UNI-T UT890C True RMS Digital Multimeter User Manual

UNI-T-LOGO

UNI-T UT890C True RMS Digital Multimeter

UNI-T-UT890C-True-RMS-Digital-Multimeter-PRODUCT

Overview

The UT890C/D+ is a 6000-count digital multimeter with large LCD display and true RMS measurement functions. The maximum measuring capacitance is 100mF with fast response time of less than 12s; the NCV and continuity measurement have acousto-optic indication; UT890D+ has the (LIVE) function of measuring live and neutral wires. In addition, it is equipped with the automatic fuse blown detection and high voltage false detection.

Features

Accessories

Open the package box and take out the multimeter. Please double check whether the following items are missing or damaged.

If any of the above is missing or damaged, please contact your supplier immediately. Before using the meter, please read the safety instructions carefully.

Safety Instructions

Safety Standards

  1. The multimeter is designed according to IEC61010-1: 2010, 61010-2-030:2010, 61010-2-033:2012, 61326-1:2013 and 61326-2-2:2013 standards.
  2. The multimeter conforms to CAT II 1000V, CAT III 600V, double insulation IlI and material pollution grade 11.

Safety Instructions

  1. Do not use the meter if the rear cover is not covered up or it will pose a shock hazard!
  2. Before use. please check and make sure the insulation layer of the meter and test leads is in good condition without any damage or broken wires. Ifyou find the insulation layer of the meter housing is significantly damaged, or if you think the meter cannot function properly, do not use the meter.
  3. When using the meter, your fingers must be placed behind the finger guard ring of the test leads.
  4. Do not apply more than 1000V voltage between the meter terminal and the ground to prevent electric shock and damage to the meter.
  5. Be cautious when the measured voltage is higher than 60V (DC) or 30Vrms (AC) to avoid electric shock!
  6. The measured signal is not allowed to exceed the specified limit to prevent electric shock and damage to the meter!
  7. The range switch should be placed in the corresponding measuring setting.
  8. Never change the range setting when measuring to avoid damage to the meter!
  9. Do not change the internal circuit of the meter to avoid damage to the meter and user!
  10. The damaged fuse must be replaced with a fast-reaction one of the same specifications.
  11. When the UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (2)symbol appears on the LCD, please replace the battery in time to ensure measurement accuracy.
  12. Do not use or store the meter in high-temperature and high-humidity environments. The performance of the meter may be affected.
  13. Clean the meter casing with a damp cloth and mild detergent. Do not use abrasives or solvents!

Electrical Symbols

UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (1)

General Specifications

  1. Max voltage between the input terminal and the ground: 1000Vrms
  2. A 20A terminal: 16A H 250V fast-acting fuse (Ф6×32mm)
  3. A mA/MA terminal: 600mA H 250V fast-acting fuse (Ф6×32mm)
  4. Max display: 6099, "OL" appears when over range is detected, refresh rate is 3~4 times/s.
  5. Measuring range selection: Manual
  6. Backlight: Turned on by manual and turned off automatically after 30 seconds.
  7. Polarity: If negative polarity is input, the "_" symbol will be displayed
  8. Data hold function: The bottom left corner of the LCD displays " H".
  9. Low battery indication: The bottom left corner of the LCD displays " )".
  10. Acousto-optic indication: The continuity and NC measurement are accompanied by the beep and LED illumination indication.
  11. Internal battery: AAA battery 1.5V×2
  12. Operating temperature: 0 °C~40 °C (32 °F~104 °F)
    • Storage temperature: -10 °C-50 °C (14 °F~122 °F)
    • Relative humidity: 0 °C~below 30 °C s75%, 30 °C-40 °C ≤50%
    • Operating altitude: 0-2000m
  13. Dimensions: 183mm*88mm*56mm
  14. Weight: About 346g (including batteries)

External Structure (Picture 1)

  1. Protecting jacket
  2. LCD
  3. Functional buttons
  4. Transistor test port
  5. Range switch
  6. Input terminals
  7. Hook
  8. Test lead slot
  9. Battery cover
  10. HolderUNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (3)

Button Function

Operating Instructions

Please first check the internal AAA 1.5Vx2 batteries. If the battery is low when the device is turned on, the " " symbol will appear on the display. To ensure measurement accuracy, users need to replace batteries in time before use. Please also pay special attention to the warning sign " " beside the test lead terminals, which indicates that the measured voltage or current must not exceed the values listed on the device. DC/AC Voltage Measurement (Picture 2)

  1. Turn the range switch to the AC/DC voltage position;
  2. Insert the red test lead into the "VS" jack, black into the "COM" jack, and make the probes in contact with both ends of the measured voltage (parallel connection to the load);
  3. Read the test results on the display.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (4)
Note: The DCV measuring voltage should not be higher than 1000Vrms and ACV should not be higher than 750Vrms. Although it is possible to measure higher voltage, it may damage the meter and hurt the user! If the range of the measured voltage is unknown, select the maximum range and then accordingly reduce (If the LCD displays OL, it indicates that the voltage is over range). The input impedance of the meter is 10MQ. This load effect may cause measurement error when measuring the high impedance circuit. If the measured impedance is $10kQ, the error can be ignored ($0.1%). Be cautious to avoid electric shock when measuring high voltage. Test known voltage before use to confirm if the meter functions properly! Resistance Measurement (Picture 3)
  1. Turn the range switch to the resistance measurement position;
  2. Insert the red test lead into the "VQ" jack, black into the "COM" jack, and make the probes in contact with both ends of the measured resistance (parallel connection to the resistance);
  3. Read the test results on the display.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (5)
Note: Before measuring the resistance online, switch off the power supply of the circuit, and fully discharge all capacitors to avoid damage to the meter and user. Continuity Measurement (Picture 4)
  1. Turn the range switch to the continuity measurement position;
  2. Insert the red test lead into the "VO" jack, black into the "COM" jack, and make the probes in contact with the two test points;
  3. Measured resistance >51Q: The circuit is broken; buzzer makes no sound. Measured resistance ≤100: The circuit is in good conduction status; buzzer beeps continuously with a red LED indication.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (6)
  4. Note: • Before measuring the continuity online, switch off the power supply of the circuit, and fully discharge all capacitors to avoid damage to the meter and user.
Diode Measurement (Picture 4)
  1. Turn the range switch to the diode measurement position;
  2. Insert the red test lead into the "V" jack, black into the "COM" jack, and make the probes in contact with the two endpoints of the PN junction;
  3. If the diode is open or its polarity is reversed, the "OL" symbol will appear on the display. For the silicon PN junction, the normal value is generally about 500-800 mV (0.5 to 0.8 V). The moment the reading is displayed the buzzer beeps once. Long beep indicates the short circuit of the test lead.
Note: Transistor Magnification Measurement (hE) (Picture 5)
  1. Turn the range switch to the "hE" position;
  2. Insert the base (B), emitter (E) and collector (C) of the transistor (PP or NPN type) to be tested into the four-pin test port accordingly. The hE approximation of the transistor under test is shown on the display.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (7)
Capacitance Measurement (Picture 6)
  1. Turn the range switch to the capacitance measurement position;
  2. Insert the red test lead into the "VO" jack, black into the "COM" jack, and make the probes in contact with the two endpoints of the capacitance;
  3. Read the test results on the display. When there is no input, the meter displays a fixed value (intrinsic capacitance). For small capacitance measurement. this fixed value must be subtracted from the measured value to ensure measurement accuracy. Or users can choose the relative measurement function "A " (REL) to automatically subtract the intrinsic capacitance.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (8)
Note: If the measured capacitor is short-circuited or the capacitance exceeds the maximum range, the "OL" symbol will appear on the display. When measuring high capacitance, it is normal to take a few seconds to steady the readings. Before measuring, fully discharge all capacitors (especially for capacitors with high voltage) to avoid damage to the meter and user. AC/DC Measurement (Picture 7)
  1. Turn the range switch to the DC (AC) position;
  2. Insert the red test lead into the "mAuA" or "A" jack, black into the "COM" jack, and connect the test leads to the power supply or circuit to be tested in series;
  3. Read the test results on the display.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (9)
Note: Temperature Measurement (UT890C °C/°F Measurement, Picture 8)
  1. Turn the range switch to the temperature measurement position;
  2. Insert the plug of the K-type thermocouple into the meter, and fix the temperature sensing end of the probe on the object to be tested; read the temperature value on the display after it is steady.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (10)
Note: "OL" symbol appears when the meter is turned on. Only K-type thermocouple/ temperature sensor is applicable (The measured temperature should be less than 250 °C/482 °F). °F=°C*1.8+32 Frequency Measurement (Picture 9)
  1. Turn the range switch to the Hz position;
  2. Insert the red test lead into the "VS" jack, black into the "COM" jack, and connect the test leads to both ends of the signal source in parallel (The measurement range is 10Hz~10MHz);
  3. Read the test results on the display.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (11)
Note: Live or Neutral Wire Measurement (UT890D+) (Picture 10)
  1. Turn the range switch to the LIVE position;
  2. Insert the red test lead into the "VS" jack, make the black test lead suspended, and use the red test lead to touch the socket or bare wire to distinguish the live or neutral wire;
  3. When the neutral wire is detected, the "-...." state is displayed.
  4. When the voltage of AC field is about higher than 70 V, the measured object is identified as AC "live wire", and the LCD displays "LIVE" accompanied by acousto-optic indication.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (12)
Note:
  1. When measuring the LIVE function, in order to avoid the effect of the interference electric field of the COM input on the accuracy of distinguishing the live/neutral wire, please move the black test lead away from the COM input.
  2. When the LIVE function is applied to the measurement of dense high-voltage electric field, the accuracy of the meter to judge the "live wire" may be unstable. In this case, it should be judged by the LCD display and sound frequency together.
Non-contact AC Electric Field Sensing (Picture 11)
  1. To sense whether there is AC voltage or electromagnetic field in the space, please turn the range switch to (NCV) position;
  2. Bring the front end of the meter close to a charged object to start sensing. The LCD indicates the intensity of the electric field sensing by the segment,and the segment"." is displayed in five levels. The more the segments (up to four segments) are displayed, the higher the frequency of the beep. At the same time, the red LED flashes. As the electric field is measured, the buzzer and red LED synchronously change the frequency of beeping and flashing. The higher the electric field intensity is, the higher the frequency of the buzzer beeping and LED flashing, and vice versa.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (13)
  3. The diagram of the segment indicating the intensity of the electric field sensing is shown below.UNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (14)

Others

Technical Index Note: DCV Measurement
Range Resolution Accuracy
600. OmV 0.1mV ± (0. 5%+5 )
6 . 000V 0 . 001V ± (0 . 5 %+2)
60. oov 0 . 01V ± (0 . 5 %+2 )
600. ov 0. 1V ± (0. 5%+2 )
1000V 1V ± (0. 7%+5 )
Note: ACV Measurement
Range Resolution Accuracy
6.000V 0. 001V ± (1. 0% + 3 )
60.00V 0. 01V   ± (0. 8% + 3 )
600.0V 0. 1V
750V 1V ± (1. 0%+10)
Note:

Resistance Measurement

Range Resolution Accuracy
600.00 0. 10 ± ( 0. 8% + 5 )
6.000kO 0. 001k0     ± (0.8%+ 3 )
60.00kO 0. 01k0
600.0kO 0. 1k0
6.000MO 0.001MO
60.00MO 0. 01MO ± (3. 0%+10 )
Note: Continuity and Diode MeasurementUNI-T-UT890C-True-RMS-Digital-Multimeter-FIG-1 (16) Note: Overload protection: 1000Vrms (DC/AC) Capacitance Measurement
Range Resolution Accuracy
6.000nF 0.001nF In REL mode: ±(4.0%+10)
60. 00nF 0. 01nF   ± (4%+10)
600 . 0nF 0 . 1nF
6000µF 0. 001µF     ± (3%+10 )
60.00µF 0. 01µF
600 . 0µF 0 . 1µF
6. OOOmF 0. 001mF ± ( 5. 0%+10 )
60. OOmF 0.01mF   ± (10.0%)
100 . OmF 0. 1mF
Note: Temperature Measurement (UT890C)
Range Resolution Accuracy
  ·c   - 40~ 1000°C - 40~ 40°C   1·  c ± 3°C
> 40~ 500°C ± (1. 0%+3 )
>  500 ~ 1000 °C ± ( 2. 0 %+3 )
  "F   - 40 ~ 1832 °F - 4 0 ~ 104 ' F   1 °F ± 5 °F
>  104 ~ 932 °F ± ( 1 . 5 %+5 )
>  932 ~ 1832 °F ± (2 . 5 %+5 )
Note: DC Measurement
Range Resolution Accuracy
60. OOµA 0. 01µA     ± ( 0. 8%+ 8 )
600.0µA 0. 1µA
6.000mA 0.001mA
60. OOmA 0. 01mA
600. OmA 0.1mA ± ( 1 . 2 %+ 5 )
20. OOA 0. 01A ± ( 2 . 0 %+ 5 )
Note: AC Measurement
Range Resolution Accuracy
60. OOµA 0. 01µA     ± (1. 0%+12)
600.0µA 0. 1µA
6.000mA 0.001mA
60. OOmA 0. 01mA
600. OmA 0.1mA ± ( 2 . 0 %+ 3 )
20.OOA 0. 01A ± ( 3 . 0 %+5 )
Note: Frequency Measurement
Range Resolution Accuracy
9. 999Hz~ 9. 999MHz 0. 001Hz~ O. 001MHz ± (0. 1%+5 )
Note: Input amplitude:

Maintenance

General Maintenance

Battery/Fuse Replacement (Picture 12) Replace the battery immediately when the low battery symbol " " appears on the LCD, otherwise the measurement accuracy might be affected. Turn the range switch to the "OFF" position, remove the test leads from the input jacks, and take off the protecting jacket. Unscrew the screw on the battery cover with a screwdriver to replace the blown fuse. UNI-TREND TECHNOLOGY (CHINA) CO., LTD.

CONTACT

Documents / Resources

UNI-T UT890C True RMS Digital Multimeter [pdf] User Manual
UT890C True RMS Digital Multimeter, UT890C, True RMS Digital Multimeter, RMS Digital Multimeter, Digital Multimeter, Multimeter
Documents - uni-t – UT890C
[pdf] User Manual
Cuprins Dorina Manual de utilizare Multimetru digital ut890c uni t MIE0308 Teesa teesa ro manuale |||
Manual de utilizare multimetru MIE0308/MIE0309 I. GENERALITI Multimetrele UT890C/D sunt multimetre cu afisaj mare LCD si funcii de msurare RMS. Capacitatea maxim msurat este de 100 mF cu un timp de rspuns mai mic de 12 sec., msurarea NCV i msurarea de continuitate au indicaii optice i acustice, UT8...
lang:it score:36 filesize: 599.42 K page_count: 9 document date: 2019-11-12
[pdf] User Manual Instructions
110401105881X Pdf leírás2 Uni t webbolt UNI T UT890D ~ Digitális multiméter UT890C D English Manual uni hu userfiles webshop products attachments |||
Operating Manual I. General Introduction This brand new UT890C /D Operating Manual is a handheld 3-5/6 digit True RMS Digital Multi-meter featuring stable performance and high reliability. Its whole circuit design utilizes a large scale integrated circuit that uses ADC converter as its core and is f...
lang:en score:34 filesize: 2.38 M page_count: 2 document date: 2024-01-13
[pdf] User Manual
Cuprins Dorina Manual de utilizare Multimetru digital ut890d uni t MIE0428 Teesa teesa ro manuale |||
Manual de utilizare multimetru UT890C/D I. GENERALITI Multimetrele UT890C/D sunt multimetre cu afisaj mare LCD si funcii de msurare RMS. Capacitatea maxim msurat este de 100 mF cu un timp de rspuns mai mic de 12 sec., msurarea NCV i msurarea de continuitate au indicaii optice i acustice, UT890D a...
lang:it score:30 filesize: 642.99 K page_count: 9 document date: 2022-12-06
[pdf]
pl Miernik uniwersalny Uni T UT890C Lechpol B2B MIE0308 lechpol file 13727 |||
MIERNIK UNIWERSLANY UNI-T UT890C /D MIE0306 INSTRUKCJA OBSLUGI KWESTIE BEZPIECZESTWA Instrukcja obslugi Nie naley uywa miernika, jeeli klapka baterii jest otwarta. Grozi to poraeniem elektrycznym. Przelcznik trybu powinien by ustawiony do odpowiedniej pozycji. Przed uyciem naley upewni si, e...
lang:pl score:28 filesize: 4.06 M page_count: 10 document date: 2019-06-28
[pdf] User Manual
Cuprins Dorina Manual de utilizare Multimetru digital ut890d uni t MIE0309 Teesa teesa ro manuale |||
Manual de utilizare multimetru MIE0308/MIE0309 I. GENERALITI Multimetrele UT890C/D sunt multimetre cu afisaj mare LCD si funcii de msurare RMS. Capacitatea maxim msurat este de 100 mF cu un timp de rspuns mai mic de 12 sec., msurarea NCV i msurarea de continuitate au indicaii optice i acustice, UT8...
lang:it score:28 filesize: 599.42 K page_count: 9 document date: 2019-11-12
[pdf]
Miernik uniwersalny Uni T UT890C NCV Lechpol 2020 12 19 — ZAKRESY POMIAROWE Napięcie DC 600 mV 6 V 60 1000 ± 0 5% 2 AC 750 8% 3 miernik uni t ut890c ncv lechpol pl product 22460 |||
Miernik uniwersalny Uni-T UT890C NCV Marka: Uni-t Kod produktu: MIE0398 Kod EAN: 5901890056236 Opis techniczny ZAKRESY POMIAROWE: Napicie DC: 600 mV / 6 V / 60 V / 600 V / 1000 V 0,5 2 Napicie AC: 6 V / 60 V / 600 V / 750 V 0,8 3 Natenie prdu stalego DC: 60 uA / 600 uA / 6 mA / 60 mA / 600 mA ...
lang:pl score:28 filesize: 95.98 K page_count: 2 document date: 2022-01-29
[pdf] User Manual Quick Start Guide Guide Catalog
UNI T Catalog 2022 1 P C Schwick Mar 24 — Auto record me setup tool box UTi384M UTi640C English manual quick start guide Echo Thermal Imagers are more cost effec ve and schwick de 03 |||
No. 6, Industrial North 1st Road, Songshan Lake Park, Dongguan City, Guangdong Province Post Code: 5 ... Lus 003 www.uni-trend.com Models Page Digital Multimeters UT39A UT39C UT39E UT136B UT136C UT890C UT890D UT89X UT89XD UT89XE 057 057 057 070 070 076 076 061 061 061 DC voltage V...
lang:en score:28 filesize: 14.88 M page_count: 194 document date: 2021-10-12
[pdf]
LECHPOL ELECTRONIC S edc4 Declaratie de conformitate » MULTIMETRU DIGITAL UT890C NCV UNI T MIE0398 Global Electronic SRL global electronic ro |||
LECHPOL ELECTRONIC S.R.L. Resita, B-dul Republicii 5, ap.4 Caras-Severin J11/1142/2007 RO22976532 Te ... 7, RO22976532, asiguram, garantam si declaram pe propria raspundere ca produsul: MULTIMETRU DIGITAL UT890C NCV UNI-T cod produs MIE0398 la care se refera aceasta declaratie respecta cerintele esenti...
lang:it score:26 filesize: 73.91 K page_count: 2 document date: 2021-08-23
[pdf] Specifications Catalog
admin Catalogue UNI T UT890C Đồng Hồ Vạn Năng 1000V 20A True RMS ±0 5% IMALL imall vn 2022 02 |||
UT890C Digital Multimeter The UT890C/D 6000-count true RMS digital multimeters are designed with large LCD display. The maximum measurable capacitance is 100mF, with fast response time of less than 12s. The NCV and continuity measurement have acousto-optic indications. UT890D has a LIVE function f...
lang:en score:24 filesize: 356.42 K page_count: 3 document date: 2020-08-21
[pdf] Flyer
Downloads UNI T Meters Test Measurement Tools and Solutions UT890 Series Flyer meters uni trend ut890c d flyer wpdmdl 7206 refresh 62cf7581e0fcd1657763201 |||
UT890 SERIES True RMS Digital Multimeters The UT890C/D 6000-count true RMS digital mulmeters are designed with large LCD display. The maximum measurable capacitance is 100mF, with fast response me of less than 12s. The NCV and connuity measurement have acousto-opc indicaons. UT890D has a LIVE fun...
lang:en score:24 filesize: 982.06 K page_count: 1 document date: 2022-03-19
[pdf] User Manual
UT890C D English manual Uni T True RMS Digital Multimeter mme ae user dl 2023 06 |||
...
lang:en score:22 filesize: 5.45 M page_count: 2 document date: 2023-06-27
[pdf]
UNIVERZÁLNÍ METR UNI T UT890C NCV MIE0398 MIE0428 MIE0398CS filename* UTF 8 elektromarket cz media 4029 mie0398cs key ZGpmIyQwNUZfNDAyOQ |||
Pelozeno z polstina do cestina - www.onlinedoctranslator.com UNIVERZLN METR UNI-T UT890C NCV MIE0398 / MIE0428 UZIVATELSK MANUL BEZPECNOSTN PROBLMY Uzivatelsk manul Elektromr spluje pozadavky normy IEC61010-1: 2010; 61010-2-030: 2010; 61010-2-033: 2012; 61326-1: 2013 a 61326-2-2: 2013. Elektro...
lang:hr score:22 filesize: 2.77 M page_count: 7 document date: 2022-06-17
[pdf] Guide Catalog
Đồng hồ vạn năng UNI T UT18B PRO 1000VAC DC 10AAC SIEUTHITHIETBI COM VN 2024 Product Selection Guide Compressed version sieuthithietbi vn d cdn 56d5e434046953f30e93e691ca3085c231b61271 1645374 |||
Sales Contacts Europe Shawn Zhang Email: Shawn uni-trend.com WhatsAPP: 86 1730 1596 823 Tel: 44 75 ... 1000V 10A 10A 60M 100mF 10MHz -40C -1000C 6000 1m 005 meters.uni-trend.com Models UT890C Digital Multimeters UT890D UT892 UT89X UT89XD UT89XE DC voltage V AC voltage V DC...
lang:en score:21 filesize: 2.71 M page_count: 46 document date: 2023-12-07
[pdf] User Manual Datasheet
UT890C D English manual UNI T Digital Multimeter User Manual 2 1 Overview The is a 6000 count digital multimeter with large LCD display and true RMS measurement functions maximum measuring capacitance ut890c d english rcscomponents kiev ua datasheets uni trend uploadfile cloud General Meters
...
lang:en score:20 filesize: 6.7 M page_count: 2 document date: 2019-07-01
[pdf] User Manual
UT890C D English manual مولتی متر یونی تی UNI T مدل UT890D فروشگاه تکترونیکس 2084 orig tektronix ir Content media image 2024 04 |||
...
lang:en score:19 filesize: 6.47 M page_count: 2 document date: 2024-04-24
[pdf] Instructions
UT890C英文单页说明书 endb076 Instructions for Use IFU UNI T Multimeter Kit UT890C True RMS 6000Counts Volt Meter Ohmmeter Ac Dc Voltage Current Amp Capacitance Temperature hFE Diode Continuity Test NCV Automotive HVAC Tools Home Improvement B1bU83aTPlS m media amazon images I |||
f f ...
lang:en score:19 filesize: 3.61 M page_count: 2 document date: 2021-10-12
[pdf]
LPE Calin Declaratie de conformitate Multimetru digital ut890c ncv uni t MIE0398 Teesa teesa ro |||
DECLARAIA DE CONFORMITATE CE LECHPOL ELECTRONICS, societate cu rspundere limitat 08-400 Garwolin, strada Mitne 1 Garwolin Produs: multimetre universale Marca: UNI-T Model: M830x, M890x, UT51, UT52, UT53, UT54, UT55, UT56, UT70x, UT33x, UT20x, UT50x, UT58x, UT105, UT60x, UT107, UT71x, UT601, UT602, U...
lang:fr score:17 filesize: 137.01 K page_count: 1 document date: 2022-06-10
[pdf] Catalog
anbisolutions UNI T 26 sept 2022 — UT325 Contact Type Thermometer fast measurement reference Unit conversion Dual decoration DIY and other fields requiring accurate Catalog 09 |||
UNI-T Test and Measuring Instruments list S.NO. Model NO. Item Description Bar Code Ctn. Packin ... with resistance, capacitance, NCV, Continuity freq. 6935750589106 40 1000VDC 750VAC 20A UT890C UNI-T 6000count true RMS Digital 73 UT890C Industrial and Scientific Multimeter with Temp,...
lang:en score:17 filesize: 2.63 M page_count: 39 document date: 2022-09-21
[pdf]
100y tw TW 100Y COM M W OM 1 WWW 58 UNI T UT33B images file |||
WWWWWW.10W.100.Y10.0YC0.YC.OYC.MOCM.OTM.T.WT.WTW WWWWWWWWW.10W.10.100.Y10.0YC0.YC.OC.MOCM.OTM.T.WT.W ... .MW.0OMWW..YCWTT10W.MW.0OWW..YCWTT10W .100Y.C OM.T W W WW.1 00Y.C OM.T W UT890 Y.C .T W .1 .C .T UT890C /UT890D W.100 Y.COM .TW WWW .100Y .COM .TW IEC61010-1 IEC 61010-2-030 / ...
lang:i-klingon score:17 filesize: 6.05 M page_count: 12 document date: 2019-01-08
[pdf]
Miernik Uniwersalny Uni T UT890C nCV D MIE0398 MIE0428 Podłączyć przewody pomiarowe równolegle do testowanej ścieżki uwagi napięcie Dc nie może przekraczać 1000 V a ac 750 jeżeli jest znane spełnia wymagania zgodne z IEc61010 1 2010 61010 2 030 033 2012 61326 2013 oraz instrukcja miernik ut890 c d gotronik pl images
Miernik Uniwersalny Uni-T UT890C NCV/D MIE0398 / MIE0428 Instrukcja obslugi KWESTIE BEZPIECZESTWA Instrukcja obslugi Miernik spelnia wymagania zgodne z IEC61010-1:2010; 61010-2-030:2010; 61010-2-033:2012; 61326-1:2013 oraz 61326-2-2:2013. Miernik spelnia wymagania kategorii CAT II 1000 V, CA...
lang:pl score:17 filesize: 2.45 M page_count: 12 document date: 2020-06-25
[pdf] User Manual Specifications Catalog
admin Catalogue UNI T UT890D Đồng Hồ Vạn Năng 1000V 20A True RMS ±0 5% IMALL imall vn 2022 02 |||
UT890D Digital Multimeter The UT890C/D 6000-count true RMS digital multimeters are designed with large LCD display. The maximum measurable capacitance is 100mF, with fast response time of less than 12s. The NCV and continuity measurement have acousto-optic indications. UT890D has a LIVE function ...
lang:en score:15 filesize: 355.41 K page_count: 3 document date: 2020-08-21
[pdf] Guide Catalog
h ps linkedin company uni trend technology china limited Desktop level with high accuracy Wide test range UT625A 0 1μΩ~1000 0mΩ UT625B 1μΩ~2000 Stepping output current of each 10A 2025 Product Selection Guide Compressed version lemona lt Files Documents |||
Facebook hps://www.facebook.com/unitrend88/ YouTube hps://www.youtube.com/UniTrendTechnology Linke ... 10MHz -40C -1000C 6000 1m 005 meters.uni-trend.com Digital Multimeters Models UT890C UT890D UT892 UT89X UT89XD UT89XE DC voltage V AC voltage V DC current A AC curre...
lang:en score:14 filesize: 3.96 M page_count: 61 document date: 2024-12-11
[pdf] Datasheet
خرید مولتی متر دیجیتال یونیتی مدل UNI T UT890C فروشگاه اینترنتی سیانکو Digital Multimeter datasheet seeanco |||
UT890 SERIES TRMS DIGITAL MULTIMETERS ...
lang:en score:13 filesize: 315.99 K page_count: 1 document date: 2019-11-02
[pdf] Catalog
2022 UNI T Meters Catalog AMPE KÌM DÒNG AC KYORITSU KEW 8127 Ø24mm 100A » BẢO ANH NTH shopdoluong 12 |||
Sales Contacts Sales Director Rex Liu Email: rex uni-trend.com.cn Tel: 86 769 8572 3888-878 Oceania ... Lus 003 www.uni-trend.com Models Page Digital Multimeters UT39A UT39C UT39E UT136B UT136C UT890C UT890D UT89X UT89XD UT89XE 057 057 057 070 070 076 076 061 061 061 DC voltage V ...
lang:en score:13 filesize: 148.38 M page_count: 194 document date: 2021-09-28
[pdf] User Manual Catalog
threed contact clips cable management Three D Agencies 14 mai 2022 — easy installation on a bundle of Cables Wires or Hoses The double sided adhesive facilitates manual detachment and the application single base three d co za |||
INDEX Push-In Terminals 4 Screw Terminals 8 Markers 11 Cable Management 15 Solar Products ... ld LoZ ACV LCD Backlight Low Battery Indication Auto Power Off Display Count 6000 TRUE R M S UT890C - Multimeter DC Voltage: 1000 V AC Voltage: 750V AC/DC Current: 20A ACV Frequency: 10Hz -...
lang:en score:12 filesize: 58.53 M page_count: 80 document date: 2021-07-08
[pdf]
Arkusz specyfikacji UNI T Uni trend Cable and network tester UT681L RJ11 RJ45 LAN Tester Network Telephone Line Dual use LED Status Display NC HDMI Repair Tool Amazon pl D18hsGdF vL m media amazon images I |||
NEW PRODUCTS UTi260E/UTi320E Thermal Imagers Page 037 Resoluon: 256x192/320x240 Object Temperatur ... 003 www.uni-trend-hk.com Models Page Digital Multimeters UT39A UT39C UT39E UT136B UT136C UT890C UT890D UT89X UT89XD UT89XE 057 057 057 070 070 076 076 061 061 061 DC voltage V ...
lang:en score:11 filesize: 8.96 M page_count: 169 document date: 2023-08-08
[pdf]
Tabela porównawcza UNI T Uni trend Cable and network tester UT681L RJ11 RJ45 LAN Tester Network Telephone Line Dual use LED Status Display NC HDMI Repair Tool Amazon pl D1fIn9oXgUL m media amazon images I |||
Models Voltage and Continunity Testers UT22B-EU UT18C UT18D UT18E Voltage LED indicaons 12V ... 60M 100mF 10MHz -40C -1000C 6000 1m Model Selecon 004 Models Digital Multimeters UT890C UT890D UT892 UT89X UT89XD UT89XE DC voltage V AC voltage V DC current A AC curre...
lang:en score:11 filesize: 8.17 M page_count: 37 document date: 2023-08-07
[pdf]
08 2024 de 0824 wykaz urzadzen innych producentow api sonel pl media filer public ce 55 ce55ecd2 694a 486b 942e 687e794a3485 |||
HABEN SIE KEIN SONEL-GERT FR UNS IST DAS KEIN PROBLEM Im Rahmen der Akkreditierung kalibrieren wir ... UT55, UT58B, UT58D, UT60A, UT60C, UT61E, UT70A, UT70B, UT70D, UT71B, UT71D, UT71E, UT801, UT8802E, UT890C, UT890D , UT89X MY-68 DVM1400 VC97 VC270 AT-200, R-200, VC 850, VC250, VC960 20R 45217 DT890G...
lang:af score:10 filesize: 1.01 M page_count: 20 document date: 2024-08-06
[pdf]
08 2024 en 0824 wykaz urzadzen innych producentow api sonel pl media filer public 81 6f 816f2923 d6cf 4049 8b3d 1728794dc752 |||
DON T YOU HAVE A SONEL DEVICE IT S NOT A PROBLEM FOR US Within the scope of accreditation we calib ... UT55, UT58B, UT58D, UT60A, UT60C, UT61E, UT70A, UT70B, UT70D, UT71B, UT71D, UT71E, UT801, UT8802E, UT890C, UT890D , UT89X MY-68 DVM1400 VC97 VC270 08/2024 5 VOLTCRAFT WENS WIHA XTERME YATO YFE ZMU...
lang:af score:10 filesize: 956.96 K page_count: 20 document date: 2024-08-06
[pdf]
08 2024 pl 0824 wykaz urzadzen innych producentow api sonel media filer public c7 b6 c7b6f899 9851 4fef 8147 383affae63b2 |||
NIE MASZ URZDZENIA FIRMY SONEL TO DLA NAS NIE PROBLEM W zakresie akredytacji wzorcujemy rwnie przy ... UT55, UT58B, UT58D, UT60A, UT60C, UT61E, UT70A, UT70B, UT70D, UT71B, UT71D, UT71E, UT801, UT8802E, UT890C, UT890D , UT89X MY-68 DVM1400 VC97 VC270 AT-200, R-200, VC 850, VC250, VC960 20R 45217 DT890G...
lang:af score:10 filesize: 1.01 M page_count: 20 document date: 2024-08-06

tags: Digital Multimeter, Multimeter, RMS Digital Multimeter, True RMS Digital-Multimeter, UNI-T, UT890C, UT890C True RMS Digital Multimeter,

Search Any Device: