Electric Vehicle Supply Equipment
Star Charge Americas Corp
-
Model/Supplier Specific Specifications
EnergyStar Provided Specifications
Description | Value |
---|---|
DC-input or AC-input | AC-input |
Single Phase or Three Phase | Three Phase |
Product Configuration | Distributed Product Configuration |
Connector Type | Combined Charging System (CCS) |
Network Capability | Yes |
Network Connection Types Available | Gigabit Ethernet,Wi-Fi,Cellular |
Output Cord Length (ft.) | 23 |
Output Cord Gauge (AWG) | 1 |
Screen Area, if EVSE has high res display (in2) | 51.41 |
Maximum Measured Luminance of the High Res Display (candelas per m2) | 514.9 |
Automatic Brightness Control Capable? | No |
Connected Capable | No |
Auxiliary Product Features | High Resolution Display,Credit Card Reader,Radio Frequency Identification (RFID) |
Product Features | None |
Maximum Available Output Power | 280000 |
Maximum Nameplate Output Current (A) AC-Input | 500 |
Rated Input Voltage (V) AC-Input | 480 |
Number of Outputs | 2 |
Integral Battery Bank | No |
No Vehicle Mode Input Power (watts) AC-Input | 54.7 |
No Vehicle Mode Total Allowance (watts) | 152.3 |
No Vehicle Mode Power Factor AC-Input | 0.01 |
Partial On Mode Input Power (watts) AC-Input | 53.7 |
Partial On Mode Total Allowance (watts) | 152.3 |
Partial On Mode Power Factor AC-Input | 0.01 |
Idle Mode Input Power (watts) AC- Input | 172.6 |
Idle Mode Power Factor AC-Input | 0.02 |
Operation Mode: 25% Loading Condition Input Power in Cold Climate AC-Input | 72410 |
Operation Mode: 25% Loading Condition Output Power in Cold Climate AC-Input | 70244 |
Operation Mode: 50% Loading Condition Input Power in Cold Climate AC-Input | 144580 |
Operation Mode: 50% Loading Condition Output Power in Cold Climate AC-Input | 140481 |
Operation Mode: 75% Loading Condition Input Power in Cold Climate AC-Input | 216807 |
Operation Mode: 75% Loading Condition Output Power in Cold Climate AC-Input | 210636 |
Operation Mode: 50 kW Loading Condition Input Power in Cold Climate AC-Input | 51336 |
Operation Mode: 50 kW Loading Condition Output Power in Cold Climate AC-Input | 49840 |
Operation Mode: 150 kW Loading Condition Input Power in Cold Climate AC-Input | 154857 |
Operation Mode: 150 kW Loading Condition Output Power in Cold Climate AC-Input | 150367 |
Operation Mode: 100% Loading Condition Input Power in Cold Climate AC-Input | 289542 |
Operation Mode: 100% Loading Condition Output Power in Cold Climate AC-Input | 280563 |
Operation Mode: 100% Loading Condition Power Factor in Cold Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Temperate Climate AC-Input | 72179 |
Operation Mode: 25% Loading Condition Output Power in Temperate Climate AC-Input | 69956 |
Operation Mode: 50% Loading Condition Input Power in Temperate Climate AC-Input | 143818 |
Operation Mode: 50% Loading Condition Output Power in Temperate Climate AC-Input | 139504 |
Operation Mode: 75% Loading Condition Input Power in Temperate Climate AC-Input | 215061 |
Operation Mode: 75% Loading Condition Output Power in Temperate Climate AC-Input | 208958 |
Operation Mode: 50 kW Loading Condition Input Power in Temperate Climate AC-Input | 51200 |
Operation Mode: 50 kW Loading Condition Output Power in Temperate Climate AC-Input | 49671 |
Operation Mode: 150 kW Loading Condition Input Power in Temperate Climate AC-Input | 153413 |
Operation Mode: 150 kW Loading Condition Output Power in Temperate Climate AC-Input | 148655 |
Operation Mode: 100% Loading Condition Input Power in Temperate Climate AC-Input | 286989 |
Operation Mode: 100% Loading Condition Output Power in Temperate Climate AC-Input | 278201 |
Operation Mode: 100% Loading Condition Power Factor in Temperate Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Hot Climate AC-Input | 72017 |
Operation Mode: 25% Loading Condition Output Power in Hot Climate AC-Input | 69891 |
Operation Mode: 50% Loading Condition Input Power in Hot Climate AC-Input | 143540 |
Operation Mode: 50% Loading Condition Output Power in Hot Climate AC-Input | 139427 |
Operation Mode: 75% Loading Condition Input Power in Hot Climate AC-Input | 215319 |
Operation Mode: 75% Loading Condition Output Power in Hot Climate AC-Input | 209187 |
Operation Mode: 50 kW Loading Condition Input Power in Hot Climate AC-Input | 51254 |
Operation Mode: 50 kW Loading Condition Output Power in Hot Climate AC-Input | 49721 |
Operation Mode: 150 kW Loading Condition Input Power in Hot Climate AC-Input | 154172 |
Operation Mode: 150 kW Loading Condition Output Power in Hot Climate AC-Input | 149308 |
Operation Mode: 100% Loading Condition Input Power in Hot Climate AC-Input | 287896 |
Operation Mode: 100% Loading Condition Output Power in Hot Climate AC-Input | 278912 |
Operation Mode: 100% Loading Condition Power Factor in Hot Climate AC-Input | 0.99 |
Average Loading-Adjusted Efficiency (%) AC-Input | 0.97 |
Date Available On Market | 07/08/2024 |
Date Certified | 08/30/2024 |
Markets | United States, Canada |
CB Model Identifier | ES 1150661 DC2800AN147### 08302024104910 1010101 |
EnergyStar Provided Specifications
Description | Value |
---|---|
Date Available On Market | 07/08/2024 12:00:00 AM |
Date Certified | 08/30/2024 12:00:00 AM |
Markets | United States, Canada |
CB Model Identifier | ES 1150661 DC2800AN147### 08302024104910 1010101 |
Meets ENERGY STAR Most Efficient 2024 | No |
Device Name | Model | Certification Type | Certification Date |
---|---|---|---|
Electric Vehicle Supply Equipment | DC2800AN147### | Energy Star | 2024-08-30 |
Energy Star Certification Details
Descriptor | Details |
---|---|
Partner Name | Star Charge Americas Corp |
Model Name | Electric Vehicle Supply Equipment |
Other Model Details | ,,#=0-2 represents the different rated output current,0=400A,1=380A,2=400A+380A,#=1-3 represents the different DC connector deploy,1=With two Connectors,2=Only Left,3=Only Right,#=1-2 represents with or without POS terminal,1=with pos terminal |
Updated On | 2024-10-03 |
Last Update | 2024-10-04 |
DC-input or AC-input | AC-input |
Single Phase or Three Phase | Three Phase |
Product Configuration | Distributed Product Configuration |
Connector Type | Combined Charging System (CCS) |
Network Capability | Yes |
Network Connection Types Available | Gigabit Ethernet,Wi-Fi,Cellular |
Output Cord Length (ft.) | 23 |
Output Cord Gauge (AWG) | 1 |
Screen Area, if EVSE has high res display (in2) | 51.41 |
Maximum Measured Luminance of the High Res Display (candelas per m2) | 514.9 |
Automatic Brightness Control Capable? | No |
Connected Capable | No |
Auxiliary Product Features | High Resolution Display,Credit Card Reader,Radio Frequency Identification (RFID) |
Product Features | None |
Maximum Available Output Power | 280000 |
Maximum Nameplate Output Current (A) AC-Input | 500 |
Rated Input Voltage (V) AC-Input | 480 |
Number of Outputs | 2 |
Integral Battery Bank | No |
No Vehicle Mode Input Power (watts) AC-Input | 54.7 |
No Vehicle Mode Total Allowance (watts) | 152.3 |
No Vehicle Mode Power Factor AC-Input | 0.01 |
Partial On Mode Input Power (watts) AC-Input | 53.7 |
Partial On Mode Total Allowance (watts) | 152.3 |
Partial On Mode Power Factor AC-Input | 0.01 |
Idle Mode Input Power (watts) AC- Input | 172.6 |
Idle Mode Power Factor AC-Input | 0.02 |
Operation Mode: 25% Loading Condition Input Power in Cold Climate AC-Input | 72410 |
Operation Mode: 25% Loading Condition Output Power in Cold Climate AC-Input | 70244 |
Operation Mode: 50% Loading Condition Input Power in Cold Climate AC-Input | 144580 |
Operation Mode: 50% Loading Condition Output Power in Cold Climate AC-Input | 140481 |
Operation Mode: 75% Loading Condition Input Power in Cold Climate AC-Input | 216807 |
Operation Mode: 75% Loading Condition Output Power in Cold Climate AC-Input | 210636 |
Operation Mode: 50 kW Loading Condition Input Power in Cold Climate AC-Input | 51336 |
Operation Mode: 50 kW Loading Condition Output Power in Cold Climate AC-Input | 49840 |
Operation Mode: 150 kW Loading Condition Input Power in Cold Climate AC-Input | 154857 |
Operation Mode: 150 kW Loading Condition Output Power in Cold Climate AC-Input | 150367 |
Operation Mode: 100% Loading Condition Input Power in Cold Climate AC-Input | 289542 |
Operation Mode: 100% Loading Condition Output Power in Cold Climate AC-Input | 280563 |
Operation Mode: 100% Loading Condition Power Factor in Cold Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Temperate Climate AC-Input | 72179 |
Operation Mode: 25% Loading Condition Output Power in Temperate Climate AC-Input | 69956 |
Operation Mode: 50% Loading Condition Input Power in Temperate Climate AC-Input | 143818 |
Operation Mode: 50% Loading Condition Output Power in Temperate Climate AC-Input | 139504 |
Operation Mode: 75% Loading Condition Input Power in Temperate Climate AC-Input | 215061 |
Operation Mode: 75% Loading Condition Output Power in Temperate Climate AC-Input | 208958 |
Operation Mode: 50 kW Loading Condition Input Power in Temperate Climate AC-Input | 51200 |
Operation Mode: 50 kW Loading Condition Output Power in Temperate Climate AC-Input | 49671 |
Operation Mode: 150 kW Loading Condition Input Power in Temperate Climate AC-Input | 153413 |
Operation Mode: 150 kW Loading Condition Output Power in Temperate Climate AC-Input | 148655 |
Operation Mode: 100% Loading Condition Input Power in Temperate Climate AC-Input | 286989 |
Operation Mode: 100% Loading Condition Output Power in Temperate Climate AC-Input | 278201 |
Operation Mode: 100% Loading Condition Power Factor in Temperate Climate AC-Input | 0.99 |
Operation Mode: 25% Loading Condition Input Power in Hot Climate AC-Input | 72017 |
Operation Mode: 25% Loading Condition Output Power in Hot Climate AC-Input | 69891 |
Operation Mode: 50% Loading Condition Input Power in Hot Climate AC-Input | 143540 |
Operation Mode: 50% Loading Condition Output Power in Hot Climate AC-Input | 139427 |
Operation Mode: 75% Loading Condition Input Power in Hot Climate AC-Input | 215319 |
Operation Mode: 75% Loading Condition Output Power in Hot Climate AC-Input | 209187 |
Operation Mode: 50 kW Loading Condition Input Power in Hot Climate AC-Input | 51254 |
Operation Mode: 50 kW Loading Condition Output Power in Hot Climate AC-Input | 49721 |
Operation Mode: 150 kW Loading Condition Input Power in Hot Climate AC-Input | 154172 |
Operation Mode: 150 kW Loading Condition Output Power in Hot Climate AC-Input | 149308 |
Operation Mode: 100% Loading Condition Input Power in Hot Climate AC-Input | 287896 |
Operation Mode: 100% Loading Condition Output Power in Hot Climate AC-Input | 278912 |
Operation Mode: 100% Loading Condition Power Factor in Hot Climate AC-Input | 0.99 |
Average Loading-Adjusted Efficiency (%) AC-Input | 0.97 |
Date Available On Market | 07/08/2024 |
Date Certified | 08/30/2024 |
Markets | United States, Canada |
CB Model Identifier | ES_1150661_DC2800AN147###_08302024104910_1010101 |