notes 1 - To operate in 208V mode replace the blue transformer wire connected to PB1-L2 with red transformer wire. 2 - Low voltage wiring CLASS 2. 3 - DIP switch 1 on SW1 must be set in the OFF position. BANG OLUFSEN Beosound Theatre Soundbar-fig2Air Handler Wiring Schematics cont. WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 17
7 SeriesAir Handler Air Flow
Model Max ESP Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12
033 0.75 250 400 G 550 L 650 750 850 1000 1150 1250 H 1350 Aux 1450 1600
042 0.75 250 450 G 650 L 800 950 1050 1200 1350 1450 1600 H 1750 Aux 1850
050 0.75 300 550 G 800 L 1000 1150 1300 1450 1600 1750 1900 H 2050 Aux 2200
**VS Compressor Speed 1-2 3-4 5-6 7-8 9-10 11-12
11/29/2018

** VS Compressor speed is given for the factory default cfm sengs. When the cfm default sengs are changed it will change the relaonship to the compressor speed that is shown in the table. Incooling mode compressor speeds 10-12 are only available when SuperBoost mode is selected at the thermostat. Factory sengs are at recommended G, L , H and Aux posions "G" may be located anywhere within the airow table. "L" seng should be located within the boldface CFM range "H" seng MUST be located within the shaded CFM range "Aux" seng MUST be equal to or greater than "H" seng CFM is controlled within 5% up to the maximum ESP

Communicating Thermostat will connect to the COMM STAT (C R + -) power block PB3 in the air handler. A 4-conductor, 20AWG wire will need to connect from the TO ABC (C R + -) power block (PB2) in the Air Handler to the ABC P7(See detail ‘A’ on schematic) connection on the ABC board in the compressor section. Communicating Thermostat

WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 18 Note: On the AID Tool Configure Aurora Screen, confirm the AHB is added and communicating. Notes 1 - To operate in 208V mode replace the blue transformer wire connected to PB1-L2 with red transformer wire. 2 - Low voltage wiring CLASS 2. 3 - DIP switch 1 on SW1 must be set in the OFF position. BANG OLUFSEN Beosound Theatre Soundbar-fig2Dual Power Supply Connections If two separate circuits are used to supply power to the auxiliary heat kit, the Installer will need to verify that each leg of the auxiliary heat circuit breakers are wired from the power supply correctly in order for the electric heat kit to operate properly. This can be done by measuring the supply side voltage of the auxiliary heat circuit breakers. Put a voltmeter on the L2 side of Circuit Breaker One and on the L2 side of Circuit Breaker Two. The voltmeter should read approximately 0 volts. If the meter reads high voltage, the auxiliary heat breakers need to be rewired so that breakers in the auxiliary heat kit match the wiring of the Disconnect Panel breakers. Meaning, L1 and L2 from one breaker in the disconnect panel must L1 and L2 from one breaker in the disconnect panel must connect to L1 and L2 at one of the auxiliary heat circuit breakers and L1 and L2 from the other breaker in the disconnect panel must connect to L1 and L2 of the other auxiliary heat circuit breaker, making sure that the L1 and L2 from each disconnect breaker matches the L1 and L2 at each of the auxiliary heat breakers. WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 19
7 SeriesAir Handler Air Flow
Model Max ESP Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12
033 0.75 250 400 G 550 L 650 750 850 1000 1150 1250 H 1350 Aux 1450 1600
042 0.75 250 450 G 650 L 800 950 1050 1200 1350 1450 1600 H 1750 Aux 1850
050 0.75 300 550 G 800 L 1000 1150 1300 1450 1600 1750 1900 H 2050 Aux 2200
**VS Compressor Speed 1-2 3-4 5-6 7-8 9-10 11-12
11/29/2018

** VS Compressor speed is given for the factory default cfm sengs. When the cfm default se ngs are changed it will change the rela onship to the compressor speed that is shown in the table. In cooling mode compressor speeds 10-12 are only available when SuperBoost mode is selected at the thermostat. Factory sengs are at recommended G, L , H and Aux posi ons "G" may be located anywhere within the air ow table. "L" seng should be located within the boldface CFM range "H" seng MUST be located within the shaded CFM range "Aux" seng MUST be equal to or greater than "H" seng CFM is controlled within 5% up to the maximum ESP

Dual Power Supply Connections If two separate circuits are used to supply power to the auxiliary heat kit, the Installer will need to verify that each leg of the auxiliary heat circuit breakers are wired from the power supply correctly in order for the electric heat kit to operate properly. This can be done by measuring the supply side voltage of the auxiliary heat circuit breakers. Put a voltmeter on the L2 side of Circuit Breaker One and on the L2 side of Circuit Breaker Two. The voltmeter should read approximately 0 volts. If the meter reads high voltage, the auxiliary heat breakers need to be rewired so that breakers in the auxiliary heat kit match the wiring of the Disconnect Panel breakers. Meaning, Ll and L2 from one breaker in the disconnect panel must connect to 1:1 and L2 at one of the auxiliary heat circuit breakers and Ll and L2 from the other breaker in the disconnect panel must connect to 1:1 and L2 of the other auxiliary heat circuit breaker, making sure that the Ll and L2 from each disconnect breaker matches the 12I and L2 at each of the auxiliary heat breakers. Communicating Thermostat will connect to the COMM STAT (C R + -) power block PB3 in the air handler. A 4-conductor, 20AWG wire will need to connect from the TO ABC (C R + -) power block (PB2) in the Air Handler to the ABC P7(See detail 'A' on schematic) connection on the ABC board in the compressor section. Communicating Thermostat

WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 20 Note: On the AID Tool Configure Aurora Screen, confirm the AHB is added and communicating. Notes 1 - To operate in 208V mode replace the blue transformer wire connected to PB1-L2 with red transformer wire. 2 - Use manufacturer’s part number 19P592-01 (jumper bar assembly) when single source power is required. 3 - DIP switch 1 on SW1 must be set in the OFF position. 4- Low voltage wiring CLASS 2 BANG OLUFSEN Beosound Theatre Soundbar-fig2Air Handler Wiring Schematics cont. Variable Speed Pump (UPMXL 25-124) Variable Speed Flow Center With 1 – UPMXL 25-124 Pump WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 23 Variable Speed Flow Center With 2 – UPMXL 25-124 Pumps WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 24 Compressor Section Wiring Schematics cont. Aurora UPC WaterFurnace 700R11 Indoor Split Geothermal Heat Pump - Figure 25

ZS Sensor Information Zone Sensors can be wired in daisy chain as show or in a star or hybrid configuration. Maximum of 5 sensors per UPC. Maximum allowable load 210mA. See the UPC install manual for possible sensor combinations. BANG OLUFSEN Beosound Theatre Soundbar-fig3 Each ZS sensor must have a unique address, but the addresses do not need to be sequential. Use the DIP switches on the back of the ZS sensor to set an address from 0 to 4. (0 is the factory default.) Each DIP switch has the value shown in the figure to the left. Turn on as many DIP switches as you need so that their total value equals the address.

Notes 1. Use DIP Switches 5 – 8 to change communication protocol and DIP switches 1 – 2 to change BACnet baud rate Legend BANG OLUFSEN Beosound Theatre Soundbar-fig4 Fact ory Lo w Vo lt age Wiring Field Low V olta ge Wiring RJ45 Connector

Engineering Guide Specifications

General Furnish and install WaterFurnace Water Source Heat Pumps, as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in the schedule and the specifications that follow. The reverse cycle heating/cooling units shall be either suspended type with horizontal air inlet and discharge or floor mounted type with horizontal air inlet and vertical upflow, or downflow air discharge. Units shall be AHRI/ISO 13256-1 certified and listed by a nationally recognized safety-testing laboratory or agency, such as ETL Testing Laboratory. Each unit shall be computer runtested at the factory with conditioned water and operation verified to catalog data. Each unit shall be mounted on a pallet and shipped in a corrugated box or stretch-wrapped. The units shall be designed to operate with entering liquid temperature between 20°F and 120°F [-6.7°C and 48.9°C]. Casing and Cabinet The cabinet shall be fabricated from heavy-gauge galvanized steel and finished with corrosion-resistant powder coating. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. The interior shall be insulated with 1/2-inch thick, multi-density, cleanable aluminum foil coated glass fiber with edges sealed or tucked under flanges to prevent the introduction of glass fibers into the discharge air. Standard cabinet panel insulation must meet NFPA 90A requirements, air erosion and mold growth limits of UL- 181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements or unit(s) will not be accepted. Three compressor compartment access panels shall be ‘liftout’ removable. The front access panel shall be lift-out to provide easy access to the electrical/compressor section. The control box shall be hinged and removable to allow easy access to the compressor. The internal component layout shall provide for service access from the front side for restricted installations. The air handler shall be provided with two large access panels and shall be removable with supply and return ductwork in place. The internal components layout shall provide for major service with the unit in-place for restricted access installations. The blower assembly access shall be slide-out serviceable via a ‘works-in-a-drawer’ design. The cabinet shall be convertible to horizontal or downfl ow applications by reconfi guring the cabinet using only a nut driver. The unit shall be ‘zero clearance’ approved on any of its external surfaces. A duct collar shall be provided for fi eld installation on the supply air opening. The air handler shall be supplied with an integral return air fi lter rack (air fi lter is fi eld supplied).

Refrigerant Circuit All units shall contain a sealed refrigerant circuit including a hermetic motor-compressor, oil seperator, electronic expansion valve, reversing valve, coaxial tube water-torefrigerant heat exchanger, optional hot water generator coil, and service ports. Compressors shall be high-efficiency variable speed scroll type designed for heat pump duty and mounted on double vibration isolators. Compressor motors shall be permanent magnet type. All air handlers shall provide an electronic expansion valve, enhanced fi n and tube air-to-refrigerant heat exchanger of the “A” coil design. The fi nned tube coil shall be sized for low-face velocity and constructed of lanced aluminum fi ns bonded to aluminum tubes in a staggered pattern. The coil shall include a composite drain pan. Both electronic expansion valves shall provide proper superheat over the entire liquid temperature range with minimal “hunting.” Refrigerant to air heat exchangers shall utilize aluminum tube construction rated to withstand 600 psig (4135 kPa) refrigerant working pressure. Refrigerant to water heat exchangers shall be of copper (cupronickel optional) inner water tube and steel refrigerant outer tube design, rated to withstand 600 psig (4135 kPa) working refrigerant pressure and 450 psig (3101 kPa) working water pressure. All units shall have the source coaxial tube refrigerant-to water heat exchanger and the optional hot water generator coil coated with ThermaShield insulation. Refrigerant suction lines shall be insulated to prevent condensation at low liquid temperatures. Blower Motor and Assembly The blower shall be an oversized direct drive centrifugal type with a dynamically balanced wheel. The housing and wheel shall be designed for quiet low outlet velocity operation and of galvanized or galvalume steel construction. Tight blower housing geometry shall not be permitted. The blower housing shall be removable from the cabinet without disconnecting the supply air ductwork for servicing of the blower motor through a ‘works-in-a-drawer’ design. The high effi ciency blower motor shall be a variable speed ECM type. The blower motor shall be isolated from the housing by rubber grommets. The motor shall be perma- nently lubricated ball bearings and have thermal overload protection. Electrical A control box shall be located within the compressor and air handler compartments (air handler shall contain a 100VA transformer) and the compressor compartment shall contain a 24 Volt activated, 2 pole compressor contactor, circuit breakers for protecting loop pumps and compressor drive, removable terminal block for thermostat wiring, variable speed compressor drive and solid-state controller for complete unit operation. Electromechanical operation WILL NOT be accepted. Units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be communicating type and provide heating or cooling as required by the remote thermostat/sensor. An Aurora Advanced VS Control, a microprocessor based controller, interfaces with a digital communicating thermostat to monitor and control unit operation shall be provided. The control shall provide operational sequencing, blower speed

Engineering Guide Specifi cations cont.

control, blower failure, high and low pressure switch monitoring, freeze detection, hot water limit thermistor sensing, condensate overfl ow sensing, auxiliary heat staging, lockout mode control, hot water and loop pump control, LED status and fault indicators, fault memory, fi eld selectable options, compressor envelope management, energy consumption measurement, and accessory output. The fault signals shall be plain English text and displayed on the thermostat. The Aurora Advanced VS Control shall also feature an On Peak input signal for utility controlled demand programs, intelligent hot water generation with user adjustable temperature limit, loop pump linking for multiple units driving a common fl ow center and up to two optional home automation inputs to drive dedicated alarms for sump pump, security system, and smoke/CO2 or dirty air fi lter sensors. As standard, the energy, performance and refrigerant monitoring kits will provide real time data including total power consumption, entering and leaving water temperature, fl owrate and heat of extraction/rejection capacity data, refrigerant superheat and subcooling. The capability for communicating to advanced zoning packages with up to six zones shall also be provided with complete fault and information display on the zoning MasterStat. A detachable terminal block with screw terminals will be provided for field control wiring. All units shall have knockouts for entrance of low and line voltage wiring. The blower motor and control box shall be harness plug wired for easy removal. The air handler shall contain integral circuit breakers on all units employing 15 kW or 20 kW electric heat. The 100VA transformer shall be protected by internal circuit breaker. An Aurora Interface Diagnostic (AID) Tool shall communicate with the Aurora control allowing quick and easy access to setup, monitoring, and troubleshooting of any Aurora control. The device shall include the features of ECM airflow setup, VS pump and modulating water valve setup, fault description and history, manual operation capability, sensor readings, timings, and other diagnostic tools. Option: An Aurora Unitary Protocol Converter (UPC) shall be included that communicates directly with the Aurora Heat Pump Control and allows access/control of a variety of internal Aurora heat pump operations such as sensors, relay operation, faults and other information. In turn, the UPC shall convert the internal Aurora Modbus protocol to BACnet MS/TP protocol for communication over a HAS system. Additional individual unit configuration items such as ECM fan speeds or freeze detection settings shall be directly available over the HAS without the need for access to the actual heat pump. Piping Supply and return water connections shall be 1 in. [25.4 mm] FPT brass swivel fittings, which provide a union and eliminate the need for pipe wrenches and sealants when making field connections. The optional hot water generator shall have sweat type connections. All source water piping shall be insulated to prevent condensation at low liquid temperatures. Refrigeration connections shall be made using sweat copper joints. The air handler condensate connections shall be a 3/4 in. NPT. Options and Accessories Cupronickel Heat Exchanger An optional cupronickel water-to-refrigerant heat exchanger shall be provided. Hot Water Generator An optional ThermaShield coated heat reclaiming hot water generator coil of vented double-wall copper construction suitable for potable water shall be provided. The coil and hot water circulating pump shall be factory mounted inside the unit with integral electronic high limit temperature monitoring and external on/off switch. Hot water set point is selectable through the AID Tool. Thermostat (field-installed) A communicating auto-changeover electronic digital thermostat shall be provided. The thermostat shall offer variable speed heating and cooling staging with precise temperature control. An OFF-HEAT-AUTO-COOL-EMERG system switch, OFF-AUTO-INTERMITTENT blower switch, and indicating display shall be provided. The thermostat shall display in °F or °C. The thermostat shall provide real time energy consumption data of the unit. Color Touchscreen Thermostat (field-installed) A color touchscreen communicating auto-changeover electronic digital thermostat shall be provided. The thermostat shall offer variable speed heating and cooling staging with precise temperature control. An OFF-HEAT-AUTOCOOL-EMERG system switch, OFF-AUTO-INTERMITTENT blower switch, and indicating display shall be provided. The thermostat shall display in °F or °C. The thermostat shall provide real time and historical energy consumption data of the unit. Earth Loop Flow Center (field-installed) A self-contained module shall provide all liquid flow, fill and connection requirements for ground source closed loop systems up to 20 gpm. The pumps shall be wired to a power block located in the nearest unit. The heat pump units shall contain low voltage pump linking control so that two units may share one flow center.

Revision Guide

Pages: Description: Date: By:
Misc. Remove EEV, new part number revision -- JM
10 Updated line set length 12-Dec-20 MA
All Document created 26-Feb-20 MA

WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and specifications. Purchaser’s approval of this data set signifi es that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.

SD2703SNA 01/23WaterFurnace Logo

Documents / Resources

WaterFurnace 700R11 Indoor Split Geothermal Heat Pump [pdf] User Manual
700R11 Indoor Split Geothermal Heat Pump, 700R11, Indoor Split Geothermal Heat Pump, Geothermal Heat Pump

References

Documents - waterfurnace – 700R11
[pdf] User Manual Troubleshooting Guide
IM2703SNA indd meganamburn Installation Manual 7 Series 700R11 waterfurnace literature 7series |||
7 Series 700R11 Installation Manual 700R11 Indoor Split Geothermal Heat Pump R-410A Refrigerant 033, 042, 050 ton Variable Speed Installation Information Water Piping Connections Hot Water Generator Connections Electrical Startup Procedures Troubleshooting Preventive Maintenance IM2703SNA 01/23 ...
lang:it score:43 filesize: 9.74 M page_count: 86 document date: 2023-01-31
[pdf]
SD2703SNA indd meganamburn Submittal Data 7 Series 700R11 waterfurnace literature 7series |||
700R11 Indoor Split Geothermal Heat Pump 033, 042, 050 Variable Speed Submittal Data English Language/IP Units SD2703SNA 01/23 Contractor: Engineer: Project Name: P.O.: Unit Tag: 7 Series 700R11 033, 042, 050 ton 60Hz Unit Nomenclature Compressor Section 1 2 3 4-6 7 8 NV Z 042 * 1 Mod...
lang:en score:39 filesize: 4.48 M page_count: 42 document date: 2023-01-31
[pdf] Specifications Catalog
SC2703SNA indd meganamburn Specification Catalog 7 Series 700R11 waterfurnace literature 7series |||
Specification Catalog 7 Series 700R11 Indoor Split Geothermal Heat Pump 033, 042, 050 ton Variable Speed 7 SERIES 700R11 SPECIFICATION CATALOG Table of Contents Model Nomenclature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
lang:en score:35 filesize: 7.21 M page_count: 68 document date: 2023-01-31
[pdf] User Manual Troubleshooting Guide
IM2703SN indd jmondor 7 Series 700R11 Installation Manual WaterFurnace ant to water heat exchanger All source connections are swivel piping fittings see Figure 2 that accept 1 in male pipe threads MPT The connector has a rubber gasket seal similar hose which when mated the flush end of any threaded provides leak free without im2703sn waterfurnace literature 7series 00R11
7 Series 700R11 Installation Manual 700R11 Indoor Split Geothermal Heat Pump R-410A Refrigerant 033, 042, 050 ton Variable Speed Installation Information Water Piping Connections Hot Water Generator Connections Electrical Startup Procedures Troubleshooting Preventive Maintenance IM2703SN 01/21 ...
lang:it score:32 filesize: 9.13 M page_count: 84 document date: 2021-01-27
[pdf]
7 Series WaterFurnace This programmable thermostat can also provide instantaneous and 13 month energy monitoring history * The TPCC32U01 features 3 heat 2 cool stages   br2703sn waterfurnace literature 7series BR2703SN
Geothermal Comfort System 7 Series 700R11 The 7 Series 700R11 Indoor Split with Variable Capacity Technology The WaterFurnace 7 Series is quite possibly the most advanced heating and cooling system on the planet. It provides homeowners the ultimate in comfort and performance and represents our fin...
lang:en score:31 filesize: 3.71 M page_count: 9 document date: 2021-01-13
[pdf]
SD2703SN indd meganamburn sd2703sn waterfurnace literature 7series
700R11 Indoor Split Geothermal Heat Pump 033, 042, 050 Variable Speed Submittal Data English Language/IP Units SD2703SN 08/20 Contractor: Engineer: Project Name: P.O.: Unit Tag: 7 Series 700R11 033, 042, 050 ton 60Hz Unit Nomenclature Compressor Section 1 2 3 4-6 7 8 NV Z 042 * 1 Mode...
lang:en score:30 filesize: 3.36 M page_count: 40 document date: 2020-08-21
[pdf]
BR1510MW waterfurnace :80 literature collateral
Geothermal Comfort Systems All the Comforts of Home RESIDENTIAL PRODUCT LINE Smarter from the Grou ... nt way possible. In fact, in cooling mode, waste heat is recovered and hot water is free. 7 SERIES 700R11 Indoor Split Variable Capacity Indoor Split Unit Overall efficiency, performance features: ...
lang:en score:29 filesize: 34.3 M page_count: 9 document date: 2021-09-03
[pdf]
wf energystarcompliant waterfurnace
Certification of Geothermal Property Compliance WaterFurnace International, Incorporated, 9000 Conse ... m for Geothermal Heat Pumps. Specific models are listed below: Model Name 7 Series 700A11 7 Series 700R11 Indoor Split 5 Series 500A11/ ECM 5 Series 500A11/ PSC 5 Series 506A11 Outdoor Packaged 3 Ser...
lang:nl score:27 filesize: 101.22 K page_count: 1 document date: 2021-01-15
[pdf]
wf energystarcompliant 2020 waterfurnace
Certification of Geothermal Property Compliance WaterFurnace International, Incorporated, 9000 Conse ... m for Geothermal Heat Pumps. Specific models are listed below: Model Name 7 Series 700A11 7 Series 700R11 Indoor Split 5 Series 500A11/ ECM 5 Series 500A11/ PSC 5 Series 506A11 Outdoor Packaged 3 Ser...
lang:nl score:27 filesize: 75.25 K page_count: 1 document date: 2020-05-22
[pdf] Specifications Catalog
SC2703SN indd jmondor sc2703sn waterfurnace literature 7series
Specification Catalog 7 Series 700R11 Indoor Split Geothermal Heat Pump 033, 042, 050 ton Variable Speed 7 SERIES 700R11 SPECIFICATION CATALOG Table of Contents Model Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
lang:en score:26 filesize: 4.86 M page_count: 66 document date: 2021-01-27

tags: 700R11, 700R11 Indoor Split Geothermal Heat Pump, Geothermal Heat Pump, Indoor Split Geothermal Heat Pump, WaterFurnace,

Search Any Device: