GE C-Start™ Smart Switch Installation Guide

GE C-Start™ logoC-Start™ Smart Switch Installation Guide

WARNING: RISK OF ELECTRIC SHOCK This product installation requires handling 120-volt wiring. Follow each step carefully. If any concerns handling wiring, hire a qualified electrician. Ensure all work meets applicable local and national codes.

Simple DIY Setup

GE C-Start™ Smart Switch

Compatibility Requirements

Rating 120V AC 60Hz A neutral wire is required (Wire is usually white or grey) The ground wire is required (Wire is usually green, green with a yellow stripe or copper) GE C-Start™ Smart Switch - icon Wi-Fi 802.11 b/g/n @ 2.4 GHZ is required Works with halogen, incandescent and LED bulbs, including C by GE Smart Bulbs. LED up to 1.25 amps Incandescent/halogen up to 5 amps Motor up to 1/4HP

! IMPORTANT NOTE ON 3-WAY WIRING: Some lights have one wall switch, while others are controlled by two or more wall switches (such as stair lights, which have a switch at both the top and bottom of the stairs). If your lights have more than one switch (called a 3-way), we’ve created instructions for how to install and enable the capability. Visit cbyge.com/switch-support for 3-way installation instructions and how-to-videos.

Let’s Do It

INCLUDED GE C-Start™ Smart Switch - INCLUDED YOU’LL NEED GE C-Start™ Smart Switch - YOU’LL

You Got This!

And we’re here to help. For in-depth instructional videos and a guided tour through the installation, go to cbyge.com/switch-support. BEFORE YOU DO ANYTHING: Step 1 Turn Off The Power!

  1. Turn off the power for the switch located at the circuit breaker box.
  2. Test existing switch by toggling switch on/off, ensuring lights do not turn on.
  3. Now, follow these setup steps for a single gang switch.
GE C-Start™ Smart Switch - indicating the device STEP 2 Remove Your Old Switch
  1. Remove the existing wall plate and switch from the wall.
  2. Use voltage tester on the black wires to confirm power to the switch is off (recommended).
  3. Before disconnecting the wires from the wall, label each with the provided wire labels. Neutral and ground wires are required. If you don’t have either wire, the C by GE switch is not compatible.
  4. Disconnect wires and remove the existing switch.
GE C-Start™ Smart Switch - Wire Labels STEP 3 Connect The Wires
  1. Connect the neutral (white) wire on the switch to the neutral (white label) wire from the wall.
  2. Connect the line (black) wire on the switch to the line (black label) wire from the wall.
  3. Connect the load (red) wire on the switch with the load (red label) wire from the wall.
  4. Connect the ground (green) wire on the switch with the ground (green label) wire from the wall.
  5. Cap the 3-way/multi-way traveler wire (if applicable). For a 3-way switch setup, visit cbyge.com/switch-support Attention: Incorrectly connecting the Neutral or Ground wire from the wall to the Line or Load wire on the switch will damage the product.

GE C-Start™ Smart Switch - test connection

USING WIRE NUTS
  1. Insert wires into a wire nut.
  2. Turn wire nut clockwise.
  3. Pull gently on wires to test the connection.
GE C-Start™ Smart Switch - USING WIRE NUTS STEP 4 Fit Wires Into Wall Box Neatly push the wires back into the box, rotating the switch so it’s oriented according to the image. GE C-Start™ Smart Switch - according to the image STEP 5 Secure The Switch
  1. Using a Phillips screwdriver and the screws provided, secure the switch to the wall until level and flush.
  2. Screw on the faceplate bracket, then snap the faceplate cover onto the bracket.
GE C-Start™ Smart Switch - Secure The Switc STEP 6 Turn The Power Back On After the switch is secured and faceplate mounted, turn the power back on at the circuit breaker box. At the switch, the light ring will flash blue indicating the device is wired correctly and the device is in setup mode. GE C-Start™ Smart Switch - gang switch The light ring will continuously flash blue until the switch is added to the C by GE app. The light ring will flash red if the circuit is overloaded. Max load rating 150W LED and 450W incandescent/halogen. The light ring will not illuminate if wired incorrectly. IF LIGHTS DON’T TURN ON:
  1. Check that the air gap switch is depressed.
  2. Check that power to the switch is on at the breaker.
  3. Turn power off at the breaker, return to the switch to confirm the wires are securely and properly wired according to the installation guide.
  4. Go to cbyge.com/switch-support for more troubleshooting.

GE C-Start™ Smart Switch - IF LIGHTS DON’T

Congratulations! You’ve completed the Smart Switch installation. Next... GE C-Start™ Smart Switch - Next

Enable Your Voice Assistant

Amazon Alexa To set up, open the Alexa app, search for the C by GE skill, follow the setup instructions. Try this... Alexa, turn off the living room. Alexa, turn on the bedroom. Alexa set kitchen to 50%. Google Assistant To set up, open the Google Assistant or Google Home app, search for the C by GE action, follow the setup instructions. Try this... Hey Google, turn on the lights. Hey Google, good morning. Hey Google, I’m leaving.

Additional Information and Warnings FCC Compliance Statement Compliance Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

RF Exposure Information: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 8 inches during normal operation.

RF Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 8 inches from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

CAUTION To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle or motor-operated appliance or transformer-supplied appliance. For supply connections, use copper wire only rated at 75C.

Documents / Resources

GE C-Start™ Smart Switch [pdf] Installation Guide
GE, C-Start, Smart, Switch, Google Assistant

References


tags: C-Start, GE, Google Assistant, Smart, switch,