Electric Vehicle Supply Equipment
Star Charge Americas Corp
-
Model/Supplier Specific Specifications
EnergyStar Provided Specifications
Description | Value |
---|---|
DC-input or AC-input | AC-input |
Single Phase or Three Phase | Three Phase |
Product Configuration | Distributed Product Configuration |
Connector Type | Combined Charging System (CCS) |
Network Capability | Yes |
Network Connection Types Available | Gigabit Ethernet,Wi-Fi,Cellular |
Output Cord Length (ft.) | 23 |
Output Cord Gauge (AWG) | 1 |
Screen Area, if EVSE has high res display (in2) | 51.41 |
Maximum Measured Luminance of the High Res Display (candelas per m2) | 514.9 |
Automatic Brightness Control Capable? | No |
Connected Capable | No |
Auxiliary Product Features | High Resolution Display,Credit Card Reader,Radio Frequency Identification (RFID) |
Product Features | None |
Maximum Available Output Power | 320000 |
Maximum Nameplate Output Current (A) AC-Input | 500 |
Rated Input Voltage (V) AC-Input | 480 |
Number of Outputs | 2 |
Integral Battery Bank | No |
No Vehicle Mode Input Power (watts) AC-Input | 55.9 |
No Vehicle Mode Total Allowance (watts) | 157.06 |
No Vehicle Mode Power Factor AC-Input | 0.01 |
Partial On Mode Input Power (watts) AC-Input | 46.1 |
Partial On Mode Total Allowance (watts) | 157.06 |
Partial On Mode Power Factor AC-Input | 0.01 |
Idle Mode Input Power (watts) AC- Input | 170.2 |
Idle Mode Power Factor AC-Input | 0.02 |
Operation Mode: 25% Loading Condition Input Power in Cold Climate AC-Input | 82639.1 |
Operation Mode: 25% Loading Condition Output Power in Cold Climate AC-Input | 79747 |
Operation Mode: 50% Loading Condition Input Power in Cold Climate AC-Input | 164470 |
Operation Mode: 50% Loading Condition Output Power in Cold Climate AC-Input | 159895 |
Operation Mode: 75% Loading Condition Input Power in Cold Climate AC-Input | 247620 |
Operation Mode: 75% Loading Condition Output Power in Cold Climate AC-Input | 240154 |
Operation Mode: 50 kW Loading Condition Input Power in Cold Climate AC-Input | 51363.5 |
Operation Mode: 50 kW Loading Condition Output Power in Cold Climate AC-Input | 49465.7 |
Operation Mode: 150 kW Loading Condition Input Power in Cold Climate AC-Input | 154136 |
Operation Mode: 150 kW Loading Condition Output Power in Cold Climate AC-Input | 149573 |
Operation Mode: 100% Loading Condition Input Power in Cold Climate AC-Input | 330515 |
Operation Mode: 100% Loading Condition Output Power in Cold Climate AC-Input | 320349 |
Operation Mode: 100% Loading Condition Power Factor in Cold Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Temperate Climate AC-Input | 82244.7 |
Operation Mode: 25% Loading Condition Output Power in Temperate Climate AC-Input | 79776.3 |
Operation Mode: 50% Loading Condition Input Power in Temperate Climate AC-Input | 164421 |
Operation Mode: 50% Loading Condition Output Power in Temperate Climate AC-Input | 159325 |
Operation Mode: 75% Loading Condition Input Power in Temperate Climate AC-Input | 246766 |
Operation Mode: 75% Loading Condition Output Power in Temperate Climate AC-Input | 239183 |
Operation Mode: 50 kW Loading Condition Input Power in Temperate Climate AC-Input | 51090.9 |
Operation Mode: 50 kW Loading Condition Output Power in Temperate Climate AC-Input | 49522.5 |
Operation Mode: 150 kW Loading Condition Input Power in Temperate Climate AC-Input | 154183 |
Operation Mode: 150 kW Loading Condition Output Power in Temperate Climate AC-Input | 149540 |
Operation Mode: 100% Loading Condition Input Power in Temperate Climate AC-Input | 329780 |
Operation Mode: 100% Loading Condition Output Power in Temperate Climate AC-Input | 319396 |
Operation Mode: 100% Loading Condition Power Factor in Temperate Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Hot Climate AC-Input | 82342.3 |
Operation Mode: 25% Loading Condition Output Power in Hot Climate AC-Input | 79461.2 |
Operation Mode: 50% Loading Condition Input Power in Hot Climate AC-Input | 164146 |
Operation Mode: 50% Loading Condition Output Power in Hot Climate AC-Input | 159420 |
Operation Mode: 75% Loading Condition Input Power in Hot Climate AC-Input | 246486 |
Operation Mode: 75% Loading Condition Output Power in Hot Climate AC-Input | 238454 |
Operation Mode: 50 kW Loading Condition Input Power in Hot Climate AC-Input | 51066.1 |
Operation Mode: 50 kW Loading Condition Output Power in Hot Climate AC-Input | 49488.9 |
Operation Mode: 150 kW Loading Condition Input Power in Hot Climate AC-Input | 153030 |
Operation Mode: 150 kW Loading Condition Output Power in Hot Climate AC-Input | 148373 |
Operation Mode: 100% Loading Condition Input Power in Hot Climate AC-Input | 327346 |
Operation Mode: 100% Loading Condition Output Power in Hot Climate AC-Input | 316467 |
Operation Mode: 100% Loading Condition Power Factor in Hot Climate AC-Input | 0.99 |
Average Loading-Adjusted Efficiency (%) AC-Input | 0.97 |
Date Available On Market | 07/08/2024 |
Date Certified | 09/03/2024 |
Markets | United States, Canada |
CB Model Identifier | ES 1150661 DC3200AN147### 09032024101510 1010101 |
EnergyStar Provided Specifications
Description | Value |
---|---|
Date Available On Market | 07/08/2024 12:00:00 AM |
Date Certified | 09/03/2024 12:00:00 AM |
Markets | United States, Canada |
CB Model Identifier | ES 1150661 DC3200AN147### 09032024101510 1010101 |
Meets ENERGY STAR Most Efficient 2024 | No |
Device Name | Model | Certification Type | Certification Date |
---|---|---|---|
Electric Vehicle Supply Equipment | DC3200AN147### | Energy Star | 2024-09-03 |
Energy Star Certification Details
Descriptor | Details |
---|---|
Partner Name | Star Charge Americas Corp |
Model Name | Electric Vehicle Supply Equipment |
Other Model Details | ,,#=0-2 represents the different rated output current,0=400A,1=380A,2=400A+380A,#=1-3 represents the different DC connector deploy,1=With two Connectors,2=Only Left,3=Only Right,#=1-2 represents with or without POS terminal,1=with pos terminal |
Updated On | 2024-10-03 |
Last Update | 2024-10-04 |
DC-input or AC-input | AC-input |
Single Phase or Three Phase | Three Phase |
Product Configuration | Distributed Product Configuration |
Connector Type | Combined Charging System (CCS) |
Network Capability | Yes |
Network Connection Types Available | Gigabit Ethernet,Wi-Fi,Cellular |
Output Cord Length (ft.) | 23 |
Output Cord Gauge (AWG) | 1 |
Screen Area, if EVSE has high res display (in2) | 51.41 |
Maximum Measured Luminance of the High Res Display (candelas per m2) | 514.9 |
Automatic Brightness Control Capable? | No |
Connected Capable | No |
Auxiliary Product Features | High Resolution Display,Credit Card Reader,Radio Frequency Identification (RFID) |
Product Features | None |
Maximum Available Output Power | 320000 |
Maximum Nameplate Output Current (A) AC-Input | 500 |
Rated Input Voltage (V) AC-Input | 480 |
Number of Outputs | 2 |
Integral Battery Bank | No |
No Vehicle Mode Input Power (watts) AC-Input | 55.9 |
No Vehicle Mode Total Allowance (watts) | 157.06 |
No Vehicle Mode Power Factor AC-Input | 0.01 |
Partial On Mode Input Power (watts) AC-Input | 46.1 |
Partial On Mode Total Allowance (watts) | 157.06 |
Partial On Mode Power Factor AC-Input | 0.01 |
Idle Mode Input Power (watts) AC- Input | 170.2 |
Idle Mode Power Factor AC-Input | 0.02 |
Operation Mode: 25% Loading Condition Input Power in Cold Climate AC-Input | 82639.1 |
Operation Mode: 25% Loading Condition Output Power in Cold Climate AC-Input | 79747 |
Operation Mode: 50% Loading Condition Input Power in Cold Climate AC-Input | 164470 |
Operation Mode: 50% Loading Condition Output Power in Cold Climate AC-Input | 159895 |
Operation Mode: 75% Loading Condition Input Power in Cold Climate AC-Input | 247620 |
Operation Mode: 75% Loading Condition Output Power in Cold Climate AC-Input | 240154 |
Operation Mode: 50 kW Loading Condition Input Power in Cold Climate AC-Input | 51363.5 |
Operation Mode: 50 kW Loading Condition Output Power in Cold Climate AC-Input | 49465.7 |
Operation Mode: 150 kW Loading Condition Input Power in Cold Climate AC-Input | 154136 |
Operation Mode: 150 kW Loading Condition Output Power in Cold Climate AC-Input | 149573 |
Operation Mode: 100% Loading Condition Input Power in Cold Climate AC-Input | 330515 |
Operation Mode: 100% Loading Condition Output Power in Cold Climate AC-Input | 320349 |
Operation Mode: 100% Loading Condition Power Factor in Cold Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Temperate Climate AC-Input | 82244.7 |
Operation Mode: 25% Loading Condition Output Power in Temperate Climate AC-Input | 79776.3 |
Operation Mode: 50% Loading Condition Input Power in Temperate Climate AC-Input | 164421 |
Operation Mode: 50% Loading Condition Output Power in Temperate Climate AC-Input | 159325 |
Operation Mode: 75% Loading Condition Input Power in Temperate Climate AC-Input | 246766 |
Operation Mode: 75% Loading Condition Output Power in Temperate Climate AC-Input | 239183 |
Operation Mode: 50 kW Loading Condition Input Power in Temperate Climate AC-Input | 51090.9 |
Operation Mode: 50 kW Loading Condition Output Power in Temperate Climate AC-Input | 49522.5 |
Operation Mode: 150 kW Loading Condition Input Power in Temperate Climate AC-Input | 154183 |
Operation Mode: 150 kW Loading Condition Output Power in Temperate Climate AC-Input | 149540 |
Operation Mode: 100% Loading Condition Input Power in Temperate Climate AC-Input | 329780 |
Operation Mode: 100% Loading Condition Output Power in Temperate Climate AC-Input | 319396 |
Operation Mode: 100% Loading Condition Power Factor in Temperate Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Hot Climate AC-Input | 82342.3 |
Operation Mode: 25% Loading Condition Output Power in Hot Climate AC-Input | 79461.2 |
Operation Mode: 50% Loading Condition Input Power in Hot Climate AC-Input | 164146 |
Operation Mode: 50% Loading Condition Output Power in Hot Climate AC-Input | 159420 |
Operation Mode: 75% Loading Condition Input Power in Hot Climate AC-Input | 246486 |
Operation Mode: 75% Loading Condition Output Power in Hot Climate AC-Input | 238454 |
Operation Mode: 50 kW Loading Condition Input Power in Hot Climate AC-Input | 51066.1 |
Operation Mode: 50 kW Loading Condition Output Power in Hot Climate AC-Input | 49488.9 |
Operation Mode: 150 kW Loading Condition Input Power in Hot Climate AC-Input | 153030 |
Operation Mode: 150 kW Loading Condition Output Power in Hot Climate AC-Input | 148373 |
Operation Mode: 100% Loading Condition Input Power in Hot Climate AC-Input | 327346 |
Operation Mode: 100% Loading Condition Output Power in Hot Climate AC-Input | 316467 |
Operation Mode: 100% Loading Condition Power Factor in Hot Climate AC-Input | 0.99 |
Average Loading-Adjusted Efficiency (%) AC-Input | 0.97 |
Date Available On Market | 07/08/2024 |
Date Certified | 09/03/2024 |
Markets | United States, Canada |
CB Model Identifier | ES_1150661_DC3200AN147###_09032024101510_1010101 |